simethicone has been researched along with Colonic-Polyps* in 3 studies
1 trial(s) available for simethicone and Colonic-Polyps
Article | Year |
---|---|
Optimal Timing of Simethicone Addition for Bowel Preparation Using Polyethylene Glycol Plus Ascorbic Acid.
Colonic bubbles obscure the colonic mucosa during colonoscopy following bowel preparation with polyethylene glycol plus ascorbic acid (PEG-Asc). Simethicone is used to enhance visualization during colonoscopy. We aimed to determine the optimal timing of simethicone addition to improve bowel preparation using PEG-Asc.. This prospective, randomized study enrolled patients undergoing elective colonoscopy from April 2017 to January 2018. They were randomly assigned to one of the following three groups: PEG-Asc only (control) or simethicone addition in the morning on the day of colonoscopy (PEG-S1) or in the evening of the day prior to colonoscopy (PEG-S2). The primary outcome was the quality of colon cleansing, and the secondary outcomes were the adenoma detection rate (ADR), polyp detection rate (PDR), and diminutive (≤ 5 mm) ADR.. In total, 240 patients were randomly allocated to the three groups; six patients were withdrawn. Of the 234 patients evaluated, 78, 79, and 77 were allocated to the control, PEG-S1, and PEG-S2 groups, respectively. The bubble scores of all colonic segments were lowest in the PEG-S2 group. There was no significant difference in ADR or PDR among the three groups. However, the diminutive ADR was significantly higher in the PEG-S2 group compared to the other two groups (control 5.1% vs. PEG-S1 8.9% vs. PEG-S2 20.8%; P = 0.009).. Addition of simethicone to PEG-Asc at the optimal time prevents the formation of air bubbles and so improves the quality of bowel preparation, especially enhancing diminutive ADR. Topics: Adenoma; Adult; Aged; Antifoaming Agents; Ascorbic Acid; Cathartics; Colonic Polyps; Colonoscopy; Colorectal Neoplasms; Double-Blind Method; Drug Administration Schedule; Female; Humans; Male; Middle Aged; Polyethylene Glycols; Prospective Studies; Simethicone | 2019 |
2 other study(ies) available for simethicone and Colonic-Polyps
Article | Year |
---|---|
An in vitro and clinical dose-finding study of antifoaming effects of simethicone during colonoscopy.
Simethicone is an antifoaming agent frequently added to endoscopic rinse solutions but has recently been implicated as a risk factor for transmission of infections due to the formation of simethicone deposits within scope channels. Since the build-up of residue is likely dose-related, the smallest effective dose of simethicone should be used but there are no data available on the effective dose. Thus, we conducted a dose-finding study in an "in vitro bubble model" to determine the appropriate simethicone dose. Six 100-mL test tubes were filled with a 1% (v/v) solution of kitchen detergent (Fairy®, Procter & Gamble, London, England) in water for irrigation (Baxter®, Sydney, Australia). One test tube served as the control, while different doses of simethicone (Infacol®, Nice Pak, Melbourne, Australia) were added to the other five tubes (0.02, 0.2, 2.0, 20, and 200 mg/100 mL). Oxygen was streamed for 30 s into the test tubes at a rate of 2 L/min. After 10 s, photographs were taken and the visible bubbles were semi-quantitatively rated by independent assessors blinded to the dosing of simethicone. Simethicone at doses of 2 mg/100 mL had no appreciable antifoaming effect, whereas concentrations ≥ 20 mg/100 mL were sufficient to suppress bubble formation. This is substantially lower compared with frequently used doses of up to 200 mg/100 mL. Subsequently, we tested the lower simethicone dose with previously used higher doses, in 1475 and 1340 patients, respectively. We found it to have no impact on polyp detection with a rate of 56.7% (54.2-59.3% [95% CI]) at the lower dose and 56.5% (53.8-59.1% [95% CI]) at the higher dose. Topics: Adult; Aged; Antifoaming Agents; Colonic Polyps; Colonoscopy; Detergents; Female; Humans; In Vitro Techniques; Male; Middle Aged; Simethicone; Water | 2019 |
Influence of Simethicone Added to the Rinse Water during Colonoscopies on Polyp Detection Rates: Results of an Unintended Cohort Study.
Simethicone is a common antifoaming agent that is added to endoscopic rinse solutions, but data regarding its effect on polyp detection rates is lacking. In this study, we report the effect of discontinuation of this practice on polyp detection rates.. Procedure data of 4,254 consecutive colonoscopies were used. Patients underwent standard bowel preparation with polyethyleneglycol (Glycoprep®). Colonoscopies were performed utilising Olympus EVIS EXERA III, CV-190 equipment, while quality data (withdraw times, polyp detection rates, quality of bowel preparation) was assessed utilising an endoscopy reporting system (Provation®). Following an educational event that highlighted that simethicone may form deposits in the channels of endoscopes, the practice to add simethicone (InfacolR, Nice Pak) to the auxiliary channel water pump was abandoned, but endoscopists were not notified about this change. After 5 days and performing 75 colonoscopies, the change of practice was identified and addition of simethicone recommenced.. The discontinuation of simethicone use reduced the polyp detection rate from 55% (95% CI 53-56) to 45% (95% CI 34-56, 1-sided, p = 0.028); the polyp detection rate returned to the pre-intervention levels of 55% (95% CI 52-58) upon resumption of normal practice.. The addition of simethicone to the auxiliary water pump during colonoscopy results in a 10% increase in polyp detection rates. Topics: Antifoaming Agents; Cohort Studies; Colonic Polyps; Colonoscopes; Colonoscopy; Drug Combinations; Humans; Polyethylene Glycols; Potassium Chloride; Simethicone; Sodium Bicarbonate; Sodium Chloride; Sulfates | 2018 |