zotarolimus has been researched along with Coronary-Restenosis* in 171 studies
15 review(s) available for zotarolimus and Coronary-Restenosis
Article | Year |
---|---|
Long-term effect of second-generation drug-eluting stents for coronary artery disease, everolimus-eluting versus zotarolimus-eluting stents: a meta-analysis.
Compared with the zotarolimus-eluting stent (ZES), the everolimus-eluting stent (EES) has reduced the risk of stent restenosis and thrombosis as found in a number of randomized-controlled trials (RCTs). However, the benefits have been variable.. We evaluate the long-term effect of EES and ZES on the risk of stent thrombosis and target lesion revascularization in patients receiving PCI. We identified RCTs by a systematic search of MEDLINE, EMBASE, and Cochrane Database.. Five RCTs (9853 patients) were included. Overall, EES significantly reduced the risk of target lesion revascularization [odds ratio (OR), 0.77; 95% confidence interval (CI), 0.62-0.95; P=0.01] compared with ZES therapy. However, there was no difference in the risk of target vessel revascularization (OR, 0.93; 95% CI, 0.78-1.10; P=0.38) and definite/probable stent thrombosis (OR, 0.83; 95% CI, 0.56-1.25; P=0.37) between the two groups. Furthermore, the risk of mortality (OR, 1.04; 95% CI, 0.84-1.27; P=0.73), myocardial infarction (OR, 0.95; 95% CI, 0.74-1.23; P=0.70), and major adverse cardiac event (OR, 0.96; 95% CI, 0.84-1.10; P=0.53) was similar between the two groups.. The new-generation Resolute-ZES and EES have a similar long-term safety and efficacy profile. Topics: Cardiovascular Agents; Chi-Square Distribution; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Humans; Myocardial Infarction; Odds Ratio; Percutaneous Coronary Intervention; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2015 |
Impact of technological developments in drug-eluting stents on patient-focused outcomes: a pooled direct and indirect comparison of randomised trials comparing first- and second-generation drug-eluting stents.
To establish whether technological improvements in drug-eluting stent (DES) technology introduced in second-generation (G2) DES have contributed to improving patient-focused outcomes.. We performed a systematic review of randomised clinical trials (RCT) comparing first-generation (G1) and G2 DES with a>9-month clinical follow-up. The primary endpoint for efficacy was ischaemia-driven target lesion revascularisation (ID-TLR); safety endpoints were all-cause death, myocardial infarction (MI) and stent thrombosis (ST). Sixteen RCTs involving 25,427 patients met eligibility criteria (17 comparisons). In these trials, paclitaxel (PES) and sirolimus (SES) were compared with everolimus (EES), zotarolimus (ZES) or biolimus A9 (BES) DES. G2 varied in metal alloy, strut thickness and type of drug-eluting matrix. Overall, G2 DES were associated with a 26% relative risk reduction (RRR) of MI (relative risk [RR]=0.74, 95% CI: 0.61-0.90, p=0.003) and ST (RR=0.70, 95% CI: 0.55-0.89, p=0.004), while no significant benefit was observed for ID-TLR and death. Use of 2G DES was associated with a significant reduction in the risk of ID-TLR (RR=0.66, 95% CI: 0.51-0.85, p=0.002), MI (RR=0.60, 95% CI: 0.49-0.72, p<0.001) and ST (RR=0.41, 95% CI: 0.26-0.65, p=0.001) when compared with PES. Strut thickness ≤91 µm in G2 DES was associated with a significantly lower risk of MI (RR=0.54, 95% CI: 0.51-0.86, p=0.002).. The introduction of thinner stent struts and other technological improvements made in G2 DES technology have translated into better patient outcomes. Overall, the net benefit of G2 DES over G1 DES is expressed in terms of ID-TLR and ST risk reduction but it could be masked by heterogeneities in the use of G1 comparators and the use of non-inferiority study designs in RCTs. Topics: Antineoplastic Agents; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Humans; Paclitaxel; Patient Outcome Assessment; Percutaneous Coronary Intervention; Prosthesis Design; Randomized Controlled Trials as Topic; Sirolimus | 2014 |
Efficacy and safety of zotarolimus-eluting stents compared with sirolimus-eluting stents in patients undergoing percutaneous coronary interventions--a meta-analysis of randomized controlled trials.
Whether ZES can further improve angiographic and clinical outcomes compared to SES still remains uncertain.. The aim of this study was to assess the efficacy and safety of zotarolimus-eluting stents (ZES) compared with sirolimus-eluting stents (SES) in patients undergoing percutaneous coronary interventions (PCI).. Major electronic information sources were explored for randomized controlled trials comparing ZES with SES among patients undergoing PCI during at least 9 months follow-up. The primary efficacy outcomes were target lesion revascularization (TLR), target vessel revascularization (TVR), and major adverse cardiac events (MACE); safety outcomes were stent thrombosis (ST), myocardial infarction (MI), and cardiac death.. Seven comparative studies were identified (a total of 5983 patients). When compared with ZES at 12-month follow-up, SES significantly reduced risk of MACE (relative risk [RR]: 0.74, 95% confidence interval [CI]: 0.61 to 0.89, p=0.002), and TLR (RR:0.39; 95% CI: 0.29 to 0.52; p<0.00001), without significant differences in terms of TVR (RR:0.68, 95% CI: 0.38 to 1.20; p=0.18), ST (RR:0.71; 95% CI: 0.39 to 1.31; p=0.28), cardiac death (RR:0.83; 95% CI: 0.49-1.42, p=0.50) or MI (RR:1.08; 95%CI: 0.80 to 1.45; p=0.62).. At 12-month follow-up, SES are superior to ZES in reducing the incidences of TLR and MACE in patients undergoing PCI, without significant differences in terms of TVR, ST, cardiac death, and MI. Topics: Coronary Restenosis; Drug-Eluting Stents; Humans; Percutaneous Coronary Intervention; Randomized Controlled Trials as Topic; Sirolimus; Treatment Outcome | 2013 |
Forget Mars and venus, men and women are from the same planet after all.
Topics: Aged; Aged, 80 and over; Angioplasty, Balloon, Coronary; Cohort Studies; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Paclitaxel; Prognosis; Prosthesis Failure; Retrospective Studies; Risk Assessment; Severity of Illness Index; Sex Factors; Sirolimus; Treatment Outcome | 2012 |
Impact of diabetes mellitus on vessel response in the drug-eluting stent era: pooled volumetric intravascular ultrasound analyses.
Exaggerated neointimal hyperplasia is considered as the primary mechanism for increased restenosis in patients with diabetes mellitus (DM) treated with bare-metal stent. However, the vessel response in DM and non-DM treated with different drug-eluting stents (DES) has not been systematically evaluated.. We investigated 3D intravascular ultrasound (postprocedure and 6 to 9 months) in 971 patients (267 with DM and 704 without DM) treated with sirolimus- (n=104), paclitaxel- (n=303), zotarolimus- (n=391), or everolimus- (n=173) eluting stents. Volumetric data were standardized by length as volume index (VI). At postprocedure, lumen VI at the stented segment was significantly smaller in DM than in non-DM, whereas vessel VI was similar between the 2 groups. At follow-up, neointimal obstruction and maximum cross-sectional narrowing (neointimal area/stent area) were not significantly different between the 2 groups with no interaction for the DES type. Consequently, lumen VI was smaller in DM than in non-DM at follow-up. In the reference segments, residual plaque burden at postprocedure was significantly greater in DM than in non-DM, although change in lumen VI was similar between the 2 groups. The arterial responses at the reference segments also showed no interaction for the DES type.. DM and non-DM lesions showed similar vessel response in both in-stent and reference segments regardless of the DES type. In the DES era, the follow-up lumen in DM patients seems to be determined primarily by the smaller lumen at postprocedure rather than exaggerated neointima within the stent or plaque proliferation at the reference segments. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chi-Square Distribution; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Diabetes Mellitus; Drug-Eluting Stents; Everolimus; Female; Humans; Hyperplasia; Linear Models; Male; Middle Aged; Multicenter Studies as Topic; Multivariate Analysis; Neointima; Paclitaxel; Predictive Value of Tests; Prosthesis Design; Randomized Controlled Trials as Topic; Retrospective Studies; Risk Factors; Sirolimus; Time Factors; Treatment Outcome; Ultrasonography, Interventional | 2012 |
Zotarolimus-eluting stent versus sirolimus-eluting and paclitaxel-eluting stents for percutaneous coronary intervention: a meta-analysis of randomized trials.
The zotarolimus-eluting stent (ZES) is a new drug-eluting stent that delivers zotarolimus, a synthetic analogue of sirolimus, through a biocompatible phosphorylcholine polymer coating. ZES has shown promising results compared with bare-metal stents, but its safety and efficacy against sirolimus-eluting (SES) and paclitaxel-eluting (PES) stents is yet to be established.. We aimed to summarize current evidence from randomized trials comparing ZES with SES and PES.. We searched the Medline, Embase and CENTRAL databases for randomized studies comparing ZES with SES and PES for percutaneous coronary intervention. Relevant clinical and angiographic outcomes were extracted and combined using random and fixed-effect models for heterogeneous and homogenous outcomes, respectively.. Seven randomized trials met the inclusion criteria: ZES group, n=3787; SES group, n=2606; PES group, n=1966. Compared with SES, ZES was associated with significantly higher odds of clinically driven target vessel revascularization (odds ratio [OR] 2.36, 95% confidence interval [CI] 1.78-3.14) and target lesion revascularization (OR 2.46, 95% CI 1.36-4.46). Compared with SES, ZES had higher in-stent restenosis (OR 6.13, 95% CI 3.96-9.50), late lumen loss 'in-stent' (mean difference [MD] 0.39 mm, 95% CI 0.34-0.44) and late lumen loss 'in-segment' (MD 0.18 mm, 95% CI 0.15-0.21). ZES was associated with higher in-stent late lumen loss than PES (MD 0.18 mm, 95% CI 0.07-0.28). There were no differences in mortality, reinfarction or stent thrombosis with ZES compared with SES and PES.. ZES is not superior to PES and is inferior to SES in terms of angiographic outcomes and clinically driven revascularization. Topics: Coated Materials, Biocompatible; Confidence Intervals; Coronary Angiography; Coronary Restenosis; Drug-Eluting Stents; Equipment Failure; Follow-Up Studies; Humans; Myocardial Infarction; Paclitaxel; Percutaneous Coronary Intervention; Phosphorylcholine; Randomized Controlled Trials as Topic; Sirolimus; Thrombosis; Treatment Outcome | 2012 |
Choice of drug-eluting stents.
Topics: Angioplasty, Balloon, Coronary; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Humans; Immunosuppressive Agents; Sirolimus; Stents | 2012 |
Paclitaxel-coated balloons - Survey of preclinical data.
Restenosis following interventions in the coronary or peripheral arteries develops over weeks to months. In coronary arteries the restenosis rate has been markedly reduced since the advent of drug-eluting stents. Non-stent-based methods for local drug delivery enable restenosis inhibition without the need for stent implantation, does not permanently change the structure of the vessel, are repeatable, and seems to be applicable where drug-eluting stents provide insufficient protection. Preclinical data indicate that short exposure of the vessel wall to a lipophilic inhibitor of cell proliferation is sufficient for preventing restenosis. Initial evidence to this effect emerged from an investigation of paclitaxel embedded in a matrix that enhances the solubility and release of the agent from the balloon coating as well as its transfer to the vessel wall. Further corroborating data from preclinical and clinical studies demonstrating a reduction in late lumen loss and lower restenosis rates led to the market introduction of a variety of paclitaxel-coated angioplasty balloons. The effectiveness of restenosis inhibition is not determined by the active agent alone. Other factors that are crucial for the effectiveness and safety of drug-coated angioplasty balloons are the formulation containing the agent and the coating technique. In this review we first outline the development of paclitaxel-coated balloons to then provide an overview of the preclinical results obtained with different paclitaxel-coated balloons and finally compare these with the outcome in patients. The article concludes with a short outlook on initial results with a zotarolimus-coated angioplasty balloon. Topics: Angioplasty, Balloon, Coronary; Coronary Restenosis; Drug Delivery Systems; Drug-Eluting Stents; Humans; Paclitaxel; Sirolimus | 2010 |
Future stent drug delivery systems.
Drug-eluting stents (DES) with antiproliferative drugs attached via polymers on the stent surface have reduced in-stent restenosis and repeat revascularization compared with bare metal stent (BMS) across nearly all lesion and patient subsets. However, the small number of patients with in-stent restenosis after DES treatment still exists. Furthermore, concerns about long-term safety of DES are raised, particularly regarding the higher-than-expected late-event thrombosis. There is no doubt that the DES will continue to play a pivotal role in the treatment of coronary artery disease, yet future designs need to incorporate features that reduce thrombosis and promote endothelialization along with maintaining the efficacy. This review focuses on novel generation of DES, discussing new programs, including new antiproliferative agents, novel polymeric and non polymeric stents. Topics: Absorbable Implants; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Equipment Design; Everolimus; Evidence-Based Medicine; Humans; Immunosuppressive Agents; Polymers; Prosthesis Design; Sirolimus; Tacrolimus | 2008 |
XIENCE V everolimus-eluting coronary stent system: a novel second generation drug-eluting stent.
Drug-eluting stents (DES) have been shown to be safe and significantly reduce clinical events and angiographic restenosis in the percutaneous treatment of coronary artery disease. Currently, three DES have been approved in Europe and Northern America: the sirolimus-eluting stent (SES), the paclitaxel-eluting stent (PES) and the zotarolimus-eluting stent (ZES). Everolimus, an analog of sirolimus, is an immunosuppressive and antiproliferative agent. In three studies, the SPIRIT I, FUTURE I and II, the everolimus-eluting stent has proven to be safe, well-tolerated and has shown very favorable clinical and angiographic results. Compared with earlier-generation DES, the XIENCE V everolimus-eluting coronary stent system (Advanced Cardiovascular Systems Inc., an Abbott Vascular Company, CA, USA) may provide enhanced deliverability, radiopacity with thinner strut filaments and, owing to a durable polymer, sustained drug elution and vascular compatibility. Topics: Angioplasty, Balloon, Coronary; Coronary Artery Disease; Coronary Restenosis; Drug Delivery Systems; Everolimus; Humans; Immunosuppressive Agents; Paclitaxel; Sirolimus; Stents; Technology Assessment, Biomedical | 2007 |
Clinical impact of in-stent late loss after drug-eluting coronary stent implantation.
Controversy exists about the clinical significance of in-stent late loss (ISLL) after drug-eluting stent (DES) implantation. We sought to clarify whether ISLL after DES implantation is related to a potential clinical impact.. We included in a meta-regression analysis 21 trials (8641 patients) that randomly compared DES with bare-metal stents (BMS). We evaluated the relationship between angiographic behaviour of DES and the clinical impact of using DES instead of BMS in each trial using meta-regression techniques, weighting by the number of patients included in each trial. Mean ISLL in patients allocated to DES and DeltaISLL (difference in ISLL in patients allocated to BMS and DES) were used as angiographic parameters of efficacy of DES. The number of patients needed to be treated (NNT) to prevent one target lesion revascularization (TLR) was used to quantify the clinical impact of using DES instead of BMS. There was a significant relationship between mean ISLL in patients allocated to DES and the clinical benefit of using DES instead of BMS, as measured with the NNT for TLR: NNT for TLR = 6.2 + 18.4 [ISLL-DES] (R = 0.62; P = 0.007). Therefore, a 0.1 mm increase in mean ISLL-DES was associated with a 1.8 increase in NNT for TLR. There was also a significant association between the degree of inhibition of neointimal hyperplasia of DES in comparison with BMS with the NNT for TLR: NNT for TLR = 17.1-11.8 [DeltaISLL] (R = 0.61; P = 0.008). Therefore, a 0.1 mm reduction in ISLL by using DES instead of BMS was associated with a 1.2 decrease in mean NNT for TLR.. There is a strong and significant association between the degree of inhibition of neointimal formation with the use of DES and the clinical impact of using DES instead of BMS. Topics: Coronary Restenosis; Delayed-Action Preparations; Humans; Immunosuppressive Agents; Paclitaxel; Randomized Controlled Trials as Topic; Sirolimus; Stents; Tacrolimus; Tubulin Modulators | 2007 |
Zotarolimus (ABT-578) eluting stents.
Drug-eluting stents have revolutionized the field of interventional cardiology and have provided a significant innovation for preventing coronary artery restenosis. Polymer coatings that deliver anti-proliferative drugs to the vessel wall are key components of these revolutionary medical devices. This article focuses on the development of stents which elute the potent anti-proliferative agent, zotarolimus, from a synthetic phosphorylcholine-based polymer known for its biocompatible profile. Zotarolimus is the first drug developed specifically for local delivery from stents for the prevention of restenosis and has been tested extensively to support this indication. Clinical experience with the PC polymer is also extensive, since more than 120,000 patients have been implanted to date with stents containing this non-thrombogenic coating. This review provides background on pre-clinical studies with zotarolimus, on the development of the biocompatible PC polymer and on the clinical trials conducted using two stent platforms which deliver this drug to patients with coronary artery disease. Topics: Coronary Restenosis; Drug Delivery Systems; Humans; Randomized Controlled Trials as Topic; Sirolimus; Stents | 2006 |
Overview of pharmacology and clinical trials program with the zotarolimus-eluting endeavor stent.
Despite considerable benefits associated with current drug-eluting stents (DES), continued attention to the safety, efficacy, and deliverability of first-generation DES has led to the development of new antiproliferative agents with alternative stent platforms and different drug carrier systems. Zotarolimus is a recently developed pharmacologic agent with both antiproliferative and anti-inflammatory properties. The Endeavor drug-eluting stent (Medtronic Vascular, Santa Rosa, CA) represents the combination of zotarolimus, a low-profile cobalt alloy stent platform, and a biocompatible phosphorylcholine drug carrier system. At present, four clinical trials examining the safety and efficacy of the Endeavor stent have been performed. Although these studies have enrolled patients with similar clinical and angiographic characteristics, they have differed in trial design and study population size and have been performed across a broad geographic and physician distribution. Despite these differences, the results of these trials demonstrate consistently low rates of angiographic restenosis and repeat revascularization in addition to a favorable safety profile, with no occurrences of late stent thrombosis through 1 year of follow-up. This review describes the pharmacology and design on the Endeavor stent, summarizes results from recent clinical trials evaluating the Endeavor stent, and provides an overview of ongoing and future directions for clinical investigation. Topics: Anti-Inflammatory Agents; Blood Vessel Prosthesis Implantation; Clinical Trials as Topic; Coated Materials, Biocompatible; Combined Modality Therapy; Coronary Restenosis; Coronary Stenosis; Humans; Phosphorylcholine; Prosthesis Design; Sirolimus; Stents | 2006 |
Technology Insight: an overview of research in drug-eluting stents.
Drug-eluting stents (DESs) have revolutionized interventional cardiology over the past few years to the extent that balloon angioplasty and bare stents did in the 1980s and 1990s. The first DESs became commercially available in Europe in 2002 and in the US in 2003, and it is estimated that up to 80% of patients who undergo stent implantation in the US now receive a DES. Two devices, Cypher sirolimus-eluting stents (Cordis Corporation, Miami Lakes, FL) and Taxus paclitaxel-eluting stents (Boston Scientific Corporation, Natick, MN), are currently licensed for sale in both regions. Multiple new devices using different drugs, carriers and stents are currently undergoing clinical trials to establish their efficacy and obtain approval for commercialization. While the remarkable reduction of restenosis has accounted for the success of DESs, concerns remain regarding long-term follow-up; published 3-year follow-up results are available for fewer than 200 patients overall. Reports of late stent thrombosis have emerged, particularly in relation to discontinuation of antiplatelet therapy. In patients treated with DESs, long-term administration of at least one antiplatelet agent must be continued following completion of the mandatory dual antiplatelet regimen. In this review, we summarize the findings available for DESs so far, discuss emerging safety and efficacy data, and look at the future directions for these devices. Topics: Antineoplastic Agents, Phytogenic; Clinical Trials as Topic; Coronary Restenosis; Endothelium, Vascular; Everolimus; Immunosuppressive Agents; Paclitaxel; Sirolimus; Stents | 2005 |
ABT-578-eluting stents. The promising successor of sirolimus- and paclitaxel-eluting stent concepts?
ABT-578 is a new synthetic analog of rapamycin, designed to inhibit smooth muscle cell proliferation-a key contributor to restenosis-by blocking the function of the mTOR cell cycle regulatory protein. Given these pharmacodynamics, ABT-578 was considered beneficial for intracoronary delivery to arrest the process responsible for neointimal hyperplasia after angioplasty and stenting. Consequently, the ABT-578-eluting ENDEAVOR stent system has been created, representing a potential new alternative for treating patients with coronary heart disease. In order to evaluate safety, feasibility and efficacy of this stent design, the ENDEAVOR clinical program has been started, including three randomized clinical trials. ENDEAVOR I is the first-in-man trial including 100 patients with native de novo coronary lesions. The 4-month follow-up data, recently presented, demonstrated safety and feasibility of this new drug-eluting stent (DES) concept with a 4-month MACE (major adverse cardiac events) rate of 2.0%. In order to evaluate this stent system in a larger patient population as well as more complex lesion subsets, the multicenter study ENDEAVOR II has been started including a total of 1,200 patients. The enrollment of this study was completed in January 2004. The aim of the US multicenter study ENDEAVOR III is a head-to-head comparison of the ENDEAVOR ABT-578-eluting stent system with the already approved sirolimus-eluting Cypher stent in 369 patients. If the results of both pivotal studies ENDEAVOR II and III confirm the efficacy of the ENDEAVOR stent design observed so far, the ENDEAVOR stent will be established as a new and promising contender in the field of DES. Topics: Administration, Topical; Angioplasty, Balloon, Coronary; Coated Materials, Biocompatible; Coronary Restenosis; Coronary Stenosis; Feasibility Studies; Humans; Immunosuppressive Agents; Paclitaxel; Randomized Controlled Trials as Topic; Sirolimus; Stents; Treatment Outcome | 2004 |
72 trial(s) available for zotarolimus and Coronary-Restenosis
Article | Year |
---|---|
Second-Generation Drug-Eluting Stents in Diabetes (SUGAR) trial: Rationale and study design.
Topics: Coated Materials, Biocompatible; Coronary Angiography; Coronary Restenosis; Diabetes Mellitus; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Prosthesis Design; Single-Blind Method; Sirolimus; Treatment Outcome | 2020 |
Outcomes of Patients With Coronary Arterial Bifurcation Narrowings Undergoing Provisional 1-Stent Treatment (from the BIONICS Trial).
Treatment of bifurcation lesions is technically challenging and has been associated with an increased risk of adverse events. We sought to evaluate the clinical and angiographic outcomes of patients who underwent bifurcation lesion provisional treatment in the BioNIR Ridaforolimus Eluting Coronary Stent System in Coronary Stenosis trial. A prospective, multicenter, 1:1 randomized trial was conducted to evaluate the safety and efficacy of ridaforolimus-eluting stents (RES) versus zotarolimus-eluting stents (ZES). Enrollment of bifurcation lesions treated with a provisional 1-stent technique was allowed. Bifurcation lesions were analyzed by an angiographic core laboratory. Outcomes were analyzed according to the presence of a bifurcation lesion treatment. Study population included 686 (35.8%) patients with and 1,228 (64.2%) patients without bifurcation lesion treatment. Procedural success was high and similar between groups. In 2 years, there was no difference in the rate of target lesion failure between the bifurcation and nonbifurcation groups (7.6% vs 7.3%, respectively, p = 0.81) regardless of the presence of side branch stenosis ≥50%. In 159 patients with angiographic follow-up, there was no difference in the rate of binary restenosis between groups (9.0% vs 9.2%, p = 0.96). Rates of target lesion failure at 1-year were similar with ZES and RES, and consistent in patients with and without bifurcation lesions (p Topics: Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Prospective Studies; Sirolimus | 2020 |
Outcomes in Patients Treated With Thin-Strut, Very Thin-Strut, or Ultrathin-Strut Drug-Eluting Stents in Small Coronary Vessels: A Prespecified Analysis of the Randomized BIO-RESORT Trial.
Stenting small-vessel lesions has an increased adverse cardiovascular event risk. Very thin-strut or ultrathin-strut drug-eluting stents might reduce this risk, but data are scarce.. To assess the outcome of all-comer patients with small coronary vessel lesions treated with 3 dissimilar types of drug-eluting stents.. This is a prespecified substudy of the Comparison of Biodegradable Polymer and Durable Polymer Drug-eluting Stents in an All Comers Population (BIO-RESORT) trial, an investigator-initiated, randomized, patient-blinded comparative clinical drug-eluting stent trial. Patients treated with ultrathin-strut sirolimus-eluting stents, very thin-strut everolimus-eluting stents, or previous-generation thin-strut zotarolimus-eluting stents were enrolled from December 2012 to August 2015. This multicenter trial was conducted in 4 Dutch centers for cardiac intervention. Of all 3514 all-comer BIO-RESORT participants, 1506 patients with treatment in at least 1 small-vessel lesion (reference vessel <2.5 mm) were included. Data were analyzed between September 2018 and February 2019.. Target lesion failure at 3-year follow-up, a composite of cardiac death, target vessel-related myocardial infarction, or target lesion revascularization, analyzed by Kaplan-Meier methods.. In 1452 of 1506 participants (96.4%) (1057 men [70.2%]; 449 women [29.8%]; mean [SD] age, 64.3 [10.4] years), follow-up was available. Target lesion failure occurred in 36 of 525 patients (7.0%) treated with sirolimus-eluting stents, 46 of 496 (9.5%) with everolimus-eluting stents, and 48 of 485 (10.0%) with zotarolimus-eluting stents (sirolimus-eluting vs zotarolimus-eluting hazard ratio [HR], 0.68; 95% CI, 0.44-1.05; P = .08; everolimus-eluting vs zotarolimus-eluting HR, 0.93; 95% CI, 0.62-1.39; P = .72). There was a difference in target lesion revascularizations between sirolimus-eluting and zotarolimus-eluting stents (2.1% vs 5.3%; HR, 0.40; 95% CI, 0.20-0.81; P = .009) that emerged after the first year of follow-up (1.0% vs 3.7%; P = .006); multivariate analysis showed that sirolimus-eluting stent implantation was independently associated with a lower target lesion revascularization rate at 3-year follow-up (adjusted HR, 0.42; 95% CI, 0.20-0.85; P = .02). In the everolimus-eluting stents, the revascularization rate was 4.0% (vs zotarolimus-eluting, HR, 0.74; 95% CI, 0.41-1.34; P = .31). There was no significant between-stent difference in cardiac death, target vessel myocardial infarction, or stent thrombosis.. Patients stented in small coronary vessels experienced fewer repeated revascularizations if treated with ultrathin-strut sirolimus-eluting stents vs previous generation thin strut zotarolimus-eluting stents. Further research is required to evaluate the potential effect of particularly thin stent struts.. ClinicalTrials.gov identifier: NCT01674803. Topics: Absorbable Implants; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prosthesis Design; Risk Factors; Sirolimus; Treatment Outcome | 2019 |
First-in-man randomised comparison of the BuMA Supreme biodegradable polymer sirolimus-eluting stent versus a durable polymer zotarolimus-eluting coronary stent: the PIONEER trial.
A second iteration of a sirolimus-eluting stent (SES) that has a biodegradable PLGA polymer coating with an electrografting base layer on a thin-strut (80 µm) cobalt-chromium platform (BuMA Supreme; SINOMED, Tianjin, China) has been developed. This first-in-man trial aimed to assess the efficacy and safety of the novel device.. This randomised, multicentre, single-blinded, non-inferiority trial compared the BuMA Supreme SES versus a contemporary durable polymer zotarolimus-eluting stent (ZES) in terms of angiographic in-stent late lumen loss (LLL) at nine-month follow-up as the primary endpoint. A total of 170 patients were randomly allocated to treatment with either SES (n=83) or ZES (n=87). At nine-month angiographic follow-up, in-stent LLL was 0.29±0.33 mm in the SES group and 0.14±0.37 mm in the ZES group (pnon-inferiority=0.45). The in-stent percent diameter stenosis and the binary restenosis rate of the two treatment arms were similar (19.2±12.0% vs. 16.1±12.6%, p=0.09, and 3.3% vs. 4.4%, p=1.00, respectively). At 12-month clinical follow-up, there was no difference between treatment arms with regard to the device-oriented composite clinical endpoint (4.9% vs. 5.7%; p=0.72).. The PIONEER trial did not meet its primary endpoint in terms of in-stent LLL at nine-month follow-up. However, this result did not translate into any increase in restenosis rate or impairment in 12-month clinical outcomes. Topics: Absorbable Implants; Aged; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Outcome Assessment, Health Care; Percutaneous Coronary Intervention; Prosthesis Design; Sirolimus | 2018 |
Safety and efficacy of the next generation Resolute Onyx zotarolimus-eluting stent: Primary outcome of the RESOLUTE ONYX core trial.
To assess the safety and efficacy of the novel Resolute (R-) Onyx drug-eluting stent (DES).. The R-Onyx DES consists of a composite wire with an outer shell of cobalt chromium alloy and a platinum-iridium inner core to enhance radiopacity, with thinner, swaged struts and modified stent geometry compared with the predicate Resolute DES, resulting in a slightly lower total drug load in most sizes.. This was a prospective, single-arm non-inferiority trial compared with a historical control. Patients with stable angina/ischemia and up to 2 de novo target lesions ≤35 mm long with reference vessel diameter (RVD) of 2.25-4.2 mm were enrolled. The primary endpoint was late lumen loss at 8-month follow-up. Propensity-score adjusted outcomes from the single-arm RESOLUTE-US trial served as the control.. Seventy-five patients (85 lesions) were enrolled. Mean patient age was 66 ± 9 years, 73% were male, and 32% had diabetes. Mean lesion length was 14.28 ± 6.68 mm, mean RVD was 2.57 ± 0.48 mm, and 86% of lesions were class B2/C. In-stent late lumen loss at 8 months was 0.24 ± 0.39 mm with R-Onyx DES compared with 0.36 ± 0.52 mm with Resolute DES (P < 0.001 for noninferiority, P = 0.029 for superiority). At 8 months, clinically driven target lesion revascularization occurred in 3 patients (4.0%) and target lesion failure occurred in 5 patients (6.7%).. In-stent late lumen loss is non-inferior, and appears to be superior, with the thin-strut novel composite wire R-Onyx DES compared with Resolute DES. Continued evolution of stent design can improve angiographic outcomes in complex lesions, even in the current era of next-generation DES. Topics: Aged; Angina, Stable; Cardiovascular Agents; Chromium Alloys; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Iridium; Male; Middle Aged; Percutaneous Coronary Intervention; Platinum; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome; Ultrasonography, Interventional; United States | 2018 |
Functional comparison between the BuMA Supreme biodegradable polymer sirolimus-eluting stent and a durable polymer zotarolimus-eluting coronary stent using quantitative flow ratio: PIONEER QFR substudy.
Quantitative flow ratio (QFR) based on three-dimensional quantitative coronary angiography (3D-QCA) is a novel method to assess physiological functionality after treatment with stents. The current study aimed to evaluate the difference in physiological functionality nine months after implantation of a bioresorbable polymer-based sirolimus-eluting stent with an electrografting base layer (BuMA Supreme: B-SES) versus a durable polymer-based zotarolimus-eluting stent (Resolute: R-ZES).. The current post hoc analysis was performed in the PIONEER randomised trial (1:1 randomisation to B-SES [83 patients/95 lesions] and R-ZES [87 patients/101 lesions]). QFR was measured in stented vessels in both arms at preprocedural, post-procedural and nine-month angiography without pharmacologically induced hyperaemia (contrast QFR). At nine months, both the values of QFR distal to the stent (B-SES: 0.89±0.10 vs. R-ZES: 0.89±0.11, p=0.97) and the number of vessels with QFR ≤0.8 were not significantly different between the two groups (11.0% vs. 12.8%, p=0.72), while the in-stent binary restenosis rate was also comparable (3.7% vs. 3.5%, p=1.00). QFR gradient across the device (∆QFR) at nine months was also similar between the groups (B-SES: 0.03±0.04 vs. R-ZES: 0.03±0.07, p=0.95).. Quantitative flow assessment nine months after stenting did not differ between B-SES and R-ZES, despite a significant difference in in-stent late lumen loss. Topics: Coronary Angiography; Coronary Restenosis; Drug-Eluting Stents; Humans; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Sirolimus; Stents; Treatment Outcome | 2018 |
5-Year Outcome Following Randomized Treatment of All-Comers With Zotarolimus-Eluting Resolute Integrity and Everolimus-Eluting PROMUS Element Coronary Stents: Final Report of the DUTCH PEERS (TWENTE II) Trial.
The study sought to evaluate for the first time the 5-year outcomes after treating an all-comers population with newer-generation cobalt chromium-based Resolute Integrity zotarolimus-eluting stents (ZES) (Medtronic, Santa Rosa, California) versus platinum chromium-based PROMUS Element everolimus eluting stents (EES) (Boston Scientific, Natick, Massachusetts).. The DUTCH PEERS (TWENTE II) (DUrable polymer-based sTent CHallenge of Promus ElemEnt versus ReSolute integrity: TWENTE II) trial is a randomized, multicenter, single-blinded, investigator-initiated all-comers trial that found at its main analysis similar 1-year safety and efficacy for both drug-eluting stents. It is the first randomized trial ever to investigate the Resolute Integrity ZES and the first trial to compare both devices.. In total, 1,811 patients were 1:1 randomized to ZES versus EES. We performed a pre-specified assessment of the 5-year clinical outcomes in terms of safety and efficacy. The main endpoint target vessel failure (TVF) is a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization. Secondary endpoints included the individual components of TVF, and stent thrombosis. The study was independently monitored, and adverse clinical events were independently adjudicated.. Five-year clinical follow-up data was available in 1,798 (99.3%) patients. The ZES and EES groups showed favorable outcomes, with similar 5-year incidence of TVF (13.2% vs. 14.2%; p. At 5-year follow-up, the Resolute Integrity ZES and PROMUS Element EES showed similar and sustained results in terms of safety and efficacy for treating a broad population of all-comers. Topics: Acute Coronary Syndrome; Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Middle Aged; Myocardial Infarction; Netherlands; Percutaneous Coronary Intervention; Prosthesis Design; Risk Factors; Single-Blind Method; Sirolimus; Time Factors; Treatment Outcome | 2018 |
A prospective randomised trial comparing the novel ridaforolimus-eluting BioNIR stent to the zotarolimus-eluting Resolute stent: six-month angiographic and one-year clinical results of the NIREUS trial.
The aim of this study was to evaluate the efficacy and safety of the BioNIR stent compared with the Resolute Integrity stent for the treatment of coronary artery disease.. This first-in-human, multicentre, single-blind randomised non-inferiority trial was performed in Europe and Israel. Patients with stable coronary artery disease or acute coronary syndromes were randomly assigned to treatment with BioNIR or Resolute Integrity stents in a 2:1 fashion. The primary endpoint was angiographic in-stent late lumen loss (LLL) at six months. Three hundred and two patients were randomised, of whom 261 (86.0%) underwent six-month angiographic follow-up. The BioNIR stent was non-inferior to the Resolute Integrity stent for the primary endpoint of in-stent LLL at six months (0.04±0.30 mm vs. 0.03±0.31 mm, respectively, pnoninferiority<0.0001). At 12-month follow-up, target lesion failure occurred in 3.4% in the BioNIR group and 5.9% in the Resolute Integrity group (p=0.22). Rates of MACE were similar between the BioNIR and Resolute Integrity groups (4.3% vs. 5.9%, respectively, p=0.45).. The BioNIR stent was non-inferior to the Resolute Integrity stent for the primary endpoint of angiographic in-stent LLL at six months. Clinical outcomes at one year were comparable between the two groups. Topics: Adult; Aged; Aged, 80 and over; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Sirolimus; Treatment Outcome | 2018 |
The OCT-ORION Study: A Randomized Optical Coherence Tomography Study Comparing Resolute Integrity to Biomatrix Drug-Eluting Stent on the Degree of Early Stent Healing and Late Lumen Loss.
Durable polymers used in drug-eluting stents are considered a potential cause of hypersensitivity inflammatory response adversely affecting stent healing. Using a sequential follow-up with optical coherence tomography, we compared the differences in healing profiles of 2 drug-eluting stents with a biodegradable or durable polymer.. Sixty patients with multivessel disease were prospectively enrolled to receive both study stents, which were randomly assigned to 2 individual vessels, a Resolute Integrity zotarolimus-eluting stent with a durable BioLinx polymer and a BioMatrix NeoFlex Biolimus A9-eluting stent with a biodegradable polylactic acid polymer. Optical coherence tomography was performed at baseline, then in 5 randomly assigned monthly groups at 2 to 6 months, and at 9 months in all patients. The primary end point was the difference in optical coherence tomography strut coverage at 9 months. Key secondary end points included angiographic late lumen loss and composite major adverse cardiac events (cardiac death, myocardial infarction, target lesion revascularization, and definite or probable stent thrombosis) at 9 months. Resolute Integrity zotarolimus-eluting stent showed significantly better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent at 2 to 6 months (. Despite having a durable polymer, Resolute Integrity zotarolimus-eluting stent exhibited better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent having a biodegradable polymer; both showed similar antiproliferative efficacy. This novel, longitudinal, sequential optical coherence tomography protocol using each patient as own control could achieve conclusive results in small sample size.. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01742507. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Hong Kong; Humans; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2018 |
Drug-Coated Balloon Versus Drug-Eluting Stent for Small-Vessel Disease: The RESTORE SVD China Randomized Trial.
The aim of this study was to evaluate the angiographic efficacy and clinical outcomes of the Restore paclitaxel-coated balloon in a randomized trial designed to enable its approval with an indication for small-vessel disease (SVD).. Higher rates of restenosis and stent thrombosis limit the effectiveness of drug-eluting stent (DES) treatment of SVD. Whether a drug-coated balloon (DCB)-only strategy is effective in de novo SVD is not yet established.. In the noninferiority RESTORE SVD China trial, eligible patients with reference vessel diameter ≥2.25 and ≤2.75 mm were randomized to the Restore DCB or the RESOLUTE Integrity DES in a 1:1 ratio stratified by diabetes and number of lesions treated. Patients with RVD ≥2.00 and <2.25 mm were enrolled in a nested very small vessel registry. Angiographic and clinical follow-up were planned at 9 months and 1 year, respectively, in all patients. The study was powered for the primary endpoint of 9-month in-segment percentage diameter stenosis.. Between August 2016 and June 2017, a total of 230 subjects at 12 sites were randomized to the DCB group (n = 116) or DES group (n = 114); 32 patients were treated with the DCB in the very small vessel cohort. Nine-month in-segment percentage diameter stenosis was 29.6 ± 2.0% with the DCB versus 24.1 ± 2.0% with the DES; the 1-sided 97.5% upper confidence limit of the difference was 10.9%, achieving noninferiority of the DCB compared with the DES (p for noninferiority < 0.001). The DCB and DES had comparable 1-year rates of target lesion failure (4.4% vs. 2.6%, p = 0.72).. In this multicenter randomized trial, the Restore DCB was noninferior to the RESOLUTE DES for 9-month in-segment percentage diameter stenosis. (Assess the Efficacy and Safety of RESTORE Paclitaxel Eluting Balloon Versus RESOLUTE Zotarolimus Eluting Stent for the Treatment of Small Coronary Vessel Disease; NCT02946307). Topics: Aged; Angioplasty, Balloon, Coronary; Cardiac Catheters; Cardiovascular Agents; China; Coated Materials, Biocompatible; Coronary Restenosis; Coronary Stenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Prosthesis Design; Registries; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2018 |
Outcomes Among Diabetic Patients Undergoing Percutaneous Coronary Intervention With Contemporary Drug-Eluting Stents: Analysis From the BIONICS Randomized Trial.
The authors sought to investigate the impact of diabetes mellitus (DM) on outcomes following contemporary drug-eluting stent (DES) implantation in the BIONICS (BioNIR Ridaforolimus Eluting Coronary Stent System in Coronary Stenosis) trial.. Patients with DM are at increased risk for adverse events following percutaneous coronary intervention (PCI).. A prospective, multicenter, 1:1 randomized trial was conducted to evaluate in a noninferiority design the safety and efficacy of ridaforolimus-eluting stents versus zotarolimus-eluting stents among 1,919 patients undergoing PCI. Randomization was stratified to the presence of medically treated DM, and a pre-specified analysis compared outcomes according to the presence or absence of DM up to 2 years.. The overall prevalence of DM was 29.1% (559 of 1,919). DM patients had higher body mass index, greater prevalence of hyperlipidemia and hypertension, and smaller reference vessel diameter. One-year target lesion failure (cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization) was significantly higher among diabetic patients (7.8% vs. 4.2%; p = 0.002), mainly due to higher target lesion revascularization (4.5% vs. 2.0%; p = 0.002). Rates of cardiac death, myocardial infarction, and stent thrombosis did not statistically vary. Among 158 patients undergoing 13-month angiographic follow-up, restenosis rates were 3 times higher in diabetic patients compared with nondiabetic patients (15.2% vs. 4.7%; p = 0.01). Clinical and angiographic outcomes were similar between ridaforolimus-eluting stent- and zotarolimus-eluting stent-treated patients.. Despite advances in interventional therapies, and the implementation of new-generation DES, diabetic patients still have worse angiographic and clinical outcomes compared with nondiabetic patients undergoing PCI. Topics: Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Restenosis; Coronary Stenosis; Coronary Thrombosis; Diabetes Mellitus; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prevalence; Prospective Studies; Prosthesis Design; Risk Factors; Single-Blind Method; Sirolimus; Time Factors; Treatment Outcome | 2018 |
First Report of the Resolute Onyx 2.0-mm Zotarolimus-Eluting Stent for the Treatment of Coronary Lesions With Very Small Reference Vessel Diameter.
The aim of this study was to explore the safety and efficacy of a dedicated drug-eluting stent for the treatment of coronary lesions with very small reference vessel diameter (RVD).. Smaller RVD is associated with increased risk for restenosis and target lesion failure (TLF) after stent implantation.. This was a prospective, single-arm, multicenter trial of the Resolute Onyx 2.0-mm zotarolimus-eluting stent. The primary endpoint was 12-month TLF, which was compared with a pre-specified performance goal. Subjects with stable or unstable angina or ischemia, target lesions ≤27 mm in length, and RVD ≥2.0 and <2.25 mm were eligible for enrollment. A subset of subjects underwent follow-up angiography at 13 months post-procedure.. A total of 101 subjects with 104 lesions were enrolled. The mean age was 67.3 ± 9.6 years, 47% of subjects had diabetes, the mean lesion length was 12.6 ± 6.3 mm, and the mean RVD was 1.91 ± 0.26 mm. The rate of TLF at 12 months was 5.0%, fulfilling the pre-specified performance goal of 19% (p < 0.001). The rates of target lesion revascularization and target vessel myocardial infarction were 2.0% and 3.0%, respectively. There were no episodes of stent thrombosis. In-stent late lumen loss was 0.26 ± 0.48 mm, and the rate of binary restenosis was 12.0%.. In this first report of a drug-eluting stent with a dedicated size to treat lesions with RVD <2.25 mm, the Resolute Onyx 2.0-mm zotarolimus-eluting stent was associated with a low rate of TLF and late lumen loss, without a signal for stent thrombosis. This novel-sized drug-eluting stent appears to be a feasible option for the treatment of coronary lesions in extremely small vessels. (Medtronic Resolute Onyx 2.0 mm Clinical Study; NCT02412501). Topics: Aged; Angina, Stable; Angina, Unstable; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Japan; Male; Middle Aged; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome; United States | 2017 |
The Effect of Cilostazol on the Angiographic Outcome of Drug-Eluting Coronary Stents Angiographic Analysis of the CILON-T (Influence of CILostazol-Based Triple Antiplatelet Therapy ON Ischemi Complication after Drug-Eluting StenT Implantation) Trial.
It is not clear if anti-restonotic effect of cilostazol is consistent for different types of drug-eluting stents (DES).The purpose of this study was to compare the anti-proliferative effect of cilostazol between DAT and TAT with consideration of confounding influences of DES type.Nine hundred and fifteen patients were randomized to either dual antiplatelet therapy (DAT; aspirin and clopidogrel) or triple antiplatelet therapy (TAT; aspirin, clopidogrel, and cilostazol) in the previous CILON-T trial. After excluding 70 patients who received both or neither stents, we analyzed 845 patients who received exclusively PES or ZES, and compared in-stent late loss at 6 months between both antiplatelet regimens (DAT versus TAT).Baseline angiographic and clinical characteristics were similar between the DAT (656 lesions in 425 patients) and the TAT group (600 lesions in 420 patients). The 6-month follow-up angiography was completed in 745 patients (88.2%). Quantitative coronary angiography showed that TAT significantly reduced in-stent late loss (DAT 0.62 ± 0.62 mm versus TAT 0.54 ± 0.49 mm, P = 0.015). Stent type, diabetes or lesion length did not interact with difference of late loss. However, reduction of late loss by cilostazol did not lead to a significant reduction in the rate of target lesion revascularization (TLR) (DAT 7.8% versus TAT 6.9%, P = 0.69) due to a nonlinear relationship found between late loss and TLR.The TAT group showed less in-stent late loss as compared to the DAT group. This was consistently observed regardless of DES type, lesion length, or diabetic status. However, reduction of late loss by cilostazol did not lead to a significant reduction in TLR. Topics: Aged; Antineoplastic Agents; Cilostazol; Coronary Angiography; Coronary Restenosis; Drug Therapy, Combination; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Paclitaxel; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Prospective Studies; Sirolimus; Tetrazoles | 2017 |
First-in-Human Evaluation of a Novel Polymer-Free Drug-Filled Stent: Angiographic, IVUS, OCT, and Clinical Outcomes From the RevElution Study.
This study sought to assess the safety and effectiveness of the drug-filled stent (DFS) (Medtronic, Santa Rosa, California) in the treatment of patients with coronary artery disease.. Polymer-free drug-eluting stents have the potential to improve clinical outcomes and facilitate shorter durations of dual antiplatelet therapy. The polymer-free DFS is made from a trilayered continuous wire with an outer cobalt chromium layer, a middle tantalum layer, and an inner lumen coated with sirolimus. Small laser-drilled holes on the abluminal stent surface control drug elution.. The RevElution trial enrolled 100 patients with de novo coronary lesions 2.25 to 3.50 mm in diameter and length ≤27 mm in 2 cohorts of 50 patients for angiographic, intravascular ultrasound, and clinical assessment at 9 or 24 months, with optical coherence tomography performed in a subset of 30 patients at each time period. The primary endpoint was angiographic in-stent late lumen loss at 9 months compared with Resolute zotarolimus-eluting stent (Medtronic) historical control data.. Fifty patients with 56 lesions were treated with DFS in the 9-month cohort. In-stent late lumen loss was 0.26 ± 0.28 mm for DFS and 0.36 ± 0.52 mm for Resolute (p. At 9 months, the polymer-free DFS was safe and effective with high rates of early strut coverage and noninferior late lumen loss compared to Resolute. (Medtronic RevElution Trial [RevElution]; NCT02480348). Topics: Australia; Chromium Alloys; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Coronary Vessels; Drug Therapy, Combination; Drug-Eluting Stents; Female; Humans; Latin America; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Predictive Value of Tests; Prosthesis Design; Risk Factors; Singapore; Sirolimus; Tantalum; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2017 |
Angiographic outcomes of Orsiro biodegradable polymer sirolimus-eluting stents and Resolute Integrity durable polymer zotarolimus-eluting stents: results of the ORIENT trial.
We performed a randomised controlled open-label non-inferiority trial to compare angiographic outcomes between the ultra-thin strut, biodegradable hybrid polymer Orsiro sirolimus-eluting stent (O-SES) and the durable biocompatible polymer Resolute Integrity zotarolimus-eluting stent (R-ZES).. A total of 372 patients planned to undergo percutaneous coronary revascularisation were randomly assigned 2:1 to treatment with O-SES or R-ZES (250 and 122 patients, respectively). O-SES was non-inferior to R-ZES for the primary endpoint, in-stent late lumen loss at nine months (median 0.06 mm [interquartile range, -0.09 to 0.24 mm] versus 0.12 mm [-0.07 to 0.32 mm]; p for non-inferiority <0.001; p for superiority=0.205). Percent diameter stenosis was significantly lower in the O-SES group than in the R-ZES group (15.0 [10.0 to 20.0] versus 20.0 [13.3 to 26.0]; p=0.002). Target lesion failure occurred in 2.4% and 3.3% of the O-SES and R-ZES groups, respectively (p=0.621). Subgroup analyses showed consistently similar outcomes between the two groups in terms of the primary endpoint, except for the diabetic subgroup.. O-SES was non-inferior to R-ZES in terms of in-stent late loss at nine months. Angiographic restenosis and clinical adverse events were low in both groups. This study confirms the good safety and efficacy profiles of both contemporary coronary stents. Topics: Adult; Aged; Aged, 80 and over; Coronary Angiography; Coronary Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Polymers; Sirolimus; Treatment Outcome | 2017 |
Randomized Angiographic and Intravascular Ultrasound Comparison of Dual-Antiplatelet Therapy vs Triple-Antiplatelet Therapy to Reduce Neointimal Tissue Proliferation in Diabetic Patients.
Previous studies have suggested a benefit of cilostazol in addition to standard dual-antiplatelet therapy (DAPT), reducing in-stent late luminal loss and restenosis after percutaneous coronary intervention (PCI) with bare-metal and drug-eluting stent (DES) implantation. However, there is a paucity of intravascular ultrasound (IVUS) assessment of neointimal tissue hyperplasia (NIH) after triple-antiplatelet therapy (TAPT), especially in diabetic patients treated with DES.. This prospective, placebo-controlled trial was conducted in diabetic patients randomized (1:1) to receive either standard DAPT (aspirin and clopidogrel) vs TAPT with cilostazol for a minimum of 12 months after PCI with Endeavor zotarolimus-eluting stent (E-ZES). The primary endpoint was the 9-month comparison of percentage of NIH in both groups. Additionally, we compared in-stent late lumen loss, binary restenosis, major adverse cardiac event (MACE; cardiac death, non-fatal myocardial infarction, and restenosis) rates, and the incidence of vascular/bleeding complications.. In total, 133 diabetic patients were enrolled (cilostazol cohort = 65 patients) with 56.4% male and mean age of 60.8 years. Overall, the two cohorts were comparable in terms of baseline clinical and angiographic characteristics, except for the reference vessel diameter, which was smaller among patients randomized to cilostazol (2.48 ± 0.46 mm vs 2.69 ± 0.48 mm; P=.01). At 9 months, there was a non-significant trend toward less percentage of NIH obstruction in the TAPT cohort (33.2 ± 8.29% vs 35.1 ± 8.45%; P=.07). However, this finding did not impact angiographic late-lumen loss (0.60 ± 0.46 mm cilostazol group vs 0.64 ± 0.48 mm control group; P=.30) and binary restenosis (9.8% vs 6.8%; P=.99). MACE rate also did not significantly differ between the cohorts (13.8% cilostazol group vs 8.8% control group; P=.81). Of note, the addition of a third antiplatelet agent did not increase vascular and bleeding complications.. In diabetic patients treated with E-ZES, TAPT with cilostazol did not add any significant benefit in terms of NIH suppression or MACE reduction. Topics: Aspirin; Cilostazol; Clopidogrel; Comorbidity; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Diabetes Mellitus; Drug Therapy, Combination; Drug-Eluting Stents; Female; Hemorrhage; Humans; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Sirolimus; Tetrazoles; Ticlopidine; Treatment Outcome | 2017 |
Neointimal coverage of zotarolimus-eluting stent at 1, 2, and 3 months' follow-up: an optical coherence tomography study.
Incomplete neointimal coverage and malapposed struts after stenting are associated with increased risk of stent thrombosis. We aimed to evaluate neointimal coverage early after Resolute zotarolimus-eluting stent (R-ZES) implantation using optical coherence tomography (OCT). A total of 20 patients with de novo native coronary lesions with R-ZES were enrolled. Among these patients, 20 stented lesions in 19 patients were evaluated at 1, 2, and 3 months after R-ZES implantation. The strut apposition and neointimal coverage were evaluated by OCT. Neointimal hyperplasia (NIH) thickness and percentage of covered struts and the proportion of incompletely apposed struts were measured at 1-mm intervals. The mean percentages of covered stent struts were over 85 % within 3 months (88.4 ± 6.3 % at 1 month, 95.5 ± 5.5 % at 2 months, 93.6 ± 3.5 % at 3 months). The percentages of incompletely apposed struts were not significantly different among the groups (4.4 ± 4.2 % at 1 month, 1.9 ± 1.9 % at 2 months, 3.1 ± 2.2 % at 3 months, p = 0.51). Mean NIH thickness (38.9 ± 8.1 μm at 1 month, 70.6 ± 18.8 μm at 2 months, 54.1 ± 5.9 at 3 months, p = 0.0016) was thickest in the 2 months group. Most of all OCT findings within 2 months demonstrated neointimal coverage with low signal intensity. The neointimal coverage of ZES-R was over 85 % within 3 months. These data may support shorter requirement of dual antiplatelet therapy duration with R-ZES. Topics: Aged; Aged, 80 and over; Cardiovascular Agents; Coronary Restenosis; Coronary Stenosis; Coronary Thrombosis; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Japan; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Predictive Value of Tests; Prospective Studies; Risk Factors; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2016 |
Incidence and predictors of unplanned non-target lesion revascularisation up to three years after drug-eluting stent implantation: insights from a pooled analysis of the RESOLUTE Global Clinical Trial Program.
To compare the incidence and predictors of target lesion revascularisation (TLR) and non-TLR after percutaneous coronary intervention with drug-eluting stents (DES).. We pooled patient-level data on 6,137 patients (Resolute zotarolimus-eluting stent: 5,016, XIENCE everolimus-eluting stent: 1,121) in the RESOLUTE Global Program. At three years, clinically driven TLR, unplanned non-TLR, and no revascularisation occurred in 186, 618, and 5,333 patients, respectively. On multivariate analysis, predictors of both TLR and non-TLR were pre-procedure diameter stenosis (%) (odds ratio [OR] 1.01, 95% confidence interval [CI] [1.01-1.02], and OR 0.99 [0.99-1.00]), diabetes (OR 1.46 [1.07-1.99], and OR 1.37 [1.15-1.64]), and prior PCI (OR 1.42 [1.01-2.00], and OR 1.41 [1.18-1.68]). Baseline characteristics associated with TLR only were prior coronary artery bypass graft surgery (OR 2.85 [1.91-4.27]), in-stent restenosis (OR 2.35 [1.43-3.83]), age (OR 0.98 per year [0.97-1.00]), hypertension (OR 1.64 [1.10-2.44]), and pre-procedure reference vessel diameter (OR 0.74 per mm [0.55-0.99]). Baseline characteristics associated with non-TLR only were lesion location (left anterior descending vs. all others) (OR 0.70 [0.59-0.83]), and hyperlipidaemia (OR 1.42 [1.15-1.75]).. The cumulative incidence of non-TLR at three years in patients treated with current-generation DES was almost three times higher than TLR. Topics: Adult; Aged; Aged, 80 and over; Cardiovascular Agents; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Incidence; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2016 |
Five-year clinical outcomes in patients with diabetes mellitus treated with polymer-free sirolimus- and probucol-eluting stents versus second-generation zotarolimus-eluting stents: a subgroup analysis of a randomized controlled trial.
Improved outcomes in patients with diabetes mellitus undergoing percutaneous coronary intervention remain an unmet clinical need. We assessed the long-term efficacy and safety of novel polymer-free sirolimus- and probucol-eluting stent in diabetic patients enrolled in intracoronary stenting and angiographic results: test efficacy of sirolimus- and probucol-eluting versus zotarolimus-eluting stents 5 trial.. In a pre-specified subgroup analysis, outcomes of diabetic patients treated with a sirolimus- and probucol-eluting stent or a second-generation zotarolimus-eluting stent were compared. The primary endpoint was a device-oriented composite outcome comprising cardiac death, target vessel-related myocardial infarction (MI), or target lesion revascularization (TLR) at 5-year follow-up. Event-free survival was assessed using the Kaplan-Meier method. Hazard ratios (HR) and 95 % confidence intervals (CI) were estimated from univariate Cox proportional hazards models.. A total of 870 patients with diabetes mellitus were treated with either a sirolimus- and probucol-eluting stent (n = 575) or a second-generation zotarolimus-eluting stent (n = 295). At 5 years, the rate of device-oriented composite endpoint was comparable between the sirolimus- and probucol-eluting stent and the second-generation zotarolimus-eluting stent (32.9 versus 33.4 %, HR 0.88, 95 % CI 0.76-1.26). No significant differences were observed between the sirolimus- and probucol-eluting stent and the second-generation zotarolimus-eluting stent groups in the incidence of cardiac death (15.6 versus 16.7 % HR 0.92, 95 % CI 0.63-1.32), target-vessel MI (4.6 versus 6.6 %, HR 0.73, 95 % CI 0.40-1.34), and TLR (18.6 versus 18.8 %, HR 1.00, 95 % CI, 0.72-1.41). The rate of definite or probable stent thrombosis was low and similar in both groups (2.5 versus 2.6 %, HR 1.02, 95 % CI, 0.41-2.52).. In patients with diabetes the long-term efficacy and safety of a polymer-free sirolimus- and probucol-eluting stent were comparable to a second-generation durable polymer zotarolimus-eluting stent. Trial registration ClinicalTrials.gov NCT00598533. Registered 10 January 2008. Topics: Aged; Cardiovascular Agents; Cardiovascular Diseases; Coronary Angiography; Coronary Restenosis; Coronary Thrombosis; Diabetic Angiopathies; Disease-Free Survival; Drug-Eluting Stents; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Probucol; Proportional Hazards Models; Prosthesis Design; Retreatment; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2016 |
Randomised study of a bioabsorbable polymer-coated sirolimus-eluting stent: results of the DESSOLVE II trial.
To compare the efficacy and safety of the MiStent absorbable polymer sirolimus-eluting stent (APSES) with a zotarolimus-eluting stent (ZES).. The trial was a 2:1 randomisation at 26 sites of 184 patients implanted with an APSES (n=123) versus a ZES (n=61). Following stent implantation, all patients underwent quantitative coronary angiography at baseline and at nine months of follow-up, while a select subgroup also underwent optical coherence tomography (OCT). The primary efficacy hypothesis was superiority of in-stent late lumen loss (LLL) of APSES compared to ZES. At nine months, the primary endpoint was met, with a mean in-stent LLL of 0.27±0.46 mm in 103 APSES patients versus 0.58±0.41 mm in 52 ZES patients (p<0.001). The proportion of uncovered stent struts by OCT at nine months was very low in both groups. The mean neointimal thickness of covered struts (p=0.002) and percent net volume obstruction (p≤0.003) were significantly lower in the APSES than in the ZES group. Major adverse cardiac event and stent thrombosis rates were low and comparable between groups.. The DESSOLVE II trial demonstrated superiority in the primary efficacy endpoint of nine-month mean LLL for APSES compared to ZES. Strut coverage by OCT was high with both stents and the clinical safety endpoints including stent thrombosis were equally low in both groups. ClinicalTrials.gov Identifier: NCT01294748. Topics: Absorbable Implants; Aged; Antibiotics, Antineoplastic; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Polymers; Single-Blind Method; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2015 |
Three-year clinical outcome in the Primary Stenting of Totally Occluded Native Coronary Arteries III (PRISON III) trial: a randomised comparison between sirolimus-eluting stent implantation and zotarolimus-eluting stent implantation for the treatment of t
Sirolimus-eluting stents (SES) have been shown to be superior to Endeavor zotarolimus-eluting stents (ZES) and comparable to Resolute ZES at eight-month angiography in patients treated for total coronary occlusions (TCO). This study investigated clinical outcome at three-year follow-up.. The PRISON III trial investigated the efficacy and safety of SES against ZES (Endeavor and Resolute) in two study phases. In the first phase, 51 patients were randomised to receive SES and 46 to Endeavor ZES. In the second phase, 103 and 104 patients were randomised to SES or Resolute ZES, respectively. Between one and three years there were only a few additional clinical events in all groups. As a result, the rates of target lesion revascularisation 12.2% vs. 19.6%, p=0.49, target vessel failure 14.3% vs. 19.6%, p=0.68, and definite or probable stent thrombosis 4.1% vs. 2.2% were comparable between SES and Endeavor ZES at three years. In the second study phase, the rates of target lesion revascularisation 10% vs. 5.9%, p=0.42, target vessel failure 10% vs. 7.9%, p=0.79 and definite or probable stent thrombosis 1.0% vs. 0% were similar between SES and Resolute ZES.. The present study demonstrated a low incidence of clinical events between one- and three-year follow-up with either SES compared to Endeavor ZES or SES versus Resolute ZES in patients treated for total coronary occlusions. Topics: Aged; Antibiotics, Antineoplastic; Cardiovascular Diseases; Coronary Occlusion; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Longitudinal Studies; Male; Middle Aged; Myocardial Infarction; Myocardial Revascularization; Percutaneous Coronary Intervention; Reoperation; Sirolimus; Thrombosis | 2015 |
Neointimal response to second-generation drug-eluting stents in diabetic patients with de-novo coronary lesions: intravascular ultrasound study.
The aim of this study was to evaluate the extent of neointimal response after the implantation of a second-generation drug-eluting stent, zotarolimus-eluting stent (ZES-ER, Endeavor Resolute) or everolimus-eluting stent (EES, Xience V), using intravascular ultrasound (IVUS) in diabetic patients.. In all, 154 diabetic patients with de-novo coronary lesions were randomized to be implanted with a ZES-ER or EES, and the angiographic follow-up at 9 months combined with a complete IVUS study was available for 96 patients with 101 lesions.. Baseline demographic and lesion parameters were similar in both groups at index percutaneous coronary intervention. On follow-up angiography, in-stent late lumen loss and minimal lumen diameter were not different between the two groups. On IVUS study, neointimal hyperplasia volume [median (interquartile range): ZES-ER vs. EES; 2.25 mm (0.57-6.25) vs. 1.59 mm (0.45-8.37), P=0.615] and in-stent percentage of volume obstruction [median (interquartile range): ZES-ER vs. EES; 1.16% (0.33-3.61) vs. 0.77% (0.29-4.01), P=0.615] showed similar results between the two groups.. In diabetic patients, the second-generation drug-eluting stents, ZES-ER and EES, were comparable in inhibiting neointimal proliferation. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Vessels; Diabetic Angiopathies; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Pilot Projects; Predictive Value of Tests; Prosthesis Design; Republic of Korea; Risk Factors; Sirolimus; Time Factors; Treatment Outcome; Ultrasonography, Interventional | 2015 |
Long-term outcome of sirolimus-eluting and zotarolimus-eluting coronary stent implantation in patients with and without diabetes mellitus (a Danish organization for randomized trials on clinical outcome III substudy).
We compared 5-year clinical outcomes in diabetic and nondiabetic patients treated with Endeavor zotarolimus-eluting stents (ZESs; Endeavor Sprint, Medtronic, Santa Rosa, California) or Cypher sirolimus-eluting stents (SESs; Cordis, Johnson & Johnson, Warren, New Jersey) coronary implantation. We randomized 2,332 patients to either ZESs (n = 1,162, n = 169 diabetic patients) or SESs (n = 1,170, n = 168 diabetic patients) stratified according to presence or absence of diabetes mellitus. End points included major adverse cardiac event (MACE), a composite of cardiac death, myocardial infarction, target vessel revascularization (TVR), and definite stent thrombosis. Among diabetic patients, MACE occurred more frequently in patients treated with ZESs than SESs (48 [28.4%] vs 31 [18.5%]; odds ratio [OR] 1.75, 95% confidence interval [CI] 1.05 to 2.93, p = 0.032) because of a higher rate of TVR (32 [18.9%] vs 14 [8.3%]; OR 2.57, 95% CI 1.32 to 5.02, p = 0.006). Among nondiabetic patients, ZES and SES had similar MACE rates at 5-year follow-up but SES was associated with a significantly higher risk of definite stent thrombosis (10 [1.0%] vs 23 [2.3%]; OR 0.43, 95% CI 0.20 to 0.91, p = 0.028). Moreover, during the last 4 years, ZES had fewer MACE, TVR, and stent thrombosis events among nondiabetic patients. In conclusion, SES remains superior to ZES in patients with diabetes throughout the 5-year follow-up, however, among nondiabetic patients, SES demonstrated a highly dynamic performance with favorable initial results followed by a late catch-up that included an overall higher risk of stent thrombosis. Topics: Blood Vessel Prosthesis Implantation; Case-Control Studies; Coronary Artery Disease; Coronary Restenosis; Diabetes Complications; Diabetes Mellitus; Drug-Eluting Stents; Female; Graft Occlusion, Vascular; Humans; Male; Myocardial Infarction; Prosthesis Failure; Reoperation; Sirolimus; Thrombosis; Treatment Outcome | 2015 |
Five-year results of a randomised comparison of titanium-nitride-oxide-coated stents with zotarolimus-eluting stents for coronary revascularisation.
Stents with a passive coating of titanium-nitride-oxide (TiNO) have been compared with Endeavor® zotarolimus-eluting stents (E-ZES) with regard to the primary endpoint of in-stent late lumen loss at six to eight months. The objective of the present analysis was to compare the long-term outcomes of TiNO stents with E-ZES up to five years of clinical follow-up.. A total of 302 patients had been randomly allocated to treatment with TiNO or E-ZES. Up to five years of follow-up, major adverse cardiac events (MACE), the composite of cardiac death, myocardial infarction, or clinically indicated target vessel revascularisation (TLR), were observed in 27.6% of patients treated with TiNO stents and 25.3% of patients treated with E-ZES (RR 1.13, 95% CI: 0.72-1.75, p=0.60), with the majority of events related to clinically indicated TVR (TiNO 21.7% versus E-ZES 20.7%, RR 1.10, 95% CI: 0.67-1.81). There were no differences with respect to individual events including cardiac death, myocardial infarction or stent thrombosis between the two treatment arms up to five years of follow-up. A majority of patients remained free from angina throughout the entire study duration (TiNO 77.3% versus E-ZES 76.1%, p=0.92).. Final five-year outcomes of the TIDE trial comparing TiNO stents with E-ZES revealed increased rates of MACE driven primarily by clinically indicated TVR. The TIDE trial is registered at ClinicalTrials.gov: NCT00492908. Topics: Aged; Antibiotics, Antineoplastic; Cardiovascular Diseases; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Myocardial Revascularization; Percutaneous Coronary Intervention; Proportional Hazards Models; Reoperation; Sirolimus; Titanium; Treatment Outcome | 2015 |
Zotarolimus-eluting versus bare-metal stents in uncertain drug-eluting stent candidates.
The use of drug-eluting stents (DES) in patients at high risk of bleeding or thrombosis has not been prospectively studied; limited data are available in patients who have a low restenosis risk.. This study sought to compare a hydrophilic polymer-based, second-generation zotarolimus-eluting stent (ZES) with a unique drug fast-release profile versus bare-metal stents (BMS) under similar durations of dual-antiplatelet therapy (DAPT).. We randomly assigned 1,606 patients with stable or unstable symptoms, and who on the basis of thrombotic bleeding or restenosis risk criteria, qualified as uncertain candidates for DES, to receive ZES or BMS. DAPT duration was on the basis of patient characteristics, rather than stent characteristics, and allowed for a personalized 1-month dual antiplatelet regimen. The primary endpoint was the risk of 1-year major adverse cardiovascular events (MACE), which included death, myocardial infarction (MI), or target vessel revascularization (TVR).. Median DAPT duration was 32 days (interquartile range [IQR]: 30 to 180 days) and did not differ between the groups. In the ZES group, 140 patients (17.5%) reached the primary endpoint, compared with 178 patients (22.1%) in the BMS group (hazard ratio: 0.76; 95% confidence interval: 0.61 to 0.95; p = 0.011) as a result of lower MI (2.9% vs. 8.1%; p < 0.001) and TVR rates (5.9% vs.10.7%; p = 0.001) in the ZES group. Definite or probable stent thrombosis was also significantly reduced in ZES recipients (2.0% vs. 4.1%; p = 0.019).. Compared with BMS, DES implantation using a stent with a biocompatible polymer and fast drug-eluting characteristics, combined with an abbreviated, tailored DAPT regimen, resulted in a lower risk of 1-year MACE in uncertain candidates for DES implantation. (Zotarolimus-eluting Endeavor Sprint Stent in Uncertain DES Candidates [ZEUS] Study; NCT01385319). Topics: Aged; Aged, 80 and over; Aspirin; Biocompatible Materials; Clopidogrel; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Hemorrhage; Humans; Immunosuppressive Agents; Male; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Postoperative Complications; Risk Assessment; Risk Factors; Sirolimus; Ticlopidine; Treatment Outcome | 2015 |
Comparison of Short- and Long-Term Cardiac Mortality in Early Versus Late Stent Thrombosis (from Pooled PROTECT Trials).
Studies have indicated varying mortality risks with timing of stent thrombosis (ST), but few have been adequately powered with prospective late follow-up. PROTECT randomized 8,709 subjects to either Endeavor zotarolimus-eluting or Cypher sirolimus-eluting stents. PROTECT Continued Access enrolled 1,018 patients treated with Endeavor zotarolimus-eluting stents. Subjects completed at least 4 and 3 years of follow-up, respectively. ARC-defined definite and probable ST events were stratified by time from index procedure: early (≤30 days), late (>30 and ≤360 days), and very late (>360 days). Rates of death and myocardial infarction were analyzed by ST timing. Median follow-up was 4.1 years. There were 184 ST events (1.9%): 61 early, 27 late, and 96 very late. Patient and procedural characteristics were similar between timing groups. There was no difference in dual-antiplatelet therapy use at discharge (97%) or 1 year (84%). Cardiac death in patients with ST at 4 years occurred in 32.1% compared with 2.5% in patients without ST (p <0.001). Combined rates of cardiac death and myocardial infarction did not differ according to ST timing, yet early ST was more commonly associated with cardiac death at 4 years than later ST (50.8% for early vs 18.5% for late vs 24.0% for very late; p <0.001). The relation between ST timing and outcomes did not differ between stent types. In conclusion, in prospective data, cardiac death was more common after early ST than later ST. Although ST remains infrequent, continued efforts to determine how to reduce ST, particularly within the first 30 days, are warranted. (The PROTECT trial is registered with ClinicalTrials.gov, number NCT00476957.). Topics: Aged; Cause of Death; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Follow-Up Studies; Graft Occlusion, Vascular; Humans; Immunosuppressive Agents; Male; Middle Aged; Platelet Aggregation Inhibitors; Prospective Studies; Risk Factors; Sirolimus | 2015 |
Two-year outcomes after first- or second-generation drug-eluting or bare-metal stent implantation in all-comer patients undergoing percutaneous coronary intervention: a pre-specified analysis from the PRODIGY study (PROlonging Dual Antiplatelet Treatment
This study sought to assess device-specific outcomes after implantation of bare-metal stents (BMS), zotarolimus-eluting Endeavor Sprint stents (ZES-S), paclitaxel-eluting stents (PES), or everolimus-eluting stents (EES) (Medtronic Cardiovascular, Santa Rosa, California) in all-comer patients undergoing percutaneous coronary intervention.. Few studies have directly compared second-generation drug-eluting stents with each other or with BMS.. We randomized 2,013 patients to BMS, ZES-S, PES, or EES implantation. At 30 days, each stent group received up to 6 or 24 months of clopidogrel therapy. The key efficacy endpoint was the 2-year major adverse cardiac event (MACE) including any death, myocardial infarction, or target vessel revascularization, whereas the cumulative rate of definite or probable stent thrombosis (ST) was the key safety endpoint.. Clinical follow-up at 2 years was complete for 99.7% of patients. The MACE rate was lowest in EES (19.2%; 95% confidence interval [CI]: 16.0 to 22.8), highest in BMS (32.1%; 95% CI: 28.1 to 36.3), and intermediate in PES (26.2%; 95% CI: 22.5 to 30.2) and ZES-S (27.8%; 95% CI: 24.1 to 31.9) groups (chi-square test = 18.9, p = 0.00029). The 2-year incidence of ST in the EES group (1%; 95% CI: 0.4 to 2.2) was similar to that in the ZES-S group (1.4%; 95% CI: 0.7 to 2.8), whereas it was lower compared with the PES (4.6%, 95% CI: 3.1 to 6.8) and BMS (3.6%; 95% CI: 2.4 to 5.6) groups (chi-square = 16.9; p = 0.0001).. Our study shows that cumulative MACE rate, encompassing both safety and efficacy endpoints, was lowest for EES, highest for BMS, and intermediate for PES and ZES-S groups. EES outperformed BMS also with respect to the safety endpoints with regard to definite or probable and definite, probable, or possible ST. (PROlonging Dual antiplatelet treatment after Grading stent-induced Intimal hyperplasia studY [PRODIGY]; NCT00611286). Topics: Aged, 80 and over; Chi-Square Distribution; Clopidogrel; Coronary Restenosis; Coronary Thrombosis; Drug Administration Schedule; Drug Therapy, Combination; Drug-Eluting Stents; Everolimus; Female; Humans; Hyperplasia; Italy; Kaplan-Meier Estimate; Male; Metals; Middle Aged; Myocardial Infarction; Neointima; Paclitaxel; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Prosthesis Design; Risk Factors; Sirolimus; Stents; Ticlopidine; Time Factors; Treatment Outcome | 2014 |
Modifying effect of dual antiplatelet therapy on incidence of stent thrombosis according to implanted drug-eluting stent type.
To investigate the putative modifying effect of dual antiplatelet therapy (DAPT) use on the incidence of stent thrombosis at 3 years in patients randomized to Endeavor zotarolimus-eluting stent (E-ZES) or Cypher sirolimus-eluting stent (C-SES).. Of 8709 patients in PROTECT, 4357 were randomized to E-ZES and 4352 to C-SES. Aspirin was to be given indefinitely, and clopidogrel/ticlopidine for ≥ 3 months or up to 12 months after implantation. Main outcome measures were definite or probable stent thrombosis at 3 years. Multivariable Cox regression analysis was applied, with stent type, DAPT, and their interaction as the main outcome determinants. Dual antiplatelet therapy adherence remained the same in the E-ZES and C-SES groups (79.6% at 1 year, 32.8% at 2 years, and 21.6% at 3 years). We observed a statistically significant (P = 0.0052) heterogeneity in treatment effect of stent type in relation to DAPT. In the absence of DAPT, stent thrombosis was lower with E-ZES vs. C-SES (adjusted hazard ratio 0.38, 95% confidence interval 0.19, 0.75; P = 0.0056). In the presence of DAPT, no difference was found (1.18; 0.79, 1.77; P = 0.43).. A strong interaction was observed between drug-eluting stent type and DAPT use, most likely prompted by the vascular healing response induced by the implanted DES system. These results suggest that the incidence of stent thrombosis in DES trials should not be evaluated independently of DAPT use, and the optimal duration of DAPT will likely depend upon stent type (Clinicaltrials.gov number NCT00476957). Topics: Aspirin; Blood Vessel Prosthesis; Clopidogrel; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Fibrinolytic Agents; Graft Occlusion, Vascular; Humans; Male; Middle Aged; Platelet Aggregation Inhibitors; Prospective Studies; Prosthesis Failure; Sirolimus; Ticlopidine; Treatment Outcome | 2014 |
Differential clinical outcomes after 1 year versus 5 years in a randomised comparison of zotarolimus-eluting and sirolimus-eluting coronary stents (the SORT OUT III study): a multicentre, open-label, randomised superiority trial.
In head-to-head comparisons of coronary drug-eluting stents, the primary endpoint is traditionally assessed after 9-12 months. However, the optimum timepoint for this assessment remains unclear. In this study, we assessed clinical outcomes at up to 5 years' follow-up in patients who received two different types of drug-eluting stents.. We undertook this multicentre, open-label, randomised superiority trial at five percutaneous coronary intervention centres in Denmark. We randomly allocated 2332 eligible adult patients (≥18 years of age) with an indication for drug-eluting stent implantation to the zotarolimus-eluting Endeavor Sprint stent (Medtronic, Santa Rosa, CA, USA) or the sirolimus-eluting Cypher Select Plus stent (Cordis, Johnson & Johnson, Warren, NJ, USA). Randomisation of participants was achieved by computer-generated block randomisation and a telephone allocation service. The primary endpoint of the SORT OUT III study was a composite of major adverse cardiac events-cardiac death, myocardial infarction, and target vessel revascularisation-at 9 months' follow-up. In this study, endpoints included the occurrence of major adverse cardiac events and definite stent thrombosis at follow-up times of up to 5 years. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT00660478.. We randomly allocated 1162 patients to receive the zotarolimus-eluting stent and 1170 to the sirolimus-eluting stent. At 5-year follow-up, rates of major adverse cardiac events were similar in patients treated with both types of stents (zotarolimus-eluting stents 197/1162 [17.0%] vs sirolimus-eluting stents 182/1170 [15.6%]; odds ratio [OR] 1.10, 95% CI 0.88-1.37; p=0.40). This finding was indicative of the directly contrasting results for rates of major adverse cardiac events at 1-year follow up (zotarolimus 93/1162 [8.0%] vs sirolimus 46/1170 [3.9%]; OR 2.13, 95% CI 1.48-3.07; p<0.0001) compared with those at follow-up between 1 and 5 years (104 [9.0%] vs 136 [11.6%]; OR 0.78, 95% CI 0.59-1.02; p=0.071). At 1-year follow-up, definite stent thrombosis was more frequent after implantation of the zotarolimus-eluting stent (13/1162 [1.1%]) than the sirolimus-eluting stent (4/1170 [0.3%]; OR 3.34, 95% CI 1.08-10.3; p=0.036), whereas the opposite finding was recorded for between 1 and 5 years' follow-up (zotarolimus-eluting stent 1/1162 [0.1%] vs sirolimus-eluting stent 21/1170 [1.8%], OR 0.05, 95% CI 0.01-0.36; p=0.003). 26 of 88 (30%) target lesion revascularisations in the zotarolimus-eluting stent group occurred between 1 and 5 years' follow-up, whereas 54 of 70 (77%) of those in the sirolimus-eluting stent group occurred during this follow-up period.. The superiority of sirolimus-eluting stents compared with zotarolimus-eluting stents at 1-year follow-up was lost after 5 years. The traditional 1-year primary endpoint assessment therefore might be insufficient to predict 5-year clinical outcomes in patients treated with coronary drug-eluting stent implantation.. Cordis and Medtronic. Topics: Aged; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Cytostatic Agents; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Research Design; Single-Blind Method; Sirolimus; Time Factors; Treatment Outcome | 2014 |
Drug-eluting stent implantation in patients with acute coronary syndrome - the Activity of Platelets after Inhibition and Cardiovascular Events: Optical Coherence Tomography (APICE OCT) study.
To our knowledge, no randomised study has compared rates of uncovered stent struts in everolimus (EES) vs. new-generation zotarolimus-eluting (ZES-R) stents in acute coronary syndrome (ACS). The aim of our study was to evaluate the completeness of neointimal coverage with optical coherence tomography (OCT) in ACS patients treated with drug-eluting stents (DES) comparing EES versus new-generation ZES-R.. All eligible ACS patients admitted to four Italian centres with a clinical indication for culprit lesion intervention were randomised 1:1 to EES or ZES-R. The primary study endpoint was the percentage of uncovered stent struts evaluated by optical coherence tomography (OCT) at six months. Secondary endpoints were the percentage of malapposed stent struts, percent neointimal hyperplasia cross-sectional area (CSA) and major adverse cardiac events (MACE) at six months. A total of 60 patients were randomised to EES (n=29) or ZES-R (n=31). No differences were observed in baseline characteristics between the two groups. Overall, 31.7% presented with STEMI, of which 68.4% were anterior. The other patients comprised 41.7% NSTEMI and 26.7% troponin-negative ACS. A mean of 1.3±0.6 lesions were treated per patient, with a mean of 1.3±0.5 stents per lesion. At 30 days there was one sudden death. Six-month OCT analysis was performed in 25 lesions in the EES group and in 24 lesions in the ZES-R group. There was no difference in the primary endpoint of uncovered stent struts between groups (EES 6.42% [3.27, 9.57] vs. ZES-R 7.07% [3.22, 10.92]; p=0.80). Furthermore, there were no differences between groups in the percentage of malapposed stent struts, either with (EES 1.19% [0.34, 2.04] vs. ZES-R 0.85% [0.40, 1.30]; p=0.49) or without coverage (EES 1.06% [0.12, 2.01] vs. ZES-R 0.24% [0.05, 0.44]; p=0.09). Percent neointima CSA was similar in both groups (EES 37.0% [18.6, 55.3] vs. ZES-R 26.6% [18.4, 34.8]; p=0.31). At six-month clinical follow-up, no additional patients died or suffered MI. There were four MACE in the EES group and one in the ZES-R group.. In our study, in patients presenting with ACS, both EES and ZES-R had low percentages of malapposed and uncovered stent struts at six-month OCT analysis. Topics: Acute Coronary Syndrome; Aged; Coronary Restenosis; Coronary Stenosis; Coronary Vessels; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Single-Blind Method; Sirolimus; Tomography, Optical Coherence | 2014 |
Endeavour zotarolimus-eluting stent reduces stent thrombosis and improves clinical outcomes compared with cypher sirolimus-eluting stent: 4-year results of the PROTECT randomized trial.
To compare the long-term clinical safety between two drug-eluting stents with different healing characteristics in the Patient Related Outcomes with Endeavour (E-ZES) vs. Cypher (C-SES) Stenting Trial (PROTECT). At 3 years, there was no difference in the primary outcome of definite or probable stent thrombosis or in the other main secondary clinical outcomes consisting of the composite of death or myocardial infarction (MI). Prespecified 4-year clinical follow-up was analysed.. Patient Related OuTcomes with Endeavour vs. Cypher Stenting Trial was a prospective, open-label randomized-controlled superiority trial powered to look at differences in long-term clinical safety, including stent thrombosis. Dual antiplatelet therapy (DAPT) was prescribed for ≥ 3 months and up to 12 months based on current guidelines. Patient Related OuTcomes with Endeavour vs. Cypher Stenting Trial enrolled 8791 patients undergoing elective or emergency PCI to E-ZES or C-SES. There was no difference in DAPT usage between the two groups up to 4 years. At 4-year follow-up, the primary outcome occurred in 1.6% of E-ZES vs. 2.6% of C-SES patients [HR 0.63 (95% CI 0.46-0.85), P = 0.003]. The composite of all-cause death or large MI occurred in 6.7% of E-ZES vs. 8.0% of C-SES-treated patients [HR 0.84 (95% CI 0.71-0.98), P = 0.024].. Drug-eluting coronary stents with different healing characteristics demonstrated different late safety profiles: after 4 years, compared with C-SES, E-ZES reduced the risk of stent thrombosis and the risk of the composite endpoints of death or MI. Appropriately powered large-scale trials with long-term follow-up are critical to determine clinical safety and efficacy of permanently implanted coronary stents. This trial is registered with ClinicalTrials.gov, number NCT00476957. Topics: Coronary Restenosis; Coronary Thrombosis; Drug Therapy, Combination; Drug-Eluting Stents; Female; Graft Occlusion, Vascular; Humans; Immunosuppressive Agents; Male; Middle Aged; Myocardial Infarction; Platelet Aggregation Inhibitors; Prosthesis Failure; Sirolimus; Treatment Outcome | 2014 |
Zotarolimus- and paclitaxel-eluting stents in an all-comer population in China: the RESOLUTE China randomized controlled trial.
This study sought to compare clinical outcomes and angiographic findings using the Resolute zotarolimus-eluting stent (R-ZES) (Medtronic, Santa Rosa, California) versus the Taxus Liberte paclitaxel-eluting stent (PES) (Boston Scientific, Natick, Massachusetts) in an all-comer Chinese population.. Concerns regarding restenosis risk led to new-generation drug-eluting stents (DES) designed for use in patients with complex clinical or lesion characteristics. In-stent late lumen loss (LLL) is a measure of restenosis risk.. Patients with an indication for treatment with a DES were randomized in a 1:1 ratio to placement of at least 1 R-ZES or PES with minimal exclusions. The primary endpoint was angiographic in-stent LLL at 9 months post-procedure. Clinical endpoints at 12 months are compared between the 2 stents.. A total of 198 patients received a R-ZES, and 202 patients received a PES. Most patients were male; 25.8% and 29.2% of R-ZES and PES patients, respectively, had diabetes. Over 70% of lesions in both cohorts were American College of Cardiology/American Heart Association lesion classification Type B2 and C (B2/C). In-stent LLL was 0.16 ± 0.38 mm for R-ZES and 0.33 ± 0.52 mm for PES at 9 months (p < 0.001; 95% confidence interval [CI]: -0.26 to -0.08). The rates of clinically driven target lesion revascularization were 1.5% for R-ZES and 7.0% for PES (p = 0.011). The rate of target lesion failure was 5.6% for R-ZES and 11% for PES (p = 0.068).. In an all-comers Chinese population, 9-month in-stent LLL was significantly less with R-ZES compared with PES, which was reflected in lower revascularization rates at 12 months for the R-ZES patients. Results are consistent with previous clinical trials of the R-ZES in all-comer populations. (Resolute Zotarolimus-Eluting Stent Versus the Taxus Liberte Paclitaxel-Eluting Stent for Percutaneous Coronary Intervention in China [R-China RCT]; NCT01334268). Topics: Aged; Cardiovascular Agents; China; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Paclitaxel; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome | 2013 |
A randomized, controlled, multicenter trial to evaluate the safety and efficacy of Zotarolimus- vs. Paclitaxel-eluting stents in de novo occlusive lesions in coronary arteries: five-year results from the ZOMAXX I trial.
The ZOMAXX I trial tested the noninferiority of a zotarolimus-eluting coronary stent (ZoMaxx(™) ) when compared with a paclitaxel-eluting coronary stent (Taxus(™) Express(2™) ) in a randomized trial of percutaneous intervention for de novo coronary artery stenosis. Angiographic analysis at the primary endpoint of 9 months has been reported previously. The purpose of this follow-on analysis was to describe the clinical results of the ZoMaxx and Taxus cohorts of the ZOMAXX I trial after 5 years.. In the ZOMAXX I trial, 199 patients received a ZoMaxx stent and 197 patients received a Taxus stent at 29 investigative sites in Europe, Australia, and New Zealand. The two groups were generally well matched with respect to both clinical and lesional characteristics, including the incidence of diabetes (ZoMaxx 22% vs. Taxus 26%; P = 0.29), reference vessel diameter (ZoMaxx 2.79 ± 0.43 mm vs. Taxus 2.81 ± 0.46 mm; P = 0.65), and lesion length (ZoMaxx 14.9 ± 5.7 mm vs. Taxus 14.6 ± 5.5; P = 0.61). Through 5 years of follow-up, a total of 21 patients had died, six patients had withdrawn, nine had been lost to follow-up, and 13 missed their 5-year visit, leaving a total of 347 patients for analysis (169 ZoMaxx and 178 Taxus). At the 5-year time point, there were no significant differences in any clinical metric including ischemia-driven target lesion revascularization (TLR; ZoMaxx 10.6% vs. Taxus 7.1%; P = 0.29), Q-wave myocardial infarction (ZoMaxx 1.5% vs. Taxus 1.0%; P = 0.99), definite/probable stent thrombosis (ZoMaxx 1.5% vs. Taxus 3.0%; P = 0.34), and cardiac death (ZoMaxx 3.0% vs. Taxus 1.0%; P = 0.28).. After 5 years, the differences in clinical outcome between patients treated with ZoMaxx vs. Taxus stents did not reach statistical significance. However, the nominally higher rate of ischemia-driven TLR (10.6 vs. 7.1%) and the previously reported higher rate of restenosis after 9 months suggest that the ZoMaxx stent afforded less neointimal inhibition when compared with Taxus. © 2013 Wiley Periodicals, Inc. Topics: Aged; Australia; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Coronary Thrombosis; Drug-Eluting Stents; Europe; Female; Humans; Male; Middle Aged; Myocardial Infarction; Neointima; New Zealand; Paclitaxel; Percutaneous Coronary Intervention; Prosthesis Design; Risk Factors; Severity of Illness Index; Sirolimus; Time Factors; Treatment Outcome | 2013 |
Final 5-year outcomes from the Endeavor zotarolimus-eluting stent clinical trial program: comparison of safety and efficacy with first-generation drug-eluting and bare-metal stents.
The aim of this study was to evaluate late safety and efficacy outcomes among patients enrolled in clinical trials comparing Endeavor zotarolimus-eluting stents (E-ZES) (Medtronic, Inc., Santa Rosa, California) with first-generation drug-eluting stents (DES) and bare-metal stents (BMS).. Despite demonstration of higher angiographic luminal loss and restenosis with E-ZES compared with alternative DES, whether differences in these early angiographic measures translate into more disparate late clinical events is uncertain.. Among 3,616 patients undergoing percutaneous coronary revascularization in 5 registration trials, late safety and efficacy events were compared between E-ZES (n = 2,132) versus sirolimus- or paclitaxel-eluting stents (n = 888) or BMS (n = 596).. Compared with a parallel cohort of patients treated with first-generation DES and BMS, 5-year rates of cardiac death/myocardial infarction (MI) (5.8% vs. 8.8% DES, p = 0.003; vs. 8.4% BMS, p = 0.02) and major adverse cardiac events (16.1% vs. 20.6% DES, p = 0.009; vs. 24.6% BMS, p < 0.001) were significantly lower with E-ZES. The E-ZES was associated with significantly lower target lesion revascularization (TLR) compared with BMS (7.4% vs. 16.3%, p < 0.001) but similar to comparator DES (7.4% vs. 8.1%, p = 0.63). Despite higher TLR in the first year with E-ZES compared with DES, between 1- and 5-year follow-up, rates of cardiac death/MI, TLR, and definite/probable stent thrombosis were significantly lower with E-ZES.. Over 5 years, significant differences in cardiac death/MI and composite endpoints favored treatment with E-ZES over comparator BMS and DES. Rates of clinical restenosis and safety events, including stent thrombosis beyond the first year of revascularization, remain stable with E-ZES, leading to significant differences compared with first-generation DES. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Kaplan-Meier Estimate; Male; Metals; Middle Aged; Myocardial Infarction; Paclitaxel; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Stents; Time Factors; Treatment Outcome | 2013 |
Usefulness of intravascular ultrasound to predict outcomes in short-length lesions treated with drug-eluting stents.
Intravascular ultrasound (IVUS) offers tomographic images of the coronary artery, helping physicians to refine drug-eluting stent (DES) implantation in angiographically complex lesions. However, controversy exists regarding whether the routine use of IVUS in short-length lesions leads to improved clinical outcomes after DES implantation. Therefore, we evaluated the usefulness of IVUS in predicting major adverse cardiac events (MACE), including cardiovascular death, myocardial infarction, or target vessel revascularization, at 1 year after DES implantation in short-length lesions. The present study was a subanalysis of the REal Safety and Efficacy of a 3-month dual antiplatelet Therapy following Endeavor zotarolimus-eluting stent implantation (RESET) study with different clinical outcome parameters. The study population consisted of 662 patients with IVUS guidance and 912 patients with angiography guidance who underwent DES implantation (stent length ≤24 mm). In the IVUS-guided group, adjuvant postdilation was more frequently performed (43.0% vs 34.6%, p <0.001), and the postintervention minimal lumen diameters were greater (2.88 ± 0.44 mm vs 2.72 ± 0.43 mm, p <0.001). MACE occurred in 15 IVUS-guided (2.3%) and 19 angiographically guided (2.1%) patients (p = 0.872). In a subset of patients with diabetes mellitus (n = 292), the MACE rate was 3.4% (n = 4) and 1.7% (n = 3) in the IVUS- and angiographically guided patients, respectively (p = 0.384). The MACE rate in the IVUS- and angiographically guided patients with acute coronary syndrome (n = 601) was 1.1% (n = 3) and 2.7% (n = 9), respectively (p = 0.194). The clinical benefits of IVUS-guided DES implantation compared with angiographically guided DES implantation in short-length lesions could not be confirmed even in patients with clinically high-risk presentations (acute coronary syndrome and diabetes mellitus). In conclusion, routine IVUS guidance does not provide clinical benefits when performing short-length DES implantation. Topics: Aged; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prognosis; Sirolimus; Treatment Outcome; Ultrasonography, Interventional | 2013 |
Long-term efficacy and safety of Zotarolimus-eluting stent in patients with diabetes mellitus: pooled 5-year results from the ENDEAVOR III and IV trials.
To assess long-term outcomes of Endeavor Zotarolimus-eluting stent (E-ZES) implantation in patients with diabetes mellitus (DM).. Patients with DM and coronary artery disease have lower restenosis with drug-eluting stent (DES) compared with bare-metal stents. Recent data suggest that the E-ZES is inferior to other DES in this population.. Patient-level data for 601 patients with DM from the ENDEAVOR III and ENDEAVOR IV trials were pooled, of which 337 were treated with E-ZES and 264 were treated with other DES. The primary outcome was target vessel failure (TVF) in the course of 5 years. Outcomes are reported as rates using Kaplan-Meier (KM) survival method and differences between E-ZES and other stent types (sirolimus-eluting stent or paclitaxel-eluting stent) were compared using the log-rank statistic. The independent effect of stent type on TVF was assessed using Cox proportional hazards regression.. Baseline characteristics were similar between the groups. Five-year TVF KM rate estimate was numerically lower for E-ZES, but the difference did not reach statistical significance (20.2 vs. 26.9%, P = 0.065). The 5-year KM rate estimates of major adverse cardiac events (17.7 vs. 26.6%, P = 0.012), death (7.6 vs. 15.0%, P = 0.004), and myocardial infarction (1.3 vs. 5.1%, P = 0.011) were also lower for E-ZES versus other DES.. Patients with DM implanted with E-ZES have favorable long-term outcomes compared to first-generation DES. Long-term performance of DES should be assessed routinely and may differ from initial performance. Topics: Adult; Aged; Aged, 80 and over; Cardiovascular Agents; Coronary Artery Disease; Coronary Restenosis; Diabetic Angiopathies; Drug-Eluting Stents; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Paclitaxel; Percutaneous Coronary Intervention; Proportional Hazards Models; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2013 |
Tissue coverage and neointimal hyperplasia in overlap versus nonoverlap segments of drug-eluting stents 9 to 13 months after implantation: in vivo assessment with optical coherence tomography.
Histologic experimental studies have reported incomplete neointimal healing in overlapping with respect to nonoverlapping segments in drug-eluting stents (DESs), but these observations have not been confirmed in human coronary arteries hitherto. On the contrary, angiographic and optical coherence tomography studies suggest that DES overlap elicits rather an exaggerated than an incomplete neointimal reaction.. Optical coherence tomography studies from 2 randomized trials including sirolimus-eluting, biolimus-eluting, everolimus-eluting, and zotarolimus-eluting stents were analyzed at 9- to 13-month follow-up. Coverage in overlapping segments was compared versus the corresponding nonoverlapping segments of the same stents, using statistical pooled analysis.. Forty-two overlaps were found in 31 patients: 11 in sirolimus-eluting stents, 3 in biolimus-eluting stents, 17 in everolimus-eluting stents, and 11 in zotarolimus-eluting stents. The risk ratio of incomplete coverage was 2.35 (95% CI 1.86-2.98) in overlapping versus nonoverlapping segments. Thickness of coverage in overlaps was only 85% (95% CI 81%-90%) of the thickness in nonoverlaps. Significant heterogeneity of the effect was observed, especially pronounced in the comparison of thickness of coverage (I(2) = 90.31).. The effect of overlapping DES on neointimal inhibition is markedly heterogeneous: on average, DES overlap is associated with more incomplete and thinner coverage, but in some cases, the overlap elicits an exaggerated neointimal reaction, thicker than in the corresponding nonoverlapping segments. These results might help to understand why overlapping DES is associated with worse clinical outcomes, both in terms of thrombotic phenomena and in terms of restenosis and revascularization. Topics: Coronary Restenosis; Coronary Stenosis; Coronary Vessels; Drug-Eluting Stents; Everolimus; Feasibility Studies; Female; Follow-Up Studies; Humans; Hyperplasia; Immunosuppressive Agents; Male; Middle Aged; Neointima; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2013 |
Zotarolimus- versus everolimus-eluting stents for unprotected left main coronary artery disease.
This study sought to compare the safety and efficacy of the zotarolimus-eluting stent (ZES) and the everolimus-eluting stent (EES) for treatment of unprotected left main coronary artery (uLMCA) disease.. The second-generation ZES and EES have reduced the risk of restenosis in large patient cohorts. However, their comparative performance in uLMCA lesions is not known.. In this study, patients with symptomatic coronary artery disease undergoing percutaneous coronary intervention for uLMCA lesions were randomly assigned to receive either a ZES (n = 324) or an EES (n = 326). The primary endpoint was the combined incidence of death, myocardial infarction, and target lesion revascularization at 1 year. Secondary endpoints were definite or probable stent thrombosis at 1 year and angiographic restenosis based on analysis of the left main coronary artery area at follow-up angiography.. At 1 year, the cumulative incidence of the primary endpoint was 17.5% in the ZES group and 14.3% in the EES group (relative risk: 1.26; 95% confidence interval [CI]: 0.85 to 1.85; p = 0.25). Three patients in the ZES group (0.9%) and 2 patients in the EES group (0.6%) experienced definite or probable stent thrombosis (p > 0.99). All-cause mortality at 1 year was equal in the 2 groups (5.6%; relative risk: 1.00; 95% CI: 0.52 to 1.93; p = 0.98). Angiographic restenosis occurred in 21.5% of patients in the ZES group and 16.8% in the EES group (relative risk: 1.28; 95% CI: 0.86 to 1.92; p = 0.24).. Within the statistical limitations of the present study, treatment of uLMCA lesions with a ZES or an EES provided comparable clinical and angiographic outcomes at 1-year follow-up. Topics: Aged; Aged, 80 and over; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Humans; Immunosuppressive Agents; Middle Aged; Myocardial Infarction; Sirolimus | 2013 |
Angiographic and clinical comparison of novel Orsiro Hybrid sirolimus-eluting stents and Resolute Integrity zotarolimus-eluting stents in all-comers with coronary artery disease (ORIENT trial): study protocol for a randomized controlled trial.
The Orsiro Hybrid sirolimus-eluting stent is a newly developed third-generation drug-eluting stent, featuring a unique dual-polymer mix. An active bioabsorbable polymer delivers the anti-proliferative drug, sirolimus, via controlled release, while a passive biocompatible polymeric coating shields the metallic strut from surrounding tissue, preventing interaction. To date, the Orsiro Hybrid sirolimus-eluting stent has excelled in terms of late lumen loss at 9 months in a first-in-man single-arm trial. However, the efficacy and safety data for Orsiro Hybrid sirolimus-eluting stents in a broader population of all-comers are limited. The present study offers an angiographic and clinical comparison of the Orsiro Hybrid sirolimus-eluting stent and the Resolute Integrity zotarolimus-eluting stent in the treatment of patients with coronary artery disease.. The ORIENT trial is a multicenter, randomized, open-label, parallel-arm study designed to demonstrate the non-inferiority of the Orsiro Hybrid sirolimus-eluting stent relative to the Resolute Integrity zotarolimus-eluting stent. A total of 375 patients with a spectrum of coronary artery disease will undergo prospective, random assignment to a Orsiro Hybrid sirolimus-eluting stent or Resolute Integrity zotarolimus-eluting stent (2:1 ratio), for a primary endpoint of in-stent late lumen loss at 9 months by quantitative coronary angiography. Secondary 12-month clinical endpoints are death, target lesion revascularization, target vessel revascularization, myocardial infarction, stent thrombosis and target lesion failure (a composite of cardiac death, target lesion revascularization and target vessel-related myocardial infarction).. The ORIENT trial is the first study to date comparing the Orsiro Hybrid sirolimus-eluting stent with the Resolute Integrity zotarolimus-eluting stent for efficacy and safety in a population of all-comers with coronary artery disease.. Clinicaltrials.gov NCT01826552. Topics: Cardiovascular Agents; Clinical Protocols; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Humans; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Republic of Korea; Research Design; Sirolimus; Time Factors; Treatment Outcome | 2013 |
Long-term luminal change after drug-eluting stent implantation: serial angiographic follow-up study of the ZEST randomized trial.
To evaluate long-term patterns of luminal changes after implantation of different types of drug-eluting stents (DES), we analyzed the serial angiographic outcomes of patients implanted with zotarolimus-eluting stents (ZES), sirolimus-eluting stents (SES), or paclitaxel-eluting stents (PES).. Little is known regarding long-term luminal changes after DES implantation.. As a subgroup analysis of the ZEST trial, we performed complete angiographic evaluation immediately after the procedure and at 9 months and 2 years in 111 patients with 165 lesions (36 patients with ZES, 40 with SES, and 35 with PES).. Baseline clinical, angiographic, and procedural characteristics were similar among the three groups. Quantitative angiographic analysis revealed significant decreases in minimal luminal diameter 9 months after stent implantation in the ZES (from 2.71 ± 0.49 to 2.21 ± 0.42 mm, P < 0.001), SES (from 2.79 ± 0.49 to 2.58 ± 0.57 mm, P < 0.001), and PES (from 2.66 ± 0.45 to 2.19 ± 0.52 mm, P < 0.001) groups. However, significant late improvements with different degree in luminal diameter were observed between 9 months and 2 years in the ZES (from 2.21 ± 0.42 to 2.39 ± 0.58 mm, P = 0.001), SES (from 2.58 ± 0.57 to 2.66 ± 0.60 mm, P = 0.039), and PES (from 2.19 ± 0.52 to 2.43 ± 0.52 mm, P < 0.001) groups.. Serial angiographic follow-up study revealed a biphasic luminal response after DES implantation, characterized by an early progression phase for the first 9 months and a late regression phase from 9 months to 2 years. Topics: Aged; Cardiovascular Agents; Chi-Square Distribution; Coronary Angiography; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Linear Models; Male; Middle Aged; Neointima; Paclitaxel; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Republic of Korea; Single-Blind Method; Sirolimus; Time Factors; Treatment Outcome | 2013 |
Comparison of early strut coverage between zotarolimus- and everolimus-eluting stents using optical coherence tomography.
There have been no optical coherence tomographic (OCT) data directly comparing the pattern of strut coverage between the 2 second-generation drug-eluting stents in the early period. The aim of this prospective study was to evaluate early strut coverage using optical coherence tomography 3 months after Resolute zotarolimus-eluting stent (ZES-R) or everolimus-eluting stent (EES) implantation in de novo coronary artery lesions. A total of 40 patients who were suitable for the OCT procedure and consented to the study protocol were randomized 1:1 to receive either ZES-R or EES. Among these patients, 35 stented lesions (18 ZES-R, 17 EES) in 34 patients were evaluated by optical coherence tomography immediately and 3 months after stent implantation. Neointimal hyperplasia thickness, percentage of uncovered struts, and the proportion of malapposed struts were measured at 1-mm intervals. An uncovered strut was defined as having a neointimal hyperplasia thickness of 0 μm. At the 3-month OCT evaluation, mean neointimal hyperplasia thickness (ZES-R vs EES 74 ± 41 vs 75 ± 35 μm, p = 0.89) and mean percentage of uncovered struts (ZES-R vs EES 6.2 ± 6.9 vs 4.7 ± 5.1%, p = 0.62) were not significantly different between the groups. The percentage of malapposed struts was also similar between the groups (0.7 ± 2.2% for ZES-R and 0.7 ± 1.7% for EES, p = 0.64). Thrombi were documented in 3 stents (1 [5.6%] in a ZES-R vs 2 [11.8%] in EES, p = 0.60). In conclusion, early stent strut coverage on the basis of serial OCT evaluation was comparable between ZES-R and EES 3 months after stent implantation. Topics: Aged; Antineoplastic Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Coronary Vessels; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Neointima; Prospective Studies; Sirolimus; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2013 |
Coronary arterial remodeling and out-stent plaque change after drug-eluting stent implantation--comparison between zotarolimus-eluting stents and paclitaxel-eluting stents.
Out-stent plaque characteristics and eosinophilic inflammatory response, which correlates with positive remodeling after first-generation drug-eluting stent implantation, may be associated with late restenosis and very late stent thrombosis. The differences of out-stent plaque characteristics were compared between paclitaxel-eluting stents (PES) and zotarolimus-eluting stents (ZES), using integrated backscatter-intravascular ultrasound (IB-IVUS).. Of 78 patients enrolled, 25 receiving PES and 25 receiving ZES had adequate IVUS assessment. Volumetric IVUS analysis was performed after stenting and at 8-month follow-up. Out-stent plaque change in the stented segment was compared on IB-IVUS. The relationship between systemic inflammatory response and out-stent plaque change was evaluated. In PES, vessel volume significantly increased (365-389 mm(3), P<0.0001), whereas it did not change in ZES (315-314 mm(3), P=0.81). In culprit lesions at baseline in PES, fibrous plaque tended to increase (3.1-3.6mm(2), P=0.051) and lipid plaque significantly increased (4.3-5.1mm(2), P=0.02), whereas in ZES the fibrous plaque significantly increased (2.9-4.0mm(2), P<0.0001) but lipid plaque significantly decreased (5.1-3.6mm(2), P<0.0001). Systemic eosinophil increase was significantly correlated with positive remodeling and out-stent lipid plaque increase.. Chronic out-stent plaque change in ZES consisted of less positive remodeling and more favorable effects on out-stent plaque characteristics than PES. Systemic eosinophil change might be a marker of out-stent lipid plaque change. Topics: Aged; Aged, 80 and over; Angioplasty, Balloon, Coronary; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Eosinophils; Female; Follow-Up Studies; Humans; Male; Middle Aged; Paclitaxel; Risk Factors; Sirolimus; Treatment Outcome; Tubulin Modulators; Ultrasonography, Interventional; Vasculitis; Ventricular Remodeling | 2013 |
Should duration of dual antiplatelet therapy depend on the type and/or potency of implanted stent? A pre-specified analysis from the PROlonging Dual antiplatelet treatment after Grading stent-induced Intimal hyperplasia studY (PRODIGY).
The purpose of this pre-specified analysis of the PROlonging Dual antiplatelet treatment after Grading stent-induced Intimal hyperplasia studY (PRODIGY) was to assess device-specific outcomes relative to different duration of dual antiplatelet therapy (DAPT) after Everolimus- (EES), Paclitaxel (PES), Zotarolimus- (ZES-S) eluting, or bare metal stents (BMS).. We randomized 2013 patients to BMS, ZES-S, PES, or EES implantation. At 30 days, each stent group underwent up to 6 or 24 months clopidogrel therapy. The primary endpoint, which was a composite of death, myocardial infarction, or cerebrovascular accident, did not differ in patients receiving BMS [HR: 0.89 (95% CI: 0.54-1.45)], PES [HR: 0.74 (95% CI: 0.43-1.25)], or EES [HR: 0.63 (95% CI: 0.33-1.21)] implantation across DAPT groups, whereas it was significantly higher in ZES-S patients undergoing long when compared with short-term DAPT therapy (HR: 2.85, P = 0.0018), with positive interaction testing (P-value = 0.004). At the 6-month landmark analysis, heterogeneity across stent types persisted for the primary study endpoint and other secondary clinical outcomes, whereas patients receiving PES showed a significantly higher rate of definite, probable and definite, probable, possible stent thrombosis in the short DAPT regimen. No association in absolute or relative terms was noted between stent potency in inhibiting intimal hyperplasia and greater vulnerability to shorter DAPT therapy.. Our study suggests that optimal duration of DAPT may be stent-specific and it does not support a clear association between stent potency and vulnerability to shorter DAPT therapy. Trial Registration clinicaltrials.gov Identifier: NCT00611286. http://clinicaltrials.gov/ct2/show/NCT00611286?term=prodigy&rank=2. Topics: Aged; Clopidogrel; Coronary Restenosis; Coronary Vessels; Drug Administration Schedule; Drug Therapy, Combination; Drug-Eluting Stents; Everolimus; Female; Graft Occlusion, Vascular; Humans; Hyperplasia; Male; Myocardial Infarction; Platelet Aggregation Inhibitors; Sirolimus; Stents; Stroke; Ticlopidine; Tunica Intima | 2013 |
Randomized comparison of the efficacy and safety of zotarolimus-eluting stents vs. sirolimus-eluting stents for percutaneous coronary intervention in chronic total occlusion--CAtholic Total Occlusion Study (CATOS) trial.
Limited data are available regarding the direct comparison of angiographic and clinical outcomes after percutaneous coronary intervention (PCI) with drug-eluting stents (DESs) for chronic total occlusion (CTO).. A prospective, randomized, multicenter trial was conducted to evaluate the non-inferiority of a zotarolimus-eluting stent (ZES; Endeavor Sprint®, n=80) to a sirolimus-eluting stent (SES; Cypher®, n=80) in patients with CTO lesion with a reference vessel diameter ≥ 2.5mm. The primary endpoint was in-segment binary restenosis rate at 9-month angiographic follow-up. Key secondary endpoints included target vessel failure (TVF; including cardiac death, myocardial infarction, and target vessel revascularization) and Academic Research Consortium-defined definite/probable stent thrombosis (ST) within 12 months. The ZES was non-inferior to the SES with respect to the primary endpoint, which occurred in 14.1% (95% confidence interval [CI]: 6.0-22.2) and in 13.7% (95%CI: 5.8-21.6) of patients, respectively (non-inferiority margin, 15.0%; P for non-inferiority <0.001). There were no significant between-group differences in the rate of TVF (10.0% vs. 17.5%; P=0.168) nor in the rate of ST (0.0% vs. 1.3%; P=0.316) during the 12-month clinical follow-up.. The effectiveness and safety of ZES are similar to those of SES and therefore it is a good treatment option in patients undergoing PCI for CTO with DESs. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chronic Disease; Coronary Angiography; Coronary Occlusion; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Prospective Studies; Prosthesis Design; Republic of Korea; Sirolimus; Thrombosis; Time Factors; Treatment Outcome; Ultrasonography, Interventional | 2012 |
Short- versus long-term duration of dual-antiplatelet therapy after coronary stenting: a randomized multicenter trial.
The optimal duration of dual-antiplatelet therapy and the risk-benefit ratio for long-term dual-antiplatelet therapy after coronary stenting remain poorly defined. We evaluated the impact of up to 6 versus 24 months of dual-antiplatelet therapy in a broad all-comers patient population receiving a balanced proportion of Food and Drug Administration-approved drug-eluting or bare-metal stents.. We randomly assigned 2013 patients to receive bare-metal, zotarolimus-eluting, paclitaxel-eluting, or everolimus-eluting stent implantation. At 30 days, patients in each stent group were randomly allocated to receive up to 6 or 24 months of clopidogrel therapy in addition to aspirin. The primary end point was a composite of death of any cause, myocardial infarction, or cerebrovascular accident. The cumulative risk of the primary outcome at 2 years was 10.1% with 24-month dual-antiplatelet therapy compared with 10.0% with 6-month dual-antiplatelet therapy (hazard ratio, 0.98; 95% confidence interval, 0.74-1.29; P=0.91). The individual risks of death, myocardial infarction, cerebrovascular accident, or stent thrombosis did not differ between the study groups; however, there was a consistently greater risk of hemorrhage in the 24-month clopidogrel group according to all prespecified bleeding definitions, including the recently proposed Bleeding Academic Research Consortium classification.. A regimen of 24 months of clopidogrel therapy in patients who had received a balanced mixture of drug-eluting or bare-metal stents was not significantly more effective than a 6-month clopidogrel regimen in reducing the composite of death due to any cause, myocardial infarction, or cerebrovascular accident.. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00611286. Topics: Aged; Aged, 80 and over; Aspirin; Cause of Death; Clopidogrel; Coronary Restenosis; Coronary Vessels; Drug Therapy, Combination; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Middle Aged; Myocardial Infarction; Paclitaxel; Platelet Aggregation Inhibitors; Risk; Sirolimus; Stroke; Thrombosis; Ticlopidine; Treatment Outcome | 2012 |
Zotarolimus-eluting vs. sirolimus-eluting coronary stents in patients with and without acute coronary syndromes: a SORT OUT III substudy.
To compare clinical outcomes among patients with acute coronary syndrome treated with zotarolimus-eluting and sirolimus-eluting stents in the SORT OUT III trial.. Currently, only limited data allow direct comparison of clinical outcomes among patients with acute coronary syndrome treated with a second-generation drug-eluting stent (DES) eluting zotarolimus vs. a first-generation DES eluting sirolimus.. Patients with acute coronary syndrome (n=1052) were randomized to treatment with zotarolimus-eluting (n=506) or sirolimus-eluting (n=546) stents and followed for 18 months. The primary composite endpoint, major adverse cardiac events (MACE), was defined as a composite of cardiac death, myocardial infarction or target vessel revascularization.. Zotarolimus-eluting stent treatment compared to sirolimus-eluting stent treatment was associated with increased rates of MACE (8·7% vs. 5·0%; hazard ratio (HR), 1·78; 95% confidence interval (CI), 1·10-2·88; P=0·02) and TVR (6·8% vs. 3·9%; HR, 1·77; 95% CI, 1·03-3·04; P=0·04), while all-cause death, cardiac death, myocardial infarction and definite stent thrombosis did not differ significantly. In the same trial, stable angina pectoris patients (n=1206) were randomized to zotarolimus-eluting (n=614) and sirolimus-eluting (n=592) stents with similar results.. With and without acute coronary syndromes, patients treated with the sirolimus-eluting stent had better clinical outcomes than those treated with the zotarolimus-eluting stent. Topics: Acute Coronary Syndrome; Angina, Stable; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Myocardial Infarction; Myocardial Revascularization; Sirolimus; Treatment Outcome | 2012 |
Stent thrombosis and major clinical events at 3 years after zotarolimus-eluting or sirolimus-eluting coronary stent implantation: a randomised, multicentre, open-label, controlled trial.
We sought to compare the long-term safety of two devices with different antiproliferative properties: the Endeavor zotarolimus-eluting stent (E-ZES; Medtronic, Inc) and the Cypher sirolimus-eluting stent (C-SES; Cordis, Johnson & Johnson) in a broad group of patients and lesions.. Between May 21, 2007 and Dec 22, 2008, we recruited 8791 patients from 36 recruiting countries to participate in this open-label, multicentre, randomised, superiority trial. Eligible patients were those aged 18 years or older undergoing elective, unplanned, or emergency procedures in native coronary arteries. Patients were randomly assigned to either receive E-ZES and C-SES (ratio 1:1). Randomisation was stratified per centre with varying block sizes of four, six, or eight patients, and concealed with a central telephone-based or web-based allocation service. The primary outcome was definite or probable stent thrombosis at 3 years and was analysed by intention to treat. Patients and investigators were aware of treatment assignment. This trial is registered with ClinicalTrials.gov, number NCT00476957.. PROTECT randomised 8791 patients, of whom 8709 provided consent to participate and were eligible: 4357 were allocated to the E-ZES group and 4352 patients to the C-SES group. At 3 years, rates of definite or probable stent thrombosis did not differ between groups (1·4% for E-ZES [predicted: 1·5%] vs 1·8% [predicted: 2·5%] for C-SES; hazard ratio [HR] 0·81, 95% CI 0·58-1·14, p=0·22). Dual antiplatelet therapy was used in 8402 (96%) patients at discharge, 7456 (88%) at 1 year, 3041 (37%) at 2 years, and 2364 (30%) at 3 years.. No evidence of superiority of E-ZES compared with C-SES in definite or probable stent thrombosis rates was noted at 3 years. Time analysis suggests a difference in definite or probable stent thrombosis between groups is emerging over time, and a longer follow-up is therefore needed given the clinical relevance of stent thrombosis.. Medtronic, Inc. Topics: Aged; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Sirolimus; Thrombosis | 2012 |
Comparison of resolute zotarolimus-eluting stents and sirolimus-eluting stents in patients with de novo long coronary artery lesions: a randomized LONG-DES IV trial.
Procedural and clinical outcomes still remain unfavorable for patients with long coronary lesions who undergo stent-based coronary interventions. Therefore, we compared the relative efficacy and safety of resolute zotarolimus-eluting stents (R-ZES) and sirolimus-eluting stents (SES) for patients with de novo long coronary lesions.. This randomized, multicenter, prospective trial, called the Percutaneous Treatment of LONG Native Coronary Lesions With Drug-Eluting Stent-IV (LONG-DES IV) trial, compared long R-ZES and SES in 500 patients with long (≥25 mm) native coronary lesions. The primary end point of the trial was in-segment late luminal loss at 9-month angiographic follow-up. The baseline characteristics were not different between R-ZES and SES groups, including lesion lengths (32.4±13.5 mm versus 31.0±13.5 mm, P=0.27). At 9-month angiographic follow-up, the R-ZES was noninferior to the SES with respect to in-segment late luminal loss, the primary study end point (0.14±0.38 mm versus 0.12±0.43 mm, P for noninferiority=0.03, P for superiority=0.68). In addition, in-stent late luminal loss (0.26±0.36 mm versus 0.24±0.42 mm, P=0.78) and the rates of in-segment (5.2% versus 7.2%, P=0.44) and in-stent (4.0% versus 6.0%, P=0.41) binary restenosis were not significantly different between the 2 groups. There were no significant between-group differences in the rate of adverse clinical events (death, myocardial infarction, stent thrombosis, target-lesion revascularization, and composite outcomes).. For patients with de novo long coronary artery disease, R-ZES implantation showed noninferior angiographic outcomes as compared with SES implantation.. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01186094. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chi-Square Distribution; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Prospective Studies; Prosthesis Design; Republic of Korea; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2012 |
Unrestricted randomised use of two new generation drug-eluting coronary stents: 2-year patient-related versus stent-related outcomes from the RESOLUTE All Comers trial.
In the RESOLUTE All Comers trial, the Resolute zotarolimus-eluting stent was non-inferior to the Xience V everolimus-eluting stent for the primary stent-related endpoint of target lesion failure (cardiac death, target vessel myocardial infarction, and ischaemia-driven target lesion revascularisation) at 1 year. However, data for long-term safety and efficacy from randomised studies of new generation drug-eluting coronary stents in patients treated in routine clinical practice are scarce. We report the prespecified 2-year clinical outcomes from the RESOLUTE All Comers trial.. In 2008, patients with at least one coronary lesion 2.25-4.0 mm in diameter, with greater than 50% stenosis, were randomly assigned to a Resolute zotarolimus-eluting stent or a Xience V everolimus-eluting stent at 17 centres in Europe and Israel. Randomisation was by an interactive voice response system stratified by centre. Study investigators were not masked to treatment allocation; but those who did data management and analysis, and patients were masked. There were no restrictions as to the number of vessels or lesions treated, or the number of stents implanted. We assessed prespecified safety and efficacy outcomes at 2 years with specific focus on patient-related composite (all death, all myocardial infarction, all revascularisation) and stent-related composite outcomes. Analyses were by intention to treat. This study is registered with ClinicalTrials.gov, number NCT00617084.. 1140 patients were assigned to the zotarolimus-eluting stent and 1152 to the everolimus-eluting stent; 1121 and 1128 patients, respectively, completed 2-year follow-up. The patient-related outcome (231 [20.6%] zotarolimus vs 231 [20.5%] everolimus; difference 0.1%, 95% CI-3.2 to 3.5; p=0.958) and stent-related outcome (126 [11.2%] vs 121 [10.7%]; difference 0.5%, -2.1 to 3.1; p=0.736) did not differ between groups, although rates of the stent-related outcome were substantially lower than were those for the patient-related outcome. Three patients in each group (0.3%) had very late (after 1 year) stent thrombosis.. Similar safety and efficacy outcomes were sustained between two new generation drug-eluting stents at 2-year follow-up. The greater number of patient-related than stent-related events in patients with complex clinical and lesion characteristics emphasises that during long-term follow-up, the optimisation of secondary prevention is at least as important as the selection of which new generation drug-eluting stent to implant in a specific lesion.. Medtronic (USA). Topics: Adult; Aged; Confounding Factors, Epidemiologic; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Death, Sudden, Cardiac; Drug-Eluting Stents; Europe; Everolimus; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Israel; Male; Middle Aged; Myocardial Infarction; Myocardial Revascularization; Prospective Studies; Secondary Prevention; Sirolimus; Treatment Outcome | 2011 |
Clinical evaluation of the Resolute zotarolimus-eluting coronary stent system in the treatment of de novo lesions in native coronary arteries: the RESOLUTE US clinical trial.
The RESOLUTE US (R-US) trial is a prospective, observational study designed to evaluate the clinical effectiveness of the Resolute zotarolimus-eluting stent (R-ZES) in a U.S. population.. The R-ZES releases zotarolimus over a 6-month period in order to achieve optimal clinical effectiveness and safety.. The R-US trial recruited patients with de novo native coronary lesions suitable for 1- or 2-vessel treatment with stents from 2.25 to 4.0 mm in diameter. In the main analysis cohort (2.5- to 3.5-mm stents and single-lesion treatment), the primary endpoint was 12-month target lesion failure (TLF) defined as the composite of cardiac death, myocardial infarction (MI), and clinically-driven target lesion revascularization (TLR), compared with data from Endeavor zotarolimus-eluting stent (E-ZES) trials, adjusting for baseline covariates through propensity scores.. Overall, 1,402 patients were enrolled with a mean reference vessel diameter of 2.59 ± 0.47 mm and diabetes prevalence of 34.4%. In the main analysis cohort, TLF was 3.7% at 12 months compared with historical E-ZES results (TLF = 6.5%). The R-ZES met the 3.3% margin of noninferiority (rate difference = -2.8%, upper 1-sided 95% confidence interval: -1.3%, p < 0.001). The overall TLF rate was 4.7%, and rates of cardiac death, MI, and TLR were 0.7%, 1.4%, and 2.8%, respectively. The 12-month rate of stent thrombosis was 0.1%.. The R-ZES achieved a very low rate of clinical restenosis while maintaining low rates of important clinical safety events such as death, MI, and stent thrombosis at 1-year follow-up. (The Medtronic RESOLUTE US Clinical Trial [R-US]; NCT00726453). Topics: Aged; Cohort Studies; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Diabetes Mellitus; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Prevalence; Prospective Studies; Sirolimus; Treatment Outcome; United States | 2011 |
The prognostic utility of the SYNTAX score on 1-year outcomes after revascularization with zotarolimus- and everolimus-eluting stents: a substudy of the RESOLUTE All Comers Trial.
This study assessed the ability of the SYNTAX score (SXscore) to stratify risk in patients treated with percutaneous coronary intervention (PCI) using zotarolimus-eluting or everolimus-eluting stents.. The SXscore can identify patients treated with PCI who are at highest risk of adverse events.. The SXscore was calculated prospectively in 2,033 of the 2,292 patients enrolled in the RESOLUTE All Comers study (RESOLUTE III All Comers Trial: A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention). Clinical outcomes in terms of a patient-oriented composite endpoint (POCE) of all-cause death, myocardial infarction (MI), and repeat revascularization; the individual components of POCE; target lesion failure (TLF) (a composite of cardiac death, target-vessel MI, and clinically driven target lesion revascularization); and stent thrombosis were subsequently stratified according to SXscore tertiles: SXscore(LOW) ≤ 9 (n = 698), 9 Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Europe; Everolimus; Female; Health Status Indicators; Humans; Israel; Kaplan-Meier Estimate; Linear Models; Male; Middle Aged; Myocardial Infarction; Predictive Value of Tests; Proportional Hazards Models; Prospective Studies; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Survival Rate; Time Factors; Treatment Outcome | 2011 |
Late-term clinical outcomes with zotarolimus- and sirolimus-eluting stents. 5-year follow-up of the ENDEAVOR III (A Randomized Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Cypher Sirolimus-Eluting Coro
This study sought to compare late safety and efficacy outcomes following percutaneous coronary revascularization with zotarolimus-eluting stents (ZES) and sirolimus-eluting stents (SES).. Despite higher late lumen loss and binary restenosis with ZES compared with SES, it is uncertain whether differences in early angiographic measures translate into more disparate late clinical events.. Clinical outcomes were prospectively evaluated through 5 years in the ENDEAVOR III (A Randomized Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Cypher Sirolimus-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions) that randomized 436 patients of relatively low anatomic and clinical risk to treatment with ZES (n = 323) or SES (n = 113) and evaluated a primary endpoint of 8-month angiographic late lumen loss.. At 5 years (completeness of follow-up: 95.2%), pre-specified endpoints of all-cause mortality (5.2% vs. 13.0%, p = 0.02), myocardial infarction (1.0% vs. 4.6%, p = 0.03), and the composite event rates of cardiac death/myocardial infarction (1.3% vs. 6.5%, p = 0.009) and major adverse cardiac events (14.0% vs. 22.2%, p = 0.05) were significantly lower among patients treated with ZES. Rates of target lesion (8.1% ZES vs. 6.5% SES, p = 0.68) and target vessel revascularization were similar between treatment groups. Stent thrombosis was infrequent and similar in both groups (0.7% ZES vs. 0.9% SES, p = 1.0). Between 9 months and 5 years, progression of major adverse cardiac events was significantly more common with SES than with ZES (16.7% vs. 7.8%, p = 0.015).. Despite initially higher angiographic late lumen loss, rates of clinical restenosis beyond the protocol-specified angiographic follow-up period remain stable with ZES compared with the rates for SES, resulting in similar late-term efficacy. Over 5 years, significant differences in death, myocardial infarction, and composite endpoints favored treatment with ZES. (The Medtronic Endeavor III Drug Eluting Coronary Stent System Clinical Trial [ENDEAVOR III]; NCT00217256). Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Prospective Studies; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2011 |
Late lumen loss and intima hyperplasia after sirolimus-eluting and zotarolimus-eluting stent implantation in diabetic patients: the diabetes and drug-eluting stent (DiabeDES III) angiography and intravascular ultrasound trial.
Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent implantation due to neointimal hyperplasia (NIH). The aim of this study was to use quantitative coronary angiography (QCA) and volumetric intravascular ultrasound (IVUS) to evaluate the effects of the sirolimus-eluting Cypher® stent (SES) and the zotarolimus-eluting Endeavor® stent (ZES) on angiographic late lumen loss and intima hyperplasia in diabetic patients.. In the DiabeDES III trial, 127 patients were randomised to SES or ZES stent implantation. Angiographic 10-month follow-up data were available in 105 patients, including 48 SES and 57 ZES treated patients. Angiographic endpoints were in-stent late lumen loss and minimal lumen diameter. IVUS endpoints included NIH volume and in-stent percent volume obstruction. Baseline clinical characteristics and lesion parameters were similar in the two groups. At 10-month follow-up, angiographic in-stent late lumen loss (0.14±0.37 mm vs. 0.74±0.45 mm, p<0.001) was reduced and minimum lumen diameter was higher (2.36±0.53 mm vs. 1.96±0.65, p<0.001) in the SES group as compared to the ZES group. As compared to the ZES group, NIH volume was significantly reduced in the SES group (median [interquartile range]: 0.0 mm3 [0.0 to 1.2] vs. 16.5 mm3 [6.2 to 31.1], p<0.001). In-stent% volume obstruction was significantly reduced in SES as compared to ZES (median [interquartile range]: 0.0% [0.0-0.7] vs. 13.0% [6.7-20.8], p<0.001).. In diabetic patients, the SES reduced angiographic late lumen loss and inhibited NIH more effectively than ZES. Topics: Aged; Angioplasty, Balloon, Laser-Assisted; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Diabetes Complications; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Hyperplasia; Male; Middle Aged; Neointima; Risk Factors; Single-Blind Method; Sirolimus; Treatment Outcome; Ultrasonography, Interventional | 2011 |
Sex differences in neointimal hyperplasia following endeavor zotarolimus-eluting stent implantation.
Inconsistent results in outcomes have been observed between the genders after drug-eluting stent implantation. The aim of this study was to investigate gender differences in neointimal proliferation for the Endeavor zotarolimus-eluting stent (ZES) and the Driver bare-metal stent (BMS). A total of 476 (n = 391 ZES, n = 85 BMS) patients whose volumetric intravascular ultrasound analyses were available at 8-month follow-up were studied. At 8 months, neointimal obstruction and maximum cross-sectional narrowing (CSN) were significantly lower in women than in men receiving ZES (neointimal obstruction 15.5 ± 9.5% vs 18.2 ± 10.9%, p = 0.025; maximum CSN 30.3 ± 13.2% vs 34.8 ± 15.0%, p = 0.007). Conversely, these parameters tended to be higher in women than in men receiving BMS (neointimal obstruction 36.3 ± 15.9% vs 27.5 ± 17.2%, p = 0.053; maximum CSN 54.3 ± 18.6% vs 45.6 ± 18.3%, p = 0.080). There was a significant interaction between stent type and gender regarding neointimal obstruction (p = 0.001) and maximum CSN (p = 0.003). Multivariate linear regression analysis revealed that female gender was independently associated with lower neointimal obstruction (p = 0.027) and maximum CSN (p = 0.004) for ZES but not for BMS. Compared to BMS, ZES were independently associated with a reduced risk for binary restenosis in both genders (odds ratio for women 0.003, p = 0.001; odds ratio for men 0.191, p <0.001), but the magnitude of this risk reduction with ZES was significantly greater in women than men (p = 0.015). In conclusion, female gender is independently associated with decreased neointimal hyperplasia in patients treated with ZES. The magnitude of risk reduction for binary restenosis with ZES is significantly greater in women than in men. Topics: Angioplasty, Balloon, Coronary; California; Coronary Restenosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Hyperplasia; Male; Middle Aged; Myocardial Infarction; Neointima; Prognosis; Prosthesis Design; Retrospective Studies; Risk Factors; Sex Distribution; Sex Factors; Sirolimus | 2011 |
Efficacy and safety of zotarolimus-eluting and sirolimus-eluting coronary stents in routine clinical care (SORT OUT III): a randomised controlled superiority trial.
In low-risk patients, the zotarolimus-eluting stent has been shown to reduce rates of restenosis without increasing the risk of stent thrombosis. We compared the efficacy and safety of the zotarolimus-eluting stent versus the sirolimus-eluting stent in patients with coronary artery disease who were receiving routine clinical care with no direct follow-up.. We did a single-blind, all-comer superiority trial in adult patients with chronic stable coronary artery disease or acute coronary syndromes, and at least one target lesion. Patients were treated at one of five percutaneous coronary intervention centres between January, 2006, and August, 2007. Computer-generated block randomisation and a telephone allocation service were used to randomly assign patients to receive the zotarolimus-eluting or the sirolimus-eluting stent. Data for follow-up were obtained from national Danish administrative and health-care registries. The primary endpoint was a composite of major adverse cardiac events within 9 months: cardiac death, myocardial infarction, and target vessel revascularisation. Intention-to-treat analyses were done at 9-month and 18-month follow-up. This trial is registered with ClinicalTrials.gov, number NCT00660478.. 1162 patients (1619 lesions) were assigned to receive the zotarolimus-eluting stent, and 1170 patients (1611 lesions) to receive the sirolimus-eluting stent. 67 patients (72 lesions) had stent failure, and six patients were lost to follow-up. All randomly assigned patients were included in analyses at 9-month follow-up; 2200 patients (94%) had completed 18-month follow-up by the time of our assessment. At 9 months, the primary endpoint had occurred in a higher proportion of patients treated with the zotarolimus-eluting stent than in those treated with the sirolimus-eluting stent (72 [6%] vs 34 [3%]; HR 2.15, 95% CI 1.43-3.23; p=0.0002). At 18-month follow-up, this difference was sustained (113 [10%] vs 53 [5%]; 2.19, 1.58-3.04; p<0.0001). For patients receiving the zotarolimus-eluting stent and those receiving the sirolimus-eluting stent, all cause-mortality was similar at 9-month follow-up (25 [2%] vs 18 [2%]; 1.40, 0.76-2.56; p=0.28), but was significantly different at 18-month follow-up (51 [4%] vs 32 [3%]; 1.61, 1.03-2.50; p=0.035).. The sirolimus-eluting stent is superior to the zotarolimus-eluting stent for patients receiving routine clinical care.. Cordis and Medtronic. Topics: Aged; Angioplasty, Balloon, Coronary; Coronary Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Retreatment; Single-Blind Method; Sirolimus; Thrombosis; Treatment Outcome | 2010 |
Eighteen-month clinical safety and efficacy outcomes of sirolimus-, paclitaxel- and zotarolimus-drug eluting stents in diabetic patients undergoing percutaneous coronary intervention for complex coronary artery stenosis.
This was a single centre registry study on clinical efficacy and safety of drug-eluting stent (DES) in diabetic patients undergoing percutaneous coronary intervention (PCI) for complex coronary lesions.. A total of 288 diabetic patients who underwent elective PCI between September 2003 and June 2006 in our centre were enrolled and followed-up for 18 months. Among them, 79 (27.4%) patients received sirolimus-eluting stent (SES), 138 (47.9%) paclitaxel-eluting stent (PES) and 71 (24.7%) zotarolimus-eluting stent (ZES). The endpoints were major adverse cardiac events (MACE) and stent thrombosis rates.. Baseline demographics were comparable among the 3 DES groups (median age was 60 years; 69% men). Complex lesions (defined as ACC/AHA type C stenosis) accounted for 55.6% of the total lesions: SES (50.6%), PES (65.2%) and ZES (43.7%), P = 0.005. At 18 months follow-up, the composite endpoint of MACE was found in 12.7% in SES group, 8.7% in the PES group, 12.7% in ZES group and (P = 0.55). Stent thrombosis (ST) occurred in 1 patient (1.3%) in the SES group, 2 patients (1.4%) in PES group and 1 patient (1.4%) in ZES group, respectively (P = 1.00).. The use of DES for elective PCI in diabetic patients was associated with favourable intermediate-term clinical outcomes with no significant differences in efficacy among the 3 groups. Stent thrombosis had low event occurrence rate. Topics: Aged; Angioplasty, Balloon, Coronary; Coronary Restenosis; Coronary Stenosis; Diabetes Complications; Drug-Eluting Stents; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Myocardial Infarction; Paclitaxel; Sirolimus; Survival Analysis; Treatment Outcome | 2010 |
Comparison of zotarolimus-eluting and everolimus-eluting coronary stents.
New-generation coronary stents that release zotarolimus or everolimus have been shown to reduce the risk of restenosis. However, it is unclear whether there are differences in efficacy and safety between the two types of stents on the basis of prospectively adjudicated end points endorsed by the Food and Drug Administration.. In this multicenter, noninferiority trial with minimal exclusion criteria, we randomly assigned 2292 patients to undergo treatment with coronary stents releasing either zotarolimus or everolimus. Twenty percent of patients were randomly selected for repeat angiography at 13 months. The primary end point was target-lesion failure, defined as a composite of death from cardiac causes, any myocardial infarction (not clearly attributable to a nontarget vessel), or clinically indicated target-lesion revascularization within 12 months. The secondary angiographic end point was the extent of in-stent stenosis at 13 months.. At least one off-label criterion for stent placement was present in 66% of patients. The zotarolimus-eluting stent was noninferior to the everolimus-eluting stent with respect to the primary end point, which occurred in 8.2% and 8.3% of patients, respectively (P<0.001 for noninferiority). There were no significant between-group differences in the rate of death from cardiac causes, any myocardial infarction, or revascularization. The rate of stent thrombosis was 2.3% in the zotarolimus-stent group and 1.5% in the everolimus-stent group (P=0.17). The zotarolimus-eluting stent was also noninferior regarding the degree (+/-SD) of in-stent stenosis (21.65+/-14.42% for zotarolimus vs. 19.76+/-14.64% for everolimus, P=0.04 for noninferiority). In-stent late lumen loss was 0.27+/-0.43 mm in the zotarolimus-stent group versus 0.19+/-0.40 mm in the everolimus-stent group (P=0.08). There were no significant between-group differences in the rate of adverse events.. At 13 months, the new-generation zotarolimus-eluting stent was found to be noninferior to the everolimus-eluting stent in a population of patients who had minimal exclusion criteria. (ClinicalTrials.gov number, NCT00617084.) Topics: Aged; Coronary Angiography; Coronary Disease; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Female; Humans; Intention to Treat Analysis; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Prosthesis Design; Retreatment; Sirolimus; Treatment Failure | 2010 |
Comparison of zotarolimus-eluting stents with sirolimus- and paclitaxel-eluting stents for coronary revascularization: the ZEST (comparison of the efficacy and safety of zotarolimus-eluting stent with sirolimus-eluting and paclitaxel-eluting stent for cor
The aim of this study was to evaluate the relative efficacy and safety of zotarolimus-eluting stents (ZES) in comparison with the established and widely used sirolimus- (SES) and paclitaxel-eluting stents (PES) in routine clinical practice.. Whether ZES might provide similar clinical and angiographic outcomes in a broad spectrum of patients compared with SES or PES is undetermined.. We performed a single-blind, multicenter, prospectively randomized trial to compare ZES with SES and PES in 2,645 patients undergoing percutaneous coronary intervention. The primary end point was a composite of major adverse cardiac events (MACE) (death, myocardial infarction, and ischemia-driven target vessel revascularization) at 12 months. A noninferiority comparison (ZES vs. SES) and a superiority comparison (ZES vs. PES) were performed for the primary end point.. Baseline clinical and angiographic characteristics were similar in the 3 groups. At 12 months, the ZES group showed noninferior rates of MACE compared with the SES group (10.2% vs. 8.3%, p for noninferiority = 0.01, p for superiority = 0.17) and significantly fewer MACE than the PES group (10.2% vs. 14.1%, p for superiority = 0.01). The incidence of death or myocardial infarction was similar among the groups (ZES vs. SES vs. PES, 5.8% vs. 6.9% vs. 7.6%, respectively, p = 0.31). The incidence of stent thrombosis was significantly lower in the SES group (ZES vs. SES vs. PES, 0.7% vs. 0% vs. 0.8%, respectively, p = 0.02).. In this large-scale, practical randomized trial, the use of ZES resulted in similar rates of MACE compared with SES and in fewer MACE compared with PES at 12 months. (Comparison of the Efficacy and the Safety of Zotarolimus-Eluting Stent Versus Sirolimus-Eluting Stent and PacliTaxel-Eluting Stent for Coronary Lesions; NCT00418067). Topics: Aged; Cardiovascular Diseases; Coronary Restenosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Myocardial Reperfusion; Paclitaxel; Prospective Studies; Single-Blind Method; Sirolimus; Treatment Outcome | 2010 |
Improved late clinical safety with zotarolimus-eluting stents compared with paclitaxel-eluting stents in patients with de novo coronary lesions: 3-year follow-up from the ENDEAVOR IV (Randomized Comparison of Zotarolimus- and Paclitaxel-Eluting Stents in
The increased frequency of very late (>1 year) stent thrombosis (VLST) has raised concerns with regard to the safety of sirolimus-eluting stents and paclitaxel-eluting stents (PES).. Experimental and preliminary clinical findings with the zotarolimus-eluting stent (ZES) have suggested a favorable safety profile.. The ENDEAVOR IV (Randomized Comparison of Zotarolimus- and Paclitaxel-Eluting Stents in Patients With Coronary Artery Disease) trial is a single-blind randomized ZES versus PES clinical trial in 1,548 patients with de novo native coronary lesions; the primary end point-9-month target vessel failure-was previously reported, annual clinical follow-up is planned for 5 years, and this report describes the 3-year outcomes.. The ZES compared with PES reduced target vessel failure (12.3% vs. 15.9%, hazard ratio [HR]: 0.76, 95% confidence interval [CI]: 0.58 to 1.00, p = 0.049), myocardial infarctions (MI) (2.1% vs. 4.9%, HR: 0.44, 95% CI: 0.25 to 0.80, p = 0.005), and cardiac death plus MI (3.6% vs. 7.1%, HR: 0.52, 95% CI 0.32 to 0.82, p = 0.004). Although the overall 3-year rate of Academic Research Consortium definite/probable stent thrombosis did not differ significantly (1.1% vs. 1.7%, HR: 0.67, 95% CI 0.28 to 1.64, p = 0.380), VLST (between 1 and 3 years) was significantly reduced in ZES patients (1 event vs. 11 events; 0.1% vs. 1.6%, HR: 0.09, 95% CI: 0.01 to 0.71, p = 0.004). Ischemia-driven target lesion revascularization at 3 years was similar with ZES versus PES (6.5% vs. 6.1%, HR: 1.10, 95% CI: 0.73 to 1.65, p = 0.662).. Three-year follow-up results from the ENDEAVOR IV trial indicate similar antirestenosis efficacy but improved clinical safety associated with ZES compared with PES, due to significantly fewer peri-procedural and remote MIs associated with fewer VLST events. (A Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions; NCT00217269). Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Paclitaxel; Platelet Aggregation Inhibitors; Proportional Hazards Models; Prospective Studies; Prosthesis Design; Risk Assessment; Risk Factors; Single-Blind Method; Sirolimus; Thrombosis; Time Factors; Treatment Outcome; United States | 2010 |
Cellular and molecular changes associated with inhibitory effect of pioglitazone on neointimal growth in patients with type 2 diabetes after zotarolimus-eluting stent implantation.
To investigate the mechanistic basis underlying antirestenosis and the antiatherogenic effect of pioglitazone in patients with type 2 diabetes mellitus who were undergoing zotarolimus-eluting stent implantation.. Recent studies highlight the beneficial effect of pioglitazone in attenuating neointimal growth after stent implantation. Patients with coronary artery diseases were randomly assigned to pioglitazone (n=47) or placebo (n=47) after stent implantation. Pioglitazone significantly reduced neointimal hyperplasia within the stented lesion and attenuated total plaque burden in the in-segment regions of the stent, as assessed by intravascular ultrasonography at the 8-month follow-up. These changes were preceded by reduced circulating natural killer (NK) cells, diminished interleukin 6 and monocyte chemoattractant protein-1 levels, and downregulation of chemokine receptor 2 at 2 days after stent implantation; and an elevated interleukin 10 level at 10 days after implantation. Furthermore, the proliferation and migration of vascular smooth muscle cells were inhibited in the presence of pioglitazone-treated patient serum, demonstrating that the antiproliferative effects of pioglitazone occurred concurrently with its antiinflammatory action.. Our data present early cellular and immunologic changes by pioglitazone that might have been associated with antirestenotic and antiatherogenic effects in diabetic patients. Inhibiting proinflammatory responses while promoting antiinflammatory circuits, together with an antiproliferative action, may, in part, account for the antirestenotic effect of pioglitazone by altering vascular remodeling processes in the early phase. Topics: Adult; Aged; Angioplasty, Balloon, Coronary; Biomarkers; Blood Glucose; Cardiovascular Agents; Cell Movement; Cell Proliferation; Cells, Cultured; Chemokine CCL2; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Diabetes Mellitus, Type 2; Dose-Response Relationship, Drug; Drug-Eluting Stents; Female; Glycated Hemoglobin; Humans; Hyperplasia; Hypoglycemic Agents; Inflammation Mediators; Insulin; Interleukin-6; Killer Cells, Natural; Lipids; Male; Middle Aged; Myocytes, Smooth Muscle; Pioglitazone; Prospective Studies; Prosthesis Design; Receptors, CCR2; Republic of Korea; Single-Blind Method; Sirolimus; Thiazolidinediones; Time Factors; Treatment Outcome; Tunica Intima; Ultrasonography, Interventional | 2010 |
A prospective, randomized, 6-month comparison of the coronary vasomotor response associated with a zotarolimus- versus a sirolimus-eluting stent: differential recovery of coronary endothelial dysfunction.
We prospectively compared coronary endothelial dysfunction in patients with zotarolimus-eluting stent (ZES) versus sirolimus-eluting stent (SES) implantation at 6-month follow-up.. A ZES has been associated with uniform and rapid healing of the endothelium.. Fifty patients were randomly treated with intravascular ultrasound-guided stenting with a single stent to the mid-segment of the left anterior descending artery (20 ZES, 20 SES, and 10 bare-metal stents), and endothelial function was estimated before and after intervention at 6-month follow-up by incremental acetylcholine (Ach) (10, 20, 50, and 100 microg/min) and nitrate (200 microg/min) infusions into the left coronary ostium. The vascular response was quantitatively measured in the 5-mm segments proximal and distal to the stent.. In the drug-eluting stent groups, more intense vasoconstriction to incremental doses of Ach was observed at 6-month follow-up compared with the responses before stenting. Endothelial function associated with the ZES was more preserved at 6-month follow-up compared with the SES. Vasoconstriction to Ach was more prominent in the distal segments than the proximal segments in both the ZES and SES groups. Endothelium-independent vasodilation to nitrate did not differ significantly among the study groups.. Vasoconstriction in response to Ach in the peri-stent region was less pronounced in the ZES group than the SES group at 6-month follow-up, which suggests that endothelial function associated with ZES can be more preserved than the SES. Topics: Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Endothelium, Vascular; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Prospective Studies; ROC Curve; Sirolimus; Time Factors; Vasoconstriction | 2009 |
Intravascular ultrasound results from the ENDEAVOR IV trial: randomized comparison between zotarolimus- and paclitaxel-eluting stents in patients with coronary artery disease.
The aim of this study was to compare the vessel response between zotarolimus-eluting stents (ZES) and paclitaxel-eluting stents (PES) using intravascular ultrasound.. The ENDEAVOR IV (Randomized Comparison of Zotarolimus- and Paclitaxel-Eluting Stents in Patients With Coronary Artery Disease) trial was a randomized controlled study of zotarolimus-eluting, phosphorylcholine-coated, cobalt-alloy stents for the treatment of de novo coronary lesions compared with using PES for the same treatment.. Data were obtained from patients with serial (baseline and 8-months follow-up) intravascular ultrasound analysis available (n = 198). Volumetric analysis was performed for vessel, lumen, plaque, stent, and neointima. Cross-sectional narrowing (given as percentage) was defined as neointimal area divided by stent area. Neointima-free frame ratio was calculated as the number of frames without intravascular ultrasound-detectable neointima divided by the total number of frames within the stent. Subsegment analysis was performed at every matched 1-mm subsegment throughout the stent.. At follow-up, the ZES group showed significantly greater percentage of neointimal obstruction (16.6 +/- 12.0% vs. 9.9 +/- 8.9%, p < 0.01) and maximum cross-sectional narrowing (31.8 +/- 16.1% vs. 25.2 +/- 14.9%, p < 0.01) with smaller minimum lumen area than the PES group did. However, the incidence of maximum cross-sectional narrowing >50% was similar in the 2 groups. Neointima-free frame ratio was significantly lower in the ZES group. In overall analysis, whereas the PES group showed positive remodeling during follow-up (13.7 +/- 4.2 mm(3)/mm to 14.3 +/- 4.3 mm(3)/mm), the ZES group showed no significant difference (12.7 +/- 3.6 mm(3)/mm to 12.9 +/- 3.5 mm(3)/mm). In subsegment analysis, significant focal positive vessel remodeling was observed in 5% of ZES and 25% of PES cases (p < 0.05).. There were different global and focal vessel responses for ZES and PES. Both drug-eluting stents showed a similar incidence of lesions with severe narrowing despite ZES having a moderate increase in neointimal hyperplasia compared with neointimal hyperplasia in PES. There was a relatively lower neointima-free frame ratio in ZES, suggesting a greater extent of neointimal coverage. (The ENDEAVOR IV Clinical Trial: A Trial of a Coronary Stent System in Coronary Artery Lesions; NCT00217269). Topics: Aged; Alloys; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coated Materials, Biocompatible; Cobalt; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Hyperplasia; Male; Middle Aged; Paclitaxel; Phosphorylcholine; Prosthesis Design; Single-Blind Method; Sirolimus; Time Factors; Treatment Outcome; Tunica Intima; Ultrasonography, Interventional; United States | 2009 |
Clinical and angiographic outcomes in diabetics from the ENDEAVOR IV trial: randomized comparison of zotarolimus- and paclitaxel-eluting stents in patients with coronary artery disease.
The aim of this study was to examine outcomes related to the use of the Endeavor zotarolimus-eluting stent (ZES) (Medtronic CardioVascular, Santa Rosa, California) compared with the TAXUS paclitaxel-eluting stent (PES) (Boston Scientific Corp., Natick, Massachusetts) in the 477 patients with diabetes mellitus (DM) enrolled in the randomized ENDEAVOR IV (Randomized Comparison of Zotarolimus- and Paclitaxel-Eluting Stents in Patients with Coronary Artery Disease) trial.. Percutaneous coronary intervention (PCI) in diabetic patients is associated with increased rates of restenosis-related end points compared with PCI in nondiabetic patients. Although ZES has been associated with similar clinical efficacy compared with PES in the overall trial population of the ENDEAVOR IV trial, whether these results are maintained in the higher-risk restenosis subgroup of patients with DM has not been determined.. Clinical and angiographic outcomes were compared according to randomized treatment assignment to either ZES or PES.. Baseline characteristics were similar among ZES (n = 241) and PES (n = 236) diabetic patients, with slightly longer lesion lengths in PES-treated patients (12.9 mm vs. 14.0 mm, p = 0.041). Among the 86 DM patients assigned to routine angiographic follow-up (18% of the overall DM cohort), in-stent percent diameter stenosis at 8 months was greater among ZES-treated patients (32.9 vs. 21.1, p = 0.023), with a trend toward higher in-stent late loss. One-year clinical outcomes were similar among DM patients treated with either ZES or PES (target vessel failure: 8.6% vs. 10.8%, p = 0.53; target lesion revascularization: 6.9% vs. 5.8%, p = 0.70; target vessel revascularization: 8.6% vs. 9.4%, p = 0.87). There were no significant interactions between DM status and stent type with respect to the outcomes measured, and the relative efficacy/safety of ZES and PES were similar among insulin- and noninsulin-requiring subgroups.. One-year clinical outcomes were similar among DM patients treated with ZES and PES in the ENDEAVOR IV trial. These findings parallel the overall trial results, which demonstrated similar efficacy and safety of ZES and PES for single de novo coronary lesions. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Diabetic Angiopathies; Drug-Eluting Stents; Female; Humans; Hypoglycemic Agents; Insulin; Kaplan-Meier Estimate; Male; Middle Aged; Paclitaxel; Prospective Studies; Prosthesis Design; Severity of Illness Index; Single-Blind Method; Sirolimus; Time Factors; Treatment Outcome; United States | 2009 |
Clinical and angiographic results with the next-generation resolute stent system: a prospective, multicenter, first-in-human trial.
The RESOLUTE trial examined the safety and efficacy of a next-generation zotarolimus-eluting coronary stent, Resolute (Medtronic CardioVascular Inc., Santa Rosa, California).. Revascularization benefits associated with current drug-eluting stents are often diminished in the presence of complex coronary lesions and in certain patient cohorts. Resolute uses a new proprietary polymer coating that extends the duration of drug delivery to match the longer healing duration often experienced in more complex cases.. The RESOLUTE trial was a prospective, nonrandomized, multicenter study of the Resolute stent in 139 patients with de novo coronary lesions with reference vessel diameters > or =2.5 and < or =3.5 mm and lesion length > or =14 and < or =27 mm. The primary end point was 9-month in-stent late lumen loss by quantitative coronary angiography. Secondary end points included major adverse cardiac events (MACE) at 30 days, 6, 9, and 12 months; acute device, lesion, and procedure success; and 9-month target vessel failure (TVF), target lesion revascularization (TLR), stent thrombosis, neointimal hyperplastic (NIH) volume, and percent NIH volume obstruction.. The 9-month in-stent late lumen loss was 0.22 +/- 0.27 mm. Cumulative MACE were 4.3%, 4.3%, 7.2%, and 8.7% at 30 days, 6, 9, and 12 months, respectively. Acute lesion, procedure, and device success rates were 100.0%, 95.7%, and 99.3%, respectively. At 9 months, TLR was 0.0%, TVF was 6.5%, stent thrombosis was 0.0%, NIH volume was 6.55 +/- 7.83 mm(3), and percent NIH volume obstruction was 3.73 +/- 4.05%.. In this feasibility study, the Resolute stent demonstrated low in-stent late lumen loss, minimal neointimal hyperplastic ingrowth, low TLR, no stent thrombosis, and acceptable TVF and MACE. (The RESOLUTE Clinical Trial; NCT00248079). Topics: Aged; Angioplasty, Balloon, Coronary; Australia; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Feasibility Studies; Female; Humans; Hyperplasia; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; New Zealand; Prospective Studies; Prosthesis Design; Sirolimus; Thrombosis; Time Factors; Treatment Outcome; Ultrasonography, Interventional; United States | 2009 |
Comparison of the efficacy and safety of zotarolimus-, sirolimus-, and paclitaxel-eluting stents in patients with ST-elevation myocardial infarction.
Drug-eluting stents (DESs) are increasingly used for treatment of acute ST-segment elevation myocardial infarction (STEMI), but there are few comparisons of outcomes of various types of DES. We compared the efficacy and safety of zotarolimus-eluting stents (ZESs), sirolimus-eluting stents (SESs), and paclitaxel-eluting stents (PESs) in primary intervention for STEMI. This multicenter, prospectively randomized ZEST-AMI trial included 328 patients at 12 medical centers who were randomly assigned to ZES (n = 108), SES (n = 110), or PES (n = 110) deployment. The primary end point was major adverse cardiac events (death, MI, and ischemia-driven target vessel revascularization) at 12 months. Secondary end points included the individual components of the primary end point, late loss, angiographic restenosis, and stent thrombosis. Baseline clinical and angiographic characteristics were well matched. In-segment late loss (0.28 +/- 0.42 vs 0.46 +/- 0.48 vs 0.47 +/- 0.50 mm, respectively, p = 0.029) and restenosis rate (2.7% vs 15.9% vs 12.3%, respectively, p = 0.027) at 8 months were lowest in the SES group compared to the ZES and PES groups. At 12 months, cumulative incidence rates of primary end points in the ZES, SES, and PES groups were 11.3%, 8.2%, and 8.2%, respectively (p = 0.834). There were 2 acute (in the SES group) and 5 subacute (2 in the SES group and 3 in the PES group) stent thromboses. Incidence of death, recurrent MI, or ischemia-driven target vessel revascularization did not differ among the 3 groups. In conclusion, despite the difference in restenosis rate, the efficacy and safety of the 3 different DESs showed similar, acceptable results in the treatment of STEMI. Topics: Angioplasty, Balloon, Coronary; Aspirin; Cardiovascular Agents; Clopidogrel; Coronary Angiography; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Myocardial Revascularization; Paclitaxel; Platelet Aggregation Inhibitors; Prospective Studies; Recurrence; Sirolimus; Ticlopidine | 2009 |
A randomized, controlled, multicenter trial to evaluate the safety and efficacy of zotarolimus- versus paclitaxel-eluting stents in de novo occlusive lesions in coronary arteries The ZoMaxx I trial.
A novel zotarolimus-eluting coronary stent system (ZoMaxx, Abbott Laboratories, Abbott Park, Illinois) was compared with a paclitaxel-eluting coronary stent (Taxus Express2) in a randomized trial of percutaneous intervention for de novo coronary artery stenosis. The primary end point was defined as noninferiority of in-segment late lumen loss after 9 months.. The ZoMaxx stent system elutes 10 microg/mm zotarolimus using a phosphorylcholine polymer loaded onto a novel stainless steel stent platform containing a 0.0007-inch inner layer of tantalum.. Twenty-nine investigative sites in Europe, Australia, and New Zealand enrolled 401 patients, 396 of whom received a study stent.. After 9 months, late lumen loss was significantly greater in the ZoMaxx group (in-stent 0.67 +/- 0.57 mm vs. 0.45 +/- 0.48 mm; p < 0.001; in-segment 0.43 +/- 0.60 mm vs. 0.25 +/- 0. 45 mm; p = 0.003), resulting in significantly higher rates of >50% angiographic restenosis (in-stent 12.9% vs. 5.7%; p = 0.03; in-segment 16.5% vs. 6.9%; p = 0.007). The upper bound of the 95% confidence interval on the difference in in-segment late lumen loss between the 2 treatment groups (0.27 mm) exceeded the 0.25 mm value pre-specified for noninferiority. There were no significant differences between ZoMaxx and Taxus-treated groups with respect to target lesion revascularization (8.0% vs. 4.1%; p = 0.14), major adverse cardiac events (12.6% vs. 9.6%; p = 0.43), or stent thrombosis (0.5% in both groups).. After 9 months, the ZoMaxx stent showed less neointimal inhibition than the Taxus stent, as shown by higher in-stent late loss and restenosis by qualitative coronary angiography. Topics: Aged; Angioplasty, Balloon, Coronary; Australia; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Europe; Female; Humans; Logistic Models; Male; Middle Aged; New Zealand; Paclitaxel; Prospective Studies; Prosthesis Design; Risk Assessment; Severity of Illness Index; Sirolimus; Thrombosis; Time Factors; Treatment Outcome; Ultrasonography, Interventional | 2008 |
Comparison of vascular response to zotarolimus-eluting stent versus sirolimus-eluting stent: intravascular ultrasound results from ENDEAVOR III.
The purpose of this study was to investigate the vascular response of zotarolimus-eluting stent (ZES) and sirolimus-eluting stent (SES) using serial intravascular ultrasound (IVUS).. Data were obtained from the Endeavor Drug-Eluting Coronary Stent System Versus the Center Siromlimus-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions (ENDEAVOR) III trial, a randomized study comparing ZES and SES for the treatment of de novo native coronary artery lesions. Serial (baseline and 8-month follow-up) IVUS was available in 258 patients (190 ZES, 68 SES).. At 8 months, ZES had greater percentage of neointimal volume index (ZES 1.1 +/- 0.8 mm3/mm vs SES 0.2 +/- 0.1 mm3/mm, P < .01), resulting in smaller lumen volume index (6.0 +/- 2.0 mm3/mm vs 7.0 +/- 2.1 mm3/mm, P < .05). Zotarolimus-eluting stents showed larger IVUS-detectable neointimal coverage over stent surface (50.2% vs 10.5%, P < .01) and greater mean neointimal thickness (0.19 +/- 0.07 mm vs 0.10 +/- 0.06 mm, P < .01). Zotarolimus-eluting stents had a significantly lower incidence of late-acquired incomplete stent apposition.. Zotarolimus-eluting stent is associated with a significantly greater amount of neointimal hyperplasia compared with SES. This amount of hyperplasia in ZES is distributed throughout the stent at 8-month follow-up. Topics: Aged; Angioplasty, Balloon, Coronary; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Probability; Reference Values; Risk Assessment; Sensitivity and Specificity; Single-Blind Method; Sirolimus; Survival Rate; Time Factors; Treatment Outcome; Tunica Intima; Ultrasonography, Interventional; Vascular Patency | 2008 |
Sirolimus, Tacrolimus and Zotarolimus eluting stents to treat bifurcated lesions: a 7-month clinical outcome comparison.
Drug eluting stents (DES) have been shown to reduce restenosis compared with bare metal stents in bifurcated lesions. The aim of this study was to evaluate the long-term clinical outcomes of patients with bifurcated lesions treated by 3 different DES.. Consecutive patients with symptomatic coronary artery disease on one bifurcated lesion with SB>2.25 mm (on visual estimation) undergoing at the Department of Cardiology of the Catholic University of Rome, Italy were screened. Patients treated with Sirolimus-eluting stent (Cypher Select; SES Group), Tacrolimus-eluting stent (Taxus-Libertè; TA Group) and Zotarolimus-eluting stent (Endeavor Driver; ZOT Group) were enrolled in the study. Clinical and angiographic characteristics of all patients were prospectively recorded. Major adverse clinical events (MACE), including death, acute myocardial infarction (MI) or target lesion revascularization (TVR) by either percutaneous coronary intervention (PCI) or coronary surgery were recorded during the follow-up. Incidence of definite or probable stent thrombosis was calculated according to the ARC criteria.. Two hundred and forty-one consecutive patients were enrolled (89 Group CY, 98 Group TA and 54 Group EN). Length of follow-up was 235+/-60 days. Baseline clinical and angiographic characteristic were similar across the groups. The adopted technique for stent implantation was provisional stenting (73.4%), T-stenting technique (7%), crush (7%) and V-stenting (2.6%). The rate of patients finally treated with two stents was similar among groups. The cumulative rate of MACE (9% SES, 12% TA, 11% ZOT: P=0.7) and of TVR (2% SES, 9% TA, 7% ZOT) was similar among groups. No definite stent thrombosis was observed during follow-up, while 1 probable stent thrombosis was observed in TA group.. The clinical outcome of bifurcated lesions using DES and mainly a technique of single stent implantation is good. In the present observational study, clinical adverse events did not differ in patients with bifurcated lesions treated by Cypher, Taxus or Endeavor stent implantation. Topics: Aged; Angioplasty, Balloon, Coronary; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Drug Therapy, Combination; Drug-Eluting Stents; Female; Humans; Immunosuppressive Agents; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Proportional Hazards Models; Prospective Studies; Risk Factors; Rome; Sirolimus; Tacrolimus; Treatment Outcome | 2008 |
Randomized, double-blind, multicenter study of the Endeavor zotarolimus-eluting phosphorylcholine-encapsulated stent for treatment of native coronary artery lesions. Clinical and angiographic results of the ENDEAVOR II Trial.
The use of the Endeavor stent might reduce restenosis and stent thrombosis at 9 months.. Patients (n =1,197) treated for single coronary artery stenosis were enrolled in a prospective, randomized, double-blind study and randomly assigned to receive the Endeavor zotarolimus-eluting phosphorylcholine polymer-coated stent (n= 598) or the same bare metal stent but without the drug or the polymer coating (n=599).. The 2 groups were well matched in baseline characteristics. Diabetes was present in 20.1% of patients; the mean reference vessel diameter was 2.75 mm; and the mean lesion length was 14.2 mm. The primary end point of target vessel failure at 9 months was reduced from 15.1% with the bare metal stent to 7.9% with the Endeavor (P=0.0001), and the rate of major adverse cardiac events was reduced from 14.4% with the bare metal stent to 7.3% with the Endeavor (P=0.0001). Target lesion revascularization was 4.6% with Endeavor compared with 11.8% with the bare metal stent (P=0.0001). The rate of stent thrombosis was 0.5% with the Endeavor, which was not significantly different from 1.2% with the bare metal stent. In 531 patients submitted to angiographic follow-up, late loss was reduced from 1.03+/-0.58 to 0.61+/-0.46 (P<0.001) in stent and from 0.72+/-0.61 to 0.36+/-0.46 (P<0.001) in segment. The rate of in-segment restenosis was reduced from 35% to 13.2% with Endeavor (P<0.0001). There was no excessive edge stenosis, aneurysm formation, or late acquired malposition by intravascular ultrasound imaging. Differences in clinical outcome were maintained at 12 and 24 months (P<0.0001).. Compared with bare metal stents, the Endeavor stent is safe and reduces the rates of clinical and angiographic restenosis at 9, 12, and 24 months. Topics: Aged; Australia; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Double-Blind Method; Drug Delivery Systems; Equipment Design; Europe; Female; Humans; Israel; Male; Middle Aged; New Zealand; Pacific Islands; Phosphorylcholine; Prospective Studies; Sirolimus; Stents; Treatment Outcome | 2007 |
Percutaneous coronary revascularization using a trilayer metal phosphorylcholine-coated zotarolimus-eluting stent.
The ZoMaxx Coronary Stent System elutes the antiproliferative agent zotarolimus via a biocompatible phosphorylcholine polymer loaded onto a novel, thin, stainless steel stent platform containing an 0.0007-inch inner layer of tantalum that enhances fluoroscopic radiopacity. The objective of this single-arm prospective clinical trial was to assess the safety and performance of the ZoMaxx stent for the treatment of coronary artery stenosis. Forty consecutive patients with ischemic coronary occlusive disease due to single de novo obstructive lesions of native coronary arteries were treated with 3 x 18 mm ZoMaxx stents at the Dante Pazzanese de Cardiologie in Saõ Paulo, Brazil, between April and July 2005. Independent core laboratories analyzed quantitative coronary angiography and intravascular ultrasound results immediately after stent implantation, and after 4 months. The lesion, procedure, and device-deployment success rates were all 100% (40 of 40). There were no major adverse cardiac events during the study. Follow-up quantitative coronary angiography at 4 months revealed in-stent and in-segment late lumen losses of 0.20 +/- 0.35 and 0.17 +/- 0.35 mm, respectively. Follow-up intravascular ultrasound at 4 months revealed 6.5 +/- 6.2% neointimal volume obstruction. There were no instances of late acquired stent incomplete apposition or stent thrombosis. In conclusion, the ZoMaxx Coronary Stent can be safely implanted for the treatment of de novo coronary artery stenosis. The inhibition of neointima formation as measured by follow-up angiography and IVUS after 4 months suggests therapeutic potential for the reduction of restenosis. Topics: Aged; Angioplasty, Balloon, Coronary; Blood Vessel Prosthesis Implantation; Cardiovascular Agents; Coronary Angiography; Coronary Circulation; Coronary Restenosis; Coronary Stenosis; Female; Follow-Up Studies; Humans; Male; Middle Aged; Phosphorylcholine; Prospective Studies; Prosthesis Design; Research Design; Sirolimus; Stents; Treatment Outcome; Tunica Intima; Ultrasonography, Interventional | 2007 |
Detailed intravascular ultrasound analysis of Zotarolimus-eluting phosphorylcholine-coated cobalt-chromium alloy stent in de novo coronary lesions (results from the ENDEAVOR II trial).
Zotarolimus-eluting phosphorylcholine-coated cobalt-chromium alloy Driver stents (ZES) demonstrated significant reductions in target lesion revascularization rate with few apparent adverse events compared with bare metal stents (BMS; uncoated Driver stents) in a prospective, multicenter, double-blind, randomized controlled trial in de novo coronary lesions. The aim of this study was to examine detailed vascular responses to ZES compared with BMS using serial intravascular ultrasound analysis. A total of 343 patients (ZES n = 178, BMS n = 165) were enrolled in this formal, prespecified intravascular ultrasound substudy of the Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE Zotarolimus-Eluting Driver Coronary Stent in de Novo Native Coronary Artery Lesions (ENDEAVOR II), a prospective, multicenter, double-blind, randomized controlled trial to compare ZES and BMS in de novo native coronary artery lesions. Quantitative and qualitative intravascular ultrasound analyses were performed postprocedurally and at 8-month follow-up in stented and reference segments. ZES showed significantly less neointima, with a larger lumen than BMS at 8 months (percentage neointimal volume 17.6 +/- 10.1% vs 29.4 +/- 17.2%, p <0.0001; maximum percentage neointimal area 32.9 +/- 13.0% vs 47.6 +/- 18.6%, p <0.0001; minimum luminal area 4.9 +/- 1.6 vs 4.0 +/- 1.7 mm(2), p <0.0001) and no unfavorable edge effect. In the 18-mm single stents, ZES showed evenly inhibited neointima compared with BMS. Neither persistent stent-edge dissection nor late-acquired incomplete stent apposition was observed in either group. In conclusion, ZES showed evenly inhibited neointima with no apparent adverse vascular response in stented and reference segments at 8 months compared with BMS. Topics: Chromium Alloys; Coated Materials, Biocompatible; Cohort Studies; Coronary Artery Disease; Coronary Restenosis; Double-Blind Method; Endosonography; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Phosphorylcholine; Prospective Studies; Sirolimus; Stents; Tunica Intima | 2007 |
The relation between clinical features, angiographic findings, and the target lesion revascularization rate in patients receiving the endeavor zotarolimus-eluting stent for treatment of native coronary artery disease: an analysis of ENDEAVOR I, ENDEAVOR I
The clinical and angiographic factors that predict clinically driven target lesion revascularization (TLR) in patients treated with the zotarolimus-eluting stent (ZES) are not known. Accordingly, the differences between ZES-treated patients who required TLR and ZES-treated patients who did not require TLR were examined in 1,306 patients enrolled in 4 pivotal trials of the Endeavor ZES (Medtronic Vascular, Santa Rosa, CA) for the treatment of symptomatic native coronary artery disease. TLR was performed in 64 patients (4.9%) by 9 months, with most cases (89.1%) occurring after 30 days. ZES-treated patients who required TLR had a greater incidence of 2- or 3-vessel disease (p <0.01), more stents implanted (p = 0.05), and lower device (p = 0.04) and procedure (p <0.01) success rates than ZES-treated patients who did not require TLR. The stents implanted in ZES-treated patients who later required TLR were also longer (p = 0.02) and smaller in diameter (p <0.01). Most angiographic outcomes at 8 months (12 months for ZES-treated patients in ENDEAVOR I) were worse for ZES-treated patients who later required TLR. At 9 months, 10.9% of the ZES-treated patients who required TLR had had myocardial infarctions, compared with 2.2% who did not require TLR (p = 0.001). Multivariate analysis identified older age (odds ratio [OR], 1.03; 95% confidence interval [CI], 1.00-1.06), male sex (OR, 1.79; 95% CI, 0.88-3.65), and longer lesion length (OR, 1.03; 95% CI, 0.99-1.07) as risk factors for TLR after ZES implantation (with a C statistic of 0.61, suggesting a modest discriminatory value). These data provide insight into the clinical and angiographic factors that predict TLR at 9 months in ZES-treated patients, making possible the focused surveillance of selected ZES-treated patients who might be at greater risk of TLR. Topics: Anti-Bacterial Agents; Coronary Angiography; Coronary Disease; Coronary Restenosis; Drug Delivery Systems; Drug-Eluting Stents; Female; Humans; Logistic Models; Male; Middle Aged; Myocardial Infarction; Myocardial Revascularization; Registries; Sirolimus | 2007 |
84 other study(ies) available for zotarolimus and Coronary-Restenosis
Article | Year |
---|---|
In Vivo Assessment of In-Stent Restenosis After Resolute Zotarolimus-Eluting Stent Implantation: Multimodality Imaging with Directional Coronary Atherectomy.
Topics: Atherectomy, Coronary; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Humans; Percutaneous Coronary Intervention; Prosthesis Design; Sirolimus; Treatment Outcome | 2023 |
Comparison of 3-year clinical outcomes between Endeavor Resolute® and Resolute Integrity® zotarolimus-eluting stents in an Asian population.
There is a scarcity of comparative studies between Endeavor Resolute®-zotarolimus-eluting stent (R-ZES) and Resolute Integrity®-ZES (I-ZES) during long-term follow-up periods. Although the stent alloy and the polymer of these two ZESs are similar, the platform and the design of these two stents are different. This study was conducted to compare the efficacy and safety of these two different ZESs in the all-comer Korean patients who underwent percutaneous coronary intervention (PCI) during a 3-year follow-up period.. This study was performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki. In this single-center, retrospective, and all-comer patients' cohort study, a total of 889 patients who underwent PCI with R-ZES (n=394) or I-ZES (n=495) were enrolled. The primary endpoint was the occurrence of major adverse cardiac events (MACEs) defined as all-cause death, nonfatal myocardial infarction (MI), any repeat revascularization including target lesion revascularization (TLR), target vessel revascularization (TVR), and non-TVR, and the secondary endpoint was stent thrombosis (ST) at 3 years.. To adjust for any potential confounders, the propensity score-adjusted multivariable analysis was performed using the logistic regression model (C-statistics=0.689). The cumulative incidence rates of MACEs [adjusted hazard ratio (aHR), 1.341; 95% confidence interval (CI), 0.615-2.922; p=0.461], all-cause death, nonfatal MI, any repeat revascularization, and ST (aHR, 2.090; 95% CI, 0.163-26.77; p=0.571) were similar between the two groups during the 3-year follow-up period.. R-ZES and I-ZES demonstrated comparable efficacy and safety after PCI during a 3-year follow-up period. However, these results can perhaps be more precisely defined by other large and long-term follow-up studies in the future. (Anatol J Cardiol 2020; 23: 268-76). Topics: Asian People; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Republic of Korea; Retrospective Studies; Risk Factors; Sirolimus | 2020 |
Ten-year outcomes from a randomised comparison of zotarolimus-eluting and sirolimus-eluting stents: the SORT OUT III study.
Topics: Angioplasty, Balloon, Coronary; Coronary Disease; Coronary Restenosis; Drug-Eluting Stents; Follow-Up Studies; Humans; Myocardial Infarction; Percutaneous Coronary Intervention; Randomized Controlled Trials as Topic; Sirolimus; Thrombosis; Treatment Outcome | 2019 |
Clinical outcomes of complex real-world diabetic patients treated with amphilimus sirolimus-eluting stents or zotarolimus-eluting stents: A single-center registry.
To assess clinical outcomes of Amphilimus Sirolimus-Eluting Stents (A-SES) as compared to Zotarolimus-Eluting Stents (ZES) in complex real-world diabetic patients.. Patients with diabetes mellitus represent one of the most challenging scenarios with high rates of restenosis and stent thrombosis in the current era of drug-eluting stents. Hence, we assessed the safety of A-SES versus ZES in complex diabetic patients.. In this observational study, we analyzed all consecutive patients with diabetes mellitus referred to our center from November 2012 to November 2014. The primary outcome was target-lesion failure at 1-year follow-up.. A total of 165 consecutive diabetic patients underwent percutaneous coronary intervention with A-SES or ZES for stable coronary artery disease in our tertiary center. Using the Kaplan Meier method the cumulative incidence of target-lesion failure was 6.7% (5.9% A-SES versus 7.5% ZES, p=0.19) at 1-year follow-up. Event-free survival at 1year follow-up was similar (89.4% A-SES vs. 83.3% ZES, p=0.29). Interestingly, we did not find any cases of definite-, and only one case of probable stent thrombosis in this high risk cohort.. In this real-world registry, A-SES and ZES seems to be associated with promising 1-year clinical safety outcomes following PCI in a contemporary cohort of high-risk diabetic patients. Our results should be considered hypothesis generating, as the clinical safety of A-SES has to be confirmed in a large trial. Topics: Aged; Aged, 80 and over; Cardiovascular Agents; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Diabetes Mellitus; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Netherlands; Percutaneous Coronary Intervention; Progression-Free Survival; Prosthesis Design; Registries; Retrospective Studies; Risk Factors; Sirolimus; Time Factors | 2018 |
Angiographic and clinical outcomes after recanalization of coronary chronic total occlusions with the Orsiro sirolimus-eluting stent compared with the resolute zotarolimus-eluting stent.
The third generation drug eluting Orsiro stent had shown already promising results in non-complex lesions.. We evaluated angiographic and 24 month clinical results of the sirolimus eluting Orsiro stents (O-SES) after recanalization of coronary chronic total occlusions (CTO). Results were compared with the zotarolimus eluting Resolute Integrity (R-ZES).. In a prospective series 57 patients were treated with a R-ZES followed by 74 patients treated with a O-SES stent. Angiographic follow up after 9 months and clinical follow-up after 12 and 24 months was performed.. In-stent late lumen loss was 0.24±0.53 mm for the O-SES compared with 0.59±0.72 (P=0.01) for R-ZES. Rates for TLR were similar (O-SES 10.0% versus R-ZES 11.1%, P=0.84). There was no definite stent thrombosis.. The O-SES resulted in a significant lower late lumen loss but with similar clinical results up to 24 month compared to the R-ZES after treatment of CTO lesions. Topics: Aged; Cardiovascular Agents; Chronic Disease; Coronary Angiography; Coronary Occlusion; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2017 |
Impact of stent implantation on endothelial shear stress.
Endothelial shear stress (ESS) may play a key role in the pathobiology of stent restenosis (SR). Nevertheless, limited data are available about ESS and its relation to SR.. We enrolled 14 patients who underwent successful percutaneous coronary intervention (PCI) in this study. Three-dimensional (3D) reconstruction of 14 coronary arteries before and after stent implantation was performed. Using computational fluid dynamics, mean ESS was calculated proximally, in tertiles within and distal to the stent, both before and after stent implantation.. Stent implantation resulted in a significant ESS decrease in the entire atherosclerotic lesion (1.83 vs. 1.26 Pa, p = 0.02). Regarding the five territories in which the entire lesion was divided, ESS decrease was marginally significant in the area of the second in-stent tertile, and in the area 5 mm distal to the stent, whereas ESS decrease was not significant in the area 5 mm proximal to the stent, and in the area of the first and third in-stent tertile. At 12 months, two patients had SR, but restenosis was not related to ESS decrease.. ESS decreases after stent implantation but not uniformly, with the major reduction being in the middle tertile of the stent, and distal to the stent. In-stent ESS decrease may create local hemodynamic conditions leading to in-stent and in-segment restenosis. Topics: Algorithms; Computed Tomography Angiography; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Elastic Tissue; Endothelium, Vascular; Follow-Up Studies; Hemodynamics; Humans; Hydrodynamics; Image Interpretation, Computer-Assisted; Imaging, Three-Dimensional; Patient-Specific Modeling; Percutaneous Coronary Intervention; Shear Strength; Sirolimus | 2017 |
Comparison of clinical outcomes after multivessel versus single-vessel stenting with the zotarolimus-eluting stent in the RESOLUTE Global Clinical Trial Program.
Our aim was to investigate whether long-term (three-year) clinical outcomes after multivessel treatment with the Resolute zotarolimus-eluting stent (R-ZES) were similar to single-vessel treatment.. The RESOLUTE Global Clinical Trial Program enrolled 7,618 patients, of whom 1,562 underwent multivessel and 6,053 single-vessel treatment with the R-ZES. Patients in the multivessel group were more likely to have complex lesions (58% vs. 44%, p<0.001). Clinical outcomes were compared using a Cox regression model adjusted by propensity score to account for differences in baseline characteristics. Compared with single-vessel treatment, multivessel treatment was associated with more complex anatomy and longer mean total stent length (57.8±28.6 vs. 26.7±15.2 mm, p<0.001). At three years, the cumulative incidence of target lesion failure was similar in patients with multivessel and single-vessel treatment (11.0% vs. 9.1%, adjusted p=0.986), as was the incidence of cardiac death or target vessel myocardial infarction (6.7% vs. 5.7%, adjusted p=0.793), the incidence of clinically driven target lesion revascularisation (5.1% vs. 4.4%, adjusted p=0.904), and the incidence of Academic Research Consortium definite or probable stent thrombosis (1.2% vs. 0.9%, adjusted p=0.544).. Multivessel treatment with R-ZES provided good long-term clinical outcomes that were comparable to those achieved with single-vessel stenting, supporting the efficacy and safety of R-ZES in patients in this setting. Topics: Adult; Aged; Aged, 80 and over; Clinical Trials as Topic; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2017 |
Comparison of the performance of zotarolimus- and everolimus-eluting stents by optical coherence tomography and coronary angioscopy.
Overall stent performance should be characterized by geometric luminal gain acquisition, neointimal coverage of the stent struts, and stabilization of the underlying inflammatory neoatheroma. The aim of this study was to compare the performance of zotarolimus-eluting stent (ZES), everolimus-eluting stent (EES) and bare metal stent (BMS) using optical coherence tomography (OCT) and coronary angioscopy. For 36 stented coronary lesions (BMS, 12 lesions; ZES, 11 lesions; EES, 13 lesions) in 27 patients, we calculated neointimal area and uncovered stent strut rate based on OCT findings at 10 months after stent placement. The grades of neointimal coverage and yellow color, both of which were classified from 0 to 3, were also assessed by coronary angioscopy. The plaque area of the ZES lesions was larger than that of the EES lesions (P < 0.05) but smaller than that of the BMS lesions (P < 0.05). The OCT-based uncovered rate of the ZES lesions was less than that of the EES lesions (P < 0.01), but similar to that of the BMS lesions. The stent coverage grade by angioscopy was higher in the ZES lesions than in the EES lesions (P < 0.05), but similar to the BMS lesions. The yellow grade was less in the ZES lesions than in the EES lesions (P < 0.01), but similar to the BMS lesions. ZES might be better than BMS in terms of neointimal thickening, and better than EES in terms of neointimal coverage as well as prevention of neoatheroma formation. ZES may have superior performance compared with EES. Topics: Aged; Angioscopy; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Neointima; Sirolimus; Tomography, Optical Coherence | 2016 |
Comparison of Long-Term Outcomes in Real-World Patients Between Resolute Zotarilumus-Eluting and Paclitaxel-Eluting Stents in Small Vessel.
To compare the long-term clinical outcomes between Resolute zotarolimus-eluting stent (R-ZES) and paclitaxel-eluting stent (PES) in patients with small coronary artery disease.. Patients with a small vessel diameter are independently associated with increased risk of adverse cardiac events after drug-eluting stent implantation.. A cohort of 265 patients treated with R-ZES (185 patients with 211 lesions) or PES (80 patients with 100 lesions) in small vessel (≤2.5 mm) lesions were retrospectively analyzed. The primary end point of the study was the composite of major adverse cardiac events. The secondary end points included target lesion revascularization (TLR), target vessel revascularization (TVR), and stent thrombosis at 3 years.. The baseline characteristics were similar between the 2 groups. In the R-ZES group, the mean stent diameter was smaller and the total stent length per lesion was longer. Major adverse cardiac events occurred in 8 (10%) patients who had received PES and in 7 (3.8%) patients who had received R-ZES (P = .07). The rates of 3-year TLR (2.2% vs 2.5%; P = 1.00) and TVR (5.4% vs 10.0%; P = .17) showed no statistically significant difference between the R-ZES and PES groups. The rate of stent thrombosis was 0.5% in the R-ZES group and 2.5% in the PES group (P = .21).. The rates of major adverse cardiac events and cardiac death were similar in the R-ZES-treated group compared with the PES-treated group. Topics: Adult; Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Paclitaxel; Percutaneous Coronary Intervention; Retrospective Studies; Risk Factors; Sirolimus; Treatment Outcome | 2016 |
Zotarolimus compared with everolimus eluting stents-angiographic and clinical results after recanalization of true coronary chronic total occlusions.
To evaluate angiographic and clinical results of ZES compared with EES after recanalization of CTOs.. ZES and EES showed similar clinical results in non-CTO lesions. Whether ZES and EES are also comparable in true CTO lesions (TIMI 0 flow, duration of occlusion of more than 3 months) with a higher risk of restenosis has not been addressed so far.. 125 patients with successful CTO recanalization via antegrade or retrograde approach were included. EES were implanted in 68 patients and ZES in 57 patients. Dual antiplatelet therapy was prescribed for 12 months. Follow-up angiography was scheduled at 9 months and clinical follow-up at 12 months. The primary angiographic outcome measure was in-stent late lumen loss. Primary clinical outcome measures were target lesion revascularization rate (TLR) and major adverse cardiac events (MACE) as a composite of cardiac death, TLR and myocardial infarction not clearly attributable to a non-target vessel.. Baseline characteristics were similar in both groups. Mean stent length was 72.8 ± 33.0mm with EES and 70.8 ± 31.5 mm with ZES (P = 0.72). In-stent late lumen loss was 0.50 ± 0.71 mm for EES compared with 0.59 ± 0.72 (P = 0.52) for ZES. There were similar rates for TLR (EES 10.3% versus ZES 10.5%, P = 0.97) and MACE (EES 10.3% versus ZES 12.3%). No definite or probable stent thrombosis occurred. Stent length but not type of stent was predictive for in-stent late loss and TLR.. ZES and EES showed similar angiographic and clinical outcomes for treatment of CTOs. © 2016 Wiley Periodicals, Inc. Topics: Aged; Cardiovascular Agents; Chronic Disease; Coronary Angiography; Coronary Occlusion; Coronary Restenosis; Drug Therapy, Combination; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Predictive Value of Tests; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2016 |
Effects of Low Endothelial Shear Stress After Stent Implantation on Subsequent Neointimal Hyperplasia and Clinical Outcomes in Humans.
In-stent hyperplasia (ISH) may develop in regions of low endothelial shear stress (ESS), but the relationship between the magnitude of low ESS, the extent of ISH, and subsequent clinical events has not been investigated.. We assessed the association of poststent ESS with neointimal ISH and clinical outcomes in patients treated with percutaneous coronary interventions (PCI). Three-dimensional coronary reconstruction was performed in 374 post-PCI patients at baseline and 6 to 10 months follow-up as part of the PREDICTION Study. Each vessel was divided into 1.5-mm-long segments, and we calculated the local ESS within each stented segment at baseline. At follow-up, we assessed ISH and the occurrence of a clinically indicated repeat PCI for in-stent restenosis. In 246 total stents (54 overlapping), 100 (40.7%) were bare-metal stents (BMS), 104 (42.3%) sirolimus-eluting stents, and 42 (17.1%) paclitaxel-eluting stents. In BMS, low ESS post-PCI at baseline was independently associated with ISH (β=1.47 mm(2) per 1-Pa decrease; 95% CI, 0.38-2.56; P<0.01). ISH was minimal in drug-eluting stents. During follow-up, repeat PCI in BMS was performed in 21 stents (8.5%). There was no significant association between post-PCI ESS and in-stent restenosis requiring PCI.. Low ESS after BMS implantation is associated with subsequent ISH. ISH is strongly inhibited by drug-eluting stents. Post-PCI ESS is not associated with in-stent restenosis requiring repeat PCI. ESS is an important determinant of ISH in BMS, but ISH of large magnitude to require PCI for in-stent restenosis is likely attributed to factors other than ESS within the stent. Topics: Aged; Coronary Restenosis; Drug-Eluting Stents; Early Diagnosis; Female; Follow-Up Studies; Hemodynamics; Humans; Hyperplasia; Immunosuppressive Agents; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Sirolimus; Stents; Stress, Mechanical; Treatment Outcome | 2016 |
Prospective randomized comparison of clinical and angiographic outcomes between everolimus-eluting vs. zotarolimus-eluting stents for treatment of coronary restenosis in drug-eluting stents: intravascular ultrasound volumetric analysis (RESTENT-ISR trial)
At present no proven standard treatment for drug-eluting stent (DES) restenosis is available, and the efficacy and safety of everolimus-eluting stent (EES) and zotarolimus-eluting stent (ZES) for DES restenosis are limited. The purpose of this prospective, randomized 9-month intracoronary ultrasound (IVUS) and 3-year clinical follow-up study was to compare the effects of EESs and ZESs on neointima volume and major adverse cardiovascular events (MACEs) such as death, myocardial infarction (MI), target lesion revascularization (TLR) and stent thrombosis in DES restenosis patients.. Patients with first- and second-generation DES restenosis, both EES and ZES implantation were effective and safe in reducing neointima volume and late loss with a comparable rate of MACEs independent of cardiovascular risk factors. Topics: Coronary Restenosis; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Male; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Treatment Outcome | 2016 |
Outcomes of stenting extra-small (≤2.25 mm) vessels using the Resolute zotarolimus-eluting stent (R-ZES).
We assessed long-term outcomes in patients with extra-small (XS) (≤2.25 mm) and small vessels (SV) (>2.25-2.75 mm) treated with the Resolute zotarolimus-eluting stent (R-ZES).. Data from eight studies including patients with XS or SV were pooled for this analysis. Among 2,141 patients (837 XS, 1,304 SV), three-year cumulative major adverse cardiac events (15.4% vs. 11.5%; adj. HR [95% CI]: 1.3 [1.0, 1.7], p=0.12), target lesion failure (12.4% vs. 9.3%, adj. HR: 1.1 [0.8, 1.5], p=0.56), and target lesion revascularisation (TLR: 6.9% vs. 4.5%, adj. HR 1.4 [0.9, 2.1], p=0.17) were greater in the XS cohort but were not significantly different after propensity adjustment. Target vessel revascularisation occurred more frequently in XS patients in both unadjusted and adjusted analyses (11.2% vs. 7.6%, adj. HR: 1.5 [1.1, 2.1], p=0.02). Stent thrombosis was low in both cohorts (1.2% vs. 0.6%, p=0.09). In the XS cohort, insulin-dependent diabetics had over twofold higher rates of TLR than non-diabetics (13.6% vs. 6.0%, p=0.02).. Long-term lesion-specific results among patients with XS vessels treated with the R-ZES were not significantly different from those among patients with SV, but specific patients with XS vessels (e.g., insulin-dependent diabetics) may remain at high risk for TLR. Topics: Adult; Aged; Aged, 80 and over; Cardiovascular Agents; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Sirolimus; Treatment Outcome | 2016 |
Clinical and angiographic evaluation of the resolute zotarolimus-eluting coronary stent in Japanese patients – long-term outcome in the RESOLUTE Japan and RESOLUTE Japan small vessel study.
This study evaluated the safety and efficacy of the RESOLUTE(TM)zotarolimus-eluting stent (R-ZES; Medtronic, Inc, Santa Rosa, CA, USA) in Japanese patients for the treatment of de novo native coronary lesions.. Both RESOLUTE Japan (R-Japan) and RESOLUTE Japan Small Vessel Study (R-Japan SVS) were prospective, multicenter, single-arm observational studies. R-Japan enrolled 100 patients (reference vessel diameter, 2.5-3.5 mm) and R-Japan SVS enrolled 65 patients (at least 1 lesion suitable for 2.25-mm stent) treated with R-ZES. In R-Japan, in-stent late lumen loss (LLL; the primary endpoint) at 8 months was 0.12 ± 0.22 mm and volume obstruction on intravascular ultrasound was 2.33 ± 3.51%. At 4 years, there were no cases of clinically driven target lesion revascularization (TLR); the target lesion failure (TLF; composite of cardiac death, target vessel myocardial infarction, and clinically driven TLR) was 5.6% (5/90). In R-Japan SVS, in-stent LLL at 9 months was 0.27 ± 0.33 mm, TLF (primary endpoint) was 4.6% (3/65), without incidence of TLR. At 3 years, TLF was 7.9% (5/63) and clinically driven TLR, 3.2% (2/63).. R-Japan and R-Japan SVS demonstrate substantial suppression of neointimal hyperplasia, low LLL, and excellent and sustained long-term clinical outcome with R-ZES in Japanese patients. Topics: Combined Modality Therapy; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Heart Diseases; Humans; Incidence; Japan; Myocardial Infarction; Myocardial Revascularization; Neointima; Platelet Aggregation Inhibitors; Postoperative Complications; Prospective Studies; Risk Factors; Sirolimus; Treatment Outcome; Ultrasonography, Interventional | 2015 |
Angiographic patterns of restenosis with 2nd generation drug-eluting stent: comparative analysis from a 10-year single-center experience .
The angiographic features of restenosis contain prognostic information. However, restenosis patterns of the new generation drug-eluting stents (DES), everolimus-(EES) and resolute zotarolimus-eluting stent (ZES) have not been described.A total of 210 consecutive patients with DES restenosis were enrolled from 2003 to 2012. We analyzed 217 restenotic lesions after DES implantation, and compared the morphologic characteristics of the 2nd generation DES restenosis to those of restenosis with 2 first generation DES, sirolimus-(SES) and paclitaxel-eluting stent (PES).Baseline characteristics were comparable between the different stent groups. The incidence of focal restenosis was significantly lower for PES than the other stents (49.5% versus 87.0%, 76.2%, and 82.1% for PES versus SES, EES, and ZES, respectively, P < 0.001). When considering the pattern of restenosis solely within the stent margins, a further clear distinction between PES and other stents was observed (40.0% versus 92.9%, 88.9%, and 81.2% in PES versus SES, EES, and ZES, respectively, P < 0.001). There were no significant differences in restenosis patterns among SES, EES, and ZES. In multivariate analysis, PES implantation, hypertension, and age were associated with non-focal type of restenosis after DES implantation. After the introduction of EES and ZES into routine clinical practice in 2008, focal restenosis significantly increased from 63.9% to 76.7% and diffuse restenosis significantly decreased from 26.4% to 11.0% (P = 0.045).Focal restenosis was the most common pattern of restenosis in the new generation DES and the incidence of diffuse restenosis significantly decreased with the introduction of the 2nd generation DES. Topics: Aged; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Incidence; Male; Middle Aged; Paclitaxel; Percutaneous Coronary Intervention; Postoperative Complications; Registries; Republic of Korea; Sirolimus; Treatment Outcome; Vascular Patency | 2015 |
Stent selection and antiplatelet therapy duration: one size does not fit all.
Topics: Clopidogrel; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Hemorrhage; Humans; Male; Percutaneous Coronary Intervention; Postoperative Complications; Sirolimus; Ticlopidine | 2015 |
Cyphering the mechanism of late failure of bioresorbable vascular scaffolds in percutaneous coronary intervention of the left main coronary artery.
Topics: Absorbable Implants; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Female; Humans; Middle Aged; Neointima; Percutaneous Coronary Intervention; Prosthesis Design; Prosthesis Failure; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2015 |
Comparison of 2-year outcomes of repeated second-generation drug-eluting stent implantation for focal-type versus nonfocal-type in-stent restenosis.
Second-generation drug-eluting stents (DES) have been used widely to treat DES in-stent restenosis (ISR), which remains a clinical challenge. Knowledge of the outcomes of repeated second-generation DES implantation for focal versus nonfocal-type ISR is still missing.. In the current study, 254 patients with DES-ISR were divided into focal or nonfocal groups according to their ISR angiographic types. All patients with ISR lesions included in the current study received second-generation DES. Treatment modalities for both groups were similar without any systematic bias toward either group. The primary endpoint of the study was the occurrence of major adverse cardiac events (MACEs) over a 2-year follow-up period. MACEs were defined as cardiac death, myocardial infarction, and target lesion revascularization.. The nonfocal-type group showed significantly greater incidence of MACEs than the focal-type group (38.3 vs. 24.1%; P=0.03), in which the occurrence of target lesion revascularization was more pronounced (32.3 vs. 18.4%; P=0.02). However, this group showed a higher incidence of type B2/C lesions (69.5 vs. 41.4%; P<0.01), with longer lesion length, and received significantly more and longer reimplanted stents than the focal-type group. Cox regression analysis indicated that nonfocal-type ISR was an independent predictor of MACEs (odds ratio 2.134, 95% confidence interval 1.173-3.884; P=0.014) after adjusting for all significant variables.. In the current study, second-generation DES is more effective in the treatment of focal-type DES-ISR than nonfocal-type ISR in terms of the occurrence of MACEs. Nonfocal-type ISR is an independent predictor of MACEs after the treatment of DES-ISR with second-generation DES. Topics: Aged; Antineoplastic Agents; Cardiovascular Diseases; Coronary Angiography; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Middle Aged; Myocardial Infarction; Myocardial Revascularization; Percutaneous Coronary Intervention; Proportional Hazards Models; Retreatment; Retrospective Studies; Sirolimus; Treatment Outcome | 2015 |
Mechanisms and Patterns of Intravascular Ultrasound In-Stent Restenosis Among Bare Metal Stents and First- and Second-Generation Drug-Eluting Stents.
The most common causes of in-stent restenosis (ISR) are intimal hyperplasia and stent under expansion. The purpose of this study was to use intravascular ultrasound (IVUS) to compare the ISR mechanisms of bare metal stents (BMS), first-generation drug-eluting stents (DES), and second-generation DES. There were 298 ISR lesions including 52 BMS, 73 sirolimus-eluting stents, 52 paclitaxel-eluting stents, 16 zotarolimus-eluting stents, and 105 everolimus-eluting stent. Mean patient age was 66.6 ± 1.1 years, 74.2% were men, and 48.3% had diabetes mellitus. BMS restenosis presented later (70.0 ± 66.7 months) with more intimal hyperplasia compared with DES (BMS 58.6 ± 15.5%, first-generation DES 52.6 ± 20.9%, second-generation DES 48.2 ± 22.2%, p = 0.02). Although reference lumen areas were similar in BMS and first- and second-generation DES, restenotic DES were longer (BMS 21.8 ± 13.5 mm, first-generation DES 29.4 ± 16.1 mm, second-generation DES 32.1 ± 18.7 mm, p = 0.003), and stent areas were smaller (BMS 7.2 ± 2.4 mm(2), first-generation DES 6.1 ± 2.1 mm(2), second-generation DES 5.7 ± 2.0 mm(2), p <0.001). Stent fracture was seen only in DES (first-generation DES 7 [5.0%], second-generation DES 8 [7.4%], p = 0.13). In conclusion, restenotic first- and second-generation DES were characterized by less neointimal hyperplasia, smaller stent areas, longer stent lengths, and more stent fractures than restenotic BMS. Topics: Aged; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Male; Metals; Middle Aged; Neointima; Paclitaxel; Percutaneous Coronary Intervention; Prosthesis Design; Retrospective Studies; Risk Factors; Sirolimus; Stents; Time Factors; Treatment Outcome; Ultrasonography, Interventional | 2015 |
Zotarolimus-eluting stent utilization in small-vessel coronary artery disease (ZEUS).
The role of the second-generation zotarolimus-eluting stent RESOLUTE in small-vessel coronary artery disease is unclear. The aim of this study was examine the angiographic results of RESOLUTE in de novo coronary lesions of ≥50 % diameter stenosis in target vessels ≤2.5 mm. From August 2008 to April 2010, 142 symptomatic patients with 159 lesions who fitted the inclusion criteria were treated with RESOLUTE. The mean age of patients was 66 ± 10 years, with male predominance (66 %). Diabetes mellitus was found in 62 (43.7 %) patients, whereas multivessel disease was observed in 105 (73.9 %). The mean stent size and length used were 2.33 ± 0.13 and 22 ± 8 mm, respectively. Follow-up angiography was performed on 143 (89.9 %) lesions in 127 (89.4 %) patients at a mean of 10.3 ± 3.6 months. Angiographic restenosis was found in 9 (6.3 %) lesions; the late loss was 0.26 ± 0.34 mm. At 1-year follow-up there were four cardiovascular deaths, two nonfatal myocardial infarctions, and six repeated revascularizations. The resultant major adverse cardiac event rate was 8.5 %. The use of RESOLUTE to treat small-vessel disease is associated with good clinical and angiographic outcomes at 1 year. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prosthesis Design; Retrospective Studies; Sirolimus; Time Factors; Treatment Outcome | 2014 |
Integrity of stent polymer layer after drug-eluting stent implantation: in vivo comparison of sirolimus-, paclitaxel-, zotarolimus- and everolimus-eluting stents.
Few data exist with regard to the polymer integrity of drug-eluting stents (DES) in vivo. This study aims to investigate the integrity of the polymer layer of 4 polymer-coated DES in vivo. We assessed the morphology of the polymer layer of sirolimus-eluting stent (SES; Cypher Select™), paclitaxel-eluting stent (PES; Taxus Liberté™), zotarolimus-eluting stent (ZES; Endeavour RX™) and everolimus-eluting stent (EES; Xience V™) by scanning electron microscopy after balloon expansion at nominal and high pressures in the coronary arteries of 3 pigs. Effects of kissing balloon procedure were also explored. The polymer layer of SES, PES and EES were damaged in less than 3 % of the surface area with high pressure procedures, whereas the damaged area reached 38.0 ± 2.6 % in ZES (P < 0.01). The polymer integrity differed greatly among DES after balloon inflation in vivo. This should be taken into account when placing DES in tortuous vessels, calcified, as well as bifurcation lesions because the polymer layer may be easily damaged in these lesions. Topics: Animals; Antineoplastic Agents, Phytogenic; Blood Vessel Prosthesis Implantation; Coated Materials, Biocompatible; Coronary Restenosis; Disease Models, Animal; Drug-Eluting Stents; Everolimus; Immunosuppressive Agents; Paclitaxel; Prosthesis Design; Sirolimus; Swine | 2014 |
Second-generation versus first-generation drug-eluting stents for the treatment of patients with acute coronary syndromes and obstructive coronary artery disease.
Randomized trials and registries have shown that drug-eluting stents (DES) have an overall better performance than bare-metal stents in patients treated in the setting of both ST-segment and non-ST-segment elevation acute coronary syndromes, mainly by reducing restenosis. Whether or not the use of newer second-generation devices (vs. first-generation DES) differs in these high-risk patients remains to be determined.. In a single-centre prospective registry, 3266 patients underwent a percutaneous coronary intervention with at least one DES from January 2003 to December 2009. Of these, 1423 (43.6%) were treated in the setting of an acute coronary syndrome, using either first-generation-only DES [paclitaxel or sirolimus; n=923 (64.9%)] or second-generation-only [zotarolimus or everolimus; n=500 (35.1%)]. The occurrence of death from any cause, nonfatal myocardial infarction or target vessel failure (composite primary endpoint) was compared between these two groups; repeat revascularization of the index stented lesion and definite stent thrombosis [according to the academic research consortium (ARC) definition] were assessed as isolated secondary outcomes. At a median follow-up of 598 days (interquartile range 453-1206), the incidence of death was 10.7% (152), 136 patients (9.6%) had a new myocardial infarction and target vessel failure events occurred in 147 patients (10.3%). Disparity in the follow-up duration was accounted for by considering only the 1-year major adverse cardiac event rate (n=161; 11.3%). After adjustment for baseline characteristics using a Cox proportional hazard model, we could not find a significant difference in the incidence of the composite primary endpoint at 1-year between first-generation (10.8%) and second-generation DES (12.2%) [hazard ratio (HR): 1.1; 95% confidence interval (CI): 0.82-1.57, P=0.463], nor in the occurrence of repeat target lesion revascularization (3.6 vs. 4.4%; HR 1.35; 95% CI 0.77-2.34; P=0.293). In a per patient analysis, at 1 year, ARC-definite ST was documented in 1.0% of patients treated with second-generation DES versus 2.8% in those treated with first-generation DES (corrected HR 0.36; 95% CI 0.14-0.94; P=0.037), owing mostly to a higher difference in late ST.. Our results suggest that both first-generation and second-generation DES seem to be similarly effective in patients undergoing a percutaneous coronary intervention in the setting of acute coronary syndromes. However, newer second-generation devices may offer potential advantages because of a significantly lower incidence of ARC-definite ST. Topics: Aged; Comparative Effectiveness Research; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Everolimus; Female; Humans; Immunosuppressive Agents; Incidence; Male; Middle Aged; Paclitaxel; Percutaneous Coronary Intervention; Portugal; Proportional Hazards Models; Registries; Sirolimus; Stents; Treatment Outcome | 2014 |
Paclitaxel-coated balloon for the treatment of drug-eluting stent restenosis: subanalysis results from the Valentines I trial.
To analyze the effect of paclitaxel-coated balloon (PCB) treatment on patients with drug-eluting stent (DES) restenosis.. In the Valentines I trial, treatment of coronary in-stent restenosis was effective and safe with the second-generation DIOR® PCB.. Valentines I prospectively enrolled 250 patients with in-stent restenosis (ISR); 76 patients (30.4%) had restenosis of a previous paclitaxel or limus DES. Patients underwent balloon angioplasty followed by PCB treatment. Clinical outcomes of patients with paclitaxel-eluting DES restenosis (n=34; 41 lesions) and limus-eluting (sirolimus, everolimus and zotarolimus) DES restenosis (n=42; 43 lesions) treated with DIOR® PCB were compared.. Baseline characteristics were similar. There were more diffuse lesions >20mm treated in paclitaxel- compared to limus-eluting DES restenosis (50% vs. 26.8%, p=0.032). Number of PCB used per patient (1.08±0.31 overall), mean PCB diameter (2.99±0.42mm overall), mean PCB length (24.4±11.9mm overall), and bailout stenting (2.4% vs. 4.7%) were similar (p=NS). At mean follow-up of 231±43days, major adverse cardiac events was 0% vs. 23.8% in paclitaxel- vs. limus-eluting DES restenosis (p=0.002), driven mainly by less target vessel revascularization (0% vs. 21.4%, p=0.004). Target lesion revascularization was 0% vs. 16.7% for paclitaxel- vs. limus-eluting DES restenosis (p=0.015).. In Valentines I, PCB use was more effective in patients with paclitaxel DES restenosis compared to limus DES restenosis, achieving better mid-term clinical outcomes. This suggests the efficacy of localized paclitaxel delivery to overcome paclitaxel resistance but not limus resistance due to different mechanisms of DES failure. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Paclitaxel; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Registries; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2014 |
Is "the bigger the better" still valid for drug-eluting stents?
Topics: Cardiovascular Agents; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Everolimus; Female; Humans; Male; Percutaneous Coronary Intervention; Sirolimus; Ultrasonography, Interventional | 2014 |
Long-term comparative analysis from an all-comer cohort of coronary patients treated using first- and second-generation drug-eluting stents.
Second-generation drug eluting stent (DES) implantation gradually replaced the first-generation DES in clinical practice. Whether the new DESs in use differ from one another, in terms of clinical outcomes, is still not known. We explored potential differences among DESs.. We followed 9584 consecutive patients undergoing percutaneous coronary intervention at our institution (2004-2012; mean follow-up, 2.8 years). Patients treated with bare-metal stent (BMS; n = 5599; 58.4%) were compared to 3985 DES counterparts (41.5%). The sirolimus-eluting stent (SES) served as the prototype for comparison to other DES types, using propensity matching. The primary outcome was a composite endpoint of total mortality, myocardial infarction, and clinically driven target vessel revascularization or coronary artery bypass graft. At 3 years, the composite endpoint was significantly lower in the DES vs. BMS group (17.9% vs. 25.3%; P<.001). Comparisons between SES and each of the five other stent types yielded no significant differences for the primary composite endpoint: SES vs. paclitaxel-eluting stent (n = 350 pairs; 18.1% vs. 17.7%; P=.70); vs. zotarolimus-eluting stent (n = 474 pairs; 21.8% vs. 23.2%; P=.35); vs. Resolute zotarolimus-eluting stent (n = 434 pairs; 16.9% vs. 11.7%; P=.70); vs. everolimus-eluting stent (n = 824 pairs; 14.2% vs. 14.1%; P=.60); and vs. biolimus-eluting stent (n = 117 pairs 13.7% vs. 13.4%; P=.60).. Cardiac prognosis did not differ between sirolimus and other DES types. The use of DES was associated with better clinical outcomes compared to BMS. Topics: Aged; Comparative Effectiveness Research; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Long Term Adverse Effects; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Postoperative Complications; Prognosis; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome | 2014 |
Differential clinical outcomes after 1 year vs. 5 years in the SORTOUT III randomized comparison of zotarolimus- and sirolimus-eluting coronary stents.
Topics: Clinical Trials, Phase III as Topic; Coronary Restenosis; Drug-Eluting Stents; Humans; Immunosuppressive Agents; Prosthesis Design; Randomized Controlled Trials as Topic; Sirolimus; Treatment Outcome | 2014 |
Intravascular ultrasound assessment of optimal stent area to prevent in-stent restenosis after zotarolimus-, everolimus-, and sirolimus-eluting stent implantation.
The impact of underexpansion and minimal stent area (MSA) criteria in the second generation drug-eluting stents (DES) has not been addressed yet.. Using intravascular ultrasound (IVUS), we assessed the optimal cut-off values of post-stenting MSA to prevent in-stent restenosis (ISR). Poststenting IVUS data and 9-month follow-up angiography were available in 912 patients with 990 lesions: 541 sirolimus-eluting stents (SES), 220 zotarolimus-eluting stents (ZES) and 229 everolimus-eluting stents (EES).. For the prediction of angiographic ISR, the MSA of each DES was measured. The poststenting MSA was 6.4 ± 1.8 mm(2) in SES, 6.2 ± 2.1 mm(2) in ZES and 6.2 ± 2.1 mm(2) in EES. At the 9-months follow-up, the incidence of angiographic ISR was similar between SES (3.3%) vs. ZES (4.5%) vs. EES. (4.4%), (P = 0.53). Multivariable logistic regression analysis identified the post-stenting MSA as the only independent predictor of angiographic ISR in ZES (Odds ratio 0.722, 95% confidence interval 0.581-0.897, P = 0.001) and in EES (Odds ratio 0.595, 95% confidence interval 0.392-0.904, P = 0.015). The best MSA cut-off value was 5.5 mm(2) for the prediction of SES restenosis (sensitivity 72.2% and specificity 66.3%). For ZES, the optimal MSA predicting ISR was 5.3 mm(2) (sensitivity 56.7% and specificity 61.8%). For EES, the MSA <5.4 mm(2) predicted ISR (sensitivity 60.0% and specificity 60.0%).. As a preventable mechanism of ISR, smaller stent area predicted angiographic restenosis of the second generation DES as well as the first generation. The optimal cut-off values of post-stenting MSA for preventing restenosis were similar between ZES vs. EES vs. SES. Topics: Aged; Cardiovascular Agents; Chi-Square Distribution; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Everolimus; Female; Humans; Linear Models; Male; Middle Aged; Multivariate Analysis; Odds Ratio; Percutaneous Coronary Intervention; Predictive Value of Tests; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome; Ultrasonography, Interventional | 2014 |
Drug eluting stent neointimal regression: a welcomed change.
Topics: Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Male; Paclitaxel; Percutaneous Coronary Intervention; Sirolimus | 2013 |
Intravascular ultrasound predictors for edge restenosis after newer generation drug-eluting stent implantation.
The aim of the present study was to assess the intravascular ultrasound predictors for angiographic edge restenosis after newer generation drug-eluting stent implantation. A total of 820 patients (987 lesions) who underwent newer generation drug-eluting stent placement (236 Endeavor zotarolimus-eluting stents, 246 Resolute zotarolimus-eluting stents, and 505 everolimus-eluting stents) with 9 months of angiographic surveillance were enrolled. The post-stenting angiographic and intravascular ultrasound images of 1,668 reference segments (681 proximal and 987 distal) were analyzed. Overall, 37% of angiographically normal proximal reference segments and 21% of angiographically normal distal reference segments had plaque burden >50%. In the overall cohort of 1,668 reference segments, 47 (2.8%) had 9-month angiographic edge restenosis (diameter stenosis >50%). Edge restenosis was predicted by a post-stenting reference segment plaque burden >54.5% (sensitivity 81%, specificity 80%) and a reference segment minimum lumen area of 5.7 mm(2) (sensitivity 72%, specificity 59%). The edge restenosis rate was 2.1% in the Endeavor zotarolimus-eluting stents, 2.4% in the Resolute zotarolimus-eluting stents, and 3.4% in the everolimus-eluting stents lesions (p = 0.311). The predictive cutoff of the reference plaque burden was 56.3% for Endeavor zotarolimus-eluting stents, 57.3% for Resolute zotarolimus-eluting stents, and 54.2% for everolimus-eluting stents. The criteria for residual plaque burden were similar between proximal and distal reference segments (56.4% vs 51.9%, respectively), but the minimum lumen area criteria were quite different (<7.1 mm(2) for proximal vs <4.8 mm(2) for distal reference segments). In conclusion, after newer drug-eluting stent implantation, edge restenosis was predicted by post-stenting reference segment plaque burden >55%. Topics: Coronary Angiography; Coronary Restenosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Incidence; Male; Middle Aged; Myocardial Infarction; Prosthesis Failure; Reproducibility of Results; Republic of Korea; Retrospective Studies; Sirolimus; Time Factors; Ultrasonography, Interventional | 2013 |
Immediate and long-term results of a modified simultaneous kissing stenting for percutaneous coronary intervention of coronary artery bifurcation lesions.
We propose a modified simultaneous kissing stenting technique (MSKS) based on systematic implantation of a protective stent in the proximal main vessel (PMV) proximally to the bifurcation before simultaneous kissing stenting (SKS).. SKS has been proposed in large-size coronary vessel bifurcation lesions (BLs) when the PMV can accommodate two stents. SKS implies, however, low-pressure simultaneous final balloon inflations to avoid retrograde PMV dissection or rupture and therefore may not ensure optimal final stent apposition.. From January 2005 to May 2008, a total of 97 patients with 100 BLs (true bifurcation in 92%) who underwent MSKS were enrolled in a prospective registry. Drug-eluting stents were used for distal main vessel and side branch. Drug-eluting or large-size bare-metal stents were used as proximal protective stents.. Immediate procedural success rate was 100%. Global restenosis rate was 10% (5% in the main vessel and 8% in the side branch) at follow-up angiogram performed at 7 months in all patients (100%). No patient had early or late stent thrombosis. Two cases of non-fatal very late stent thrombosis occurred at 46 and 64 months. Over a mean 4.5-year follow-up period, target lesion revascularization rate was 11%, with only 3% driven by clinical ischemia.. Protective stent systematic implantation in the PMV represents a newly modified SKS technique that allows safe finalization of the procedure by high-pressure kissing balloon final inflation, ensuring optimal stent apposition with high immediate procedural success and low rates of long-term events. Topics: Aged; Angioplasty, Balloon, Coronary; Cohort Studies; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Incidence; Male; Metals; Middle Aged; Paclitaxel; Percutaneous Coronary Intervention; Prospective Studies; Retrospective Studies; Sirolimus; Stents; Treatment Outcome | 2013 |
Comparison of first- and second-generation drug-eluting stents in saphenous vein grafts used as aorto-coronary conduits.
Saphenous vein grafts (SVGs) are prone to an aggressive atherosclerotic process, and the efficacy of drug-eluting stents (DES) in treating this is still debated. In recent years, second-generation DES have been increasingly used in SVG intervention. The main objective of this study was to compare midterm clinical outcomes between first- and second-generation DES in SVGs because data regarding the use of second-generation DES in SVG are lacking. Patients treated with first-generation DES (127 patients with 143 lesions) and those treated with second-generation DES (84 patients with 100 lesions) were included in the study. Major adverse cardiac events, defined as the composite of all-cause death, myocardial infarction, and target vessel revascularization, as well as target vessel revascularization and target lesion revascularization separately, were evaluated at 30-day, 12-month, and 18-month follow-up. Baseline characteristics were similar between the 2 groups. Older grafts were treated with second-generation DES (11.6 ± 5.3 vs 14.3 ± 6.0 years, p = 0.001). Stent length was longer in the first-generation group (34.1 ± 25.1 vs 30.5 ± 19.4 mm, p = 0.006), and maximum balloon diameter was smaller in the second-generation group (3.42 ± 0.42 vs 3.30 ± 0.41 mm, p = 0.003). Embolic protection device use was higher in the second-generation DES group (55.2% vs 72.0%, p = 0.012). At 18-month follow-up, rates of major adverse cardiac events, target vessel revascularization, and target lesion revascularization for the first- and second-generation groups were 24.4% versus 20.2% (p = 0.479), 18.1% versus 14.2% (p = 0.465), and 15.0% versus 10.7% (p = 0.373), respectively. In conclusion, second-generation DES are at least comparable with first-generation DES with regard to clinical outcomes at midterm follow-up. Topics: Aged; Antineoplastic Agents; Cause of Death; Coronary Artery Bypass; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Male; Middle Aged; Paclitaxel; Postoperative Complications; Prosthesis Design; Reoperation; Sirolimus; Veins | 2013 |
One-year outcomes of percutaneous coronary intervention with the 38-mm Resolute zotarolimus-eluting stent.
This study was designed to prospectively evaluate the safety and efficacy of the 38-mm Resolute zotarolimus-eluting stent (R-ZES). Drug-eluting stents with long lengths are needed to ensure coverage of long lesions in some patients. Patients recruited from the RESOLUTE US and RESOLUTE Asia studies were implanted with at least one 38-mm R-ZES. Up to 2 lesions (in separate vessels) could be implanted with length ≤35 mm and a reference vessel diameter of 3.0 to 4.2 mm. The primary end point was 1-year target lesion failure, defined as cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. The 1-year target lesion failure rate using 1 vessel per patient was compared with a performance goal (19%) derived from historical data. There were 223 patients enrolled (n = 269 lesions). The mean age was 60.9 ± 10.9 years, 79% were men, and 38% had diabetes. Target lesion failure rate using a single-vessel analysis was 4.5%, and the upper limit of the 1-sided 95% confidence interval (7.5%) was less than the performance goal of 19%. A secondary analysis using all lesions resulted in a target lesion failure rate of 5.4% (upper limit of 1-sided 95% confidence interval, 8.6%). Baseline characteristics and clinical outcomes were similar between patients with and without diabetes. The rate of probable or definite stent thrombosis was 0.9%. In conclusion, the 38-mm length of the R-ZES was found to be safe and effective with a low rate of target lesion failure and stent thrombosis and no differences in outcomes between patients with and without diabetes. Topics: Coronary Angiography; Coronary Restenosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome | 2013 |
Clinical outcomes of the Resolute zotarolimus-eluting stent in patients with in-stent restenosis: 2-year results from a pooled analysis.
This study sought to assess the clinical safety and effectiveness of the Resolute zotarolimus-eluting stent (R-ZES) in patients with in-stent restenosis (ISR) from 2 large trials.. ISR treatment is associated with higher rates of subsequent cardiac events compared with treatment of de novo lesions. Although drug-eluting stents (DES) are an option, second-generation DES are largely untested in the treatment of ISR.. A total of 3,489 patients were pooled from the RAC (RESOLUTE All Comers) trial and the RESOLUTE International (RINT) registry. Two-year clinical endpoints included clinically driven target lesion revascularization (TLR), target lesion failure (TLF), cardiac death (CD), target vessel myocardial infarction (TVMI), combined CD or TVMI (CD/TVMI), and Academic Research Consortium definite and probable stent thrombosis (ST).. Overall, 281 patients (8.1%) received an R-ZES for ISR. Two-year TLR and TLF rates were significantly higher in ISR patients than in non-ISR patients (TLR: 12.7% vs. 4.3%, p = 0.003; TLF: 17.4% vs. 9.4%, p = 0.007); however, the CD/TVMI rate was not (6.9% vs. 6.1%, p = 0.711). Seven ISR patients had ST. Two-year outcomes by ISR stent type were similar: bare-metal stent (BMS)-ISR TLR was 12.5% and TLF was 17.2%; DES-ISR TLR was 13.0% and TLF was 18.8%. CD/TVMI was 7.3% and 7.2% for BMS-ISR and DES-ISR, respectively.. Using R-ZES to treat ISR appears equally safe in BMS-ISR and DES-ISR, with CD/TVMI rates comparable to 2-year outcomes in other clinical trials. Although revascularization rates are still higher in ISR lesions, the R-ZES offers an effective alternative for treatment of BMS-ISR and DES-ISR. (Randomized, Two-Arm, Non-inferiority Study Comparing Endeavor-Resolute Stent With Abbot Xience-V Stent [RESOLUTE-AC]; NCT00617084; and RESOLUTE International Registry: Evaluation of the Resolute Zotarolimus-Eluting Stent System in a 'Real-World' Patient Population [RINT]; NCT00752128). Topics: Aged; Cardiovascular Agents; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Logistic Models; Male; Middle Aged; Multivariate Analysis; Myocardial Infarction; Odds Ratio; Percutaneous Coronary Intervention; Propensity Score; Prosthesis Design; Randomized Controlled Trials as Topic; Registries; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2013 |
Nine-month angiographic and intravascular ultrasound outcomes after resolute zotarolimus-eluting stent implantation for the treatment of in-stent restenosis.
We aimed to evaluate the mid-term outcomes of resolute zotarolimus-eluting stent (R-ZES) implantation for in-stent restenosis (ISR).. There has been a paucity of data regarding the effects of new-generation drug-eluting stent to treat ISR.. From 2009 to 2010, a total of 98 patients with 98 ISR lesions were prospectively enrolled after R-ZES implantation for the treatment of ISR. Among 98 patients, 73 patients underwent follow-up angiography at 9 months. Serial intravascular ultrasound (IVUS) at both postprocedure and 9 months was evaluated in 55 patients. The overlapped segment of R-ZES was defined as the portion of R-ZES superimposed on previous stent.. Late loss and binary restenosis rate were 0.3 ± 0.5 mm and 5.5% at 9 months. On IVUS, the percentage of neointimal volume and maximum percentage of neointimal area were 3.9 ± 6.3% and 17.3 ± 15.5%, respectively. There was no significant change of vessel volume index between postprocedure and 9 months (16.9 ± 4.7 mm³ /mm vs. 17.1 ± 4.6 mm³ /mm, P = 0.251). Late-acquired incomplete stent apposition was observed in 5 (5/55, 9.1%) cases. Compared with nonoverlapped segments of R-ZES, the overlapped did not show larger neointimal volume index (0.3 ± 0.5 mm³ /mm vs. 0.2 ± 0.3 mm³ /mm, P = 0.187) on 9-month IVUS. During follow-up (median, 353 days), repeat target-lesion revascularization was performed in four cases, but there were no death or stent thrombosis.. This study suggested that R-ZES implantation for the treatment of ISR was effective up to 9 months and showed favorable vascular responses on serial IVUS assessment. Topics: Coronary Angiography; Coronary Restenosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Sirolimus; Time Factors; Treatment Outcome; Ultrasonography, Interventional | 2013 |
A completely fractured zotarolimus-eluting stent in an aortocoronary saphenous vein bypass graft.
Drug-eluting stents (DES) have significantly improved the rate of target vessel revascularization in comparison with bare metal stents. DES fracture was not reported in multicenter randomized clinical trials, but several case reports of DES fracture have been published, mostly with sirolimus-eluting stents. DES fracture is associated with stent restenosis and thrombosis. We report a zotarolimus-eluting stent fracture in an aortocoronary saphenous vein graft (SVG) bypass. The patient presented with chest pain and a non-ST-elevation myocardial infarction. He underwent cardiac catheterization that showed a complete fracture of a zotarolimus-eluting stent in the ostium of a sequential SVG to the diagonal and obtuse coronary arteries. His management included coronary angioplasty and retrieval of the proximal fractured segment. We discuss the potential causes for this stent fracture and suggest caution when using a DES in an ostial location of a SVG bypass, especially in a highly mobile vessel. Topics: Aged; Angioplasty, Balloon, Coronary; Coronary Angiography; Coronary Artery Bypass; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Follow-Up Studies; Humans; Male; Myocardial Infarction; Prosthesis Failure; Retreatment; Risk Assessment; Saphenous Vein; Severity of Illness Index; Sirolimus; Treatment Outcome | 2013 |
Major determinants for the uncovered stent struts on optical coherence tomography after drug-eluting stent implantation.
There have been little data regarding major determinants for the uncovered stent struts after drug-eluting stent (DES) implantation on optical coherence tomography (OCT). We investigated the major determinants of incomplete neointimal coverage of DES struts on OCT after implantation in a large cohort of patients. A total of 261 patients with 279 lesions who were treated with various DESs were selected from the OCT registry database. The lesions were divided into two groups based on the ratio of uncovered struts to total struts in all OCT cross-sections; an uncovered group (highest quartile with % uncovered struts ≥5.4%, n = 70), and covered group (the remaining lower quartiles with % uncovered struts <5.4%, n = 209). The uncovered group was more likely to have complex lesions, smaller reference vessel and stent diameter, and longer stent, more use of sirolimus-eluting stents, and less use of zotarolimus-eluting stents compared with the covered group. Of these variables, the most significant determinant of uncovered stent struts was DES type (odds ratio [OR] = 2.75, 95% confidence interval [CI] = 1.94-3.89, P < 0.001). The use of sirolimus-eluting stents (OR = 2.44, 95% CI, 1.15-5.47, P = 0.023) and zotarolimus-eluting stents (OR = 0.02, 95% CI = 0.01-0.25, P = 0.002) were the only significant risk and protective factors for uncovered stent struts, respectively. This study demonstrated that DES type might be associated with the most important determinants of uncovered struts compared to any other clinical or angiographic factor. Topics: Aged; Analysis of Variance; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Coronary Vessels; Drug-Eluting Stents; Everolimus; Female; Humans; Logistic Models; Male; Middle Aged; Odds Ratio; Paclitaxel; Predictive Value of Tests; Prosthesis Design; Registries; Republic of Korea; Risk Assessment; Risk Factors; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2012 |
Unprotected left main coronary artery stenting with zotarolimus (Endeavor) drug-eluting stents: a single center retrospective experience.
To report the safety and efficacy of zotarolimus eluting stents for treatment of unprotected left main coronary artery disease.. Percutaneous stent insertion is an increasingly popular alternative to bypass surgery for the management of left main (LM) coronary artery disease. While data support the use of sirolimus- and paclitaxel-coated stents in the LM coronary artery, there are no published series reporting results with Endeavor (zotarolimus) stents, particularly in the context of unprotected left main (ULM) lesions.. We retrospectively identified 40 consecutive patients who had ULM disease treated with Endeavor stents (ZES) and who had follow-up angiography. The primary endpoint was the prevalence of major adverse cardiac events (MACE), including cardiac/unexplained death, nonfatal myocardial infarction (MI), and in-stent restenosis (ISR)/target lesion revascularization (TLR).. Angiographic and procedural success was achieved in all cases. Follow-up angiography occurred on average 5.6 ± 0.9 months after the index procedure. There were three incidences of ISR requiring TLR and another patient who had a NSTEMI in the follow-up period. At late follow-up (12.4 ± 1.8 months) three patients underwent CABG (one for RCA stenosis) and four patients died without knowledge of the status of the ULM stent (two cardiovascular and two deaths related to cancer progression).. In conclusion, our experience with Endeavor stents for the treatment of ULM disease demonstrates excellent angiographic and clinical outcomes, with a 7.5% ISR/TLR rate and a 15% MACE rate, respectively, at an average clinical follow-up of 12.4 months. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Cause of Death; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Ontario; Prosthesis Design; Retrospective Studies; Risk Assessment; Risk Factors; Sirolimus; Time Factors; Treatment Outcome; Ultrasonography, Interventional | 2012 |
Inhibition of neointimal hyperplasia with a novel zotarolimus coated balloon catheter.
Non stent based delivery of antiproliferative agents using drug coated balloon catheters may offer additional flexibility and efficacy in a broad range of applications. The lipophilic antiproliferative drug zotarolimus makes it a potential candidate for balloon delivery. The aim of the present study was to evaluate the safety and efficacy of a prototype zotarolimus coated balloon (ZCB) catheter in comparison to a zotarolimus eluting stent (ZES) in the porcine coronary overstretch model.. Eighty-four stents (diameters 3.0 and 3.5 mm; length 15 mm) were implanted in LAD and Cx of 42 domestic pigs: control (TriMaxx, Abbott, polymer coated stent without drug, implanted with uncoated PCI catheter, n = 56); ZES (ZoMaxx, Abbott, stent coated with zotarolimus in polymer, implanted with uncoated PCI catheter, n = 14); ZCB (TriMaxx, Abbott, polymer coated stent without drug, implanted with zotarolimus coated PCI catheter, n = 14). Drug content of the vessel wall (n = 9) was measured about 10-30 min post intervention with ZCB in additional pigs.. Immediately after ZCB treatment 101 ± 31 μg of zotarolimus was detected in the coronary arteries. After 28 days ZES led to a reduction of neointimal area from 4.32 ± 1.45 to 3.32 ± 1.11 mm2 (P = 0.019 vs. control). The effect of neointimal inhibition was more pronounced with the novel ZCB (2.79 ± 1.43 mm², P = 0.001 vs. control). Inflammation score was significantly reduced in vessels treated with the ZCB (0.75 ± 0.86 compared to control (1.45 ± 0.94, P = 0.013) and ZES (1.65 ± 0.90, P = 0.012).. Zotarolimus coated balloons and stents were found to effectively reduce neointimal proliferation in the porcine coronary model. Inflammation scores were significantly reduced after treatment with the coated balloon. Zotarolimus balloon coating might be a novel option in preventing and treating restenosis. Topics: Angioplasty, Balloon, Coronary; Animals; Coronary Restenosis; Coronary Vessels; Disease Models, Animal; Drug-Eluting Stents; Hyperplasia; Neointima; Sirolimus; Swine | 2012 |
Outcomes of patients treated with the everolimus-eluting stent versus the zotarolimus eluting stent in a consecutive cohort of patients at a tertiary medical center.
In this study we compared the outcomes of the everolimus-eluting stent (EES) versus the zotarolimus-eluting stent (ZES) in patients treated at a tertiary medical center, with up to one year of follow-up.. Unselected consecutive patients were retrospectively recruited following stenting with the ZES (n = 197) or EES (n = 190). The first 100 consecutive patients in each cohort underwent syntax scoring. The primary endpoint of the study was target vessel failure, defined as the combined endpoint of cardiac death, non-fatal myocardial infarction, or target vessel revascularization. Secondary endpoints included target lesion revascularization, target lesion failure, acute stent thrombosis, total death, cardiac death, and non-fatal myocardial infarction.. The two groups were similar, including for Syntax scores (19.6 ± 12.8 versus 20.6 ± 13.6), number of stents per patient (2.9 ± 1.9 versus 2.9 ± 2.1), and cardiovascular risk factors. By one year, the primary outcome occurred in 20.8% EES versus 26.7% ZES (P = 0.19) patients. The secondary endpoints were as follows: target lesion revascularization (8.9% versus 20.6%, P = 0.003), target vessel revascularization (18.9% versus 25.6%, P = 0.142), definite and probable stent thrombosis (0% versus 2.5%), non-fatal myocardial infarction (2.7% versus 3.6%), and mortality (3.2% versus 5.1%) for the EES versus the ZES, respectively.. EES had similar target vessel failure to ZES, but superior target lesion revascularization and target lesion failure at one year of follow-up in an unselected cohort of patients. Topics: Aged; Aged, 80 and over; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chi-Square Distribution; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Everolimus; Female; Humans; Iowa; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Retrospective Studies; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2012 |
Short- and long-term outcomes with drug-eluting and bare-metal coronary stents: a mixed-treatment comparison analysis of 117 762 patient-years of follow-up from randomized trials.
Drug-eluting stents (DES) have been in clinical use for nearly a decade; however, the relative short- and long-term efficacy and safety of DES compared with bare-metal stents (BMS) and among the DES types are less well defined.. PubMed, Embase, and Cochrane Central Register of Controlled Trials (CENTRAL) were searched for randomized clinical trials, until March 2012, that compared any of the Food and Drug Administration-approved durable stent and polymer DES (sirolimus-eluting stent [SES], paclitaxel-eluting stent [PES], everolimus-eluting stent [EES], zotarolimus-eluting stent [ZES], and ZES-Resolute [ZES-R]) with each other or against BMS for de novo coronary lesions, enrolling at least 100 patients and with follow-up of at least 6 months. Short-term (≤ 1 year) and long-term efficacy (target-vessel revascularization, target-lesion revascularization) and safety (death, myocardial infarction, stent thrombosis) outcomes were evaluated and trial-level data pooled by both mixed-treatment comparison and direct comparison analyses. From 76 randomized clinical trials with 117 762 patient-years of follow-up, compared with BMS, each DES reduced long-term target-vessel revascularization (39%-61%), but the magnitude varied by DES type (EES~SES~ZES-R>PES~ZES>BMS), with a >42% probability that EES had the lowest target-vessel revascularization rate. There was no increase in the risk of any long-term safety outcomes, including stent thrombosis, with any DES (versus BMS). In addition, there was reduction in myocardial infarction (all DES except PES versus BMS) and stent thrombosis (with EES versus BMS: Rate ratio, 0.51; 95% credibility interval, 0.35-0.73). The safest DES appeared to be EES (>86% probability), with reduction in myocardial infarction and stent thrombosis compared with BMS. Short-term outcomes were similar to long-term outcomes, with SES, ZES-R, and everolimus-eluting stent being the most efficacious and EES being the safest stent.. DES are highly efficacious at reducing the risk of target-vessel revascularization without an increase in any safety outcomes, including stent thrombosis. However, among the DES types, there were considerable differences, such that EES, SES, and ZES-R were the most efficacious and EES was the safest stent. Topics: Aged; Angioplasty, Balloon, Coronary; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Metals; Middle Aged; Paclitaxel; Randomized Controlled Trials as Topic; Registries; Risk Factors; Sirolimus; Time; Treatment Outcome; Tubulin Modulators | 2012 |
Unrestricted use of endeavor resolute zotarolimus-eluting stent in daily clinical practice: a prospective registry.
To evaluate the safety and efficacy of unrestricted Endeavor Resolute zotarolimus-eluting stent (ZES) use. Furthermore, we sought to evaluate clinical outcomes associated with on- and off-label use of Resolute ZES.. The current study was a prospective, single-center registry. The primary endpoint was major adverse cardiac events (MACE), defined as the composite of death, myocardial infarction (MI), and target-vessel revascularization (TVR). Secondary endpoints were death, MI, TVR, and stent thrombosis (ST).. A total of 370 patients were prospectively enrolled. Off-label Resolute ZES use was performed in 311 patients (84%). At a mean follow-up of 17.3 ± 6 months, MACE occurred in 31 patients (8.5%), death in 15 (4.1%), MI in 10 (2.7%), and TVR in 19 (5.2%). Definite, probable, and possible ST occurred in 9 patients (2.5%). Off-label Resolute ZES implantation, as compared to on-label use, was not associated with an increased risk of MACE (9.4% vs 3.4%; P=.13), death (4.9% vs 0%; P=.14), MI (3.3% vs 0%; P=.38), and TVR (5.5% vs 3.4%; P=.75). On multivariable analysis, previous revascularization (P=.008), but not off-label Resolute ZES implantation (P=.07), was associated with MACE.. In daily clinical practice, Resolute ZES was mostly implanted in patients with off-label indications and associated with a relatively low rate of MACE and TVR. Topics: Angioplasty, Balloon, Coronary; Cohort Studies; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Logistic Models; Male; Multivariate Analysis; Off-Label Use; Prospective Studies; Prosthesis Failure; Registries; Risk Assessment; Sirolimus; Statistics, Nonparametric; Survival Rate; Treatment Outcome | 2012 |
Gender differences in patients treated with the zotarolimus-eluting stent at a tertiary medical center.
Gender-related differences in long-term outcomes of patients receiving the Endeavor zotarolimus-eluting stent (ZES) (Medtronic) have not been well defined. In this study, we evaluate the differences between men (M) and women (W) for 2-year target vessel failure (TVF) in an unselected consecutive series of patients treated with the ZES at our institution.. Data on 197 consecutive patients (133 M, 64 W) stented with the ZES were retrospectively analyzed. The primary endpoint of the study was to compare gender-related outcomes in TVF, defined as the combined endpoint of cardiac death, non-fatal myocardial infarction, and target vessel revascularization (TVR). Secondary endpoints included TLR, TVR, acute stent thrombosis (ST) as defined by the academic research consortium (ARC), and cardiac death. The cine angiograms of the first consecutive 122 patients (79 M, 43 W) were independently reviewed by a cardiologist blinded to clinical outcome and SYNTAX scoring was performed. Follow-up was achieved using medical records and/or phone calls and was censored at 730 days. Descriptive analysis was performed on all variables. Univariate analysis compared the M and W cohorts. Logistic regression analysis modeling for predictors of TVF was performed and survival analysis between the 2 groups was plotted.. The 2 groups were well matched for demographic, clinical, angiographic, and procedural variables. Angiographic complexity was also statistically similar between the 2 groups as judged by SYNTAX scoring (15.8 ± 10.9 M vs 13.5 ± 8.3 W; P=.197). At 2-year follow-up, TVF was 22.6% and 32.8% (P=.684) with no statistical difference between TLR (18.1% M vs 12.8% W), TVR (21.8% M vs 32.8% W), cardiac death (2.3% M vs 6.3% W), and definite and probable stent thrombosis (2.26% M vs 3.13% W). Logistic regression analyses modeling for age, gender, New York Heart Association (NYHA) class, non-left main (LM) bifurcation lesions, ostial lesions, trifurcating LM, and pre-percutaneous coronary intervention (PCI) lesion severity showed that a higher NYHA class (odds ratio [OR], 2.68; P=.005), ostial lesions (OR, 5.68; P<.001), bifurcating non-LM lesions (OR, 2.74; P=.015), and trifurcating LM lesions (OR, 28.24; P<.001) predicted a higher TVF. Female gender (P=.086) and age (P=.09) were not independent predictors of TVF.. In this cohort of patients receiving ZES, men and women had similar outcomes at 2-year follow-up consistent with recent reports in the current era of PCI. Complex coronary anatomy (ostial, non-LM bifurcations, and LM trifurcations) and advanced heart failure were stronger predictors of higher TVF than gender and age. Topics: Academic Medical Centers; Aged; Aged, 80 and over; Analysis of Variance; Angioplasty, Balloon, Coronary; Cohort Studies; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Electrocardiography; Female; Follow-Up Studies; Humans; Logistic Models; Male; Middle Aged; Multivariate Analysis; Prosthesis Failure; Retrospective Studies; Risk Assessment; Severity of Illness Index; Sex Factors; Sirolimus; Survival Rate; Treatment Outcome | 2012 |
Comparison of angiographic and IVUS follow-up between the two different drug-eluting stents implanted simultaneously in the same individuals.
While, theoretically, a drug-eluting stent (DES) with a biodegradable polymer should reduce the incidence of late in-stent thrombosis, this has not been experimentally tested.. This study compared long-term manifestations of the Excel DES, with a biodegradable polymer, to the Endeavor DES, with a biocompatible polymer, in the same individuals.. Forty-eight patients underwent simultaneous implantation of 1 or more Endeavor stents and 1 or more Excel stents, during the same procedure, and were evaluated with coronary angiography and intravascular ultrasound (IVUS) at least 1 year postprocedure. Within-patient comparisons were made between the Excel- and Endeavor-stented segments for efficacy and safety.. A total of 131 stents (69 Endeavor stents and 62 Excel stents) were implanted in 98 lesions among 48 patients. Baseline characteristics of the lesions in the two stented segments groups were comparable. Average follow-up duration was 14.3 ± 2.5 months. In-stent late luminal loss and luminal stenosis were higher in Endeavor-stented segments than in Excel-stented segments (P<.01). The binary restenosis rate was slightly higher in Endeavor-stented segments (4.3% vs. 1.6%; P=.379). In-stent thrombosis, late incomplete stent apposition, and uncovered stent struts were higher in Excel-stented segments than in Endeavor-stented segments (P<.01). There was 1 case of an in-stent coronary aneurysm with an Excel-stented segment. Four segments, in 4 cases (2 in each stent group), required target lesion revascularization.. This study suggested that, compared to DESs with a biocompatible polymer, DESs with biodegradable polymer do not appear to present an advantage for long-term safety. Topics: Aged; Antibiotics, Antineoplastic; Biocompatible Materials; Comparative Effectiveness Research; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Polymers; Postoperative Complications; Sirolimus; Treatment Outcome; Ultrasonography, Interventional | 2012 |
Endothelial progenitor cell response to antiproliferative drug exposure.
Vascular stent coverage by endothelial cells, derived from endothelial progenitor cells (EPC) is considered a surrogate for healing. However, the effects of antiproliferative drugs used in current drug-eluting stents (DES) on EPC proliferative and antithrombotic function remains poorly defined.. Herein, we studied and compared the in vitro and in vivo effects of four antiproliferative drugs - paclitaxel, sirolimus, everolimus, and zotarolimus on several EPC properties including colony forming units (CFU), cell proliferation, apoptosis, antithrombotic and prothrombotic gene expression and nitric oxide (NO) as well as prostacyclin (PGI(2)) release. We also examined EPC migration and adhesion under flow conditions. We find that whereas all antiproliferative agents inhibited EPC proliferation and caused cell apoptosis, only paclitaxel and sirolimus reduced CFU formation. Paclitaxel treatment also resulted in the greatest down-regulation of antithrombotic gene expression and up-regulation of prothrombotic gene expression. NO release, migration, and adhesion of EPC under shear stress were inhibited by all antiproliferative drugs, most notably by paclitaxel and sirolimus.. These results indicate that antiproliferative drugs on DES, particularly paclitaxel, impair the proliferative and antithrombotic functions of EPC, and thereby could contribute to incomplete vascular healing and increase the risk of stent thrombosis. Topics: Animals; Apoptosis; Cell Adhesion; Cell Movement; Cell Proliferation; Cells, Cultured; Coronary Restenosis; Drug-Eluting Stents; Endothelial Cells; Endothelium, Vascular; Epoprostenol; Everolimus; Humans; Male; Nitric Oxide; Paclitaxel; Rats; Sirolimus; Stem Cells; Stents | 2012 |
Serial optical coherence tomography-based observation of strut coverage on drug-eluting stent crossing side-branch vessels.
Serial changes in strut coverage of drug-eluting stents (DESs), which are placed across side-branch vessels, remain unclear.. The changes in strut coverage of DESs crossing side-branch vessels (size ≥2.0 mm) were serially evaluated by optical coherence tomography (OCT) in 30 patients at 9 months and 2 years after the index DES implantation. DESs were paclitaxel-eluting stents (PESs), sirolimus-eluting stents (SESs), and zotarolimus-eluting stents (ZESs), each in 10 patients. Measured neointimal hyperplasia (NIH) thickness of 0 μm on OCT was defined as an uncovered strut.. The percentage of uncovered side-branch struts significantly decreased from 55.7 ± 39.9% to 36.6 ± 32.0% (P<.0001) on serial follow-up: PES, 93.4 ± 10.5% to 67.6 ± 24.2%, P=.018; SES, 47.5 ± 34.4% to 29.6 ± 24.1%, P=.036; and ZES, 26.2 ± 34.8% to 12.4 ± 19.0%, P=.028. Among covered side-branch struts, the overall percentage of struts with NIH thickness more than 30 μm significantly increased from 36.3 ± 37.4% to 51.0 ± 36.0% (P<.0001). However, compared to other DES types, a significant increase in relatively thin NIH (0 to 30 μm) was observed in PESs (1.6 ± 3.4% to 17.4 ± 16.0%; P=.018).. Serial follow-up OCT examination showed a significant decrease in the percentage of uncovered side-branch struts, and the coverage pattern differed with DES type. Topics: Aged; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Incidence; Male; Middle Aged; Neointima; Paclitaxel; Percutaneous Coronary Intervention; Retrospective Studies; Sirolimus; Time Factors; Tomography, Optical Coherence | 2012 |
Stent fracture and restenosis after zotarolimus-eluting stent implantation.
Stent fracture (SF) has been found in peripheral and coronary vasculatures, and in the latter mostly after implantation of sirolimus- or paclitaxel-eluting stents. We report a patient with a fractured stent associated with restenosis after zotarolimus-eluting stent (ZES) implantation which was confirmed by fluoroscopy, intravascular ultrasound and computerized tomography. To our knowledge, this is the first published report of SF after ZES implantation. Topics: Aged; Angioplasty, Balloon, Coronary; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Humans; Male; Prosthesis Failure; Radiography; Sirolimus; Ultrasonography | 2011 |
Comparative assessment of mammalian target of rapamycin inhibitor-eluting stents in the treatment of coronary artery bifurcation lesions: the CASTOR-Bifurcation registry.
Drug-eluting stents (DES) have revolutionized the treatment of coronary bifurcation lesions. Among different DES types, sirolimus-eluting stents (SES) showed better outcomes than paclitaxel-eluting stents. Because novel sirolimus analogues have been implemented in DES, a prospective observational comparison was undertaken to compare major mammalian target of rapamycin inhibitor-eluting stents in the treatment of bifurcation lesions according to the provisional T-stenting and small protrusion (TAP) technique. Overall, 187 patients (165 men, 65 ± 10 years) were enrolled in the study: 80 patients received a SES, whereas zotarolimus-eluting stents (ZES) were implanted in 53 patients and everolimus-eluting stents (EvES) in 62 patients. Primary end-point of the study was the 12-month incidence of target bifurcation failure (TBF) defined as occurrence of cardiovascular death, nonfatal myocardial infarction (MI), and target vessel revascularization (TVR) or angiographic documentation of > 50% restenosis on the main vessel or TIMI flow < 3 on the side branch. Groups were homogeneous according to main clinical and angiographic characteristics. Overall, 17 (9.1%) patients had TBF: 4 (2.1%) patients had nonfatal non-ST-segment elevation MI, 9 (4.8%) patients underwent TVR, and 6 (3.2%) patients had an angiographic restenosis. The rate of TBF was statistically different among the three groups (7.9% in SES group, 18% in ZES group, and 3.3% in EvES group, P = 0.024). Previous MI was associated with a worse outcome (P = 0.025), whereas final kissing balloon was associated with a better outcome (P = 0.045). In conclusion, in this prospective registry, significant differences between DES were found in the outcome of patients treated for coronary bifurcation lesions according to provisional TAP technique. Thus, prospective randomized trials in this field are needed. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chi-Square Distribution; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Everolimus; Female; Humans; Italy; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Proportional Hazards Models; Prospective Studies; Prosthesis Design; Registries; Risk Assessment; Risk Factors; Sirolimus; Time Factors; TOR Serine-Threonine Kinases; Treatment Outcome | 2011 |
Procedural and clinical evaluation of the novel zotarolimus-eluting resolute stent in patients with unselected bifurcated coronary stenosis treated by provisional approach: a multicenter registry.
As data on the use of the latest-generation drugeluting stents (DES) in bifurcation interventions are lacking, we realized a multicenter registry to assess the procedural and clinical results obtained in patients with unselected bifurcated lesions treated with the novel zotarolimus-eluting Resolute stent (ZRS).. Three Italian centers participated in the study. Consecutive patients with significant stenosis of bifurcated lesions undergoing DES implantation were treated with ZRS. The recommended technique was the "provisional TAP approach" [main-vessel (MV) stent implantation eventually followed by kissing balloon and sidebranch (SB) stenting according to TAP technique]. Clinical characteristics, procedural details and clinical follow-up data were prospectively recorded. Procedural success was defined as post-percutaneous coronary intervention visual stenosis > 20% on MV and TIMI 3 flow on both MV and SB. Primary endpoint was major adverse coronary events (cardiac death, myocardial infarction and target vessel revascularization) at 9-month follow up. A total of 180 patients were enrolled. The target lesion was located in the distal left main in 16% and in the left anterior descending artery in 52%. All but 3 cases were treated according to the provisional TAP approach (kissing balloon rate, 69%; overall SB stenting rate, 10.6%). Procedural success was obtained in 98.3% (3 failures due to final SB TIMI flow < 3). At 9-month follow up, the survival free from MACE was 97.8% (1 cardiac death and 3 repeat revascularizations).. The use of the latest-generation ZRS in unselected bifurcated lesions treated by a provisional approach is associated with excellent procedural results and with promising clinical outcomes. Topics: Aged; Angioplasty, Balloon, Coronary; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Incidence; Italy; Male; Middle Aged; Myocardial Infarction; Registries; Retrospective Studies; Risk Factors; Sirolimus; Survival Rate; Treatment Outcome | 2011 |
Long-term safety and efficacy of drug-eluting stents.
Topics: Coronary Angiography; Coronary Restenosis; Death, Sudden, Cardiac; Drug-Eluting Stents; Everolimus; Humans; Immunosuppressive Agents; Multicenter Studies as Topic; Myocardial Infarction; Myocardial Revascularization; Randomized Controlled Trials as Topic; Secondary Prevention; Sirolimus; Treatment Outcome | 2011 |
Clinical outcome, angiographic outcome, and coronary endothelial function after drug-eluting stent implantation.
Topics: Coronary Angiography; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Endothelium, Vascular; Humans; Myocardial Revascularization; Paclitaxel; Sirolimus | 2011 |
Spatial distribution of neo-intimal hyperplasia 6 months after zotarolimus-eluting stent implantation, analysed by optical coherence tomography.
Optical coherence tomography is a high-resolution imaging technology that allows in vivo assessment of neointimal hyperplasia and strut coverage after coronary stenting.. Assessment of spatial distribution of healing, 6 months after zotarolimus-eluting stent implantation.. Forty-two zotarolimus-eluting stents were monitored by optical coherence tomography 6 months after implantation. Mean neointimal strut coverage thickness and percentage of neointimal hyperplasia were measured every millimetre. Non-covered strut ratios were assessed on each slice. In addition, the spatial distribution of neointimal hyperplasia and strut coverage were analysed longitudinally on five stent segments and axially on each slice.. There were no clinical events at 6 months under dual antiplatelet therapy. The optical coherence tomography analysis showed a mean neointimal hyperplasia thickness of 333±147μm and neointimal hyperplasia obstruction of 36.1±12.3%. The percentage of covered struts at 6 months was very high (98.9%). Only 6/745 slices analysed (0.8%) had non-covered strut ratios exceeding 30%. There was no significant heterogeneity in either longitudinal or axial neointimal hyperplasia distribution. No thrombi were observed.. This optical coherence tomography study found relatively constant neointimal hyperplasia thickness, regardless of the zotarolimus-eluting stent length or diameter. This spatially homogeneous neointimal hyperplasia was associated with near-total coverage of all struts, 6 months after implantation. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Vessels; Drug Therapy, Combination; Drug-Eluting Stents; Female; France; Humans; Hyperplasia; Male; Middle Aged; Platelet Aggregation Inhibitors; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Tunica Intima | 2011 |
My stent is better than your stent...Or is it?
Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Humans; Myocardial Infarction; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2011 |
Dual antiplatelet therapy duration and clinical outcomes following treatment with zotarolimus-eluting stents.
We sought to evaluate differences in late safety outcomes relative to dual antiplatelet therapy (DAPT) duration in patients treated with zotarolimus-eluting stents (ZES).. Despite treatment recommendations for at least 12 months of DAPT following drug-eluting stent revascularization, device-specific outcomes relative to DAPT duration are absent.. Among 2,032 patients undergoing percutaneous coronary revascularization with ZES in 5 trials, late safety events were compared relative to DAPT duration for patients with ≥ 6 months DAPT adherence and survival free of major ischemic and bleeding events.. A total of 1,414 event-free patients on DAPT at 6 months were identified. Patient group comparisons relative to DAPT included: 6 months versus ≥ 12 months, and 6 months versus ≥ 24 months. Through 3 years, risk-adjusted ischemic event rates did not significantly differ between groups: 6 versus ≥ 12 months: death (2.7% vs. 2.2%), myocardial infarction (MI, 0.3% vs. 1.1%), and definite/probable stent thrombosis (ST, 0.3% vs. 0%); 6 versus ≥ 24 months: death (1.6% vs. 1.6%), MI (0.4% vs. 1.2%), and definite/probable ST (0.1% vs. 0.2%). Composite events also did not statistically vary between DAPT durations. In multivariable analysis, 6-month versus longer DAPT duration was not associated with increased likelihood of thrombotic events at 3-year follow-up. Major bleeding was negligible across groups.. Among patients treated with ZES, late-term events of death, MI, stroke, and ST do not significantly differ between patients taking 6 months DAPT compared with continuation beyond 1 year. These findings merit further study to identify the appropriate duration of DAPT according to specific drug-eluting stents. Topics: Antineoplastic Agents, Phytogenic; Aspirin; Belgium; Confidence Intervals; Coronary Restenosis; Drug-Eluting Stents; Female; France; Humans; Immunosuppressive Agents; Male; Middle Aged; Multivariate Analysis; Odds Ratio; Paclitaxel; Platelet Aggregation Inhibitors; Risk Assessment; Sirolimus; Thienopyridines; Time Factors; Treatment Outcome; United States | 2011 |
Will we ever know the optimal duration of dual antiplatelet therapy after drug-eluting stent implantation?
Topics: Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Immunosuppressive Agents; Male; Platelet Aggregation Inhibitors; Sirolimus; Thienopyridines | 2011 |
Comparison of outcomes between Zotarolimus- and sirolimus-eluting stents in patients with ST-segment elevation acute myocardial infarction.
Zotarolimus-eluting stents (ZESs) demonstrated greater in-segment late luminal loss and in-segment binary restenosis rates compared to sirolimus-eluting stents (SESs) in several studies. However, no data are available in direct comparison between the clinical outcomes of the 2 stents in unselected patients with ST-segment elevation acute myocardial infarction (STEMI). The aim of the present study was to compare the clinical outcomes of ZESs and SESs in real-world patients with STEMI. A total of 873 patients with STEMI (306 patients in the ZES group and 567 patients in the SES group) were enrolled in a nationwide prospective Korea Acute Myocardial Infarction Registry (KAMIR) from January 2007 to January 2008. The primary end points were major adverse cardiac events, a composite of all causes of death, myocardial infarction, and target lesion revascularization during a 12-month clinical follow-up. During 1 year of follow-up, the primary end points occurred in 140 patients (16.0%). The use of glycoprotein IIb/IIIa inhibitors and the occurrence of multivessel disease were more common in the SES group. The SES group had a significantly lower incidence of major adverse cardiac events (hazard ratio [HR] 1.52, 95% confidence interval [CI] 1.07 to 2.16, p = 0.02), target lesion revascularization (HR 2.16, 95% CI 1.01 to 4.59, p = 0.046), and target vessel revascularization (HR 2.24, 95% CI 1.18 to 4.24, p = 0.013). However, no significant differences were found in death or myocardial infarction (HR 1.37, 95% CI 0.91 to 2.05, p = 0.129). In conclusion, SESs provided superior angiographic outcomes, translating into better clinical outcomes and negating any change in STEMI patient safety profiles compared to ZESs. Topics: Aged; Angioplasty, Balloon, Coronary; Coronary Angiography; Coronary Restenosis; Drug-Eluting Stents; Electrocardiography; Female; Humans; Male; Middle Aged; Myocardial Infarction; Sirolimus; Thrombosis | 2010 |
Sorting out drug-eluting stents.
Topics: Coronary Restenosis; Drug-Eluting Stents; Humans; Randomized Controlled Trials as Topic; Sirolimus; Thrombosis | 2010 |
Twelve-month outcomes in patients with diabetes implanted with a zotarolimus-eluting stent: results from the E-Five Registry.
To retrospectively evaluate the 12-month effectiveness of the Endeavor zotarolimus-eluting stent (ZES) in diabetic versus non-diabetic patients enrolled in the E-Five Registry.. The E-Five Registry is a prospective, multicentre registry of 8314 patients presenting with symptomatic coronary artery disease treated with the Endeavor (ZES). Patients were treated at 188 centres located in 37 countries across Europe, Latin America and Asia Pacific.. There were 2721 (32.7%) patients with diabetes (DM) and among these patients 682 were insulin-treated (ITDM) and 2039 were non-insulin-treated diabetic patients (NITDM). Interventions All enrolled patients received an Endeavor ZES and were followed for 12 months.. The primary outcome measure was major adverse cardiac event (MACE) at 12 months. Secondary endpoints included target lesion revascularisation (TLR), target vessel revascularisation (TVR), target vessel failure (TVF) and stent thrombosis.. Compared with non-DM patients, DM patients had higher rates of MACE (9.7% vs 6.4%, p<0.001), TLR (5.3% vs 4.0%, p=0.028) and Academic Research Consortium (ARC) definite and probable stent thrombosis (1.5% vs 0.9%, p=0.041). Compared with non-DM patients, ITDM patients had higher rates of MACE (12.6% vs 6.4%, p<0.001). ITDM patients had higher rates of death (6.7% vs 1.7%, p<0.001), cardiac death (4.5% vs 1.2%, p<0.001) and TLR (6.5% vs 4.0%, p=0.011) than non-DM patients.. The Endeavor ZES performed well in DM patients; however, DM patients experienced higher rates of adverse clinical events compared with non-DM patients. TRIAL REG NO:. http://www.clinicaltrials.gov; Unique identifier: NTC00623441. Topics: Aged; Angioplasty, Balloon, Coronary; Coronary Artery Disease; Coronary Restenosis; Diabetes Mellitus; Drug-Eluting Stents; Epidemiologic Methods; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Registries; Sirolimus; Thrombosis; Treatment Outcome | 2010 |
Clinical and angiographic outcomes of drug-eluting stents in patients with large vessel and single coronary artery lesion.
The aim of this study was to evaluate and compare the clinical and angiographic outcomes of 3 drug-eluting stents (DES) in patients with large vessel diameter and single coronary artery lesions.. The efficacy of 3 DESs may be similar.. A total of 411 consecutive patients who visited 3 university hospitals from June 2004 to December 2007 and had a single coronary lesion which was treated with the use of a DES that was 3.5 mm in diameter were enrolled in this study. Patients were divided into 3 stent groups: Paclitaxel-eluting stent (PES, n = 105), Sirolimus-eluting stent (SES, n = 259), and Zotarolimus-eluting stent (ZES, n = 47). The study end point was a composite of major adverse cardiac events (MACE) including cardiac death, myocardial infarction (MI), and ischemia-driven target-vessel revascularization (TVR) for 12 months.. Baseline characteristics were not different. Late loss was higher in the ZES group than the other stents (0.5 +/- 0.4 mm in SES vs 0.3 +/- 0.5 mm in PES, 0.7 +/- 0.5 mm in ZES, P = 0.001). The total MACE-free survival rate was not significantly different between the SES group and the PES group (98.8% in SES vs 97.1% in PES, P = 0.252) or the PES group and the ZES group (97.1% in PES vs 93.6% in ZES, P = 0.301). However, the SES group showed a significantly better MACE-free survival rate compared with the ZES group (98.8% in SES vs 93.6% in ZES, P = 0.018).. Clinical and angiographic outcomes of DES in a large vessel diameter and single coronary artery is excellent and SES appears to show better angiographic and clinical outcomes than ZES. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chi-Square Distribution; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Disease-Free Survival; Drug-Eluting Stents; Female; Hospital Mortality; Hospitals, University; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Paclitaxel; Prosthesis Design; Republic of Korea; Risk Assessment; Risk Factors; Severity of Illness Index; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2010 |
Sex-specific outcomes following revascularization with zotarolimus-eluting stents: comparison of angiographic and late-term clinical results.
We examined angiographic and late-term clinical outcomes according to sex in recent percutaneous coronary intervention (PCI) trials involving zotarolimus-eluting stents (ZES).. Differences in outcome between men and women undergoing PCI have been inconsistently described with bare metal and first-generation drug-eluting stents.. Clinical and angiographic outcomes among ZES-treated patients were evaluated by sex using propensity score modeling in a patient-level systematic overview of six trials and were also compared to patients receiving bare metal stents (BMS).. Among 2,132 patients, 608 were female (28.5%). Compared to men, women were older and more frequently had diabetes, hypertension, and a smaller reference vessel diameter (P < 0.05 for all). For both sexes, the relative reductions in 8-month angiographic binary restenosis and late lumen loss were statistically significant and of similar extent with ZES compared to BMS. By 2 years, treatment with ZES resulted in significantly lower target vessel revascularization (TVR) and target vessel failure (TVF; 10.0% vs. 21.5%, P = 0.0003) among women that paralleled risk reductions for men. However, among ZES-treated patients, 2-year rates of TVR (8.2% vs. 10.4%, P = 0.005) and TVF (9.9% vs. 12.8%, P = 0.004) were significantly lower among women, although rates of death and myocardial infarction were similar.. Despite greater baseline clinical and angiographic risk than men, women undergoing PCI with ZES compared to BMS experienced significant reductions in angiographic restenosis and repeat revascularization yet similar safety. Among all patients treated with ZES, late-term safety and efficacy outcomes are similar, if not lower, among women compared to men. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Clinical Trials as Topic; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Female; Humans; Logistic Models; Male; Middle Aged; Predictive Value of Tests; Propensity Score; Prosthesis Design; Retrospective Studies; Risk Assessment; Risk Factors; Sex Factors; Sirolimus; Time Factors; Treatment Outcome | 2010 |
Comparison of vascular response to zotarolimus-eluting stent vs paclitaxel-eluting stent implantation: pooled IVUS results from the ZoMaxx I and II trials.
The ZoMaxx I and II trials were randomized controlled studies of the zotarolimus-eluting, phosphorylcholine-coated, TriMaxx stent for the treatment of de novo coronary lesions. The aim of this study was to compare the vessel response between zotarolimus- (ZES) and paclitaxel-eluting stents (PES) using intravascular ultrasound (IVUS).. Data were obtained from the ZoMaxx I and II trials, in which a standard IVUS parameter was available in 263 cases (baseline and 9-months follow up). Neointima-free frame ratio was calculated as the number of frames without IVUS-detectable neointima divided by the total number of frames within the stent. While an increase in vessel and plaque was observed in PES from baseline to follow up, there was no significant change in ZES. At follow up, % neointimal obstruction was significantly higher (15.4 ± 8.8% vs 11.3 ± 9.7%), and minimum lumen area at follow up was significantly smaller in ZES compared to PES. However, the incidence of IVUS-defined restenosis (maximum cross-sectional narrowing >60%) was similar in the 2 groups (3.2% vs 6.7%). Neointima-free frame ratio was significantly lower in ZES. There were 5 cases of late incomplete stent apposition in PES and none in ZES.. These IVUS results demonstrate a similar incidence of severe narrowing between these 2 DES. There was a moderate increase in neointimal hyperplasia that was associated with a greater extent of neointimal coverage in ZES compared with PES. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chi-Square Distribution; Coronary Angiography; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Hyperplasia; Male; Middle Aged; Multicenter Studies as Topic; Paclitaxel; Prosthesis Design; Randomized Controlled Trials as Topic; Risk Assessment; Risk Factors; Sirolimus; Time Factors; Treatment Outcome; Tunica Intima; Ultrasonography, Interventional | 2010 |
Neovascular microchannels in sirolimus-eluting stent occlusion at late phase.
Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Cell Proliferation; Coronary Angiography; Coronary Occlusion; Coronary Restenosis; Drug-Eluting Stents; Humans; Male; Microvessels; Middle Aged; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2010 |
Gender medicine and drug eluting coronary stents.
Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Female; Humans; Male; Predictive Value of Tests; Prosthesis Design; Risk Assessment; Risk Factors; Sex Factors; Sirolimus; Time Factors; Treatment Outcome | 2010 |
Long-term clinical outcomes with zotarolimus-eluting versus bare-metal coronary stents.
This study sought to evaluate the long-term safety of the zotarolimus-eluting stent (ZES) using a pooled analysis of pivotal trials.. Drug-eluting stents, compared with bare-metal stents (BMS), have reduced restenosis; however, individual trials of these stents have not had sufficient power to ascertain long-term safety.. We combined patient level data from 6 prospective randomized single-arm multicenter trials involving 2,132 patients treated with ZES and 596 patients treated with a BMS control. The median follow-up was 4.1 years, with 5-year follow-up completed in 1,256 patients (97% of those eligible). The recommended minimum duration of dual antiplatelet therapy in these studies was 3 to 6 months regardless of stent type. An independent events committee adjudicated all events. The 2 treatment groups were compared after adjustment for between trial variation and for individual patient clinical and angiographic characteristics by propensity score.. The cumulative incidence of adverse events at 5 years for ZES and BMS were: death: 5.9% versus 7.6% (adjusted hazard ratio: 0.81, p = 0.34), cardiac death: 2.4 versus 3.7% (0.83, p = 0.57), myocardial infarction: 3.4 versus 4.8% (0.77, p = 0.37), target lesion revascularization: 7.0% vs. 16.5% (0.42, p < 0.001), stent thrombosis (definite or probable): 0.8 versus 1.7% (0.50, p = 0.21). After adjustment for variation in study and patient characteristics, there were no significant differences in stent thrombosis or the clinical safety event rates at 5 years between ZES and BMS.. Over 5 years, there was no increased risk of death, myocardial infarction, or stent thrombosis, and there was a benefit of prevention of repeat revascularization procedures in ZES compared with BMS. Topics: Confidence Intervals; Coronary Artery Disease; Coronary Restenosis; Female; Humans; Immunosuppressive Agents; Incidence; Male; Middle Aged; Proportional Hazards Models; Randomized Controlled Trials as Topic; Sirolimus; Statistics, Nonparametric; Time Factors; Treatment Outcome; United States | 2010 |
Correlation between quantitative angiographic and intravascular ultrasound parameters in patients treated with sirolimus analogous-eluting stents.
Despite the undeniable contribution of intravascular ultrasound (IVUS) and quantitative coronary angiography (QCA) to assess drug-eluting stent (DES) effectiveness, the way these image modalities correlate to each other and to target-lesion revascularization (TLR) after PCI, is yet to be established. Thus we sought to evaluate whether there is an acceptable correlation between QCA and IVUS after DES implantation. We analyzed 204 pts treated with DES: Zotarolimus- (126), Sirolimus- (57), and Biolimus (31) with baseline and follow-up QCA and IVUS. The correlation between QCA lumen loss (LL) and intimal hyperplasia (IH) volume obstruction by IVUS was assessed by multiple regression analysis. Two QCA parameters (in-segment diameter stenosis and in-segment LL) and one IVUS variable (in-stent volume of IH) were evaluated as quantitative surrogates of 6 month TLR. The receiver operating characteristic method with c-statistics was used to assess the ability of each surrogate endpoint to predict TLR. QCA LL correlated positively with IVUS IH volume of obstruction (r = 0.69; CI95% 0.61-0.75: P < 0.0001), independent of DES type. The 2 QCA parameters were superior to the IVUS parameter as surrogates for TLR. Of note, QCA LL (c = 0.99) correlated best with TLR, even better than percent DS. In the DES era there is a good correlation between QCA measured LL and IVUS IH volume and therefore can be used as a surrogate of DES efficacy. Topics: Coronary Angiography; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Prospective Studies; Regression Analysis; ROC Curve; Sirolimus; Ultrasonography, Interventional | 2009 |
Optical coherence tomography to diagnose under-expansion of a drug-eluting stent.
Topics: Acute Coronary Syndrome; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Drug-Eluting Stents; Humans; Male; Middle Aged; Predictive Value of Tests; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2009 |
Differences in restenosis rate with different drug-eluting stents in patients with and without diabetes mellitus: a report from the SCAAR (Swedish Angiography and Angioplasty Registry).
Our aim was to evaluate restenosis rate of drug-eluting stents (DES) in patients with and without diabetes mellitus (DM) in a real-world setting.. DES seem less effective in patients with DM.. The SCAAR (Swedish Coronary Angiography and Angioplasty Registry) includes all patients undergoing percutaneous coronary intervention in Sweden. From April 1, 2004, to April 20, 2008, all restenoses detected at a subsequent angiography and all DES types implanted at more than 500 occasions were assessed using Cox regression.. Four DES types qualified for inclusion. In total, 35,478 DES were implanted at 22,962 procedures in 19,004 patients and 1,807 restenoses were reported over a mean 29 months follow-up. In the entire population, the restenosis rate per stent was 3.5% after 1 year and 4.9% after 2 years. The adjusted risk of restenosis was higher in patients with DM compared with that in patients without DM (relative risk [RR]: 1.23, 95% confidence interval [CI]: 1.10 to 1.37). In patients with DM, restenosis was twice as frequent with the zotarolimus-eluting Endeavor stent (Medtronic, Minneapolis, Minnesota) compared with that in the other DES types. The Endeavor stent and the sirolimus-eluting Cypher stent (Cordis, Johnson & Johnson, Miami, Florida) had higher restenosis rates in patients with DM compared with those in patients without DM (RR: 1.77, 95% CI: 1.29 to 2.43 and RR: 1.25, 95% CI: 1.04 to 1.51). Restenosis rate with the paclitaxel-eluting Taxus Express and Liberté (Boston Scientific, Natick, Massachusetts) stents was unrelated to DM. Mortality did not differ between different DES.. Restenosis rate with DES was higher in patients with DM compared with that in patients without DM. There seem to be important differences between different brands of DES. Topics: Aged; Case-Control Studies; Confidence Intervals; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Databases as Topic; Diabetes Complications; Drug-Eluting Stents; Female; Humans; Immunosuppressive Agents; Male; Paclitaxel; Proportional Hazards Models; Registries; Risk; Sirolimus; Sweden; Tubulin Modulators | 2009 |
Different vascular response to concurrent implantation of sirolimus- and zotarolimus-eluting stents in the same vessel.
Drug-eluting stents (DES) have become routine therapy in clinical practice because restenosis is significantly reduced in patients treated with these devices. New generations of DES bearing newer antiproliferative drugs have been developed. Sirolimus was the first antiproliferative drug eluted by a DES (SES) while zotarolimus represents a sirolimus-derived, newer antiproliferative drug borne by a different kind of DES (ZES). This report describes two cases of different vascular response to concurrent side by side implantation of SES and ZES in the same vessel and highlights significant early restenosis of ZES as compared with SES. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug Therapy, Combination; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Platelet Aggregation Inhibitors; Prosthesis Design; Sirolimus; Treatment Outcome | 2009 |
Angiographic and intravascular ultrasound findings following implantation of the Endeavor zotarolimus-eluting stents in patients from the real-world clinical practice.
The aim of this study was to investigate the angiographic and intravascular ultrasound (IVUS) findings of the Endeavor zotarolimus-eluting stent (ZES) in patients from a "real-world" clinical practice.. From January to March 2006, 100 patients undergoing routine or emergency percutaneous intervention were prospectively enrolled at one institution. Overall, 39% of the patients were diabetics and 80.8% of lesions were type B2/C. A total of 140 lesions were successfully treated with 174 ZES, and procedural success was 98%. Mean vessel diameter was 2.69 mm and mean lesion length was 16.0 mm; at 6-month angiographic follow-up (completed in 96%), in-stent late lumen loss was 0.66 mm, and in-segment restenosis was 8.2%. Angiographic restenosis was increased among diabetics (15.5 vs. 2.6%, p=0.009), and diabetes was the only significant predictor of angiographic restenosis (OR=15.27 [95%CI 2.45-95.04], p=0.003). By IVUS (performed in 88% at 6-month), % volume obstruction was 14.4+/-13.4%, and there was no late acquired incomplete stent apposition (ISA). At 1-year, overall MACE rate was 6%, including 5 TLRs (4% of patients), with no occurrence of stent thrombosis.. In this prospective "real-world" experience, the ZES demonstrated favourable angiographic and IVUS results in complex patients, with overall in-stent late lumen loss of 0.66 mm, and absence of late acquired ISA. At 1-year, there were no safety concerns including absence of death and stent thrombosis. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Prospective Studies; Prosthesis Design; Registries; Risk Assessment; Risk Factors; Sirolimus; Thrombosis; Time Factors; Treatment Outcome; Ultrasonography, Interventional | 2009 |
Lack of clinical benefit of improved angiographic results with sirolimus-eluting stents compared with paclitaxel and zotarolimus-eluting stents in patients with acute myocardial infarction undergoing percutaneous coronary intervention.
There is limited information regarding the angiographic and clinical outcomes among the different drug-eluting stents (DESs) in patients with acute myocardial infarction (AMI) undergoing percutaneous coronary intervention (PCI).. A total 355 consecutive AMI patients who underwent PCI with a sirolimus- (SES, n=116) or paclitaxel- (PES, n=153) or zotarolimus-eluting stent (ZES, n=86) were enrolled. The 6-month angiographic and 1-year clinical outcomes were compared among the 3 groups. At 6 months, there was a trend toward a higher incidence of binary restenosis in the PES group (SES: 8.6%, PES: 19.8%, ZES: 8.3%, P=0.052). Percentage of restenosis was higher in the PES group compared with SES, but was similar to ZES (SES: 18.75 +/-18.16%, PES: 29.32 +/-24.16%, ZES: 23.91 +/-17.03%, P=0.006). Late loss was lower in the SES group compared with PES and ZES (SES: 0.44 +/-0.52, PES: 0.83 +/-0.87, ZES: 0.75 +/-0.63, P<0.001). However, clinical outcomes, including mortality, MI, repeat PCI and major adverse cardiac events, were not different among the 3 groups.. The angiographic benefit of SES did not translate into a clinical benefit for up to 1 year in AMI patients. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Logistic Models; Male; Middle Aged; Myocardial Infarction; Odds Ratio; Paclitaxel; Prosthesis Design; Registries; Retrospective Studies; Risk Assessment; Risk Factors; Severity of Illness Index; Sirolimus; Treatment Outcome | 2009 |
A generation 2.5 drug-eluting stent?
Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Humans; Hyperplasia; Myocardial Infarction; Prosthesis Design; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2009 |
Histopathology of clinical coronary restenosis in drug-eluting versus bare metal stents.
To characterize in-stent restenosis after the implantation of sirolimus-eluting stents (SES), paclitaxel-eluting stents (PES), tacrolimus-eluting stents (TES), and zotarolimus-eluting stents (ZES), 25 patients treated with drug-eluting stents (DES; 9 PES, 10 SES, 4 TES, and 2 ZES) and 19 with bare-metal stents (BMS) underwent directional coronary atherectomy for in-stent restenosis 4 to 36 months after implantation. Restenosis after DES implantation was more frequently focal and associated with smaller specimens compared to that after BMS implantation. Light and confocal microscopy were used. Histologic features were similar in DES and BMS. In-stent restenotic lesions were composed mainly of neointima containing proteoglycan-rich smooth muscle cells and fibrolipidic regions. Small inflammatory infiltrates were observed, mostly in patients with unstable angina; CD18- and/or CD3(+) cells were detected in patients with BMS and DES. Different smooth muscle cell phenotypes were observed: synthetic was more frequent with BMS and PES, intermediate with ZES, contractile or intermediate with SES, and contractile with TES. The mean proliferation index was low and comparable among stent types; cyclins B1 and D1 were expressed in all DES. In conclusion, intra-DES and intra-BMS restenotic tissue was composed mainly of smooth muscle cells with different phenotypes, proliferating at a low rate. The different smooth muscle cell phenotypes within the stent types might suggest different mechanisms of restenosis. Topics: Aged; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Muscle, Smooth, Vascular; Paclitaxel; Sirolimus; Tacrolimus; Treatment Outcome | 2009 |
Fracture of zotarolimus-eluting stent after implantation.
Drug-eluting stents were developed and approved for the reduction of in-stent restenosis. However, restenosis still occurs, and stent fracture is suggested as a cause of restenosis after implantation. Although sirolimus-eluting stents are considered to carry a high risk of fracture, the risk is also present with other drug-eluting stents. Herein, we report the case of a 78-year-old woman who received a zotarolimus-eluting stent for a bifurcation lesion of the left anterior descending coronary artery. Ten months later, she underwent coronary angiography due to angina. The angiogram revealed in-stent restenosis, with a grade IV stent fracture. After percutaneous coronary angioplasty, the patient's clinical symptoms improved. Topics: Aged; Angina Pectoris; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Prosthesis Failure; Sirolimus; Treatment Outcome | 2009 |
Angiographic time course of in-stent restenosis with zotarolimus drug-eluting stents.
Topics: Aged; Coated Materials, Biocompatible; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Follow-Up Studies; Humans; Male; Prosthesis Failure; Sirolimus; Stents; Time Factors | 2008 |
Coexistent in-stent restenosis, late incomplete stent apposition and mural thrombus in a zotarolimus-eluting stent.
Drug-eluting stents (DES) have been demonstrated to dramatically reduce the rate of in-stent restenosis (ISR). However, some studies found an increased rate of late incomplete stent apposition (ISA) and late stent thrombosis (ST) in DES compared to traditional bare-metal stents (BMS). Endeavor stent, a new cobalt-alloy DES coated with phosphorylcholine and zotarolimus, has been reported to have a very favorable safety profile with few documented late-acquired ISA and late ST. In the present report, we described an interesting case with coexistent ISR, late ISA and mural thrombus in an Endeavor zotarolimus-eluting stent 8 months after primary percutaneous coronary intervention. Topics: Aged; Angioplasty, Balloon, Coronary; Blood Vessel Prosthesis Implantation; Coronary Angiography; Coronary Restenosis; Drug-Eluting Stents; Heart Diseases; Humans; Immunosuppressive Agents; Male; Myocardial Infarction; Prosthesis Failure; Reoperation; Sirolimus; Thrombosis; Ultrasonography, Interventional | 2008 |
Everolimus- and zotarolimus-eluting stents for bare metal stent in-stent restenosis treatment: a prospective study.
Treatment of in-stent restenosis (ISR) is a challenging clinical problem. Recent studies have verified the safety and efficacy of first-generation DES for the treatment of ISR. The safety and effectiveness of new-generation drug-eluting stents (nDES) for ISR has not been previously investigated. The aim of the present study was to prospectively evaluate the clinical outcomes after treatment with nDES implantation in patients with bare metal stent (BMS) ISR.. Consecutive patients with ISR after BMS implantation were included. Primary end-point was a major adverse cardiac event (MACE), defined as death, myocardial infarction (MI), or target vessel revascularization (TVR). The incidence of stent thrombosis was also evaluated.. A total of 46 consecutive patients were enrolled for the treatment of ISR, 23 patients from ZES and 23 from EES group. There were two (8.7%) cases of TVR in ZES cohort due to proliferative ISR at 6 and 7 months after DES implantation, and none in EES. One (4.3%) patient underwent percutaneous coronary intervention and the other (4.3%) was treated surgically. Neither acute nor subacute thrombosis was observed during the 13.3+/-6.3 months follow-up period. In all other patients, stress test was negative for ischemia at 6 months.. In this prospective study, we showed that direct nDES implantation is highly effective for ISR and seems to be a promising management for the treatment of ISR. Topics: Aged; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Exercise Test; Female; Humans; Immunosuppressive Agents; Ischemia; Male; Middle Aged; Outcome and Process Assessment, Health Care; Prospective Studies; Sirolimus; Stents; Treatment Outcome | 2008 |
Is there a preferable DES in diabetic patients? A critical appraisal of the evidence.
Drug-eluting stent (DES) therapy reduces restenosis in patients with diabetes when compared with bare metal stent implantation. There are significant differences between commercially available DES platforms both in terms of design characteristics and clinical outcomes. Randomized active-comparator inter-DES trials powered for clinical endpoints are unlikely to be performed in patients with diabetes, however, direct comparison randomized trials utilizing surrogate endpoints support a superior anti-restenotic efficacy with sirolimus- versus paclitaxel-eluting stents. Thrombotic stent occlusion may be higher in patients with diabetes compared with nondiabetic patients, though there is no clear signal of a safety differential between the two platforms. Insufficient data on comparative performance in diabetics exist in relation to the approved zotarolimus-eluting and everolimus-eluting stent platforms. If all other factors are equal, then there seems to be no reason why the diabetic patient should not receive treatment with the sirolimus-eluting stent, which appears to have superior antirestenotic efficacy in this patient group. Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Restenosis; Coronary Stenosis; Diabetes Complications; Drug-Eluting Stents; Everolimus; Evidence-Based Medicine; Humans; Hypoglycemic Agents; Insulin; Meta-Analysis as Topic; Metals; Paclitaxel; Patient Selection; Prosthesis Design; Randomized Controlled Trials as Topic; Registries; Risk Assessment; Sirolimus; Thrombosis; Treatment Outcome | 2008 |
Long-term safety and efficacy are observed after implantation of Zotarolimus-Eluting stent in real-world clinical practice.
Zotarolimus-eluting stents (ZESs) have been shown to be safe and effective in randomised trials. We sought to report the clinical outcomes after implantation of ZES in real-world clinical practice.. ZES have been approved for clinical use in Singapore since April 2005. Until December 31, 2007, a total of 219 patients had undergone implantation of ZES. After excluding 11 foreign patients with whom contact was lost, 208 patients (246 lesions, 305 stents) formed the study cohort. A high-proportion of diabetic patients (n=90, 43.3%) was included. Recommended dual antiplatelet therapy was at least 3 months (n=147) for patients treated before or 12 months (n=61) after January 2007. As of January 2008, the median follow-up duration was 19 months (range: 1 to 33 months). There were 10 (4.8%) deaths, including 7 (3.4%) cardiac deaths. Myocardial infarction occurred in 11 (5.3%) patients. The numbers of patients requiring target vessel revascularisation and target lesion revascularisation were 10 (4.8%) and 5 (2.4%) respectively. Using the ARC definition, there were two cases of definite stent thrombosis on days 7 and 17, and one case of probable stent thrombosis on day 15.. In this real-world clinical experience, ZES was associated with a low incidence of adverse cardiac events at a medium follow-up of one and half years. Topics: Aged; Angioplasty, Balloon, Coronary; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Death, Sudden, Cardiac; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Incidence; Inpatients; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Platelet Aggregation Inhibitors; Retrospective Studies; Sirolimus | 2008 |
The process of bringing new drug-eluting stents to market will they see the light of day?
Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Restenosis; Coronary Stenosis; Cost-Benefit Analysis; Drug-Eluting Stents; Humans; Paclitaxel; Prosthesis Design; Randomized Controlled Trials as Topic; Research Design; Risk Assessment; Severity of Illness Index; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2008 |
TCT Daily: ZOMAXX I--mixed results with zotarolimus-eluting stent.
Topics: Angioplasty, Balloon, Coronary; Coronary Restenosis; Coronary Stenosis; Drug Delivery Systems; France; Humans; Immunosuppressive Agents; Randomized Controlled Trials as Topic; Sirolimus; Stents; Treatment Outcome | 2007 |
Do the benefits outweigh the risks with drug-eluting stents?
Topics: Coronary Restenosis; Everolimus; Humans; Paclitaxel; Patient Selection; Platelet Aggregation Inhibitors; Prosthesis Design; Risk Assessment; Sirolimus; Stents; Thrombosis | 2007 |
Late vascular response at the edges of sirolimus analogous-eluting stents in diabetic patients: An intravascular ultrasound study.
Vascular response at edges of drug-eluting stents is still not well established, particularly in diabetic patients who are prone to aggressive atherosclerosis progression. Recently, Biolimus and Zotarolimus have demonstrated potent antiproliferative effects.. To compare the vascular responses at edges of sirolimus analogous-eluting stents in patients with and without diabetes, using intravascular ultrasound (IVUS).. 306 edges were analyzed in 153 patients treated with drug-eluting stents and divided in: diabetics (122 edges) and nondiabetics (166 edges). IVUS was performed postintervention and at 6-month follow-up and included 5 mm distal and proximal to the stented segment. Vessel, lumen, and plaque volumes were calculated. Volume variation (follow-up minus basal) was also calculated. Edge restenosis was defined as obstruction >50%.. Baseline characteristics were similar between groups. In both groups the entire lesion length was covered (stent length/lesion length ratio was 1.5 for both groups). There were no differences in edge volumes and restenosis rate between the groups. Among diabetics, there was no significant volume variation. However, in nondiabetic patients there was significant increase in vessel volume in proximal (from 67.1 +/- 22 mm(3) to 72.2 +/- 25 mm(3): P = 0.02) and distal (from 54.4 +/- 22 mm(3) to 59.8 +/- 22 mm(3): P = 0.001) edges.. Nondiabetic patients showed a significant positive vascular remodeling in proximal and distal edges of sirolimus analogous-eluting stent. This vascular mechanism was not observed in diabetic patients. Although different vascular responses were observed, restenosis rates were equivalent between the 2 groups at 6-month follow-up. Topics: Aged; Cardiovascular Agents; Case-Control Studies; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Diabetic Angiopathies; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome; Ultrasonography, Interventional | 2007 |
Determination of sirolimus in rabbit arteries using liquid chromatography separation and tandem mass spectrometric detection.
Sirolimus, an effective immunosuppressive agent, is used for drug eluting stents. During stent development, an analytical method for the determination of sirolimus in tissue needs to be established. Normally, tissue samples are homogenized and then analyzed against the calibration standards prepared in a tissue homogenate. This approach provides insufficient control of the homogenization process. In this paper, tissue quality control samples were introduced for the optimization of the homogenization process during method development, but also allowance for the performance evaluation of the entire analytical process. In addition, a new approach using rabbit blood as a homogenization medium was developed to stabilize sirolimus in rabbit tissue homogenates. Calibration standards and quality controls were prepared by spiking different sirolimus working solutions into rabbit blood. Homogenization quality control samples were prepared by injecting other sirolimus working solutions into empty test tubes and pre-cut arteries within pre-defined masses. A high-throughput homogenization procedure was optimized based on the specific chemical properties of sirolimus. The linear dynamic range was between 49.9 pg/mL and 31.9 ng/mL to accommodate the expected artery homogenate concentrations. Additionally, quality controls in rabbit blood were also used in the extraction to support the calibration standards. The accuracy and precision of the quality controls in rabbit blood reflect the extraction performance and the accuracy and precision of the homogenization tissue quality controls reflect the overall performance of the method. The mean bias was between -4.5 and 0.2% for all levels of quality controls in the blood and between 4.8 and 14.9% for all levels of the homogenization tissue quality controls. The CVs of all concentration levels were < or =5.3% for the quality controls in blood and < or =9.2% for the homogenization tissue quality controls. The method was successfully applied to determine the concentration of sirolimus in the rabbit arteries. Topics: Animals; Arteries; Chemical Fractionation; Chromatography, High Pressure Liquid; Coronary Restenosis; Drug Monitoring; Drug Stability; Drug-Eluting Stents; Quality Control; Rabbits; Reference Standards; Reproducibility of Results; Sensitivity and Specificity; Sirolimus; Specimen Handling; Spectrometry, Mass, Electrospray Ionization; Tandem Mass Spectrometry; Tissue Distribution | 2007 |
The pros and cons of living on the edge.
Topics: Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Diabetic Angiopathies; Drug-Eluting Stents; Humans; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome; Ultrasonography, Interventional | 2007 |
Zotarolimus-eluting stents reduce experimental coronary artery neointimal hyperplasia after 4 weeks.
The addition of drug elution to coronary stents plays an integral role in coronary restenosis prevention. The present study was undertaken to determine the mechanism of action and the in vitro and in vivo efficacy of zotarolimus, a new chemical entity designed specifically for elution from phosphorylcholine (PC)-coated stents, for the reduction of neointimal hyperplasia in porcine coronary arteries.. In vitro studies of Zotarolimus bound to FKBP-12 potently inhibited smooth muscle cells (SMCs) and endothelial cell (EC) proliferation. Twenty PC-only and 20 stents eluting zotarolimus 10 microg/mm were implanted in the coronary arteries of 20 domestic juvenile swine. After 28 days, zotarolimus stents exhibited less area stenosis (22.4+/-8.6 vs. 35.7+/-13%, P = 0.01), less neointimal area (1.69+/-0.55 vs. 2.78+/-1.07 mm(2), P = 0.01), less neointimal thickness (0.25+/-0.07 vs. 0.38+/-0.13 mm, P = 0.01), and greater lumen area (6.07+/-1.39 vs. 5.02+/-1.3 mm2, P = 0.01). All arteries in both the polymer-only and polymer/drug stent showed near-complete healing and minimal toxicity. Zotarolimus did not affect the extrastent segments nor alter the overall artery size (external elastic lamina cross-sectional area 9.18+/-1.19 vs. 9.06+/-1.28 mm2, P = 0.7).. Zotarolimus binds to FKBP-12 and in vitro inhibits SMC and EC proliferation. Zotarolimus applied to PC-coated stents reduces neointima in the swine coronary model after 28 days. These results suggest potentially promising human clinical application for coronary stenting with this polymer/drug combination. Topics: Animals; Coronary Restenosis; Coronary Vessels; Drug Implants; Hyperplasia; Immunosuppressive Agents; Sirolimus; Stents; Swine; Tunica Intima | 2006 |