umirolimus and Thrombosis

umirolimus has been researched along with Thrombosis* in 21 studies

Reviews

4 review(s) available for umirolimus and Thrombosis

ArticleYear
A mixed treatment comparison for short- and long-term outcomes of bare-metal and drug-eluting coronary stents.
    International journal of cardiology, 2016, Jan-01, Volume: 202

    The increasing use of drug eluting stents in interventional cardiology calls for assessment of their efficacy and safety, both among drug-eluting and bare-metal stents, in the context of rational decision making.. We searched for papers that compared any of the sirolimus-eluting stent, paclitaxel-eluting stent, drug- eluting stent, biodegradable stent, everolimus-eluting stent, zotarolimus-resolute eluting stent, biolimus- eluting stent, bare-metal stent and zotarolimus-eluting stent. The search was contacted through Medline, the Cochrane database, Embase, TCTMD, ClinicalTrials.gov, Clinical Trial Results, CardioSource, abstracts and presentations from major cardiovascular meetings. We also searched for further articles cited by selected papers. Furthermore, important conferences and relevant proceedings and abstracts, such as the American Heart Association, American College of Cardiology, Transcatheter Cardiovascular Therapeutics, Society of Cardiovascular Angiography and Intervention, European Society of Cardiology, and Euro-PCR, were also searched. Inclusion criteria were: randomised controlled trials (RCTs), size of study (≥100 patients), duration more than 6 months and definition of reported endpoints (target vessel revascularization, thrombosis, myocardial infarction and cardiac death). Analysis of the data was performed for short-term (less than a year) and long-term outcomes (more than a year). A mixed treatment comparison approach was utilised for the data analysis.. Based on the rankings of each treatment, a distinct difference between the 2nd and 1st generation stents was identified. We can conclude that everolimus, zotarolimus-resolute and biolimus eluting stents carry the highest probabilities of being superior for all endpoints.

    Topics: Aged; Aged, 80 and over; Antineoplastic Agents, Phytogenic; Death; Drug-Eluting Stents; Everolimus; Humans; Immunosuppressive Agents; Male; Metals; Middle Aged; Myocardial Infarction; Paclitaxel; Percutaneous Coronary Intervention; Randomized Controlled Trials as Topic; Sirolimus; Stents; Thrombosis; Treatment Outcome

2016
Long-term outcomes of biodegradable polymer versus durable polymer drug-eluting stents in patients with diabetes a pooled analysis of individual patient data from 3 randomized trials.
    International journal of cardiology, 2013, Oct-15, Volume: 168, Issue:6

    There is ongoing debate on the optimal drug-eluting stent (DES) in diabetic patients with coronary artery disease. Biodegradable polymer drug-eluting stents (BP-DES) may potentially improve clinical outcomes in these high-risk patients. We sought to compare long-term outcomes in patients with diabetes treated with biodegradable polymer DES vs. durable polymer sirolimus-eluting stents (SES).. We pooled individual patient-level data from 3 randomized clinical trials (ISAR-TEST 3, ISAR-TEST 4 and LEADERS) comparing biodegradable polymer DES with durable polymer SES. Clinical outcomes out to 4 years were assessed. The primary end point was the composite of cardiac death, myocardial infarction and target-lesion revascularization. Secondary end points were target lesion revascularization and definite or probable stent thrombosis.. Of 1094 patients with diabetes included in the present analysis, 657 received biodegradable polymer DES and 437 durable polymer SES. At 4 years, the incidence of the primary end point was similar with BP-DES versus SES (hazard ratio = 0.95, 95% CI = 0.74-1.21, P = 0.67). Target lesion revascularization was also comparable between the groups (hazard ratio = 0.89, 95% CI = 0.65-1.22, P = 0.47). Definite or probable stent thrombosis was significantly reduced among patients treated with BP-DES (hazard ratio = 0.52, 95% CI = 0.28-0.96, P = 0.04), a difference driven by significantly lower stent thrombosis rates with BP-DES between 1 and 4 years (hazard ratio = 0.15, 95% CI = 0.03-0.70, P = 0.02).. In patients with diabetes, biodegradable polymer DES, compared to durable polymer SES, were associated with comparable overall clinical outcomes during follow-up to 4 years. Rates of stent thrombosis were significantly lower with BP-DES.

    Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Coronary Artery Disease; Diabetes Complications; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Multicenter Studies as Topic; Polymers; Randomized Controlled Trials as Topic; Risk Assessment; Sirolimus; Thrombosis; Treatment Outcome

2013
[Types and characteristic features of drug-eluting stents].
    Nihon rinsho. Japanese journal of clinical medicine, 2011, Volume: 69, Issue:2

    Types and characteristics of current-available drug-eluting stents(DES) are introduced in this review. Currently, DESs with agents of "limus family" are mainly used because of their efficacy and safety. Two representative performances, angiographic late loss and incidence of late acquired incomplete stent apposition, are compared between these DESs. Furthermore, patient-to-patient variation in amount of neointimal hyperplasia, which is chiefly associated with clinical outcomes, tends to be larger for the DES with larger average angiographic late loss. Thrombotic complications are unexpectedly more frequent in the DES with larger late loss within first one year according to the randomized clinical trials, however, persistent influences to vascular wall become dominant factors stent thrombosis at very late phases.

    Topics: Angioplasty, Balloon, Coronary; Antineoplastic Agents; Drug-Eluting Stents; Everolimus; Paclitaxel; Randomized Controlled Trials as Topic; Sirolimus; Thrombosis

2011
Drug-eluting stents - what should be improved?
    Annals of medicine, 2008, Volume: 40, Issue:4

    Despite the success of drug-eluting stents (DES) in reducing restenosis and the need for target vessel revascularization, several deficiencies have been unraveled since their first clinical application including the risk of stent thrombosis, undesired effects due to the stent polymer as well as the stent itself, and incomplete inhibition of restenosis (especially in complex lesions). Several novel stent systems are being investigated in order to address these issues. In second-generation DES, the rapamycin analogues zotarolimus and everolimus (and more recently biolimus) have been most extensively studied. Furthermore, special stent-coatings to actively promote endothelial healing (in order to reduce the risk of stent thrombosis) and to further reduce restenosis have been employed. To avoid undesirable effects of currently applied (durable) polymers, biocompatible and bioabsorbable polymers as well as DES delivery systems without the need for a polymer have been developed. Bioabsorbable stents, both polymeric and metallic, were developed to decrease potential late complications after stent implantation. Although most of these innovative novel principles intuitively seem appealing and demonstrate good results in initial clinical evaluations, long-term large-scale studies are necessary in order to reliably assess whether these novel systems are truly superior to first-generation DES with respect to safety and efficacy.

    Topics: Coated Materials, Biocompatible; Coronary Restenosis; Coronary Vessels; Drug Delivery Systems; Drug-Eluting Stents; Everolimus; Humans; Polymers; Sirolimus; Thrombosis

2008

Trials

9 trial(s) available for umirolimus and Thrombosis

ArticleYear
Comparison of biolimus A9-eluting (Nobori) and everolimus-eluting (Promus Element) stents in patients with de novo native long coronary artery lesions: a randomized Long Drug-Eluting Stent V trial.
    Circulation. Cardiovascular interventions, 2014, Volume: 7, Issue:3

    Procedural and clinical outcomes still remain unfavorable for patients with long coronary lesions who undergo percutaneous coronary intervention. The current study, therefore, evaluated 2 innovative drug-eluting stents for the management of long-lesion coronary artery disease.. This randomized, multicenter, prospective trial, called the Long Drug-Eluting Stent (LONG-DES) V trial, compared the biodegradable polymer-based biolimus A9-eluting stent (BES) and the durable polymer-based platinum chromium everolimus-eluting stent (PtCr-EES) in 500 patients with long (≥ 25 mm) coronary lesions. The primary end point of the trial was in-segment late luminal loss at the 9-month angiographic follow-up. The BES and PtCr-EES groups had similar baseline characteristics, with a slightly shorter lesion length in the BES group versus the PtCr-EES group (29.24 ± 12.17 versus 32.27 ± 13.84 mm; P = 0.016). In-segment late luminal loss was comparable between the 2 groups at the 9-month angiographic follow-up (BES, 0.14 ± 0.38 versus PtCr-EES, 0.11 ± 0.37 mm; difference, 0.031; 95% confidence interval, -0.053 to 0.091; P = 0.03 for a noninferiority margin of 0.11, P = 0.45 for superiority), as was in-stent late luminal loss (0.20 ± 0.41 versus 0.24 ± 0.38 mm; P = 0.29). The incidence of in-segment (6.1% versus 4.9%; P = 0.63) and in-stent (3.7% versus 4.9%; P = 0.59) binary restenosis was also similar between the groups. There was no significant between-group difference in the rate of composite outcome of death, myocardial infarction, and target vessel revascularization (41, 16.7% in BES versus 42, 16.5% in PtCr-EES; P=0.94).. BES and PtCr-EES implantation showed analogous angiographic and clinical outcomes for patients with de novo long coronary lesions.. http://www.clinicaltrials.gov. Unique identifier: NCT01186120.

    Topics: Aged; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Incidence; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Single-Blind Method; Sirolimus; Survival Rate; Thrombosis; Treatment Outcome

2014
2-year clinical follow-up from the randomized comparison of biolimus-eluting stents with biodegradable polymer and sirolimus-eluting stents with durable polymer in routine clinical practice.
    JACC. Cardiovascular interventions, 2011, Volume: 4, Issue:8

    This study sought to investigate safety and efficacy of biolimus-eluting stents (BES) with biodegradable polymer as compared with sirolimus-eluting stents (SES) with durable polymer through 2 years of follow-up.. BES with a biodegradable polymer provide similar efficacy and safety as SES with a durable polymer at 9 months. Clinical outcomes beyond the period of biodegradation of the polymer used for drug release and after discontinuation of dual antiplatelet therapy are of particular interest.. A total of 1,707 patients were randomized to unrestricted use of BES (n = 857) or SES (n = 850) in an all-comers patient population.. At 2 years, BES remained noninferior compared with SES for the primary endpoint, which was a composite of cardiac death, myocardial infarction, or clinically indicated target vessel revascularization (BES 12.8% vs. SES 15.2%, hazard ratio [HR]: 0.84, 95% confidence interval [CI]: 0.65 to 1.08, p(noninferiority) < 0.0001, p(superiority) = 0.18). Rates of cardiac death (3.2% vs. 3.9%, HR: 0.81, 95% CI: 0.49 to 1.35, p = 0.42), myocardial infarction (6.3% vs. 5.6%, HR: 1.12, 95% CI: 0.76 to 1.65, p = 0.56), and clinically indicated target vessel revascularization (7.5% vs. 8.6%, HR: 0.86, 95% CI: 0.62 to 1.20, p = 0.38) were similar for BES and SES. The rate of definite stent thrombosis through 2 years was 2.2% for BES and 2.5% for SES (p = 0.73). For the period between 1 and 2 years, event rates for definite stent thrombosis were 0.2% for BES and 0.5% for SES (p = 0.42). After discontinuation of dual antiplatelet therapy, no very late definite stent thrombosis occurred in the BES group.. At 2 years of follow-up, the unrestricted use of BES with a biodegradable polymer maintained a similar safety and efficacy profile as SES with a durable polymer. (Limus Eluted From a Durable Versus Erodable Stent Coating [LEADERS]; NCT00389220).

    Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chi-Square Distribution; Coronary Angiography; Coronary Artery Disease; Drug Therapy, Combination; Drug-Eluting Stents; Europe; Female; Follow-Up Studies; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Platelet Aggregation Inhibitors; Proportional Hazards Models; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Survival Rate; Thrombosis; Time Factors; Treatment Outcome

2011
Implantation of the biodegradable polymer biolimus-eluting stent in patients with high SYNTAX score is associated with decreased cardiac mortality compared to a permanent polymer sirolimus-eluting stent: two year follow-up results from the "all-comers" LE
    EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 2011, Volume: 7, Issue:5

    The SYNTAX score (SXscore) has been shown to be an effective predictor of clinical outcomes in patients undergoing percutaneous coronary intervention (PCI).. The SXscore was prospectively collected in 1,397 of the 1,707 patients enrolled in the "all-comers" LEADERS trial (patients post-surgical revascularisation were excluded). Post hoc analysis was performed by stratifying clinical outcomes at two-year follow-up, according to one of three SXscore tertiles: SXlow ≤8 (n=464), 816 (n=461). At two-year follow-up the rate of major adverse cardiovascular events was 18.4%, 12.0% and 9.4% in the SXhigh, SXmid, and SXlow tertile, respectively (HR 1.45; CI 1.21-1.74; p<0.01). There was a significantly higher rate of cardiac death in patients in the highest SXscore tertile (7% SXhigh versus 2.4% SXmid versus 1.8% SXlow; HR 2.22; CI 1.5-3.27; p<0.001). Within the SXhigh tertile the rate of cardiac death was significantly lower in patients treated with the biolimus-eluting stent compared with the sirolimus-eluting stent (4.7% versus 9.6%, HR 0.48; CI 0.23-0.99; p=0.046).. The SXscore when applied to an "all-comers" patient population allows for prospective risk stratification of patients undergoing PCI up to two years follow-up. In addition, the SXscore appears to separate the performance of devices in high risk patient groups.

    Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Heart Diseases; Humans; Male; Middle Aged; Polymers; Proportional Hazards Models; Prospective Studies; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Thrombosis; Time Factors; Tomography, Optical Coherence; Treatment Outcome

2011
The three year follow-up of the randomised "all-comers" trial of a biodegradable polymer biolimus-eluting stent versus permanent polymer sirolimus-eluting stent (LEADERS).
    EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 2011, Volume: 7, Issue:7

    The current study reports clinical outcomes at three year follow-up of the LEADERS clinical trial which was the first all-comers trial comparing a new generation biodegradable polymer biolimus drug-eluting stent (BES) with the first generation permanent polymer sirolimus-eluting stent (SES).. One thousand seven hundred and seven patients were randomised to unrestricted use of BES (n=857) or SES (n=850) in an all-comers population. Three year follow-up was available in 95% of the patients, 812 treated with BES and 809 treated with SES. At three years, BES remains non-inferior to SES for the primary endpoint of major adverse cardiac events (composite of cardiac death, myocardial infarction (MI), or clinically-indicated target vessel revascularisation (CI-TVR) (BES 15.7% versus SES 19%; HR 0.82 CI 0.65-1.03; p=0.09). The MACE Kaplan Meier event curves increasingly diverge with the difference in events increasing from 1.4% to 2.4% and 3.3% at 1, 2 and 3 years, respectively in favour of BES. The rate of cardiac death was non-significantly lower 4.2% versus 5.2% (HR=0.81 CI 0.52-1.26; p=0.34) and the rate of myocardial infarction was equivalent 7.2% versus 7.1% (HR 1.01 CI 0.70-1.44; p=0.97) for BES versus SES, respectively. Thus BES was non-inferior to SES in all the safety endpoints. Clinically-indicated TVR occurred in 9.4% of BES treated patients versus 11.1% of SES treated patients (HR 0.84 CI 0.62-1.13; p=0.25). Rates of definite stent thrombosis were 2.2% for BES and 2.9% for SES (HR 0.78 CI 0.43-1.43; p=0.43), with the event rate increase of 0.2% from one to three years for BES and 0.9% for SES. For patients presenting with ST-elevation myocardial infarction BES was superior to SES in reducing MACE.. The findings of the three year follow-up support the claim that the biodegradable polymer biolimus-eluting stent has equivalent safety and efficacy to permanent polymer sirolimus-eluting stent in an all-comers patient population. Its performance is superior in some subpopulations such as in ST-elevation MI patients and event rates for BES are overall lower than for SES with a trend toward increasing divergence of outcomes over three years.

    Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chi-Square Distribution; Coronary Artery Disease; Drug Therapy, Combination; Drug-Eluting Stents; Europe; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Platelet Aggregation Inhibitors; Polymers; Proportional Hazards Models; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Thrombosis; Time Factors; Treatment Outcome

2011
Long-term clinical outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer sirolimus-eluting stents in patients with coronary artery disease (LEADERS): 4 year follow-up of a randomised non-inferiority trial.
    Lancet (London, England), 2011, Dec-03, Volume: 378, Issue:9807

    The effectiveness of durable polymer drug-eluting stents comes at the expense of delayed arterial healing and subsequent late adverse events such as stent thrombosis (ST). We report the 4 year follow-up of an assessment of biodegradable polymer-based drug-eluting stents, which aim to improve safety by avoiding the persistent inflammatory stimulus of durable polymers.. We did a multicentre, assessor-masked, non-inferiority trial. Between Nov 27, 2006, and May 18, 2007, patients aged 18 years or older with coronary artery disease were randomly allocated with a computer-generated sequence to receive either biodegradable polymer biolimus-eluting stents (BES) or durable polymer sirolimus-eluting stents (SES; 1:1 ratio). The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation (TVR); patients were followed-up for 4 years. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00389220.. 1707 patients with 2472 lesions were randomly allocated to receive either biodegradable polymer BES (857 patients, 1257 lesions) or durable polymer SES (850 patients, 1215 lesions). At 4 years, biodegradable polymer BES were non-inferior to durable polymer SES for the primary endpoint: 160 (18·7%) patients versus 192 (22·6%) patients (rate ratios [RR] 0·81, 95% CI 0·66-1·00, p for non-inferiority <0·0001, p for superiority=0·050). The RR of definite ST was 0·62 (0·35-1·08, p=0·09), which was largely attributable to a lower risk of very late definite ST between years 1 and 4 in the BES group than in the SES group (RR 0·20, 95% CI 0·06-0·67, p=0·004). Conversely, the RR of definite ST during the first year was 0·99 (0·51-1·95; p=0·98) and the test for interaction between RR of definite ST and time was positive (p(interaction)=0·017). We recorded an interaction with time for events associated with ST but not for other events. For primary endpoint events associated with ST, the RR was 0·86 (0·41-1·80) during the first year and 0·17 (0·04-0·78) during subsequent years (p(interaction)=0·049).. Biodegradable polymer BES are non-inferior to durable polymer SES and, by reducing the risk of cardiac events associated with very late ST, might improve long-term clinical outcomes for up to 4 years compared with durable polymer SES.. Biosensors Europe SA, Switzerland.

    Topics: Absorbable Implants; Coronary Artery Disease; Drug-Eluting Stents; Follow-Up Studies; Humans; Polymers; Sirolimus; Thrombosis

2011
Biolimus-eluting biodegradable polymer versus sirolimus-eluting permanent polymer stent performance in long lesions: results from the LEADERS multicentre trial substudy.
    EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 2009, Volume: 5, Issue:3

    Lesion length remains a predictor of target lesion revascularisation and results of long lesion stenting remain poor. Sirolimus-eluting stents have been shown to perform better than paclitaxel eluting stents in long lesions. In this substudy of the LEADERS trial, we compared the performance of biolimus biodegradable polymer (BES) and sirolimus permanent polymer stents (SES) in long lesions.. A total of 1,707 'all-comer' patients were randomly allocated to treatment with BES and SES. A stratified analysis of angiographic and clinical outcomes at nine months and one year, respectively was performed for vessels with lesion length <20 mm versus >20 mm (as measured by quantitative angiography).Of 1,707 patients, 592 BES patients with 831 lesions and 619 SES patients with 876 lesions had only short lesions treated. One hundred and fifty-three BES patients with 166 lesions and 151 SES patients with 162 lesions had long lesions. There were no significant differences in baseline clinical characteristics, except for higher number of patients with long lesions presenting with acute myocardial infarction in both stent groups. Long lesions tended to have lower MLD and greater percent diameter stenosis at baseline than short lesions. Late loss was greater for long lesions than short lesions. There was no statistically significant difference in late loss between BES and SES stents (0.32+/-0.69 vs 0.24+/-0.57, p=0.59). Binary in-segment restenosis was present in 23.2% versus 13.1% of long lesions treated with BES and SES, respectively (p=0.042). In patients with long lesions, the overall MACE rate was similar for BES and SES (17% vs 14.6%; p=0.62). There was a trend towards higher overall TLR rate with BES (12.4 % vs 6.0%; HR=2.06; p=0.07) and clinically driven TLR (10.5% vs 5.3%: HR 1.94; p=0.13). Rates of definite stent thrombosis were 3.3% in the long lesion group and 1.3-1.7 % in the short lesion group.. BES and SES appear similar with respect to MACE in long lesions in this "all-comer" patient population. However, long lesions tended to have a higher rate of binary in-segment restenosis and TLR following BES than SES treatment.

    Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Europe; Female; Humans; Male; Middle Aged; Myocardial Infarction; Polymers; Proportional Hazards Models; Prosthesis Design; Risk Assessment; Sirolimus; Thrombosis; Time Factors; Treatment Outcome

2009
Impact of vessel size on angiographic and clinical outcomes of revascularization with biolimus-eluting stent with biodegradable polymer and sirolimus-eluting stent with durable polymer the LEADERS trial substudy.
    JACC. Cardiovascular interventions, 2009, Volume: 2, Issue:9

    We assessed the impact of vessel size on outcomes of stenting with biolimus-eluting degradable polymer stent (BES) and sirolimus-eluting permanent polymer stent (SES) within a randomized multicenter trial (LEADERS).. Stenting of small vessels might be associated with higher rates of adverse events.. "All-comer" patients (n = 1,707) were randomized to BES and SES. Post-hoc-stratified analysis of angiographic and clinical outcomes at 9 months and 1 year, respectively, was performed for vessels with reference diameter 2.75 mm.. Of 1,707 patients, 429 patients in the BES group with 576 lesions and 434 patients in the SES group with 557 lesions had only small vessels treated (50.6% of the patient cohort). In patients with small vessels there was no significant difference in overall major adverse cardiac events (MACE) rate (12.1% vs. 11.8%; p = 0.89) or target lesion revascularization (TLR) rate (9.6% vs. 7.4%; p = 0.26) between BES and SES. The MACE and TLR rates in the small-vessel patient population were higher than in the large-vessel population. The TLR rate was 9.6% versus 2.6%, and MACE rate was 12.1% versus 7.1% for small versus large vessels in the BES arm (TLR: hazard ratio [HR] = 3.724, p = 0.0013; MACE: HR = 1.720, p = 0.0412). In the SES arm, TLR was 7.4% versus 5.1%, and MACE was 11.8% versus 10.3% in small versus large vessels (TLR: HR = 1.435, p = 0.2594; MACE: HR = 1.149, p = 0.5546).. Prevalence of small vessel disease is high in an "all-comer" population with higher TLR and MACE rates. The BES and SES seem equivalent in treatment outcomes of small vessels in this "all-comer" patient population.

    Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Europe; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Polymers; Proportional Hazards Models; Prosthesis Design; Risk Assessment; Severity of Illness Index; Sirolimus; Thrombosis; Time Factors; Treatment Outcome

2009
Randomized comparison of the Nobori Biolimus A9-eluting coronary stent with the Taxus Liberté paclitaxel-eluting coronary stent in patients with stenosis in native coronary arteries: the NOBORI 1 trial--Phase 2.
    Circulation. Cardiovascular interventions, 2009, Volume: 2, Issue:3

    The newly developed Nobori coronary stent coated with a bioresorbable polymer, polylactic acid, and the antiproliferative agent Biolimus A9 has the potential to reduce restenosis by suppressing neointima formation.. We conducted a randomized (2:1), controlled trial comparing the Biolimus A9-eluting stent Nobori and the paclitaxel-eluting stent Taxus Liberté, in 243 patients (153 Nobori and 90 Taxus) at 29 centers in Europe, Asia, and Australia. Patients with previously untreated lesions in up to 2 native coronary arteries were considered for enrollment. The primary end point was in-stent late loss at 9 months, whereas secondary end points included other quantitative coronary angiography parameters, such as in-segment late loss and the rate of restenosis as well as key intravascular ultrasound parameters. Clinical secondary end points were stent thrombosis and composite of major adverse cardiac events comprising death, myocardial infarction, and target vessel revascularization. At 9 months, the in-stent late loss was significantly lower in the Nobori group compared with the Taxus group (0.11+/-0.30 mm versus 0.32+/-0.50 mm) reaching both the primary hypothesis of noninferiority of Nobori stent versus Taxus Liberté stent (P<0.001) and the secondary hypothesis of superiority (P=0.001). This finding was confirmed by a significant reduction in binary restenosis from 6.2% in Taxus to 0.7% in Nobori (P=0.02) and neointimal volume obstruction, detected by intravascular ultrasound, from 5.5+/-7.2% in Taxus to 1.8+/-5.2% in Nobori (P=0.01). The major adverse cardiac events rate was 4.6% in the Nobori and 5.6% in the Taxus cohort of patients. The stent thrombosis rate was 0% in the Nobori arm and 4.4% in the Taxus arm.. The NOBORI 1 clinical trial confirmed its primary hypothesis--noninferiority of the Nobori Biolimus A9-eluting stent versus the Taxus Liberté stent in reducing neointimal proliferation. Both stents showed a low major adverse cardiac events rate in the studied population.

    Topics: Angioplasty, Balloon, Coronary; Asia; Australia; Cardiovascular Agents; Cell Proliferation; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Coronary Vessels; Drug-Eluting Stents; Europe; Female; Humans; Hyperplasia; Male; Middle Aged; Myocardial Infarction; Paclitaxel; Prospective Studies; Risk Assessment; Sirolimus; Thrombosis; Time Factors; Treatment Outcome; Ultrasonography, Interventional

2009
Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): a randomised non-inferiority trial.
    Lancet (London, England), 2008, Sep-27, Volume: 372, Issue:9644

    A novel stent platform eluting biolimus, a sirolimus analogue, from a biodegradable polymer showed promising results in preliminary studies. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with a sirolimus-eluting stent (with durable polymer).. We undertook a multicentre, assessor-blind, non-inferiority study in ten European centres. 1707 patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes were centrally randomised by a computer-generated allocation sequence to treatment with either biolimus-eluting (n=857) or sirolimus-eluting (n=850) stents. The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation within 9 months. Analysis was by intention to treat. 427 patients were randomly allocated to angiographic follow-up, with in-stent percentage diameter stenosis as principal outcome measure at 9 months. The trial is registered with ClinicalTrials.gov, number NCT00389220.. We analysed all randomised patients. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents for the primary endpoint at 9 months (79 [9%] patients vs 89 [11%], rate ratio 0.88 [95% CI 0.64-1.19], p for non-inferiority=0.003, p for superiority=0.39). Frequency of cardiac death (14 [1.6%] vs 21 [2.5%], p for superiority=0.22), myocardial infarction (49 [5.7%] vs 39 [4.6%], p=0.30), and clinically-indicated target vessel revascularisation (38 [4.4%] vs 47 [5.5%], p=0.29) were similar for both stent types. 168 (79%) patients in the biolimus-eluting group and 167 (78%) in the sirolimus-eluting group had data for angiographic follow-up available. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents in in-stent percentage diameter stenosis (20.9%vs 23.3%, difference -2.2% [95% CI -6.0 to 1.6], p for non-inferiority=0.001, p for superiority=0.26).. Our results suggest that a stent eluting biolimus from a biodegradable polymer represents a safe and effective alternative to a stent eluting sirolimus from a durable polymer in patients with chronic stable coronary artery disease or acute coronary syndromes.. Biosensors Europe SA, Switzerland.

    Topics: Absorbable Implants; Aged; Biocompatible Materials; Chronic Disease; Coronary Disease; Drug-Eluting Stents; Female; Humans; Male; Materials Testing; Metals; Middle Aged; Polymers; Sirolimus; Thrombosis; Treatment Outcome

2008

Other Studies

8 other study(ies) available for umirolimus and Thrombosis

ArticleYear
Polymer-free biolimus-A9-eluting stent performance according to renal impairment: insights from the RUDI-FREE registry.
    Journal of cardiovascular medicine (Hagerstown, Md.), 2022, 02-01, Volume: 23, Issue:2

    Patients with chronic kidney disease (CKD) are at increased risk of cardiovascular disease and have a worse prognosis after percutaneous coronary interventions (PCI). The BioFreedom polymer-free biolimus-A9-eluting stent (PF-BES) has shown promising results in patients at high bleeding risk; however, its performance in CKD patients has yet to be analyzed.. The all-comers RUDI-FREE registry documented patients undergoing PCI with PF-BES in routine clinical practice. Patients were stratified into three groups according to their estimated glomerular filtration rate (eGFR): preserved renal function, mild renal insufficiency (RI), and with moderate to severe RI (eGFR ≥ 90, between 90 and 45, and <45 ml/min/1.73 m2, respectively). The primary safety end point was a patient-oriented composite end point of cardiovascular death, myocardial infarction (MI), and definite or probable stent thrombosis (ST). The primary efficacy end point was target lesion revascularization (TLR).. The registry documented 1,104 consecutive patients treated with PF-BES: 258 (23.4%) with preserved renal function, whereas 712 (64.7%) and 131 (11.9%) had mild and moderate to severe RI, respectively. At 1 year, the primary safety end point was significantly higher in patients with moderate to severe RI (3.5% vs. 2.8% vs. 11.5%; P < 0.001). Conversely, TLR proved similar among groups (0.4% vs. 1.8% vs. 0.8%; P = 0.235).. Patients with worse renal function had increased risk of the composite of cardiovascular deaths, MI, and definite or probable ST. However, the PF-BES showed similar efficacy despite differences in renal function. These findings need to be confirmed in large-scale randomized trials.

    Topics: Aged; Cardiovascular Diseases; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Registries; Renal Insufficiency, Chronic; Sirolimus; Thrombosis

2022
Comparison of 1-Month and 12-Month Vessel Responses Between the Polymer-Free Biolimus A9-Coated Stent and the Durable Polymer Everolimus-Eluting Stent.
    Circulation journal : official journal of the Japanese Circulation Society, 2022, 08-25, Volume: 86, Issue:9

    A polymer-free biolimus A9-coated stent (PF-BCS) may achieve better arterial healing than a durable polymer drug-eluting stent owing to its polymer-free feature.Methods and Results: This multicenter, prospective, observational study enrolled 105 patients (132 lesions) who underwent PF-BCS (51 patients, 71 lesions) or durable polymer everolimus-eluting stent (DP-EES, 54 patients, 61 lesions) implantation. Serial coronary angioscopy (CAS) and optical coherence tomography (OCT) examinations were performed at 1 and 12 months, and the serial vessel responses were compared between PF-BCS and DP-EES. The primary outcome measure was the incidence of subclinical intrastent thrombus on CAS. The secondary outcome measures were: adequate strut coverage (≥40 μm) on OCT and maximum yellow color grade on CAS. The incidence of thrombus was high at 1 month (100% vs. 93%, P=0.091), but decreased at 12 months (18% vs. 25%, P=0.56), without a significant difference between PF-BCS and DP-EES. The adequate strut coverage rate was significantly higher (84±14% vs. 69±22%, P<0.001) and yellow color was significantly less intense (P=0.012) at 12 months in PF-BCS than in DP-EES; however, they were not significantly different at 1 month (adequate strut coverage: 47±21% vs. 50±17%, P=0.40; yellow color: P=0.99).. Although the thrombogenicity of PF-BCS was similar to that of DP-EES, the adequate coverage and plaque stabilization rates of PF-BCS were superior to those of DP-EES at 12 months.

    Topics: Absorbable Implants; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Humans; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Prosthesis Design; Sirolimus; Thrombosis; Treatment Outcome

2022
Clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents versus durable polymer everolimus-eluting Xience stents.
    PloS one, 2017, Volume: 12, Issue:8

    There are limited data about clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents (BP-BES) and durable polymer everolimus-eluting Xience stents (DP-EES) in real world practice. We sought to compare the clinical outcomes of BP-BES and DP-EES in real world cohorts of patients undergoing percutaneous coronary intervention. A prospective multicenter registry enrolled 999 patients treated with BP-BES and 1,000 patients treated with DP-EES. The primary outcome was target lesion failure, defined as a composite of cardiac death, target vessel-related myocardial infarction, or target lesion revascularization. Definite or probable stent thrombosis was also compared in total and propensity score-matched cohorts. The median follow-up duration was 24 months, and mean age was 65 years (interquartile range, 56-72 years). Patients receiving BP-BES had a lower prevalence of acute coronary syndrome, prior myocardial infarction, multi-vessel disease, bifurcation lesions, and left anterior descending artery lesions than those receiving DP-EES. After propensity score matching (692 pairs), target lesion failure occurred in 22 patients receiving BP-BES and in 25 patients receiving DP-EES (3.2% versus 3.6%; adjusted hazard ratio [HR], 0.92; 95% confidence interval [CI], 0.53 to 1.60; p = 0.77). The risk of definite or probable stent thrombosis did not differ between the 2 groups (0.4% versus 0.4%; adjusted HR, 1.03; 95% CI, 0.21 to 4.98; p = 0.97). The results were consistent across various subgroups. In the propensity score-matched analysis of real world cohorts, BP-BES showed similar clinical outcomes compared to DP-EES. We need to investigate about whether differences in clinical outcome emerge during long-term follow-up.

    Topics: Absorbable Implants; Aged; Coated Materials, Biocompatible; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Propensity Score; Proportional Hazards Models; Prospective Studies; Sirolimus; Thrombosis; Treatment Outcome

2017
Comparison of First- and Second-Generation Drug-Eluting Stents in an All-Comer Population of Patients with Diabetes Mellitus (from Katowice-Zabrze Registry).
    Medical science monitor : international medical journal of experimental and clinical research, 2015, Oct-27, Volume: 21

    This study compared safety and efficacy of first- and second-generation DES in an unrestricted, real-life population of diabetic patients undergoing PCI.. The study was a subanalysis of diabetic patients from the all-comer Katowice-Zabrze Registry of patients undergoing PCI with the implantation of either first- (Paclitaxel-, Sirolimus-eluting stents) or second-generation DES (Zotarolimus-, Everolimus-, Biolimus-eluting stents). Efficacy defined as major adverse cardiac and cerebrovascular events (MACCE: death, myocardial infarction, target vessel revascularization, stroke) and safety defined as stent thrombosis (ST) were evaluated at 1 year.. From the total of 1916 patients, 717 were diabetics. Among them, 257 (36%) were treated with first-generation DES (230 [89%] Paclitaxel-eluting stents, 27 [11%] Sirolimus-eluting stents), 460 with second-generation DES (171 [37%] Zotarolimus-eluting stents, 243 [53%] Everolimus-eluting stents, 46 [10%] Biolimus-eluting stents). Rate of MACCE was equal in both groups (p=0.54). Second-generation DES had a better safety profile than first-generation DES (log-rank for cumulative ST at 1 year p<0.001). First-generation DES was a risk factor for ST (HR 5.75 [1.16-28.47], p=0.03) but not for MACCE (HR 0.89 [0.6-1.32], p=0.57).. In a real-life setting of diabetic patients undergoing PCI, second-generation DES had lower risk of ST and similar MACCE rate compared to first-generation DES.

    Topics: Aged; Angiography; Coronary Stenosis; Diabetes Mellitus; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Myocardial Revascularization; Paclitaxel; Percutaneous Coronary Intervention; Poland; Proportional Hazards Models; Registries; Retrospective Studies; Sirolimus; Stents; Thrombosis; Treatment Outcome

2015
New-generation drug-eluting stent experience in the percutaneous treatment of unprotected left main coronary artery disease: the NEST registry.
    The Journal of invasive cardiology, 2013, Volume: 25, Issue:6

    To explore the 2-year clinical outcomes in patients with unprotected left main coronary artery (ULMCA) disease treated with overall new drug-eluting stent (DES) options.. Recent available data have shown the feasibility and the safety of new DESs, mainly evaluating the everolimus-eluting stents in the setting of ULMCA disease.. Patients with ULMCA disease undergoing percutaneous coronary intervention (PCI) with everolimus-, zotarolimus-, and biolimus A9-eluting stents were prospectively evaluated. The study objective was the composite of major adverse cardiac events (MACEs), consisting of all-cause mortality, myocardial infarction (MI), and target vessel revascularization (TVR) at 2-year clinical follow-up.. A total of 154 patients were analyzed. The mean EuroSCORE and SYNTAX scores were 4.7 ± 2.6 and 27.5 ± 8.3, respectively. Distal location was present in 126 patients (81.8%) and 96 lesions (76.3%) were true Medina bifurcations. The 2-stent technique was used in 73 cases (57.9%). Everolimus-, zotarolimus-, and biolimus A9-eluting stents were implanted in 68 patients (44.2%), 46 patients (29.9%), and 40 patients (25.9%), respectively. At a median clinical follow-up of 551.5 days (interquartile range, 360.8-1045.5 days), MACEs occurred in 29 patients (18.8%). Ten patients (6.5%) died, and 2 deaths (1.3%) were adjudicated as cardiac. No patient had myocardial infarction or definite stent thrombosis (ST). One probable and 1 possible ST were adjudicated. TVR was required in 19 patients (12.3%) and target lesion revascularization was required in only 7 patients (4.5%).. In our experience, despite the presence of complex distal left main lesions, new DESs in ULMCA disease appear to be promising in terms of safety and efficacy at 2-year clinical follow-up.

    Topics: Aged; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Follow-Up Studies; Humans; Incidence; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Registries; Retrospective Studies; Sirolimus; Thrombosis; Treatment Outcome

2013
Clinical performance of a drug-eluting stent with a biodegradable polymer in an unselected patient population: the NOBORI 2 study.
    EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 2012, May-15, Volume: 8, Issue:1

    Previous studies for approved indications (on-label) have shown the good safety and efficacy profiles of the Nobori DES. We conducted a prospective, multicentre study to validate the clinical performance of this stent in a real-world setting.. A total of 3,067 consecutive patients undergoing a percutaneous coronary intervention with the Nobori DES were enrolled in the NOBORI 2 registry. At one and two years, 97% and 95% of patients, respectively, were available for follow-up. The rates of target lesion failure (TLF), cardiac death, myocardial infarction and target lesion revascularisations were: 3.9%, 1.2%, 1.9% and 2.2% at one year and 5.1%, 1.6%, 2.4% and 3.0% at two years. Overall, 2,242 patients (73%) were treated for at least one off-label indication. When comparing off-label and on-label groups, the results were: TLF 4.5% vs. 2.2%, p=0.003 at one year and 5.9% vs. 2.8%, p=0.001 at two years. The rate of stent thrombosis was 0.68%, and 0.80% at one and two years, respectively with no difference between the off-label and on-label groups (0.76% vs. 0.48%, p=0.6 and 0.89% vs. 0.61%, p=0.5).. The promising results previously observed in lower risk patients can be replicated in daily practice. As expected, in off-label indications, rates of adverse events were higher. Nevertheless, our results suggest the good and sustained performance of this stent system in high-risk patients with significant comorbidities and/or complex lesions.

    Topics: Absorbable Implants; Aged; Analysis of Variance; Angioplasty, Balloon, Coronary; Asia; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Europe; Female; Guideline Adherence; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Polymers; Practice Guidelines as Topic; Product Labeling; Prospective Studies; Prosthesis Design; Registries; Sirolimus; Thrombosis; Time Factors; Treatment Outcome

2012
Long-term outcome after the V stenting technique in de novo bifurcation lesions using drug-eluting stents.
    EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 2009, Volume: 5, Issue:2

    To report long-term outcome data on the V technique using drug-eluting stents.. From April 2002 to December 2006, 31 consecutive patients were successfully treated with V stenting of a de novo bifurcation lesion. The technique involves the deployment of two stents in the two branches of a bifurcation, the proximal edges of the stents just touching one another. Patients exclusively received either sirolimus- (10), paclitaxel- (20) or biolimus-eluting (one) stents. On average, 1.5 +/- 0.8 stents with a total length of 26.6 +/- 17.2 mm and 1.1 +/- 0.4 stents with a total length of 18.3 +/- 7.6 mm were deployed in the distal main vessel and side branch respectively. Mean duration of follow-up was 853 +/- 553 days. Within 30 days, three patients died; two other patients had definite stent thrombosis involving the V stents, both requiring re-PCI. Beyond 30 days and within one year, there was one death and three cases of target vessel revascularisation, including one target lesion revascularisation. There were a further three deaths (one cardiac) beyond one year. Eleven patients (35.5%) had angiographic follow-up, exhibiting a binary restenosis rate of 9.1% at 203 +/- 33 days.. In this real-world cohort, late clinical events stand in accord with studies on competitive techniques, but early outcome was less encouraging, probably due to the baseline risks.

    Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Netherlands; Paclitaxel; Prosthesis Design; Registries; Retrospective Studies; Risk Assessment; Risk Factors; Sirolimus; Thrombosis; Time Factors; Treatment Outcome

2009
Drug-eluting stents: is new necessarily better?
    Lancet (London, England), 2008, Sep-27, Volume: 372, Issue:9644

    Topics: Absorbable Implants; Biocompatible Materials; Coronary Stenosis; Drug-Eluting Stents; Humans; Metals; Polymers; Sirolimus; Thrombosis

2008