silicon has been researched along with Adenoma* in 3 studies
1 trial(s) available for silicon and Adenoma
Article | Year |
---|---|
Treatment accuracy of fractionated stereotactic radiotherapy.
To assess the geometric accuracy of the delivery of fractionated stereotactic radiotherapy (FSRT) for brain tumours using the Gill-Thomas-Cosman (GTC) relocatable frame. Accuracy of treatment delivery was measured via portal images acquired with an amorphous silicon based electronic portal imager (EPI). Results were used to assess the existing verification process and to review the current margins used for the expansion of clinical target volume (CTV) to planning target volume (PTV).. Patients were immobilized in a GTC frame. Target volume definition was performed on localization CT and MRI scans and a CTV to PTV margin of 5mm (based on initial experience) was introduced in 3D. A Brown-Roberts-Wells (BRW) fiducial system was used for stereotactic coordinate definition. The existing verification process consisted of an intercomparison of the coordinates of the isocentres and anatomy between the localization and verification CT scans. Treatment was delivered with 6 MV photons using four fixed non-coplanar conformal fields using a multi-leaf collimator. Portal imaging verification consisted of the acquisition of orthogonal images centred through the treatment isocentre. Digitally reconstructed radiographs (DRRs) created from the CT localization scans were used as reference images. Semi-automated matching software was used to quantify set up deviations (displacements and rotations) between reference and portal images.. One hundred and twenty six anterior and 123 lateral portal images were available for analysis for set up deviations. For displacements, the total errors in the cranial/caudal direction were shown to have the largest SD's of 1.2 mm, while systematic and random errors reached SD's of 1.0 and 0.7 mm, respectively, in the cranial/caudal direction. The corresponding data for rotational errors (the largest deviation was found in the sagittal plane) was 0.7 degrees SD (total error), 0.5 degrees (systematic) and 0.5 degrees (random). The total 3D displacement was 1.8 mm (mean), 0.8 mm (SD) with a range of 0.3-3.9 mm.. Portal imaging has shown that the existing verification and treatment delivery techniques currently in use result in highly reproducible setups. Random and systematic errors in the treatment planning and delivery chain will always occur, but monitoring and minimising them is an essential component of quality control. Portal imaging provides fast and accurate facility for monitoring patients on treatment and the results of this study have shown that a reduction in CTV to PTV margin from 5 to 4 mm (resulting in a considerable increase in the volume of normal tissue sparing) could be made. Topics: Adenoma; Craniopharyngioma; Dose Fractionation, Radiation; Humans; Immobilization; Magnetic Resonance Imaging; Meningeal Neoplasms; Meningioma; Neuroma, Acoustic; Photons; Pituitary Neoplasms; Radiotherapy; Sensitivity and Specificity; Silicon; Stereotaxic Techniques; Tomography, X-Ray Computed | 2005 |
2 other study(ies) available for silicon and Adenoma
Article | Year |
---|---|
A subchronic inhalation toxicity study in rats exposed to silicon carbide whiskers.
To determine whether inhaled silicon carbide whiskers (SiC) cause lung damage in rats, four groups (50 males/50 females each) of rats were exposed to air only or to one of three concentrations of SiC 6 hr/day, 5 days/week for 13 weeks. Half (25 males/25 females/group) were euthanized at the end of exposure, the remainder 26 weeks later. Mean concentrations were 0, 630, 1746, and 7276 SiC whiskers/ml (0.09, 3.93, 10.7, and 60.5 mg/m3). Although there were no concentration-related changes in body weight, clinical chemistry, or hematological data attributable to SiC, lung weights were increased in the high concentration exposure group at both euthanization times. In all whisker-exposed groups, after 13 weeks of exposure, the incidence of the following lung and lymph node lesions was higher than in controls: inflammatory lesions; bronchiolar, alveolar, and pleural wall thickening; focal pleural fibrosis in lung; and reactive lymphoid hyperplasia in bronchial and mediastinal lymph nodes. After 26 weeks of recovery, lung inflammatory lesions had decreased and fewer rats had enlarged lymph nodes, but the incidence of alveolar wall thickening, focal pleural wall thickening, and adenomatous hyperplasia of lung had increased further. Incidence and severity appeared to be dose-related. Therefore, until longer term studies are undertaken and it is established whether the above observed lesions will progress to more severe pathological entities, it is prudent to adopt stringent handling procedures for silicon carbide whiskers. Topics: Adenoma; Animals; Carbon; Carbon Compounds, Inorganic; Female; Lung; Lung Neoplasms; Lymph Nodes; Male; Microscopy, Electron, Scanning; Organ Size; Pleura; Rats; Rats, Inbred Strains; Silicon; Silicon Compounds | 1991 |
Tumor response in strain A mice exposed to silylating compounds used for gas-liquid chromatography.
Six reagents used to silylate, alkylate, or acylate compounds for ease of identification on gas chromatographic columns significantly increased the frequency of lung tumors in A/He mice. Topics: Acetamides; Adenoma; Alkylating Agents; Animals; Chromatography, Gas; Female; Imidazoles; Indicators and Reagents; Lung Neoplasms; Male; Mice; Mice, Inbred A; Neoplasms, Experimental; Silicon; Triazenes | 1975 |