Page last updated: 2024-08-22

titanium and Compression Fractures

titanium has been researched along with Compression Fractures in 12 studies

Research

Studies (12)

TimeframeStudies, this research(%)All Research%
pre-19900 (0.00)18.7374
1990's0 (0.00)18.2507
2000's2 (16.67)29.6817
2010's7 (58.33)24.3611
2020's3 (25.00)2.80

Authors

AuthorsStudies
Chung, TT; Liang, HC; Lin, CL; Tang, CT1
Levy, JR1
Blondel, B; Fuentes, S; Gonzalez, AM; Hassel, F; Kaya, JM; Maestretti, G; Marcia, S; Noriega, D; Petit, A; Pflugmacher, R; Simon, A; Theumann, N; Touta, A; Weidle, PA1
Beall, DP; Deschamps, F; Filippiadis, DK; Kelekis, A; Marcia, S; Masala, S; Ryan, A1
Blondel, B; Fuentes, S; Hassel, F; Kaya, JM; Maestretti, G; Mandly, AG; Marcia, S; Noriega, D; Petit, A; Pflugmacher, R; Simon, A; Theumann, N; Touta, A; Weidle, PA1
Barzilay, Y; Cohen, JE; Fraifeld, S; Itshayek, E; Kaplan, L; Rosenthal, G; Schroeder, J; Shoshan, Y; Vargas, AA1
Ender, SA; Eschler, A; Gradl, G; Herlyn, P; Mittlmeier, T; Ulmar, B1
Aragón, FA; Baeesa, SS; Krueger, A; Noriega, DC1
Lee, D; Mahar, AT; Robertson, C; Tomlinson, T; Upasani, VV1
Garfin, S; Ghofrani, H; Lee, Y; Mahar, A; Nunn, T; Robertson, C1
Chen, CH; Hsieh, CH; Li, AF; Li, KC; Liao, TH1
Chen, HH; Hsieh, CH; Li, AF; Li, KC1

Reviews

1 review(s) available for titanium and Compression Fractures

ArticleYear
New Implant-Based Technologies in the Spine.
    Cardiovascular and interventional radiology, 2018, Volume: 41, Issue:10

    Topics: Aged; Combined Modality Therapy; Dilatation; Female; Fractures, Compression; Humans; Kyphoplasty; Lumbar Vertebrae; Male; Middle Aged; Minimally Invasive Surgical Procedures; Prostheses and Implants; Spinal Fractures; Spinal Stenosis; Stents; Surgical Mesh; Thoracic Vertebrae; Titanium

2018

Trials

2 trial(s) available for titanium and Compression Fractures

ArticleYear
A prospective, international, randomized, noninferiority study comparing an implantable titanium vertebral augmentation device versus balloon kyphoplasty in the reduction of vertebral compression fractures (SAKOS study).
    The spine journal : official journal of the North American Spine Society, 2019, Volume: 19, Issue:11

    Topics: Aged; Aged, 80 and over; Bone Cements; Equivalence Trials as Topic; Female; Fracture Fixation, Internal; Fractures, Compression; Humans; Infant; Internal Fixators; Kyphoplasty; Male; Middle Aged; Osteoporotic Fractures; Pain; Prospective Studies; Quality of Life; Radiography; Spinal Fractures; Titanium; Treatment Outcome

2019
Cementless fixation of osteoporotic VCFs using titanium mesh implants (OsseoFix): preliminary results.
    BioMed research international, 2014, Volume: 2014

    Topics: Aged; Bone Cements; Female; Fracture Fixation; Fractures, Compression; Humans; Male; Osteoporosis; Pain Measurement; Prostheses and Implants; Radiography; Spinal Fractures; Titanium

2014

Other Studies

9 other study(ies) available for titanium and Compression Fractures

ArticleYear
Biomechanical evaluation of a novel tri-blade titanium implantable vertebral augmentation device.
    The spine journal : official journal of the North American Spine Society, 2023, Volume: 23, Issue:5

    Topics: Animals; Bone Cements; Fractures, Compression; Osteoporosis; Spinal Fractures; Spine; Swine; Titanium; Treatment Outcome

2023
Letter to the editor regarding: "a prospective, international, randomized, noninferiority study comparing an implantable titanium vertebral augmentation device versus balloon kyphoplasty in the reduction of vertebral compression fractures (SAKOS study)".
    The spine journal : official journal of the North American Spine Society, 2020, Volume: 20, Issue:12

    Topics: Fractures, Compression; Humans; Kyphoplasty; Osteoporotic Fractures; Prospective Studies; Spinal Fractures; Titanium

2020
A prospective, international, randomized, noninferiority study comparing an titanium implantable vertebral augmentation device versus balloon kyphoplasty in the reduction of vertebral compression fractures (SAKOS study).
    The spine journal : official journal of the North American Spine Society, 2020, Volume: 20, Issue:12

    Topics: Fractures, Compression; Humans; Kyphoplasty; Osteoporotic Fractures; Prospective Studies; Spinal Fractures; Titanium

2020
Efficacy and safety of vertebral stenting for painful vertebral compression fractures in patients with metastatic disease.
    Neurological research, 2014, Volume: 36, Issue:12

    Topics: Back Pain; Fractures, Compression; Humans; Kyphoplasty; Male; Pain Measurement; Spinal Fractures; Spinal Neoplasms; Stents; Titanium; Treatment Outcome

2014
The efficacy of a percutaneous expandable titanium device in anatomical reduction of vertebral compression fractures of the thoracolumbar spine.
    Saudi medical journal, 2015, Volume: 36, Issue:1

    Topics: Adult; Aged; Aged, 80 and over; Female; Fracture Fixation, Internal; Fractures, Compression; Humans; Imaging, Three-Dimensional; Internal Fixators; Lumbar Vertebrae; Male; Middle Aged; Prospective Studies; Spinal Fractures; Thoracic Vertebrae; Titanium; Tomography, X-Ray Computed; Treatment Outcome; Young Adult

2015
Biomechanical comparison of kyphoplasty versus a titanium mesh implant with cement for stabilization of vertebral compression fractures.
    Spine, 2010, Sep-01, Volume: 35, Issue:19

    Topics: Aged; Biomechanical Phenomena; Bone Cements; Cadaver; Equipment Design; Fracture Fixation; Fractures, Compression; Humans; Joint Instability; Kyphoplasty; Lumbar Vertebrae; Male; Middle Aged; Orthopedic Fixation Devices; Polymethyl Methacrylate; Spinal Fractures; Thoracic Vertebrae; Titanium; Tomography, X-Ray Computed; Weight-Bearing

2010
An evaluation of fracture stabilization comparing kyphoplasty and titanium mesh repair techniques for vertebral compression fractures: is bone cement necessary?
    Spine, 2010, Jul-15, Volume: 35, Issue:16

    Topics: Aged; Aged, 80 and over; Biomechanical Phenomena; Bone Cements; Cadaver; Female; Fractures, Compression; Humans; Joint Instability; Kyphoplasty; Male; Outcome Assessment, Health Care; Polymethyl Methacrylate; Spinal Fractures; Surgical Mesh; Titanium

2010
Another option to treat Kümmell's disease with cord compression.
    European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2007, Volume: 16, Issue:9

    Topics: Aged; Aged, 80 and over; Female; Fractures, Compression; Humans; Internal Fixators; Kyphosis; Male; Middle Aged; Orthopedic Procedures; Osteoporosis; Retrospective Studies; Spinal Cord Compression; Titanium; Treatment Outcome

2007
Transpedicle body augmenter in painful osteoporotic compression fractures.
    European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2007, Volume: 16, Issue:5

    Topics: Aged; Aged, 80 and over; Analysis of Variance; Female; Follow-Up Studies; Fractures, Compression; Humans; Internal Fixators; Kyphosis; Male; Middle Aged; Osteoporosis; Pain; Radiography; Retrospective Studies; Spinal Fractures; Titanium

2007