Comparison of the endothelial coverage in everolimus and zotarolimus-eluting stents in normal, atherosclerotic, and bifurcation rabbit iliac arteries.
    Cardiovascular intervention and therapeutics, 2018, Volume: 33, Issue:1

    The aim of this study is to evaluate differences in stent endothelial coverage among the second generation of drug-eluting stents. Incomplete stent coverage is one of the major causes of late stent thrombosis. Rabbits fed a normal diet received an everolimus (Xience Prime; EES) and a zotarolimus-eluting stent (Resolute Integrity; R-ZES) in each iliac artery, followed by sacrifice at 14 and 28 days after stent implantation. In addition, a group of atherosclerotic rabbits similarly received EES and R-ZES, and were sacrificed at 28 days. The extent of stent endothelial coverage was assessed by scanning electron microscopy. To evaluate endothelial coverage after bifurcation stenting, rabbits received EES and R-ZES placed with culotte stenting at the iliac bifurcation, followed by sacrifice at 14 and 28 days. In rabbits fed a normal diet, the percent uncovered strut area 14 days after stent implantation was significantly higher in R-ZES than in EES (10.1% (IQR 9.8-15.5) vs. 3.0% (IQR 1.5-9.7), p = 0.03), whereas it was not significantly different at 28-days (3.9% (IQR 0.8-10.3) vs. 1.0% (IQR 0.0-2.8), p = 0.2). In rabbits with induced atheroma, R-ZES also showed less endothelial coverage 28 days after stent implantation (5.3% (IQR 2.2-9.9) vs. 1.1% (IQR 0-6.2), p = 0.03). In the culotte stenting model, the percent uncovered strut area of the proximal overlapped segment was significantly higher in R-ZES at 14 days (15.8% (IQR 14.3-17.7) vs. 8.8% (IQR 8.3-9.8), p = 0.03) and 28 days (9.9% (IQR 4.1-13.9) vs. 2.5% (IQR 1.6-6.7), p = 0.04) after stent implantation. The carina area also showed a better coverage in EES compared with R-ZES. EES showed a better stent endothelial coverage compared with R-ZES after stent implantation in the early phase in normals, in arteries with lipid rich plaque, and in bifurcation stented sites.

    Topics: Angiography; Animals; Blood Vessel Prosthesis Implantation; Drug-Eluting Stents; Endothelium, Vascular; Everolimus; Female; Iliac Artery; Immunosuppressive Agents; Microscopy, Electron, Scanning; Peripheral Arterial Disease; Rabbits; Sirolimus

2018
Crush Deformation of a Balloon-Expandable Stent Implanted in an Infrainguinal Bypass Graft.
    Vascular and endovascular surgery, 2017, Volume: 51, Issue:6

    A 59-year-old man with critical claudication underwent left femoro-anterior bypass grafting, which was uneventful. The graft was tunneled medially across the knee, then anterior to the tibia. His symptoms recurred 1 year later and he was found to have critical stenosis of the vein graft just proximal to the anterior tibial arterial anastomosis. This was treated with scaffolded balloon angioplasty and implantation of a coronary, zotarolimus-eluting balloon-expandable stent, which was also uneventful. However, his claudication again recurred 1 year later. Diagnostic angiography revealed crush, deformation and restenosis of the balloon-expandable stent requiring surgical revision of the bypass graft.

    Topics: Angioplasty, Balloon; Cardiovascular Agents; Computed Tomography Angiography; Critical Illness; Drug-Eluting Stents; Graft Occlusion, Vascular; Humans; Intermittent Claudication; Male; Middle Aged; Peripheral Arterial Disease; Prosthesis Design; Prosthesis Failure; Recurrence; Reoperation; Saphenous Vein; Sirolimus; Time Factors; Treatment Outcome; Ultrasonography, Doppler, Duplex; Vascular Grafting; Vascular Patency