silicon-nitride and Neck-Pain

silicon-nitride has been researched along with Neck-Pain* in 2 studies

Trials

2 trial(s) available for silicon-nitride and Neck-Pain

ArticleYear
Porous silicon nitride spacers versus PEEK cages for anterior cervical discectomy and fusion: clinical and radiological results of a single-blinded randomized controlled trial.
    European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2017, Volume: 26, Issue:9

    Anterior cervical discectomy with fusion is a common procedure for treating radicular arm pain. Polyetheretherketone (PEEK) plastic is a frequently used material in cages for interbody fusion. Silicon nitride is a new alternative with desirable bone compatibility and imaging characteristics. The aim of the present study is to compare silicon nitride implants with PEEK cages filled with autograft harvested from osteophytes.. The study is a prospective, randomized, blinded study of 100 patients with 2 years follow-up. The primary outcome measure was improvement in the Neck Disability Index. Other outcome measures included SF-36, VAS arm pain, VAS neck pain, assessment of recovery, operative characteristics, complications, fusion and subsidence based on dynamic X-ray and CT scan.. There was no significant difference in NDI scores between the groups at 24 months follow-up. At 3 and 12 months the NDI scores were in favor of PEEK although the differences were not clinically relevant. On most follow-up moments there was no difference in VAS neck and VAS arm between both groups, and there was no statistically significant difference in patients' perceived recovery during follow-up. Fusion rate and subsidence were similar for the two study arms and about 90% of the implants were fused at 24 months.. Patients treated with silicon nitride and PEEK reported similar recovery rates during follow-up. There was no significant difference in clinical outcome at 24 months. Fusion rates improved over time and are comparable between both groups.

    Topics: Adult; Aged; Benzophenones; Biocompatible Materials; Bone Transplantation; Cervical Vertebrae; Disability Evaluation; Diskectomy; Female; Humans; Intervertebral Disc Displacement; Ketones; Male; Middle Aged; Neck Pain; Osteophyte; Pain Measurement; Polyethylene Glycols; Polymers; Prospective Studies; Prostheses and Implants; Radiography; Silicon Compounds; Single-Blind Method; Spinal Fusion; Treatment Outcome; Young Adult

2017
The CASCADE trial: effectiveness of ceramic versus PEEK cages for anterior cervical discectomy with interbody fusion; protocol of a blinded randomized controlled trial.
    BMC musculoskeletal disorders, 2013, Aug-16, Volume: 14

    Anterior cervical discectomy with interbody fusion cages is considered the standard surgical procedure in patients with cervical disc herniation. However, PEEK or metal cages have some undesirable imaging characteristics, leading to a search for alternative materials not creating artifacts on images; silicon nitride ceramic. Whether patients treated with silicon nitride ceramic cages have similar functional outcome as patients treated with PEEK cages is not known. We present the design of the CASCADE trial on effectiveness of ceramic cages versus PEEK cages in patients with cervical disc herniation and/or osteophytes.. Patients (age 18-75 years) with monoradicular symptoms in one or both arms lasting more than 8 weeks, due to disc herniation and/or osteophytes, are eligible for the trial. The study is designed as a randomized controlled equivalence trial in which patients are blinded to the type of cage for 1 year. The total follow-up period is 2 years. The primary outcome measure is improvement in the Neck and Disability Index (NDI). Secondary outcomes measures include improvement in arm pain and neck pain (VAS), SF-36 and patients' perceived recovery. The final elements of comparison are perioperative statistics including operating time, blood loss, length of hospital stay, and adverse events. Lateral plane films at each follow-up visit and CT scan (at 6 months) will be used to judge fusion and the incidence of subsidence. Based on a power of 90% and assuming 8% loss to follow-up, 100 patients will be randomized into the 2 groups. The first analysis will be conducted when all patients have 1 year of follow-up, and the groups will be followed for 1 additional year to judge stability of outcomes.. While the new ceramic cage has received the CE Mark based on standard compliance and animal studies, a randomized comparative study with the golden standard product will provide more conclusive information for clinicians. Implementation of any new device should only be done after completion of randomized controlled effectiveness trials.

    Topics: Adolescent; Adult; Aged; Bone Plates; Ceramics; Cervical Vertebrae; Clinical Protocols; Disability Evaluation; Diskectomy; Humans; Intervertebral Disc Displacement; Middle Aged; Neck Pain; Osteophyte; Pain Measurement; Research Design; Silicon Compounds; Single-Blind Method; Spinal Fusion; Treatment Outcome; Young Adult

2013