technetium-tc-99m-bicisate and Sleep-Apnea-Syndromes

technetium-tc-99m-bicisate has been researched along with Sleep-Apnea-Syndromes* in 1 studies

Other Studies

1 other study(ies) available for technetium-tc-99m-bicisate and Sleep-Apnea-Syndromes

ArticleYear
Improvement of brain SPECT by stabilization of Tc-99m-HMPAO with methylene blue or cobalt chloride. Comparison with Tc-99m-ECD.
    Nuklearmedizin. Nuclear medicine, 1999, Volume: 38, Issue:3

    This present study was carried out to investigate whether stabilization of Tc-99m-HMPAO with methylene blue (MB) or cobalt chloride (CC) causes a sensible improvement in image quality and how cerebral to noncerebral activity ratios compare with those of Tc-99m-ECD.. 30 minutes after preparation 400-600 MBq unstabilized Tc-99m-HMPAO (N = 35 patients), Tc-99m-HMPAO added with MB (N = 24 patients), added with CC (N = 30 patients) or Tc-99m-ECD (N = 28 patients) were injected. Radiochemical stability was measured in vitro with three chromatographical methods. Image quality was assessed quantitatively using two ratios, one of them determined by count densities of brain/scalp (Os), the other one by count densities of brain/nose (QN). In addition, image quality (0 = bad, 3 = excellent) and background activity (0 = high, 3 = no) were visually assessed by three independent observers.. In contrast to unstabilized Tc-99m-HMPAO the integrity of the complexes of MB-Tc-99m-HMPAO, CC-Tc-99m-HMPAO and Tc-99m-ECD decreased only by a few percent during a period of 2 hours after reconstitution (66.8 +/- 9.9 vs. 93.0 +/- 2.5, 91.8 +/- 1.9 and 96.9 +/- 1.4%, p < 0.001). Qs and Qn (m.v. +/- SD) differed significantly between studies using unstabilized Tc-99m-HMPAO (3.0 +/- 0.4 and 2.1 +/- 0.3), MB-Tc-99m-HMPAO (3.4 +/- 0.4 and 2.3 +/- 0.3), CC-Tc-99m-HMPAO (3.6 +/- 0.6 and 2.6 +/- 0.4) and those using Tc-99m-ECD (4.3 +/- 0.7 and 4.8 +/- 1.4, p < 0.05 and < 0.001). Stabilization with CC or MB resulted in significant higher scoring of image quality and lower scoring of background activity in comparison to that of unstabilized Tc-99m-HMPAO, without reaching the scores obtained with Tc-99m-ECD.. It is concluded that stabilization of Tc-99m-HMPAO with MB or CC definitely improves image quality in rCBF-SPECT, without reaching that of Tc-99m-ECD. Improvement of image quality results from the reduction of the amount of decomposition products that contribute to considerable extracerebral activity.

    Topics: Adult; Aged; Aged, 80 and over; Brain; Cerebrovascular Disorders; Cobalt; Cysteine; Depression; Drug Stability; Female; Humans; Male; Methylene Blue; Middle Aged; Neurodegenerative Diseases; Organotechnetium Compounds; Radiopharmaceuticals; Scalp; Sensitivity and Specificity; Sleep Apnea Syndromes; Technetium Tc 99m Exametazime; Tomography, Emission-Computed, Single-Photon

1999