technetium-tc-99m-bicisate and Kidney-Failure--Chronic

technetium-tc-99m-bicisate has been researched along with Kidney-Failure--Chronic* in 2 studies

Trials

1 trial(s) available for technetium-tc-99m-bicisate and Kidney-Failure--Chronic

ArticleYear
Effect of dialysis on cerebral blood flow in depressive end-stage renal disease patients.
    Annals of nuclear medicine, 2011, Volume: 25, Issue:3

    The aim of this study was to investigate regional cerebral blood flow (rCBF) changes of end-stage renal disease (ESRD) patients with depressive symptoms during dialysis.. Fourteen patients with ESRD underwent Tc-99m ethylcysteinate dimer (Tc-99m ECD) brain single photon emission computed tomography (SPECT) and were evaluated the severity of depressive mood at pre-dialytic period and at least 6 months after dialysis initiation. rCBF was analyzed using statistical parametric mapping (SPM) in brain SPECT image. The responder was defined as a decrease of ≥25% in Hamilton Depression Rating Scale (HDRS) score from baseline HDRS score.. Pre-dialysis brain SPECT did not show any rCBF differences between responders and non-responders. The follow-up brain SPECT revealed a significant higher perfusion in left middle temporal gyrus of responder group when compared with non-responder (hemisphere coordinate X, Y, Z; -58, -2, -16, peak Z = 3.36, p = 0.046). In responder, a significant increase in rCBF was found in right parahippocampal gyrus (hemisphere coordinate X, Y, Z; 30, -40, -14, peak Z = 3.51, p = 0.043). In non-responder, there were significant decreases in rCBF in left superior frontal gyrus (hemisphere coordinate X, Y, Z; -22, 30, 42, peak Z = 3.86, p = 0.032) and right orbitofrontal cortex (hemisphere coordinate X, Y, Z; 10, 58, -6, peak Z = 3.81, p = 0.046).. The present findings showed the characteristic patterns of rCBF changes in depressive ESRD patients having maintenance dialysis. Further investigations in brain blood flow and glucose metabolism are needed to elucidate the effect of dialysis itself and the difference of according to dialysis modality in patients having depression and ESRD.

    Topics: Adult; Aged; Brain; Cerebrovascular Circulation; Cysteine; Depressive Disorder; Dimerization; Female; Humans; Kidney Failure, Chronic; Male; Middle Aged; Organotechnetium Compounds; Renal Dialysis; Tomography, Emission-Computed, Single-Photon; Treatment Outcome

2011

Other Studies

1 other study(ies) available for technetium-tc-99m-bicisate and Kidney-Failure--Chronic

ArticleYear
Clinical evaluation of technetium-99m-L,L-ethylenedicysteine in patients with chronic renal failure.
    Journal of nuclear medicine : official publication, Society of Nuclear Medicine, 1997, Volume: 38, Issue:5

    Technetium-99m-L,L-ethylenedicysteine (99mTc-L,L-EC), a new renal radiopharmaceutical, has been shown to have similar excretion characteristics but a higher plasma clearance than 99mTc-mercaptoacetyltriglycine (99mTc-MAG3) in normal volunteers and patients with obstructive nephropathy. This study evaluated 99mTc-L,L-EC in patients with chronic renal failure.. The clearance of 99mTc-L,L-EC was compared with that of 125l-hippuran in 26 patients with varying degrees of chronic renal impairment (serum creatine 168-1163 mumol/liter). All 26 patients also were imaged with 99mTc-L,L-EC (70-80 MBq). Fifteen patients had further imaging with 99mTc-MAG3 (100 MBq) the following day.. A subjective analysis of the 99mTc-L,L-EC images revealed that all were of acceptable quality regardless of creatinine level. In the 15 patients who were imaged with both 99mTc-L,L-EC and 99mTc-MAG3, general image quality and target-to-background ratios were similar. Time-activity curves and mean parenchymal transit times obtained with the two agents were almost identical. Plasma clearance values (mean +/- s.d.) of 99mTc-L,L-EC and 125l-hippuran were 81 +/- 68 ml/min and 114 +/- 104 ml/min, respectively. Mean 99mTc-L,L-EC clearance was 71% of the mean 125l-hippuran value.. Technetium-99m-L,L-EC provides equally high-quality images to 99mTc-MAG3 in patients with chronic renal failure. Technetium-99m-L,L-EC clearance more closely resembles that of hippuran than does 99mTc-MAG3 clearance. These features together with its ease of preparation make 99mTc-L,L-EC an attractive alternative to 99mTc-MAG3 in patients with chronic renal failure.

    Topics: Contrast Media; Cysteine; Evaluation Studies as Topic; Female; Humans; Iodine Radioisotopes; Iodohippuric Acid; Kidney Failure, Chronic; Male; Middle Aged; Organotechnetium Compounds; Radioisotope Renography; Technetium Tc 99m Mertiatide

1997