umirolimus has been researched along with Neointima* in 14 studies
7 trial(s) available for umirolimus and Neointima
Article | Year |
---|---|
Comparison Between Optical Frequency Domain Imaging and Intravascular Ultrasound for Percutaneous Coronary Intervention Guidance in Biolimus A9-Eluting Stent Implantation: A Randomized MISTIC-1 Non-Inferiority Trial.
Given the characteristic differences between intravascular ultrasound (IVUS) and optical frequency domain imaging (OFDI), their approach to therapeutic guidance during percutaneous coronary interventions (PCIs) and arterial healing response after stenting may also vary.. MISTIC-1 (The Multimodality Imaging Study in Cardiology cohort 1) is a multicenter, randomized-controlled, noninferiority trial that compared imaging end points between OFDI- and IVUS-guided PCI. Patients with stable coronary artery disease were randomly assigned to either OFDI- or IVUS-guided PCI using a Biolimus A9-eluting stent according to a prespecified protocol for imaging guidance. Stent sizing was based on external elastic lamina in IVUS-guided PCI while lumen up-size in OFDI-guided PCI. Postprocedural OFDI was investigated regardless of randomization, while operators in IVUS-guided PCI arm were blinded to the images. The primary end point was in-segment minimum lumen area assessed using OFDI at 8 months, while the secondary end point was a composite of cardiovascular mortality, target-vessel myocardial infarction, or target-lesion revascularization (device-oriented composite end point). Patients were followed up to 3 years after the index procedure.. OFDI-guided PCI was not inferior to IVUS-guided PCI in terms of in-segment minimum lumen area at 8 months. Although a small sample size was acknowledged, OFDI could be an alternative to IVUS when considering intracoronary imaging-guided PCI in selected populations with coronary artery diseases. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03292081. Topics: Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Japan; Male; Neointima; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2020 |
Randomized comparison of sirolimus eluting, and biolimus eluting bioresorbable polymer stents: the SORT-OUT VII optical coherence tomography study.
To show non-inferiority of the 67- or 87 µm thick, sirolimus-eluting Orsiro drug eluting stent (DES) to the 122 µm thick, biolimus-eluting Nobori DES regarding size of vessel lumen outside the stent at 13-month follow-up.. This study was a substudy to the SORT-OUT VII trial, a prospective, 1:1-randomized, comparison of the two stents in patients with stable coronary artery disease or acute coronary syndrome. Optical coherence tomography was acquired after percutaneous coronary intervention and at 13-month follow-up. The substudy was powered to access non-inferiority (Δ = 0.60 mm2) of the Orsiro DES to the Nobori DES for the primary endpoint of mean extra stent lumen (ESL) i.e. vessel lumen outside the stent at 13-month follow-up. We randomized 124 patients to Orsiro (n = 60) or Nobori (n = 64). Due to a difference in the one-sided 95%-confidence interval of 0.26 mm2, but increased to 0.82 mm2 after appropriate log-transformation, it could not be rejected that Orsiro exceeded the non-inferiority limit. Testing for superiority, Orsiro had a significantly larger mean ESL at follow-up (Orsiro: 0.11 mm2 [0.02;0.30] mm2, Nobori: 0.03 mm2 [0.00;0.17] mm2, P = 0.04). Stent strut coverage was, Orsiro: 97.6 % [93.8;99.4]%, and Nobori: 96.3 % [90.5;98,6]% (P = 0.13).. Orsiro DES had a significantly larger mean ESL at follow-up and it could not be excluded that Orsiro exceeded the limit for non-inferiority. Nobori DES had a more heterogeneous distribution of neointima but stent strut coverage did not differ significantly between the two stents. Topics: Absorbable Implants; Angioplasty, Balloon, Coronary; Coronary Stenosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Neointima; Normal Distribution; Polymers; Prospective Studies; Prosthesis Design; Reference Values; Risk Assessment; Severity of Illness Index; Sirolimus; Statistics, Nonparametric; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Vascular Patency | 2018 |
The OCT-ORION Study: A Randomized Optical Coherence Tomography Study Comparing Resolute Integrity to Biomatrix Drug-Eluting Stent on the Degree of Early Stent Healing and Late Lumen Loss.
Durable polymers used in drug-eluting stents are considered a potential cause of hypersensitivity inflammatory response adversely affecting stent healing. Using a sequential follow-up with optical coherence tomography, we compared the differences in healing profiles of 2 drug-eluting stents with a biodegradable or durable polymer.. Sixty patients with multivessel disease were prospectively enrolled to receive both study stents, which were randomly assigned to 2 individual vessels, a Resolute Integrity zotarolimus-eluting stent with a durable BioLinx polymer and a BioMatrix NeoFlex Biolimus A9-eluting stent with a biodegradable polylactic acid polymer. Optical coherence tomography was performed at baseline, then in 5 randomly assigned monthly groups at 2 to 6 months, and at 9 months in all patients. The primary end point was the difference in optical coherence tomography strut coverage at 9 months. Key secondary end points included angiographic late lumen loss and composite major adverse cardiac events (cardiac death, myocardial infarction, target lesion revascularization, and definite or probable stent thrombosis) at 9 months. Resolute Integrity zotarolimus-eluting stent showed significantly better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent at 2 to 6 months (. Despite having a durable polymer, Resolute Integrity zotarolimus-eluting stent exhibited better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent having a biodegradable polymer; both showed similar antiproliferative efficacy. This novel, longitudinal, sequential optical coherence tomography protocol using each patient as own control could achieve conclusive results in small sample size.. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01742507. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Hong Kong; Humans; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2018 |
Two-year vascular responses to drug-eluting stents with biodegradable polymer versus durable polymer: An optical coherence tomography sub-study of the NEXT.
This study aimed to compare very late vascular response after stent implantation between everolimus-eluting stent (EES) with a thin, non-adhesive, durable, biocompatible fluorinated polymer and biolimus-eluting stent (BES) with a biodegradable polymer by optical coherence tomography (OCT).. In the NOBORI-BES Versus XIENCE V/PROMUS-EES Trial (NEXT), a formal OCT substudy investigated 48 patients (27 EES-treated lesions in 23 patients and 28 BES-treated lesions in 25 patients) with 2-year (18-30 months) follow-up imaging at 18 centers. The percentage of uncovered strut by neointima was significantly lower in EES compared with BES (2.1±4.7% vs. 7.9±10.8%, p=0.013). The percentage of malapposed strut was not different between EES and BES (0.1±0.3% vs. 0.5±1.3%, p=0.138). The frequency of stent with evagination, which is identified as outward bulges in the luminal contour between struts, was significantly lower in EES compared with BES (22% vs. 86%, p<0.001). The frequency of neoatherosclerosis was not different between EES and BES (11% vs. 11%, p=1.000).. At 2 years after stent implantation, uncovered stent strut by neointima and evagination were less frequently observed in EES compared with BES. This OCT study suggests that the very late vascular response is different between EES and BES. Topics: Aged; Biocompatible Materials; Coronary Vessels; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Polymers; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2017 |
Intravascular imaging comparison of two metallic limus-eluting stents abluminally coated with biodegradable polymers: IVUS and OCT results of the DESTINY trial.
We sought to compare, by means of IVUS and OCT imaging, the performance of a novel sirolimus-eluting drug-eluting stent (DES) with biodegradable polymer (Inspiron™) to the Biomatrix™ DES. From the DESTINY trial, a total of 70 randomized patients (2:1) were enrolled in the IVUS substudy (Inspiron™, n = 46; Biomatrix™: n = 20) while 25 patients were evaluated with OCT (Inspiron™, n = 19; Biomatrix™: n = 06) at 9-month follow-up. The main endpoints were % of neointimal tissue obstruction (IVUS) and neointimal stut coverage (OCT) at 9 months. Patients treated with both DES had very little NIH formation at 9 months either by IVUS (% of NIH obstruction of 4.9 ± 4.1 % with Inspiron™ vs. 2.7 ± 2.9 % with Biomatrix™, p = 0.03) or by OCT (neointimal thickness of 144.2 ± 72.5 µm Inspiron™ vs. 115.0 ± 53.9 µm with Biomatrix™, p = 0.45). Regarding OCT strut-level assessment, again both devices showed excellent 9-month performance, with high rates of strut coverage (99.49 ± 1.01 % with Inspiron™ vs. 97.62 ± 2.21 % with Biomatrix™, p < 0.001) and very rare malapposition (0.29 ± 1.06 % with Inspiron™ vs. 0.53 ± 0.82 % with Biomatrix™, p = 0.44). Patients with any uncovered struts were more frequently identified in the Biomatrix™ group (9.78 ± 7.13 vs. 2.29 ± 3.91 %, p < 0.001). In the present study, midterm IVUS and OCT evaluations showed that both new generation DES with biodegradable polymer were effective in terms of suppressing excessive neointimal response, with very high rates of apposed and covered struts, suggesting a consistent and benign healing pattern. Topics: Absorbable Implants; Cardiovascular Agents; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Humans; Metals; Neointima; Percutaneous Coronary Intervention; Polymers; Predictive Value of Tests; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2017 |
Polymer-Free Biolimus A9-Coated Stents in the Treatment of De Novo Coronary Lesions: 4- and 12-Month Angiographic Follow-Up and Final 5-Year Clinical Outcomes of the Prospective, Multicenter BioFreedom FIM Clinical Trial.
The purpose of this study was to evaluate the efficacy and long-term outcomes of a novel polymer/carrier-free drug-coated stent (DCS) in patients with de novo coronary lesions.. The BioFreedom (BFD) DCS incorporates a low-profile, stainless-steel platform, with a surface that has been modified to create a selectively microstructured abluminal surface that allows adhesion and further release of Biolimus A9 (Biosensors Europe SA, Morges, Switzerland).. A total of 182 patients (183 lesions) were randomized into a 1:1:1 ratio for treatment with BFD "standard dose" (BFD) or BFD "low dose" (BFD-LD) versus first-generation paclitaxel-eluting stents (PES) at 4 sites in Germany.. Baseline and procedural characteristics were well matched. At 4-month angiographic follow-up (Cohort 1, n = 75), in-stent late lumen loss (LLL) was significantly lower with BFD and BFD-LD versus PES (0.08 and 0.12 mm vs. 0.37 mm, respectively; p < 0.0001 for BFD vs. PES, and p = 0.002 for BFD-LD vs. PES). At 12 months (Cohort 2, n = 107), in-stent LLL (primary endpoint) was 0.17 mm in BFD versus 0.35 mm in PES (p = 0.001 for noninferiority; p = 0.11 for superiority); however, the BFD-LD (0.22 mm) did not reach noninferiority (p = 0.21). At 5 years (175 of 182), there were no significant differences in major adverse cardiac events (23.8%, 26.4%, and 20.3%) and clinically indicated target lesion revascularization (10.8%, 13.4%, and 10.2%) for BFD, BFD-LD, and PES, respectively; also, there was no definite/probable stent thrombosis reported.. The BFD, but not the BFD-LD, demonstrated noninferiority versus PES in terms of in-stent LLL, a surrogate of neointimal hyperplasia, at 12-month follow-up. At 5 years, clinical event rates were similar, without occurrence of stent thrombosis in all groups. (BioFreedom FIM Clinical Trial; NCT01172119). Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Germany; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Neointima; Paclitaxel; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Risk Factors; Single-Blind Method; Sirolimus; Stainless Steel; Surface Properties; Time Factors; Treatment Outcome | 2016 |
Favorable vessel healing after nobori biolimus A9-eluting stent implantation-6- and 12-month follow-up by optical coherence tomography.
Nobori is a novel biolimus A9-eluting stent (BES) coated with a biodegradable polymer only on the abluminal side, which degrades over 6-9 months post-stent deployment. The course of vessel reaction after deployment at these time points remains unclear.. We serially evaluated 28 BES implanted in de novo coronary lesions of 23 patients using optical coherence tomography (OCT) at 6 and 12 months post-stenting. Standard OCT variables, the percentage of stent with peri-strut low-intensity area (PLIA, a region around stent struts homogenously showing lesser intensity than the surrounding tissue, suggesting fibrin deposition or impaired neointima maturation) and that with in-stent thrombi were evaluated. There was a significant, but small increase in neointimal thickness (72 ± 23 to 82 ± 25 µm, P=0.006) from the 6- to the 12-month follow-up, without a significant decrease in minimum lumen area (P=0.30). The incidences of uncovered and malapposed struts were low at 6 months and reduced further at 12 months (3.96 ± 3.97% to 1.51 ± 1.63%, P=0.001, and 0.50 ± 1.84% to 0.06 ± 0.24%, P=0.20, respectively). The frequency of stent with PLIA decreased during the follow-up (57% to 32%, P=0.05) and that with in-stent thrombi also numerically decreased (7% to 0%, P=0.24).. Neointimal hyperplasia was persistently suppressed following BES implantation up to 12 months. Simultaneously, favorable vessel healing was achieved at 6 months without a delaying adverse reaction for up to 12 months. Topics: Aged; Biodegradable Plastics; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Hyperplasia; Male; Middle Aged; Neointima; Regeneration; Sirolimus; Tomography, Optical Coherence | 2014 |
7 other study(ies) available for umirolimus and Neointima
Article | Year |
---|---|
Accuracy of optical frequency domain imaging for evaluation of coronary adventitial vasa vasorum formation after stent implantation in pigs and humans - a validation study - .
Coronary adventitia harbors a wide variety of components, such as inflammatory cells and vasa vasorum (VV). Adventitial VV initiates the development of coronary artery diseases as an outside-in supply route of inflammation. We have recently demonstrated that drug-eluting stent implantation causes the enhancement of VV formation, with extending to the stent edges in the porcine coronary arteries, and also that optical frequency domain imaging (OFDI) is capable of visualizing VV in humans in vivo. However, it remains to be fully validated whether OFDI enables the precise measurement of VV formation in pigs and humans.. In the pig protocol, a total of 6 bare-metal stents and 12 drug-eluting stents were implanted into the coronary arteries, and at 1 month, the stented coronary arteries were imaged by OFDI ex vivo. OFDI data including the measurement of VV area at the stent edge portions were compared with histological data. There was a significant positive correlation between VV area on OFDI and that on histology (R=0.91, P<0.01). In the human protocol, OFDI enabled the measurement of the VV area at the stent edges after coronary stent implantation in vivo.. These results provide the first direct evidence that OFDI enables the precise measurement of the VV area in coronary arteries after stent implantation in pigs and humans. Topics: Adventitia; Aged; Aged, 80 and over; Animals; Aspirin; Clopidogrel; Coronary Stenosis; Coronary Vessels; Disease Progression; Drug-Eluting Stents; Everolimus; Female; Humans; Interferometry; Male; Middle Aged; Neointima; Neovascularization, Physiologic; Platelet Aggregation Inhibitors; Postoperative Period; Prosthesis Implantation; Sirolimus; Stents; Swine; Swine, Miniature; Ticlopidine; Tomography, Optical Coherence; Vasa Vasorum; Vasculitis | 2015 |
Serial Optical Coherence Tomography Evaluation at 6, 12, and 24 Months After Biolimus A9-Eluting Biodegradable Polymer-Coated Stent Implantation.
The Nobori (Terumo Corporation, Tokyo, Japan) is a biolimus A9-eluting stent (BES) featured with a biodegradable polymer coated on the abluminal side only. We previously reported that favourable vessel healing was achieved at 6-12 months after BES implantation. However, detailed long-term vessel reaction after BES deployment is unclear.. Twenty-two BESs were serially evaluated using optical coherence tomography (OCT) at 6, 12, and 24 months after stenting. Average neointimal thickness, uncovered struts, and neointimal unevenness score (each cross-section as maximum neointimal thickness in 1 cross section divided by the average neointimal thickness of the same cross-section) were manually measured. In addition, we evaluated the percentage of struts with peri-strut low-intensity area (a region around stent struts that homogenously showed less intensity than the surrounding tissue, which suggests fibrin deposition or impaired neointima maturation), thrombi, and atherogenic neointimas (neointimas containing a diffuse border and poor-signal region with invisible struts due to marked signal attenuation).. Serial OCT observation revealed a small gradual increase in neointimal thickness from 6 to 24 months (73 ± 24 μm; 81 ± 26 μm; and 108 ± 35 μm, respectively, P = 0.001) with a nonsignificant decrease in the lumen area (6.36 ± 1.98 mm(2); 6.18 ± 2.04 mm(2); and 5.87 ± 2.06 mm(2); P = 0.72). Frequency of uncovered struts (3.89 ± 3.91%; 1.55 ± 1.63%; and 0.23 ± 0.67%; P = 0.001), neointimal unevenness score (1.95 ± 0.18% to 1.86 ± 0.19% to 1.78 ± 0.17; P = 0.012), percentage of thrombi (5%, 0%, and 0%; P = 0.37) and peri-strut low-intensity area (6.8%, 5.1%, and 1.6%; P = 0.017) decreased from 6 to 12 and 24 months. Atherogenic neointima was not observed in the event-free OCT cohort.. The Nobori stent achieved acceptable long-term vessel healing, mostly without adverse vessel reactions. Topics: Aged; Coated Materials, Biocompatible; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Neointima; Polymers; Prospective Studies; Prosthesis Design; Reproducibility of Results; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2015 |
Automated assessment and 3-dimensional visualization of the pattern of neointimal tissue maturity in vivo following drug-eluting stent implantation.
Topics: Algorithms; Angina, Unstable; Automation; Cardiovascular Agents; Coronary Vessels; Drug-Eluting Stents; Humans; Image Interpretation, Computer-Assisted; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Predictive Value of Tests; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Wound Healing | 2014 |
Long-term coronary arterial response to biodegradable polymer biolimus-eluting stents in comparison with durable polymer sirolimus-eluting stents and bare-metal stents: five-year follow-up optical coherence tomography study.
The long-term coronary arterial response of biodegradable polymer biolimus-eluting stents (BES) remains unclear. We sought to evaluate the coronary arterial response of biodegradable polymer BES at 5 years after stent implantation using optical coherence tomography (OCT) as compared with that of durable polymer sirolimus-eluting stents (SES) and bare-metal stents (BMS).. Five-year follow-up OCT was performed in 30 patients with 33 stents (10 with 12 BES; 10 with 11 SES; 10 with 10 BMS). Quantitative parameters and qualitative characteristics of the neointima were evaluated. A total of 5178 struts (BES, n = 2056; SES, n = 1410; BMS, n = 1712) were analyzed.. Uncovered struts were found in 15 out of 2055 struts in the BES (weighted estimate 0.01%, 95% confidence intervals [CI]: 0.00-0.33%) and 54 out of 1410 struts in the SES (0.11%, 95% CI: 0.00-3.33%) (odds ratio [OR] 0.12, 95% CI: 0.01-1.95, p = 0.13). None of 1712 struts were uncovered in the BMS. Cross-sectional qualitative analysis of neointimal tissue showed that the frequency of lipid-laden neointima tended to be lower in the BES (2.26%, 95% CI: 0.38-12.3%) compared with the SES (9.90%, 95% CI: 4.37-20.9%; OR 0.21, 95% CI 0.03-1.16, p = 0.07), and was similar to the BMS (2.23%, 95% CI: 0.54-8.74%; OR 0.98, 95% CI 0.13-7.14, p = 0.98).. Biodegradable polymer BES shows a favorable coronary arterial response compared with SES, but different response with BMS at 5 years follow-up. The observed frequency of in-stent neoatherosclerosis within BES was similar to BMS and tended to be lower than SES. Topics: Absorbable Implants; Aged; Aged, 80 and over; Atherosclerosis; Coronary Angiography; Coronary Vessels; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Lipids; Male; Metals; Neointima; Polymers; Sirolimus; Stents; Ticlopidine; Time Factors; Tomography, Optical Coherence | 2014 |
Comparison of vascular response between durable and biodegradable polymer-based drug-eluting stents in a porcine coronary artery model.
Biodegradable polymer-based drug-eluting stents are thought to be safer than durable polymer-based stents. However, the long-term vascular response remains unclear. The aim of this study was to compare the biocompatibility of durable polymer-based sirolimus-eluting (SES) and everolimus-eluting (EES) stents with biodegradable polymer-based biolimus-eluting (BES) stents in a porcine coronary model. Stents were implanted in porcine coronaries. Acetylcholine challenge tests and optical coherence tomography (OCT) examination were performed at one month. Animals were sacrificed at three and six months (n=6 each), and the stents were analysed histologically. At one month, acetylcholine challenge tests revealed a trend towards greatest vasoconstriction in SES, less in BES, and least in EES, but the differences were not significant. OCT analysis demonstrated the highest incidence of uncovered struts in SES, followed by BES, while EES showed almost complete strut coverage (41.7±27.0%, 24.5±23.8%, 0.4±0.8%, respectively; p=0.004). Upon histological analysis at three months, SES showed a significantly higher inflammatory score than BES and EES (2.9±1.4, 0.8±0.9, 0.5±0.4, respectively; p=0.001), and this was maintained at six months (1.6±1.5, 0.3±0.3, 0.4±0.6, respectively; p=0.049). While SES showed an increased inflammatory reaction, EES and BES showed minimal inflammation. These results indicate that the late inflammatory reaction does not necessarily depend on degradability of the polymer, if the combination of the drug, metal, and polymer is biocompatible. Topics: Absorbable Implants; Acetylcholine; Animals; Coated Materials, Biocompatible; Coronary Angiography; Coronary Vessels; Drug-Eluting Stents; Everolimus; Inflammation; Materials Testing; Models, Animal; Neointima; Polymers; Sirolimus; Swine; Tomography, Optical Coherence; Vasodilator Agents | 2014 |
Very long-term follow-up of strut apposition and tissue coverage with Biolimus A9 stents analyzed by optical coherence tomography.
First generation drug-eluting stents (DES) are associated with reduced in-stent restenosis but significant increased risk of very late stent thrombosis (VLST). The absence of polymer in DES systems may reduce the occurrence of VLST. Optic coherence tomography (OCT) has been used for stent analysis as a surrogate safety endpoint. This study aimed to assess the long-term follow up of strut apposition and tissue coverage of BioMatrix DES by OCT. 20 patients undergoing BioMatrix DES (n = 15) or S-Stent BMS (n = 5) implantation were followed for at least 5 years and evaluated by quantitative coronary angiography, intravascular ultrasound, and OCT. The difference between the stent types was evaluated by nonparametric Mann-Whitney U test while categorical variables were evaluated by Fisher exact test. Rates of in-stent late loss were similar between groups [0.40 (0.21;0.77) vs. 0.68 (0.66; 0.82) mm, p = 0.205, for BioMatrix and S-Stent, respectively]. The vessel, stent and lumen volumes did not differ between groups. Patients treated with BioMatrix had significantly less stent obstruction [5.6 (4.4;9.7) vs. 28.6 (24.7;29.0) %, p = 0.001]. OCT analysis of 12 stents (Biomatrix = 9 and S-Stent = 3) demonstrated 126 (8.7 %) uncovered struts in the BioMatrix group compared to 23 (4.0 %) in the S-Stent group (p = 0.297), being the majority of them well apposed (117/126 and 21/23, respectively, p = 0.292). Only 9 (0.6 %) struts in the DES and 2 (0.4 %) struts in the BMS groups were simultaneously uncovered and malapposed (p = 0.924). BioMatrix DES was associated with lower rates of in-stent obstruction, and similar percentage of neointimal coverage on struts and of complete strut apposition. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Predictive Value of Tests; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2013 |
In vivo comparison of a polymer-free Biolimus A9-eluting stent with a biodegradable polymer-based Biolimus A9 eluting stent and a bare metal stent in balloon denuded and radiated hypercholesterolemic rabbit iliac arteries.
To evaluate the effect of a polymer-free Biolimus A9-eluting stent [BioFreedom (BF)], compared with that of a biodegradable polymer-based Biolimus A9-eluting stent [BioMatrix Flex (BMF)] and a bare metal stent (BMS) in balloon denuded and radiated hypercholesterolemic rabbit iliac arteries.. Rabbits were fed with 1% cholesterol diet (n = 14) for 14 days, both iliac arteries were balloon denuded and radiated, and then rabbits were switched to 0.15% cholesterol diet. After 4 weeks, BF (n = 8), BMF (n = 8), and BMS (n = 8) were deployed in denuded and radiated areas. Four weeks later animals were euthanized, arterial segments were processed for morphometry.. The neointimal area in vessels implanted with BF stents was significantly less than that seen in vessels implanted with BMS (0.90 mm(2) ± 0.14 vs. 1.29 mm(2) ± 0.23, P <0.01). Percent fibrin and fibrin score were higher with BMF stents compared to BMS (P <0.03 and <0.04) and giant cell number was significantly higher with both BMF and BF stents (P < 0.01 for both). Percent endothelialization was significantly higher and % uncovered struts were lower with BMS compared to either BMF or BF stents (P < 0.05 for both).. This study demonstrates that compared to BMS, BF stents significantly decreased neointimal hyperplasia. Topics: Absorbable Implants; Angioplasty, Balloon; Animals; Atherosclerosis; Cardiovascular Agents; Constriction, Pathologic; Disease Models, Animal; Drug-Eluting Stents; Fibrin; Hypercholesterolemia; Hyperplasia; Iliac Artery; Inflammation; Male; Metals; Neointima; Plaque, Atherosclerotic; Polymers; Prosthesis Design; Rabbits; Sirolimus; Stents; Time Factors | 2012 |