umirolimus has been researched along with Myocardial-Infarction* in 59 studies
3 review(s) available for umirolimus and Myocardial-Infarction
Article | Year |
---|---|
A mixed treatment comparison for short- and long-term outcomes of bare-metal and drug-eluting coronary stents.
The increasing use of drug eluting stents in interventional cardiology calls for assessment of their efficacy and safety, both among drug-eluting and bare-metal stents, in the context of rational decision making.. We searched for papers that compared any of the sirolimus-eluting stent, paclitaxel-eluting stent, drug- eluting stent, biodegradable stent, everolimus-eluting stent, zotarolimus-resolute eluting stent, biolimus- eluting stent, bare-metal stent and zotarolimus-eluting stent. The search was contacted through Medline, the Cochrane database, Embase, TCTMD, ClinicalTrials.gov, Clinical Trial Results, CardioSource, abstracts and presentations from major cardiovascular meetings. We also searched for further articles cited by selected papers. Furthermore, important conferences and relevant proceedings and abstracts, such as the American Heart Association, American College of Cardiology, Transcatheter Cardiovascular Therapeutics, Society of Cardiovascular Angiography and Intervention, European Society of Cardiology, and Euro-PCR, were also searched. Inclusion criteria were: randomised controlled trials (RCTs), size of study (≥100 patients), duration more than 6 months and definition of reported endpoints (target vessel revascularization, thrombosis, myocardial infarction and cardiac death). Analysis of the data was performed for short-term (less than a year) and long-term outcomes (more than a year). A mixed treatment comparison approach was utilised for the data analysis.. Based on the rankings of each treatment, a distinct difference between the 2nd and 1st generation stents was identified. We can conclude that everolimus, zotarolimus-resolute and biolimus eluting stents carry the highest probabilities of being superior for all endpoints. Topics: Aged; Aged, 80 and over; Antineoplastic Agents, Phytogenic; Death; Drug-Eluting Stents; Everolimus; Humans; Immunosuppressive Agents; Male; Metals; Middle Aged; Myocardial Infarction; Paclitaxel; Percutaneous Coronary Intervention; Randomized Controlled Trials as Topic; Sirolimus; Stents; Thrombosis; Treatment Outcome | 2016 |
Impact of side branch stenting on five-year long-term clinical outcome with the bifurcation-dedicated Axxess Biolimus A9-eluting stent system.
Our aim was to evaluate the five-year clinical impact of side branch (SB) stenting with a drug-eluting stent (DES) following Axxess stent implantation in coronary bifurcation lesions.. Four hundred patients treated with Axxess were pooled from the AXXESS Plus and DIVERGE five-year follow-up studies. We compared unadjusted and propensity-adjusted major adverse clinical events (MACE) between Axxess with no SB stenting ("Axxess provisional") versus Axxess with SB stenting ("Axxess additional"). "Axxess additional" had no impact on the MACE rate, with unadjusted and adjusted HR 1.59 (95% CI: 0.95-2.64) and 1.37 (95% CI: 0.88-2.13), respectively. No differences were seen in the individual components of death, myocardial infarction and ischaemia-driven target lesion revascularisation, respectively, both in unadjusted (HR 0.92 [95% CI: 0.38-2.19]; HR 1.73 [95% CI: 0.78-3.82]; HR 1.65 [95% CI: 0.84-3.26]) and adjusted analysis (HR 0.92 [95% CI: 0.41-2.09]; HR 1.13 [95% CI: 0.59-2.17]; HR 1.31 [95% CI: 0.74-2.31]). No differences in definite stent thrombosis were seen with unadjusted HR 2.1 (95% CI: 0.45-9.88) and adjusted HR 1.0 (95% CI: 0.32-3.1).. Stenting the SB following Axxess implantation does not impact on long-term clinical outcomes compared to MV stenting only. The Axxess stent system offers a safe and tailored alternative for the treatment of coronary bifurcation lesions. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Kaplan-Meier Estimate; Logistic Models; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Propensity Score; Proportional Hazards Models; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2015 |
Comparison of newer-generation drug-eluting with bare-metal stents in patients with acute ST-segment elevation myocardial infarction: a pooled analysis of the EXAMINATION (clinical Evaluation of the Xience-V stent in Acute Myocardial INfArcTION) and COMFO
This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI).. Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES.. Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year.. Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p < 0.0001) and a lower risk of target-vessel infarction (RR: 0.36; 95% CI: 0.14 to 0.92; p = 0.03). Newer-generation DES also reduced the risk of definite stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS.. Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up. Topics: Aged; Cardiovascular Agents; Chi-Square Distribution; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Metals; Middle Aged; Myocardial Infarction; Odds Ratio; Percutaneous Coronary Intervention; Prosthesis Design; Randomized Controlled Trials as Topic; Recurrence; Risk Assessment; Risk Factors; Sirolimus; Stents; Time Factors; Treatment Outcome | 2014 |
32 trial(s) available for umirolimus and Myocardial-Infarction
Article | Year |
---|---|
Randomized comparison between 2-link cell design biolimus A9-eluting stent and 3-link cell design everolimus-eluting stent in patients with de novo true coronary bifurcation lesions: the BEGIN trial.
The appropriate stent platform for treating coronary bifurcation lesions (CBLs) remains controversial. Previous bench tests have demonstrated the superiority of a 2-link cell design to 3-link cell design for creating inter-strut dilation at the side branch ostium. This randomized multicenter prospective BEGIN trial compared the biodegradable polymer-based biolimus A9-eluting stent (2-link BES) with the durable polymer-based cobalt chromium everolimus-eluting stent (3-link EES) in 226 patients with de novo CBLs. Patients with true bifurcations, defined as > 50% stenosis in the main vessel and side branch (SB) and an SB diameter > 2.25 mm, were enrolled. Guide wire re-crossing to the distal cell (near the carina) in the jailed SB and final kissing inflation were recommended. The SB angiographic endpoint was < 50% stenosis diameter. Left-main CBLs (13.5% vs. 13.0%) and 2-stent technique (30.6% vs. 22.6%) rates were similar. The primary endpoints (minimum lumen diameter at the SB ostium measured at an independent core laboratory at the 8-month follow-up) were comparable (1.64 ± 0.50 mm vs. 1.63 ± 0.51 mm, p = 0.976). There was no significant difference in composite outcomes of cardiac death, myocardial infarction, or target vascular revascularization at 12 months (7.4% vs. 8.0%, p = 0.894). Two-link BES and 3-link EES showed similar 8-month angiographic and 1-year clinical outcomes for true CBLs. Topics: Absorbable Implants; Aged; Aged, 80 and over; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Humans; Japan; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome | 2019 |
Comparison of the polymer-free biolimus-coated BioFreedom stent with the thin-strut biodegradable polymer sirolimus-eluting Orsiro stent in an all-comers population treated with percutaneous coronary intervention: Rationale and design of the randomized SO
In patients with increased bleeding risk during dual antiplatelet therapy, the biolimus A9-coated BioFreedom, a stainless steel drug-coated stent devoid of polymer, has shown superiority compared to a bare-metal stent. The aim of this study was to investigate whether the polymer-free biolimus A9-coated BioFreedom is noninferior to a modern thin-strut biodegradable polymer cobalt-chromium sirolimus-eluting Orsiro stent in an all-comers patient population treated with percutaneous coronary intervention.. The multicenter SORT OUT IX trial (NCT02623140) randomly assigned all-comers patients to treatment with the BioFreedom drug-coated stent or the biodegradable polymer Orsiro stent in 4 Danish University Hospitals. The primary end point target lesion failure is a composite of cardiac death, myocardial infarction (not related to other than index lesion), or target lesion revascularization within 12 months. Clinically driven event detection based on Danish registries will be used and continue through 5 years. Assuming an event rate of 4.2% in each stent group, 1,563 patients in each treatment arm will provide 90% power to detect noninferiority of the drug-coated BioFreedom stent with a noninferiority margin of 2.1%.. A total of 3,150 patients have been randomized and enrolled in the study.. The SORT OUT IX trial will determine whether the drug-coated BioFreedom stent is noninferior to a modern biodegradable polymer Orsiro stent. Topics: Absorbable Implants; Cause of Death; Chromium Alloys; Coronary Stenosis; Denmark; Drug-Eluting Stents; Equipment Design; Humans; Immunosuppressive Agents; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Sirolimus; Time Factors | 2019 |
Early Strut Coverage in Patients Receiving Drug-Eluting Stents and its Implications for Dual Antiplatelet Therapy: A Randomized Trial.
This study sought to measure early strut coverage in patients receiving drug-eluting stents (DESs) and to explore the feasibility of short-term dual antiplatelet therapy (DAPT) based on the degree of early strut coverage.. Data for early strut coverage in patients receiving new-generation DESs, and its implications for DAPT continuation were limited.. A randomized, multicenter trial was conducted in 894 patients treated with DESs. Patients were randomly assigned to everolimus-eluting stent (EES) (n = 444) or biolimus-eluting stent (BES) (n = 450) groups and optical coherence tomography (OCT)-guided (n = 445) or angiography-guided (n = 449) implantation groups using a 2-by-2 factorial design. Early strut coverage was measured as the percentage of uncovered struts on 3-month follow-up OCT examination. The primary outcome was the difference in early strut coverage between EES and BES groups and between OCT- and angiography-guided implantation groups. The secondary outcome was a composite of cardiac death, myocardial infarction, stent thrombosis, and major bleeding during the first 12 months post-procedure in patients receiving 3-month DAPT based on the presence of early strut coverage (≤6% uncovered) on 3-month follow-up OCT.. Three-month follow-up OCT data were acquired for 779 patients (87.1%). The median percentage of uncovered struts at 3 months was 8.9% and 8.2% in the EES and BES groups, respectively (p = 0.69) and was lower in the OCT-guided group (7.5%) than in the angiography-guided group (9.9%; p = 0.009). Favorable early strut coverage (≤6% uncovered strut) was observed in 320 of 779 patients (41.1%). At 12 months, the composite event rarely occurred in the 3-month (0.3%) or 12-month (0.2%) DAPT groups (p = 0.80).. OCT-guided DES implantation improved early strut coverage compared with angiography-guided DES implantation, with no difference in strut coverage between EES and BES groups. Short-term DAPT may be feasible in selected patients with favorable early strut coverage (Determination of the Duration of the Dual Antiplatelet Therapy by the Degree of the Coverage of The Struts on Optical Coherence Tomography From the Randomized Comparison Between Everolimus-eluting Stents Versus Biolimus A9-eluting Stents [DETECT-OCT]; NCT01752894). Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Thrombosis; Drug Therapy, Combination; Drug-Eluting Stents; Everolimus; Feasibility Studies; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Prosthesis Design; Republic of Korea; Risk Factors; Sirolimus; Stroke; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2018 |
Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease: Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable P
This analysis investigates the 5-year outcomes of the biodegradable polymer biolimus-eluting stent (BP-BES) and durable polymer everolimus-eluting stent (DP-EES) in an all-comers population undergoing percutaneous coronary intervention.. Recent 1- and 3-year results from randomized trials have indicated similar safety and efficacy outcomes of BP-BES and DP-EES. Whether benefits of the biodegradable polymer device arise over longer follow-up is unknown. Moreover, in-depth, prospective, long-term follow-up data on metallic drug-eluting stents with durable or biodegradable polymers are scarce.. The COMPARE II trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent) was a prospective, randomized, multicenter, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BP-BES or DP-EES. The pre-specified endpoint at 5 years was major adverse cardiac events, a composite of cardiac death, nonfatal myocardial infarction, or target vessel revascularization.. Five-year follow-up was available in 2,657 patients (98%). At 5 years, major adverse cardiac events occurred in 310 patients (17.3%) in the BP-BES group and 142 patients (15.6%) in the DP-EES group (p = 0.26). The rate of the combined safety endpoint all-cause death or myocardial infarction was 15.0% in the BP-BES group versus 14.8% in the DP-EES group (p = 0.90), whereas the efficacy measure target vessel revascularization was 10.6% versus 9.0% (p = 0.18), respectively. Interestingly, definite stent thrombosis rates did not differ between groups (1.5% for BP-BES vs. 0.9% for DP-EES; p = 0.17).. The 5-year analysis comparing biodegradable polymer-coated BES and the durable polymer-coated EES confirms the initial early- and mid-term results regarding similar safety and efficacy outcomes in this all-comers percutaneous coronary intervention population. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2017 |
Safety and Efficacy of Polymer-Free Biolimus A9-Coated Versus Bare-Metal Stents in Orally Anticoagulated Patients: 2-Year Results of the LEADERS FREE Oral Anticoagulation Substudy.
The aim of this study was to compare the performance of drug-coated stents (DCS) versus bare-metal stents (BMS) in patients who are candidates for long-term oral anticoagulation (OAC) after percutaneous coronary interventions.. The randomized controlled LEADERS FREE (A Randomized Clinical Evaluation of the BioFreedom™ Stent) trial demonstrated the superior safety and efficacy of a polymer-free biolimus A9 DCS compared with a similar BMS used with 1 month of dual antiplatelet therapy in 2,466 patients at high bleeding risk.. The 2 stents were compared in a pre-specified analysis of the 879 LEADERS FREE patients (35.6%) scheduled to remain on OAC after percutaneous coronary intervention. The primary safety endpoint was a composite of cardiac death, myocardial infarction, and stent thrombosis. The primary efficacy endpoint was the incidence of clinically driven target lesion revascularization.. Baseline characteristics of 448 DCS and 431 BMS recipients were similar, 78.8% had histories of atrial fibrillation, and 21% presented with acute coronary syndromes. Four hundred patients in the DCS group and 376 in the BMS group were discharged on OAC after percutaneous coronary intervention. At 2 years, for the DCS and BMS recipients, respectively, the incidence of clinically driven target lesion revascularization was 7.5% versus 11.2% (hazard ratio: 0.63; 95% confidence interval: 0.40 to 1.01; p = 0.0514), the safety endpoint was reached by 14.4% and 15.0% (p = NS), and the rates of major bleeding events (Bleeding Academic Research Consortium 3 to 5) were 10.7% and 12.9% (p = NS).. The efficacy advantage of DCS over BMS up to 2 years appears confirmed in patients on long-term OAC. Despite the very short course of dual antiplatelet therapy, both the DCS and BMS groups experienced similarly high rates of major bleeding. (A Randomized Clinical Evaluation of the BioFreedom™ Stent [Leaders Free]; NCT01623180). Topics: Acute Coronary Syndrome; Administration, Oral; Aged; Aged, 80 and over; Anticoagulants; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Double-Blind Method; Drug-Eluting Stents; Female; Hemorrhage; Humans; Kaplan-Meier Estimate; Male; Metals; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Proportional Hazards Models; Prosthesis Design; Risk Factors; Sirolimus; Stents; Time Factors; Treatment Outcome | 2017 |
2-Year Outcomes of High Bleeding Risk Patients After Polymer-Free Drug-Coated Stents.
A 1-year follow-up, polymer-free metallic stent coated with biolimus-A9 followed by 1-month dual antiplatelet therapy is safer and more effective than a bare-metal stent (BMS) for patients with high risk of bleeding.. This study analyzed 2-year outcomes to determine whether these benefits are maintained.. In a prospective, multicenter, double-blind trial, we randomized 2,466 high bleeding risk patients to receive a drug-coated stent (DCS) or a BMS followed by 1-month dual antiplatelet therapy. The primary safety endpoint was a composite of cardiac death, myocardial infarction, or stent thrombosis. The primary efficacy endpoint was clinically driven target lesion revascularization.. At 2 years, the primary safety endpoint had occurred in 147 DCS and 180 BMS patients (15.3%) (hazard ratio: 0.80; 95% confidence interval: 0.64 to 0.99; p = 0.039). Clinically driven target lesion revascularization occurred for 77 DCS and 136 BMS patients (12.0%) (hazard ratio: 0.54; 95% confidence interval: 0.41 to 0.72; p < 0.0001). Major bleeding occurred in 8.9% of DCS and 9.2% of BMS patients (p = 0.95), and a coronary thrombotic event (myocardial infarction and/or stent thrombosis) occurred in 8.2% of DCS and 10.6% of BMS patients (p = 0.045). One-year mortality was 27.1% for a major bleed and 26.3% for a thrombotic event. At 2 years, multivariate correlates of major bleeding were age >75 years, anemia, raised plasma creatinine, and planned long-term anticoagulation. Correlates of the primary safety endpoint were age, anemia, congestive heart failure, multivessel disease, number of stents implanted, and use of a BMS rather than a DCS.. Safety and efficacy benefits of DCS over BMS were maintained for 2 years in high bleeding risk patients. Rates of major bleeding and coronary thrombotic events were no different and were associated with a substantial and comparable mortality risk. (A Prospective Randomized Comparison of the BioFreedom Biolimus A9 Drug Coated Stent Versus the Gazelle Bare Metal Stent in Patients With High Risk of Bleeding [LEADERS FREE]; NCT01623180). Topics: Aged; Aged, 80 and over; Angioplasty, Balloon, Coronary; Coronary Disease; Coronary Thrombosis; Death; Double-Blind Method; Drug Therapy, Combination; Drug-Eluting Stents; Female; Hemorrhage; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Platelet Aggregation Inhibitors; Proportional Hazards Models; Prospective Studies; Risk; Sirolimus; Statistics as Topic; Stents; Survival Rate | 2017 |
Comparison of Durable-Polymer Zotarolimus-Eluting and Biodegradable-Polymer Biolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease: 3-Year Clinical Outcomes in the Randomized SORT OUT VI Trial.
The authors sought to compare the safety and efficacy of the biocompatible durable-polymer zotarolimus-eluting stent with the biodegradable-polymer biolimus-eluting stent in unselected coronary patients.. Biodegradable-polymer biolimus-eluting stents are superior to first-generation durable-polymer drug-eluting stents in long-term randomized all-comer trials. Long-term data comparing them to second-generation durable-polymer drug-eluting stents are lacking.. The study was a randomized, multicenter, all-comer, noninferiority trial in patients with chronic stable coronary artery disease or acute coronary syndromes and at least 1 coronary artery lesion requiring treatment with a drug-eluting stent. Endpoints included major adverse cardiac events (MACE), a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion) and efficacy (target lesion revascularization); the individual endpoints of MACE; all-cause mortality; any myocardial infarction; target vessel revascularization; and definite or probable stent thrombosis at 36 months.. From March 2011 to August 2012, 2,999 patients were randomly assigned (1:1) to receive either the zotarolimus-eluting (1,502 patients) or the biolimus-eluting (1,497 patients) stent. At 3-year follow-up, MACE occurred in 128 (8.6%) patients assigned to the durable-polymer zotarolimus-eluting stent and in 144 (9.6%) assigned to the biodegradable-polymer biolimus-eluting stent (p = 0.36). Occurrence of cardiac death (2.7% vs. 3.4%), myocardial infarction not clearly attributable to a non-target lesion (2.7% vs. 2.5%), and target lesion revascularization (5.4% vs. 5.5%) did not differ significantly between the 2 groups. Definite very late stent thrombosis occurred in 6 (0.4%) patients assigned to the durable-polymer zotarolimus-eluting stent and in 10 (0.7%) assigned to the biodegradable-polymer biolimus-eluting stent (p = 0.33).. At 3-year follow-up, the durable-polymer zotarolimus-eluting stent and the biodegradable-polymer biolimus-eluting stent were similar in clinical outcome, with no significant difference in safety and efficacy outcomes, including stent thrombosis. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Denmark; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Proportional Hazards Models; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2017 |
Long-term ticagrelor monotherapy versus standard dual antiplatelet therapy followed by aspirin monotherapy in patients undergoing biolimus-eluting stent implantation: rationale and design of the GLOBAL LEADERS trial.
The GLOBAL LEADERS trial is a superiority study in patients undergoing percutaneous coronary intervention, with a uniform use of Biolimus A9-eluting stents (BES) and bivalirudin. GLOBAL LEADERS was designed to assess whether a 24-month antithrombotic regimen with ticagrelor and one month of acetylsalicylic acid (ASA), compared to conventional dual antiplatelet therapy (DAPT), improves outcomes.. Patients (n >16,000) are randomised (1:1 ratio) to ticagrelor 90 mg twice daily for 24 months plus ASA ≤100 mg for one month versus DAPT with either ticagrelor (acute coronary syndrome) or clopidogrel (stable coronary artery disease) for 12 months plus ASA ≤100 mg for 24 months. The primary outcome is a composite of all-cause mortality or non-fatal, new Q-wave myocardial infarction at 24 months. The key safety endpoint is investigator-reported class 3 or 5 bleeding according to the Bleeding Academic Research Consortium (BARC) definitions. Sensitivity analysis will be carried out to explore potential differences in outcome across geographic regions and according to specific angiographic and clinical risk estimates.. The GLOBAL LEADERS trial aims to assess the role of ticagrelor as a single antiplatelet agent after a short course of DAPT for the long-term prevention of cardiac adverse events, across a wide spectrum of patients, following BES implantation. Topics: Acute Coronary Syndrome; Adenosine; Adolescent; Adult; Aged; Aged, 80 and over; Aspirin; Drug Combinations; Drug-Eluting Stents; Female; Hemorrhage; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Purinergic P2Y Receptor Antagonists; Sirolimus; Ticagrelor; Time; Treatment Outcome; Young Adult | 2016 |
First generation versus second generation drug-eluting stents for the treatment of bifurcations: 5-year follow-up of the LEADERS all-comers randomized trial.
Historically, percutaneous coronary intervention (PCI) of bifurcation lesions was associated with worse procedural and clinical outcomes when compared with PCI of non-bifurcation lesions. Newer generation drug-eluting stents (DES) might improve long-term clinical outcomes after bifurcation PCI.. The LEADERS trial was a 10-center, assessor-blind, non-inferiority, all-comers trial, randomizing 1,707 patients to treatment with a biolimus A9(TM) -eluting stent (BES) with an abluminal biodegradable polymer or a sirolimus-eluting stent (SES) with a durable polymer (ClinicalTrials.gov Identifier: NCT00389220). Five-year clinical outcomes were compared between patients with and without bifurcation lesions and between BES and SES in the bifurcation lesion subgroup. There were 497 (29%) patients with at least 1 bifurcation lesion (BES = 258; SES = 239). At 5-year follow-up, the composite endpoint of cardiac death, myocardial infarction (MI) and clinically-indicated (CI) target vessel revascularization (TVR) was observed more frequently in the bifurcation group (26.6% vs. 22.4%, P = 0.049). Within the bifurcation lesion subgroup, no differences were observed in (cardiac) death or MI rates between BES and SES. However, CI target lesion revascularization (TLR) (10.1% vs. 15.9%, P = 0.0495), and CI TVR (12.0% vs. 19.2%, P = 0.023) rates were significantly lower in the BES group. Definite/probable stent thrombosis (ST) rate was numerically lower in the BES group (3.1% vs. 5.9%, P = 0.15). Very late (>1 year) definite/probable ST rates trended to be lower with BES (0.4% vs. 3.1%, P = 0.057).. In the treatment of bifurcation lesions, use of BES led to superior long-term efficacy compared with SES. Safety outcomes were comparable between BES and SES, with an observed trend toward a lower rate of very late definite/probable ST between 1 and 5 years with the BES. © 2015 Wiley Periodicals, Inc. Topics: Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Europe; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2016 |
Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention: The SORT OUT VII Trial.
Coronary drug-eluting stents with biodegradable polymers have been designed to improve safety and efficacy.. The Scandinavian Organization for Randomized Trials With Clinical Outcome (SORT OUT) VII trial-a large-scale registry-based randomized, multicenter, single-blind, 2-arm, noninferiority trial-compared 2 biodegradable polymer drug-eluting stents: the thin-strut cobalt-chromium sirolimus-eluting Orsiro stent and the stainless steel biolimus-eluting Nobori stent in an all-comer patient population. The primary end point target lesion failure was a composite of cardiac death, myocardial infarction (not related to other than index lesion), or target lesion revascularization within 1 year, analyzed by intention to treat (noninferiority margin of 3.0%). Clinically driven event detection based on Danish registries was used. A total of 1261 patients were assigned to receive the sirolimus-eluting stent (1590 lesions) and 1264 patients to the biolimus-eluting stent (1588 lesions). At 1 year, the composite end point target lesion failure occurred in 48 patients (3.8%) in the sirolimus-eluting group and in 58 patients (4.6%) in the biolimus-eluting group (absolute risk difference, -0.78% [upper limit of 1-sided 95% confidence interval, 0.61%]; P<0.0001). Rates of definite stent thrombosis occurred in 5 (0.4%) of the sirolimus-eluting group compared with 15 (1.2%) biolimus-eluting stent-treated patients (rate ratio, 0.33; 95% confidence interval, 0.12-0.92; P=0.034), which largely was attributable to a lower risk of subacute definite stent thrombosis: 0.1% versus 0.6% (rate ratio, 0.12; 95% confidence interval, 0.02-1.00; P=0.05).. The thin-strut sirolimus-eluting Orsiro stent was noninferior to the biolimus-eluting Nobori stent in unselected patients for target lesion failure at 1 year.. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01879358. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Chromium Alloys; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Intention to Treat Analysis; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Registries; Risk Factors; Scandinavian and Nordic Countries; Single-Blind Method; Sirolimus; Stainless Steel; Time Factors; Treatment Outcome | 2016 |
Biolimus-eluting stent with biodegradable polymer improves clinical outcomes in patients with acute myocardial infarction.
To investigate clinical outcomes of coronary intervention using a biolimus-eluting stent (BES) compared with a sirolimus-eluting stent (SES) in patients with acute myocardial infarction (AMI) in the Limus Eluted from A Durable versus ERodable Stent (LEADERS) coating trial at the final 5-year follow-up.. The LEADERS trial is a multicentre all-comer study, where patients (n=1707) were randomised to percutaneous intervention with either BES containing biodegradable polymer or SES containing durable polymer. Out of 1707 patients enrolled in this trial, 573 patients had percutaneous coronary intervention for AMI (BES=280, SES=293) and were included in the current analysis. Patient-oriented composite endpoint (POCE, including all death, all myocardial infarction (MI) and all revascularisations), major adverse cardiac events (MACE, including cardiac death, MI and clinically indicated target vessel revascularisation) and stent thrombosis were assessed at 5-year follow-up.. The baseline clinical, angiographic and procedural characteristics were well matched between BES and SES groups. In all patients with AMI, coronary intervention with a BES, compared with SES, significantly reduced POCE (28.9% vs 42.3%; relative risk (RR) 0.61, 95% CI 0.47 to 0.82, p=0.001) at 5-year follow-up. There was also a reduction in MACE rate in the BES group (18.2% vs 25.9%; RR 0.67, 95% CI 0.47 to 0.95, p=0.025); however, there was no difference in cardiac death and stent thrombosis. In patients with ST-elevation MI (STEMI), coronary intervention with BES significantly reduced POCE (24.4% vs 39.3%; RR 0.55, 95% CI 0.36 to 0.85, p=0.006), MACE (12.6% vs 25.0%; RR 0.47, 95% CI 0.26 to 0.83, p=0.008) and cardiac death (3.0% vs 11.4%; RR 0.25, 95% CI 0.08 to 0.75, p=0.007), along with a trend towards reduction in definite stent thrombosis (3.7% vs 8.6%; RR 0.41, 95% CI 0.15 to 1.18, p=0.088), compared with SES.. BES, compared with SES, significantly improved safety and efficacy outcomes in patients with AMI, especially those with STEMI, at 5-year follow-up.. NCT 00389220. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Angiography; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Odds Ratio; Percutaneous Coronary Intervention; Polymers; Predictive Value of Tests; Prosthesis Design; Recurrence; Risk Assessment; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2015 |
Five-year clinical outcome of the Nobori drug-eluting coronary stent system in the treatment of patients with coronary artery disease: final results of the NOBORI 1 trial.
To assess the safety and performance of the Nobori drug-eluting stent with biodegradable polymer versus the TAXUS drug-eluting stent with permanent polymer, in the treatment of patients with de novo coronary artery lesions.. NOBORI 1 was a multicentre, randomised (2:1), prospective, controlled, clinical trial which enrolled 363 patients (238 Nobori and 125 TAXUS) with up to two de novo lesions in two epicardial vessels. The primary endpoint was in-stent late loss at nine months, while secondary endpoints included safety and efficacy up to five years. At five years, clinical data were available for 350 patients (96%). There were no differences in the composite of death and myocardial infarction (10.9% vs. 11.2%) and target lesion failure (9.2% and 10.4%), while ischaemia- and non-ischaemia-driven target lesion revascularisations were less frequent in the Nobori (6.3%) than in the TAXUS arm (16.0%). The rates of stent thrombosis (definite and probable according to the ARC definitions) were 0.0% and 3.2%, in the Nobori and TAXUS stents, respectively (p=0.014).. Five years after implantation, the Nobori DES resulted in durable treatment effects with very low TLR and no stent thrombosis. The study was not powered to assess the differences in clinical endpoints. These data are hypothesis-generating. Topics: Absorbable Implants; Aged; Coronary Artery Bypass; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Female; Graft Occlusion, Vascular; Humans; Male; Middle Aged; Mortality; Myocardial Infarction; Myocardial Revascularization; Percutaneous Coronary Intervention; Prosthesis Design; Sirolimus; Treatment Outcome | 2015 |
Clinical Impact of Intravascular Ultrasound-Guided Chronic Total Occlusion Intervention With Zotarolimus-Eluting Versus Biolimus-Eluting Stent Implantation: Randomized Study.
There have been no randomized studies comparing intravascular ultrasound (IVUS)-guided versus conventional angiography-guided chronic total occlusion (CTO) intervention using new-generation drug-eluting stent Therefore, we conducted a prospective, randomized, multicenter trial designed to test the hypothesis that IVUS-guided CTO intervention is superior to angiography-guided intervention.. After successful guidewire crossing, 402 patients with CTOs were randomized to the IVUS-guided group (n=201) or the angiography-guided group (n=201) and secondarily randomized to Resolute zotarolimus-eluting stents or Nobori biolimus-eluting stents. The primary and secondary end points were cardiac death and a major adverse cardiac event defined as the composite of cardiac death, myocardial infarction, or target-vessel revascularization, respectively. After 12-month follow-up, the rate of cardiac death was not significantly different between the IVUS-guided group (0%) and the angiography-guided group (1.0%; P by log-rank test=0.16). However, major adverse cardiac event rates were significantly lower in the IVUS-guided group than that in the angiography-guided group (2.6% versus 7.1%; P=0.035; hazard ratio, 0.35; 95% confidence interval, 0.13-0.97). Occurrence of the composite of cardiac death or myocardial infarction was significantly lower in the IVUS-guided group (0%) than in the angiography-guided group (2.0%; P=0.045). The rates of target-vessel revascularization were not significantly different between the 2 groups. In the comparison between Resolute zotarolimus-eluting stent and Nobori biolimus-eluting stent, major adverse cardiac event rates were not significantly different (4.0% versus 5.7%; P=0.45).. Although IVUS-guided CTO intervention did not significantly reduce cardiac mortality, this randomized study demonstrated that IVUS-guided CTO intervention might improve 12-month major adverse cardiac event rate after new-generation drug-eluting stent implantation when compared with conventional angiography-guided CTO intervention.. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01563952. Topics: Aged; Anti-Bacterial Agents; Coronary Angiography; Coronary Occlusion; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Random Allocation; Sirolimus; Ultrasonography, Interventional | 2015 |
Optical Coherence Tomography Guided Percutaneous Coronary Intervention With Nobori Stent Implantation in Patients With Non-ST-Segment-Elevation Myocardial Infarction (OCTACS) Trial: Difference in Strut Coverage and Dynamic Malapposition Patterns at 6 Mont
Incomplete strut coverage has been documented an important histopathologic morphometric predictor for later thrombotic events. This study sought to investigate whether optical coherence tomography (OCT)-guided percutaneous coronary intervention with Nobori biolimus-eluting stent implantation in patients with non-ST-segment-elevation myocardial infarction would provide improved strut coverage at 6 months in comparison with angiographic guidance only.. One hundred patients were randomized 1:1 to either OCT-guided or angio-guided Nobori biolimus-eluting stent implantation. Postprocedure OCT was performed in all patients. In the OCT-guided group, prespecified criteria indicating additional intervention were related to (1) stent underexpansion, (2) strut malapposition, (3) edge dissection(s), and (4) residual stenosis at the distal or proximal reference segment(s). A final OCT was performed in case of reintervention. Six-month OCT follow-up was available in 85 patients. Twenty-three (46%) OCT-guided patients had additional postdilation or stenting. The percentage of acutely malapposed struts was substantially lower in the OCT-guided group (3.4% [interquartile range, 0.3-7.6] versus 7.8% [interquartile range, 2.3-19.4]; P<0.01). At 6-month follow-up, the OCT-guided group had a significantly lower proportion of uncovered struts; 4.3% [interquartile range, 1.2-9.8] versus 9.0% [interquartile range, 5.5-14.5], P<0.01. Furthermore, OCT-guided patients had significantly more completely covered stents: 17.5% versus 2.2%, P=0.02. The percentages of malapposed struts and struts being both uncovered and malapposed at follow-up were comparable between groups.. OCT-guided optimization of Nobori biolimus-eluting stent implantation improves strut coverage at 6-month follow-up in comparison with angiographic guidance alone.. URL: http://www.clinicaltrials.gov. Unique identifier: NCT02272283. Topics: Aged; Angioplasty, Balloon, Coronary; Coronary Angiography; Drug-Eluting Stents; Electrocardiography; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Random Allocation; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2015 |
Metallic Limus-Eluting Stents Abluminally Coated with Biodegradable Polymers: Angiographic and Clinical Comparison of a Novel Ultra-Thin Sirolimus Stent Versus Biolimus Stent in the DESTINY Randomized Trial.
To evaluate the outcomes of patients treated with a new drug-eluting stent formulation with low doses of sirolimus, built in an ultra-thin-strut platform coated with biodegradable abluminal coating.. This study is a randomized trial that tested the main hypothesis that the angiographic late lumen loss of the novel sirolimus-eluting stent is noninferior compared with commercially available biolimus-eluting stent. A final study population comprising 170 patients with one or two de novo lesions was randomized in the ratio 2:1 for sirolimus-eluting stent or biolimus-eluting stent, respectively. The primary endpoint was 9-month angiographic in-stent late lumen loss. Adverse clinical events were prospectively collected for 1 year.. After 9 months, the novel sirolimus-eluting stent was shown noninferior compared with the biolimus stent for the primary endpoint (angiographic in-stent late lumen loss: 0.20 ± 0.29 mm vs. 0.15 ± 0.20 mm, respectively; P value for noninferiority <0.001). The 1-year incidence of death, myocardial infarction, repeat revascularization, and stent thrombosis remained low and not significantly different between the groups.. The present randomized trial demonstrates that the tested novel sirolimus-eluting stent was angiographically noninferior in comparison with a last-generation biolimus-eluting stent. Topics: Absorbable Implants; Aged; Brazil; Cardiovascular Agents; Coated Materials, Biocompatible; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome | 2015 |
Final 3-Year Outcome of a Randomized Trial Comparing Second-Generation Drug-Eluting Stents Using Either Biodegradable Polymer or Durable Polymer: NOBORI Biolimus-Eluting Versus XIENCE/PROMUS Everolimus-Eluting Stent Trial.
There is a paucity of data reporting the clinical outcomes of biodegradable polymer biolimus-eluting stent (BP-BES) compared with durable polymer everolimus-eluting stent (DP-EES) beyond 1 year after stent implantation when the polymer is fully degraded.. The NOBORI Biolimus-Eluting Versus XIENCE/PROMUS Everolimus-Eluting Stent Trial (NEXT) is a prospective, multicenter, randomized, open-label, noninferiority trial comparing BP-BES with DP-EES in patients scheduled for percutaneous coronary intervention using drug-eluting stent (DES) without any exclusion criteria among 98 participating centers in Japan. The trial was designed to evaluate noninferiority of BP-BES relative to DP-EES in terms of any target-lesion revascularization at 1 year and death or myocardial infarction at 3 years. Between May and October 2011, 3235 patients were randomly assigned to receive either BP-BES (1617 patients) or DP-EES (1618 patients). Complete 3-year follow-up was achieved in 97.6% of patients. At 3 years, the primary safety end point of death or myocardial infarction occurred in 159 patients (9.9%) in the BP-BES group and in 166 patients (10.3%) in the DP-EES group, demonstrating noninferiority of BP-BES relative to DP-EES (P noninferiority<0.0001 and P superiority=0.7). Cumulative incidence of target-lesion revascularization was not significantly different between the 2 groups (7.4% versus 7.1%; P=0.8). By a landmark analysis at 1 year, the cumulative incidences of death or myocardial infarction and target-lesion revascularization were also not significantly different between the 2 groups (4.6% versus 5.2%; P=0.46 and 3.3% versus 2.7%; P=0.39, respectively).. Safety and efficacy outcomes of BP-BES were non inferior to those of DP-EES 3 years after stent implantation.. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01303640. Topics: Absorbable Implants; Aged; Blood Vessel Prosthesis Implantation; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Japan; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Postoperative Complications; Prospective Studies; Sirolimus; Survival Analysis; Treatment Outcome | 2015 |
Comparison of everolimus-eluting and biolimus-eluting coronary stents with everolimus-eluting bioresorbable scaffold: study protocol of the randomized controlled EVERBIO II trial.
Second-generation everolimus-eluting stents (EES) and third generation biolimus-eluting stents (BES) have been shown to be superior to first-generation paclitaxel-eluting stents (PES) and second-generation sirolimus-eluting stents (SES). However, neointimal proliferation and very late stent thrombosis is still an unresolved issue of drug-eluting stent (DES) implantation overall. The Absorb™ (Abbott Vascular, Abbott Park, IL, USA) is the first CE approved DES with a bioresorbable vascular scaffold (BVS) thought to reduce long-term complication rates. The EVERBIO II trial was set up to compare the BVS safety and efficacy with both EES and BES in all patients viable for inclusion.. The EVERBIO II trial is a single-center, assessor-blinded, randomized trial. The study population consists of all patients aged≥18 years old undergoing percutaneous coronary intervention. Exclusion criterion is where the lesion cannot be treated with BVS (reference vessel diameter>4.0 mm). A total of 240 patients will be enrolled and randomly assigned into 3 groups of 80 with either BVS, EES or BES implantation. All patients will undergo a follow-up angiography study at 9 months. Clinical follow-up for up to 5 years will be conducted by telephone. The primary endpoint is in-segment late lumen loss at 9 months measured by quantitative coronary angiography. Secondary endpoints are patient-oriented major adverse cardiac event (MACE) (death, myocardial infarction and target-vessel revascularization), device-oriented MACE (cardiac death, myocardial infarction and target-lesion revascularization), stent thrombosis according to ARC and binary restenosis at follow-up 12 months angiography.. EVERBIO II is an independent, randomized study, aiming to compare the clinical efficacy, angiographic outcomes and safety of BVS, EES and BES in all comer patients.. The trial listed in clinicaltrials.gov as NCT01711931. Topics: Absorbable Implants; Cardiovascular Agents; Clinical Protocols; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Humans; Myocardial Infarction; Percutaneous Coronary Intervention; Prosthesis Design; Research Design; Sirolimus; Switzerland; Time Factors; Tissue Scaffolds; Treatment Outcome | 2014 |
Comparison of biolimus A9-eluting (Nobori) and everolimus-eluting (Promus Element) stents in patients with de novo native long coronary artery lesions: a randomized Long Drug-Eluting Stent V trial.
Procedural and clinical outcomes still remain unfavorable for patients with long coronary lesions who undergo percutaneous coronary intervention. The current study, therefore, evaluated 2 innovative drug-eluting stents for the management of long-lesion coronary artery disease.. This randomized, multicenter, prospective trial, called the Long Drug-Eluting Stent (LONG-DES) V trial, compared the biodegradable polymer-based biolimus A9-eluting stent (BES) and the durable polymer-based platinum chromium everolimus-eluting stent (PtCr-EES) in 500 patients with long (≥ 25 mm) coronary lesions. The primary end point of the trial was in-segment late luminal loss at the 9-month angiographic follow-up. The BES and PtCr-EES groups had similar baseline characteristics, with a slightly shorter lesion length in the BES group versus the PtCr-EES group (29.24 ± 12.17 versus 32.27 ± 13.84 mm; P = 0.016). In-segment late luminal loss was comparable between the 2 groups at the 9-month angiographic follow-up (BES, 0.14 ± 0.38 versus PtCr-EES, 0.11 ± 0.37 mm; difference, 0.031; 95% confidence interval, -0.053 to 0.091; P = 0.03 for a noninferiority margin of 0.11, P = 0.45 for superiority), as was in-stent late luminal loss (0.20 ± 0.41 versus 0.24 ± 0.38 mm; P = 0.29). The incidence of in-segment (6.1% versus 4.9%; P = 0.63) and in-stent (3.7% versus 4.9%; P = 0.59) binary restenosis was also similar between the groups. There was no significant between-group difference in the rate of composite outcome of death, myocardial infarction, and target vessel revascularization (41, 16.7% in BES versus 42, 16.5% in PtCr-EES; P=0.94).. BES and PtCr-EES implantation showed analogous angiographic and clinical outcomes for patients with de novo long coronary lesions.. http://www.clinicaltrials.gov. Unique identifier: NCT01186120. Topics: Aged; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Incidence; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Single-Blind Method; Sirolimus; Survival Rate; Thrombosis; Treatment Outcome | 2014 |
Biolimus-eluting stents with biodegradable polymer versus bare-metal stents in acute myocardial infarction: two-year clinical results of the COMFORTABLE AMI trial.
This study sought to determine whether the 1-year differences in major adverse cardiac event between a stent eluting biolimus from a biodegradable polymer and bare-metal stents (BMSs) in the COMFORTABLE trial (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST-Elevation Myocardial Infarction) were sustained during long-term follow-up.. A total of 1161 patients were randomly assigned to biolimus-eluting stent (BES) and BMS at 11 centers, and follow-up rates at 2 years were 96.3%. A subgroup of 103 patients underwent angiography at 13 months. At 2 years, differences in the primary end point of cardiac death, target-vessel myocardial infarction, and target lesion revascularization continued to diverge in favor of BES-treated patients (5.8%) compared with BMS-treated patients (11.9%; hazard ratio = 0.48; 95% confidence interval, 0.31-0.72; P < 0.001) with a significant risk reduction during the second year of follow-up (hazard ratio 1-2 years = 0.45; 95% confidence interval, 0.20-1.00; P = 0.049). Differences in the primary end point were driven by a reduction in target lesion revascularization (3.1% versus 8.2%; P < 0.001) and target-vessel reinfarction (1.3% versus 3.4%; P = 0.023). The composite of death, any reinfarction and revascularization (14.5% versus 19.3%; P = 0.03), and cardiac death or target-vessel myocardial infarction (4.2% versus 7.2%; P = 0.036) were less frequent among BES-treated patients compared with BMS-treated patients. The 13-month angiographic in-stent percent diameter stenosis amounted to 12.0 ± 7.2 in BES- and 39.6 ± 25.2 in BMS-treated lesions (P < 0.001).. Among patients with ST-segment-elevation myocardial infarction undergoing primary percutaneous coronary intervention, BES continued to improve cardiovascular events compared with BMS beyond 1 year.. http://www.clinicaltrials.gov. Unique identifier: NTC00962416. Topics: Aged; Coronary Angiography; Coronary Vessels; Death, Sudden, Cardiac; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Incidence; Longitudinal Studies; Male; Metals; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Recurrence; Sirolimus; Stents; Treatment Outcome | 2014 |
Study design and rationale of "a multicenter, open-labeled, randomized controlled trial comparing three 2nd-generation drug-eluting stents in real-world practice" (CHOICE trial).
The second-generation drug-eluting stents (DES) have shown superiority in many studies relating to safety and efficacy when compared with the first-generation DES. However, it is unclear whether there are differences in efficacy and safety among the second-generation DES after long-term follow-up.. This multicenter, prospective, randomized, open-labeled trial will directly compare the efficacy and safety among the patients treated with either everolimus-eluting stent (EES), zotarolimus-eluting stent with biolinx polymer (ZES-R), or biolimus-eluting stent (BES) with minimal exclusion criteria. The primary end point is a patient-oriented composite consisted of cardiac death, myocardial infarction not clearly attributable to a nontarget vessel and clinically indicated target lesion revascularization at 24-month clinical follow-up post-index procedure. With the hypothesis that "BES is non-inferior to EES" or "BES is non-inferior to ZES-R" in primary end point, approximately 2,600 patients will be assigned to one of the types of stents using a web-based randomization system.. The CHOICE trial will directly compare the efficacy and safety of EES, ZES-R, and BES in everyday clinical practice for long-term follow-up. Topics: Adult; Algorithms; Coronary Disease; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Myocardial Infarction; Prosthesis Design; Sirolimus | 2013 |
Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus
This study sought to report the final 5 years follow-up of the landmark LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial.. The LEADERS trial is the first randomized study to evaluate biodegradable polymer-based drug-eluting stents (DES) against durable polymer DES.. The LEADERS trial was a 10-center, assessor-blind, noninferiority, "all-comers" trial (N = 1,707). All patients were centrally randomized to treatment with either biodegradable polymer biolimus-eluting stents (BES) (n = 857) or durable polymer sirolimus-eluting stents (SES) (n = 850). The primary endpoint was a composite of cardiac death, myocardial infarction (MI), or clinically indicated target vessel revascularization within 9 months. Secondary endpoints included extending the primary endpoint to 5 years and stent thrombosis (ST) (Academic Research Consortium definition). Analysis was by intention to treat.. At 5 years, the BES was noninferior to SES for the primary endpoint (186 [22.3%] vs. 216 [26.1%], rate ratio [RR]: 0.83 [95% confidence interval (CI): 0.68 to 1.02], p for noninferiority <0.0001, p for superiority = 0.069). The BES was associated with a significant reduction in the more comprehensive patient-orientated composite endpoint of all-cause death, any MI, and all-cause revascularization (297 [35.1%] vs. 339 [40.4%], RR: 0.84 [95% CI: 0.71 to 0.98], p for superiority = 0.023). A significant reduction in very late definite ST from 1 to 5 years was evident with the BES (n = 5 [0.7%] vs. n = 19 [2.5%], RR: 0.26 [95% CI: 0.10 to 0.68], p = 0.003), corresponding to a significant reduction in ST-associated clinical events (primary endpoint) over the same time period (n = 3 of 749 vs. n = 14 of 738, RR: 0.20 [95% CI: 0.06 to 0.71], p = 0.005).. The safety benefit of the biodegradable polymer BES, compared with the durable polymer SES, was related to a significant reduction in very late ST (>1 year) and associated composite clinical outcomes. (Limus Eluted From A Durable Versus ERodable Stent Coating [LEADERS] trial; NCT00389220). Topics: Absorbable Implants; Aged; Cardiovascular Agents; Chi-Square Distribution; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Europe; Female; Humans; Intention to Treat Analysis; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Odds Ratio; Percutaneous Coronary Intervention; Polymers; Proportional Hazards Models; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2013 |
Biolimus-eluting biodegradable polymer-coated stent versus durable polymer-coated sirolimus-eluting stent in unselected patients receiving percutaneous coronary intervention (SORT OUT V): a randomised non-inferiority trial.
Third-generation biodegradable polymer drug-eluting stents might reduce the risk of stent thrombosis compared with first-generation permanent polymer drug-eluting stents. We aimed to further investigate the effects of a biodegradable polymer biolimus-eluting stent compared with a durable polymer-coated sirolimus-eluting stent in a population-based setting.. This randomised, multicentre, all-comer, non-inferiority trial was undertaken at three sites across western Denmark. Eligible patients were aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes, and at least one coronary artery lesion (>50% diameter stenosis). We randomly assigned patients (1:1) using an independently managed computer-generated allocation sequence to receive either a biolimus-eluting biodegradable polymer stent (Nobori, Terumo, Tokyo, Japan) or a sirolimus-eluting permanent polymer stent (Cypher Select Plus, Cordis, Johnson & Johnson, Warren, NJ, USA). The primary endpoint was a composite of safety (cardiac death, myocardial infarction, definite stent thrombosis) and efficacy (target vessel revascularisation) at 9 months, analysed by intention to treat (non-inferiority margin of 0·02). This trial is registered with ClinicalTrials.gov, number NCT01254981.. From July, 2009, to January, 2011, we assigned 1229 patients (1532 lesions) to receive the biolimus-eluting stent and 1239 (1555 lesions) to receive the sirolimus-eluting stent. One patient was lost to follow-up because of emigration. Intention-to-treat analysis showed that 50 (4·1%) patients who were assigned the biolimus-eluting stent and 39 (3·1%) who were assigned the sirolimus-eluting stent met the primary endpoint (risk difference 0·9% [upper limit of one-sided 95% CI 2·1%]; p(non-inferiority)=0·06). Significantly more patients in the biolimus-eluting stent group had definite stent thrombosis at 12 months than did those in the sirolimus-eluting stent group (9 [0·7%] vs 2 [0·2%], risk difference 0·6% [95% CI 0·0-1·1]; p=0·034). Per-protocol analysis showed that 45 (3·8%) of 1193 patients who received a biolimus-eluting stent and 39 (3·2%) of 1208 who received a sirolimus-eluting stent met the primary endpoint (risk difference 0·5% [upper limit of one-sided 95% CI 1·8%]; p(non-inferiority)=0·03).. At 1 year follow-up, the biodegradable polymer biolimus-eluting Nobori stent did not improve clinical results compared with a first-generation sirolimus-eluting stent. We will need to obtain long-term data before we can make recommendations for the role of this biolimus-eluting stent in routine clinical practice.. Terumo and Cordis (Johnson & Johnson). Topics: Absorbable Implants; Acute Coronary Syndrome; Aged; Aspirin; Coated Materials, Biocompatible; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Male; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Polymers; Retreatment; Sirolimus | 2013 |
Abluminal biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent (COMPARE II): a randomised, controlled, non-inferiority trial.
Drug-eluting stents with durable biocompatible or biodegradable polymers have been developed to address the risk of thrombosis associated with first-generation drug-eluting stents. We aimed to compare the safety and efficacy of a biodegradable polymer-coated biolimus-eluting stent with a thin-strut everolimus-eluting stent coated with a durable biocompatible polymer.. This open-label, prospective, randomised, controlled, non-inferiority trial was undertaken at 12 sites across Europe. We used limited exclusion criteria (age >18 years, life expectancy >5 years, reference vessel diameter 2·0-4·0 mm) to enrol patients eligible for percutaneous coronary intervention. Patients were randomly allocated (2:1) by computer-generated random numbers to receive either a biodegradable polymer biolimus-eluting stent (Nobori, Terumo, Tokyo, Japan) or a durable fluoropolymer-based everolimus-eluting stent (Xience V or Prime, Abbott Vascular, Santa Clara, CA, USA, or Promus, Boston Scientific, Natick, MA, USA). The primary endpoint was a composite of safety (cardiac death and non-fatal myocardial infarction) and efficacy (clinically indicated target vessel revascularisation) at 12 months, analysed by intention to treat. Patients received dual antiplatelet therapy for 12 months after discharge. The trial is registered with ClinicalTrials.gov, number NCT01233453.. From Jan 12, 2009, to Feb 7, 2011, we enrolled 2707 patients (4025 lesions), 1795 of whom were assigned to receive the biolimus-eluting stent (2638 lesions) and 912 to an everolimus-eluting stent (1387 lesions). 2688 (99·3%) patients completed 12 months' follow-up. Significantly more patients in the biolimus-eluting stent group received a non-assigned stent than did those in the everolimus-eluting stent group (105 [5·9%] vs 19 [2·1%]; p<0·0001). The primary endpoint occurred in 93 (5·2%) patients in the biolimus-eluting stent group and 44 (4·8%) patients in the everolimus-eluting stent group at 12 months (relative risk 1·07 [95% CI 0·75-1·52]; p(non-inferiority)<0·0001). Analysis per protocol did not change the outcome of this trial (p(non-inferiority)<0·0001).. Biodegradable polymer biolimus-eluting stents are as safe and efficacious as the current standard of a thin-strut everolimus-eluting stent with a durable biocompatible polymer. We need to follow-up patients for longer to show whether the biolimus-eluting stent reduces the risk of stent thrombosis after 1 year when compared with the everolimus-eluting stent.. Terumo Europe (Leuven, Belgium) and the Research Foundation of the Cardiology Department, Maasstad Hospital (Rotterdam, Netherlands). Topics: Absorbable Implants; Aspirin; Coated Materials, Biocompatible; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Materials Testing; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Polymers; Prospective Studies; Sirolimus | 2013 |
Randomized comparison of the Nobori biolimus A9-eluting stent with the sirolimus-eluting stent in patients with stenosis in native coronary arteries.
The aim of this randomized-controlled trial is to compare biolimus A9-eluting stent (Nobori) to sirolimus eluting stent (Cypher).. The Nobori coronary stent is coated only abluminally with a biodegradable polymer, poly-lactic acid, and the antiproliferative agent biolimus A9. This stent has been studied in randomized trials versus Taxus Express and Taxus Liberte and showed noninferiority and superiority for in-stent late loss. This is the first randomized trial of Nobori stent versus Cypher stent.. We conducted a randomized (3:2), controlled trial comparing Nobori and Cypher, in 335 patients (198 Nobori and 137 Cypher) at 15 centers in Japan. Patients with de-novo lesions in up to two native coronary arteries were considered for enrollment. The primary endpoint was freedom from target vessel failure (TVF), a composite of cardiac death, myocardial infarction, and target vessel revascularization at 9 months.. At 9 months, the primary endpoint of freedom from TVF was 92.6% in Nobori and 93.8% in Cypher arm (noninferiority test P < 0.001). As main secondary endpoints, the in-stent late loss was 0.12 ± 0.30 mm and 0.14 ± 0.34 mm in Nobori and Cypher stents, respectively. Target lesion revascularization was 0.5% in Nobori and 3.9% in Cypher treated patients (P = 0.04). Definite and probable stent thromboses were not recorded in any patient.. Despite the relatively small number of patients, this well controlled clinical trial confirmed the primary hypothesis of non-inferiority of the Nobori biolimus A9-eluting stent to the Cypher sirolimus-eluting stent for freedom from TVF. Both stents showed excellent midterm results. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Japan; Lactic Acid; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polyesters; Polymers; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome | 2012 |
Comparison of biolimus eluted from an erodible stent coating with bare metal stents in acute ST-elevation myocardial infarction (COMFORTABLE AMI trial): rationale and design.
Compared with bare metal stents (BMS), early generation drug-eluting stents (DES) reduce the risk of revascularisation in patients with ST-elevation myocardial infarction (STEMI) at the expense of an increased risk of very late stent thrombosis (ST). Durable polymer coatings for controlled drug release have been identified as a potential trigger for these late adverse events and this has led to the development of newer generation DES with durable and biodegradable polymer surface coatings with improved biocompatibility. In a recent all-comers trial, biolimus-eluting stents with a biodegradable polymer surface coating were found to reduce the risk of very late ST by 80% compared with sirolimus-eluting stents with durable polymer, which also translated into a lower risk of cardiac death and myocardial infarction (MI) beyond one year.. The multicentre COMFORTABLE AMI trial (NCT00962416) randomly assigned 1,161 patients to treatment with biolimus-eluting stents with biodegrable polymer and bare metal stents of otherwise identical design at 11 international sites. The primary endpoint is a composite of cardiac death, target-vessel MI and target lesion revascularisation at one year. Assuming a relative risk reduction of 40% in event rates of the primary endpoint in favour of biolimus-eluting stents with biodegradable polymer, 1,064 patients will provide 80% power to demonstrate superiority. Clinical follow-up will be continued through five years.. The COMFORTABLE AMI trial will determine whether biolimus-eluting stents with biodegradable polymer are superior to bare metal stents of otherwise identical design. This is the first randomised controlled trial (RCT) investigating DES with a biodegradable polymer surface coating for drug release in the treatment of patients with STEMI. Topics: Drug-Eluting Stents; Electrocardiography; Humans; Metals; Myocardial Infarction; Polymers; Research Design; Sirolimus | 2012 |
Effect of biolimus-eluting stents with biodegradable polymer vs bare-metal stents on cardiovascular events among patients with acute myocardial infarction: the COMFORTABLE AMI randomized trial.
The efficacy and safety of drug-eluting stents compared with bare-metal stents remains controversial in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI).. To compare stents eluting biolimus from a biodegradable polymer with bare-metal stents in primary PCI.. A prospective, randomized, single-blinded, controlled trial of 1161 patients presenting with STEMI at 11 sites in Europe and Israel between September 19, 2009, and January 25, 2011. Clinical follow-up was performed at 1 and 12 months.. Patients were randomized 1:1 to receive the biolimus-eluting stent (n = 575) or the bare-metal stent (n = 582).. Primary end point was the rate of major adverse cardiac events, a composite of cardiac death, target vessel-related reinfarction, and ischemia-driven target-lesion revascularization at 1 year.. Major adverse cardiac events at 1 year occurred in 24 patients (4.3%) receiving biolimus-eluting stents with biodegradable polymer and 49 patients (8.7%) receiving bare-metal stents (hazard ratio [HR], 0.49; 95% CI, 0.30-0.80; P = .004). The difference was driven by a lower risk of target vessel-related reinfarction (3 [0.5%] vs 15 [2.7%]; HR, 0.20; 95% CI, 0.06-0.69; P = .01) and ischemia-driven target-lesion revascularization (9 [1.6%] vs 32 [5.7%]; HR, 0.28; 95% CI, 0.13-0.59; P < .001) in patients receiving biolimus-eluting stents compared with those receiving bare-metal stents. Rates of cardiac death were not significantly different (16 [2.9%] vs 20 [3.5%], P = .53). Definite stent thrombosis occurred in 5 patients (0.9%) treated with biolimus-eluting stents and 12 patients (2.1%; HR, 0.42; 95% CI, 0.15-1.19; P = .10) treated with bare-metal stents.. Compared with a bare-metal stent, the use of biolimus-eluting stents with a biodegradable polymer resulted in a lower rate of the composite of major adverse cardiac events at 1 year among patients with STEMI undergoing primary PCI.. clinicaltrials.gov Identifier: NCT00962416. Topics: Absorbable Implants; Aged; Drug-Eluting Stents; Female; Humans; Male; Metals; Middle Aged; Myocardial Infarction; Myocardial Ischemia; Myocardial Reperfusion; Myocardial Revascularization; Polymers; Prospective Studies; Recurrence; Risk; Single-Blind Method; Sirolimus; Treatment Outcome | 2012 |
The outcome of bifurcation lesion stenting using a biolimus-eluting stent with a bio-degradable polymer compared to a sirolimus-eluting stent with a durable polymer.
This study investigated the differences in clinical outcomes between patients with bifurcation lesions (BL) treated with a biolimus-eluting stent (BES) with a biodegradable polymer, and a sirolimus-eluting stent (SES) with a durable polymer.. The clinical outcomes were assessed in the 497 patients (BES 258, SES 239) enrolled in the multicentre, randomised LEADERS trial who underwent treatment of ≥1 BL (total=534 BL). At 12-months follow-up there was no significant difference in the primary endpoint of MACE, a composite of cardiac death, myocardial infarction and clinically indicated target vessel revascularisation (BES 12.8% vs. SES 16.3%, p=0.31). Patients treated with BES had comparable rates of cardiac death (BES 2.7% vs. SES 2.9%, p=1.00), numerically higher rates of myocardial infarction (BES 8.9% vs. SES 5.4%, p=0.17), and significantly lower rates of clinically indicated target vessel revascularisation (4.3% vs. 11.3%, p=0.004) when compared to those treated with SES. The rate of stent thrombosis at 12-months was 4.3% and 3.8% for BES and SES, respectively (p=0.82).. In the treatment of BL the use of BES lead to superior efficacy and comparable safety compared to SES. Topics: Absorbable Implants; Acute Coronary Syndrome; Aged; Angioplasty, Balloon, Coronary; Coronary Artery Disease; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Polymers; Sirolimus; Treatment Outcome | 2011 |
2-year clinical follow-up from the randomized comparison of biolimus-eluting stents with biodegradable polymer and sirolimus-eluting stents with durable polymer in routine clinical practice.
This study sought to investigate safety and efficacy of biolimus-eluting stents (BES) with biodegradable polymer as compared with sirolimus-eluting stents (SES) with durable polymer through 2 years of follow-up.. BES with a biodegradable polymer provide similar efficacy and safety as SES with a durable polymer at 9 months. Clinical outcomes beyond the period of biodegradation of the polymer used for drug release and after discontinuation of dual antiplatelet therapy are of particular interest.. A total of 1,707 patients were randomized to unrestricted use of BES (n = 857) or SES (n = 850) in an all-comers patient population.. At 2 years, BES remained noninferior compared with SES for the primary endpoint, which was a composite of cardiac death, myocardial infarction, or clinically indicated target vessel revascularization (BES 12.8% vs. SES 15.2%, hazard ratio [HR]: 0.84, 95% confidence interval [CI]: 0.65 to 1.08, p(noninferiority) < 0.0001, p(superiority) = 0.18). Rates of cardiac death (3.2% vs. 3.9%, HR: 0.81, 95% CI: 0.49 to 1.35, p = 0.42), myocardial infarction (6.3% vs. 5.6%, HR: 1.12, 95% CI: 0.76 to 1.65, p = 0.56), and clinically indicated target vessel revascularization (7.5% vs. 8.6%, HR: 0.86, 95% CI: 0.62 to 1.20, p = 0.38) were similar for BES and SES. The rate of definite stent thrombosis through 2 years was 2.2% for BES and 2.5% for SES (p = 0.73). For the period between 1 and 2 years, event rates for definite stent thrombosis were 0.2% for BES and 0.5% for SES (p = 0.42). After discontinuation of dual antiplatelet therapy, no very late definite stent thrombosis occurred in the BES group.. At 2 years of follow-up, the unrestricted use of BES with a biodegradable polymer maintained a similar safety and efficacy profile as SES with a durable polymer. (Limus Eluted From a Durable Versus Erodable Stent Coating [LEADERS]; NCT00389220). Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chi-Square Distribution; Coronary Angiography; Coronary Artery Disease; Drug Therapy, Combination; Drug-Eluting Stents; Europe; Female; Follow-Up Studies; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Platelet Aggregation Inhibitors; Proportional Hazards Models; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Survival Rate; Thrombosis; Time Factors; Treatment Outcome | 2011 |
The three year follow-up of the randomised "all-comers" trial of a biodegradable polymer biolimus-eluting stent versus permanent polymer sirolimus-eluting stent (LEADERS).
The current study reports clinical outcomes at three year follow-up of the LEADERS clinical trial which was the first all-comers trial comparing a new generation biodegradable polymer biolimus drug-eluting stent (BES) with the first generation permanent polymer sirolimus-eluting stent (SES).. One thousand seven hundred and seven patients were randomised to unrestricted use of BES (n=857) or SES (n=850) in an all-comers population. Three year follow-up was available in 95% of the patients, 812 treated with BES and 809 treated with SES. At three years, BES remains non-inferior to SES for the primary endpoint of major adverse cardiac events (composite of cardiac death, myocardial infarction (MI), or clinically-indicated target vessel revascularisation (CI-TVR) (BES 15.7% versus SES 19%; HR 0.82 CI 0.65-1.03; p=0.09). The MACE Kaplan Meier event curves increasingly diverge with the difference in events increasing from 1.4% to 2.4% and 3.3% at 1, 2 and 3 years, respectively in favour of BES. The rate of cardiac death was non-significantly lower 4.2% versus 5.2% (HR=0.81 CI 0.52-1.26; p=0.34) and the rate of myocardial infarction was equivalent 7.2% versus 7.1% (HR 1.01 CI 0.70-1.44; p=0.97) for BES versus SES, respectively. Thus BES was non-inferior to SES in all the safety endpoints. Clinically-indicated TVR occurred in 9.4% of BES treated patients versus 11.1% of SES treated patients (HR 0.84 CI 0.62-1.13; p=0.25). Rates of definite stent thrombosis were 2.2% for BES and 2.9% for SES (HR 0.78 CI 0.43-1.43; p=0.43), with the event rate increase of 0.2% from one to three years for BES and 0.9% for SES. For patients presenting with ST-elevation myocardial infarction BES was superior to SES in reducing MACE.. The findings of the three year follow-up support the claim that the biodegradable polymer biolimus-eluting stent has equivalent safety and efficacy to permanent polymer sirolimus-eluting stent in an all-comers patient population. Its performance is superior in some subpopulations such as in ST-elevation MI patients and event rates for BES are overall lower than for SES with a trend toward increasing divergence of outcomes over three years. Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chi-Square Distribution; Coronary Artery Disease; Drug Therapy, Combination; Drug-Eluting Stents; Europe; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Platelet Aggregation Inhibitors; Polymers; Proportional Hazards Models; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2011 |
The impact of body mass index on the one year outcomes of patients treated by percutaneous coronary intervention with Biolimus- and Sirolimus-eluting stents (from the LEADERS Trial).
The aim of this analysis was to assess the effect of body mass index (BMI) on 1-year outcomes in patients enrolled in a contemporary percutaneous coronary intervention trial comparing a sirolimus-eluting stent with a durable polymer to a biolimus-eluting stent with a biodegradable polymer. A total of 1,707 patients who underwent percutaneous coronary intervention were randomized to treatment with either biolimus-eluting stents (n = 857) or sirolimus-eluting stents (n = 850). Patients were assigned to 1 of 3 groups according to BMI: normal (<25 kg/m(2)), overweight (25 to 30 kg/m(2)), or obese (>30 kg/m(2)). At 1 year, the incidence of the composite of cardiac death, myocardial infarction, and clinically justified target vessel revascularization was assessed. In addition, rates of clinically justified target lesion revascularization and stent thrombosis were assessed. Cox proportional-hazards analysis, adjusted for clinical differences, was used to develop models for 1-year mortality. Forty-five percent of the patients (n = 770) were overweight, 26% (n = 434) were obese, and 29% (n = 497) had normal BMIs. At 1-year follow-up, the cumulative rate of cardiac death, myocardial infarction, and clinically justified target vessel revascularization was significantly higher in the obese group (8.7% in normal-weight, 11.3% in overweight, and 14.5% in obese patients, p = 0.01). BMI (hazard ratio 1.47, 95% confidence interval 1.02 to 2.14, p = 0.04) was an independent predictor of stent thrombosis. Stent type had no impact on the composite of cardiac death, myocardial infarction, and clinically justified target vessel revascularization at 1 year in the 3 BMI groups (hazard ratio 1.08, 95% confidence interval 0.63 to 1.83, p = 0.73). In conclusion, BMI was an independent predictor of major adverse cardiac events at 1-year clinical follow-up. The higher incidence of stent thrombosis in the obese group may suggest the need for a weight-adjusted dose of clopidogrel. Topics: Aged; Angioplasty, Balloon, Coronary; Body Mass Index; Confidence Intervals; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Myocardial Infarction; Netherlands; Obesity; Odds Ratio; Overweight; Predictive Value of Tests; Proportional Hazards Models; Risk Factors; Sirolimus; Survival Analysis; Treatment Outcome | 2010 |
Biolimus-eluting biodegradable polymer versus sirolimus-eluting permanent polymer stent performance in long lesions: results from the LEADERS multicentre trial substudy.
Lesion length remains a predictor of target lesion revascularisation and results of long lesion stenting remain poor. Sirolimus-eluting stents have been shown to perform better than paclitaxel eluting stents in long lesions. In this substudy of the LEADERS trial, we compared the performance of biolimus biodegradable polymer (BES) and sirolimus permanent polymer stents (SES) in long lesions.. A total of 1,707 'all-comer' patients were randomly allocated to treatment with BES and SES. A stratified analysis of angiographic and clinical outcomes at nine months and one year, respectively was performed for vessels with lesion length <20 mm versus >20 mm (as measured by quantitative angiography).Of 1,707 patients, 592 BES patients with 831 lesions and 619 SES patients with 876 lesions had only short lesions treated. One hundred and fifty-three BES patients with 166 lesions and 151 SES patients with 162 lesions had long lesions. There were no significant differences in baseline clinical characteristics, except for higher number of patients with long lesions presenting with acute myocardial infarction in both stent groups. Long lesions tended to have lower MLD and greater percent diameter stenosis at baseline than short lesions. Late loss was greater for long lesions than short lesions. There was no statistically significant difference in late loss between BES and SES stents (0.32+/-0.69 vs 0.24+/-0.57, p=0.59). Binary in-segment restenosis was present in 23.2% versus 13.1% of long lesions treated with BES and SES, respectively (p=0.042). In patients with long lesions, the overall MACE rate was similar for BES and SES (17% vs 14.6%; p=0.62). There was a trend towards higher overall TLR rate with BES (12.4 % vs 6.0%; HR=2.06; p=0.07) and clinically driven TLR (10.5% vs 5.3%: HR 1.94; p=0.13). Rates of definite stent thrombosis were 3.3% in the long lesion group and 1.3-1.7 % in the short lesion group.. BES and SES appear similar with respect to MACE in long lesions in this "all-comer" patient population. However, long lesions tended to have a higher rate of binary in-segment restenosis and TLR following BES than SES treatment. Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Europe; Female; Humans; Male; Middle Aged; Myocardial Infarction; Polymers; Proportional Hazards Models; Prosthesis Design; Risk Assessment; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2009 |
Randomized comparison of the Nobori Biolimus A9-eluting coronary stent with the Taxus Liberté paclitaxel-eluting coronary stent in patients with stenosis in native coronary arteries: the NOBORI 1 trial--Phase 2.
The newly developed Nobori coronary stent coated with a bioresorbable polymer, polylactic acid, and the antiproliferative agent Biolimus A9 has the potential to reduce restenosis by suppressing neointima formation.. We conducted a randomized (2:1), controlled trial comparing the Biolimus A9-eluting stent Nobori and the paclitaxel-eluting stent Taxus Liberté, in 243 patients (153 Nobori and 90 Taxus) at 29 centers in Europe, Asia, and Australia. Patients with previously untreated lesions in up to 2 native coronary arteries were considered for enrollment. The primary end point was in-stent late loss at 9 months, whereas secondary end points included other quantitative coronary angiography parameters, such as in-segment late loss and the rate of restenosis as well as key intravascular ultrasound parameters. Clinical secondary end points were stent thrombosis and composite of major adverse cardiac events comprising death, myocardial infarction, and target vessel revascularization. At 9 months, the in-stent late loss was significantly lower in the Nobori group compared with the Taxus group (0.11+/-0.30 mm versus 0.32+/-0.50 mm) reaching both the primary hypothesis of noninferiority of Nobori stent versus Taxus Liberté stent (P<0.001) and the secondary hypothesis of superiority (P=0.001). This finding was confirmed by a significant reduction in binary restenosis from 6.2% in Taxus to 0.7% in Nobori (P=0.02) and neointimal volume obstruction, detected by intravascular ultrasound, from 5.5+/-7.2% in Taxus to 1.8+/-5.2% in Nobori (P=0.01). The major adverse cardiac events rate was 4.6% in the Nobori and 5.6% in the Taxus cohort of patients. The stent thrombosis rate was 0% in the Nobori arm and 4.4% in the Taxus arm.. The NOBORI 1 clinical trial confirmed its primary hypothesis--noninferiority of the Nobori Biolimus A9-eluting stent versus the Taxus Liberté stent in reducing neointimal proliferation. Both stents showed a low major adverse cardiac events rate in the studied population. Topics: Angioplasty, Balloon, Coronary; Asia; Australia; Cardiovascular Agents; Cell Proliferation; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Coronary Vessels; Drug-Eluting Stents; Europe; Female; Humans; Hyperplasia; Male; Middle Aged; Myocardial Infarction; Paclitaxel; Prospective Studies; Risk Assessment; Sirolimus; Thrombosis; Time Factors; Treatment Outcome; Ultrasonography, Interventional | 2009 |
24 other study(ies) available for umirolimus and Myocardial-Infarction
Article | Year |
---|---|
Polymer-free biolimus-A9-eluting stent performance according to renal impairment: insights from the RUDI-FREE registry.
Patients with chronic kidney disease (CKD) are at increased risk of cardiovascular disease and have a worse prognosis after percutaneous coronary interventions (PCI). The BioFreedom polymer-free biolimus-A9-eluting stent (PF-BES) has shown promising results in patients at high bleeding risk; however, its performance in CKD patients has yet to be analyzed.. The all-comers RUDI-FREE registry documented patients undergoing PCI with PF-BES in routine clinical practice. Patients were stratified into three groups according to their estimated glomerular filtration rate (eGFR): preserved renal function, mild renal insufficiency (RI), and with moderate to severe RI (eGFR ≥ 90, between 90 and 45, and <45 ml/min/1.73 m2, respectively). The primary safety end point was a patient-oriented composite end point of cardiovascular death, myocardial infarction (MI), and definite or probable stent thrombosis (ST). The primary efficacy end point was target lesion revascularization (TLR).. The registry documented 1,104 consecutive patients treated with PF-BES: 258 (23.4%) with preserved renal function, whereas 712 (64.7%) and 131 (11.9%) had mild and moderate to severe RI, respectively. At 1 year, the primary safety end point was significantly higher in patients with moderate to severe RI (3.5% vs. 2.8% vs. 11.5%; P < 0.001). Conversely, TLR proved similar among groups (0.4% vs. 1.8% vs. 0.8%; P = 0.235).. Patients with worse renal function had increased risk of the composite of cardiovascular deaths, MI, and definite or probable ST. However, the PF-BES showed similar efficacy despite differences in renal function. These findings need to be confirmed in large-scale randomized trials. Topics: Aged; Cardiovascular Diseases; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Registries; Renal Insufficiency, Chronic; Sirolimus; Thrombosis | 2022 |
Thin Strut CoCr Biodegradable Polymer Biolimus A9-Eluting Stents versus Thicker Strut Stainless Steel Biodegradable Polymer Biolimus A9-Eluting Stents: Two-Year Clinical Outcomes.
While thinner struts are associated with improved clinical outcomes in bare-metal stents (BMS), reducing strut thickness may affect drug delivery from drug-eluting stents (DES) and there are limited data comparing otherwise similar thin and thick strut DES. We assessed 2-year outcomes of patients treated with a thin strut (84-88um) cobalt-chromium, biodegradable polymer, Biolimus A9-eluting stent (CoCr-BP-BES) and compared these to patients treated with a stainless steel, biodegradable polymer, Biolimus A9-eluting stent (SS-BP-BES).. In total, 1257 patients were studied: 400 patients from 12 centres receiving ≥1 CoCr-BP-BES in the prospective Biomatrix Alpha registry underwent prespecified comparison with 857 patients who received ≥1 Biomatrix Flex SS-BP-BES in the LEADERS study (historical control). The primary outcome was major adverse cardiac events (MACE)-cardiac death, myocardial infarction (MI), or clinically driven target vessel revascularization (cd-TVR). Propensity analysis was used to adjust for differences in baseline variables and a landmark analysis at day-3 to account for differences in periprocedural MI definitions.. At 2-year follow-up, propensity-adjusted analysis showed the thin strut (84-88um) Biomatrix Alpha CoCr-BP-BES was associated with improved clinical outcomes compared with the thicker strut (114-120um) Biomatrix Flex SS-BP-BES. Topics: Absorbable Implants; Acute Coronary Syndrome; Aged; Anti-Inflammatory Agents; Chromium Alloys; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Registries; Sirolimus; Stainless Steel; Treatment Outcome | 2021 |
Comparative Effectiveness and Safety of Polymer-Free Biolimus-Eluting Stent and Durable Polymer Everolimus-Eluting Stent in All-Comer Patients Who Underwent Percutaneous Coronary Interventions.
We aim to compare Polymer-Free Biolimus-Eluting Stent (PF-BES) with Durable Polymer Everolimus-Eluting stent (DP-EES) in unselected patients. PF-BES showed a favorable profile in high-bleeding risk patients who underwent percutaneous coronary intervention. Limited data are available on PF-BES compared with second-generation durable polymer-coated drug-eluting stents in patients eligible for standard dual antiplatelet therapy. A total of 848 consecutive patients were enrolled: 306 patients were treated with PF-BES and 542 with DP-EES. Stent performance was tested in a propensity score-matched population and in a Complex Higher-Risk and Indicated Patients (CHIP) subpopulation. A per-lesion analysis on 1,204 lesions (PF-BES = 424 vs DP-EES = 780) was also performed. At a medium follow-up of 18.5 ± 5.0 months, no differences in the matched population were found in terms of major adverse cardiac events (PF-BES 9.0% vs DP-EES 4.5%; p 0.091), myocardial infarction (PF-BES 6.2% vs DP-EES 2.3%; p 0.111), stent restenosis (PF-BES 2.3% vs DP-EES 0.0%; p 0.123), definite or probable stent thrombosis (PF-BES 2.8% vs DP-EES 1.1%; p 0.448). A significant inferior rate of restenosis was observed in the DP-EES arm in the whole (PF-BES 2.3% vs DP-EES 0.6%; p 0.041) and CHIP populations (PF-BES 4.3% vs DP-EES 0.5%; p 0.023), as well as in the per-lesion analysis (DP-EES 0.4% vs PF-BES 1.7%; p 0.039). In conclusion, in a real-world cohort PF-BES performed similarly to DP-EES in terms of restenosis and stent thrombosis in the matched population. Nonetheless, in the whole and CHIP populations, as well as in the per-lesion analysis, restenosis occurrence resulted higher in the PF-BES group. Topics: Absorbable Implants; Aged; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Sirolimus; Treatment Outcome | 2019 |
Effects of Coronary Artery Revascularization with a Polymer-Free Biolimus A9-Coated BioFreedom Stent Versus Bypass Surgery before Noncardiac Surgery.
The present study aimed to evaluate the efficacy and safety of polymer-free drug-coated BioFreedom stent implantation in comparison to coronary artery bypass graft (CABG) before major noncardiac surgery.. In a multicenter registry, 55 patients required revascularization before major noncardiac surgery that should not be delayed >6 months. Of them, 27 underwent BioFreedom stent implantation and 28 underwent CABG. Primary outcomes included rate of noncardiac surgery, time from revascularization to noncardiac surgery, and occurrence of composite outcomes (all-cause death, myocardial infarction, stent thrombosis, stroke, repeat revascularization, or major bleeding).. The rate of major noncardiac surgery was significantly higher in the BioFreedom group (92.6%) than in the CABG group (64.3%; p=0.027). Time from revascularization to noncardiac surgery was significantly shorter in the BioFreedom group (38.0 days) than in the CABG group (73.0 days; p=0.042). During the hospitalization for revascularization period, the occurrence of primary outcomes did not differ between the groups. However, the BioFreedom group showed a shorter hospitalization period and lower total treatment cost than the CABG group. During the hospital stay for noncardiac surgery, the occurrence of composite outcome was not significantly different between groups (4% vs. 0%; p>0.999): stroke occurred in only 1 case, and there were no cases of death or stent thrombosis in the BioFreedom group.. This study demonstrated that BioFreedom stenting as a revascularization strategy before major noncardiac surgery might be feasible and safe in selected patients with less severe coronary artery diseases. Topics: Aged; Coronary Artery Bypass; Coronary Artery Disease; Drug-Eluting Stents; Female; Hemorrhage; Humans; Male; Middle Aged; Myocardial Infarction; Sirolimus; Stroke; Treatment Outcome | 2018 |
Mid-term outcome of biolimus-eluting stents with biodegradable polymer: results from a multinational prospective 'all-comers' registry.
The Nobori biolimus-eluting stent (BES) is a biodegradable polymer drug-eluting stent (DES). Several studies have shown its noninferiority in comparison with durable polymer DES.. We sought to investigate the efficacy and the safety of Nobori BES in an all-comer population undergoing a percutaneous coronary intervention.. A total of 12 912 patients with 19 947 coronary lesions, undergoing percutaneous coronary intervention with Nobori BES implantation at 200 centres around the world between August 2010 and December 2015, were included in this prospective registry. Patients were stratified into four groups according to the total stent length, with cutoffs at 18, 24 and 28 mm. The primary endpoint was the occurrence of major adverse cardiac events defined as the composite of cardiac death, target vessel myocardial infarction and clinically driven target lesion revascularization at 1 year.. At 1 year, the major adverse cardiac events rate was the highest (4.6%) in the fourth quartile of stent length (>28 mm), whereas the overall rate of the primary endpoint in the all cohort was 3.5%. Both target lesion revascularization and target vessel revascularization rates were significantly higher in patients with longer stent length was implanted (all P<0.05). The incidence of definite and probable stent thrombosis at 1 year was 0.5% in all cohort and similar across the four groups (varying from 0.4 to 0.7%, all P=NS).. Our data confirmed the efficacy and the safety of the Nobori BES in routine clinical practice. Longer stent length is associated with a higher risk of adverse cardiac events, and yet, this risk is comparable with that of other DES. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Prosthesis Design; Registries; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2017 |
Long-term Safety and Efficacy of New-Generation Drug-Eluting Stents in Women With Acute Myocardial Infarction: From the Women in Innovation and Drug-Eluting Stents (WIN-DES) Collaboration.
Women with acute myocardial infarction (MI) undergoing mechanical reperfusion remain at increased risk of adverse cardiac events and mortality compared with their male counterparts. Whether the benefits of new-generation drug-eluting stents (DES) are preserved in women with acute MI remains unclear.. To investigate the long-term safety and efficacy of new-generation DES vs early-generation DES in women with acute MI.. Collaborative, international, individual patient-level data of women enrolled in 26 randomized clinical trials of DES were analyzed between July and December 2016. Only women presenting with an acute coronary syndrome were included. Study population was categorized according to presentation with unstable angina (UA) vs acute MI. Acute MI included non-ST-segment elevation MI (NSTEMI) or ST-segment elevation MI (STEMI).. Randomization to early- (sirolimus- or paclitaxel-eluting stents) vs new-generation (everolimus-, zotarolimus-, or biolimus-eluting stents) DES.. Composite of death, MI or target lesion revascularization, and definite or probable stent thrombosis at 3-year follow-up.. Overall, the mean age of participants was 66.8 years. Of 11 577 women included in the pooled data set, 4373 (37.8%) had an acute coronary syndrome as clinical presentation. Of these 4373 women, 2176 (49.8%) presented with an acute MI. In women with acute MI, new-generation DES were associated with lower risk of death, MI or target lesion revascularization (14.9% vs 18.4%; absolute risk difference, -3.5%; number needed to treat [NNT], 29; adjusted hazard ratio, 0.78; 95% CI, 0.61-0.99), and definite or probable stent thrombosis (1.4% vs 4.0%; absolute risk difference, -2.6%; NNT, 46; adjusted hazard ratio, 0.36; 95% CI, 0.19-0.69) without evidence of interaction for both end points compared with women without acute MI (P for interaction = .59 and P for interaction = .31, respectively). A graded absolute benefit with use of new-generation DES was observed in the transition from UA, to NSTEMI, and to STEMI (for death, MI, or target lesion revascularization: UA, -0.5% [NNT, 222]; NSTEMI, -3.1% [NNT, 33]; STEMI, -4.0% [NNT, 25] and for definite or probable ST: UA, -0.4% [NNT, 278]; NSTEMI, -2.2% [NNT, 46]; STEMI, -4.0% [NNT, 25]).. New-generation DES are associated with consistent and durable benefits over 3 years in women presenting with acute MI. The magnitude of these benefits appeared to be greater per increase in severity of acute coronary syndrome. Topics: Acute Coronary Syndrome; Aged; Angina, Unstable; Antineoplastic Agents, Phytogenic; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Middle Aged; Mortality; Myocardial Infarction; Myocardial Revascularization; Non-ST Elevated Myocardial Infarction; Paclitaxel; Percutaneous Coronary Intervention; Proportional Hazards Models; Randomized Controlled Trials as Topic; Recurrence; Sirolimus; ST Elevation Myocardial Infarction; Treatment Outcome | 2017 |
Clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents versus durable polymer everolimus-eluting Xience stents.
There are limited data about clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents (BP-BES) and durable polymer everolimus-eluting Xience stents (DP-EES) in real world practice. We sought to compare the clinical outcomes of BP-BES and DP-EES in real world cohorts of patients undergoing percutaneous coronary intervention. A prospective multicenter registry enrolled 999 patients treated with BP-BES and 1,000 patients treated with DP-EES. The primary outcome was target lesion failure, defined as a composite of cardiac death, target vessel-related myocardial infarction, or target lesion revascularization. Definite or probable stent thrombosis was also compared in total and propensity score-matched cohorts. The median follow-up duration was 24 months, and mean age was 65 years (interquartile range, 56-72 years). Patients receiving BP-BES had a lower prevalence of acute coronary syndrome, prior myocardial infarction, multi-vessel disease, bifurcation lesions, and left anterior descending artery lesions than those receiving DP-EES. After propensity score matching (692 pairs), target lesion failure occurred in 22 patients receiving BP-BES and in 25 patients receiving DP-EES (3.2% versus 3.6%; adjusted hazard ratio [HR], 0.92; 95% confidence interval [CI], 0.53 to 1.60; p = 0.77). The risk of definite or probable stent thrombosis did not differ between the 2 groups (0.4% versus 0.4%; adjusted HR, 1.03; 95% CI, 0.21 to 4.98; p = 0.97). The results were consistent across various subgroups. In the propensity score-matched analysis of real world cohorts, BP-BES showed similar clinical outcomes compared to DP-EES. We need to investigate about whether differences in clinical outcome emerge during long-term follow-up. Topics: Absorbable Implants; Aged; Coated Materials, Biocompatible; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Propensity Score; Proportional Hazards Models; Prospective Studies; Sirolimus; Thrombosis; Treatment Outcome | 2017 |
Outcomes of Acute Myocardial Infarction Patients Implanted With Biodegradable Polymer Biolimus-Eluting Stents Versus New-Generation Durable Polymer Drug-Eluting Stents: A Retrospective Analysis.
We compared outcomes between biodegradable polymer biolimus-eluting stent (BP-BES) and new-generation durable polymer drug-eluting stent (DP-DES) implantations in patients with acute myocardial infarction (MI). Among 13472 patients with acute MI in a nationwide registry, 557 (64.8%) were in the BP-BES and 303 (35.2%) in the new-generation DP-DES group following coronary reperfusion. The occurrence of major adverse cardiac events (MACE; death, MI, revascularization) and stent thrombosis was compared. Major adverse cardiac events occurred in 53 (6.2%) patients and showed similar rates between the BP-BES and new-generation DP-DES groups (all: 6.6% vs 5.9%, P = .652; propensity score [PS] matched: n = 380, 6.3% vs 5.3%, P = .623). Stent thrombosis did not differ between groups (all: 0.3% vs 0.4%, P = .892; PS matched: 0.5% vs 0.5%, P = 1.000). Major adverse cardiac event-free survival was comparable between groups (all: 93.4% vs 94.1%, log-rank P = .357; PS matched: 93.7% vs 94.7%, log-rank P = .445). Biodegradable polymer biolimus-eluting stent was not associated with MACE (all: hazard ratio [HR], 1.67; 95% confidence interval [CI], 0.75-3.74; P = 0.212; PS matched: HR, 1.05; 95% CI, 0.40-2.75; P = .915). In conclusion, in patients with acute MI, BP-BES was equivalent to the new-generation DP-DES in terms of outcomes. Topics: Aged; Anti-Inflammatory Agents; Biocompatible Materials; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Propensity Score; Registries; Republic of Korea; Retrospective Studies; Sirolimus; Survival Rate; Treatment Outcome | 2017 |
One-year outcome from an all-comers population of patients with ST-segment elevation myocardial infarction treated with biolimus-eluting stent with biodegradable polymer.
To evaluate the performance of biolimus-eluting stent (BES) in patients with ST-elevation myocardial infarction (STEMI) undergoing percutaneous coronary intervention (PCI) in a real world clinical scenario.. Randomized studies suggest that the BES with biodegradable polymer is more effective and safe than early generation coronary stents in patients with STEMI.. We included all consecutive STEMI patients undergoing PCI in this prospective, multicenter registry. The primary endpoint of the study was the rate of major adverse cardiac events (MACE), a composite of cardiac death, recurrent myocardial infarction and ischemia-driven target vessel revascularization at 1-year follow-up.. Between June and December 2012 we enrolled 311 STEMI patients. The primary endpoint occurred in 3.2% (95% confidence interval: 1.6-5.8) of patients: cardiac death, re-infarction, and ischemia-driven TVR occurred in 2.3%, 1.3%, and 0.6% of patients, respectively. One-year MACE-free survival was 96.8% ± 1.0%.. In a real-world cohort of STEMI patients undergoing PCI, the use of BES is associated with good 1-year clinical outcome. These results confirm and expand previous findings showing the efficacy and safety of BES in the setting of randomized trials. Topics: Aged; Cardiovascular Agents; Disease-Free Survival; Drug-Eluting Stents; Female; Humans; Italy; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Recurrence; Registries; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2015 |
Biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent in patients with acute myocardial infarction.
There are limited data about long-term outcomes for biodegradable polymer biolimus-eluting stent (BES) versus durable polymer everolimus-eluting stent (EES) in patients undergoing percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI). We sought to compare the two-year efficacy and safety of BES versus EES in AMI patients.. A total of 707 consecutive patients with ST-segment elevation myocardial infarction and non-ST-segment elevation myocardial infarction who underwent PCI with BES (n=171) or EES (n=536) between July 2008 and June 2012 were enrolled in this study. The efficacy endpoint (target vessel failure; a composite of cardiac death, target vessel-related myocardial infarction, and target vessel revascularization) and the safety endpoint (a composite of all cause death, myocardial infarction, and stent thrombosis) at two years were compared in crude and propensity score-matched cohorts.. After two years, target vessel failure occurred in 13 patients treated with BES and 49 patients treated with EES (7.6% versus 9.1%; adjusted hazard ratio [HR], 1.09; 95% confidence interval [CI], 0.58-2.04; p=0.78). The rates of composite safety endpoint at two years were not different between two groups (BES 7.6% versus EES 10.8%; adjusted HR, 0.87; 95% CI, 0.47-1.62; p=0.66). The rates of stent thrombosis did not differ between two groups (BES 0.6% versus EES 1.3%; adjusted HR, 0.63; 95% CI, 0.06-6.20; p=0.69). These findings were substantiated by similar results in the propensity score-matched cohort.. In the treatment of patients with AMI, BES showed similar efficacy and safety compared to those of EES for up to two years. Topics: Absorbable Implants; Aged; Aspirin; Clopidogrel; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Sirolimus; Ticlopidine; Treatment Outcome | 2015 |
Outcomes following implantation of the Biolimus A9-eluting BioMatrix coronary stent: Primary analysis of the e-BioMatrix registry.
To assess the safety and efficacy of Biolimus A9-eluting stents (BES, BioMatrix™ and BioMatrix Flex™) in routine clinical practice.. The LEADERS randomized trial has documented equivalent efficacy and superior safety of the BES when compared to a first generation Sirolimus-eluting Cypher(TM) stent.. 5,472 patients from 57 centers, treated with BES, were enrolled in an international multicenter registry and followed clinically up to 2 years.. Mean patient age was 63.2 ± 11 years, 24% of patients had diabetes, and 49.8% presented with an acute coronary syndrome. 99.3% of patients were discharged on dual antiplatelet therapy (DAPT), 83.3% remained on DAPT at 1 year and 30.6% at 2 years. The incidence of the composite primary end point [major adverse cardiac events (MACE) at 12 months] was 4.5% [cardiac death 0.9%, myocardial infarction 1.7%, clinically indicated target vessel revascularization (ci-TVR) 2.8%]. MACE incidence was 6.8% at 24 months (cardiac death 1.5%, myocardial infarction 2.4%, ci-TVR 4.3%). At 12 months, 32 patients (0.6%) had suffered at least one definite or probable stent thrombosis (ST), and 91 patients (1.7%) a major bleed (MB). Nine patients with ST (27.3%) and 7 patients with a MB (7.7%) died during the first year after the index procedure. Between 12 and 24 months after implantation, there were 18 (0.4%) additional MB and 8 (0.2%) additional ST.. This large international cohort documents a low 12 and 24 months MACE incidence and a very low ST incidence in an unselected patient population undergoing BES implantation. The results are in keeping with those of the randomized controlled LEADERS trial. Even though ST with this stent was a rare event, it was still associated with significant mortality. MB remains a problem, and warrants improved tailoring of DAPT in recipients of drug eluting stents. Topics: Aged; Cardiovascular Agents; Comorbidity; Coronary Artery Disease; Coronary Thrombosis; Drug Therapy, Combination; Drug-Eluting Stents; Female; Humans; Incidence; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Proportional Hazards Models; Registries; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2015 |
Long-term safety and feasibility of three-vessel multimodality intravascular imaging in patients with ST-elevation myocardial infarction: the IBIS-4 (integrated biomarker and imaging study) substudy.
We assessed the feasibility and the procedural and long-term safety of intracoronary (i.c) imaging for documentary purposes with optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in patients with acute ST-elevation myocardial infarction (STEMI) undergoing primary PCI in the setting of IBIS-4 study. IBIS4 (NCT00962416) is a prospective cohort study conducted at five European centers including 103 STEMI patients who underwent serial three-vessel coronary imaging during primary PCI and at 13 months. The feasibility parameter was successful imaging, defined as the number of pullbacks suitable for analysis. Safety parameters included the frequency of peri-procedural complications, and major adverse cardiac events (MACE), a composite of cardiac death, myocardial infarction (MI) and any clinically-indicated revascularization at 2 years. Clinical outcomes were compared with the results from a cohort of 485 STEMI patients undergoing primary PCI without additional imaging. Imaging of the infarct-related artery at baseline (and follow-up) was successful in 92.2% (96.6%) of patients using OCT and in 93.2% (95.5%) using IVUS. Imaging of the non-infarct-related vessels was successful in 88.7% (95.6%) using OCT and in 90.5% (93.3%) using IVUS. Periprocedural complications occurred <2.0% of OCT and none during IVUS. There were no differences throughout 2 years between the imaging and control group in terms of MACE (16.7 vs. 13.3%, adjusted HR1.40, 95% CI 0.77-2.52, p = 0.27). Multi-modality three-vessel i.c. imaging in STEMI patients undergoing primary PCI is consistent a high degree of success and can be performed safely without impact on cardiovascular events at long-term follow-up. Topics: Aged; Cardiovascular Agents; Coronary Vessels; Drug-Eluting Stents; Europe; Feasibility Studies; Female; Humans; Male; Metals; Middle Aged; Multimodal Imaging; Myocardial Infarction; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2015 |
Comparison of Biolimus- and Everolimus-eluting stents in terms of clinical outcomes in patients with acute myocardial infarction: Results from the Korea Working Group on Myocardial Infarction (KorMI) Registry.
Topics: Aged; Drug Evaluation; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Mortality; Myocardial Infarction; Prognosis; Registries; Retrospective Studies; Sirolimus; Treatment Outcome | 2015 |
Comparison of First- and Second-Generation Drug-Eluting Stents in an All-Comer Population of Patients with Diabetes Mellitus (from Katowice-Zabrze Registry).
This study compared safety and efficacy of first- and second-generation DES in an unrestricted, real-life population of diabetic patients undergoing PCI.. The study was a subanalysis of diabetic patients from the all-comer Katowice-Zabrze Registry of patients undergoing PCI with the implantation of either first- (Paclitaxel-, Sirolimus-eluting stents) or second-generation DES (Zotarolimus-, Everolimus-, Biolimus-eluting stents). Efficacy defined as major adverse cardiac and cerebrovascular events (MACCE: death, myocardial infarction, target vessel revascularization, stroke) and safety defined as stent thrombosis (ST) were evaluated at 1 year.. From the total of 1916 patients, 717 were diabetics. Among them, 257 (36%) were treated with first-generation DES (230 [89%] Paclitaxel-eluting stents, 27 [11%] Sirolimus-eluting stents), 460 with second-generation DES (171 [37%] Zotarolimus-eluting stents, 243 [53%] Everolimus-eluting stents, 46 [10%] Biolimus-eluting stents). Rate of MACCE was equal in both groups (p=0.54). Second-generation DES had a better safety profile than first-generation DES (log-rank for cumulative ST at 1 year p<0.001). First-generation DES was a risk factor for ST (HR 5.75 [1.16-28.47], p=0.03) but not for MACCE (HR 0.89 [0.6-1.32], p=0.57).. In a real-life setting of diabetic patients undergoing PCI, second-generation DES had lower risk of ST and similar MACCE rate compared to first-generation DES. Topics: Aged; Angiography; Coronary Stenosis; Diabetes Mellitus; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Myocardial Revascularization; Paclitaxel; Percutaneous Coronary Intervention; Poland; Proportional Hazards Models; Registries; Retrospective Studies; Sirolimus; Stents; Thrombosis; Treatment Outcome | 2015 |
Comparison of abluminal biodegradable polymer biolimus-eluting stents and durable polymer everolimus-eluting stents in the treatment of coronary bifurcations.
To compare biodegradable polymer biolimus-eluting (BES) with abluminal drug elution and durable polymer everolimus-eluting (EES) stents in the treatment of bifurcation lesions.. The persistence of a polymer in drug-eluting stents (DES) following drug elution has been viewed as a possible culprit for restenosis. DES with biodegradable polymer may thus be associated with improved clinical outcomes, especially in high-risk lesions such as those at bifurcation sites.. We performed a retrospective study of consecutive de novo bifurcation lesions treated with EES between October 2006 and October 2011 and BES between February 2008 and March 2012. Study endpoints included major adverse cardiac events (MACE) defined as all-cause death, myocardial infarction (MI), including peri-procedural MI, and target vessel revascularization (TVR) as well as target lesion revascularization (TLR) separately.. We analyzed 236 bifurcation lesions treated with either BES (79 lesions in 69 patients) or EES (157 lesions in 154 patients). Patient and procedural characteristics were broadly similar between the two groups. Estimated MACE and TVR rates at 2-year follow-up were similar between the BES and EES groups (MACE = 13.6 ± 4.6% vs. 14.6 ± 3.2% (P = 0.871); TVR = 6.9 ± 3.5% vs. 8.0 ± 2.7% (P = 0.889). No significant differences were noted between the two groups following propensity-score matched analysis. There was no probable or definite stent thrombosis.. BES use in the treatment of bifurcation lesions appears to be associated with good clinical outcomes, comparable to those seen with EES, at long-term follow-up. These results are hypothesis-generating and need to be validated with larger studies. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Retrospective Studies; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2014 |
One-year outcome of biolimus eluting stent with biodegradable polymer in all comers: the Italian Nobori Stent Prospective Registry.
INSPIRE-1 (Italian Nobori Stent ProspectIve REgistry-1) was designed and conducted to assess clinical performance of Nobori biolimus A9-eluting stent (BES) implantation in an unrestricted "real-world" cohort of patients.. Unrestricted consecutive high-risk patients treated with BES with biodegradable polymer (Nobori, Terumo, Tokyo, Japan) between February 2008 and July 2012 were prospectively enrolled in an independent multicenter registry and divided in two groups: complex and non complex lesions.. 1066 patients (1589 lesions) treated with Nobori BES were analyzed. The majority of patients (57%) were treated for at least one complex lesion and presented a high-risk clinical profile (previous CABG 17.6%, diabetes mellitus 33.1%, chronic kidney disease 14.3%). Angiographic success rate was achieved in 96.2% cases. At 1 year, the primary endpoint, (composite of cardiac death, myocardial infarction, and clinically driven target vessel revascularization), occurred in 39 (4.0%) patients, and was higher in the complex lesions (5.2% vs. 2.5%, P = 0.032). Target lesion failure (TLF, secondary endpoint) occurred in 45 (4.6%) patients, and was more frequent in the complex lesions group (6.2% vs. 2.7%, P = 0.011), mainly due to a higher incidence of any target lesion revascularization (4.8% vs. 2.7%; P = 0.095). Definite and probable stent thrombosis (ST) rate was 0.6% and 0.5% respectively, with no difference between groups.. In unrestricted daily practice, BESs were implanted predominantly in high risk patients with complex lesions. Despite this, the Nobori BES was associated with a relatively low rate of primary endpoint and TLF, with a higher risk in patients with complex lesions. Topics: Absorbable Implants; Aged; Cohort Studies; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Italy; Male; Middle Aged; Myocardial Infarction; Polymers; Prospective Studies; Registries; Sirolimus; Time Factors; Treatment Outcome | 2014 |
Long-term comparison of everolimus-eluting and biolimus-eluting stents.
Second-generation everolimus-eluting stents (EES) are safer and more efficient than first-generation paclitaxel-eluting stents (PES). Third-generation biolimus-eluting stents (BES) have been found to be non-inferior to PES. To date, there is no available comparative study between EES and BES. We aimed to investigate the safety and efficacy of BES with biodegradable polymer compared to EES with durable polymer at a follow-up of two years in an unselected population of consecutively enrolled patients.. A group of 814 consecutive patients undergoing percutaneous coronary intervention (PCI) was enrolled between 2007 and 2010, of which 527 were treated with EES and 287 with BES implantation. Clinical outcome was compared in 200 pairs using propensity score matching. The primary endpoint was a composite of death, myocardial infarction (MI) and target vessel revascularisation (TVR) at two-year follow-up. Median follow-up was 22 months. The primary outcome occurred in 11.5% of EES and 10.5% of BES patients (HR 1.11, 95% CI: 0.61-2.00, p=0.74). At two years, there was no significant difference with regard to death (HR 0.49, 95% CI: 0.18-1.34, p=0.17), cardiac death (HR 0.14, 95% CI: 0.02-1.14, p=0.66) or MI (HR 6.10, 95% CI: 0.73-50.9, p=0.10). Stent thrombosis (ST) incidence was evenly distributed between EES (n=2) and BES (n=2) (p-value=1.0).. This first clinical study failed to demonstrate any significant difference regarding safety or efficacy between these two types and generations of drug-eluting stents (DES). Topics: Aged; Cardiovascular Agents; Chi-Square Distribution; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Multivariate Analysis; Myocardial Infarction; Percutaneous Coronary Intervention; Propensity Score; Proportional Hazards Models; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2013 |
New-generation drug-eluting stent experience in the percutaneous treatment of unprotected left main coronary artery disease: the NEST registry.
To explore the 2-year clinical outcomes in patients with unprotected left main coronary artery (ULMCA) disease treated with overall new drug-eluting stent (DES) options.. Recent available data have shown the feasibility and the safety of new DESs, mainly evaluating the everolimus-eluting stents in the setting of ULMCA disease.. Patients with ULMCA disease undergoing percutaneous coronary intervention (PCI) with everolimus-, zotarolimus-, and biolimus A9-eluting stents were prospectively evaluated. The study objective was the composite of major adverse cardiac events (MACEs), consisting of all-cause mortality, myocardial infarction (MI), and target vessel revascularization (TVR) at 2-year clinical follow-up.. A total of 154 patients were analyzed. The mean EuroSCORE and SYNTAX scores were 4.7 ± 2.6 and 27.5 ± 8.3, respectively. Distal location was present in 126 patients (81.8%) and 96 lesions (76.3%) were true Medina bifurcations. The 2-stent technique was used in 73 cases (57.9%). Everolimus-, zotarolimus-, and biolimus A9-eluting stents were implanted in 68 patients (44.2%), 46 patients (29.9%), and 40 patients (25.9%), respectively. At a median clinical follow-up of 551.5 days (interquartile range, 360.8-1045.5 days), MACEs occurred in 29 patients (18.8%). Ten patients (6.5%) died, and 2 deaths (1.3%) were adjudicated as cardiac. No patient had myocardial infarction or definite stent thrombosis (ST). One probable and 1 possible ST were adjudicated. TVR was required in 19 patients (12.3%) and target lesion revascularization was required in only 7 patients (4.5%).. In our experience, despite the presence of complex distal left main lesions, new DESs in ULMCA disease appear to be promising in terms of safety and efficacy at 2-year clinical follow-up. Topics: Aged; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Follow-Up Studies; Humans; Incidence; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Registries; Retrospective Studies; Sirolimus; Thrombosis; Treatment Outcome | 2013 |
Experience with BioMatrix BES and other DES in all-comers setting: a retrospective overview.
New generation DES are effectively used in all spectrum of coronary artery diseases (CAD) and are replacing earlier DES and BMS. Biolimus A9™-eluting stent is a new generation DES containing the anti-proliferative drug biolimus A9™ incorporating a biodegradable abluminal coating that leaves a polymer-free stent after drug release enhancing strut coverage while preventing neointimal hyperplasia. A retrospective data analysis was done in patients treated with DES, with a major share of Biolimus A9™ (BA9™) drug-eluting stents (DES) at Bombay Hospital, Mumbai. A total of 158 patients with 219 lesions were treated with DES, comprising Biolimus A9-eluting stent and others and the major adverse cardiac events (MACE) rate and stent thrombosis (ST) at 1, 6, 12 months and 24 months were analyzed. Mace rate was 3.16% for average follow-up of 19 months. There were 3 cases of ST (2 of acute and 1 of subacute onset) and one non-cardiac death reported during this time. This retrospective data demonstrates good one- and two-year clinical safety and efficacy of DES, especially of BioMatrix stents in real world setting. Topics: Absorbable Implants; Adult; Age Factors; Aged; Aged, 80 and over; Angioplasty, Balloon, Coronary; Cause of Death; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; India; Male; Middle Aged; Myocardial Infarction; Polymers; Prosthesis Design; Prosthesis Failure; Retrospective Studies; Risk Assessment; Severity of Illness Index; Sex Factors; Sirolimus; Survival Rate; Treatment Outcome; Young Adult | 2013 |
Critical in-stent restenosis following fracture of biolimus-eluting stent: a report of 2 cases.
The development of drug-eluting stents (DES) has dramatically reduced the incidence of in-stent restenosis. Stent fracture (SF) of DESs, however, has recently emerged as a rare but serious complication, which may lead to acute coronary syndrome or sudden cardiac death. DES fracture results from metal fatigue and vessel hemodynamic stress on the stent strut, due to markedly reduced neointimal formation. Although actual incidence of SF is not known, previous reports have demonstrated that SF rates are specific to each DES type. In this report, 2 cases of fracture of a Nobori stent are described, with insights into the mechanisms of SF and strategies for its successful management. Topics: Aged, 80 and over; Angina Pectoris; Angioplasty, Balloon, Coronary; Coronary Restenosis; Drug-Eluting Stents; Humans; Immunosuppressive Agents; Male; Middle Aged; Myocardial Infarction; Prosthesis Failure; Sirolimus | 2013 |
Clinical performance of a drug-eluting stent with a biodegradable polymer in an unselected patient population: the NOBORI 2 study.
Previous studies for approved indications (on-label) have shown the good safety and efficacy profiles of the Nobori DES. We conducted a prospective, multicentre study to validate the clinical performance of this stent in a real-world setting.. A total of 3,067 consecutive patients undergoing a percutaneous coronary intervention with the Nobori DES were enrolled in the NOBORI 2 registry. At one and two years, 97% and 95% of patients, respectively, were available for follow-up. The rates of target lesion failure (TLF), cardiac death, myocardial infarction and target lesion revascularisations were: 3.9%, 1.2%, 1.9% and 2.2% at one year and 5.1%, 1.6%, 2.4% and 3.0% at two years. Overall, 2,242 patients (73%) were treated for at least one off-label indication. When comparing off-label and on-label groups, the results were: TLF 4.5% vs. 2.2%, p=0.003 at one year and 5.9% vs. 2.8%, p=0.001 at two years. The rate of stent thrombosis was 0.68%, and 0.80% at one and two years, respectively with no difference between the off-label and on-label groups (0.76% vs. 0.48%, p=0.6 and 0.89% vs. 0.61%, p=0.5).. The promising results previously observed in lower risk patients can be replicated in daily practice. As expected, in off-label indications, rates of adverse events were higher. Nevertheless, our results suggest the good and sustained performance of this stent system in high-risk patients with significant comorbidities and/or complex lesions. Topics: Absorbable Implants; Aged; Analysis of Variance; Angioplasty, Balloon, Coronary; Asia; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Europe; Female; Guideline Adherence; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Polymers; Practice Guidelines as Topic; Product Labeling; Prospective Studies; Prosthesis Design; Registries; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2012 |
New-generation drug-eluting stents for patients with myocardial infarction.
Topics: Absorbable Implants; Drug-Eluting Stents; Female; Humans; Male; Myocardial Infarction; Myocardial Reperfusion; Sirolimus | 2012 |
Biolimus-eluting biodegradable polymer-coated stent versus bare metal stent in acute ST-elevation and non-ST elevation myocardial infarction: Justification for biodegradable polymer-coated stent in acute coronary syndrome (JANICE) registry.
We evaluated the efficacy and safety of a biolimus- eluting biodegradable polymer-coated stent (BES) in patients with ST-segment elevation and non ST-segment elevation acute myocardial infarction (AMI).. This was an observational study involving a single centre patient registry. We compared the rates of cardiac death, myocardial infarction, target vessel revascularization (TVR) and composite end point of cardiac death and myocardial infarction at 24 months in 106 patients who received BES versus 94 patients who received an otherwise similar bare metal stent (BMS) during percutaneous coronary intervention for AMI. There was no significant difference in the rate of cardiac death (0.9% versus 7.4%; P = 0.09), myocardial infarction (4.7% versus 3.2%; P = 0.69), stent thrombosis (0.9% versus 3.2%; P = 0.30) or cardiac death and myocardial infarction (5.7% versus 10.6%; P = 0.30) between the two groups. The rate of TVR was significantly higher in the BMS group (1.9% versus 8.5%; P = 0.04), with patients receiving BMS being four times more likely to require TVR.. The use of BES in selected patients with AMI appears to be safe and is associated with significantly reduced rate of TVR, when compared with an otherwise similar BMS. Topics: Absorbable Implants; Acute Coronary Syndrome; Aged; Angioplasty, Balloon, Coronary; Anti-Bacterial Agents; Death; Drug-Eluting Stents; Female; Humans; Male; Metals; Middle Aged; Myocardial Infarction; Observation; Polymers; Registries; Retrospective Studies; Safety; Sirolimus; Stents; Treatment Outcome | 2011 |
Results of percutaneous coronary intervention of the unprotected left main coronary artery in 143 patients and comparison of 30-day mortality to results of coronary artery bypass grafting.
Percutaneous coronary intervention (PCI) of the unprotected left main coronary artery (LMCA) is controversial. In 143 patients who underwent PCI of the unprotected LMCA, 30-day mortality was compared with predicted cumulative risk-adjusted perioperative surgical mortality based on logistic European System for Cardiac Operative Risk Evaluation. One-year clinical follow-up was completed in all patients. The overall major adverse cardiac event rate at 1 year was 34.3%, reflecting the high-risk profile of the patient population. Twelve patients (8%) experienced an acute myocardial infarction and 16 (11%) underwent target lesion revascularization. In 31 patients (22%) who died during the first year, median logistic European System for Cardiac Operative Risk Evaluation was 30%. Calculated RRs showed significantly lower 30-day mortality using PCI compared with predicted surgical mortality (RR 0.54, 95% confidence interval 0.31 to 0.86). Angiographic follow-up in 90 of the 118 patients alive at 6 months showed binary restenosis of 6% in patients treated with drug-eluting stents versus 29% in patients receiving bare-metal stents (p < or =0.01). In conclusion, PCI for unprotected LMCA disease was associated with acceptable short- and medium-term outcomes in patients at low to intermediate risk of bypass surgery. Mortality remains high in very high-risk patients unsuitable for surgery. However, in selected indications, PCI of the LMCA can offer an alternative to surgery, especially when using drug-eluting stents. Topics: Acute Coronary Syndrome; Aged; Aged, 80 and over; Angioplasty, Balloon, Coronary; Coronary Artery Bypass; Coronary Artery Disease; Coronary Restenosis; Female; Humans; Male; Myocardial Infarction; Outcome Assessment, Health Care; Retreatment; Risk Adjustment; Sirolimus; Stents | 2008 |