Page last updated: 2024-08-22

titanium and Abnormality, Torsion

titanium has been researched along with Abnormality, Torsion in 12 studies

Research

Studies (12)

TimeframeStudies, this research(%)All Research%
pre-19901 (8.33)18.7374
1990's5 (41.67)18.2507
2000's5 (41.67)29.6817
2010's1 (8.33)24.3611
2020's0 (0.00)2.80

Authors

AuthorsStudies
Bloemke, AD; Clarke, HD; Roberts, CC; Roper, GE; Spangehl, MJ1
Gerdesmeyer, L; Kraus, W; Lehner, S; Matter, HP; Mittelmeier, W; Steinhauser, E1
Borges, PC; de Oliveira, FT; Ferreira, Mdo A; Ignácio, SA1
Eppley, BL; Ge, J; Katona, T; McCarty, M; Moore, K; Prevel, CD1
Caputo, AA; Kelso, I; Shetty, V1
Filleul, MP; Jordan, L1
Bassett, T; Cooke, ME; Ghanayem, AJ; Markel, M; Rapoff, AJ; Swain, C; Zdeblick, TA1
Powers, JM; Svec, TA2
Cunningham, CJ; Hilt, BR; Richards, N; Shen, C1
Messer, HH; Nervo, GJ; Palamara, JE; Sattapan, B1
Brettle, J; Hughes, AN; Jordan, BA1

Other Studies

12 other study(ies) available for titanium and Abnormality, Torsion

ArticleYear
Analysis of tibial component rotation following total knee arthroplasty using 3D high definition computed tomography.
    The Journal of arthroplasty, 2013, Volume: 28, Issue:8 Suppl

    Topics: Arthroplasty, Replacement, Knee; Chromium; Cobalt; Humans; Imaging, Three-Dimensional; Knee Prosthesis; Observer Variation; Reproducibility of Results; Tibia; Titanium; Tomography, X-Ray Computed; Torsion Abnormality

2013
BISS: concept and biomechanical investigations of a new screw system for electromagnetically induced internal osteostimulation.
    Archives of orthopaedic and trauma surgery, 2004, Volume: 124, Issue:2

    Topics: Alloys; Biomechanical Phenomena; Bone Screws; Electrodes; Electromagnetic Fields; Humans; Materials Testing; Stress, Mechanical; Titanium; Torsion Abnormality

2004
Experimental force definition system for a new orthodontic retraction spring.
    The Angle orthodontist, 2005, Volume: 75, Issue:3

    Topics: Dental Stress Analysis; Humans; Materials Testing; Molybdenum; Orthodontic Appliance Design; Orthodontic Appliances; Orthodontic Wires; Titanium; Tooth Movement Techniques; Torsion Abnormality

2005
A biomechanical analysis of the stability of titanium bone fixation systems in proximal phalangeal fractures.
    Annals of plastic surgery, 1996, Volume: 37, Issue:5

    Topics: Biomechanical Phenomena; Cadaver; Finger Injuries; Humans; Internal Fixators; Titanium; Torsion Abnormality

1996
Torsion-axial force characteristics of SR-PLLA screws.
    Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery, 1997, Volume: 25, Issue:1

    Topics: Biodegradation, Environmental; Bone Screws; Equipment Design; Equipment Failure; Materials Testing; Polyesters; Stress, Mechanical; Surface Properties; Titanium; Torque; Torsion Abnormality

1997
Torsional properties of Ni-Ti and copper Ni-Ti wires: the effect of temperature on physical properties.
    European journal of orthodontics, 1997, Volume: 19, Issue:6

    Topics: Body Temperature; Calorimetry, Differential Scanning; Chemical Phenomena; Chemistry, Physical; Cold Temperature; Copper; Crystallography; Dental Alloys; Elasticity; Hot Temperature; Humans; Materials Testing; Nickel; Orthodontic Wires; Stress, Mechanical; Temperature; Titanium; Torsion Abnormality

1997
Cervical interbody fusion cages. An animal model with and without bone morphogenetic protein.
    Spine, 1998, Apr-01, Volume: 23, Issue:7

    Topics: Animals; Bone Morphogenetic Protein 2; Bone Morphogenetic Proteins; Bone Regeneration; Cervical Vertebrae; Compressive Strength; Diskectomy; Female; Fluorescent Dyes; Goats; Joints; Materials Testing; Prostheses and Implants; Radiography; Recombinant Proteins; Spinal Fusion; Titanium; Torsion Abnormality; Transforming Growth Factor beta

1998
Effects of simulated clinical conditions on nickel-titanium rotary files.
    Journal of endodontics, 1999, Volume: 25, Issue:11

    Topics: Analysis of Variance; Dental High-Speed Technique; Dental Instruments; Nickel; Rotation; Titanium; Torsion Abnormality

1999
Torsional properties of stainless-steel and nickel-titanium files after multiple autoclave sterilizations.
    Journal of endodontics, 2000, Volume: 26, Issue:2

    Topics: Acid Etching, Dental; Analysis of Variance; Dental Alloys; Epoxy Resins; Equipment Design; Equipment Failure; Hardness; Hot Temperature; Humans; Linear Models; Materials Testing; Nickel; Root Canal Preparation; Stainless Steel; Sterilization; Stress, Mechanical; Surface Properties; Titanium; Torsion Abnormality

2000
Defects in rotary nickel-titanium files after clinical use.
    Journal of endodontics, 2000, Volume: 26, Issue:3

    Topics: Dental Alloys; Equipment Design; Equipment Failure; Humans; Materials Testing; Microscopy, Electron, Scanning; Nickel; Pliability; Root Canal Preparation; Rotation; Stress, Mechanical; Surface Properties; Titanium; Torsion Abnormality

2000
A method to assess rotary nickel-titanium files.
    Journal of endodontics, 2000, Volume: 26, Issue:9

    Topics: Analysis of Variance; Dental High-Speed Equipment; Dental Stress Analysis; Equipment Failure; Materials Testing; Nickel; Root Canal Preparation; Statistics, Nonparametric; Titanium; Torsion Abnormality

2000
Metallurgical aspects of surgical implant materials.
    Injury, 1971, Volume: 2, Issue:3

    Topics: Alloys; Biodegradation, Environmental; Biomechanical Phenomena; Chromium Alloys; Cobalt; Corrosion; Elasticity; Hardness Tests; Metals; Prostheses and Implants; Stainless Steel; Stress, Mechanical; Titanium; Torsion Abnormality

1971