Page last updated: 2024-08-16

technetium tc 99m sestamibi and Abnormality, Heart

technetium tc 99m sestamibi has been researched along with Abnormality, Heart in 8 studies

Research

Studies (8)

TimeframeStudies, this research(%)All Research%
pre-19900 (0.00)18.7374
1990's3 (37.50)18.2507
2000's3 (37.50)29.6817
2010's2 (25.00)24.3611
2020's0 (0.00)2.80

Authors

AuthorsStudies
Gao, XJ; He, ZX; Kang, LM; Li, Y; Lu, MJ; Luo, XL; Wan, JY; Yang, MF; Yang, YJ; Zhang, J; Zhao, SH1
Gidding, SS; Goudie, B; Remmert, J; Robinson, B1
Eguchi, M; Hashimoto, A; Kyuma, M; Nakahara, N; Nakata, T; Shimamoto, K; Shimoshige, S; Takahashi, T; Tsuchihashi, K; Uno, K; Wakabayashi, T1
Burger, P; Müller-Brand, J; Pfisterer, M; Walter, MA; Zellweger, M1
Celentano, L; Cuocolo, A; Imbriaco, M; Nappi, A; Nicolai, E; Pace, L; Palma, G; Vosa, C1
Hisida, K; Nakajima, K; Taki, J; Taniguchi, M; Tonami, N1
Ferency, SL; Fisher, DJ; McCloskey, JP; Rosenbaum, DM1
Doğruca, Z; Kabasakal, L; Nisil, C; Onsel, Q; Vural, VA; Yapar, F1

Trials

2 trial(s) available for technetium tc 99m sestamibi and Abnormality, Heart

ArticleYear
Quantitative assessment of right ventricular structural abnormalities by right ventricular polar mapping of single photon emission computed tomogram.
    Nuclear medicine communications, 2002, Volume: 23, Issue:10

    Topics: Adolescent; Adult; Aged; Child; Electrocardiography; Female; Heart Defects, Congenital; Heart Ventricles; Humans; Male; Middle Aged; Radiopharmaceuticals; Stroke Volume; Technetium Tc 99m Sestamibi; Tomography, Emission-Computed, Single-Photon; Ventricular Dysfunction, Right; Ventricular Function, Right

2002
A comparison of Tl-201 stress-reinjection-prone SPECT and Tc-99m-sestamibi gated SPECT in the differentiation of inferior wall defects from artifacts.
    Nuclear medicine communications, 2000, Volume: 21, Issue:8

    Topics: Artifacts; Electrocardiography; Exercise Test; False Positive Reactions; Female; Gated Blood-Pool Imaging; Heart; Heart Defects, Congenital; Humans; Male; Middle Aged; Prone Position; Radiopharmaceuticals; Supine Position; Technetium Tc 99m Sestamibi; Thallium Radioisotopes; Tomography, Emission-Computed, Single-Photon

2000

Other Studies

6 other study(ies) available for technetium tc 99m sestamibi and Abnormality, Heart

ArticleYear
Abnormalities of myocardial perfusion and glucose metabolism in patients with isolated left ventricular non-compaction.
    Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2014, Volume: 21, Issue:3

    Topics: Adolescent; Adult; Aged; Aged, 80 and over; Coronary Artery Disease; Female; Fluorodeoxyglucose F18; Heart Defects, Congenital; Humans; Hyperglycemia; Male; Middle Aged; Positron-Emission Tomography; Radiopharmaceuticals; Reproducibility of Results; Sensitivity and Specificity; Stroke Volume; Technetium Tc 99m Sestamibi; Tomography, Emission-Computed, Single-Photon; Young Adult

2014
Usefulness of myocardial perfusion imaging with exercise testing in children.
    Pediatric cardiology, 2012, Volume: 33, Issue:7

    Topics: Adolescent; Chest Pain; Exercise Test; Female; Heart Defects, Congenital; Humans; Male; Myocardial Perfusion Imaging; Radiopharmaceuticals; Retrospective Studies; Technetium Tc 99m Sestamibi

2012
Situs inversus completus.
    European journal of nuclear medicine and molecular imaging, 2003, Volume: 30, Issue:8

    Topics: Coronary Vessel Anomalies; Coronary Vessels; Diagnosis, Differential; Diagnostic Errors; Heart; Heart Defects, Congenital; Humans; Medical Errors; Radionuclide Imaging; Radiopharmaceuticals; Situs Inversus; Technetium Tc 99m Sestamibi

2003
Technetium-99m methoxy isobutyl isonitrile simultaneous evaluation of ventricular function and myocardial perfusion in patients with congenital heart disease.
    Clinical nuclear medicine, 1994, Volume: 19, Issue:1

    Topics: Child, Preschool; Evaluation Studies as Topic; Female; Gated Blood-Pool Imaging; Heart; Heart Defects, Congenital; Humans; Male; Technetium Tc 99m Sestamibi; Ventricular Function, Left

1994
Comparison of 99Tcm-sestamibi and 201Tl-chloride to estimate right ventricular overload in children.
    Nuclear medicine communications, 1995, Volume: 16, Issue:11

    Topics: Child, Preschool; Female; Heart Defects, Congenital; Humans; Hypertrophy, Right Ventricular; Male; Radionuclide Imaging; Technetium Tc 99m Sestamibi; Thallium Radioisotopes; Ventricular Function, Left; Ventricular Function, Right

1995
Pulmonary atresia with intact septum. Findings on exercise stress sestamibi scan.
    Clinical nuclear medicine, 1997, Volume: 22, Issue:8

    Topics: Adolescent; Exercise Test; Heart Defects, Congenital; Humans; Male; Pulmonary Atresia; Radionuclide Imaging; Radiopharmaceuticals; Technetium Tc 99m Sestamibi

1997