technetium-tc-99m-tetrofosmin has been researched along with Kidney-Diseases* in 3 studies
3 other study(ies) available for technetium-tc-99m-tetrofosmin and Kidney-Diseases
Article | Year |
---|---|
Single-shot cardiorenal scintigraphy with 99mTc-tetrofosmin: a dynamic characterization at rest and during adenosine infusion.
Renal function is known to be a strong predictor of cardiovascular prognosis, and cardiorenal disease is increasingly investigated in medical research. In this study, we tested the hypothesis that a single combined cardiorenal scintigraphy examination with the perfusion tracer (99m)Tc-tetrofosmin is feasible and may allow the simultaneous investigation of cardiac and renal pathology in cardiovascular patients.. Thirty patients scheduled for dual-day gated SPECT also gave their informed consent for a renal acquisition after a single injection of 370 MBq of (99m)Tc-tetrofosmin, at rest (30 patients) or with adenosine (21 patients), and to undergo an additional standard renal study with the glomerular tracer (99m)Tc-diethylenetriaminepentaacetic acid (DTPA) (74 MBq) after 1 wk (24 patients). Kidney images and renograms were obtained. Renal uptake index, expressed as the percentage ratio of kidney counts cumulated over the second minute after injection to the administered dose, was calculated as a functional renal parameter. Time to peak activity and separate kidney percentage uptake (as the percentage contribution of each kidney to total renal uptake) were also calculated.. Compared with (99m)Tc-DTPA, (99m)Tc-tetrofosmin provided better-quality kidney images, with a higher uptake index (13.17% +/- 4.76% vs. 8.33% +/- 2.45%, P < 0.001) and with comparable separate kidney percentage uptake and times to peak activity. (99m)Tc-tetrofosmin uptake index was significantly lower in the patients who were more compromised according to renal and cardiovascular functional parameters, and correlated with (99m)Tc-DTPA uptake index (r = 0.77, P < 0.001), serum creatinine (r = 0.59, P < 0.005), log brain natriuretic peptide N-terminal levels (r = -0.65, P < 0.005), myocardial and carotid intima-media wall thickness (for both, r = -0.61, P < 0.005), and the Doppler index of renal vascular resistance (r = -0.60, P < 0.005). In the 21 patients who underwent the provocative test, adenosine induced a significant decrease in renal (99m)Tc-tetrofosmin uptake index (from 14.12% +/- 4.50% to 11.81% +/- 3.33%, P < 0.005) suggesting a decrement in renal perfusion or function.. (99m)Tc-tetrofosmin cardiorenal scintigraphy is feasible at low cost as a single-shot study and may allow both the evaluation of renal morphology and renograms during a cardiac study and the calculation of renal functional parameters. Topics: Adenosine; Adult; Aged; Aged, 80 and over; Algorithms; Coronary Artery Disease; Female; Humans; Image Enhancement; Image Interpretation, Computer-Assisted; Infusions, Intravenous; Kidney Diseases; Male; Middle Aged; Organophosphorus Compounds; Organotechnetium Compounds; Radioisotope Renography; Radiopharmaceuticals; Reproducibility of Results; Rest; Sensitivity and Specificity; Vasodilator Agents | 2009 |
Illustrations of abdominal abnormalities on 99mTc tetrofosmin gated cardiac SPECT.
99mTc tetrofosmin is predominantly cleared by the hepatobiliary system and its scan is analogous to a cholescintigraphy. The radiopharmaceutical may be localized in the bone marrow. During cardiac acquisition, when the area being viewed includes the lower thorax and abdomen, abnormalities of the liver, gallbladder and kidneys, and the radioactivity in the oesophagus, stomach and bowel, as well as bone marrow uptake, can be depicted by routine raw data cine images. Excluding the intrathoracic abnormalities, these abdominal abnormalities are illustrated in this paper.. Retrospectively, we reviewed the raw data cine images from 566 patients. These images were 180 degrees or 360 degrees rotation and showed the abdominal organs and thoracic cage, including the ribs, sternum and spine. We found 234 abnormalities, which were correlated with radiography, laboratory and clinical findings.. Intra-abdominal abnormalities included bone marrow visualization, 93 occurrences (39.7%); duodeno-gastric (DG) and entero-gastric (EG) reflux, 47 (20.1%); non-visualization of the gallbladder, including possible causes of cholelithiasis, acute cholecystitis, or cholecystectomy, 31 (13.2%); elevation of the right diaphragm and depression of diaphragm, 30 (12.8%); renal abnormalities, including absent kidney, renal atrophy and cyst, 12 (5.1%); splenomegaly, 10 (4.3%); liver, including hepatomegaly and cirrhosis of the liver, eight (3.4%); and breast attenuation resulting in photopenia in the liver, three (1.2%).. (1) The bone marrow uptake of the vertebrae accounts for almost 40% of the abdominal abnormalities, and is usually concordant with anaemia; (2) DG and EG refluxes represent 20% of abdominal abnormalities; they may have a clinical impact and may or may not interfere with SPECT processes and result in artifacts of the inferior wall of the left ventricle; (3) non-visualization of the gallbladder should prompt a search for cholelithiasis; and (4) benign renal cyst or cirrhosis of the liver could also be demonstrated. These coincidental findings may be included in routine cardiac SPECT reports that may have clinical impact because they give the referring physician the chance to pursue further clinical investigation. Topics: Abdomen; Artifacts; Bone Marrow Diseases; Digestive System Diseases; Gated Blood-Pool Imaging; Heart; Humans; Incidental Findings; Kidney Diseases; Liver Diseases; Organophosphorus Compounds; Organotechnetium Compounds; Radiopharmaceuticals; Retrospective Studies; Tomography, Emission-Computed, Single-Photon; Viscera | 2005 |
Intrathoracic and intra-abdominal Tl-201 abnormalities seen on rotating raw cine data on dual radionuclide myocardial perfusion and gated SPECT.
The lower thorax and upper abdomen are visualized during cardiac acquisition of rest Tl-201 and stress Tc-99m tetrofosmin gated SPECT. Thus, abnormal Tl-201 localization in these areas and in organs such as parts of the lungs, liver, spleen, and kidneys can be observed, including rotating raw cine data.. Other than cardiac images, the authors retrospectively reviewed Tl-201 rotating (raw data) images of 235 patients. Abnormal findings in the lungs, liver, spleen, and kidneys were identified that correlated with the patients' clinical information; radiographic findings, including computed tomography and ultrasonography of the abdomen; other scintigraphic studies; and laboratory findings.. In 53 patients, 54 abnormalities were detected. Intrathoracic abnormalities included focal areas of increased uptake, one in the right lower lung and another in the right upper lung that confirmed lung cancer, in 2 patients; diffuse uptake in both lungs in 11 patients; photopenia in the lung bases, which had resulted from pleural effusions, in 3 patients; and abnormal right liver configuration caused by elevation of the right hemidiaphragm in 1 patient. Of the intra-abdominal abnormalities, 12 patients with splenomegaly were identified. Six patients had focal areas of increased uptake in the gastric area. Nonvisualization of one kidney resulted from a congenitally absent right kidney in 1 patient, from right nephrectomy in 1 patient, from end-stage renal disease in another, and from a lower position of the left or right kidneys in 5 patients. Small and decreased uptake of both kidneys resulted from end-stage renal disease in 1 patient. Small and decreased uptake of one kidney was noted in 1 patient with renal scarring, in 1 patient with a renal stone, in 3 patients with chronic pyelonephritis, and in 5 patients with renal cyst(s).. Discernible intrathoracic and intra-abdominal abnormalities using rotating raw cine data from imaging in three-dimensional displays include diffuse or focal pulmonary uptake, pleural effusion, elevation of a hemidiaphragm, splenomegaly, increased uptake in the gastric area, renal abnormalities including absent or small kidneys, end-stage renal disease, renal scarring, renal cyst(s), and lower position of a kidney. The incidental finding of such abnormalities may prompt further clinical investigation. Topics: Abdomen; Cardiovascular Diseases; Digestive System Diseases; Gated Blood-Pool Imaging; Humans; Kidney Diseases; Lung Diseases; Motion Pictures; Organophosphorus Compounds; Organotechnetium Compounds; Radiopharmaceuticals; Retrospective Studies; Sensitivity and Specificity; Thallium; Tomography, X-Ray Computed; Ultrasonography | 2002 |