technetium-tc-99m-exametazime has been researched along with Aneurysm--False* in 3 studies
3 other study(ies) available for technetium-tc-99m-exametazime and Aneurysm--False
Article | Year |
---|---|
Pseudoaneurysm and coronary abscess secondary to coronary stent fracture identified with Tc-99m hexamethylpropyleneamine oxime-labeled white blood cell SPECT/CT scintigraphy.
Topics: Abscess; Aged; Aneurysm, False; Coronary Vessels; Humans; Leukocytes; Male; Prosthesis Failure; Stents; Technetium Tc 99m Exametazime; Tomography, Emission-Computed, Single-Photon; Tomography, X-Ray Computed | 2011 |
[Intense uptake of 99mTc HMPAO leukocytes in a patient with a non-infected pseudoaneurysm of the left femoral artery].
Topics: Aged; Aneurysm, False; Aortic Aneurysm, Abdominal; Arteritis; Blood Vessel Prosthesis; Diagnosis, Differential; Erythrocytes; Femoral Artery; Humans; Iliac Artery; Leukocytes; Male; Postoperative Complications; Radionuclide Imaging; Radiopharmaceuticals; Technetium Tc 99m Exametazime | 1999 |
Diagnosis of prosthetic vascular graft infection by technetium-99m-HMPAO-labeled leukocytes.
The purpose of this study was to determine the usefulness of 99mTc-HMPAO-labeled leukocyte scans in the diagnosis of prosthetic vascular graft infection.. We performed 75 scans in 61 patients with vascular grafts. Thirty-six patients were evaluated for suspected infection and 25 were control patients. Scintigraphic images were performed at 5 min, 30 min, 3 hr and, occasionally, 24 hr. Persistent increased uptake at 3 hr along the suspected area of the graft was considered evidence of graft infection.. All 20 infected grafts were detected with 99mTc-HMPAO leukocyte scan. The sensitivity and specificity of the scan in the detection of infected graft were 100%. We also detected two pelvic abscesses, two infected fistulae, two soft-tissue infections, three cases of ischemic colitis, one acute diverticulitis, one infected hematoma, one septic arthritis and one noninfected hematoma. One patient with a superficial groin infection had a negative scan. The eight pseudoaneurysms did not show scintigraphic evidence of graft infection. Correlative CT studies were performed in 12 cases.. Technetium-99m-HMPAO-labeled leukocyte scan is an accurate and valuable diagnostic method for evaluation of suspected prosthetic vascular graft infection. Topics: Aged; Aneurysm, False; Aorta, Abdominal; Blood Vessel Prosthesis; Female; Femoral Artery; Humans; Leukocytes; Male; Organotechnetium Compounds; Oximes; Prosthesis-Related Infections; Radionuclide Imaging; Sensitivity and Specificity; Technetium Tc 99m Exametazime; Time Factors | 1994 |