Page last updated: 2024-08-22

silver and Prosthesis Durability

silver has been researched along with Prosthesis Durability in 22 studies

Research

Studies (22)

TimeframeStudies, this research(%)All Research%
pre-19902 (9.09)18.7374
1990's5 (22.73)18.2507
2000's8 (36.36)29.6817
2010's5 (22.73)24.3611
2020's2 (9.09)2.80

Authors

AuthorsStudies
Berizzi, A; Ippolito, V; Pala, E; Ruggieri, P; Trovarelli, G1
Basile, G; Ferguson, PC; Kim, P; Rizkallah, M; Turcotte, R; Werier, J; Wilson, D1
Adragna, NC; Alla, PK; Huang, Z; Lauf, PK; Li, Y; Niu, X; Paluri, ASL; Pavel-Sizmore, IE; Shan, H; Sun, Y; Xu, H; Yaklic, J1
Jung, MK; Kim, SO; Kim, TK; Lee, TH; Pack, CG; Park, DH; Park, YK1
Fan, ZN; He, W; Liu, L; Ma, LM; Tang, XW; Wang, X; Wen, W; Zhang, Y1
Firlej, P; Kolenda, A; Olczak-Kowalczyk, D; Porenczuk, A; Szczepańska, G1
Drechsler, P; Elter, P; Ewald, A; Gbureck, U; Moseke, C; Thull, R; Zoll, A1
Butany, J; Leask, R; Scully, HE; VanArsdell, G1
Angele, MK; Blasenbreu, S; Heiss, MM; Hernández-Richter, T; Mayr, S; Schardey, HM; Schmitt-Sody, M; Wichmann, M; Wittmann, F1
Carrel, TP; Englberger, L; Holubkov, R; Im, KA; Jamieson, WR; Kennard, ED; Schaff, HV1
Andersen, KJ; Flesland, O; Julsham, K; Rait, M; Rungby, J; Sudmann, E; Todnem, K; Vik, H1
Kahn, FH; Pines, M; Rosenberg, PA; Schulman, A1
Biedlingmaier, JF; Malaisrie, SC; Malekzadeh, S1
Herold, U; Jakob, H; Piotrowski, J; Van De Wal, H1
Al-Darweesh, A; Stumpe, F; Tozzi, P; Vogt, P1
Flameng, W; Herijgers, P; Herregods, MC; Meyns, B; Vandeplas, A1
Auer, J; Berent, R; Eber, B; Hartl, P; Lassnig, E; Mayr, H; Ng, CK; Punzengruber, C; Puschmann, R; Schwarz, C1
Hillion, ML; Houël, R; Kirsch, M; Loisance, D1
Aquilino, SA; Diaz-Arnold, AM; Leary, JM; Ryther, JS1
Levi, J1
Melman, A; Mieza, M; Pedersen, B1
Gregory, JG; Tawil, EA1

Reviews

1 review(s) available for silver and Prosthesis Durability

ArticleYear
High-tech removal of fractured posts, silver points and separated devices.
    Journal of the New Jersey Dental Association, 1991,Winter, Volume: 62, Issue:1

    Topics: Foreign Bodies; Humans; Post and Core Technique; Prosthesis Failure; Silver; Ultrasonics

1991

Trials

4 trial(s) available for silver and Prosthesis Durability

ArticleYear
    Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery, 2019, Sep-15, Volume: 33, Issue:9

    Topics: Adolescent; Adult; Aged; Aged, 80 and over; Bone and Bones; Bone Neoplasms; Cells, Cultured; Child; Erythrocytes; Female; Humans; Ion Transport; Lower Extremity; Male; Metal Nanoparticles; Middle Aged; Particle Size; Potassium; Prosthesis Failure; Prosthesis Implantation; Retrospective Studies; Rubidium; Silver; Treatment Outcome; Young Adult

2019
Safety and efficacy of a metal stent covered with a silicone membrane containing integrated silver particles in preventing biofilm and sludge formation in endoscopic drainage of malignant biliary obstruction: a phase 2 pilot study.
    Gastrointestinal endoscopy, 2019, Volume: 90, Issue:4

    Topics: Aged; Ampulla of Vater; Bile; Biofilms; Carcinoma, Hepatocellular; Cholangitis; Cholestasis; Common Bile Duct Neoplasms; Drainage; Endoscopy, Digestive System; Female; Gallbladder Neoplasms; Humans; Liver Neoplasms; Male; Metal Nanoparticles; Microscopy, Electron, Scanning; Middle Aged; Palliative Care; Pancreatic Neoplasms; Pancreatitis; Pilot Projects; Postoperative Complications; Prosthesis Failure; Self Expandable Metallic Stents; Silicones; Silver

2019
Importance of implant technique on risk of major paravalvular leak (PVL) after St. Jude mechanical heart valve replacement: a report from the Artificial Valve Endocarditis Reduction Trial (AVERT).
    European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery, 2005, Volume: 28, Issue:6

    Topics: Aged; Aortic Valve; Coated Materials, Biocompatible; Endocarditis, Bacterial; Female; Follow-Up Studies; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Humans; Male; Middle Aged; Mitral Valve; Prosthesis Failure; Risk Factors; Silver; Suture Techniques

2005
Silzone coating and paravalvular leak: an independent, randomized study.
    The Journal of heart valve disease, 2001, Volume: 10, Issue:6

    Topics: Aged; Cohort Studies; Echocardiography; Female; Follow-Up Studies; Heart Valve Diseases; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Humans; L-Lactate Dehydrogenase; Male; Middle Aged; Outcome Assessment, Health Care; Prosthesis Failure; Silver; Time Factors

2001

Other Studies

17 other study(ies) available for silver and Prosthesis Durability

ArticleYear
A long-term experience with Mutars tumor megaprostheses: analysis of 187 cases.
    European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2022, Volume: 48, Issue:3

    Topics: Bone Neoplasms; Femur; Humans; Prostheses and Implants; Prosthesis Failure; Reoperation; Retrospective Studies; Silver; Tibia; Treatment Outcome

2022
LUMiC® endoprosthesis for pelvic reconstruction: A Canadian experience.
    Journal of surgical oncology, 2023, Volume: 127, Issue:4

    Topics: Artificial Limbs; Bone Neoplasms; Canada; Humans; Prosthesis Design; Prosthesis Failure; Reoperation; Retrospective Studies; Silver; Treatment Outcome

2023
Silver-nanoparticle-coated biliary stent inhibits bacterial adhesion in bacterial cholangitis in swine.
    Hepatobiliary & pancreatic diseases international : HBPD INT, 2016, Volume: 15, Issue:1

    Topics: Alanine Transaminase; Animals; Anti-Bacterial Agents; Bacterial Adhesion; Biofilms; Biomarkers; Cholangiopancreatography, Endoscopic Retrograde; Cholangitis; Coated Materials, Biocompatible; Cytokines; Disease Models, Animal; Feasibility Studies; Inflammation Mediators; Nanoparticles; Polyurethanes; Prosthesis Design; Prosthesis Failure; Silver; Stents; Swine; Time Factors

2016
The laboratory comparison of shear bond strength and microscopic assessment of failure modes for a glass-ionomer cement and dentin bonding systems combined with silver nanoparticles.
    Acta of bioengineering and biomechanics, 2016, Volume: 18, Issue:2

    Topics: Dental Bonding; Dental Stress Analysis; Dentin; Dentin-Bonding Agents; Elements; Glass Ionomer Cements; Humans; Metal Nanoparticles; Microscopy, Electron, Scanning; Prosthesis Failure; Shear Strength; Silver

2016
Hard implant coatings with antimicrobial properties.
    Journal of materials science. Materials in medicine, 2011, Volume: 22, Issue:12

    Topics: Anti-Infective Agents; Crystallography, X-Ray; Hardness; Humans; Ions; Materials Testing; Microbial Sensitivity Tests; Microscopy, Electron, Scanning; Osteoblasts; Prostheses and Implants; Prosthesis Failure; Silver; Staphylococcal Infections; Staphylococcus aureus; Staphylococcus epidermidis; Surface Properties; Titanium

2011
Prosthetic heart valves with silver-coated sewing cuff fabric: early morphological features in two patients.
    The Canadian journal of cardiology, 2002, Volume: 18, Issue:7

    Topics: Endocarditis, Bacterial; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Humans; Mitral Valve; Prosthesis Design; Prosthesis Failure; Prosthesis-Related Infections; Reoperation; Retrospective Studies; Silver

2002
[Experimental examination concerning the efficacy of silver-coated Dacron prostheses in vascular graft infections following subcutaneous implantation in a standardized infection model].
    Zentralblatt fur Chirurgie, 2003, Volume: 128, Issue:3

    Topics: Animals; Blood Vessel Prosthesis; Coated Materials, Biocompatible; Colony Count, Microbial; Male; Mice; Mice, Inbred C3H; Polyethylene Terephthalates; Prosthesis Design; Prosthesis Failure; Prosthesis-Related Infections; Rifampin; Silver; Staphylococcal Infections; Subcutaneous Tissue; Surgical Wound Infection

2003
Systemic and local silver accumulation after total hip replacement using silver-impregnated bone cement.
    Medical progress through technology, 1994, Volume: 20, Issue:3-4

    Topics: Aged; Body Burden; Bone Cements; Female; Hip Prosthesis; Humans; Paralysis; Prosthesis Failure; Reoperation; Silver

1994
Comparison of fatigue for three prefabricated threaded post systems.
    The Journal of prosthetic dentistry, 1996, Volume: 75, Issue:2

    Topics: Cementation; Dental Amalgam; Dental Cavity Preparation; Dental Prosthesis Design; Dental Stress Analysis; Dentin; Humans; Materials Testing; Post and Core Technique; Prosthesis Failure; Root Canal Therapy; Silver; Stainless Steel; Stress, Mechanical; Surface Properties; Temperature; Titanium; Tooth Fractures; Tooth Root

1996
In vivo analysis of bacterial biofilm formation on facial plastic bioimplants.
    The Laryngoscope, 1998, Volume: 108, Issue:11 Pt 1

    Topics: Animals; Anti-Infective Agents, Local; Bacterial Adhesion; Biocompatible Materials; Biofilms; Chlorhexidine; Coated Materials, Biocompatible; Dermatologic Surgical Procedures; Face; Guinea Pigs; Materials Testing; Microscopy, Electron, Scanning; Plastic Surgery Procedures; Polyethylenes; Polytetrafluoroethylene; Prostheses and Implants; Prosthesis Failure; Prosthesis Implantation; Prosthesis-Related Infections; Silicones; Silver; Staphylococcus aureus; Suppuration; Surface Properties; Surgical Wound Infection; Titanium

1998
Disruption of the silver and non-silver coated sewing cuff of a new generation bileaflet valve prosthesis during aortic valve replacement: report on four cases.
    European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery, 2000, Volume: 18, Issue:2

    Topics: Aortic Valve; Coated Materials, Biocompatible; Heart Valve Diseases; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Humans; Intraoperative Complications; Prosthesis Failure; Silver; Sutures

2000
Silver-coated prosthetic heart valve: a double-bladed weapon.
    European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery, 2001, Volume: 19, Issue:5

    Topics: Aged; Female; Heart Valve Prosthesis; Humans; Hypersensitivity; Mitral Valve; Mitral Valve Insufficiency; Prosthesis Design; Prosthesis Failure; Prosthesis-Related Infections; Silver

2001
Early investigation of silver-coated Silzone heart valves prosthesis in 126 patients.
    The Journal of heart valve disease, 2001, Volume: 10, Issue:6

    Topics: Adult; Aged; Aged, 80 and over; Echocardiography; Female; Heart Valve Diseases; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Hospital Mortality; Humans; Male; Middle Aged; Postoperative Complications; Prosthesis Failure; Silver; Stroke; Time Factors; Treatment Outcome

2001
Silzone-coated St. Jude medical valve: a safe valve.
    The Journal of heart valve disease, 2001, Volume: 10, Issue:6

    Topics: Actuarial Analysis; Adult; Aged; Aged, 80 and over; Female; Follow-Up Studies; Heart Valve Diseases; Heart Valve Prosthesis; Humans; Male; Middle Aged; Prosthesis Failure; Risk Factors; Silver; Thromboembolism; Time Factors

2001
Evaluation of the fracture resistance of a wrought post compared with completely cast post and cores.
    The Journal of prosthetic dentistry, 1992, Volume: 68, Issue:3

    Topics: Analysis of Variance; Dental Alloys; Dental Casting Technique; Gold Alloys; Materials Testing; Palladium; Post and Core Technique; Prosthesis Failure; Silver

1992
Instability and rotation of silver silicone penile prosthesis.
    Urology, 1988, Volume: 31, Issue:2

    Topics: Adult; Aged; Humans; Male; Middle Aged; Penis; Prostheses and Implants; Prosthesis Failure; Silicones; Silver

1988
Failure of the Jonas prosthesis.
    The Journal of urology, 1986, Volume: 135, Issue:4

    Topics: Humans; Male; Penis; Prostheses and Implants; Prosthesis Failure; Silicones; Silver; Time Factors

1986