umirolimus has been researched along with Coronary-Artery-Disease* in 109 studies
6 review(s) available for umirolimus and Coronary-Artery-Disease
Article | Year |
---|---|
True double bifurcation lesions: new application of the self-expandable Axxess stent and review of literature with dedicated bifurcation devices.
Complex coronary artery bifurcation lesions occurred in hard clinical scenarios, such as acute coronary syndromes, may represent a challenge for interventional cardiologists, with not-defined general consensus on treatment. Even if provisional stenting is the most common option used to restore rapidly the coronary branches flow, improvements in industrial technologies and design of new dedicated bifurcation devices might open new modalities of treatment in these complex cases. The Axxess stent (Biosensors Europe SA, Morges, Switzerland) is a self-expanding biolimus-eluting conical V-shape stent, specifically designed to treat "easily" coronary artery bifurcation lesions, with reported favorable long-term clinical results in stable patients compared to a provisional technique. We report for the first time the feasibility to use this device in a case of "true double coronary bifurcation lesion" occurred in the context of acute coronary syndrome. Moreover, we reviewed studies with bifurcation dedicated devices and available cases of "true double bifurcation lesions", underlying advantages/disadvantages of using one device over the others during acute coronary syndrome. Topics: Acute Coronary Syndrome; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Humans; Male; Prosthesis Design; Sirolimus; Treatment Outcome | 2019 |
Impact of side branch stenting on five-year long-term clinical outcome with the bifurcation-dedicated Axxess Biolimus A9-eluting stent system.
Our aim was to evaluate the five-year clinical impact of side branch (SB) stenting with a drug-eluting stent (DES) following Axxess stent implantation in coronary bifurcation lesions.. Four hundred patients treated with Axxess were pooled from the AXXESS Plus and DIVERGE five-year follow-up studies. We compared unadjusted and propensity-adjusted major adverse clinical events (MACE) between Axxess with no SB stenting ("Axxess provisional") versus Axxess with SB stenting ("Axxess additional"). "Axxess additional" had no impact on the MACE rate, with unadjusted and adjusted HR 1.59 (95% CI: 0.95-2.64) and 1.37 (95% CI: 0.88-2.13), respectively. No differences were seen in the individual components of death, myocardial infarction and ischaemia-driven target lesion revascularisation, respectively, both in unadjusted (HR 0.92 [95% CI: 0.38-2.19]; HR 1.73 [95% CI: 0.78-3.82]; HR 1.65 [95% CI: 0.84-3.26]) and adjusted analysis (HR 0.92 [95% CI: 0.41-2.09]; HR 1.13 [95% CI: 0.59-2.17]; HR 1.31 [95% CI: 0.74-2.31]). No differences in definite stent thrombosis were seen with unadjusted HR 2.1 (95% CI: 0.45-9.88) and adjusted HR 1.0 (95% CI: 0.32-3.1).. Stenting the SB following Axxess implantation does not impact on long-term clinical outcomes compared to MV stenting only. The Axxess stent system offers a safe and tailored alternative for the treatment of coronary bifurcation lesions. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Kaplan-Meier Estimate; Logistic Models; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Propensity Score; Proportional Hazards Models; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2015 |
Clinical outcomes of patients treated with Nobori biolimus-eluting stent: Meta-analysis of randomized trials.
The Nobori is a new-generation, biodegradable-polymer coated, biolimus-eluting stent (BES) that has recently been investigated in several randomized trials with inconsistent results. The aim of this study was to assess the efficacy and safety of Nobori BES versus other drug-eluting stents (DES) in patients treated with percutaneous coronary intervention (PCI).. We undertook a meta-analysis of randomized trials investigating Nobori BES versus other DES. Primary efficacy and safety outcomes were target lesion revascularization (TLR) and definite/probable stent thrombosis (ST), respectively. Secondary outcomes were the composite of cardiac death/myocardial infarction (MI)/target vessel revascularization (TVR), MI and death.. A total of 9114 PCI-patients randomly received Nobori BES (n=5080) or other DES (n=4034). This latter group comprised patients receiving everolimus- (n=2533), sirolimus- (n=1376) or paclitaxel-eluting stents (n=125). Median follow-up was 11 months [interquartile range 9-12]. The Nobori BES versus other DES showed comparable risk of TLR (odds ratio [95% confidence interval]=0.91 [0.57-1.46], p=0.71). There was significant heterogeneity across trials due to significant lower TLR risk with Nobori BES versus paclitaxel-eluting stent (0.32 [0.10-0.98], p=0.046; p for interaction=0.009). Nobori BES versus other DES showed comparable risk of definite/probable ST (1.40 [0.66-2.97], p=0.39), cardiac death/MI/TVR (1.05 [0.88-1.25], p=0.59), MI (1.13 [0.87-1.48], p=0.37) and death (1.09 [0.81-1.48], p=0.56).. Nobori BES has comparable efficacy with other limus-eluting stents at 1-year follow-up. There is no difference in terms of safety profile between these stent platforms. Topics: Coronary Artery Disease; Drug-Eluting Stents; Follow-Up Studies; Humans; Percutaneous Coronary Intervention; Randomized Controlled Trials as Topic; Sirolimus; Treatment Outcome | 2014 |
Long-term outcomes of biodegradable polymer versus durable polymer drug-eluting stents in patients with diabetes a pooled analysis of individual patient data from 3 randomized trials.
There is ongoing debate on the optimal drug-eluting stent (DES) in diabetic patients with coronary artery disease. Biodegradable polymer drug-eluting stents (BP-DES) may potentially improve clinical outcomes in these high-risk patients. We sought to compare long-term outcomes in patients with diabetes treated with biodegradable polymer DES vs. durable polymer sirolimus-eluting stents (SES).. We pooled individual patient-level data from 3 randomized clinical trials (ISAR-TEST 3, ISAR-TEST 4 and LEADERS) comparing biodegradable polymer DES with durable polymer SES. Clinical outcomes out to 4 years were assessed. The primary end point was the composite of cardiac death, myocardial infarction and target-lesion revascularization. Secondary end points were target lesion revascularization and definite or probable stent thrombosis.. Of 1094 patients with diabetes included in the present analysis, 657 received biodegradable polymer DES and 437 durable polymer SES. At 4 years, the incidence of the primary end point was similar with BP-DES versus SES (hazard ratio = 0.95, 95% CI = 0.74-1.21, P = 0.67). Target lesion revascularization was also comparable between the groups (hazard ratio = 0.89, 95% CI = 0.65-1.22, P = 0.47). Definite or probable stent thrombosis was significantly reduced among patients treated with BP-DES (hazard ratio = 0.52, 95% CI = 0.28-0.96, P = 0.04), a difference driven by significantly lower stent thrombosis rates with BP-DES between 1 and 4 years (hazard ratio = 0.15, 95% CI = 0.03-0.70, P = 0.02).. In patients with diabetes, biodegradable polymer DES, compared to durable polymer SES, were associated with comparable overall clinical outcomes during follow-up to 4 years. Rates of stent thrombosis were significantly lower with BP-DES. Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Coronary Artery Disease; Diabetes Complications; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Multicenter Studies as Topic; Polymers; Randomized Controlled Trials as Topic; Risk Assessment; Sirolimus; Thrombosis; Treatment Outcome | 2013 |
Future stent drug delivery systems.
Drug-eluting stents (DES) with antiproliferative drugs attached via polymers on the stent surface have reduced in-stent restenosis and repeat revascularization compared with bare metal stent (BMS) across nearly all lesion and patient subsets. However, the small number of patients with in-stent restenosis after DES treatment still exists. Furthermore, concerns about long-term safety of DES are raised, particularly regarding the higher-than-expected late-event thrombosis. There is no doubt that the DES will continue to play a pivotal role in the treatment of coronary artery disease, yet future designs need to incorporate features that reduce thrombosis and promote endothelialization along with maintaining the efficacy. This review focuses on novel generation of DES, discussing new programs, including new antiproliferative agents, novel polymeric and non polymeric stents. Topics: Absorbable Implants; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Equipment Design; Everolimus; Evidence-Based Medicine; Humans; Immunosuppressive Agents; Polymers; Prosthesis Design; Sirolimus; Tacrolimus | 2008 |
BioMatrix Biolimus A9-eluting coronary stent: a next-generation drug-eluting stent for coronary artery disease.
Drug-eluting stent technology consisting of a bare metal stent, carrier coating, bioactive drug and delivery system, offers an almost infinite range of possible device configurations. A growing understanding of the mechanisms of restenosis allows for the design of synergistic functions within these components, thus providing a basis for new and improved products. The BioMatrix stent (Biosensors Interventional Technologies Pte Ltd., Singapore) elutes the new sirolimus derivative Biolimus A9 from a biodegradable polylactic acid polymer. Biolimus A9 possesses enhanced anti-inflammatory and antiproliferative activity with an improved pharmacokinetic profile. Permanent polymer-carrier-based platforms may be associated with inflammation, late thrombosis and restenosis. The BioMatrix, with its asymmetric and abluminal coating, releases Biolimus A9 into the vessel wall while the polylactic acid polymer is resorbed by surrounding tissues. Clinical studies have demonstrated the BioMatrix to be well tolerated and effective, and it has now become the subject of an aggressive clinical program. Topics: Animals; Coated Materials, Biocompatible; Coronary Artery Disease; Coronary Restenosis; Drug Carriers; Drug Delivery Systems; Humans; Lactic Acid; Polyesters; Polymers; Randomized Controlled Trials as Topic; Sirolimus; Stents | 2006 |
54 trial(s) available for umirolimus and Coronary-Artery-Disease
Article | Year |
---|---|
Stent strut thickness and acute vessel injury during percutaneous coronary interventions: an optical coherence tomography randomized clinical trial.
Compare the degree of acute vascular injury caused by a polymer-free, thin-strut drug-eluting stent (DES) to that caused by a bioresorbable polymer, thick-strut DES using optical coherence tomography (OCT).. Fifty patients requiring nonurgent PCI were randomized to receive either a thin or a thick-strut DES. OCT was performed before and after stent implantation. OCT-based injury score (IS) after implantation was numerically higher within thick-strut stents 0.32 vs. 0.23, but the difference was NS (P = 0.61). Edge dissections were present in 36% of the patients without differences between groups. Tissue prolapse (TP) area was larger with thin-strut stents (2.26 vs. 1.83 mm2, P = 0.04). Stent expansion and symmetry index were similar between the two platforms (85% vs. 94%, P = 0.08; and 0.82 vs. 0.80, P = 0.25). No differences were observed in total malapposition area (1.85 mm2 in thin-strut stents vs. 1.47 mm2, P = 0.48). Regarding the influence of plaque-type, IS tended to be higher (non-significant) with thick strut DES in fibrocalcific plaques. Stent malapposition area was smaller in fibrous plaques, especially with thin strut stents (P = 0.03).. There was no difference in the extent of OCT-based vessel injury associated with thin and thick-strut DES platforms. TP was larger with the thin strut DES, potentially reflecting a deeper stent embedment in the vessel wall. Topics: Aged; Biodegradable Plastics; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Intraoperative Complications; Male; Outcome Assessment, Health Care; Percutaneous Coronary Intervention; Plaque, Atherosclerotic; Sirolimus; Tomography, Optical Coherence; Vascular System Injuries | 2021 |
Polymer-based or Polymer-free Stents in Patients at High Bleeding Risk.
Polymer-free drug-coated stents provide superior clinical outcomes to bare-metal stents in patients at high bleeding risk who undergo percutaneous coronary intervention (PCI) and are treated with 1 month of dual antiplatelet therapy. Data on the use of polymer-based drug-eluting stents, as compared with polymer-free drug-coated stents, in such patients are limited.. In an international, randomized, single-blind trial, we compared polymer-based zotarolimus-eluting stents with polymer-free umirolimus-coated stents in patients at high bleeding risk. After PCI, patients were treated with 1 month of dual antiplatelet therapy, followed by single antiplatelet therapy. The primary outcome was a safety composite of death from cardiac causes, myocardial infarction, or stent thrombosis at 1 year. The principal secondary outcome was target-lesion failure, an effectiveness composite of death from cardiac causes, target-vessel myocardial infarction, or clinically indicated target-lesion revascularization. Both outcomes were powered for noninferiority.. A total of 1996 patients at high bleeding risk were randomly assigned in a 1:1 ratio to receive zotarolimus-eluting stents (1003 patients) or polymer-free drug-coated stents (993 patients). At 1 year, the primary outcome was observed in 169 of 988 patients (17.1%) in the zotarolimus-eluting stent group and in 164 of 969 (16.9%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% confidence interval [CI], 3.5; noninferiority margin, 4.1; P = 0.01 for noninferiority). The principal secondary outcome was observed in 174 patients (17.6%) in the zotarolimus-eluting stent group and in 169 (17.4%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% CI, 3.5; noninferiority margin, 4.4; P = 0.007 for noninferiority).. Among patients at high bleeding risk who received 1 month of dual antiplatelet therapy after PCI, use of polymer-based zotarolimus-eluting stents was noninferior to use of polymer-free drug-coated stents with regard to safety and effectiveness composite outcomes. (Funded by Medtronic; ONYX ONE ClinicalTrials.gov number, NCT03344653.). Topics: Coronary Artery Disease; Coronary Thrombosis; Drug Therapy, Combination; Drug-Eluting Stents; Heart Diseases; Hemorrhage; Humans; Immunosuppressive Agents; Kaplan-Meier Estimate; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Polymers; Prosthesis Design; Single-Blind Method; Sirolimus | 2020 |
Clinical outcomes three-year after revascularization with biodegradable polymer stents: ultrathin-strut sirolimus-eluting stent versus biolimus-eluting stent: from the Scandinavian organization for randomized trials with clinical outcome VII trial.
Drug-eluting stents with biodegradable polymers have been designed to improve safety and efficacy. However, drug-eluting stents with biodegradable polymers may not be a class effect, as stent strut thickness, polymer coating, and drug resorption differ between these groups of stents. Twelve months results of Scandinavian Organization for Randomized Trials With Clinical Outcome VII showed that ultrathin-strut sirolimus-eluting Orsiro stent was noninferior to the biolimus-eluting Nobori stent. The sirolimus-eluting Orsiro stent was associated with a reduced risk of definite stent thrombosis.. The Scandinavian Organization for Randomized Trials With Clinical Outcome VII trial is a prospective multicenter randomized clinical trial comparing sirolimus-eluting Orsiro stent and biolimus-eluting Nobori stent in all-comers patients. The endpoint target lesion failure was a composite of cardiac death, myocardial infarction (not related to other than index lesion) and target lesion revascularization.. A total of 1261 patients were randomized to treatment with sirolimus-eluting Orsiro stent and 1264 patients to biolimus-eluting Nobori stent and followed for 3 years. At 3-year the target lesion failure was comparable for sirolimus-eluting Orsiro stent (9.0%) and the biolimus-eluting Nobori stent (9.1%), (rate ratio, 0.99; 95% confidence interval, 0.77-1.29). Cardiac death (sirolimus-eluting Orsiro stent 3.0% vs. biolimus-eluting Nobori stent 2.6% [rate ratio, 1.16; 95% confidence interval, 0.73-1.86]), target lesion revascularization (sirolimus-eluting Orsiro stent 5.2% vs. biolimus-eluting Nobori stent 5.9% [rate ratio, 0.90; 95% confidence interval, 0.64-1.25]), myocardial infarction (sirolimus-eluting Orsiro stent 4.7% vs. biolimus-eluting Nobori stent 4.5% [rate ratio, 1.04; 95% confidence interval, 0.72-1.50]), and definite stent thrombosis (sirolimus-eluting Orsiro stent 1.0% vs. biolimus-eluting Nobori stent 1.7% [rate ratio, 0.59; 95% confidence interval, 0.30-1.18]) did not differ significantly between the two groups.. At 3-year follow-up, target lesion failure did not differ among ultrathin-strut sirolimus-eluting Orsiro stent and biolimus-eluting Nobori stent with biodegradable polymers. Topics: Absorbable Implants; Aged; Coronary Artery Disease; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Myocardial Revascularization; Polymers; Prospective Studies; Prosthesis Design; Single-Blind Method; Sirolimus; Time Factors; Treatment Outcome | 2020 |
Randomized Comparison of the Polymer-Free Biolimus-Coated BioFreedom Stent With the Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Orsiro Stent in an All-Comers Population Treated With Percutaneous Coronary Intervention: The SORT OUT IX Trial.
In patients with increased bleeding risk, the biolimus A9-coated BioFreedom stent, a stainless steel drug-coated stent free from polymer, has shown superiority compared with a bare-metal stent. The aim of this study was to investigate whether the BioFreedom stent is noninferior to a modern ultrathin strut biodegradable polymer cobalt-chromium sirolimus-eluting Orsiro stent in an all-comers patient population treated with percutaneous coronary intervention.. The SORT OUT IX trial (Scandinavian Organization for Randomized Trials With Clinical Outcome IX), was a large-scale, registry-based, randomized, multicenter, single-blind, 2-arm, noninferiority trial. The primary end point, major adverse cardiovascular events, was defined as the composite of cardiac death, myocardial infarction not related to any segment other than the target lesion, or target lesion revascularization within 1 year, analyzed by intention-to-treat. The trial was powered to assess noninferiority for major adverse cardiovascular events of the BioFreedom stent compared with the Orsiro stent with a predetermined noninferiority margin of 0.021.. Between December 14, 2015 and April 21, 2017, 3151 patients were assigned to treatment with the BioFreedom stent (1572 patients, 1966 lesions) or to the Orsiro stent (1579 patients, 1985 lesions). Five patients were lost to follow-up because of emigration (99.9% follow-up rate). Mean age was 66.3±10.9, diabetes mellitus was seen in 19.3% of patients, and 53% of the patients had acute coronary syndromes. At 1 year, intention-to-treat analysis showed that 79 (5.0%) patients, who were assigned the BioFreedom stent, and 59 (3.7%), who were assigned the Orsiro stent, met the primary end point (absolute risk difference 1.29% [upper limit of one-sided 95% CI 2.50%];. The biolimus A9-coated BioFreedom polymer-free stent did not meet criteria for noninferiority for major adverse cardiovascular events at 12 months when compared with the ultrathin strut biodegradable polymer sirolimus-eluting Orsiro stent in an all-comers population Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02623140. Topics: Absorbable Implants; Aged; Anti-Inflammatory Agents; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Incidence; Male; Middle Aged; Percutaneous Coronary Intervention; Polymers; Sirolimus; Treatment Outcome | 2020 |
Comparison Between Optical Frequency Domain Imaging and Intravascular Ultrasound for Percutaneous Coronary Intervention Guidance in Biolimus A9-Eluting Stent Implantation: A Randomized MISTIC-1 Non-Inferiority Trial.
Given the characteristic differences between intravascular ultrasound (IVUS) and optical frequency domain imaging (OFDI), their approach to therapeutic guidance during percutaneous coronary interventions (PCIs) and arterial healing response after stenting may also vary.. MISTIC-1 (The Multimodality Imaging Study in Cardiology cohort 1) is a multicenter, randomized-controlled, noninferiority trial that compared imaging end points between OFDI- and IVUS-guided PCI. Patients with stable coronary artery disease were randomly assigned to either OFDI- or IVUS-guided PCI using a Biolimus A9-eluting stent according to a prespecified protocol for imaging guidance. Stent sizing was based on external elastic lamina in IVUS-guided PCI while lumen up-size in OFDI-guided PCI. Postprocedural OFDI was investigated regardless of randomization, while operators in IVUS-guided PCI arm were blinded to the images. The primary end point was in-segment minimum lumen area assessed using OFDI at 8 months, while the secondary end point was a composite of cardiovascular mortality, target-vessel myocardial infarction, or target-lesion revascularization (device-oriented composite end point). Patients were followed up to 3 years after the index procedure.. OFDI-guided PCI was not inferior to IVUS-guided PCI in terms of in-segment minimum lumen area at 8 months. Although a small sample size was acknowledged, OFDI could be an alternative to IVUS when considering intracoronary imaging-guided PCI in selected populations with coronary artery diseases. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03292081. Topics: Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Japan; Male; Neointima; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2020 |
Impact of diabetes on clinical outcomes after revascularization with sirolimus-eluting and biolimus-eluting stents with biodegradable polymer from the SORT OUT VII trial.
In this substudy of the SORT OUT VII trial, the clinical outcomes among patient with diabetes mellitus treated with Orsiro sirolimus-eluting stent (O-SES; Biotronik, Bülach, Switzerland) or Nobori biolimus-eluting stent (N-BES; Terumo, Tokyo, Japan) were compared.. Diabetes is associated with increased risk of target lesion failure (TLF) after percutaneous coronary intervention.. In total, 2525 patients were randomized to stent implantation with O-SES (n = 1261, diabetes: n = 236) or N-BES (n = 1264, diabetes: n = 235). The primary endpoint, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 2 years.. At 2 year, TLF did not differ between O-SES vs N-BES in diabetic (9.3% vs 9.4%; RR 0.98, 95% CI 0.54-1.78) patients. The individual components of the primary endpoint did not differ among stent type. In diabetics, cardiac death occurred in 3% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.77, 95% CI 0.29-2.08), MI occurred in 3.0% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.76, 95% CI 0.28-2.06) and TLR occurred in 5,5% of O-SES-treated and in 6.0% of N-BES-treated patients (RR 0.91, 95% CI 0.43-1.95).. TLF did not differ between O-SES- and N-BES-treated diabetic patients. Topics: Absorbable Implants; Acute Coronary Syndrome; Aged; Cardiovascular Agents; Coronary Artery Disease; Diabetes Mellitus; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2019 |
Randomized comparison between 2-link cell design biolimus A9-eluting stent and 3-link cell design everolimus-eluting stent in patients with de novo true coronary bifurcation lesions: the BEGIN trial.
The appropriate stent platform for treating coronary bifurcation lesions (CBLs) remains controversial. Previous bench tests have demonstrated the superiority of a 2-link cell design to 3-link cell design for creating inter-strut dilation at the side branch ostium. This randomized multicenter prospective BEGIN trial compared the biodegradable polymer-based biolimus A9-eluting stent (2-link BES) with the durable polymer-based cobalt chromium everolimus-eluting stent (3-link EES) in 226 patients with de novo CBLs. Patients with true bifurcations, defined as > 50% stenosis in the main vessel and side branch (SB) and an SB diameter > 2.25 mm, were enrolled. Guide wire re-crossing to the distal cell (near the carina) in the jailed SB and final kissing inflation were recommended. The SB angiographic endpoint was < 50% stenosis diameter. Left-main CBLs (13.5% vs. 13.0%) and 2-stent technique (30.6% vs. 22.6%) rates were similar. The primary endpoints (minimum lumen diameter at the SB ostium measured at an independent core laboratory at the 8-month follow-up) were comparable (1.64 ± 0.50 mm vs. 1.63 ± 0.51 mm, p = 0.976). There was no significant difference in composite outcomes of cardiac death, myocardial infarction, or target vascular revascularization at 12 months (7.4% vs. 8.0%, p = 0.894). Two-link BES and 3-link EES showed similar 8-month angiographic and 1-year clinical outcomes for true CBLs. Topics: Absorbable Implants; Aged; Aged, 80 and over; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Humans; Japan; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome | 2019 |
Everolimus-Eluting Versus Biolimus-Eluting Stents With Biodegradable Polymers in Unselected Patients Undergoing Percutaneous Coronary Intervention: A Randomized Noninferiority Trial With 1-Year Follow-Up (SORT OUT VIII Trial).
The aim of this study was to compare the thin-strut biodegradable-polymer everolimus-eluting platinum-chromium stent (EES) with the biodegradable-polymer biolimus-eluting stainless-steel stent (BES).. Currently available drug-eluting coronary stents have been refined to reduce the risk for coronary events following implantation.. This randomized, multicenter, all-comers, noninferiority trial was undertaken at 3 sites in western Denmark. Patients with clinical indications for percutaneous coronary intervention were eligible for inclusion. Patients were randomly assigned (1:1) to either EES or BES. The primary endpoint, target lesion failure, was a composite of safety (cardiac death and myocardial infarction not clearly attributable to a nontarget lesion) and efficacy (target lesion revascularization) at 12 months, analyzed using intention-to-treat principles. The trial was powered to assess target lesion failure noninferiority of the EES compared with the BES with a predetermined noninferiority margin of 3%.. A total of 1,385 patients were assigned to treatment with EES and 1,369 patients to treatment with BES. The analysis showed that 55 patients (4.0%) assigned to the EES and 60 (4.4%) assigned to the BES met the primary endpoint (absolute risk difference 0.4%; upper limit of 1-sided 95% confidence interval: 1.7%; p < 0.001).. At 1-year follow-up, the EES was found to be noninferior to the BES with respect to target lesion failure. (Everolimus-eluting SYNERGY Stent Versus Biolimus-Eluting Biomatrix NeoFlex Stent-SORT-OUT VIII; NCT02093845). Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Denmark; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome | 2019 |
Everolimus-Eluting Versus Biolimus-Eluting Coronary Stent Implantation in Patients With and Without Diabetes Mellitus.
Diabetes mellitus is associated with a higher risk of target lesion revascularization after percutaneous coronary intervention. We compared clinical outcomes in patients with and without diabetes mellitus, treated with everolimus-eluting stents (EES; Synergy; Boston Scientific, Marlborough, Massachusetts) or biolimus-eluting stents (BES; BioMatrix NeoFlex; Biosensors Interventional Technologies Pte Ltd., Singapore). In total, 2,764 patients were randomized to stent implantation with EES (n = 1,385, diabetes: n = 250) or the BES (n = 1,379, diabetes: n = 262), stratified by gender and diabetes. The primary end point, target lesion failure (TLF), was a composite of cardiac death, target-lesion myocardial infarction, or target lesion revascularization at 12 months. Secondary end points included individual components of TLF, all-cause death, and stent thrombosis. TLF was 2.1% lower in the EES versus the BES groups in patients with diabetes (3.6% vs 5.7%; rate ratios 0.61, 95% confidence interval [CI] 0.27 to 1.41) and similar in patients without diabetes (4.1% vs 4.0%; rate ratios 0.99, 95% CI 0.66 to 1.51). In patients with diabetes, the point estimates of the individual components of TLF also favored the EES but CIs were wide. No interaction between stent type and presence of diabetes was found. The current subgroup analysis found that a thin-strut EES as compared with a thicker strut BES had a numerically lower TLF rate in patients with diabetes, but the subgroup analysis was underpowered for definite conclusions. Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Confidence Intervals; Coronary Angiography; Coronary Artery Disease; Diabetes Mellitus; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Odds Ratio; Percutaneous Coronary Intervention; Reference Values; Risk Assessment; Severity of Illness Index; Sirolimus; Survival Rate; Treatment Outcome | 2019 |
Two-year outcome after biodegradable polymer sirolimus- and biolimus-eluting coronary stents (from the randomised SORT OUT VII trial).
Topics: Absorbable Implants; Cardiovascular Agents; Coated Materials, Biocompatible; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Humans; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2018 |
Second-Generation vs. First-Generation Drug-Eluting Stents in Patients With Calcified Coronary Lesions - Pooled Analysis From the RESET and NEXT Trials.
The comparative efficacy of second-generation (G2) vs. first-generation (G1) drug-eluting stents (DES) for calcified coronary lesions is unknown.Methods and Results:We compared the 3-year clinical outcomes of patients with G1- or G2-DES according to the presence or absence of calcified coronary lesions as assessed in an angiographic core laboratory using data from 2 large-scale prospective multicenter randomized trials, RESET and NEXT. G1-DES and G2-DES were implanted in 299 and 1,033 patients, respectively, in the Calc stratum (≥1 lesion with moderate/severe calcification), and 1,208 and 3,550 patients, respectively, in the Non-calc stratum (no/mild calcification). The patients in the Calc stratum had a significantly higher adjusted risk for the primary outcome measure (any target-lesion revascularization (TLR)) than those in the Non-calc stratum (HR: 1.38, 95% CI: 1.11-1.71, P=0.004). The cumulative 3-year incidence of any TLR was not significantly different between the G1-DES and G2-DES groups in both the Calc and Non-calc strata (12.1% vs. 9.7%, P=0.22, and 6.8% vs. 6.1%, P=0.44, respectively). After adjusting for confounders, the effect of G2DES relative to G1-DES for any TLR remained insignificant in both the Calc and Non-calc strata (HR: 0.78, 95% CI: 0.48-1.25, P=0.3, and HR: 0.84, 95% CI: 0.61-1.17, P=0.31, respectively, P interaction=0.55).. The effect of G2-DES relative to G1-DES for TLR was not significantly different regardless of the presence or absence of lesion calcification. Topics: Aged; Calcinosis; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Myocardial Revascularization; Sirolimus; Treatment Outcome | 2018 |
Safety of six-month dual antiplatelet therapy after second-generation drug-eluting stent implantation: OPTIMA-C Randomised Clinical Trial and OCT Substudy.
There are few randomised studies concerning the optimal duration of dual antiplatelet therapy (DAPT) for patients who receive a second-generation drug-eluting stent (DES). This trial aimed to investigate the safety of six-month compared with 12-month DAPT maintenance after second-generation DES implantation.. A prospective, randomised, multicentre trial was performed at 10 medical centres. The 1,368 patients included in the study received a biolimus-eluting stent (BES) or a zotarolimus-eluting stent (ZES). The primary outcome measured was the composite of major adverse cardiac events (MACE), including cardiac death, myocardial infarction (MI), or ischaemia-driven target lesion revascularisation at the 12-month follow-up. The secondary outcome was the percentage of uncovered struts at six months in 60 patients (30 ZES, 30 BES) using optical coherence tomography (OCT) assessment. Each patient was randomly assigned to six-month (n=684) or 12-month DAPT (n=684). Major adverse cardiac events at 12 months occurred in eight patients (1.2%) in the six-month DAPT group and in four patients (0.6%) in the 12-month DAPT group (risk difference 0.6%; 95% confidence interval [CI]: -0.4-1.6%; p=0.24). The upper 95% CI limit was lower than the pre-specified limit of 4% non-inferiority (p for non-inferiority <0.05). The percentage of uncovered struts was 3.16±4.30% at six months in 60 stents of 60 patients.. After second-generation DES implantation, six-month DAPT was not inferior to 12-month DAPT in terms of MACE occurrence over the 12-month follow-up period. OCT examination revealed favourable stent strut coverage at six months after stent implantation. Topics: Aged; Aspirin; Cardiovascular Agents; Clopidogrel; Coronary Angiography; Coronary Artery Disease; Drug Administration Schedule; Drug Therapy, Combination; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Republic of Korea; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2018 |
Long-term outcomes after percutaneous revascularization of complex coronary bifurcation lesions using a dedicated self-expanding biolimus-eluting stent system.
To evaluate long-term clinical outcomes after treatment of complex bifurcation lesions with the AXXESS dedicated self-expanding biolimus A9-eluting bifurcation stent.. Between 2004 and 2013, 123 patients with complex bifurcation lesions were treated in a single-center with the AXXESS stent in the proximal main vessel (MV) and additional drug-eluting stents in branches when required. Median follow-up was 5 years. Primary endpoint was the rate of major adverse cardiac events (MACE). Secondary endpoints included MACE components (cardiac death, non-periprocedural clinical myocardial infarction [MI], target lesion revascularization [TLR] and definite/probable stent thrombosis [ST]) as well as all-cause death, target vessel revascularization (TVR) and non-TVR.. During follow-up, 11 (8.9%) patients experienced a MACE, of whom 2 (1.6%) suffered cardiac death, 2 (1.6%) had a non-periprocedural clinical MI requiring TLR, and 7 (5.7%) underwent elective TLR. No definite/probable ST was observed. All-cause death occurred in 9 (7.3%) patients, TVR in 11 (8.9%) and non-TVR in 11 (8.9%). Patients treated for left main (LM) bifurcation lesions were more likely to experience MACE than non-LM bifurcation lesions (25% vs. 6.5%, p = 0.04).. Percutaneous revascularization of complex bifurcation lesions with the AXXESS stent is safe and provides excellent long-term results, especially in non-LM lesions. Topics: Aged; Coronary Angiography; Coronary Artery Disease; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Percutaneous Coronary Intervention; Prosthesis Design; Retrospective Studies; Self Expandable Metallic Stents; Sirolimus; Time Factors; Treatment Outcome | 2018 |
Early Strut Coverage in Patients Receiving Drug-Eluting Stents and its Implications for Dual Antiplatelet Therapy: A Randomized Trial.
This study sought to measure early strut coverage in patients receiving drug-eluting stents (DESs) and to explore the feasibility of short-term dual antiplatelet therapy (DAPT) based on the degree of early strut coverage.. Data for early strut coverage in patients receiving new-generation DESs, and its implications for DAPT continuation were limited.. A randomized, multicenter trial was conducted in 894 patients treated with DESs. Patients were randomly assigned to everolimus-eluting stent (EES) (n = 444) or biolimus-eluting stent (BES) (n = 450) groups and optical coherence tomography (OCT)-guided (n = 445) or angiography-guided (n = 449) implantation groups using a 2-by-2 factorial design. Early strut coverage was measured as the percentage of uncovered struts on 3-month follow-up OCT examination. The primary outcome was the difference in early strut coverage between EES and BES groups and between OCT- and angiography-guided implantation groups. The secondary outcome was a composite of cardiac death, myocardial infarction, stent thrombosis, and major bleeding during the first 12 months post-procedure in patients receiving 3-month DAPT based on the presence of early strut coverage (≤6% uncovered) on 3-month follow-up OCT.. Three-month follow-up OCT data were acquired for 779 patients (87.1%). The median percentage of uncovered struts at 3 months was 8.9% and 8.2% in the EES and BES groups, respectively (p = 0.69) and was lower in the OCT-guided group (7.5%) than in the angiography-guided group (9.9%; p = 0.009). Favorable early strut coverage (≤6% uncovered strut) was observed in 320 of 779 patients (41.1%). At 12 months, the composite event rarely occurred in the 3-month (0.3%) or 12-month (0.2%) DAPT groups (p = 0.80).. OCT-guided DES implantation improved early strut coverage compared with angiography-guided DES implantation, with no difference in strut coverage between EES and BES groups. Short-term DAPT may be feasible in selected patients with favorable early strut coverage (Determination of the Duration of the Dual Antiplatelet Therapy by the Degree of the Coverage of The Struts on Optical Coherence Tomography From the Randomized Comparison Between Everolimus-eluting Stents Versus Biolimus A9-eluting Stents [DETECT-OCT]; NCT01752894). Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Thrombosis; Drug Therapy, Combination; Drug-Eluting Stents; Everolimus; Feasibility Studies; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Prosthesis Design; Republic of Korea; Risk Factors; Sirolimus; Stroke; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2018 |
Vascular response to biolimus A-9 eluting stent in patients with shorter and prolonged dual antiplatelet therapy: optical coherence tomography sub-study of the NIPPON trial.
Dual antiplatelet therapy (DAPT) with thienopyridine and aspirin is the standard care for the prevention of stent thrombosis. However, the optimal duration and effect of the duration of DAPT on intra-stent thrombus (IS-Th) formation are unknown. The NIPPON study (Nobori Dual Antiplatelet Therapy as Appropriate Duration) was an open label, randomized multicenter, assessor-blinded, trial designed to demonstrate the non-inferiority of shorter (6-month) DAPT to prolonged (18-month) DAPT, after biolimus A9 eluting stent implantation in 3773 patients at 130 sites in Japan. Among them, 101 patients were randomly allocated for an optical coherence tomography (OCT) sub-study to assess the difference of local IS-Th formation between the two groups. In addition to standard OCT parameters, the number of IS-Th formed was counted in each target stent at 8 months. Baseline patient characteristics were not different between the 6- and 18-month groups. IS-Th was detected in 9.8% of the cases and the presence of IS-Th was not significantly different between the two groups (10.9% in 6-month vs. 9.1% in 12-month, P = 0.76). Furthermore, the number of IS-Th formed was not significantly different between the two groups. This OCT sub-study was in line with the main NIPPON study which demonstrated the non-inferiority of 6-month DAPT to 18-month DAPT. Shorter DAPT duration did not promote progressive IS-Th formation at the mid-term time point. Topics: Aged; Aspirin; Coronary Artery Disease; Coronary Vessels; Dose-Response Relationship, Drug; Drug Therapy, Combination; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Pyridines; Retrospective Studies; Single-Blind Method; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Vascular Resistance | 2018 |
5-Year clinical follow-up of the COBRA (complex coronary bifurcation lesions: Randomized comparison of a strategy using a dedicated self-expanding biolimus A9-eluting stent vs. a culotte strategy using everolimus-eluting stents) study.
We evaluated healing responses with optical coherence tomography, and long-term clinical outcomes after treatment with a dedicated stent versus a conventional culotte technique.. Dedicated bifurcation stents have been proposed as an alternative treatment for coronary bifurcation lesions. The long-term performance of dedicated stents versus conventional dual-stent techniques for the treatment of complex coronary bifurcation lesions is unknown.. Forty patients with true coronary bifurcation lesions were randomized to treatment with a dedicated Axxess bifurcation stent in the proximal main vessel and additional Biomatrix stents in branches versus culotte stenting using Xience stents.. The percentage of uncovered struts in each bifurcation segment at 9 months (primary endpoint) was similar between groups. Five-year clinical follow-up was available for all patients and included major adverse cardiac events [MACE; a composite of cardiac death, myocardial infarction (MI) and ischemia-driven target lesion revascularization (TLR)], target-vessel (TVR) and non-target-vessel revascularization (non-TVR), non-TLR and stent thrombosis. At 5 years, in the culotte group, one patient had undergone TLR and another suffered a clinical MI, resulting in 10% MACE versus none in the Axxess group. TVR (5% vs. 10%, P = 0.54) and non-TVR (5% vs. 20%, P = 0.39) rates were similar between the Axxess and culotte groups, respectively. There was no stent thrombosis.. Compared with culotte stenting with Xience, complex coronary bifurcation stenting using a dedicated strategy combining the Axxess and Biomatrix stents results in similar stent strut coverage at 9 months, and excellent clinical outcomes at 5 years. Topics: Aged; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2018 |
The OCT-ORION Study: A Randomized Optical Coherence Tomography Study Comparing Resolute Integrity to Biomatrix Drug-Eluting Stent on the Degree of Early Stent Healing and Late Lumen Loss.
Durable polymers used in drug-eluting stents are considered a potential cause of hypersensitivity inflammatory response adversely affecting stent healing. Using a sequential follow-up with optical coherence tomography, we compared the differences in healing profiles of 2 drug-eluting stents with a biodegradable or durable polymer.. Sixty patients with multivessel disease were prospectively enrolled to receive both study stents, which were randomly assigned to 2 individual vessels, a Resolute Integrity zotarolimus-eluting stent with a durable BioLinx polymer and a BioMatrix NeoFlex Biolimus A9-eluting stent with a biodegradable polylactic acid polymer. Optical coherence tomography was performed at baseline, then in 5 randomly assigned monthly groups at 2 to 6 months, and at 9 months in all patients. The primary end point was the difference in optical coherence tomography strut coverage at 9 months. Key secondary end points included angiographic late lumen loss and composite major adverse cardiac events (cardiac death, myocardial infarction, target lesion revascularization, and definite or probable stent thrombosis) at 9 months. Resolute Integrity zotarolimus-eluting stent showed significantly better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent at 2 to 6 months (. Despite having a durable polymer, Resolute Integrity zotarolimus-eluting stent exhibited better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent having a biodegradable polymer; both showed similar antiproliferative efficacy. This novel, longitudinal, sequential optical coherence tomography protocol using each patient as own control could achieve conclusive results in small sample size.. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01742507. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Hong Kong; Humans; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2018 |
Establishment of healing profile and neointimal transformation in the new polymer-free biolimus A9-coated coronary stent by longitudinal sequential optical coherence tomography assessments: the EGO-BIOFREEDOM study.
This study aimed to establish the early healing and neointimal transformation profile of the new polymer-free BioFreedom stent through sequential optical coherence tomography (OCT) within the first nine months following stent implantation.. We randomly assigned 104 BFS recipients to one of five groups with angiography and OCT follow-up at 1, 2, 3, 4, or 5 months, together with another follow-up for all at nine months. The primary endpoint was the degree of OCT-detected strut coverage at nine months. From 1, 2, 3, 4, and 5 months, median neointimal strut coverage increased from 85.8, 87.0, 88.6, 96.8 to 97.1%, respectively, to 99.6% (IQR 98.2-99.9) at nine months. At nine months, median percent neointimal volume was 13.0% and angiographic late lumen loss was 0.21±0.30 mm. Major adverse cardiac events (MACE) were limited to one non-cardiac death, one non-ST-elevation myocardial infarction not related to BFS, and two target lesion revascularisations without stent thrombosis (MACE rate 4.0%).. Neointimal strut coverage of the BFS was rapid and the BFS was shown to be clinically safe and effective. Topics: Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Humans; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Prosthesis Design; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2018 |
Early Follow-Up Optical Coherence Tomographic Findings of Significant Drug-Eluting Stent Malapposition.
Using optical coherence tomography, we evaluated early follow-up findings of significant stent malapposition (SSM) in patients treated with second-generation drug-eluting stent.. From the DETECT-OCT randomized trial (Determination of the Duration of the Dual Antiplatelet Therapy by the Degree of the Coverage of the Struts on Optical Coherence Tomography From the Randomized Comparison Between Everolimus- Versus Biolimus-Eluting Stent), a total of 386 patients (390 lesions) who underwent both postintervention and 3-month follow-up optical coherence tomography examinations were included for the present analysis. SSM was defined as a stent that had a strut with a maximal wall-to-strut distance of ≥200 μm. Postintervention, SSM was detected in 175 lesions (44.9%), including 117 lesions with a maximal wall-to-strut distance of ≥200 to <400 μm and 58 lesions with a maximal wall-to-strut distance of ≥400 μm. As the implanted stent diameter-to-reference vessel diameter ratio grew, the risk of postintervention SSM dropped (odds ratio, 0.587; 95% CI, 0.367-0.941; P=0.0398). The optimal value that best separated SSM from non-SSM postintervention was a stent diameter-to-reference vessel diameter ratio of 1.0. At 3 months follow-up, the frequency of SSM decreased from 44.9% to 33.6% (131 lesions; P=0.0001), mainly driven by the decrease in lesions with a maximal wall-to-strut distance of ≥200 to <400 μm. As the maximal wall-to-strut distance on postintervention optical coherence tomography was larger, the risk of 3-month SSM increased (odds ratio, 1.607; 95% CI, 1.131-2.286; P=0.0284). The optimal value that best separated SSM from non-SSM at 3 months follow-up was a maximal wall-to-strut distance postintervention of 230 μm.. A spontaneous decrease in SSM was observed early in this qualified study with a large number of study patients treated with second-generation drug-eluting stent.. URL: https://www.clinicaltrials.gov . Unique identifier: NCT01752894. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Predictive Value of Tests; Prosthesis Design; Republic of Korea; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2018 |
Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease: Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable P
This analysis investigates the 5-year outcomes of the biodegradable polymer biolimus-eluting stent (BP-BES) and durable polymer everolimus-eluting stent (DP-EES) in an all-comers population undergoing percutaneous coronary intervention.. Recent 1- and 3-year results from randomized trials have indicated similar safety and efficacy outcomes of BP-BES and DP-EES. Whether benefits of the biodegradable polymer device arise over longer follow-up is unknown. Moreover, in-depth, prospective, long-term follow-up data on metallic drug-eluting stents with durable or biodegradable polymers are scarce.. The COMPARE II trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent) was a prospective, randomized, multicenter, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BP-BES or DP-EES. The pre-specified endpoint at 5 years was major adverse cardiac events, a composite of cardiac death, nonfatal myocardial infarction, or target vessel revascularization.. Five-year follow-up was available in 2,657 patients (98%). At 5 years, major adverse cardiac events occurred in 310 patients (17.3%) in the BP-BES group and 142 patients (15.6%) in the DP-EES group (p = 0.26). The rate of the combined safety endpoint all-cause death or myocardial infarction was 15.0% in the BP-BES group versus 14.8% in the DP-EES group (p = 0.90), whereas the efficacy measure target vessel revascularization was 10.6% versus 9.0% (p = 0.18), respectively. Interestingly, definite stent thrombosis rates did not differ between groups (1.5% for BP-BES vs. 0.9% for DP-EES; p = 0.17).. The 5-year analysis comparing biodegradable polymer-coated BES and the durable polymer-coated EES confirms the initial early- and mid-term results regarding similar safety and efficacy outcomes in this all-comers percutaneous coronary intervention population. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2017 |
Safety and Efficacy of Polymer-Free Biolimus A9-Coated Versus Bare-Metal Stents in Orally Anticoagulated Patients: 2-Year Results of the LEADERS FREE Oral Anticoagulation Substudy.
The aim of this study was to compare the performance of drug-coated stents (DCS) versus bare-metal stents (BMS) in patients who are candidates for long-term oral anticoagulation (OAC) after percutaneous coronary interventions.. The randomized controlled LEADERS FREE (A Randomized Clinical Evaluation of the BioFreedom™ Stent) trial demonstrated the superior safety and efficacy of a polymer-free biolimus A9 DCS compared with a similar BMS used with 1 month of dual antiplatelet therapy in 2,466 patients at high bleeding risk.. The 2 stents were compared in a pre-specified analysis of the 879 LEADERS FREE patients (35.6%) scheduled to remain on OAC after percutaneous coronary intervention. The primary safety endpoint was a composite of cardiac death, myocardial infarction, and stent thrombosis. The primary efficacy endpoint was the incidence of clinically driven target lesion revascularization.. Baseline characteristics of 448 DCS and 431 BMS recipients were similar, 78.8% had histories of atrial fibrillation, and 21% presented with acute coronary syndromes. Four hundred patients in the DCS group and 376 in the BMS group were discharged on OAC after percutaneous coronary intervention. At 2 years, for the DCS and BMS recipients, respectively, the incidence of clinically driven target lesion revascularization was 7.5% versus 11.2% (hazard ratio: 0.63; 95% confidence interval: 0.40 to 1.01; p = 0.0514), the safety endpoint was reached by 14.4% and 15.0% (p = NS), and the rates of major bleeding events (Bleeding Academic Research Consortium 3 to 5) were 10.7% and 12.9% (p = NS).. The efficacy advantage of DCS over BMS up to 2 years appears confirmed in patients on long-term OAC. Despite the very short course of dual antiplatelet therapy, both the DCS and BMS groups experienced similarly high rates of major bleeding. (A Randomized Clinical Evaluation of the BioFreedom™ Stent [Leaders Free]; NCT01623180). Topics: Acute Coronary Syndrome; Administration, Oral; Aged; Aged, 80 and over; Anticoagulants; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Double-Blind Method; Drug-Eluting Stents; Female; Hemorrhage; Humans; Kaplan-Meier Estimate; Male; Metals; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Proportional Hazards Models; Prosthesis Design; Risk Factors; Sirolimus; Stents; Time Factors; Treatment Outcome | 2017 |
Final five-year outcomes after implantation of biodegradable polymer-coated biolimus-eluting stents versus durable polymer-coated sirolimus-eluting stents.
Our aim was to report the long-term safety and efficacy of the biodegradable polymer-coated biolimus- eluting Nobori stent compared to the durable polymer-coated sirolimus-eluting CYPHER stent.. SORT OUT V randomised 2,468 patients 1:1 to the Nobori (n=1,229) versus the CYPHER stent (n=1,239). Clinically driven event detection based on Danish registries was used. The primary endpoint was a composite of safety (cardiac death, myocardial infarction, definite stent thrombosis) and efficacy (target vessel revascularisation). Individual components of the primary endpoint comprise the secondary endpoints. At five-year follow-up, the composite endpoint rate was found to be similar in patients treated with the two study stents (Nobori 182/1,229 [14.8%] vs. CYPHER 197/1,239 [15.8%]; odds ratio [OR] 0.93, 95% CI: 0.75-1.16; p=0.53). The rates of definite stent thrombosis were also found to be similar in patients treated with the two study stents (Nobori 23/1,229 [1.9%] vs. CYPHER 18/1,239 [1.5%]; OR 1.31, 95% CI: 0.70-2.47; p=0.40), as were the other secondary endpoints.. At five-year follow-up, the Nobori stent with a biodegradable polymer coating provided a similar safety and efficacy profile when compared to the durable polymer first-generation CYPHER stent. Topics: Absorbable Implants; Acute Coronary Syndrome; Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Restenosis; Coronary Stenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Incidence; Male; Middle Aged; Odds Ratio; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Recurrence; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2017 |
Intravascular imaging comparison of two metallic limus-eluting stents abluminally coated with biodegradable polymers: IVUS and OCT results of the DESTINY trial.
We sought to compare, by means of IVUS and OCT imaging, the performance of a novel sirolimus-eluting drug-eluting stent (DES) with biodegradable polymer (Inspiron™) to the Biomatrix™ DES. From the DESTINY trial, a total of 70 randomized patients (2:1) were enrolled in the IVUS substudy (Inspiron™, n = 46; Biomatrix™: n = 20) while 25 patients were evaluated with OCT (Inspiron™, n = 19; Biomatrix™: n = 06) at 9-month follow-up. The main endpoints were % of neointimal tissue obstruction (IVUS) and neointimal stut coverage (OCT) at 9 months. Patients treated with both DES had very little NIH formation at 9 months either by IVUS (% of NIH obstruction of 4.9 ± 4.1 % with Inspiron™ vs. 2.7 ± 2.9 % with Biomatrix™, p = 0.03) or by OCT (neointimal thickness of 144.2 ± 72.5 µm Inspiron™ vs. 115.0 ± 53.9 µm with Biomatrix™, p = 0.45). Regarding OCT strut-level assessment, again both devices showed excellent 9-month performance, with high rates of strut coverage (99.49 ± 1.01 % with Inspiron™ vs. 97.62 ± 2.21 % with Biomatrix™, p < 0.001) and very rare malapposition (0.29 ± 1.06 % with Inspiron™ vs. 0.53 ± 0.82 % with Biomatrix™, p = 0.44). Patients with any uncovered struts were more frequently identified in the Biomatrix™ group (9.78 ± 7.13 vs. 2.29 ± 3.91 %, p < 0.001). In the present study, midterm IVUS and OCT evaluations showed that both new generation DES with biodegradable polymer were effective in terms of suppressing excessive neointimal response, with very high rates of apposed and covered struts, suggesting a consistent and benign healing pattern. Topics: Absorbable Implants; Cardiovascular Agents; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Humans; Metals; Neointima; Percutaneous Coronary Intervention; Polymers; Predictive Value of Tests; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2017 |
Comparison of Durable-Polymer Zotarolimus-Eluting and Biodegradable-Polymer Biolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease: 3-Year Clinical Outcomes in the Randomized SORT OUT VI Trial.
The authors sought to compare the safety and efficacy of the biocompatible durable-polymer zotarolimus-eluting stent with the biodegradable-polymer biolimus-eluting stent in unselected coronary patients.. Biodegradable-polymer biolimus-eluting stents are superior to first-generation durable-polymer drug-eluting stents in long-term randomized all-comer trials. Long-term data comparing them to second-generation durable-polymer drug-eluting stents are lacking.. The study was a randomized, multicenter, all-comer, noninferiority trial in patients with chronic stable coronary artery disease or acute coronary syndromes and at least 1 coronary artery lesion requiring treatment with a drug-eluting stent. Endpoints included major adverse cardiac events (MACE), a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion) and efficacy (target lesion revascularization); the individual endpoints of MACE; all-cause mortality; any myocardial infarction; target vessel revascularization; and definite or probable stent thrombosis at 36 months.. From March 2011 to August 2012, 2,999 patients were randomly assigned (1:1) to receive either the zotarolimus-eluting (1,502 patients) or the biolimus-eluting (1,497 patients) stent. At 3-year follow-up, MACE occurred in 128 (8.6%) patients assigned to the durable-polymer zotarolimus-eluting stent and in 144 (9.6%) assigned to the biodegradable-polymer biolimus-eluting stent (p = 0.36). Occurrence of cardiac death (2.7% vs. 3.4%), myocardial infarction not clearly attributable to a non-target lesion (2.7% vs. 2.5%), and target lesion revascularization (5.4% vs. 5.5%) did not differ significantly between the 2 groups. Definite very late stent thrombosis occurred in 6 (0.4%) patients assigned to the durable-polymer zotarolimus-eluting stent and in 10 (0.7%) assigned to the biodegradable-polymer biolimus-eluting stent (p = 0.33).. At 3-year follow-up, the durable-polymer zotarolimus-eluting stent and the biodegradable-polymer biolimus-eluting stent were similar in clinical outcome, with no significant difference in safety and efficacy outcomes, including stent thrombosis. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Denmark; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Proportional Hazards Models; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2017 |
First generation versus second generation drug-eluting stents for the treatment of bifurcations: 5-year follow-up of the LEADERS all-comers randomized trial.
Historically, percutaneous coronary intervention (PCI) of bifurcation lesions was associated with worse procedural and clinical outcomes when compared with PCI of non-bifurcation lesions. Newer generation drug-eluting stents (DES) might improve long-term clinical outcomes after bifurcation PCI.. The LEADERS trial was a 10-center, assessor-blind, non-inferiority, all-comers trial, randomizing 1,707 patients to treatment with a biolimus A9(TM) -eluting stent (BES) with an abluminal biodegradable polymer or a sirolimus-eluting stent (SES) with a durable polymer (ClinicalTrials.gov Identifier: NCT00389220). Five-year clinical outcomes were compared between patients with and without bifurcation lesions and between BES and SES in the bifurcation lesion subgroup. There were 497 (29%) patients with at least 1 bifurcation lesion (BES = 258; SES = 239). At 5-year follow-up, the composite endpoint of cardiac death, myocardial infarction (MI) and clinically-indicated (CI) target vessel revascularization (TVR) was observed more frequently in the bifurcation group (26.6% vs. 22.4%, P = 0.049). Within the bifurcation lesion subgroup, no differences were observed in (cardiac) death or MI rates between BES and SES. However, CI target lesion revascularization (TLR) (10.1% vs. 15.9%, P = 0.0495), and CI TVR (12.0% vs. 19.2%, P = 0.023) rates were significantly lower in the BES group. Definite/probable stent thrombosis (ST) rate was numerically lower in the BES group (3.1% vs. 5.9%, P = 0.15). Very late (>1 year) definite/probable ST rates trended to be lower with BES (0.4% vs. 3.1%, P = 0.057).. In the treatment of bifurcation lesions, use of BES led to superior long-term efficacy compared with SES. Safety outcomes were comparable between BES and SES, with an observed trend toward a lower rate of very late definite/probable ST between 1 and 5 years with the BES. © 2015 Wiley Periodicals, Inc. Topics: Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Europe; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2016 |
Polymer-Free Biolimus A9-Coated Stents in the Treatment of De Novo Coronary Lesions: 4- and 12-Month Angiographic Follow-Up and Final 5-Year Clinical Outcomes of the Prospective, Multicenter BioFreedom FIM Clinical Trial.
The purpose of this study was to evaluate the efficacy and long-term outcomes of a novel polymer/carrier-free drug-coated stent (DCS) in patients with de novo coronary lesions.. The BioFreedom (BFD) DCS incorporates a low-profile, stainless-steel platform, with a surface that has been modified to create a selectively microstructured abluminal surface that allows adhesion and further release of Biolimus A9 (Biosensors Europe SA, Morges, Switzerland).. A total of 182 patients (183 lesions) were randomized into a 1:1:1 ratio for treatment with BFD "standard dose" (BFD) or BFD "low dose" (BFD-LD) versus first-generation paclitaxel-eluting stents (PES) at 4 sites in Germany.. Baseline and procedural characteristics were well matched. At 4-month angiographic follow-up (Cohort 1, n = 75), in-stent late lumen loss (LLL) was significantly lower with BFD and BFD-LD versus PES (0.08 and 0.12 mm vs. 0.37 mm, respectively; p < 0.0001 for BFD vs. PES, and p = 0.002 for BFD-LD vs. PES). At 12 months (Cohort 2, n = 107), in-stent LLL (primary endpoint) was 0.17 mm in BFD versus 0.35 mm in PES (p = 0.001 for noninferiority; p = 0.11 for superiority); however, the BFD-LD (0.22 mm) did not reach noninferiority (p = 0.21). At 5 years (175 of 182), there were no significant differences in major adverse cardiac events (23.8%, 26.4%, and 20.3%) and clinically indicated target lesion revascularization (10.8%, 13.4%, and 10.2%) for BFD, BFD-LD, and PES, respectively; also, there was no definite/probable stent thrombosis reported.. The BFD, but not the BFD-LD, demonstrated noninferiority versus PES in terms of in-stent LLL, a surrogate of neointimal hyperplasia, at 12-month follow-up. At 5 years, clinical event rates were similar, without occurrence of stent thrombosis in all groups. (BioFreedom FIM Clinical Trial; NCT01172119). Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Germany; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Neointima; Paclitaxel; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Risk Factors; Single-Blind Method; Sirolimus; Stainless Steel; Surface Properties; Time Factors; Treatment Outcome | 2016 |
Vascular response to everolimus- and biolimus-eluting coronary stents versus everolimus-eluting bioresorbable scaffolds--an optical coherence tomography substudy of the EVERBIO II trial.
Head-to-head optical coherence tomography (OCT) data comparing metallic stents with bioresorbable vascular scaffolds (BVS) are lacking. This study assessed vascular healing at 9-month follow-up after implantation of everolimus- and biolimus-eluting stents (EES; BES) and everolimus-eluting BVS.. OCT was performed in 74 patients enrolled in the EVERBIO II (NCT01711931) trial (23 with EES: 26 lesions, 7 625 struts; 23 with BES: 26 lesions, 6 140 struts; 28 with BVS: 33 lesions, 10 891 struts). OCT images were acquired using the pullback and nonocclusive flushing technique and analysed offline.. BVS demonstrated fewer uncovered struts per patient (12 ± 27 [3.8 ± 8.4%] vs 59 ± 55 [21.8 ± 13.7%] in the EES&BES group, p <0.001), and thicker neointimal hyperplasia (BVS 102 ± 44 µm vs EES&BES 66 ± 36 µm, p <0.01). There was no significant difference with regard to malapposed struts (2.1 ± 2.7% in the BVS vs 4.4 ± 8.8% in the EES&BES group, p = 0.41). In a predefined signal intensity scale, quantitative analysis of the "key component" (black) revealed lower intensity in BVS than EES&BES (14 ± 23% vs 13 ± 12%, p = 0.007). Intensity was lower in polylactide-containing stents (BVS&BES) than in EES (15 ± 19% vs 10 ± 10%, p <0.001).. BVS has fewer uncovered struts and presents with a thicker neointimal coverage compared with EES&BES. It is not known whether this improved capping correlates with superior vascular healing. Polylactide-containing stents (BVS and BES) demonstrate lower peristrut intensity compared with EES. Topics: Absorbable Implants; Aged; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Percutaneous Coronary Intervention; Single-Blind Method; Sirolimus; Tissue Scaffolds; Tomography, Optical Coherence; Treatment Outcome | 2016 |
Complex bifurcation lesions: Randomized comparison of a fully bioresorbable modified t stenting strategy versus bifurcation reconstruction with a dedicated self-expanding stent in combination with bioresorbable scaffolds, an OCT study: Rationale and desig
There is an ongoing controversy regarding the efficacy and safety of different percutaneous stenting techniques for coronary bifurcation lesions needing >1 stent. The promise of safe vessel restoration with bioresorbable scaffolds (BRS) may not be transferable to complex double BRS bifurcation techniques, and permanent metallic scaffolding of the bifurcation core may be needed. We identified modified-T stenting as the most promising fully bioresorbable 2-stent strategy in a preclinical setting. The objective of this study is to assess acute performance and compare long-term vessel healing with this strategy, versus an approach combining BRS with a dedicated metallic drug-eluting bifurcation stent.. In a single center, 60 consecutive patients with true and complex coronary bifurcation lesions will be randomly assigned to treatment with the dedicated self-expanding Axxess. To date the use of Absorb Topics: Absorbable Implants; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Middle Aged; Prosthesis Design; Sirolimus; Tissue Scaffolds; Tomography, Optical Coherence; Treatment Outcome | 2016 |
Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention: The SORT OUT VII Trial.
Coronary drug-eluting stents with biodegradable polymers have been designed to improve safety and efficacy.. The Scandinavian Organization for Randomized Trials With Clinical Outcome (SORT OUT) VII trial-a large-scale registry-based randomized, multicenter, single-blind, 2-arm, noninferiority trial-compared 2 biodegradable polymer drug-eluting stents: the thin-strut cobalt-chromium sirolimus-eluting Orsiro stent and the stainless steel biolimus-eluting Nobori stent in an all-comer patient population. The primary end point target lesion failure was a composite of cardiac death, myocardial infarction (not related to other than index lesion), or target lesion revascularization within 1 year, analyzed by intention to treat (noninferiority margin of 3.0%). Clinically driven event detection based on Danish registries was used. A total of 1261 patients were assigned to receive the sirolimus-eluting stent (1590 lesions) and 1264 patients to the biolimus-eluting stent (1588 lesions). At 1 year, the composite end point target lesion failure occurred in 48 patients (3.8%) in the sirolimus-eluting group and in 58 patients (4.6%) in the biolimus-eluting group (absolute risk difference, -0.78% [upper limit of 1-sided 95% confidence interval, 0.61%]; P<0.0001). Rates of definite stent thrombosis occurred in 5 (0.4%) of the sirolimus-eluting group compared with 15 (1.2%) biolimus-eluting stent-treated patients (rate ratio, 0.33; 95% confidence interval, 0.12-0.92; P=0.034), which largely was attributable to a lower risk of subacute definite stent thrombosis: 0.1% versus 0.6% (rate ratio, 0.12; 95% confidence interval, 0.02-1.00; P=0.05).. The thin-strut sirolimus-eluting Orsiro stent was noninferior to the biolimus-eluting Nobori stent in unselected patients for target lesion failure at 1 year.. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01879358. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Chromium Alloys; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Intention to Treat Analysis; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Registries; Risk Factors; Scandinavian and Nordic Countries; Single-Blind Method; Sirolimus; Stainless Steel; Time Factors; Treatment Outcome | 2016 |
Long-term efficacy and safety of biodegradable-polymer biolimus-eluting stents: main results of the Basel Stent Kosten-Effektivitäts Trial-PROspective Validation Examination II (BASKET-PROVE II), a randomized, controlled noninferiority 2-year outcome tria
Biodegradable-polymer drug-eluting stents (BP-DES) were developed to be as effective as second-generation durable-polymer drug-eluting stents (DP-DES) and as safe >1 year as bare-metal stents (BMS). Thus, very late stent thrombosis (VLST) attributable to durable polymers should no longer appear.. To address these early and late aspects, 2291 patients presenting with acute or stable coronary disease needing stents ≥3.0 mm in diameter between April 2010 and May 2012 were randomly assigned to biolimus-A9-eluting BP-DES, second-generation everolimus-eluting DP-DES, or thin-strut silicon-carbide-coated BMS in 8 European centers. All patients were treated with aspirin and risk-adjusted doses of prasugrel. The primary end point was combined cardiac death, myocardial infarction, and clinically indicated target-vessel revascularization within 2 years. The combined secondary safety end point was a composite of VLST, myocardial infarction, and cardiac death. The cumulative incidence of the primary end point was 7.6% with BP-DES, 6.8% with DP-DES, and 12.7% with BMS. By intention-to-treat BP-DES were noninferior (predefined margin, 3.80%) compared with DP-DES (absolute risk difference, 0.78%; -1.93% to 3.50%; P for noninferiority 0.042; per protocol P=0.09) and superior to BMS (absolute risk difference, -5.16; -8.32 to -2.01; P=0.0011). The 3 stent groups did not differ in the combined safety end point, with no decrease in events >1 year, particularly VLST with BP-DES.. In large vessel stenting, BP-DES appeared barely noninferior compared with DP-DES and more effective than thin-strut BMS, but without evidence for better safety nor lower VLST rates >1 year. Findings challenge the concept that durable polymers are key in VLST formation.. http://www.clinicaltrials.gov. Unique identifier: NCT01166685. Topics: Absorbable Implants; Aged; Anti-Inflammatory Agents; Aspirin; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Female; Humans; Kaplan-Meier Estimate; Longitudinal Studies; Male; Metals; Middle Aged; Piperazines; Platelet Aggregation Inhibitors; Polymers; Prasugrel Hydrochloride; Purinergic P2Y Receptor Antagonists; Single-Blind Method; Sirolimus; Stents; Switzerland; Thiophenes; Treatment Outcome | 2015 |
Five-year clinical outcome of the Nobori drug-eluting coronary stent system in the treatment of patients with coronary artery disease: final results of the NOBORI 1 trial.
To assess the safety and performance of the Nobori drug-eluting stent with biodegradable polymer versus the TAXUS drug-eluting stent with permanent polymer, in the treatment of patients with de novo coronary artery lesions.. NOBORI 1 was a multicentre, randomised (2:1), prospective, controlled, clinical trial which enrolled 363 patients (238 Nobori and 125 TAXUS) with up to two de novo lesions in two epicardial vessels. The primary endpoint was in-stent late loss at nine months, while secondary endpoints included safety and efficacy up to five years. At five years, clinical data were available for 350 patients (96%). There were no differences in the composite of death and myocardial infarction (10.9% vs. 11.2%) and target lesion failure (9.2% and 10.4%), while ischaemia- and non-ischaemia-driven target lesion revascularisations were less frequent in the Nobori (6.3%) than in the TAXUS arm (16.0%). The rates of stent thrombosis (definite and probable according to the ARC definitions) were 0.0% and 3.2%, in the Nobori and TAXUS stents, respectively (p=0.014).. Five years after implantation, the Nobori DES resulted in durable treatment effects with very low TLR and no stent thrombosis. The study was not powered to assess the differences in clinical endpoints. These data are hypothesis-generating. Topics: Absorbable Implants; Aged; Coronary Artery Bypass; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Female; Graft Occlusion, Vascular; Humans; Male; Middle Aged; Mortality; Myocardial Infarction; Myocardial Revascularization; Percutaneous Coronary Intervention; Prosthesis Design; Sirolimus; Treatment Outcome | 2015 |
Comparison of everolimus- and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds.
The first CE-approved bioresorbable vascular scaffold (BVS) is effective at treating simple lesions and stable coronary artery disease, but it has yet to be assessed versus the best-in-class drug-eluting stents (DES).. This study sought to compare the performance of a BVS with that of everolimus-eluting stents (EES) and biolimus-eluting stents (BES) in all-comer patients.. The EVERBIO II (Comparison of Everolimus- and Biolimus-Eluting Stents With Everolimus-Eluting Bioresorbable Vascular Scaffold Stents II) trial was a single-center, assessor-blinded study of 240 patients randomly assigned in a 1:1:1 ratio to EES, BES, or BVS. The only exclusion criterion was a reference vessel diameter >4.0 mm, which precluded treatment with BVS. The primary endpoint was angiographic late lumen loss (LLL) at 9 months. Secondary endpoints included patient-oriented major acute coronary events (MACE) (death, myocardial infarction [MI], and any revascularization), device-oriented MACE (cardiac death, MI, and target lesion revascularization), and stent thrombosis at the 9-month clinical follow-up.. Follow-up angiography was performed in 216 patients (90.7%) at 9 months. In-stent LLL was similar between patients treated with BVS (0.28 ± 0.39 mm) and those treated with EES/BES (0.25 ± 0.36 mm; p = 0.30). Clinical outcomes were similar at 9 months: the patient-oriented MACE rate was 27% in BVS and 26% in the EES/BES group (p = 0.83) and the device-oriented MACE rate was 12% in BVS and 9% in the EES/BES group (p = 0.6).. New-generation metallic DES (EES/BES) were not superior to BVS in terms of angiographic LLL and clinical outcomes. (Comparison of Everolimus- and Biolimus-Eluting Stents With Everolimus-Eluting Bioresorbable Vascular Scaffold Stents [EVERBIO II]; NCT01711931). Topics: Absorbable Implants; Aged; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Male; Materials Testing; Middle Aged; Percutaneous Coronary Intervention; Postoperative Complications; Sirolimus; Tissue Scaffolds; Treatment Outcome | 2015 |
Randomized comparison of a sirolimus-eluting Orsiro stent with a biolimus-eluting Nobori stent in patients treated with percutaneous coronary intervention: Rationale and study design of the Scandinavian Organization for Randomized Trials with Clinical Out
Third-generation coronary drug-eluting stents (DES) with biodegradable polymers have been designed to improve safety and efficacy. We designed a large scale registry-based randomized clinical trial to compare 2 third-generation DES: a thin strut, cobalt-chromium DES with silicon carbide-coating releasing sirolimus from a biodegradable polymer (O-SES, Orsiro; Biotronik, Bülach, Switzerland) with the stainless steel biodegradable polymer biolimus-eluting Nobori stents (N-BES, Nobori; Terumo, Tokyo, Japan) in an all-comer patient population.. The multicenter SORT OUT VII trial (NCT01879358) randomly assigned 2,530 patients to treatment with biodegradable polymer O-SES or biodegradable polymer N-BES at 3 sites in Western Denmark. Patients were eligible, if they were ≥18 years old; had chronic stable coronary artery disease or acute coronary syndromes; and ≥1 coronary lesion with >50% diameter stenosis, requiring treatment with a DES. The primary end point target lesion failure is a composite of cardiac death, myocardial infarction (not related to other than index lesion), or target lesion revascularization within 12 months. Clinically, driven event detection based on Danish registries will be used. An event rate of 6.5% is assumed in each stent group. With a sample size of 1,157 patients in each treatment arm, a 2-group large-sample normal approximation test of proportions with a 1-sided 5% significance level will have 90% power to detect noninferiority of the O-SES compared with the N-BES with a predetermined noninferiority margin of 3.0%.. The SORT OUT VII trial will determine whether the biodegradable polymers O-SES is noninferior to the N-BES with respect to driven event. Topics: Coronary Artery Disease; Denmark; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Percutaneous Coronary Intervention; Prosthesis Design; Retrospective Studies; Single-Blind Method; Sirolimus; Societies, Medical; Treatment Outcome | 2015 |
Metallic Limus-Eluting Stents Abluminally Coated with Biodegradable Polymers: Angiographic and Clinical Comparison of a Novel Ultra-Thin Sirolimus Stent Versus Biolimus Stent in the DESTINY Randomized Trial.
To evaluate the outcomes of patients treated with a new drug-eluting stent formulation with low doses of sirolimus, built in an ultra-thin-strut platform coated with biodegradable abluminal coating.. This study is a randomized trial that tested the main hypothesis that the angiographic late lumen loss of the novel sirolimus-eluting stent is noninferior compared with commercially available biolimus-eluting stent. A final study population comprising 170 patients with one or two de novo lesions was randomized in the ratio 2:1 for sirolimus-eluting stent or biolimus-eluting stent, respectively. The primary endpoint was 9-month angiographic in-stent late lumen loss. Adverse clinical events were prospectively collected for 1 year.. After 9 months, the novel sirolimus-eluting stent was shown noninferior compared with the biolimus stent for the primary endpoint (angiographic in-stent late lumen loss: 0.20 ± 0.29 mm vs. 0.15 ± 0.20 mm, respectively; P value for noninferiority <0.001). The 1-year incidence of death, myocardial infarction, repeat revascularization, and stent thrombosis remained low and not significantly different between the groups.. The present randomized trial demonstrates that the tested novel sirolimus-eluting stent was angiographically noninferior in comparison with a last-generation biolimus-eluting stent. Topics: Absorbable Implants; Aged; Brazil; Cardiovascular Agents; Coated Materials, Biocompatible; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome | 2015 |
Polymer-free Drug-Coated Coronary Stents in Patients at High Bleeding Risk.
Patients at high risk for bleeding who undergo percutaneous coronary intervention (PCI) often receive bare-metal stents followed by 1 month of dual antiplatelet therapy. We studied a polymer-free and carrier-free drug-coated stent that transfers umirolimus (also known as biolimus A9), a highly lipophilic sirolimus analogue, into the vessel wall over a period of 1 month.. In a randomized, double-blind trial, we compared the drug-coated stent with a very similar bare-metal stent in patients with a high risk of bleeding who underwent PCI. All patients received 1 month of dual antiplatelet therapy. The primary safety end point, tested for both noninferiority and superiority, was a composite of cardiac death, myocardial infarction, or stent thrombosis. The primary efficacy end point was clinically driven target-lesion revascularization.. We enrolled 2466 patients. At 390 days, the primary safety end point had occurred in 112 patients (9.4%) in the drug-coated-stent group and in 154 patients (12.9%) in the bare-metal-stent group (risk difference, -3.6 percentage points; 95% confidence interval [CI], -6.1 to -1.0; hazard ratio, 0.71; 95% CI, 0.56 to 0.91; P<0.001 for noninferiority and P=0.005 for superiority). During the same time period, clinically driven target-lesion revascularization was needed in 59 patients (5.1%) in the drug-coated-stent group and in 113 patients (9.8%) in the bare-metal-stent group (risk difference, -4.8 percentage points; 95% CI, -6.9 to -2.6; hazard ratio, 0.50; 95% CI, 0.37 to 0.69; P<0.001).. Among patients at high risk for bleeding who underwent PCI, a polymer-free umirolimus-coated stent was superior to a bare-metal stent with respect to the primary safety and efficacy end points when used with a 1-month course of dual antiplatelet therapy. (Funded by Biosensors Europe; LEADERS FREE ClinicalTrials.gov number, NCT01623180.). Topics: Aged; Combined Modality Therapy; Coronary Artery Disease; Double-Blind Method; Drug-Eluting Stents; Female; Humans; Immunosuppressive Agents; Kaplan-Meier Estimate; Male; Middle Aged; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Polymers; Prosthesis Design; Sirolimus; Stents | 2015 |
Comparison of everolimus-eluting and biolimus-eluting coronary stents with everolimus-eluting bioresorbable scaffold: study protocol of the randomized controlled EVERBIO II trial.
Second-generation everolimus-eluting stents (EES) and third generation biolimus-eluting stents (BES) have been shown to be superior to first-generation paclitaxel-eluting stents (PES) and second-generation sirolimus-eluting stents (SES). However, neointimal proliferation and very late stent thrombosis is still an unresolved issue of drug-eluting stent (DES) implantation overall. The Absorb™ (Abbott Vascular, Abbott Park, IL, USA) is the first CE approved DES with a bioresorbable vascular scaffold (BVS) thought to reduce long-term complication rates. The EVERBIO II trial was set up to compare the BVS safety and efficacy with both EES and BES in all patients viable for inclusion.. The EVERBIO II trial is a single-center, assessor-blinded, randomized trial. The study population consists of all patients aged≥18 years old undergoing percutaneous coronary intervention. Exclusion criterion is where the lesion cannot be treated with BVS (reference vessel diameter>4.0 mm). A total of 240 patients will be enrolled and randomly assigned into 3 groups of 80 with either BVS, EES or BES implantation. All patients will undergo a follow-up angiography study at 9 months. Clinical follow-up for up to 5 years will be conducted by telephone. The primary endpoint is in-segment late lumen loss at 9 months measured by quantitative coronary angiography. Secondary endpoints are patient-oriented major adverse cardiac event (MACE) (death, myocardial infarction and target-vessel revascularization), device-oriented MACE (cardiac death, myocardial infarction and target-lesion revascularization), stent thrombosis according to ARC and binary restenosis at follow-up 12 months angiography.. EVERBIO II is an independent, randomized study, aiming to compare the clinical efficacy, angiographic outcomes and safety of BVS, EES and BES in all comer patients.. The trial listed in clinicaltrials.gov as NCT01711931. Topics: Absorbable Implants; Cardiovascular Agents; Clinical Protocols; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Humans; Myocardial Infarction; Percutaneous Coronary Intervention; Prosthesis Design; Research Design; Sirolimus; Switzerland; Time Factors; Tissue Scaffolds; Treatment Outcome | 2014 |
Multicenter randomized trial of 3-month cilostazol use in addition to dual antiplatelet therapy after biolimus-eluting stent implantation for long or multivessel coronary artery disease.
There are conflicting data on the use of cilostazol as triple antiplatelet therapy (TAPT) for improving clinical outcomes after drug-eluting stent implantation. We aimed to evaluate whether 3-month use of cilostazol in addition to dual antiplatelet therapy (DAPT) improved clinical outcomes in patients with long or multivessel coronary artery disease (CAD) after biolimus-eluting stent (BES) implantation.. Patients (n = 630) who had been successfully treated with BES implantation for lesions with ≥28 mm in stent length or ≥2 stents for different coronary arteries were enrolled in this prospective randomized multicenter trial. All patients were randomly assigned to receive either DAPT (aspirin and clopidogrel for 12 months, n = 314) or TAPT (DAPT plus 3-month cilostazol use, n = 316). The primary end point was a device-oriented composite consisting of cardiac death, myocardial infarction (not clearly attributable to a nontarget vessel), and ischemia-driven target lesion revascularization at 1-year follow-up.. A total of 314 patients in DAPT and 308 patients in TAPT were analyzed. Multivessel CAD was present in 65.7% of patients. Stents ≥28 mm in length were implanted in 58.1% of lesions. There were no significant differences in baseline and angiographic characteristics between the 2 groups. The primary end point was similar between the 2 groups (2.3% in DAPT vs 1.9% in TAPT, log-rank P = .799).. In patients treated with BES implantation for long or multivessel CAD, 3 months of cilostazol use in addition to DAPT did not improve clinical outcome at 1-year follow-up. Topics: Aged; Cilostazol; Clopidogrel; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Dose-Response Relationship, Drug; Drug Therapy, Combination; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Platelet Aggregation Inhibitors; Prospective Studies; Sirolimus; Tetrazoles; Ticlopidine; Time Factors; Treatment Outcome | 2014 |
Baseline and 9 months IVUS analysis of the bifurcation-dedicated biolimus A9-eluting Axxess stent system: the DIVERGE IVUS substudy.
Percutaneous treatment of complex coronary bifurcation lesions remains challenging, even in the drug-eluting stent era. We sought to evaluate the baseline and 9 months intravascular ultrasound (IVUS) analysis of the Axxess™ stent, a self-expanding, Biolimus A9™-eluting, and dedicated bifurcation stent.. We enrolled the first 76 patients from selected sites of the 302 patients large DIVERGE trial (a prospective, single-arm, multicenter trial evaluating the safety and efficacy of the Axxess stent). Both baseline and 9 months IVUS images were collected for serial two-dimensional (2D) and 3D analysis. A minimal amount and a low percentage of neointimal volume index were seen in the Axxess stent at 9 months (0.4 ± 0.6 mm(3) /mm and 4.3 ± 5.2%, respectively). Vessel, lumen, and stent volume indices increased significantly (respectively, 17.0 ± 3.6 to 18.9 ± 3.7 mm(3) /mm, P < 0.0001; 7.3 ± 2.0 to 9.2 ± 2.5 mm(3) /mm, P < 0.0001; and 7.4 ± 2.0 to 9.6 ± 2.6 mm(3) /mm, P < 0.0001). This resulted in minimum lumen area (MLA) enlargement (6.1 ± 1.9 to 7.2 ± 2.3 mm(2) , P < 0.0001), whereas peristent plaque area decreased (8.7 ± 2.5 to 8.5 ± 2.1 mm(3) /mm, P = 0.016). At 9 months, 16 (26%) incomplete stent apposition (ISA) persisted from baseline, while six resolved (9.7%). Only one (2%) ISA was late acquired. In the additional distal sirolimus-eluting stents, MLA decreased from 4.3 ± 1.1 to 4.1 ± 1.2 mm(2) (P = 0.04) at 9 months for the main branch, and from 3.4 ± 1.2 to 3.2 ± 1.2 mm(2) (P = 0.09) for the side branch.. The dedicated bifurcation Axxess stent system demonstrates significant stent volume increase with minimal neointimal formation and a low incidence of late-acquired ISA at 9 months. Topics: Adolescent; Adult; Aged; Aged, 80 and over; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Prospective Studies; Prosthesis Design; Reproducibility of Results; Sirolimus; Time Factors; Treatment Outcome; Ultrasonography, Interventional; Young Adult | 2014 |
Comparison of biolimus A9-eluting (Nobori) and everolimus-eluting (Promus Element) stents in patients with de novo native long coronary artery lesions: a randomized Long Drug-Eluting Stent V trial.
Procedural and clinical outcomes still remain unfavorable for patients with long coronary lesions who undergo percutaneous coronary intervention. The current study, therefore, evaluated 2 innovative drug-eluting stents for the management of long-lesion coronary artery disease.. This randomized, multicenter, prospective trial, called the Long Drug-Eluting Stent (LONG-DES) V trial, compared the biodegradable polymer-based biolimus A9-eluting stent (BES) and the durable polymer-based platinum chromium everolimus-eluting stent (PtCr-EES) in 500 patients with long (≥ 25 mm) coronary lesions. The primary end point of the trial was in-segment late luminal loss at the 9-month angiographic follow-up. The BES and PtCr-EES groups had similar baseline characteristics, with a slightly shorter lesion length in the BES group versus the PtCr-EES group (29.24 ± 12.17 versus 32.27 ± 13.84 mm; P = 0.016). In-segment late luminal loss was comparable between the 2 groups at the 9-month angiographic follow-up (BES, 0.14 ± 0.38 versus PtCr-EES, 0.11 ± 0.37 mm; difference, 0.031; 95% confidence interval, -0.053 to 0.091; P = 0.03 for a noninferiority margin of 0.11, P = 0.45 for superiority), as was in-stent late luminal loss (0.20 ± 0.41 versus 0.24 ± 0.38 mm; P = 0.29). The incidence of in-segment (6.1% versus 4.9%; P = 0.63) and in-stent (3.7% versus 4.9%; P = 0.59) binary restenosis was also similar between the groups. There was no significant between-group difference in the rate of composite outcome of death, myocardial infarction, and target vessel revascularization (41, 16.7% in BES versus 42, 16.5% in PtCr-EES; P=0.94).. BES and PtCr-EES implantation showed analogous angiographic and clinical outcomes for patients with de novo long coronary lesions.. http://www.clinicaltrials.gov. Unique identifier: NCT01186120. Topics: Aged; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Incidence; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Single-Blind Method; Sirolimus; Survival Rate; Thrombosis; Treatment Outcome | 2014 |
Biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent: a randomized, controlled, noninferiority trial.
NEXT (NOBORI Biolimus-Eluting Versus XIENCE/PROMUS Everolimus-Eluting Stent Trial) was designed for evaluating the noninferiority of a biolimus-eluting stent (BES) relative to an everolimus-eluting stent (EES) in terms of target lesion revascularization (TLR) at 1 year.. Efficacy and safety data comparing biodegradable polymer BES with durable polymer cobalt-chromium EES are currently limited.. The NEXT trial is a prospective, multicenter, randomized, open-label, noninferiority trial comparing BES with EES. Between May and October 2011, 3,235 patients were randomly assigned to receive either BES (n = 1,617) or EES (n = 1,618).. At 1 year, the primary efficacy endpoint of TLR occurred in 67 patients (4.2%) in the BES group, and in 66 patients (4.2%) in the EES group, demonstrating noninferiority of BES relative to EES (p for noninferiority <0.0001, and p for superiority = 0.93). Cumulative incidence of definite stent thrombosis was low and similar between the 2 groups (0.25% vs. 0.06%, p = 0.18). An angiographic substudy enrolling 528 patients (BES: n = 263, and EES: n = 265) demonstrated noninferiority of BES relative to EES regarding the primary angiographic endpoint of in-segment late loss (0.03 ± 0.39 mm vs. 0.06 ± 0.45 mm, p for noninferiority <0.0001, and p for superiority = 0.52) at 266 ± 43 days after stent implantation.. One-year clinical and angiographic outcome after BES implantation was noninferior to and not different from that after EES implantation in a mostly stable coronary artery disease population. One-year clinical outcome after both BES and EES use was excellent, with a low rate of TLR and extremely low rate of stent thrombosis. Topics: Absorbable Implants; Aged; Aged, 80 and over; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Male; Middle Aged; Polymers; Prospective Studies; Radiography; Single-Blind Method; Sirolimus; Treatment Outcome | 2013 |
Optical coherence tomography analysis of strut coverage in biolimus- and sirolimus-eluting stents: 3-month and 12-month serial follow-up.
No randomized studies have been conducted to investigate serial changes in optical coherence tomography (OCT) analyses following implantation of biolimus-A9-eluting stents (BES) and sirolimus-eluting stents (SES).. A total of 60 patients fulfilling the study criteria were randomly assigned into BES (n=30) and SES (n=30) implantation groups. Serial OCT evaluation at post-procedure, 3- and 12-month follow-up was performed in 46 patients [BES (n=22) and SES (n=24)]. OCT analyses were compared according to the type of stents and the follow-up time intervals. The percentage of uncovered struts was defined as the ratio of uncovered struts to total struts in all cross-sections. The primary endpoint was the percentage change (Δ) of uncovered struts in the 3- and 12-month follow-up samples.. The percentage of uncovered struts at the 3-month time period was not significantly different in the BES and SES groups; the median value (interquartile range) was 14.7% (0.0-23.4) versus 8.6% (0.7-21.5) (p=0.98), respectively. However, OCT at the 12-month follow-up showed a significantly lower percentage of uncovered struts [2.6% (0.8-5.6) versus 6.2% (1.7-14.7), (p=0.028), respectively] without significant difference of neointimal thickness. BES showed a greater reduction of percentage Δ of uncovered struts from 3-12 months than that of SES [-17.2±14.5% versus -7.7±16.3%, respectively (p=0.043)].. Both drug-eluting stents showed a high percentage of incomplete strut coverage at 3 months. However, BES showed a significantly lower percentage of uncovered struts at 12 months compared to that of SES. This was achieved by superior strut coverage from 3 to 12 months. Topics: Antineoplastic Agents, Phytogenic; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Paclitaxel; Prospective Studies; Prosthesis Design; Reproducibility of Results; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Tunica Intima | 2013 |
Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus
This study sought to report the final 5 years follow-up of the landmark LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial.. The LEADERS trial is the first randomized study to evaluate biodegradable polymer-based drug-eluting stents (DES) against durable polymer DES.. The LEADERS trial was a 10-center, assessor-blind, noninferiority, "all-comers" trial (N = 1,707). All patients were centrally randomized to treatment with either biodegradable polymer biolimus-eluting stents (BES) (n = 857) or durable polymer sirolimus-eluting stents (SES) (n = 850). The primary endpoint was a composite of cardiac death, myocardial infarction (MI), or clinically indicated target vessel revascularization within 9 months. Secondary endpoints included extending the primary endpoint to 5 years and stent thrombosis (ST) (Academic Research Consortium definition). Analysis was by intention to treat.. At 5 years, the BES was noninferior to SES for the primary endpoint (186 [22.3%] vs. 216 [26.1%], rate ratio [RR]: 0.83 [95% confidence interval (CI): 0.68 to 1.02], p for noninferiority <0.0001, p for superiority = 0.069). The BES was associated with a significant reduction in the more comprehensive patient-orientated composite endpoint of all-cause death, any MI, and all-cause revascularization (297 [35.1%] vs. 339 [40.4%], RR: 0.84 [95% CI: 0.71 to 0.98], p for superiority = 0.023). A significant reduction in very late definite ST from 1 to 5 years was evident with the BES (n = 5 [0.7%] vs. n = 19 [2.5%], RR: 0.26 [95% CI: 0.10 to 0.68], p = 0.003), corresponding to a significant reduction in ST-associated clinical events (primary endpoint) over the same time period (n = 3 of 749 vs. n = 14 of 738, RR: 0.20 [95% CI: 0.06 to 0.71], p = 0.005).. The safety benefit of the biodegradable polymer BES, compared with the durable polymer SES, was related to a significant reduction in very late ST (>1 year) and associated composite clinical outcomes. (Limus Eluted From A Durable Versus ERodable Stent Coating [LEADERS] trial; NCT00389220). Topics: Absorbable Implants; Aged; Cardiovascular Agents; Chi-Square Distribution; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Europe; Female; Humans; Intention to Treat Analysis; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Odds Ratio; Percutaneous Coronary Intervention; Polymers; Proportional Hazards Models; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2013 |
Three-year clinical results of the Axxess Biolimus A9 eluting bifurcation stent system: the DIVERGE study.
To report the three-year clinical outcome of the Axxess™ stent, a nitinol self-expanding Biolimus A9™ eluting stent for treatment of de novo coronary bifurcation lesions. The Axxess stent is a new-generation drug-eluting stent that might offer advantages in terms of improved clinical outcomes and safety profile in bifurcation lesion stenting.. The DIVERGE study was a multicentre, prospective, single-arm trial. The primary endpoint was the cumulative rate of major adverse cardiac events (MACE), a composite of all-cause death, myocardial infarction (MI), and ischaemia-driven target lesion revascularisation (TLR) at one, two and three years. Secondary safety endpoints were cumulative stent thrombosis (ST). A total of 302 patients were included across 14 sites: 77.4% had a true bifurcation lesion, with the left anterior descending/diagonal as target vessel in 80.8%. The Axxess stent was placed in 299 patients (99.0%) and scored as optimal in 93.0%. Two hundred and ninety-eight patients (98.7%) returned for the three-year follow-up. The MACE rate was 9.3% at one year, 14.0% at two years and 16.1% at three years. Individual components at three years were 10.1% for ischaemia-driven TLR, 3.0% for death (2.0% cardiac death), and 7.4% for MI. In the secondary safety endpoint at three years, a total of seven patients (2.3%) had ST with six (2.0%) definite and two (0.7%) probable ST events.. The present large study of the Axxess stent reports a good cumulative MACE rate during three years of long-term follow-up. The Axxess stent offers a promising treatment strategy for bifurcation lesions. Topics: Aged; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Prospective Studies; Sirolimus; Time Factors; Treatment Outcome | 2013 |
Biolimus-eluting biodegradable polymer-coated stent versus durable polymer-coated sirolimus-eluting stent in unselected patients receiving percutaneous coronary intervention (SORT OUT V): a randomised non-inferiority trial.
Third-generation biodegradable polymer drug-eluting stents might reduce the risk of stent thrombosis compared with first-generation permanent polymer drug-eluting stents. We aimed to further investigate the effects of a biodegradable polymer biolimus-eluting stent compared with a durable polymer-coated sirolimus-eluting stent in a population-based setting.. This randomised, multicentre, all-comer, non-inferiority trial was undertaken at three sites across western Denmark. Eligible patients were aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes, and at least one coronary artery lesion (>50% diameter stenosis). We randomly assigned patients (1:1) using an independently managed computer-generated allocation sequence to receive either a biolimus-eluting biodegradable polymer stent (Nobori, Terumo, Tokyo, Japan) or a sirolimus-eluting permanent polymer stent (Cypher Select Plus, Cordis, Johnson & Johnson, Warren, NJ, USA). The primary endpoint was a composite of safety (cardiac death, myocardial infarction, definite stent thrombosis) and efficacy (target vessel revascularisation) at 9 months, analysed by intention to treat (non-inferiority margin of 0·02). This trial is registered with ClinicalTrials.gov, number NCT01254981.. From July, 2009, to January, 2011, we assigned 1229 patients (1532 lesions) to receive the biolimus-eluting stent and 1239 (1555 lesions) to receive the sirolimus-eluting stent. One patient was lost to follow-up because of emigration. Intention-to-treat analysis showed that 50 (4·1%) patients who were assigned the biolimus-eluting stent and 39 (3·1%) who were assigned the sirolimus-eluting stent met the primary endpoint (risk difference 0·9% [upper limit of one-sided 95% CI 2·1%]; p(non-inferiority)=0·06). Significantly more patients in the biolimus-eluting stent group had definite stent thrombosis at 12 months than did those in the sirolimus-eluting stent group (9 [0·7%] vs 2 [0·2%], risk difference 0·6% [95% CI 0·0-1·1]; p=0·034). Per-protocol analysis showed that 45 (3·8%) of 1193 patients who received a biolimus-eluting stent and 39 (3·2%) of 1208 who received a sirolimus-eluting stent met the primary endpoint (risk difference 0·5% [upper limit of one-sided 95% CI 1·8%]; p(non-inferiority)=0·03).. At 1 year follow-up, the biodegradable polymer biolimus-eluting Nobori stent did not improve clinical results compared with a first-generation sirolimus-eluting stent. We will need to obtain long-term data before we can make recommendations for the role of this biolimus-eluting stent in routine clinical practice.. Terumo and Cordis (Johnson & Johnson). Topics: Absorbable Implants; Acute Coronary Syndrome; Aged; Aspirin; Coated Materials, Biocompatible; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Male; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Polymers; Retreatment; Sirolimus | 2013 |
Abluminal biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent (COMPARE II): a randomised, controlled, non-inferiority trial.
Drug-eluting stents with durable biocompatible or biodegradable polymers have been developed to address the risk of thrombosis associated with first-generation drug-eluting stents. We aimed to compare the safety and efficacy of a biodegradable polymer-coated biolimus-eluting stent with a thin-strut everolimus-eluting stent coated with a durable biocompatible polymer.. This open-label, prospective, randomised, controlled, non-inferiority trial was undertaken at 12 sites across Europe. We used limited exclusion criteria (age >18 years, life expectancy >5 years, reference vessel diameter 2·0-4·0 mm) to enrol patients eligible for percutaneous coronary intervention. Patients were randomly allocated (2:1) by computer-generated random numbers to receive either a biodegradable polymer biolimus-eluting stent (Nobori, Terumo, Tokyo, Japan) or a durable fluoropolymer-based everolimus-eluting stent (Xience V or Prime, Abbott Vascular, Santa Clara, CA, USA, or Promus, Boston Scientific, Natick, MA, USA). The primary endpoint was a composite of safety (cardiac death and non-fatal myocardial infarction) and efficacy (clinically indicated target vessel revascularisation) at 12 months, analysed by intention to treat. Patients received dual antiplatelet therapy for 12 months after discharge. The trial is registered with ClinicalTrials.gov, number NCT01233453.. From Jan 12, 2009, to Feb 7, 2011, we enrolled 2707 patients (4025 lesions), 1795 of whom were assigned to receive the biolimus-eluting stent (2638 lesions) and 912 to an everolimus-eluting stent (1387 lesions). 2688 (99·3%) patients completed 12 months' follow-up. Significantly more patients in the biolimus-eluting stent group received a non-assigned stent than did those in the everolimus-eluting stent group (105 [5·9%] vs 19 [2·1%]; p<0·0001). The primary endpoint occurred in 93 (5·2%) patients in the biolimus-eluting stent group and 44 (4·8%) patients in the everolimus-eluting stent group at 12 months (relative risk 1·07 [95% CI 0·75-1·52]; p(non-inferiority)<0·0001). Analysis per protocol did not change the outcome of this trial (p(non-inferiority)<0·0001).. Biodegradable polymer biolimus-eluting stents are as safe and efficacious as the current standard of a thin-strut everolimus-eluting stent with a durable biocompatible polymer. We need to follow-up patients for longer to show whether the biolimus-eluting stent reduces the risk of stent thrombosis after 1 year when compared with the everolimus-eluting stent.. Terumo Europe (Leuven, Belgium) and the Research Foundation of the Cardiology Department, Maasstad Hospital (Rotterdam, Netherlands). Topics: Absorbable Implants; Aspirin; Coated Materials, Biocompatible; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Materials Testing; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Polymers; Prospective Studies; Sirolimus | 2013 |
The pharmacokinetics of Biolimus A9 after elution from the BioMatrix II stent in patients with coronary artery disease: the Stealth PK Study.
This prospective, open-label multicenter study was conducted to assess the pharmacokinetics of Biolimus A9 after elution from BioMatrix II coronary stents. Recent clinical trials have demonstrated the efficacy and safety of Biolimus A9 eluted from different stent platforms. To date, the pharmacokinetics of Biolimus A9 in patients following the deployment of BioMatrix II stents has not yet been studied. BioMatrix II stents were implanted into 27 patients with coronary artery disease. The primary endpoints of the study were the systemic concentrations of Biolimus A9 after 28 days and 6 months as measured using a sensitive validated liquid chromatography-tandem mass spectrometry assay.. The highest measured blood concentration at any time point was 394 pg/mL. At 28 days and 6 months following stent placement, 51.8 and 100% of patients, respectively, had Biolimus A9 concentrations <10 pg/mL. After 9 months, 100% of the patients were free of major cardiac adverse events (MACE). There was no Biolimus A9 toxicity, no cardiac or non-cardiac deaths, no myocardial infarctions, nor target vessel or target lesion revascularizations during the 9 months of follow-up. No case of acute, subacute, or late stent thrombosis was detected.. Compared to other drug-eluting stents, such as Cypher, BioMatrix II results in relatively low systemic exposure, which may be explained by the ablominal coating of the Biomatrix II stent in combination with Biolimus A9's high lipophilicity. Topics: Aged; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Sirolimus; Treatment Outcome | 2011 |
The outcome of bifurcation lesion stenting using a biolimus-eluting stent with a bio-degradable polymer compared to a sirolimus-eluting stent with a durable polymer.
This study investigated the differences in clinical outcomes between patients with bifurcation lesions (BL) treated with a biolimus-eluting stent (BES) with a biodegradable polymer, and a sirolimus-eluting stent (SES) with a durable polymer.. The clinical outcomes were assessed in the 497 patients (BES 258, SES 239) enrolled in the multicentre, randomised LEADERS trial who underwent treatment of ≥1 BL (total=534 BL). At 12-months follow-up there was no significant difference in the primary endpoint of MACE, a composite of cardiac death, myocardial infarction and clinically indicated target vessel revascularisation (BES 12.8% vs. SES 16.3%, p=0.31). Patients treated with BES had comparable rates of cardiac death (BES 2.7% vs. SES 2.9%, p=1.00), numerically higher rates of myocardial infarction (BES 8.9% vs. SES 5.4%, p=0.17), and significantly lower rates of clinically indicated target vessel revascularisation (4.3% vs. 11.3%, p=0.004) when compared to those treated with SES. The rate of stent thrombosis at 12-months was 4.3% and 3.8% for BES and SES, respectively (p=0.82).. In the treatment of BL the use of BES lead to superior efficacy and comparable safety compared to SES. Topics: Absorbable Implants; Acute Coronary Syndrome; Aged; Angioplasty, Balloon, Coronary; Coronary Artery Disease; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Polymers; Sirolimus; Treatment Outcome | 2011 |
2-year clinical follow-up from the randomized comparison of biolimus-eluting stents with biodegradable polymer and sirolimus-eluting stents with durable polymer in routine clinical practice.
This study sought to investigate safety and efficacy of biolimus-eluting stents (BES) with biodegradable polymer as compared with sirolimus-eluting stents (SES) with durable polymer through 2 years of follow-up.. BES with a biodegradable polymer provide similar efficacy and safety as SES with a durable polymer at 9 months. Clinical outcomes beyond the period of biodegradation of the polymer used for drug release and after discontinuation of dual antiplatelet therapy are of particular interest.. A total of 1,707 patients were randomized to unrestricted use of BES (n = 857) or SES (n = 850) in an all-comers patient population.. At 2 years, BES remained noninferior compared with SES for the primary endpoint, which was a composite of cardiac death, myocardial infarction, or clinically indicated target vessel revascularization (BES 12.8% vs. SES 15.2%, hazard ratio [HR]: 0.84, 95% confidence interval [CI]: 0.65 to 1.08, p(noninferiority) < 0.0001, p(superiority) = 0.18). Rates of cardiac death (3.2% vs. 3.9%, HR: 0.81, 95% CI: 0.49 to 1.35, p = 0.42), myocardial infarction (6.3% vs. 5.6%, HR: 1.12, 95% CI: 0.76 to 1.65, p = 0.56), and clinically indicated target vessel revascularization (7.5% vs. 8.6%, HR: 0.86, 95% CI: 0.62 to 1.20, p = 0.38) were similar for BES and SES. The rate of definite stent thrombosis through 2 years was 2.2% for BES and 2.5% for SES (p = 0.73). For the period between 1 and 2 years, event rates for definite stent thrombosis were 0.2% for BES and 0.5% for SES (p = 0.42). After discontinuation of dual antiplatelet therapy, no very late definite stent thrombosis occurred in the BES group.. At 2 years of follow-up, the unrestricted use of BES with a biodegradable polymer maintained a similar safety and efficacy profile as SES with a durable polymer. (Limus Eluted From a Durable Versus Erodable Stent Coating [LEADERS]; NCT00389220). Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chi-Square Distribution; Coronary Angiography; Coronary Artery Disease; Drug Therapy, Combination; Drug-Eluting Stents; Europe; Female; Follow-Up Studies; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Platelet Aggregation Inhibitors; Proportional Hazards Models; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Survival Rate; Thrombosis; Time Factors; Treatment Outcome | 2011 |
Implantation of the biodegradable polymer biolimus-eluting stent in patients with high SYNTAX score is associated with decreased cardiac mortality compared to a permanent polymer sirolimus-eluting stent: two year follow-up results from the "all-comers" LE
The SYNTAX score (SXscore) has been shown to be an effective predictor of clinical outcomes in patients undergoing percutaneous coronary intervention (PCI).. The SXscore was prospectively collected in 1,397 of the 1,707 patients enrolled in the "all-comers" LEADERS trial (patients post-surgical revascularisation were excluded). Post hoc analysis was performed by stratifying clinical outcomes at two-year follow-up, according to one of three SXscore tertiles: SXlow ≤8 (n=464), 8 Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Heart Diseases; Humans; Male; Middle Aged; Polymers; Proportional Hazards Models; Prospective Studies; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Thrombosis; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2011 |
The three year follow-up of the randomised "all-comers" trial of a biodegradable polymer biolimus-eluting stent versus permanent polymer sirolimus-eluting stent (LEADERS).
The current study reports clinical outcomes at three year follow-up of the LEADERS clinical trial which was the first all-comers trial comparing a new generation biodegradable polymer biolimus drug-eluting stent (BES) with the first generation permanent polymer sirolimus-eluting stent (SES).. One thousand seven hundred and seven patients were randomised to unrestricted use of BES (n=857) or SES (n=850) in an all-comers population. Three year follow-up was available in 95% of the patients, 812 treated with BES and 809 treated with SES. At three years, BES remains non-inferior to SES for the primary endpoint of major adverse cardiac events (composite of cardiac death, myocardial infarction (MI), or clinically-indicated target vessel revascularisation (CI-TVR) (BES 15.7% versus SES 19%; HR 0.82 CI 0.65-1.03; p=0.09). The MACE Kaplan Meier event curves increasingly diverge with the difference in events increasing from 1.4% to 2.4% and 3.3% at 1, 2 and 3 years, respectively in favour of BES. The rate of cardiac death was non-significantly lower 4.2% versus 5.2% (HR=0.81 CI 0.52-1.26; p=0.34) and the rate of myocardial infarction was equivalent 7.2% versus 7.1% (HR 1.01 CI 0.70-1.44; p=0.97) for BES versus SES, respectively. Thus BES was non-inferior to SES in all the safety endpoints. Clinically-indicated TVR occurred in 9.4% of BES treated patients versus 11.1% of SES treated patients (HR 0.84 CI 0.62-1.13; p=0.25). Rates of definite stent thrombosis were 2.2% for BES and 2.9% for SES (HR 0.78 CI 0.43-1.43; p=0.43), with the event rate increase of 0.2% from one to three years for BES and 0.9% for SES. For patients presenting with ST-elevation myocardial infarction BES was superior to SES in reducing MACE.. The findings of the three year follow-up support the claim that the biodegradable polymer biolimus-eluting stent has equivalent safety and efficacy to permanent polymer sirolimus-eluting stent in an all-comers patient population. Its performance is superior in some subpopulations such as in ST-elevation MI patients and event rates for BES are overall lower than for SES with a trend toward increasing divergence of outcomes over three years. Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chi-Square Distribution; Coronary Artery Disease; Drug Therapy, Combination; Drug-Eluting Stents; Europe; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Platelet Aggregation Inhibitors; Polymers; Proportional Hazards Models; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2011 |
Long-term clinical outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer sirolimus-eluting stents in patients with coronary artery disease (LEADERS): 4 year follow-up of a randomised non-inferiority trial.
The effectiveness of durable polymer drug-eluting stents comes at the expense of delayed arterial healing and subsequent late adverse events such as stent thrombosis (ST). We report the 4 year follow-up of an assessment of biodegradable polymer-based drug-eluting stents, which aim to improve safety by avoiding the persistent inflammatory stimulus of durable polymers.. We did a multicentre, assessor-masked, non-inferiority trial. Between Nov 27, 2006, and May 18, 2007, patients aged 18 years or older with coronary artery disease were randomly allocated with a computer-generated sequence to receive either biodegradable polymer biolimus-eluting stents (BES) or durable polymer sirolimus-eluting stents (SES; 1:1 ratio). The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation (TVR); patients were followed-up for 4 years. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00389220.. 1707 patients with 2472 lesions were randomly allocated to receive either biodegradable polymer BES (857 patients, 1257 lesions) or durable polymer SES (850 patients, 1215 lesions). At 4 years, biodegradable polymer BES were non-inferior to durable polymer SES for the primary endpoint: 160 (18·7%) patients versus 192 (22·6%) patients (rate ratios [RR] 0·81, 95% CI 0·66-1·00, p for non-inferiority <0·0001, p for superiority=0·050). The RR of definite ST was 0·62 (0·35-1·08, p=0·09), which was largely attributable to a lower risk of very late definite ST between years 1 and 4 in the BES group than in the SES group (RR 0·20, 95% CI 0·06-0·67, p=0·004). Conversely, the RR of definite ST during the first year was 0·99 (0·51-1·95; p=0·98) and the test for interaction between RR of definite ST and time was positive (p(interaction)=0·017). We recorded an interaction with time for events associated with ST but not for other events. For primary endpoint events associated with ST, the RR was 0·86 (0·41-1·80) during the first year and 0·17 (0·04-0·78) during subsequent years (p(interaction)=0·049).. Biodegradable polymer BES are non-inferior to durable polymer SES and, by reducing the risk of cardiac events associated with very late ST, might improve long-term clinical outcomes for up to 4 years compared with durable polymer SES.. Biosensors Europe SA, Switzerland. Topics: Absorbable Implants; Coronary Artery Disease; Drug-Eluting Stents; Follow-Up Studies; Humans; Polymers; Sirolimus; Thrombosis | 2011 |
The pharmacokinetics of Biolimus A9 after elution from the Nobori stent in patients with coronary artery disease: the NOBORI PK study.
The aim of this study was to assess the pharmacokinetics and tolerability of Biolimus A9 eluted from Nobori coronary stents.. : The release kinetics and pharmacokinetics of drugs delivered via coronary stents have been shown to play an essential role in the efficacy and safety of drug eluting stents.. Twenty patients with coronary artery disease were treated with single 14-mm (10 patients) or 28-mm long stent (10 patients). Blood samples were drawn at 16 time points to determine the pharmacokinetics of Biolimus A9. At seven time points, complete laboratory and toxicology panels were assessed to screen for potential Biolimus A9 toxicity. The primary endpoint of the study was the systemic blood concentrations of Biolimus A9 after 28 days and 6 months as measured using highly specific and sensitive liquid chromatography- tandem mass spectrometry assay.. At 28 days, 6 patients (30%) had quantifiable Biolimus A9 concentrations in blood. The highest Biolimus A9 blood concentration measured in any sample was 32.2 pg/mL. The median time to maximum concentration was 2 hr, ranging from 0.05 hr to 3 months. Six months after stent implantation, only 1 of 20 patients had measurable Biolimus A9 concentrations at the lowest level of quantification, while at 9 months no sample had quantifiable Biolimus A9 concentrations. Laboratory and toxicology assessments did not indicate any impact of Biolimus A9 on the evaluated parameters.. Results of this study suggest that systemic exposure to Biolimus A9 was very low and that Biolimus A9 was well tolerated. Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chromatography, Liquid; Colorado; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Prospective Studies; Prosthesis Design; Serbia; Sirolimus; Tandem Mass Spectrometry; Treatment Outcome | 2008 |
Novel drug eluting stent system for customised treatment of coronary lesions: CUSTOM I feasibility trial 24 month results.
The Custom NX 36 Drug Eluting Stent (DES) System is designed to treat coronary lesions via in situ stent length customisation. The stent evaluated in this study consists of nine interdigitated stent segments, each 4 mm in length, coated with a biodegradable formulation of Biolimus A9 and Poly-Lactic-Acid, a biodegradable drug carrier, and loaded into a unique sheath protected, integrated balloon delivery system.. The objective of this non-randomised prospective multicentre CUSTOM I Trial was to demonstrate the safety of in situ stent length customisation in 30 consecutive patients. Angiographic (QCA) and intravascular ultrasound (IVUS) follow-up was performed at two cohort time intervals: four (n=10) or eight (n=20) months. Mean lesion length and reference vessel diameters were 17.7 +/- 9.6 mm and 2.6 +/- 0.3 mm, respectively. Procedural success was 93%. There were three MACEs in the study population from enrollment through to twenty-four month follow-up. The in-hospital MACE rate was 2/30, with non-Q-wave myocardial infarctions events in two patients who recovered without further sequelae. At five months, one patient who had crossed over initially to PTCA required CABG surgery. Results from QCA and IVUS assessments at four and eight months showed no binary restenosis, mean in-stent late luminal loss of 0.25 +/- 0.23 mm and 0.26 +/- 0.23 mm.. This first evaluation of the new customisable Biolimus A9-eluting Custom NX stent suggests safety and efficacy through twenty-four month follow-up. Further evaluations are warranted to confirm the overall favourable outcomes. Topics: Aged; Angioplasty, Balloon, Coronary; Coated Materials, Biocompatible; Coronary Artery Disease; Drug Delivery Systems; Drug-Eluting Stents; Feasibility Studies; Female; Follow-Up Studies; Humans; Lactic Acid; Male; Middle Aged; Polyesters; Polymers; Prospective Studies; Sirolimus; Treatment Outcome | 2008 |
Analysis of bifurcation lesions treated with novel drug-eluting dedicated bifurcation stent system: intravascular ultrasound results of the AXXESS PLUS trial.
The aim of this intravascular ultrasound (IVUS) study was to assess the efficacy of the AXXESS Plus stent system for the treatment of bifurcation coronary lesions.. The AXXESS Plus is a novel bifurcation drug-eluting stent, comprised of a self-expanding flare-shaped stent platform and bioabsorbable polymer coating that releases Biolimus A9.. Data were obtained from the AXXESS PLUS trial, a prospective, multicenter, nonrandomized, single-arm study to evaluate safety and efficacy. Six-month follow-up IVUS analysis was available in 49 cases. Volumetric analysis using Simpson's method within the AXXESS stent, and cross-sectional analysis at the ostium of main branch and/or side branch was performed. Impact of bifurcation angle on stent expansion at the carina was also evaluated.. Within the AXXESS stent, neointimal volume obstruction percentage was 2.3% +/- 2.2%, with a minimum lumen area of 7.9 +/- 2.6 mm(2). Lumen area was 5.2 +/- 1.7 mm(2) at main branch ostium, and 4.0 +/- 1.5 mm(2) at side branch ostium. In two cases, incomplete stent apposition was observed at the proximal edge of the AXXESS stent. In one case, a gap between the AXXESS stent and an additional stent was observed. Greater bifurcation angle inversely correlated with smaller stent area at side branch ostium (r = -0.54, P = 0.03) but not at main branch ostium (r = -0.2, P = 0.29).. This novel self-expanding, drug-eluting bifurcation stent demonstrated effective lesion coverage along with significant neointimal suppression equivalent to current generation balloon-expandable drug-eluting stent technology. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Hyperplasia; Male; Middle Aged; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome; Tunica Intima; Ultrasonography, Interventional | 2007 |
49 other study(ies) available for umirolimus and Coronary-Artery-Disease
Article | Year |
---|---|
Vascular healing in high-bleeding-risk patients at 3-month after everolimus-eluting stent versus biolimus A9-coated stent implantation: insights from analysis of optical coherence tomography and coronary angioscopy.
The prevalence of high-bleeding-risk (HBR) patients who undergo coronary stenting has been reported as 20-40%. This study sought to assess vascular healing in HBR patients by coronary angioscopy (CAS) and optical coherence tomography (OCT). We prospectively analyzed 38 HBR patients with coronary artery disease who successfully underwent everolimus-eluting stent (EES) implantation (20 patients, 23 lesions) or drug-coated stent (DCS) implantation (18 patients, 18 lesions). Follow-up coronary angiography, CAS, and OCT were planned at 3 months after the procedure. The clinical characteristics and inclusion criteria of HBR were comparable between groups. CAS analysis showed that mean yellow color grade was significantly higher with EES than with DCS (1.33 [1.0, 1.67] vs. 1.0 [0.67, 1.5]; P = 0.04). In contrast, OCT analysis demonstrated that most struts in both groups were well-apposed struts with neointimal coverage (93.9% each; P = 1.00), and percentages of the mean neointimal area were comparable between EES and DCS (4.4 ± 3.5 mm Topics: Angioscopy; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Everolimus; Hemorrhage; Humans; Percutaneous Coronary Intervention; Tomography, Optical Coherence; Treatment Outcome | 2023 |
Comparison of 1-Month and 12-Month Vessel Responses Between the Polymer-Free Biolimus A9-Coated Stent and the Durable Polymer Everolimus-Eluting Stent.
A polymer-free biolimus A9-coated stent (PF-BCS) may achieve better arterial healing than a durable polymer drug-eluting stent owing to its polymer-free feature.Methods and Results: This multicenter, prospective, observational study enrolled 105 patients (132 lesions) who underwent PF-BCS (51 patients, 71 lesions) or durable polymer everolimus-eluting stent (DP-EES, 54 patients, 61 lesions) implantation. Serial coronary angioscopy (CAS) and optical coherence tomography (OCT) examinations were performed at 1 and 12 months, and the serial vessel responses were compared between PF-BCS and DP-EES. The primary outcome measure was the incidence of subclinical intrastent thrombus on CAS. The secondary outcome measures were: adequate strut coverage (≥40 μm) on OCT and maximum yellow color grade on CAS. The incidence of thrombus was high at 1 month (100% vs. 93%, P=0.091), but decreased at 12 months (18% vs. 25%, P=0.56), without a significant difference between PF-BCS and DP-EES. The adequate strut coverage rate was significantly higher (84±14% vs. 69±22%, P<0.001) and yellow color was significantly less intense (P=0.012) at 12 months in PF-BCS than in DP-EES; however, they were not significantly different at 1 month (adequate strut coverage: 47±21% vs. 50±17%, P=0.40; yellow color: P=0.99).. Although the thrombogenicity of PF-BCS was similar to that of DP-EES, the adequate coverage and plaque stabilization rates of PF-BCS were superior to those of DP-EES at 12 months. Topics: Absorbable Implants; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Humans; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Prosthesis Design; Sirolimus; Thrombosis; Treatment Outcome | 2022 |
Real-world analysis of a Biolimus A9 polymer-free drug-coated stent with very short dual antiplatelet therapy in patients at high bleeding risk.
Patients at high risk of bleeding requiring percutaneous coronary intervention (PCI) need careful evaluation of both their thrombotic and their bleeding risks. In these patients, a polymer-free metallic stent coated with biolimus-A9 (BA9-DCS) followed by 1‑month dual antiplatelet therapy (DAPT) could be a safe option; however, real-world data are still lacking. We analyzed the performance of the device in a real-world scenario.. Patients assessed as being at high risk of bleeding with an indication for PCI were treated with BA9-DCS and DAPT consisting of aspirin (100 mg/day) and clopidogrel (75 mg/day) for at least 1 month, followed by either oral anticoagulation or single antiplatelet therapy. No exclusion criteria were used. The primary endpoint was the occurrence of an adverse event after PCI, i.e. severe bleeding requiring hospitalization, ischemic or hemorrhagic stroke, clinically driven stent thrombosis, myocardial infarction or cardiac death.. Overall, 89 patients were enrolled in this study [median age 75 (66-81) years; 27 females (30%)] and 171 interventions were performed. During a median follow-up of 203 (145-273) days the primary endpoint occurred in 20 patients (23%): 12 (13%) had clinically significant bleeding, four (5%) ischemic stroke and four (5%) died from cardiac causes related neither to stent thrombosis nor to acute myocardial infarction. Female gender emerged as the only statistically significant predictor of an adverse event (adjusted hazard ratio (HR) 3.3; 95% confidence interval (CI): 1.2-8.7, p = 0.017).. In real-world patients at high risk of bleeding, implantation of the polymer-free metallic stent coated with Biolimus-A9 (Biofreedom®; Biosensors Europe, Morges, Switzerland) followed by 1 -month DAPT showed encouraging results without any stent thrombosis.. HINTERGRUND: Patienten mit hohem Blutungsrisiko, bei denen eine perkutane Koronarintervention (PCI) notwendig ist, müssen sorgfältig bezüglich ihres Thrombose- wie auch Blutungsrisikos beurteilt werden. Bei ihnen könnte der Einsatz eines mit Biolimus A9 beschichteten polymerfreien Metallstents (BA9-DCS) mit nachfolgender 1‑monatiger dualer Plättchenhemmung („dual antiplatelet therapy“ [DAPT]) eine sichere Option sein. Es fehlen allerdings immer noch Daten aus der Praxis. Daher haben wir den BA9-DCS unter Realbedingungen untersucht.. Patienten mit hohem Blutungsrisiko und Indikation zur PCI wurden mit BA9-DCS und einer DAPT (Acetylsalicylsäure 100 mg/Tag und Clopidogrel 75 mg/Tag für mindestens 1 Monat) behandelt, worauf eine orale Antikoagulation oder einfache Plättchenhemmung folgte. Ausschlusskriterien gab es nicht. Als primärer Endpunkt wurde der Eintritt eines unerwünschten Ereignisses nach PCI definiert (schwere Blutung mit erforderlicher Krankenhausaufnahme, ischämischer oder hämorrhagischer Schlaganfall, klinisch begünstigte Stentthrombose, Myokardinfarkt oder kardial bedingter Tod).. Insgesamt 89 Patienten wurden in die Studie eingeschlossen (medianes Alter 75 [66–81] Jahre; 27 weiblich [30 %]); es wurden 171 Interventionen durchgeführt. In einem medianen Follow-up von 203 (145–273) Tagen wurde der primäre Endpunkt bei 20 Patienten (23 %) erreicht: 12 (13 %) hatten eine klinisch relevante Blutung, 4 (5 %) einen ischämischen Schlaganfall und 4 (5 %) verstarben kardial bedingt, wobei die Ursache weder mit einer Stentthrombose noch mit einem akuten Myokardinfarkt zusammenhing. Weibliches Geschlecht erwies sich als einziger statistisch signifikanter Prädiktor für ein unerwünschtes Ereignis (adjustierte Hazard Ratio [HR] 3,3; 95 %-Konfidenzintervall [KI]: 1,2–8,7, p = 0,017).. Bei Patienten unter Realbedingungen mit hohem Blutungsrisiko lieferte die Implantation des mit Biolimus A9 beschichteten polymerfreien Metallstents (Biofreedom®, Biosensors Europe, Morges, Schweiz) gefolgt von einer 1‑monatigen DAPT vielversprechende Ergebnisse, ohne dass es zu einer Stentthrombose kam. Topics: Aged; Coronary Artery Disease; Drug Therapy, Combination; Drug-Eluting Stents; Europe; Female; Humans; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Polymers; Sirolimus; Switzerland; Treatment Outcome | 2021 |
The Biolimus A9-coated BioFreedom
In this state-of-the-art review, we present the findings and a critical analysis of the Leaders Free trial program, evaluating outcomes of a new stent-generation based on polymer-free technology, in this case the BioFreedom Topics: Coronary Artery Disease; Drug-Eluting Stents; Humans; Percutaneous Coronary Intervention; Prosthesis Design; Sirolimus; Stents; Treatment Outcome | 2021 |
One-year performance of thin-strut cobalt chromium sirolimus-eluting stent versus thicker strut stainless steel biolimus-eluting coronary stent: a propensity-matched analysis of two international all-comers registries.
Recent improvements in coronary stent design have focussed on thinner struts, different alloys and architecture, more biocompatible polymers, and shorter drug absorption times. This study evaluates safety and efficacy of a newer generation thin-strut cobalt chromium sirolimus-eluting coronary stent (SES, Ultimaster) in comparison with a second-generation thicker strut stainless steel biolimus-eluting stent (BES, Nobori) in percutaneous coronary intervention (PCI) practice.. A propensity score analysis was performed to adjust for differences in baseline characteristics of 8137 SES patients and 2738 BES patients of two PCI registries (e-Ultimaster and NOBORI 2). An independent clinical event committee adjudicated all endpoint-related adverse events.. The use of SES, as compared with BES was associated with a significantly lower rate of myocardial infarction (MI) (1.2% vs 2.2%; P = 0.0006) and target vessel-related MI (1.1% vs 1.8%; P = 0.002) at 1 year. One-year composite endpoints of all predefined endpoints were lower in patients undergoing SES implantation (target lesion failure: 3.2% vs 4.1%; P = 0.03, target vessel failure: 3.7% vs 5.0%; P = 0.003, patient-oriented composite endpoint 5.7% vs 6.8%; P = 0.03). No significant differences between SES and BES were observed in all-cause death (2.0% vs 1.6%; P = 0.19), cardiac death (1.2% vs 1.2%; P = 0.76) or stent thrombosis (0.6% vs 0.8%; P = 0.43).. These findings suggest an improved clinical safety and efficacy of a newer generation thin-strut SES as compared with a second-generation thicker strut BES. Topics: Aged; Biocompatible Materials; Chromium Alloys; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Equipment Failure Analysis; Female; Humans; Immunosuppressive Agents; Male; Percutaneous Coronary Intervention; Postoperative Complications; Prosthesis Design; Registries; Sirolimus; Survival Analysis | 2021 |
Angioscopic assessments and clinical outcomes one year after polymer-free biolimus A9-coated coronary stent implantation.
Polymer-free biolimus A9-coated coronary stent (DCS) has novel features which lead to the expectation of better arterial healing. However, comparisons of intravascular status between DCS and drug-eluting stents (DES), and robust real-word clinical assessments of DCS have been lacking to date.. From September 2017 to September 2018, we evaluated the intra-vascular status of 74 DCS implanted in 55 lesions from 43 patients using coronary angioscopy (CAS) approximately one year after implantation from a cohort of 219 lesions in 158 patients. We set 239 second-generation durable-polymer DES (DP-DES) implanted in 211 lesions from 180 patients from a cohort of 2652 lesions in 1914 patients as the control. Angioscopic images were analyzed to determine (1) the dominant degree of neointimal coverage (NIC) over the stent; (2) the heterogeneity of NIC; (3) yellow color grade of the stented segment; and (4) the presence of intra-stent thrombus. The primary outcome was the incidence of thrombus and secondary outcomes were the other CAS findings, and the 1-year clinical outcomes which included target lesion revascularization (TLR) and major adverse cardiac events (MACE). To minimize inter-group differences in baseline characteristics, propensity score matching was performed for clinical outcomes.. Incidence of thrombus adhesion was similar in DCS and DP-DES groups (28.4% versus 22.6%, p=0.31). However, the dominant NIC grade was significantly higher in DCS (p<0.001), while NIC was more heterogeneous in DCS than in DP-DES (p=0.001). Maximum yellow color grade was similar (p=0.22). After propensity score matching, 202 lesion pairs from 146 patient pairs were retained for analysis. The cumulative incidence of TLR (4.6% versus 3.8%, p=0.38) and MACE (11.6% versus 11.7%, p=0.84) was similar for DCS and DP-DES.. DCS showed thrombus adhesion and clinical outcomes at 1 year similar to DP-DES. DCS can thus be used with similar safety and efficacy as DP-DES. Topics: Absorbable Implants; Angioscopy; Coronary Artery Disease; Drug-Eluting Stents; Humans; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Sirolimus; Stents; Treatment Outcome | 2021 |
Thin Strut CoCr Biodegradable Polymer Biolimus A9-Eluting Stents versus Thicker Strut Stainless Steel Biodegradable Polymer Biolimus A9-Eluting Stents: Two-Year Clinical Outcomes.
While thinner struts are associated with improved clinical outcomes in bare-metal stents (BMS), reducing strut thickness may affect drug delivery from drug-eluting stents (DES) and there are limited data comparing otherwise similar thin and thick strut DES. We assessed 2-year outcomes of patients treated with a thin strut (84-88um) cobalt-chromium, biodegradable polymer, Biolimus A9-eluting stent (CoCr-BP-BES) and compared these to patients treated with a stainless steel, biodegradable polymer, Biolimus A9-eluting stent (SS-BP-BES).. In total, 1257 patients were studied: 400 patients from 12 centres receiving ≥1 CoCr-BP-BES in the prospective Biomatrix Alpha registry underwent prespecified comparison with 857 patients who received ≥1 Biomatrix Flex SS-BP-BES in the LEADERS study (historical control). The primary outcome was major adverse cardiac events (MACE)-cardiac death, myocardial infarction (MI), or clinically driven target vessel revascularization (cd-TVR). Propensity analysis was used to adjust for differences in baseline variables and a landmark analysis at day-3 to account for differences in periprocedural MI definitions.. At 2-year follow-up, propensity-adjusted analysis showed the thin strut (84-88um) Biomatrix Alpha CoCr-BP-BES was associated with improved clinical outcomes compared with the thicker strut (114-120um) Biomatrix Flex SS-BP-BES. Topics: Absorbable Implants; Acute Coronary Syndrome; Aged; Anti-Inflammatory Agents; Chromium Alloys; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Registries; Sirolimus; Stainless Steel; Treatment Outcome | 2021 |
Real-world reasons and outcomes for 1-month versus longer dual antiplatelet therapy strategies with a polymer-free BIOLIMUS A9-coated stent.
A large trial established the favorable profile of a new polymer-free biolimus A9-eluting stent (PF-BES) with a 1-month dual antiplatelet therapy (DAPT) in high bleeding risk (HBR) patients. This is the first study comparing outcomes for a 1-month versus longer DAPT strategies following PF-BES-percutaneous coronary intervention (PCI).. All patients undergoing PF-BES-PCI (January 2016 to July 2018) were included in the multicenter CHANCE registry. Patients were stratified according to DAPT strategy at discharge (planned 1-month vs. planned >1-month). Primary outcomes were the 390-day estimates of a patient-oriented and of a device-oriented composite endpoints (POCE: death, myocardial infarction [MI] or target vessel revascularization; DOCE: cardiac death, target vessel-MI or ischemia-driven target lesion revascularization). Landmark analyses from 1-month post-PCI were carried.. Following PF-BES-PCI, 328(40.3%) and 485(59.6%) patients were discharged with 1-month and longer DAPT (12 months [6-12]), respectively. Patients with a previous or index MI were less likely to be discharged on 1-month DAPT. Patients prescribed with 1-month DAPT were more likely to be at HBR than those with longer DAPT (90.2% vs. 69.9%, p = .001). No between-groups differences in the primary outcomes (planned 1-month vs. planned >1-month DAPT: POCE 11.9% vs. 13.2%, p = .747; DOCE: 4.8% vs. 8.1%, p = .500) were observed, also after adjusting for confoundings (POCE: adjusted-hazard ratio [adj-HR] 1.26, 95%CI 0.74-2.13; DOCE: adj-HR 1.00, 95%CI 0.49-1.99). Landmark analyses showed similar results.. In a large all-comers registry of PF-BES PCI, no interaction of planned DAPT strategy (1-month vs. >1-month) with outcomes was found. This observation warrants investigation in adequately powered randomized studies (ClinicalTrials.gov NCT03622203). Topics: Aged; Aged, 80 and over; Cardiovascular Agents; Coronary Artery Disease; Drug Administration Schedule; Drug-Eluting Stents; Dual Anti-Platelet Therapy; Female; Humans; Italy; Male; Middle Aged; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Prosthesis Design; Registries; Sirolimus; Time Factors; Treatment Outcome | 2020 |
Dual antiplatelet therapy strategies and clinical outcomes in patients treated with polymer-free biolimus A9-coated stents.
A large trial established the favourable clinical profile of a new polymer-free biolimus A9-eluting stent (PF-BES) with a one-month dual antiplatelet therapy (DAPT) regimen in patients at high bleeding risk (HBR). We aimed to evaluate the real-world patterns of indications, DAPT strategies and outcomes for the PF-BES following this evidence.. CHANCE is a multicentre registry including all patients who underwent percutaneous coronary intervention (PCI) with at least one PF-BES. The reasons for the PF-BES PCI and planned antithrombotic regimens were collected. Primary outcomes were the 390-day Kaplan-Meier estimates of patient-oriented and device-oriented composite endpoints (POCE: death, myocardial infarction [MI] or target vessel revascularisation [TVR]; DOCE: cardiac death, target vessel MI or ischaemia-driven target lesion revascularisation [ID-TLR]). Between January 2016 and July 2018, 858 patients (age 74±10 years, 64.6% male, 58.7% acute coronary syndrome presentation) underwent PF-BES PCI. The main reasons for the physicians' choice of PF-BES reflected a perceived HBR in 77.7% of patients. One-month DAPT was planned in 40.3% of patients. At 390-day follow-up (median 340 days, interquartile range: 187-390 days), the estimated incidence of POCE was 13.1% (any MI 3.7%, any TVR 3.4%) and of DOCE was 7.1% (TV-MI 3.6%, ID-TLR 1.4%), while the 390-day estimate of any bleeding event was 11.1% (BARC 3-5 bleeding 3.0%).. In a large all-comers registry, PF-BES was used mostly in HBR patients, frequently followed by a very short DAPT regimen. The reported outcomes suggest a favourable safety and efficacy profile for the PF-BES in a real-world clinical setting. ClinicalTrials.gov identifier: NCT03622203. Topics: Aged; Aged, 80 and over; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Polymers; Sirolimus; Treatment Outcome | 2020 |
Safety and efficacy of polymer-free biolimus-eluting stents versus ultrathin stents in unprotected left main or coronary bifurcation: A propensity score analysis from the RAIN and CHANCE registries.
Evaluate safety and efficacy of polymer-free biolimus-eluting stents (PF-BESs) versus ultrathin stents in unprotected left main (ULM) or bifurcation.. PF-BESs due to reduced length of dual antiplatelet therapy (DAPT) are increasingly used. However, there are limited data about safety and efficacy for ULM or bifurcation.. We selected all-patients treated for ULM or bifurcation from two multicenter real life registries (RAIN [NCT03544294] evaluating ultrathin stents, CHANCE [NCT03622203] appraising PF-BES). After propensity score with matching, the primary endpoint was major adverse cardiac events (MACE; a composite of all-cause death, myocardial infarction, target lesion revascularization [TLR], and stent thrombosis [ST]), while its components along with target vessel revascularization (TVR) secondary endpoints.. Three thousand and three patients treated with ultrathin stents and 446 with PF-BESs, resulting respectively in 562 and 281 after propensity score with matching (33 and 22%, respectively, with ULM disease). After 12 (8-20) months, rates of MACE were similar (9 vs. 8%, p = 0.56) without difference in TLR and ST (3.0 vs. 1.7%, p = .19 and 1.8 vs. 1.1%, p = .42). These results were consistent for ULM group (3 vs. 1.7% and 1.8 vs. 1.1%, p = .49 and .76), for non-ULM group (2.1 vs. 3.4%, p = .56 and 1.2 vs. 1.7%, p = .78) and for two-stent strategy (8.7 vs. 4.5% and 4.3 vs. 3.2%, p = .75 and .91). Among patients treated with 1 month of DAPT in both groups, those with ultrathin stents experienced higher rates of MACE related to all-cause death (22 vs. 12%, p = .04) with higher although not significant rates of ST (3 vs. 0%, p = .45).. PF-BES implanted on ULM or BiF offered freedom from TLR and ST comparable to ultrathin stents. PF-BESs patients assuming DAPT for 1 month experienced a lower despite not significant incidence of ST. Topics: Aged; Aged, 80 and over; Cardiovascular Agents; Clinical Protocols; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Propensity Score; Prosthesis Design; Registries; Retrospective Studies; Risk Assessment; Risk Factors; Sirolimus; Time Factors | 2020 |
Impact of Insulin-Treated and Noninsulin-Treated Diabetes Mellitus in All-Comer Patients Undergoing Percutaneous Coronary Interventions With Polymer-Free Biolimus-Eluting Stent (from the RUDI-FREE Registry).
Patients with diabetes mellitus (DM) have worse outcomes after percutaneous coronary intervention (PCI). Recent evidences suggest a differential impact of insulin-treated and noninsulin-treated DM on prognosis. We evaluated the clinical outcome of diabetic patients after PCI with polymer-free biolimus-eluting stent from the RUDI-FREE Registry, investigating a possible different prognostic impact of insulin-treated and noninsulin-treated DM. A total of 1,104 consecutive patients who underwent PCI with polymer-free biolimus-eluting stent, enrolled in the RUDI-FREE observational, multicenter, single-arm registry, were stratified by diabetic status; diabetic population was further divided on the basis of insulin treatment. Primary end points of the study were target lesion failure (TLF; composite of cardiac death, target vessel myocardial infarction, target lesion revascularization) and major adverse cardiac and cerebrovascular events (composite of cardiac death, stroke, and myocardial infarction). Multiple ischemic adverse events were also single-handedly considered as secondary end points. At 1 year, TLF was significantly higher in the diabetic cohort, as compared with nondiabetic patients (6.0% vs 3.1%, p 0.022). None of the end points resulted significantly different between nondiabetics and noninsulin-treated diabetic patients. Divergently, compared with nondiabetic, insulin-treated diabetic patients faced significant higher rates of TLF (10.8% vs 3.1%, p 0.003), major adverse cardiac and cerebrovascular events (10.8% vs 3.4%, p 0.004), and of most of the analyzed adverse events. In conclusion, patients with DM had a higher risk of TLF compared with nondiabetics; nonetheless, the worse outcome of the diabetic population seems to be driven by the insulin-treated diabetic subpopulation. This finding suggests a different risk profile of insulin-treated and noninsulin-treated diabetic patients in the modern era of PCI. Topics: Aged; Coronary Angiography; Coronary Artery Disease; Diabetes Mellitus; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Hypoglycemic Agents; Immunosuppressive Agents; Insulin; Male; Percutaneous Coronary Intervention; Polymers; Prognosis; Prospective Studies; Prosthesis Design; Registries; Sirolimus | 2019 |
Application of the MADS classification system in a "mega mammoth" stent trial: Feasibility and preliminary clinical implications.
We attempted to test the feasibility of application of the MADS classification system in the largest stent trial to date and evaluate the preliminary clinical implications of this approach.. In the randomized GLOBAL LEADERS trial, testing two different antiplatelet strategies in patients undergoing PCI with bivalirudin and biolimus-eluting stents, the e-CRF was dedicated to bifurcation treatment according to the MADS classification. Based on this e-CRF, the techniques used for bifurcations treatment in GLOBAL LEADERS were described and compared with two large, all-comer registries of bifurcations treatment (I-BIGIS and COBIS), used as historical controls.. Among 15,991 patients enrolled in the trial, 22,921 lesions treated at the index and staged procedure were available for analysis and 2,757 of these lesions were bifurcations and 7 were trifurcation lesions. The e-CRF-based MADS classification was achieved in 2,757 of these lesions (100%). 80.3% of bifurcations were treated using a single stent, 18.9% using 2 stents and 0.7% using 3 stents. Overall, the "main across side first" approach (A) was used in 77.4% with the "side branch first" approach (S) being the second most frequently used technique (10.2%). A single stent was used in the majority of the "A" approach (87.9%). A reduction in the use of 2-stent techniques (from 33.9 to 18.9%) was observed between GLOBAL LEADERS and I-BIGIS. The "A" approach was the most frequently used technique in GLOBAL LEADERS, while in COBIS the "S" strategy was most frequently employed.. Application of the MADS classification through an e-CRF was feasible in the largest stent trial today and provided useful information about the trends observed overtime in the treatment of bifurcation lesions. Topics: Antithrombins; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Drug-Eluting Stents; Feasibility Studies; Hirudins; Humans; Peptide Fragments; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Predictive Value of Tests; Prosthesis Design; Randomized Controlled Trials as Topic; Recombinant Proteins; Sirolimus; Terminology as Topic; Treatment Outcome | 2019 |
Safety and Efficacy of Polymer-Free Drug-Eluting Stents.
Background Polymer-free drug-eluting stents are based on different technologies for drug binding and release without the use of polymer coatings. It is unknown whether different polymer-free drug-eluting stents are comparable in terms of safety and efficacy profiles. Methods and Results Polymer-free BioFreedom biolimus-eluting stents (BES) and polymer-free Cre8 amphilimus-eluting stents (AES) were investigated in 2 recent multicenter registries including 2320 all-comer patients undergoing percutaneous coronary interventions at 22 Italian centers. Using propensity score matching, safety and efficacy outcomes were compared among 1280 patients (640 matched pairs) treated with BioFreedom BES or Cre8 AES. The primary end point was target lesion failure-a composite of cardiac death, target vessel myocardial infarction, and target lesion revascularization (TLR). At 1 year, target lesion failure occurred in 4.0% of BES and 4.2% of AES-treated patients (hazard ratio [HR] 0.98, 95% CI, 0.57-1.70). Risks of cardiac death (2.0% versus 2.1%; HR, 1.03; 95% CI, 0.47-2.26), target vessel myocardial infarction (0.8% versus 0.3%; HR, 1.89; 95% CI, 0.50-6.80), TLR (1.5% versus 2.2%; HR, 0.74; 95% CI, 0.34-1.62), and definite/probable stent thrombosis (0.9% versus 0.8%; HR, 1.17; 95% CI, 0.36-3.81) were comparable in patients treated with BioFreedom BES and Cre8 AES. A differential treatment effect by diabetes mellitus status was observed, indicating a benefit of AES in patients with diabetes mellitus ( P interaction=0.003). Conclusions The present study shows that BioFreedom BES and Cre8 AES have favorable and comparable safety and efficacy profiles in all-comer patients undergoing percutaneous coronary intervention. Further evaluation in large-scale, randomized trials are necessary to confirm our findings. Topics: Aged; Coronary Artery Disease; Coronary Stenosis; Drug-Eluting Stents; Female; Humans; Italy; Male; Middle Aged; Observational Studies as Topic; Percutaneous Coronary Intervention; Prosthesis Design; Registries; Risk Assessment; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2019 |
One-year clinical outcomes between biodegradable-polymer-coated biolimus-eluting stent and durable-polymer-coated drug-eluting stents in STEMI patients with multivessel coronary artery disease undergoing culprit-only or multivessel PCI.
There are limited data comparing clinical outcomes among new-generation drug-eluting stents (DES) in ST-segment elevation myocardial infarction (STEMI) patients with multivessel coronary artery disease (MVD) who underwent primary percutaneous coronary intervention (PCI) with culprit-only or multivessel PCI. We investigated 1-year clinical outcomes between biodegradable-polymer (BP)-coated biolimus-eluting stent (BES) and durable-polymer (DP)-coated DES in STEMI patients with MVD who underwent two different reperfusion strategies.. A total of 4255 patients were enrolled and divided into two groups, a culprit-only (n = 2571, BP- [n = 264] or DP-DES [n = 2307]) or a multivessel PCI group (n = 1684, BP- [n = 145] or DP-DES [n = 1539]). The primary endpoint was major adverse cardiac events (MACE) defined as all-cause death, recurrent myocardial infarction (re-MI), and total repeat revascularization. The secondary endpoint was the incidence of definite or probable stent thrombosis (ST).. BP-BES and DP-DES showed a similar 1-year adjusted hazard ratio (HR) for MACE (culprit-only, adjusted hazard ratio [HR], 1.114; p = 0.740; multivessel, HR, 0.564; p = 0.167) and ST (culprit-only, HR, 1.110, p = 0.891; multivessel, HR, 0.375; p = 0.402). The adjusted HR for all-cause death, re-MI, and repeat revascularization were similar between the two groups. In the total population, the culprit-only PCI group showed a higher incidence of total repeat revascularization than the multivessel PCI group.. BP-BES and DP-DES showed comparable safety and efficacy in STEMI patients with MVD who underwent primary PCI with two different reperfusion strategies during a 1-year follow-up period. Topics: Aged; Coated Materials, Biocompatible; Cohort Studies; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Retrospective Studies; Sirolimus; ST Elevation Myocardial Infarction; Time Factors; Treatment Outcome | 2019 |
Impact of Diabetes on Clinical Outcomes After Polymer-Free Amphilimus- and Biolimus-Eluting Stent Implantation.
Topics: Cardiovascular Agents; Coronary Artery Disease; Diabetes Mellitus; Drug-Eluting Stents; Humans; Italy; Percutaneous Coronary Intervention; Prosthesis Design; Registries; Risk Assessment; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2019 |
Efficacy of biolimus A9-eluting stent for treatment of right coronary ostial lesion with intravascular ultrasound guidance: a multi-center registry.
The aim of this study was to assess the efficacy of a biolimus A9-eluting stent in patients with a right coronary artery (RCA) ostial lesion. Ostial lesions of the RCA have been a limitation of percutaneous coronary intervention even in the drug-eluting stent (DES) era. However, clinical outcomes after the deployment of a second generation DES to an RCA ostial lesion with intravascular ultrasound (IVUS) guidance have not been fully elucidated. From September 2011 to March 2013, 74 patients were enrolled in 17 centers from Japan. RCA ostial lesion was defined as de novo significant stenotic lesion located within 15 mm from ostium. IVUS was used for all cases to confirm the location of ostium and evaluate stent coverage of ostium. Patients with hemodialysis were excluded. The primary endpoint is a major adverse cardiac event (MACE) at 1 year. Forty two percent of patients had multi-vessel disease. Angiographically severe calcification was observed in 26% of the lesions. The mean stent diameter was 3.3 ± 0.3 mm (3.5 mm, 72%, 3.0 mm, 25%, and 2.75 and 2.5 mm, 3%), stent length was 17.5 ± 5.8 mm, and dilatation pressure of stenting was 15.6 ± 4.1 atm. RCA ostium was covered by stent in all lesions in IVUS findings. Post dilatation was performed for 64% of lesions (balloon size 3.7 ± 0.6 mm). MACE rate at 1 year was 5.4% (target lesion revascularization 5.4%, myocardial infarction 1.2%, and no cardiac death). The biolimus A9-eluting stent for RCA ostial lesions with IVUS guidance showed favorable results at 1-year follow-up. Topics: Aged; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Japan; Male; Middle Aged; Percutaneous Coronary Intervention; Prospective Studies; Registries; Sirolimus; Treatment Outcome; Ultrasonography, Interventional | 2018 |
Effects of Coronary Artery Revascularization with a Polymer-Free Biolimus A9-Coated BioFreedom Stent Versus Bypass Surgery before Noncardiac Surgery.
The present study aimed to evaluate the efficacy and safety of polymer-free drug-coated BioFreedom stent implantation in comparison to coronary artery bypass graft (CABG) before major noncardiac surgery.. In a multicenter registry, 55 patients required revascularization before major noncardiac surgery that should not be delayed >6 months. Of them, 27 underwent BioFreedom stent implantation and 28 underwent CABG. Primary outcomes included rate of noncardiac surgery, time from revascularization to noncardiac surgery, and occurrence of composite outcomes (all-cause death, myocardial infarction, stent thrombosis, stroke, repeat revascularization, or major bleeding).. The rate of major noncardiac surgery was significantly higher in the BioFreedom group (92.6%) than in the CABG group (64.3%; p=0.027). Time from revascularization to noncardiac surgery was significantly shorter in the BioFreedom group (38.0 days) than in the CABG group (73.0 days; p=0.042). During the hospitalization for revascularization period, the occurrence of primary outcomes did not differ between the groups. However, the BioFreedom group showed a shorter hospitalization period and lower total treatment cost than the CABG group. During the hospital stay for noncardiac surgery, the occurrence of composite outcome was not significantly different between groups (4% vs. 0%; p>0.999): stroke occurred in only 1 case, and there were no cases of death or stent thrombosis in the BioFreedom group.. This study demonstrated that BioFreedom stenting as a revascularization strategy before major noncardiac surgery might be feasible and safe in selected patients with less severe coronary artery diseases. Topics: Aged; Coronary Artery Bypass; Coronary Artery Disease; Drug-Eluting Stents; Female; Hemorrhage; Humans; Male; Middle Aged; Myocardial Infarction; Sirolimus; Stroke; Treatment Outcome | 2018 |
Twelve-month outcomes of patients unsuitable for prolonged DAPT presenting with an acute coronary syndrome and treated with polymer-free biolimus A9 drug-coated stents.
Prolonged dual anti-platelet therapy (DAPT) is undesirable in certain patients. The biolimus-A9 drug-coated stent (BA9-DCS) has a rapid drug-elution profile allowing shortened DAPT.. The demographics, procedural data, and clinical outcomes for 505 patients presenting with an ACS to three UK centres and treated with a BA9-DCS stent (PCI-DCS) were collected, and compared to a consecutive ACS cohort of unselected patients treated in the same period with drug-eluting stents (PCI-DES).. PCI-DCS patients were older, more often female with hypertension, chronic kidney disease, severe LV dysfunction, and peripheral vascular disease more frequent than the PCI-DES cohort. PCI-DCS patients had a much higher Mehran bleed risk score (21.5 ± 7.7 vs. 15.9 ± 7.7, P < 0.0001). Baseline disease burden was greater in the PCI-DCS cohort with more left main and three vessel disease. During PCI, more stents (1.91 ± 1.1 vs. 1.57 ± 0.94, P < 0.0001), total stent length (38.2 ± 20.8 vs. 31.4 ± 20.3, P < 0.0001) and longer stents (38.2 ± 20.8 vs. 31.4 ± 20.3 mm, P < 0.0001) were used in the PCI-DCS cohort with rotational atherectomy also used more frequently. Physician-recommended DAPT duration was 2.9 ± 3.9 months for PCI-DCS patients and 11.3 ± 2.4 months for PCI-DES patients (P < 0.0001). At 12-month follow-up, definite stent thrombosis (0.6% vs. 1.1%) and TLR (3.2% vs. 2.7%) rates were similar between the two groups. After adjustment for baseline differences, there were no statistically significant differences in death and combined MACE rates at 12 months.. The outcomes of patients treated with polymer-free BA9 drug-coated stent who present with an ACS and who were deemed unsuitable for prolonged DAPT are encouraging. Further studies are warranted. Topics: Acute Coronary Syndrome; Aged; Aged, 80 and over; Cardiovascular Agents; Coronary Artery Disease; Drug Administration Schedule; Drug Therapy, Combination; Drug-Eluting Stents; Female; Hemorrhage; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Preliminary Data; Prosthesis Design; Retrospective Studies; Risk Assessment; Risk Factors; Sirolimus; Time Factors; Treatment Outcome; United Kingdom | 2018 |
Mid-term outcome of biolimus-eluting stents with biodegradable polymer: results from a multinational prospective 'all-comers' registry.
The Nobori biolimus-eluting stent (BES) is a biodegradable polymer drug-eluting stent (DES). Several studies have shown its noninferiority in comparison with durable polymer DES.. We sought to investigate the efficacy and the safety of Nobori BES in an all-comer population undergoing a percutaneous coronary intervention.. A total of 12 912 patients with 19 947 coronary lesions, undergoing percutaneous coronary intervention with Nobori BES implantation at 200 centres around the world between August 2010 and December 2015, were included in this prospective registry. Patients were stratified into four groups according to the total stent length, with cutoffs at 18, 24 and 28 mm. The primary endpoint was the occurrence of major adverse cardiac events defined as the composite of cardiac death, target vessel myocardial infarction and clinically driven target lesion revascularization at 1 year.. At 1 year, the major adverse cardiac events rate was the highest (4.6%) in the fourth quartile of stent length (>28 mm), whereas the overall rate of the primary endpoint in the all cohort was 3.5%. Both target lesion revascularization and target vessel revascularization rates were significantly higher in patients with longer stent length was implanted (all P<0.05). The incidence of definite and probable stent thrombosis at 1 year was 0.5% in all cohort and similar across the four groups (varying from 0.4 to 0.7%, all P=NS).. Our data confirmed the efficacy and the safety of the Nobori BES in routine clinical practice. Longer stent length is associated with a higher risk of adverse cardiac events, and yet, this risk is comparable with that of other DES. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Prosthesis Design; Registries; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2017 |
Polymer-free amphilimus-eluting stent versus biodegradable polymer biolimus-eluting stent in patients with and without diabetes mellitus.
This study sought to compare clinical outcome of polymer-free amphilimus-eluting stent (PF-AES) versus biodegradable-polymer biolimus-eluting stent (BD-BES) in "all-comer" diabetes mellitus (DM) and non-DM patients who underwent percutaneous coronary intervention.. The PF-AES has shown promising preliminary results in patients with DM.. Data from 2 multicentre-national registries (the ASTUTE and the INSPIRE-1) were used to analyse 1776 patients stratified in non-DM and DM. A double 1:1 propensity-score matched analysis (PF-AES vs. BD-BES) was performed in each group to adjust for clinical and procedural characteristics. Primary stent-efficacy and stent-safety endpoints were 1-year target-lesion revascularization (TLR) and target-lesion failure (TLF, composed of cardiac-death, target-vessel myocardial infarction and any TLR).. This matched-cohort study suggests that PF-AES has better safety and efficacy profile than BD-BES in patients with DM. Topics: Absorbable Implants; Aged; Anti-Inflammatory Agents; Cohort Studies; Coronary Artery Disease; Diabetes Mellitus; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Polymers; Registries; Sirolimus | 2017 |
Comparative Case-Control analysis of a dedicated self-expanding Biolimus A9-eluting Bifurcation stent versus provisional or mandatory side branch intervention strategies in the treatment of coronary bifurcation lesions.
In a number of coronary bifurcation lesions, both the main vessel and the side branch (SB) need stent coverage.. To analyze the procedural performance and the impact on radiation times (RT) and contrast medium consumption (CMC) of the Axxess™ stent system (Biosensors, Switzerland) treating de novo bifurcation lesions (DBL).. One hundred and ten consecutive prospectively enrolled cases (Axxess Group) and 110 age, sex, and lesion location matched controls undergoing mandatory (Group A, n = 56) or provisional (Group B, n = 54) SB intervention were analyzed.. Although more pre-dilatation was performed in the Axxess Group (92.7% vs. 46.4% [Group A] vs. 24.1% [Group B]), and more stents were used (2.4 vs. 1.2 vs. 1.05), RT and CMC were significantly lower in the Axxess Group [7.9 min/129 ml vs. 14.2 min/209 ml vs. 7.8 min/152 ml; P < 0.001]. Final Thrombolysis In Myocardial Infarction three flow in both branches was significantly more frequent in the Axxess Group (98.2% vs. 94.6% vs. 88.9%; P = 0.02), and post-interventional troponin T elevations were the lowest in the Axxess Group. Eighty one percent of the Axxess-stents could be implanted without technical difficulties. Difficult implantations procedures were mainly related to coronary anatomy. There was no safety concerns (cardiac death, stent-thrombosis) compared to controls. Cumulative 6-months MACE rates were 11% versus 23% versus 25%. TLR rates at 6-months were 5%, 18%, and 15%, respectively.. Axxess bifurcation stent system procedures were associated with significantly less RT and CMC compared to conventional DBL therapy strategies. Difficult coronary anatomy may hinder successful implantation and a learning curve has to be considered. © 2016 Wiley Periodicals, Inc. Topics: Aged; Aged, 80 and over; Cardiovascular Agents; Case-Control Studies; Contrast Media; Coronary Angiography; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Female; Germany; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Radiation Dosage; Radiation Exposure; Radiography, Interventional; Registries; Risk Factors; Sirolimus; ST Elevation Myocardial Infarction; Time Factors; Treatment Outcome | 2017 |
Long-term (8-10 years) outcomes after biodegradable polymer-coated biolimus-eluting stent implantation.
Efficacy and safety data on biodegradable polymer-coated biolimus-eluting stent (BP-BES) are currently limited to 5 years. We evaluated longer term (8-10 years) clinical and angiographic outcomes after BP-BES implantation.. Between 2005 and 2008, 243 patients (301 lesions) underwent BP-BES implantation. The primary clinical outcome measure was defined as any target lesion revascularisation (TLR). Absolute serial angiographic studies without any concomitant TLR within 2 years after the procedure were performed in 55 patients (65 lesions) at postprocedure, mid-term (within 1 year), late term (between 1 and 2 years) and very late term (beyond 2 years).. The median follow-up duration was 9.4 years (IQR 8.2-10.2 years). The 8-year cumulative incidence of any TLR was 20.3%. The increase rate was approximately 7% per year in the first 2 years, but decelerated to approximately 1.2% per year beyond 2 years after the procedure. The minimal lumen diameter significantly decreased from postprocedure (2.63±0.44 mm) to mid-term (2.43±0.59 mm, p=0.002) and from late term (2.27±0.63 mm) to very late term (1.98±0.73 mm, p=0.002). The 8-year cumulative incidences of definite or probable stent thrombosis (ST) and major bleeding (Bleeding Academic Research Consortium (BARC) ≥3) were 0.5% and 12.0%, respectively. Definite ST was none within 10 years in the entire cohort.. The long-term clinical outcomes after BP-BES implantation were favourable, although angiographic late progression of luminal narrowing did not reach a plateau. The incidence of ST remained notably low, whereas that of major bleeding gradually increased. Topics: Absorbable Implants; Aged; Coated Materials, Biocompatible; Coronary Angiography; Coronary Artery Disease; Drug-Eluting Stents; Female; Follow-Up Studies; Forecasting; Humans; Immunosuppressive Agents; Male; Myocardial Revascularization; Polymers; Prosthesis Design; Retrospective Studies; Sirolimus; Treatment Outcome | 2017 |
Two-year clinical outcomes of the NOBORI biolimus-eluting stents versus XIENCE/PROMUS everolimus-eluting stents in small vessel disease.
Biolimus-eluting stents (BES) have similar efficacy and safety compared with cobalt chromium everolimus-eluting stents (CoCr-EES), whereas it is unclear whether the same applies to small vessel disease. We sought compare clinical outcomes between BES and CoCr-EES in patients with small vessel disease.. A total of 1,132 patients treated only with BES (612 patients) or EES (520 patients) in small vessel disease (stent size 2.5-mm) were retrospectively analyzed. We assessed the cumulative 2-year incidence of major adverse cardiovascular events (MACE), defined as a composite of cardiac death, myocardial infarction (MI), definite stent thrombosis (ST), and clinically driven target lesion revascularization (CD-TLR). The cumulative 2-year incidence of MACE was similar between the two groups (12.1% vs. 11.8%, P = 0.77). The cumulative incidence of cardiac death, CD-TLR, and definite ST were also not significantly different between both groups (3.2% vs. 3.6%, P = 0.78; 8.3% vs. 8.4%, P = 1.00; 0.33% vs. 0.21%, P = 0.66, respectively). After multivariate adjusting, the adjusted risk of BES group relative to CoCr-EES group for MACE was not significantly different (hazard ratio [HR]: 0.78, 95% confidential interval [CI]: 0.53-1.15, P = 0.20). Similarly, no significant difference in the adjusted risks for cardiac death and CD-TLR were observed between the two groups (HR: 0.62, 95% CI: 0.28-1.37, P = 0.24; HR: 0.81, 95% CI: 0.51-1.29, P = 0.38).. Two-year clinical outcomes of BES are similar to those of CoCr-EES in patients with small vessel disease. The use of BES is acceptable for small coronary artery disease. © 2015 Wiley Periodicals, Inc. Topics: Aged; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Incidence; Japan; Male; Percutaneous Coronary Intervention; Postoperative Complications; Retrospective Studies; Risk Factors; Sirolimus; Survival Rate; Time Factors | 2016 |
Optical coherence tomography-based assessment of bifurcation stenting using the Axxessª Biolimus A9ª-eluting stent system.
Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Humans; Predictive Value of Tests; Prosthesis Design; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2016 |
Differences of side branch jailing between left main-left anterior descending artery stenting and left main-left circumflex artery stenting with Nobori biolimus-eluting stent.
The aim of this study is to indicate differences of side branch jailing between the left main (LM)-left anterior descending artery (LAD) stenting and the LM-left circumflex artery (LCx) stenting. Thirty-one patients who underwent single-stenting using a two-link ten-crowns biolimus-eluting stent (Japanese design of BES, J-BES) and subsequent kissing balloon dilation (KBD) on an LM bifurcation with optical coherence tomography (OCT) were divided into two groups according to the stented vessel. Bifurcation angles were measured by three-dimensional (3D) quantitative coronary analysis. The jailing pattern on a side branch ostium was evaluated by stent-enhanced 3D-OCT. Incomplete stent apposition (ISA) after KBD was compared between the stented vessels. The to-be-stented angle of the LM-LCx stenting (n = 11) was significantly steeper than that of the LM-LAD stenting (n = 20) (132.6° ± 16.9° vs. 150.7° ± 10.6°, p < 0.01). The incidence of the free carina type, which has no stent links bridging from a carina, in the LM-LCx stenting was significantly higher than that in the LM-LAD stenting (90.9 vs. 45.0 %, p = 0.02). The percentage of ISA at the bifurcation segment in the LM-LCx stenting was significantly smaller than that in the LM-LAD stenting (4.4 ± 8.2 vs. 12.7 ± 9.2 %, p = 0.0003). This study showed, by higher incidence of the favorable configuration, that the LM-LCx stenting achieved a smaller percentage of ISA than the LM-LAD stenting. These insights may help guide LM bifurcation stenting with J-BES. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Imaging, Three-Dimensional; Japan; Male; Middle Aged; Prosthesis Design; Radiographic Image Interpretation, Computer-Assisted; Retrospective Studies; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2016 |
Long-Term Clinical Outcomes of a Biodegradable Polymer-Based Biolimus-Eluting Stent.
To investigate the long-term clinical outcomes of biolimus-eluting stents with biodegradable polymers in real-world clinical practice.. Long-term clinical outcomes of biolimus-eluting stents have not been clearly established.. A total of 824 all-comer patients (971 lesions) treated with unrestricted implantation of a biolimus-eluting stent with a biodegradable polymer were prospectively enrolled. Patients were divided into complex (413 patients) versus noncomplex (411 patients) groups according to the complexity of coronary lesions. Long-term clinical outcomes for stent efficacy (target lesion revascularization) and safety (composite of cardiac death, target lesion-related myocardial infarction, and definite or probable stent thrombosis) were compared between the two groups during 5 years of follow-up.. The complex group showed higher rates of decreased left ventricular ejection fraction, impaired renal function, previous history of myocardial infarction, and diabetes mellitus compared to the noncomplex group. In the overall population, the 5-year cumulative rate of target lesion revascularization was 4.8% (8.3% in the complex group vs 1.6% in the noncomplex group, P < 0.001). For stent safety, the 5-year cumulative rate for a composite of cardiac death, target lesion-related myocardial infarction, and stent thrombosis was 2.5% overall (3.9% in the complex group vs 1.1% in the noncomplex group, P = 0.010). Overall 5-year cumulative rate of stent thrombosis was 0.4% (0.5% in the complex vs 0.2% in the noncomplex group, P = 0.561) with no very late stent thrombosis (VLST).. Biodegradable polymer-based biolimus-eluting stents showed favorable efficacy and safety in all-comer patients during 5 years of follow-up. Topics: Absorbable Implants; Aged; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Polymers; Prospective Studies; Registries; Sirolimus; Treatment Outcome | 2016 |
Biodegradable-Polymer Biolimus-Eluting Stents versus Durable-Polymer Everolimus-Eluting Stents at One-Year Follow-Up: A Registry-Based Cohort Study.
We compared outcomes of percutaneous coronary intervention patients who received biodegradable-polymer biolimus-eluting stents with those who received durable-polymer everolimus-eluting stents. At Tehran Heart Center, we performed a retrospective analysis of the data from January 2007 through December 2011 on 3,270 consecutive patients with coronary artery disease who underwent percutaneous coronary intervention with the biodegradable-polymer biolimus-eluting stent or the durable-polymer everolimus-eluting stent. We excluded patients with histories of coronary artery bypass grafting or percutaneous coronary intervention, acute ST-segment-elevation myocardial infarction, or the implantation of 2 different stent types. Patients were monitored for 12 months. The primary endpoint was a major adverse cardiac event, defined as a composite of death, nonfatal myocardial infarction, and target-vessel and target-lesion revascularization. Durable-polymer everolimus-eluting stents were implanted in 2,648 (81%) and biodegradable-polymer biolimus-eluting stents in 622 (19%) of the study population. There was no significant difference between the 2 groups (2.7% vs 2.7%; P=0.984) in the incidence of major adverse cardiac events. The cumulative adjusted probability of major adverse cardiac events in the biodegradable-polymer biolimus-eluting stent group did not differ from that of such events in the durable-polymer everolimus-eluting stent group (hazard ratio=0.768; 95% confidence interval, 0.421-1.44; P=0.388). We conclude that in our patients the biodegradable-polymer biolimus-eluting stent was as effective and safe, during the 12-month follow-up period, as was the durable-polymer everolimus-eluting stent. Topics: Absorbable Implants; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Registries; Retrospective Studies; Sirolimus; Time Factors; Treatment Outcome | 2016 |
Early Clinical Experience with a Polymer-Free Biolimus A9 Drug-Coated Stent in DES-Type Patients Who Are Poor Candidates for Prolonged Dual Anti-Platelet Therapy.
Prolonged dual anti-platelet therapy (DAPT) may cause excess bleeding in certain patients. The biolimus-A9 drug-coated stent (BA9-DCS) has a rapid drug-elution profile allowing shortened DAPT. Data were gathered on the early experience implanting this stent in drug-eluting stent eligible patients deemed to be at high risk of bleeding.. The demographics, procedural data and clinical outcomes were gathered prospectively for 249 patients treated with a BA9-DCS stent at 2 UK centres, and compared to a cohort of patients treated in the same period with drug-eluting stents (PCI-DES).. Operator-defined BA9-DCS indications included warfarin therapy, age, and anaemia. Patients receiving a BA9-DCS were older (71.6±11.8 vs. 64.8±11.6yrs, p<0.001), more often female (38.2 vs. 26.8%, P<0.001), and more likely to have comorbidity including chronic kidney disease or poor LV function than PCI-DES patients. The baseline Mehran bleed risk score was also significantly higher in the BA9-DCS group (19.4±8.7 vs. 13.1±5.8, p<0.001). Of the BA9-DCS cohort, 95.5% of patients demonstrated disease fitting NICE criteria for DES placement. The number of lesions treated (1.81±1.1 vs. 1.58±0.92, p = 0.003), total lesion length (32.1±21.7 vs. 26.1±17.6mm, p<0.001), number of stents used (1.93±1.11 vs. 1.65±1.4, p = 0.007) and total stent length (37.5±20.8 vs. 32.4±20.3, p<0.01) were greater for BA9-DCS patients. DAPT was prescribed for 3.3±3.9 months for BA9-DCS patients and 11.3±2.4 months for PCI-DES patients (p<0.001). At follow up of 392±124 days despite the abbreviated DAPT course stent related event were infrequent with ischemia-driven restenosis PCI (2.8 vs. 3.4%, p = 0.838), and stent thrombosis (1.6 vs. 2.1%, p = 0.265) rates similar between the BA9-DCS ad PCI-DES groups. After propensity scoring all clinical end-points were similar between both cohorts.. This early experience using polymer-free BA9 drug-coated stents in drug-eluting stent type patients at risk of bleeding are encouraging. Further studies are warranted. Topics: Aged; Aged, 80 and over; Aspirin; Coronary Artery Disease; Drug Therapy, Combination; Drug-Eluting Stents; Female; Hemorrhage; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Propensity Score; Prospective Studies; Risk Factors; Sirolimus; Treatment Outcome | 2016 |
Neoatherosclerosis causing occlusive in-stent restenosis: Impact of intracoronary imaging in the intensity of lipid-lowering therapy.
The unique physical properties of optical coherence tomography (OCT) make it a useful technique in the study of restenosis mechanisms. In fact, OCT is able to differentiate between neointimal proliferation and neoatherosclerosis within the stent. We report a rare case of occlusive neoatherosclerosis presenting beyond one year after a successful drug-eluting stent implantation. The impact of OCT findings in the clinical decision making process is emphasized. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Occlusion; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Humans; Hypolipidemic Agents; Male; Percutaneous Coronary Intervention; Plaque, Atherosclerotic; Retreatment; Sirolimus; Stents; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2016 |
Outcomes following implantation of the Biolimus A9-eluting BioMatrix coronary stent: Primary analysis of the e-BioMatrix registry.
To assess the safety and efficacy of Biolimus A9-eluting stents (BES, BioMatrix™ and BioMatrix Flex™) in routine clinical practice.. The LEADERS randomized trial has documented equivalent efficacy and superior safety of the BES when compared to a first generation Sirolimus-eluting Cypher(TM) stent.. 5,472 patients from 57 centers, treated with BES, were enrolled in an international multicenter registry and followed clinically up to 2 years.. Mean patient age was 63.2 ± 11 years, 24% of patients had diabetes, and 49.8% presented with an acute coronary syndrome. 99.3% of patients were discharged on dual antiplatelet therapy (DAPT), 83.3% remained on DAPT at 1 year and 30.6% at 2 years. The incidence of the composite primary end point [major adverse cardiac events (MACE) at 12 months] was 4.5% [cardiac death 0.9%, myocardial infarction 1.7%, clinically indicated target vessel revascularization (ci-TVR) 2.8%]. MACE incidence was 6.8% at 24 months (cardiac death 1.5%, myocardial infarction 2.4%, ci-TVR 4.3%). At 12 months, 32 patients (0.6%) had suffered at least one definite or probable stent thrombosis (ST), and 91 patients (1.7%) a major bleed (MB). Nine patients with ST (27.3%) and 7 patients with a MB (7.7%) died during the first year after the index procedure. Between 12 and 24 months after implantation, there were 18 (0.4%) additional MB and 8 (0.2%) additional ST.. This large international cohort documents a low 12 and 24 months MACE incidence and a very low ST incidence in an unselected patient population undergoing BES implantation. The results are in keeping with those of the randomized controlled LEADERS trial. Even though ST with this stent was a rare event, it was still associated with significant mortality. MB remains a problem, and warrants improved tailoring of DAPT in recipients of drug eluting stents. Topics: Aged; Cardiovascular Agents; Comorbidity; Coronary Artery Disease; Coronary Thrombosis; Drug Therapy, Combination; Drug-Eluting Stents; Female; Humans; Incidence; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Proportional Hazards Models; Registries; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2015 |
Bioresorbable vascular scaffolds in daily clinical practice: is the essential really invisible to the eyes?
Topics: Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Percutaneous Coronary Intervention; Postoperative Complications; Sirolimus | 2015 |
Drug-Eluting Stent Implantation on Calcified Nodule: Ex Vivo Intravascular Images and Histopathology.
Topics: Aged; Angioscopy; Autopsy; Biopsy; Cardiovascular Agents; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Fatal Outcome; Female; Humans; Percutaneous Coronary Intervention; Sirolimus; Treatment Outcome; Ultrasonography, Interventional; Vascular Calcification | 2015 |
Serial Optical Coherence Tomography Evaluation at 6, 12, and 24 Months After Biolimus A9-Eluting Biodegradable Polymer-Coated Stent Implantation.
The Nobori (Terumo Corporation, Tokyo, Japan) is a biolimus A9-eluting stent (BES) featured with a biodegradable polymer coated on the abluminal side only. We previously reported that favourable vessel healing was achieved at 6-12 months after BES implantation. However, detailed long-term vessel reaction after BES deployment is unclear.. Twenty-two BESs were serially evaluated using optical coherence tomography (OCT) at 6, 12, and 24 months after stenting. Average neointimal thickness, uncovered struts, and neointimal unevenness score (each cross-section as maximum neointimal thickness in 1 cross section divided by the average neointimal thickness of the same cross-section) were manually measured. In addition, we evaluated the percentage of struts with peri-strut low-intensity area (a region around stent struts that homogenously showed less intensity than the surrounding tissue, which suggests fibrin deposition or impaired neointima maturation), thrombi, and atherogenic neointimas (neointimas containing a diffuse border and poor-signal region with invisible struts due to marked signal attenuation).. Serial OCT observation revealed a small gradual increase in neointimal thickness from 6 to 24 months (73 ± 24 μm; 81 ± 26 μm; and 108 ± 35 μm, respectively, P = 0.001) with a nonsignificant decrease in the lumen area (6.36 ± 1.98 mm(2); 6.18 ± 2.04 mm(2); and 5.87 ± 2.06 mm(2); P = 0.72). Frequency of uncovered struts (3.89 ± 3.91%; 1.55 ± 1.63%; and 0.23 ± 0.67%; P = 0.001), neointimal unevenness score (1.95 ± 0.18% to 1.86 ± 0.19% to 1.78 ± 0.17; P = 0.012), percentage of thrombi (5%, 0%, and 0%; P = 0.37) and peri-strut low-intensity area (6.8%, 5.1%, and 1.6%; P = 0.017) decreased from 6 to 12 and 24 months. Atherogenic neointima was not observed in the event-free OCT cohort.. The Nobori stent achieved acceptable long-term vessel healing, mostly without adverse vessel reactions. Topics: Aged; Coated Materials, Biocompatible; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Neointima; Polymers; Prospective Studies; Prosthesis Design; Reproducibility of Results; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2015 |
Comparison of abluminal biodegradable polymer biolimus-eluting stents and durable polymer everolimus-eluting stents in the treatment of coronary bifurcations.
To compare biodegradable polymer biolimus-eluting (BES) with abluminal drug elution and durable polymer everolimus-eluting (EES) stents in the treatment of bifurcation lesions.. The persistence of a polymer in drug-eluting stents (DES) following drug elution has been viewed as a possible culprit for restenosis. DES with biodegradable polymer may thus be associated with improved clinical outcomes, especially in high-risk lesions such as those at bifurcation sites.. We performed a retrospective study of consecutive de novo bifurcation lesions treated with EES between October 2006 and October 2011 and BES between February 2008 and March 2012. Study endpoints included major adverse cardiac events (MACE) defined as all-cause death, myocardial infarction (MI), including peri-procedural MI, and target vessel revascularization (TVR) as well as target lesion revascularization (TLR) separately.. We analyzed 236 bifurcation lesions treated with either BES (79 lesions in 69 patients) or EES (157 lesions in 154 patients). Patient and procedural characteristics were broadly similar between the two groups. Estimated MACE and TVR rates at 2-year follow-up were similar between the BES and EES groups (MACE = 13.6 ± 4.6% vs. 14.6 ± 3.2% (P = 0.871); TVR = 6.9 ± 3.5% vs. 8.0 ± 2.7% (P = 0.889). No significant differences were noted between the two groups following propensity-score matched analysis. There was no probable or definite stent thrombosis.. BES use in the treatment of bifurcation lesions appears to be associated with good clinical outcomes, comparable to those seen with EES, at long-term follow-up. These results are hypothesis-generating and need to be validated with larger studies. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Retrospective Studies; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2014 |
Clinical outcomes with 6 months dual antiplatelet therapy after implantation of biolimus-A9 drug eluting coronary stents.
Duration of dual antiplatelet therapy (DAPT) following drug eluting stent (DES) implantation remains poorly defined. Endothelialisation of biodegradable polymer biolimus-eluting stents occurs early, and 6 months DAPT may be adequate.. We evaluated long term outcome in patients treated with biolimus-eluting stents who were treated with 6 months DAPT. Endpoints included cardiac death and non-fatal stent thrombosis occurring 6 to 12 months after stent implantation.. 692 patients (77.2% male), aged 65.6 ± 12.5 years received biolimus-eluting DES (March 2008 -November 2011). Vital status was tracked through the Medical Research Information Service. Episodes of non-fatal stent thrombosis, (Academic Research Consortium definition) between months 6 and 12 were tracked via systematic database searches (5 PCI centres).. Presentations included acute coronary syndrome (47.2%) and stable coronary disease (52.8%). Vessels treated included left main stem (6.8%), left anterior descending (37.4%), circumflex (19.1%), right coronary artery (34.5%) and saphenous vein graft (2.1%) respectively. High-risk subsets included diabetes (15.6%); AHA type C lesions (35.1%) and chronic total occlusions (12.8%). During median follow-up of 700 days (0 to 1392) there were 42 deaths (6.1%); 4.2% at 0-6 months, 1.0% at 6-12 months and 0.9% at >12 months. Of the 7 deaths between 6 and 12 months, one death was adjudicated as possible stent thrombosis. There were no cases of non-fatal known stent thrombosis. All cause mortality accrued with smooth decremental incidence. Statistical examination showed no evidence of event clustering between 6 and 12 months.. After implantation of biodegradable polymer biolimus-eluting coronary stents, 6 months DAPT appears to be adequate, safe and effective. Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Coronary Artery Disease; Coronary Thrombosis; Drug Therapy, Combination; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Platelet Aggregation Inhibitors; Retrospective Studies; Risk Factors; Sirolimus; Survival Analysis; Treatment Outcome | 2014 |
Incidence and clinical impact of stent fracture after the Nobori biolimus-eluting stent implantation.
Stent fracture (SF) after drug-eluting stent implantation has become an important concern. The aim of this study was to assess the incidence, predictors, and clinical impact of SF after biolimus-eluting stent.. A total of 1026 patients with 1407 lesions undergoing the Nobori biolimus-eluting stent implantation and follow-up angiography within 9 months after index procedure were analyzed. SF was defined as complete or partial separation of the stent, as assessed by using plain fluoroscopy, intravascular ultrasound, or optical coherence tomography during the follow-up. We assessed the rate of SF and the cumulative incidence of clinically driven target lesion revascularization and definite stent thrombosis within 9 months. SF was observed in 58 (4.1%) of 1407 lesions and 57 (5.5%) of 1026 patients. Lesions with hinge motion (OR 8.90, 95% CI 3.84 to 20.6, P<0.001), tortuosity (OR 4.16, 95% CI 1.75 to 9.88, P=0.001), and overlapping stents (OR 2.41, 95% CI 0.95 to 6.10, P=0.06) were predictors of SF. Cumulative incidence of clinically driven target lesion revascularization within 9 months was numerically higher in the SF group than that in the non-SF group (12.0% versus 1.0%). Cumulative incidence of definite stent thrombosis within 9 months tended to be higher in the SF group than that in the non-SF group (1.7% versus 0.5%).. SF after biolimus-eluting stent occurs in 4.1% of lesions and appears to be associated with clinically driven target lesion revascularization. Topics: Aged; Aged, 80 and over; Cardiovascular Agents; Chi-Square Distribution; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Incidence; Japan; Logistic Models; Male; Middle Aged; Multivariate Analysis; Odds Ratio; Percutaneous Coronary Intervention; Prosthesis Design; Prosthesis Failure; Risk Factors; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2014 |
Treatment of coronary bifurcations with third generation drug-eluting stent: making major headway or just baby steps?
Topics: Absorbable Implants; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Percutaneous Coronary Intervention; Polymers; Sirolimus | 2014 |
Very long-term follow-up of strut apposition and tissue coverage with Biolimus A9 stents analyzed by optical coherence tomography.
First generation drug-eluting stents (DES) are associated with reduced in-stent restenosis but significant increased risk of very late stent thrombosis (VLST). The absence of polymer in DES systems may reduce the occurrence of VLST. Optic coherence tomography (OCT) has been used for stent analysis as a surrogate safety endpoint. This study aimed to assess the long-term follow up of strut apposition and tissue coverage of BioMatrix DES by OCT. 20 patients undergoing BioMatrix DES (n = 15) or S-Stent BMS (n = 5) implantation were followed for at least 5 years and evaluated by quantitative coronary angiography, intravascular ultrasound, and OCT. The difference between the stent types was evaluated by nonparametric Mann-Whitney U test while categorical variables were evaluated by Fisher exact test. Rates of in-stent late loss were similar between groups [0.40 (0.21;0.77) vs. 0.68 (0.66; 0.82) mm, p = 0.205, for BioMatrix and S-Stent, respectively]. The vessel, stent and lumen volumes did not differ between groups. Patients treated with BioMatrix had significantly less stent obstruction [5.6 (4.4;9.7) vs. 28.6 (24.7;29.0) %, p = 0.001]. OCT analysis of 12 stents (Biomatrix = 9 and S-Stent = 3) demonstrated 126 (8.7 %) uncovered struts in the BioMatrix group compared to 23 (4.0 %) in the S-Stent group (p = 0.297), being the majority of them well apposed (117/126 and 21/23, respectively, p = 0.292). Only 9 (0.6 %) struts in the DES and 2 (0.4 %) struts in the BMS groups were simultaneously uncovered and malapposed (p = 0.924). BioMatrix DES was associated with lower rates of in-stent obstruction, and similar percentage of neointimal coverage on struts and of complete strut apposition. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Predictive Value of Tests; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2013 |
Long-term comparison of everolimus-eluting and biolimus-eluting stents.
Second-generation everolimus-eluting stents (EES) are safer and more efficient than first-generation paclitaxel-eluting stents (PES). Third-generation biolimus-eluting stents (BES) have been found to be non-inferior to PES. To date, there is no available comparative study between EES and BES. We aimed to investigate the safety and efficacy of BES with biodegradable polymer compared to EES with durable polymer at a follow-up of two years in an unselected population of consecutively enrolled patients.. A group of 814 consecutive patients undergoing percutaneous coronary intervention (PCI) was enrolled between 2007 and 2010, of which 527 were treated with EES and 287 with BES implantation. Clinical outcome was compared in 200 pairs using propensity score matching. The primary endpoint was a composite of death, myocardial infarction (MI) and target vessel revascularisation (TVR) at two-year follow-up. Median follow-up was 22 months. The primary outcome occurred in 11.5% of EES and 10.5% of BES patients (HR 1.11, 95% CI: 0.61-2.00, p=0.74). At two years, there was no significant difference with regard to death (HR 0.49, 95% CI: 0.18-1.34, p=0.17), cardiac death (HR 0.14, 95% CI: 0.02-1.14, p=0.66) or MI (HR 6.10, 95% CI: 0.73-50.9, p=0.10). Stent thrombosis (ST) incidence was evenly distributed between EES (n=2) and BES (n=2) (p-value=1.0).. This first clinical study failed to demonstrate any significant difference regarding safety or efficacy between these two types and generations of drug-eluting stents (DES). Topics: Aged; Cardiovascular Agents; Chi-Square Distribution; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Multivariate Analysis; Myocardial Infarction; Percutaneous Coronary Intervention; Propensity Score; Proportional Hazards Models; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2013 |
New-generation drug-eluting stent experience in the percutaneous treatment of unprotected left main coronary artery disease: the NEST registry.
To explore the 2-year clinical outcomes in patients with unprotected left main coronary artery (ULMCA) disease treated with overall new drug-eluting stent (DES) options.. Recent available data have shown the feasibility and the safety of new DESs, mainly evaluating the everolimus-eluting stents in the setting of ULMCA disease.. Patients with ULMCA disease undergoing percutaneous coronary intervention (PCI) with everolimus-, zotarolimus-, and biolimus A9-eluting stents were prospectively evaluated. The study objective was the composite of major adverse cardiac events (MACEs), consisting of all-cause mortality, myocardial infarction (MI), and target vessel revascularization (TVR) at 2-year clinical follow-up.. A total of 154 patients were analyzed. The mean EuroSCORE and SYNTAX scores were 4.7 ± 2.6 and 27.5 ± 8.3, respectively. Distal location was present in 126 patients (81.8%) and 96 lesions (76.3%) were true Medina bifurcations. The 2-stent technique was used in 73 cases (57.9%). Everolimus-, zotarolimus-, and biolimus A9-eluting stents were implanted in 68 patients (44.2%), 46 patients (29.9%), and 40 patients (25.9%), respectively. At a median clinical follow-up of 551.5 days (interquartile range, 360.8-1045.5 days), MACEs occurred in 29 patients (18.8%). Ten patients (6.5%) died, and 2 deaths (1.3%) were adjudicated as cardiac. No patient had myocardial infarction or definite stent thrombosis (ST). One probable and 1 possible ST were adjudicated. TVR was required in 19 patients (12.3%) and target lesion revascularization was required in only 7 patients (4.5%).. In our experience, despite the presence of complex distal left main lesions, new DESs in ULMCA disease appear to be promising in terms of safety and efficacy at 2-year clinical follow-up. Topics: Aged; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Follow-Up Studies; Humans; Incidence; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Registries; Retrospective Studies; Sirolimus; Thrombosis; Treatment Outcome | 2013 |
SORT OUT V: a new episode in the DES wars.
Topics: Absorbable Implants; Acute Coronary Syndrome; Coated Materials, Biocompatible; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Male; Sirolimus | 2013 |
An optical coherence tomography study of two new generation stents with biodegradable polymer carrier, eluting paclitaxel vs. biolimus-A9.
Tissue coverage and strut apposition of drug eluting stents (DES), which can be assessed with optical coherence tomography (OCT), may be associated with late stent thrombosis (LST).. Prospective observational angiographic and OCT follow-up at 6 months post-implantation of a biolimus-A9 eluting stent (BES) vs. a paclitaxel eluting stent (PES), with biodegradable polymer carriers. The primary outcome was the percent difference of uncovered struts between BESs and PESs.. A maximum likelihood model was used for analysis, to account for data clustering. Sixteen patients were treated with BES (28 lesions/4530 struts) and 16 with PES (23 lesions/4450 struts). Overall, BESs compared to PESs had more uncovered [0.41% vs. 0.21%, difference estimate (DE) 0.2 (95% CI, 0.06-0.34), p=0.006], malapposed [0.18% vs. 0.04%, DE 0.14 (95% CI 0.05-0.23), p=0.003], uncovered and malapposed [0.08% vs. 0.026%, DE 0.057 (95% CI 0.015-0.1), p=0.01] and protruding struts [0.23% vs. 0.04%, DE 0.185 (95% CI 0.1-0.27), p<0.001], and significantly lower neointimal thickness (59.3 ± 28.2 μm vs. 201.7 ± 97.5, p<0.001). None of the BESs was totally covered with neointima, in contrast to 5 (21.7%) PESs (p=0.01). Thrombus was detected in 1 (3.6%) BES and 5 (21.7%) PESs (p=0.05); however, no patient experienced clinical stent thrombosis.. Between two stents with biodegradable polymer, OCT demonstrated that BESs had more uncovered and malapposed struts compared to PESs at 6 months. This difference might be partly attributed to the more potent antiproliferative properties of biolimus-A9; however, its impact on clinical outcome and on the risk of LST is yet to be determined. Topics: Absorbable Implants; Aged; Coronary Artery Disease; Drug Carriers; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Paclitaxel; Polymers; Prospective Studies; Radiography; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2012 |
Clinical performance of a drug-eluting stent with a biodegradable polymer in an unselected patient population: the NOBORI 2 study.
Previous studies for approved indications (on-label) have shown the good safety and efficacy profiles of the Nobori DES. We conducted a prospective, multicentre study to validate the clinical performance of this stent in a real-world setting.. A total of 3,067 consecutive patients undergoing a percutaneous coronary intervention with the Nobori DES were enrolled in the NOBORI 2 registry. At one and two years, 97% and 95% of patients, respectively, were available for follow-up. The rates of target lesion failure (TLF), cardiac death, myocardial infarction and target lesion revascularisations were: 3.9%, 1.2%, 1.9% and 2.2% at one year and 5.1%, 1.6%, 2.4% and 3.0% at two years. Overall, 2,242 patients (73%) were treated for at least one off-label indication. When comparing off-label and on-label groups, the results were: TLF 4.5% vs. 2.2%, p=0.003 at one year and 5.9% vs. 2.8%, p=0.001 at two years. The rate of stent thrombosis was 0.68%, and 0.80% at one and two years, respectively with no difference between the off-label and on-label groups (0.76% vs. 0.48%, p=0.6 and 0.89% vs. 0.61%, p=0.5).. The promising results previously observed in lower risk patients can be replicated in daily practice. As expected, in off-label indications, rates of adverse events were higher. Nevertheless, our results suggest the good and sustained performance of this stent system in high-risk patients with significant comorbidities and/or complex lesions. Topics: Absorbable Implants; Aged; Analysis of Variance; Angioplasty, Balloon, Coronary; Asia; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Europe; Female; Guideline Adherence; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Polymers; Practice Guidelines as Topic; Product Labeling; Prospective Studies; Prosthesis Design; Registries; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2012 |
Polymer drug-eluting stents: is the future biodegradable?
Topics: Absorbable Implants; Coronary Artery Disease; Drug-Eluting Stents; Humans; Polymers; Sirolimus | 2011 |
The AXXESS™ self-expanding biolimus A9™ eluting stent system for coronary bifurcation lesions.
Topics: Angioplasty, Balloon, Coronary; Animals; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Drug-Eluting Stents; Humans; Materials Testing; Patient Selection; Prosthesis Design; Sirolimus; Treatment Outcome | 2010 |
Reproducibility of quantitative optical coherence tomography for stent analysis.
To assess the inter- and intra- observer reproducibility for strut count, strut apposition and strut tissue coverage measurements with optical coherence tomography (OCT).. Ten drug-eluting stents (244 frames, 1712 struts) imaged with OCT nine months after implantation were analysed by two independent analysts. One of the analysts repeated the analysis of five stents (120 frames, 795 struts) one week later. Offline analysis was performed with the proprietary LightLab Imaging software. The number of struts was counted and lumen and stent area contours were traced. Tissue coverage thickness was measured at 360 degrees of vessel circumference and in front of every individual strut. The number of malapposed struts was determined. There was good agreement for strut number count (Kendall's Tau-b 0.90 for inter- and 0.94 for intra- observer variability). The relative difference for lumen area, stent area and tissue coverage measurements was around 1%. There was complete inter- and intra- observer agreement for malapposed struts classification (4 out of 1708 struts, Kappa=1).. In a Corelab setting, the inter- and intra- observer reproducibility for strut count, strut apposition and strut tissue coverage measurements with OCT is excellent. This emphasises the value of OCT as a tool for the clinical long-term assessment of stents. Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Humans; Image Interpretation, Computer-Assisted; Observer Variation; Predictive Value of Tests; Prosthesis Design; Reproducibility of Results; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2009 |
Long-term outcome after the V stenting technique in de novo bifurcation lesions using drug-eluting stents.
To report long-term outcome data on the V technique using drug-eluting stents.. From April 2002 to December 2006, 31 consecutive patients were successfully treated with V stenting of a de novo bifurcation lesion. The technique involves the deployment of two stents in the two branches of a bifurcation, the proximal edges of the stents just touching one another. Patients exclusively received either sirolimus- (10), paclitaxel- (20) or biolimus-eluting (one) stents. On average, 1.5 +/- 0.8 stents with a total length of 26.6 +/- 17.2 mm and 1.1 +/- 0.4 stents with a total length of 18.3 +/- 7.6 mm were deployed in the distal main vessel and side branch respectively. Mean duration of follow-up was 853 +/- 553 days. Within 30 days, three patients died; two other patients had definite stent thrombosis involving the V stents, both requiring re-PCI. Beyond 30 days and within one year, there was one death and three cases of target vessel revascularisation, including one target lesion revascularisation. There were a further three deaths (one cardiac) beyond one year. Eleven patients (35.5%) had angiographic follow-up, exhibiting a binary restenosis rate of 9.1% at 203 +/- 33 days.. In this real-world cohort, late clinical events stand in accord with studies on competitive techniques, but early outcome was less encouraging, probably due to the baseline risks. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Netherlands; Paclitaxel; Prosthesis Design; Registries; Retrospective Studies; Risk Assessment; Risk Factors; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2009 |
Results of percutaneous coronary intervention of the unprotected left main coronary artery in 143 patients and comparison of 30-day mortality to results of coronary artery bypass grafting.
Percutaneous coronary intervention (PCI) of the unprotected left main coronary artery (LMCA) is controversial. In 143 patients who underwent PCI of the unprotected LMCA, 30-day mortality was compared with predicted cumulative risk-adjusted perioperative surgical mortality based on logistic European System for Cardiac Operative Risk Evaluation. One-year clinical follow-up was completed in all patients. The overall major adverse cardiac event rate at 1 year was 34.3%, reflecting the high-risk profile of the patient population. Twelve patients (8%) experienced an acute myocardial infarction and 16 (11%) underwent target lesion revascularization. In 31 patients (22%) who died during the first year, median logistic European System for Cardiac Operative Risk Evaluation was 30%. Calculated RRs showed significantly lower 30-day mortality using PCI compared with predicted surgical mortality (RR 0.54, 95% confidence interval 0.31 to 0.86). Angiographic follow-up in 90 of the 118 patients alive at 6 months showed binary restenosis of 6% in patients treated with drug-eluting stents versus 29% in patients receiving bare-metal stents (p < or =0.01). In conclusion, PCI for unprotected LMCA disease was associated with acceptable short- and medium-term outcomes in patients at low to intermediate risk of bypass surgery. Mortality remains high in very high-risk patients unsuitable for surgery. However, in selected indications, PCI of the LMCA can offer an alternative to surgery, especially when using drug-eluting stents. Topics: Acute Coronary Syndrome; Aged; Aged, 80 and over; Angioplasty, Balloon, Coronary; Coronary Artery Bypass; Coronary Artery Disease; Coronary Restenosis; Female; Humans; Male; Myocardial Infarction; Outcome Assessment, Health Care; Retreatment; Risk Adjustment; Sirolimus; Stents | 2008 |
Bifurcation stenting with a dedicated biolimus-eluting stent: X-ray visual enhancement of the final angiographic result with "StentBoost Subtract".
A 51 year-old man underwent percutaneous coronary intervention of a significant "true" bifurcation lesion involving the proximal left anterior descendens (LAD) artery and an important first diagonal branch with a dedicated bifurcation stent, which is a conical self-expandable biolimus-eluting stent with a "flared" distal part allowing for optimal scaffolding of the carina of the bifurcation, and two additional sirolimus-eluting stents, deployed with the V-stenting technique, one in the LAD and one in the diagonal branch, in overlap with the distal part of the "flared" biolimus-eluting stent. An X-ray enhancing visualization technique, "StentBoost Subtract," was used to obtain an improved visualization of the stent in relation to the corresponding vessel lumen and revealed good expansion of all the stents and good apposition to the vessel wall. Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Cineangiography; Contrast Media; Coronary Angiography; Coronary Artery Disease; Humans; Male; Middle Aged; Prosthesis Design; Radiographic Image Interpretation, Computer-Assisted; Radiography, Interventional; Severity of Illness Index; Sirolimus; Stents | 2007 |