silicon has been researched along with Pituitary-Neoplasms* in 2 studies
1 trial(s) available for silicon and Pituitary-Neoplasms
Article | Year |
---|---|
Treatment accuracy of fractionated stereotactic radiotherapy.
To assess the geometric accuracy of the delivery of fractionated stereotactic radiotherapy (FSRT) for brain tumours using the Gill-Thomas-Cosman (GTC) relocatable frame. Accuracy of treatment delivery was measured via portal images acquired with an amorphous silicon based electronic portal imager (EPI). Results were used to assess the existing verification process and to review the current margins used for the expansion of clinical target volume (CTV) to planning target volume (PTV).. Patients were immobilized in a GTC frame. Target volume definition was performed on localization CT and MRI scans and a CTV to PTV margin of 5mm (based on initial experience) was introduced in 3D. A Brown-Roberts-Wells (BRW) fiducial system was used for stereotactic coordinate definition. The existing verification process consisted of an intercomparison of the coordinates of the isocentres and anatomy between the localization and verification CT scans. Treatment was delivered with 6 MV photons using four fixed non-coplanar conformal fields using a multi-leaf collimator. Portal imaging verification consisted of the acquisition of orthogonal images centred through the treatment isocentre. Digitally reconstructed radiographs (DRRs) created from the CT localization scans were used as reference images. Semi-automated matching software was used to quantify set up deviations (displacements and rotations) between reference and portal images.. One hundred and twenty six anterior and 123 lateral portal images were available for analysis for set up deviations. For displacements, the total errors in the cranial/caudal direction were shown to have the largest SD's of 1.2 mm, while systematic and random errors reached SD's of 1.0 and 0.7 mm, respectively, in the cranial/caudal direction. The corresponding data for rotational errors (the largest deviation was found in the sagittal plane) was 0.7 degrees SD (total error), 0.5 degrees (systematic) and 0.5 degrees (random). The total 3D displacement was 1.8 mm (mean), 0.8 mm (SD) with a range of 0.3-3.9 mm.. Portal imaging has shown that the existing verification and treatment delivery techniques currently in use result in highly reproducible setups. Random and systematic errors in the treatment planning and delivery chain will always occur, but monitoring and minimising them is an essential component of quality control. Portal imaging provides fast and accurate facility for monitoring patients on treatment and the results of this study have shown that a reduction in CTV to PTV margin from 5 to 4 mm (resulting in a considerable increase in the volume of normal tissue sparing) could be made. Topics: Adenoma; Craniopharyngioma; Dose Fractionation, Radiation; Humans; Immobilization; Magnetic Resonance Imaging; Meningeal Neoplasms; Meningioma; Neuroma, Acoustic; Photons; Pituitary Neoplasms; Radiotherapy; Sensitivity and Specificity; Silicon; Stereotaxic Techniques; Tomography, X-Ray Computed | 2005 |
1 other study(ies) available for silicon and Pituitary-Neoplasms
Article | Year |
---|---|
Expanded endoscopic endonasal transsphenoidal approach to determine morphological characteristics and clinical considerations of the cavernous sinus venous spaces.
The study aimed at investigating the morphological characteristics and interconnected regularities of the cavernous sinus (CS) venous spaces using an expanded endoscopic endonasal transsphenoidal approach. Surgical dissections were performed for 15-colored silicon-injected human head specimens. The CS venous spaces were examined for their morphological and clinical characteristics using an expanded endoscopic endonasal transsphenoidal approach. The intracavernous course of the internal carotid artery (ICA) divided the CS venous spaces into four interconnected virtual compartments: medial, anteroinferior, posterosuperior, and lateral. The CS venous spaces had peculiar morphological characteristics; the medial compartment was C-shaped while the anteroinferior compartment resembled a boat's bow. The mean distances from the medial border of the inferior horizontal segment of cavernous ICA to the mid-line of the pituitary gland (PG) were 6.07 ± 1.61 mm (left) and 5.97 ± 1.89 mm (right); the mean distances from the medial border of the subarachnoid segment of cavernous ICA to the mid-line of the PG were 5.77 ± 1.16 mm (left) and 5.63 ± 1.17 mm (right); the mean distances from the medial border of the anterior vertical segment of cavernous ICA to the mid-line of the PG were 10.27 ± 1.74 mm (left) and 10.47 ± 1.90 mm (right). Morphological characteristics and the knowledge of the interconnected regularities of the CS venous spaces may help surgeons accurately locate the neurovascular structure, and thus may contribute to the effective prediction of tumor invasion and extension during endoscopic CS surgery. Topics: Cavernous Sinus; Endoscopy; Humans; Pituitary Gland; Pituitary Neoplasms; Silicon | 2022 |