Page last updated: 2024-08-25

lead and dithizone

lead has been researched along with dithizone in 36 studies

Research

Studies (36)

TimeframeStudies, this research(%)All Research%
pre-199021 (58.33)18.7374
1990's0 (0.00)18.2507
2000's5 (13.89)29.6817
2010's10 (27.78)24.3611
2020's0 (0.00)2.80

Authors

AuthorsStudies
Hamilton, EI1
Eller, PM; Haartz, JC1
Danscher, G; Fjerdingstad, E; Fjerdingstad, EJ1
Baudot, P; Livertoux, MH; Monal, JL; Truhaut, R1
Gagliano-Candela, R; Gagliardi, T; Napoli, S1
Lerner, S1
Hancock, S; Slater, A1
Diehl, H; Ferreira da Silva, D1
Gonzalez Moreno, P; Gonzalez-Fernandez, E1
Blakemore, WM; Pounds, JG1
Legedź, E; Masłowska, J1
Chisolm, JJ1
ELKINS, HB1
MOKRANJAC, MS; RADMIC, S1
BESSMAN, SP; LAYNE, EC1
JAULMES, P1
HOSOKAWA, A; YOSHIDA, K; YOSHIDA, S1
MESCHIA, E; ZURLO, N1
PORTHEINE, F; ZIMMERMANN, H1
LANDRY, AS1
Chen, JR; Shen, YQ; Xiao, SM1
Debán, L; Tascón, ML; Vázquez, MD1
Ahmed, MJ; Bhanger, MI; Khan, H1
Manikandan, S; Rajesh, N1
Bai, H; Xiao, J; Xie, G; Zhou, Q1
Chisvert, A; Liawruangrath, S; Ruengsitagoon, W1
LEIBOWITZ, A; YOUNG, RS1
Wan, Q; Wang, X; Yang, N; Yu, F; Zhu, L1
Chen, L; Deng, J; Gu, Z; Kang, X; Lu, Z; Wang, Y1
Gao, S; Li, J; Ma, J; Wang, Y; Zang, X1
Ma, H; Rong, X; Tao, G; Zhao, Q1
Babadi, FF; Zargoosh, K1
Anari-Anaraki, M; Nezamzadeh-Ejhieh, A1
Mesquita, RBR; Rangel, AOSS; Santos, IC1
Ahmadvand, P; Amini, MM; Behbahani, A; Moghadam Zadeh, HR; Sayar, O1

Reviews

2 review(s) available for lead and dithizone

ArticleYear
Review of the chemical elements and environmental chemistry--strategies and tactics.
    The Science of the total environment, 1976, Volume: 5, Issue:1

    Topics: Air Pollutants; Air Pollution; Animals; Dithizone; Electron Probe Microanalysis; Environment Design; Environmental Pollutants; Humans; Laboratories; Lead; Mass Spectrometry; Monitoring, Physiologic; Soil Pollutants; Spectrometry, Gamma; United Kingdom; Water Pollution, Chemical; Zinc

1976
Evolution of the management and prevention of childhood lead poisoning: dependence of advances in public health on technological advances in the determination of lead and related biochemical indicators of its toxicity.
    Environmental research, 2001, Volume: 86, Issue:2

    Topics: Chelating Agents; Child; Child Welfare; Child, Preschool; Dithizone; Electrochemistry; Humans; Lead; Lead Poisoning; Mass Screening; Public Health; Spectrophotometry, Atomic

2001

Other Studies

34 other study(ies) available for lead and dithizone

ArticleYear
A study of methods for the determination of lead and cadmium.
    American Industrial Hygiene Association journal, 1977, Volume: 38, Issue:3

    Topics: Animals; Cadmium; Dithizone; Evaluation Studies as Topic; Filtration; Graphite; Lead; Methods; Spectrophotometry, Atomic; Swine; Tantalum

1977
Changes in zinc and lead content of rat hippocampus and whole brain following intravital dithizone treatment as determined by flameless atomic absorption spectrophotometry.
    Brain research, 1977, Jul-15, Volume: 130, Issue:2

    Topics: Animals; Azo Compounds; Brain Chemistry; Dithizone; Hippocampus; Lead; Rats; Spectrophotometry, Atomic; Zinc

1977
[Identification of toxic metals after extraction and thin-layer chromatograpy of their dithizonates. Toxicological applications (author's transl)].
    Journal of chromatography, 1976, Nov-17, Volume: 128, Issue:1

    Topics: Azo Compounds; Cadmium; Chromatography, Thin Layer; Cobalt; Copper; Dithizone; Feces; Humans; Lead; Lead Poisoning; Mercury; Mercury Poisoning; Metals; Nickel; Silver; Toxicology; Zinc

1976
[Lead detection and measurement in biological fluids by means of anodic stripping voltammetry (author's transl)].
    Lavoro umano, 1976, Volume: 28, Issue:3

    Topics: Body Fluids; Dithizone; Electrochemistry; Humans; Lead; Lead Poisoning; Methods

1976
Blood lead analysis - precision and stability.
    Journal of occupational medicine. : official publication of the Industrial Medical Association, 1975, Volume: 17, Issue:3

    Topics: Accreditation; Blood Chemical Analysis; Dithizone; Hematocrit; Humans; Laboratories; Lead; Methods; Preservation, Biological; United States

1975
A specific method for the determination of trace concentrations of tetramethyl- and tetraethyllead vapours in air.
    The Analyst, 1975, Volume: 100, Issue:1191

    Topics: Air Pollutants; Dithizone; Lead; Methods; Organometallic Compounds; Trace Elements; Volatilization

1975
Analytical guide: lead and its inorganic compounds.
    American Industrial Hygiene Association journal, 1975, Volume: 36, Issue:9

    Topics: Dithizone; Lead; Methods; Spectrophotometry, Atomic

1975
Metabolism of tetraorganolead compounds by rat-liver microsomal mono-oxygenase. I. Analytical methods for quantitative determination of dealkylation products.
    Xenobiotica; the fate of foreign compounds in biological systems, 1983, Volume: 13, Issue:10

    Topics: Animals; Dealkylation; Dithizone; Lead; Male; Methods; Microsomes, Liver; Organometallic Compounds; Oxygenases; Rats; Rats, Inbred Strains; Tetraethyl Lead

1983
Screening analysis for lead in whole blood and urine by Delves cup method using quality control samples. Comparison with the dithizone method.
    Industrial health, 1983, Volume: 21, Issue:2

    Topics: Colorimetry; Dithizone; Humans; Lead; Lead Poisoning; Quality Control; Spectrophotometry, Atomic

1983
The potential laboratory health hazard of 210Pb and a simple procedure for separation of 210Pb from the daughters 210Bi and 210Po.
    Toxicology letters, 1981, Volume: 9, Issue:4

    Topics: Bismuth; Dithizone; Humans; Laboratories; Lead; Polonium; Radioisotopes; Safety; Scintillation Counting

1981
[Comparison of methods of determining trace amounts of lead (II) in dyes and cosmetics].
    Roczniki Panstwowego Zakladu Higieny, 1981, Volume: 32, Issue:4

    Topics: Coloring Agents; Cosmetics; Dithizone; Drug Contamination; Lead; Polarography; Spectrophotometry; Spectrophotometry, Atomic

1981
Notes on determination of lead by dithizone method.
    American Industrial Hygiene Association quarterly, 1953, Volume: 14, Issue:2

    Topics: Air Pollution; Body Fluids; Dithizone; Lead; Urine

1953
[Contribution to the problem of determination of lead in the blood].
    Acta pharmaceutica Jugoslavica, 1953, Volume: 3, Issue:4

    Topics: Blood; Dithizone; Humans; Lead

1953
A rapid procedure for the determination of lead in blood or urine in the presence of organic chelating agents.
    The Journal of laboratory and clinical medicine, 1955, Volume: 45, Issue:1

    Topics: Body Fluids; Chelating Agents; Dithizone; Health Services; Humans; Lead; Learning

1955
[Lead determination in blood, wine, etc. by dithizone method].
    Journal de medecine de Bordeaux et du Sud-Ouest, 1957, Volume: 134, Issue:5

    Topics: Dithizone; Lead; Wine

1957
On the microdetermination of lead by dithizone method with special reference to contamination with reagents used for determination.
    Mie medical journal, 1961, Volume: 11

    Topics: Dithizone; Drug Contamination; Indicators and Reagents; Lead

1961
[Microdetermination of lead in air and biological materials by the dithizone titration method].
    La Medicina del lavoro, 1954, Volume: 45, Issue:12

    Topics: Air Pollution; Dithizone; Lead

1954
[Experience and results in the determination and evaluation of the lead content in 3000 blood samples].
    Klinische Wochenschrift, 1955, May-15, Volume: 33, Issue:19-20

    Topics: Blood; Dithizone; Humans; Lead

1955
Optimum range for maximum accuracy in biological lead analyses by dithizone.
    Industrial health monthly, 1951, Volume: 11, Issue:7

    Topics: Dithizone; Lead; Photometry

1951
[Determination of lead in water samples by graphite furnace atomic absorption spectrometry after cloud point extraction with dithizone].
    Guang pu xue yu guang pu fen xi = Guang pu, 2006, Volume: 26, Issue:5

    Topics: Dithizone; Environmental Monitoring; Lead; Spectrophotometry, Atomic; Water Pollutants, Chemical

2006
Determination of Pb(II) with a dithizone-modified carbon paste electrode.
    Journal of environmental science and health. Part A, Toxic/hazardous substances & environmental engineering, 2006, Volume: 41, Issue:12

    Topics: Calibration; Carbon; Dithizone; Electrodes; Industrial Waste; Lead; Soil Pollutants

2006
A rapid spectrophotometric method for the determination of trace level lead using 1,5-diphenylthiocarbazone in aqueous micellar solutions.
    Analytical sciences : the international journal of the Japan Society for Analytical Chemistry, 2007, Volume: 23, Issue:2

    Topics: Cetrimonium; Cetrimonium Compounds; Chelating Agents; Dithizone; Fresh Water; Industrial Waste; Lead; Micelles; Sensitivity and Specificity; Spectrophotometry, Ultraviolet; Surface-Active Agents; Water Pollutants, Chemical

2007
Spectrophotometric determination of lead after preconcentration of its diphenylthiocarbazone complex on an Amberlite XAD-1180 column.
    Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy, 2008, Volume: 70, Issue:4

    Topics: Adsorption; Dithizone; Hydrogen-Ion Concentration; Industry; Ions; Lead; Resins, Synthetic; Vibration; Water Pollutants; Water Supply; X-Ray Diffraction

2008
Temperature-controlled ionic liquid-liquid-phase microextraction for the pre-concentration of lead from environmental samples prior to flame atomic absorption spectrometry.
    Talanta, 2010, Mar-15, Volume: 80, Issue:5

    Topics: Centrifugation; Chemical Fractionation; Dithizone; Environmental Monitoring; Fresh Water; Hydrogen-Ion Concentration; Ionic Liquids; Lead; Limit of Detection; Spectrophotometry, Atomic; Temperature

2010
Flow injection spectrophotometric determination of lead using 1,5-diphenylthiocarbazone in aqueous micellar.
    Talanta, 2010, Apr-15, Volume: 81, Issue:1-2

    Topics: Absorption; Color; Dithizone; Flow Injection Analysis; Lead; Micelles; Reproducibility of Results; Sodium Dodecyl Sulfate; Spectrophotometry; Sulfuric Acids; Time Factors; Water

2010
The determination of lead in copper, nickel and cobalt by dithizone.
    The Analyst, 1946, Volume: 71, Issue:847

    Topics: Cobalt; Copper; Dithizone; Humans; Lead; Nickel

1946
Bucky-gel coated glassy carbon electrodes, for voltammetric detection of femtomolar leveled lead ions.
    Talanta, 2010, Oct-15, Volume: 82, Issue:5

    Topics: Cations; China; Dithizone; Elasticity; Electrochemical Techniques; Electrodes; Environmental Monitoring; Fresh Water; Gels; Imidazoles; Ionic Liquids; Lead; Limit of Detection; Nanotubes, Carbon; Reproducibility of Results; Water Pollutants, Chemical

2010
A nanofiber functionalized with dithizone by co-electrospinning for lead (II) adsorption from aqueous media.
    Journal of hazardous materials, 2011, Nov-30, Volume: 196

    Topics: Adsorption; Dithizone; Electrochemical Techniques; Equipment Design; Lead; Microscopy, Electron, Scanning; Molecular Structure; Nanofibers; Rotation; Solid Phase Extraction; Surface Properties; Water Pollutants, Chemical; Water Purification

2011
Graphene-based solid-phase extraction combined with flame atomic absorption spectrometry for a sensitive determination of trace amounts of lead in environmental water and vegetable samples.
    Analytica chimica acta, 2012, Feb-24, Volume: 716

    Topics: Dithizone; Graphite; Hydrogen-Ion Concentration; Lead; Solid Phase Extraction; Spectrophotometry, Atomic; Vegetables; Water Pollutants, Chemical

2012
Dithizone functionalized CdSe/CdS quantum dots as turn-on fluorescent probe for ultrasensitive detection of lead ion.
    Journal of hazardous materials, 2013, Apr-15, Volume: 250-251

    Topics: Cadmium Compounds; Dithizone; Dose-Response Relationship, Drug; Fluorescence Resonance Energy Transfer; Fluorescent Dyes; Ions; Lead; Linear Models; Quantum Dots; Reproducibility of Results; Selenium Compounds; Solubility; Spectrometry, Fluorescence; Sulfides; Surface Properties

2013
Highly selective and sensitive optical sensor for determination of Pb2+ and Hg2+ ions based on the covalent immobilization of dithizone on agarose membrane.
    Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy, 2015, Feb-25, Volume: 137

    Topics: Cations, Divalent; Dithizone; Lead; Limit of Detection; Membranes, Artificial; Mercury; Sepharose; Spectrophotometry, Atomic

2015
Modification of an Iranian clinoptilolite nano-particles by hexadecyltrimethyl ammonium cationic surfactant and dithizone for removal of Pb(II) from aqueous solution.
    Journal of colloid and interface science, 2015, Feb-15, Volume: 440

    Topics: Ammonium Compounds; Dithizone; Iran; Lead; Microscopy, Electron, Scanning; Nanoparticles; Solutions; Spectroscopy, Fourier Transform Infrared; Surface-Active Agents; Thermogravimetry; Water; X-Ray Diffraction; Zeolites

2015
Screening of cadmium and lead in potentially contaminated waters using a spectrophotometric sequential injection lab-on-valve methodology.
    Talanta, 2015, Oct-01, Volume: 143

    Topics: Cadmium; Dithizone; Lead; Seawater; Spectrophotometry; Water Pollutants, Chemical

2015
Dithizone-modified graphene oxide nano-sheet as a sorbent for pre-concentration and determination of cadmium and lead ions in food.
    Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment, 2015, Volume: 32, Issue:11

    Topics: Adsorption; Cadmium; Dithizone; Food Analysis; Food Contamination; Graphite; Ions; Lead; Molecular Structure; Nanostructures; Oxides; Particle Size; Surface Properties

2015