umirolimus has been researched along with Coronary-Disease* in 4 studies
1 review(s) available for umirolimus and Coronary-Disease
Article | Year |
---|---|
[Biolimus eluting stent].
Topics: Coronary Disease; Drug-Eluting Stents; Humans; Sirolimus | 2011 |
3 trial(s) available for umirolimus and Coronary-Disease
Article | Year |
---|---|
2-Year Outcomes of High Bleeding Risk Patients After Polymer-Free Drug-Coated Stents.
A 1-year follow-up, polymer-free metallic stent coated with biolimus-A9 followed by 1-month dual antiplatelet therapy is safer and more effective than a bare-metal stent (BMS) for patients with high risk of bleeding.. This study analyzed 2-year outcomes to determine whether these benefits are maintained.. In a prospective, multicenter, double-blind trial, we randomized 2,466 high bleeding risk patients to receive a drug-coated stent (DCS) or a BMS followed by 1-month dual antiplatelet therapy. The primary safety endpoint was a composite of cardiac death, myocardial infarction, or stent thrombosis. The primary efficacy endpoint was clinically driven target lesion revascularization.. At 2 years, the primary safety endpoint had occurred in 147 DCS and 180 BMS patients (15.3%) (hazard ratio: 0.80; 95% confidence interval: 0.64 to 0.99; p = 0.039). Clinically driven target lesion revascularization occurred for 77 DCS and 136 BMS patients (12.0%) (hazard ratio: 0.54; 95% confidence interval: 0.41 to 0.72; p < 0.0001). Major bleeding occurred in 8.9% of DCS and 9.2% of BMS patients (p = 0.95), and a coronary thrombotic event (myocardial infarction and/or stent thrombosis) occurred in 8.2% of DCS and 10.6% of BMS patients (p = 0.045). One-year mortality was 27.1% for a major bleed and 26.3% for a thrombotic event. At 2 years, multivariate correlates of major bleeding were age >75 years, anemia, raised plasma creatinine, and planned long-term anticoagulation. Correlates of the primary safety endpoint were age, anemia, congestive heart failure, multivessel disease, number of stents implanted, and use of a BMS rather than a DCS.. Safety and efficacy benefits of DCS over BMS were maintained for 2 years in high bleeding risk patients. Rates of major bleeding and coronary thrombotic events were no different and were associated with a substantial and comparable mortality risk. (A Prospective Randomized Comparison of the BioFreedom Biolimus A9 Drug Coated Stent Versus the Gazelle Bare Metal Stent in Patients With High Risk of Bleeding [LEADERS FREE]; NCT01623180). Topics: Aged; Aged, 80 and over; Angioplasty, Balloon, Coronary; Coronary Disease; Coronary Thrombosis; Death; Double-Blind Method; Drug Therapy, Combination; Drug-Eluting Stents; Female; Hemorrhage; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Platelet Aggregation Inhibitors; Proportional Hazards Models; Prospective Studies; Risk; Sirolimus; Statistics as Topic; Stents; Survival Rate | 2017 |
Study design and rationale of "a multicenter, open-labeled, randomized controlled trial comparing three 2nd-generation drug-eluting stents in real-world practice" (CHOICE trial).
The second-generation drug-eluting stents (DES) have shown superiority in many studies relating to safety and efficacy when compared with the first-generation DES. However, it is unclear whether there are differences in efficacy and safety among the second-generation DES after long-term follow-up.. This multicenter, prospective, randomized, open-labeled trial will directly compare the efficacy and safety among the patients treated with either everolimus-eluting stent (EES), zotarolimus-eluting stent with biolinx polymer (ZES-R), or biolimus-eluting stent (BES) with minimal exclusion criteria. The primary end point is a patient-oriented composite consisted of cardiac death, myocardial infarction not clearly attributable to a nontarget vessel and clinically indicated target lesion revascularization at 24-month clinical follow-up post-index procedure. With the hypothesis that "BES is non-inferior to EES" or "BES is non-inferior to ZES-R" in primary end point, approximately 2,600 patients will be assigned to one of the types of stents using a web-based randomization system.. The CHOICE trial will directly compare the efficacy and safety of EES, ZES-R, and BES in everyday clinical practice for long-term follow-up. Topics: Adult; Algorithms; Coronary Disease; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Myocardial Infarction; Prosthesis Design; Sirolimus | 2013 |
Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): a randomised non-inferiority trial.
A novel stent platform eluting biolimus, a sirolimus analogue, from a biodegradable polymer showed promising results in preliminary studies. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with a sirolimus-eluting stent (with durable polymer).. We undertook a multicentre, assessor-blind, non-inferiority study in ten European centres. 1707 patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes were centrally randomised by a computer-generated allocation sequence to treatment with either biolimus-eluting (n=857) or sirolimus-eluting (n=850) stents. The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation within 9 months. Analysis was by intention to treat. 427 patients were randomly allocated to angiographic follow-up, with in-stent percentage diameter stenosis as principal outcome measure at 9 months. The trial is registered with ClinicalTrials.gov, number NCT00389220.. We analysed all randomised patients. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents for the primary endpoint at 9 months (79 [9%] patients vs 89 [11%], rate ratio 0.88 [95% CI 0.64-1.19], p for non-inferiority=0.003, p for superiority=0.39). Frequency of cardiac death (14 [1.6%] vs 21 [2.5%], p for superiority=0.22), myocardial infarction (49 [5.7%] vs 39 [4.6%], p=0.30), and clinically-indicated target vessel revascularisation (38 [4.4%] vs 47 [5.5%], p=0.29) were similar for both stent types. 168 (79%) patients in the biolimus-eluting group and 167 (78%) in the sirolimus-eluting group had data for angiographic follow-up available. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents in in-stent percentage diameter stenosis (20.9%vs 23.3%, difference -2.2% [95% CI -6.0 to 1.6], p for non-inferiority=0.001, p for superiority=0.26).. Our results suggest that a stent eluting biolimus from a biodegradable polymer represents a safe and effective alternative to a stent eluting sirolimus from a durable polymer in patients with chronic stable coronary artery disease or acute coronary syndromes.. Biosensors Europe SA, Switzerland. Topics: Absorbable Implants; Aged; Biocompatible Materials; Chronic Disease; Coronary Disease; Drug-Eluting Stents; Female; Humans; Male; Materials Testing; Metals; Middle Aged; Polymers; Sirolimus; Thrombosis; Treatment Outcome | 2008 |