technetium-tc-99m-sulfur-colloid and Vulvar-Neoplasms

technetium-tc-99m-sulfur-colloid has been researched along with Vulvar-Neoplasms* in 8 studies

Reviews

1 review(s) available for technetium-tc-99m-sulfur-colloid and Vulvar-Neoplasms

ArticleYear
Detection and credibility of sentinel node in vulvar cancer: a single institutional study and short review of literature.
    Archives of gynecology and obstetrics, 2011, Volume: 284, Issue:6

    To evaluate the detectability and credibility of sentinel lymph node (SLN) in vulvar cancer.. With Tc99m-nanocolloid and methylene blue, we identified SLNs in 34 patients. In 27 cases both tracers were used, while in 7 only blue dye was used. Completion lymphadenectomy was performed in all patients. SLNs and non-SLNs were sent separately for pathologic evaluation.. At least one SLN was identified in all patients. Detection rate per groin was not significantly higher in the combined versus blue dye only technique (42/50 vs. 10/14, p = 0.43). 99m-Tc was not superior to blue dye in detecting SLN (42/50 vs. 50/64, p = 0.65). Midline location of the tumor did not seem to negatively affect the procedure. Four false negatives were observed in three patients with tumors >4 cm. Negative predictive value of SLN was 100% for grade I tumors ≤ 4 cm in patients ≤ 71 years.. Tc-99m does not seem to be superior to methylene blue in the detection of SLN in vulvar cancer. Patients of younger age with small, well-differentiated tumors appear to be the most suitable candidates for lymphatic mapping.

    Topics: Adult; Aged; Aged, 80 and over; Female; Humans; Lymph Node Excision; Lymph Nodes; Lymphatic Metastasis; Methylene Blue; Middle Aged; Predictive Value of Tests; Radionuclide Imaging; Sentinel Lymph Node Biopsy; Technetium Tc 99m Sulfur Colloid; Vulvar Neoplasms

2011

Trials

2 trial(s) available for technetium-tc-99m-sulfur-colloid and Vulvar-Neoplasms

ArticleYear
A prospective study of sentinel lymph node detection in vulval carcinoma: is it time for a change in clinical practice?
    International journal of gynecological cancer : official journal of the International Gynecological Cancer Society, 2011, Volume: 21, Issue:3

    To determine the accuracy of sentinel lymph node (SLN) detection in vulval carcinoma and to report the reliability and safety of this procedure.. For a period of 6 years, we recruited women undergoing surgery for vulval carcinoma. All women had a preoperative biopsy confirming the depth of invasion greater than 1 mm. Sentinel lymph node detection was performed using the combined method (Tc-99m and methylene-blue dye). The standard management included complete inguinofemoral lymphadenectomy. When inguinofemoral lymph nodes were found grossly to be enlarged, these nodes were debulked, and the women subsequently treated with radiotherapy with or without chemotherapy. During the last 2 years of the study, a selected group of women had an SLN dissection alone. The SLNs were ultrastaged when they were negative on routine hematoxylin and eosin examination.. Among 60 women undergoing SLN detection, SLN was detected in 59 women (98.3%) with combined method. Blue dye did not detect an SLN in 3 women resulting in a 93.3% detection rate. The median SLN count was 2 nodes (range, 1-9). Of the 60 women, 41 had inguinofemoral lymphadenectomy, 4 had only enlarged inguinofemoral nodes debulked, and 15 had the SLN only removed. The non-SLN count was 9 nodes (range, 3-17). There were no false-negative SLNs. Twenty-one women (35%) had positive nodes on final histology. Ultrastaging increased detection of metastases in 6.9% of nodes relative to routine hematoxylin and eosin examination and upstaged 12% of women. The median follow-up was 24 months (range, 2-66 months).. Sentinel lymph node detection is safe and accurate in assessing lymph node status in women with vulval cancer undergoing staging. The combined method using Tc-99m and methylene blue dye injection for SLN detection has the best detection rate. Routine ultrastaging of negative SLN improves the detection of nodal metastases.

    Topics: Adult; Aged; Aged, 80 and over; Carcinoma, Squamous Cell; Female; Humans; Lymph Node Excision; Lymphatic Metastasis; Methylene Blue; Middle Aged; Neoplasm Staging; Practice Patterns, Physicians'; Prospective Studies; Radiopharmaceuticals; Sentinel Lymph Node Biopsy; Survival Rate; Technetium Tc 99m Sulfur Colloid; Treatment Outcome; Vulvar Neoplasms

2011
Isolated sentinel lymph node dissection with conservative management in patients with squamous cell carcinoma of the vulva: a prospective trial.
    Gynecologic oncology, 2008, Volume: 109, Issue:1

    Sentinel lymph node (SLN) dissections have a high sensitivity and negative predictive value for the detection of metastatic disease. The objective of this study was to examine the inguinal recurrence rate along with complication rates for patients undergoing inguinal SLN dissection alone for vulvar carcinoma.. An IRB approved prospective study enrolled patients with biopsy proven squamous cell carcinoma of the vulva. Peritumoral injection of Tc-99 sulfur colloid and methylene blue dye was used to identify SLNs intraoperatively. Patients with SLNs negative for metastatic disease were followed clinically. Patients with metastasis detected in a SLN subsequently underwent a full groin node dissection followed by standard treatment protocols.. Thirty-six patients were enrolled onto study with 35 undergoing a SLN dissection. All SNL dissections were successful with a mean of 2 SLN obtained per groin. There were 24 patients with stage I disease, 8 stage II, 3 stage III and 1 stage IV. A total of 56 SLN dissections were performed with 4 patients found to have inguinal metastasis by SLN dissection. There were 31 patients with a total of 46 SLN dissections found to be negative for metastatic disease. The median follow-up has been 29 months (range 8 to 51) with 2 groin recurrences for a groin recurrence rate of 4.3% and a recurrence rate per patient of 6.4%. There have been no reports of groin breakdown, extremity cellulitis or lymphedema.. The recurrence rate for patients undergoing inguinal sentinel node dissection alone is low. These patients did not experience any complications as seen with complete groin node dissections. Sentinel lymph node dissection should be considered as an option for evaluation of inguinal nodes for metastatic disease.

    Topics: Adult; Aged; Aged, 80 and over; Carcinoma, Squamous Cell; Cellulitis; Female; Humans; Lymph Node Excision; Lymph Nodes; Lymphatic Metastasis; Lymphedema; Methylene Blue; Middle Aged; Neoplasm Recurrence, Local; Neoplasm Staging; Prospective Studies; Radionuclide Imaging; Sentinel Lymph Node Biopsy; Technetium Tc 99m Sulfur Colloid; Vulvar Neoplasms

2008

Other Studies

5 other study(ies) available for technetium-tc-99m-sulfur-colloid and Vulvar-Neoplasms

ArticleYear
Metastatic and non-metastatic sentinel inguinofemoral lymph nodes in vulvar cancer show an increased lymphangiogenesis.
    Annals of agricultural and environmental medicine : AAEM, 2020, Mar-17, Volume: 27, Issue:1

    Lymph node involvement is a strong predictor of disease recurrence and patient survival in vulvar cancer. The aim of the study was to evaluate the feasibility of sentinel lymph node (SLN) screening, the incidence of skip metastases, and lymph node lymphangiogenesis.. Fifty-five patients participated in this prospective, single centre study. A double SLN screening method was employed using radiocolloid (technetium-99 sulfur colloid) and 1.0% Isosulfan Blue. Immunohistochemistry, using a mouse monoclonal antibody against D2-40, was used to evaluate lymphatic vessel density (LVD). All calculations were performed using STATISTICA software v. 10 (StatSoft, USA, 2011); p < 0.05 was considered significant.. Using both methods of SLN detection, 100% accuracy was achieved, and skip metastases were diagnosed in only one woman (1.82%). Peri-tumour median LVD was significantly increased compared with matched intra-tumour samples (p < 0.001), while median LVD was significantly lower in negative, compared with positive SLN, regardless of whether matched non-SLN were negative (p < 0.001) or positive (p = 0.005). Metastatic SLN exhibited significantly higher median LVD compared with matched negative non-SLN (p = 0.015), while no significant difference in median LVD was detected between positive SLN and matched positive non-SLN. However, negative SLN had a significantly higher median LVD compared with matched negative non-SLN (p = 0.012).. SLN detection is a safe and feasible procedure in vulvar cancer. In patients without nodular involvement, SLN, compared with non-SLN, exhibited significantly higher median LVD, which may be an indication of its preparation to host metastases, and thus requires further investigation.

    Topics: Aged; Animals; Antibodies, Monoclonal, Murine-Derived; Carcinoma, Squamous Cell; Female; Groin; Humans; Immunohistochemistry; Lymphangiogenesis; Lymphatic Metastasis; Mice; Neoplasm Staging; Prospective Studies; Rosaniline Dyes; Sentinel Lymph Node; Technetium Tc 99m Sulfur Colloid; Vulvar Neoplasms

2020
[Feasibility and morbidity of sentinel lymph node detection in patients with vulvar carcinoma].
    Bulletin du cancer, 2005, May-01, Volume: 92, Issue:5

    The aim of this study was to investigate the feasibility and the morbidity of sentinel lymph node detection in patients with vulvar carcinoma. In 15 patients with vulvar squamous cell carcinoma, the inguinal sentinel lymph nodes was detected using both peritumoral injection of technetium-99m sulfur colloid and isosuflan blue before the surgical time. The detection of the inguinal sentinel lymph node was never completed by an inguinal lymphadenectomy. In case of metastatic lymph node, patients were treated by complementary inguinal irradiation. A total of 19 inguinal node dissection were performed. The sentinel lymph node was identified in 18/19 (94.7%) groin dissections. A total of 38 sentinel lymph nodes were removed. 4 patients were found to have metastatic lymph node (26.7%) with a total of 6 metastatic lymph nodes. The postoperative morbidity was minimal, with only one patient presenting a permanent edema of the extremity (6.7%) after complementary inguinal irradiation. We confirm the results of previous studies that sentinel node dissection appears to be technically feasible in patients with vulvar carcinoma. This may reduce the morbidity of usual inguinal lymphadenectomy without under-evaluate the nodal status. This procedure could be implemented in future therapy concepts.

    Topics: Carcinoma, Squamous Cell; Feasibility Studies; Female; Humans; Inguinal Canal; Lymph Node Excision; Radionuclide Imaging; Radiopharmaceuticals; Technetium Tc 99m Sulfur Colloid; Vulvar Neoplasms

2005
Sentinel node identification and the ability to detect metastatic tumor to inguinal lymph nodes in squamous cell cancer of the vulva.
    Gynecologic oncology, 2003, Volume: 89, Issue:3

    The goal of this study was to identify one or more inguinal sentinel nodes in patients with primary squamous cell carcinoma of the vulva and to determine the ability of the sentinel node to predict metastasis to the inguinal lymphatic basin.. Techniques employing technetium-99m (Tc-99m) sulfur colloid and isosulfan blue dye were utilized to identify sentinel nodes in the inguinal lymphatic beds. Technetium-99m sulfur colloid was injected intradermally at the tumor margins 90-180 min preoperatively followed by a similar injection of isosulfan blue dye 5-10 min before the groin dissection. A handheld collimated gamma counter was employed to identify Tc-99m-labeled sentinel nodes. Lymphatic tracts that had taken up blue dye and their corresponding sentinel node were also identified and retrieved. A completion inguinal dissection was then performed. Each sentinel node was labeled as hot and blue, hot and nonblue, or cold and blue. The sentinel nodes were subjected to pathologic examination with step sections and nonsentinel nodes were evaluated in the standard fashion.. Twenty-one patients with a median age of 79 were entered onto protocol and a total of 31 inguinal node dissections were performed. A sentinel node was identified in 31/31 (100%) groin dissections with the use of Tc-99m. Isosulfan blue dye identified a sentinel node in 19/31 (61%) groin dissections. Surgical staging revealed 7 patients with stage I disease, 5 with stage II disease, 5 with stage III disease, and 4 with stage IV disease. Lymph nodes in 9 groin dissections were found to have metastatic disease, and in 4 of these dissections, the sentinel node was the only positive node. Lymph nodes in 22 groin dissections had no evidence of metastasis. No false-negative sentinel lymph nodes were obtained (sentinel node negative and a nonsentinel node positive).. Tc-99m sulfur colloid is superior to isosulfan blue dye in the detection of sentinel nodes in inguinal dissections of patients with vulvar cancer. A sentinel node dissection utilizing Tc-99m alone can identify a sentinel node in all inguinal dissections. Pathologic examination with step sections has shown the sentinel node to be an accurate predictor of metastatic disease to the inguinal nodal chain.

    Topics: Carcinoma, Squamous Cell; Female; Humans; Inguinal Canal; Lymphatic Metastasis; Predictive Value of Tests; Radionuclide Imaging; Radiopharmaceuticals; Rosaniline Dyes; Sentinel Lymph Node Biopsy; Technetium Tc 99m Sulfur Colloid; Vulvar Neoplasms

2003
Sentinel lymph node procedure in early vulvar cancer.
    Gynecologic oncology, 2003, Volume: 90, Issue:2

    Topics: Female; Humans; Lymph Nodes; Radionuclide Imaging; Radiopharmaceuticals; Sentinel Lymph Node Biopsy; Technetium Tc 99m Sulfur Colloid; Vulvar Neoplasms

2003
A pilot study utilizing intraoperative lymphoscintigraphy for identification of the sentinel lymph nodes in vulvar cancer.
    Gynecologic oncology, 1997, Volume: 66, Issue:3

    To identify sentinel lymph nodes using intraoperative lymphoscintigraphy.. Technetium-99-labeled sulfur colloid was injected at the site of primary vulvar carcinoma. An intraoperative gamma counter was used to identify one or more sentinel lymph nodes.. Ten patients underwent bilateral inguinal and femoral lymphadenectomy. The clinical stages are as follows: T1 in 6, T2 in 2, and T3 in 2. A total of four groins (3 patients) were positive for metastases. In one patient only the sentinel node was positive for disease. In a second patient, two unilateral nodes were positive for disease and both were identified with the gamma counter as sentinel nodes. In the third patient, a single sentinel node was positive for malignancy in each groin. Multiple nonsentinel lymph nodes were positive in each groin in this patient. In no case was the sentinel node negative when other nonsentinel nodes were positive.. Intraoperative lymphoscintigraphy quantitatively identifies one or more sentinel lymph nodes. Since sentinel lymph nodes can be localized transcutaneously, this technique may be useful for selective lymphadenectomy. Larger patient accrual is necessary to verify this technique.

    Topics: Female; Humans; Lymph Node Excision; Lymphatic Metastasis; Monitoring, Intraoperative; Pilot Projects; Radionuclide Imaging; Radiopharmaceuticals; Technetium Tc 99m Sulfur Colloid; Vulvar Neoplasms

1997