Page last updated: 2024-08-22

tantalum and Blood Clot

tantalum has been researched along with Blood Clot in 15 studies

Research

Studies (15)

TimeframeStudies, this research(%)All Research%
pre-19904 (26.67)18.7374
1990's9 (60.00)18.2507
2000's1 (6.67)29.6817
2010's1 (6.67)24.3611
2020's0 (0.00)2.80

Authors

AuthorsStudies
Albuquerque, FC; Chen, T; Ducruet, AF; Kalani, MY; McDougall, CG1
Beythien, C; Hamm, CW; Langer, A; Reifart, N; Sievert, H; Terres, W; Utech, A1
Antonius, J; Bianchi, S; Duran, CG; Gallo, R; Mimish, L; Ribeiro, PA; Sriram, R1
Betz, E; Bruck, B; Claussen, CD; Duda, SH; Hagmeier, S; Hanke, H; Schmahl, FW; Schott, U; Schulze, S; Tepe, G1
Cearlock, J; Fontaine, AB; Hoffman, R; Koelling, K; Passos, SD; Spigos, DG1
Bau, J; Beythien, C; Gutensohn, K; Kühnl, P; Meinertz, T1
Bau, J; Beythien, C; Gutensohn, K; Kuehnl, P; Meinertz, T1
Boos, IB; Göttmann, D; Strecker, EP1
Aroney, CN; Bett, JH; Cameron, J; Cannon, A; Dooris, M; Garrahy, PJ; McEniery, PT; Ponde, CK; Watson, PS1
Crijns, HJ; de Kam, PJ; Monnink, SH; Peels, HO; Tigchelaar, I; van Boven, AJ; van Oeveren, W1
Chen, JY; Chu, PK; Huang, N; Leng, YX; Tian, XB; Wang, LP; Yang, P1
Markov, I1
Baier, RE; DePalma, VA; Ford, JW; Furuse, A; Glott, VL1
Badura, R; Kuprowski, M; Modrakowski, A; Orlowski, T2

Trials

1 trial(s) available for tantalum and Blood Clot

ArticleYear
Multicenter evaluation of the Strecker tantalum stent for acute coronary occlusion after angioplasty.
    American heart journal, 1995, Volume: 129, Issue:3

    Topics: Angioplasty, Balloon, Coronary; Anticoagulants; Coronary Angiography; Coronary Disease; Female; Follow-Up Studies; Graft Occlusion, Vascular; Hospital Mortality; Humans; Male; Middle Aged; Recurrence; Stents; Tantalum; Thrombosis; Treatment Outcome

1995

Other Studies

14 other study(ies) available for tantalum and Blood Clot

ArticleYear
Development of syndrome of inappropriate antidiuretic hormone secretion (SIADH) after Onyx embolisation of a cavernous carotid fistula.
    BMJ case reports, 2016, Mar-21, Volume: 2016

    Topics: Carotid-Cavernous Sinus Fistula; Drug Combinations; Embolization, Therapeutic; Female; Follow-Up Studies; Humans; Inappropriate ADH Syndrome; Middle Aged; Pituitary Gland; Polyvinyls; Tantalum; Thrombosis

2016
A new expandable intracoronary tantalum (Strecker) stent: early experimental results and follow-up to twelve months.
    American heart journal, 1993, Volume: 125, Issue:2 Pt 1

    Topics: Animals; Balloon Occlusion; Catheterization; Coronary Disease; Equipment Design; Feasibility Studies; Follow-Up Studies; Sheep; Stents; Tantalum; Thrombosis; Vascular Patency

1993
Covered stents for prevention of restenosis. Experimental and clinical results with different stent designs.
    Investigative radiology, 1996, Volume: 31, Issue:4

    Topics: Aged; Alloys; Animals; Aorta, Abdominal; Aortic Diseases; Arteriosclerosis; Biocompatible Materials; Constriction, Pathologic; Equipment Design; Female; Femoral Artery; Humans; Iliac Artery; Male; Polyethylene Terephthalates; Polymethacrylic Acids; Rabbits; Recurrence; Stents; Tantalum; Thrombosis

1996
Polymeric surface modifications of tantalum stents.
    Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery, 1996, Volume: 3, Issue:3

    Topics: Animals; Arteriovenous Shunt, Surgical; Biocompatible Materials; Blood Platelets; Graft Occlusion, Vascular; Indium Radioisotopes; Microscopy, Electron; Platelet Adhesiveness; Polymers; Polyurethanes; Stents; Surface Properties; Swine; Tantalum; Thrombosis; Time Factors; Xylenes

1996
Tantalum stents induce expression of GMP140 and GP53 on platelets after contact in an in vitro model.
    Beitrage zur Infusionstherapie und Transfusionsmedizin = Contributions to infusion therapy and transfusion medicine, 1996, Volume: 33

    Topics: Angioplasty, Balloon, Coronary; Antigens, Human Platelet; Blood Platelets; Flow Cytometry; Humans; Risk Factors; Stents; Tantalum; Thrombosis

1996
Flow cytometric analysis of coronary stent-induced alterations of platelet antigens in an in vitro model.
    Thrombosis research, 1997, Apr-01, Volume: 86, Issue:1

    Topics: Adult; Antigens; Antigens, CD; Blood Platelets; Coronary Vessels; Female; Flow Cytometry; Humans; In Vitro Techniques; Male; P-Selectin; Platelet Activation; Platelet Glycoprotein GPIb-IX Complex; Platelet Glycoprotein GPIIb-IIIa Complex; Platelet Membrane Glycoproteins; Stents; Tantalum; Tetraspanin 30; Thrombosis

1997
Femoropopliteal artery stent placement: evaluation of long-term success.
    Radiology, 1997, Volume: 205, Issue:2

    Topics: Adult; Aged; Aged, 80 and over; Angioplasty, Balloon; Arterial Occlusive Diseases; Equipment Failure; Female; Femoral Artery; Follow-Up Studies; Humans; Male; Middle Aged; Multivariate Analysis; Popliteal Artery; Prospective Studies; Radiography; Risk Factors; Stents; Tantalum; Thrombosis; Treatment Failure; Vascular Patency

1997
Angiographic follow-up and clinical experience with the flexible Tantalum Cordis stent.
    Catheterization and cardiovascular diagnosis, 1998, Volume: 43, Issue:2

    Topics: Angina Pectoris; Coronary Angiography; Coronary Vessels; Equipment Design; Female; Follow-Up Studies; Humans; Male; Middle Aged; Myocardial Infarction; Stents; Tantalum; Thrombosis

1998
Silicon-carbide coated coronary stents have low platelet and leukocyte adhesion during platelet activation.
    Journal of investigative medicine : the official publication of the American Federation for Clinical Research, 1999, Volume: 47, Issue:6

    Topics: Blood Platelets; Carbon Compounds, Inorganic; Cell Adhesion; Coated Materials, Biocompatible; Coronary Vessels; Humans; In Vitro Techniques; Indomethacin; Leukocytes; Platelet Activation; Prosthesis Design; Silicon Compounds; Stainless Steel; Stents; Tantalum; Thrombosis

1999
Antithrombogenic investigation of surface energy and optical bandgap and hemocompatibility mechanism of Ti(Ta(+5))O2 thin films.
    Biomaterials, 2002, Volume: 23, Issue:12

    Topics: Animals; Biocompatible Materials; Blood; Blood Platelets; Dogs; Fibrinogen; Mathematics; Rabbits; Solvents; Surface Properties; Tantalum; Thrombosis; Titanium

2002
[Replacement of heart valves with mechanical prostheses (literature survey)].
    Khirurgiia, 1974, Volume: 27, Issue:5

    Topics: Animals; Aortic Valve; Heart Valve Prosthesis; Humans; Mitral Valve; Polymers; Polytetrafluoroethylene; Tantalum; Thrombosis

1974
Investigation of three-surface properties of several metals and their relation to blood compatibility.
    Journal of biomedical materials research, 1972, Volume: 6, Issue:4

    Topics: Action Potentials; Biocompatible Materials; Blood Coagulation; Blood Coagulation Tests; Corrosion; Fluorocarbon Polymers; Germanium; Magnesium; Metals; Microscopy, Electron; Nickel; Prostheses and Implants; Stainless Steel; Surface Properties; Surface Tension; Tantalum; Thrombosis

1972
[Experimental studies on mechanical vascular sutures].
    Wiadomosci lekarskie (Warsaw, Poland : 1960), 1966, May-15, Volume: 19, Issue:10

    Topics: Animals; Dogs; Surgical Staplers; Tantalum; Thrombosis; Vascular Surgical Procedures

1966
The use of a stapling device in experimental vascular anastomosis.
    Polish medical journal, 1966, Volume: 5, Issue:6

    Topics: Animals; Aorta, Abdominal; Blood Vessel Prosthesis; Dogs; Female; Follow-Up Studies; Iliac Artery; Male; Postoperative Complications; Surgical Staplers; Tantalum; Thrombosis; Vascular Surgical Procedures

1966