silicon and Aortic-Aneurysm--Abdominal

silicon has been researched along with Aortic-Aneurysm--Abdominal* in 3 studies

Other Studies

3 other study(ies) available for silicon and Aortic-Aneurysm--Abdominal

ArticleYear
In Vitro Radiological Evaluation of Different Types of Chimney Stents Using a Silicon Flow Model with Adjustable Physiological Simulating Conditions.
    European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery, 2023, Volume: 66, Issue:2

    To evaluate in vitro the performance of in vivo published covered or bare metal chimney stents (ChSs) in combination with the Endurant II abdominal endograft (Medtronic) as the only CE approved main graft (MG) in the treatment of juxtarenal abdominal aortic aneurysms with the chimney endovascular aneurysm repair (chEVAR) technique.. Bench top experimental study. A silicon flow model with adjustable physiological simulating conditions and patient based anatomy was used to test nine different MG-ChS combinations: Advanta V12 (Getinge); BeGraft. Bland-Altman analysis confirmed adequate results correlation (p < .05). Each employed ChS showed significantly different performance favouring the balloon expandable covered stent (BECS). The smallest gutter area was seen in the combination with Advanta V12 (0.26 cm. This in vitro study shows the variability of performance with each theoretically possible ChS and explains the divergent ChS outcomes in the published literature. BECS in combination with the Endurant abdominal device confirms their superiority vs. BMS. The presence of MG infolding in each test underlines the need for prolonged kissing ballooning. Angulation evaluation and comparison with other in vitro and in vivo publications demands the need for further investigation in transversely or upwardly oriented target vessels.

    Topics: Aortic Aneurysm, Abdominal; Blood Vessel Prosthesis; Blood Vessel Prosthesis Implantation; Endovascular Procedures; Humans; Prosthesis Design; Silicon; Stents; Treatment Outcome

2023
The best in vitro conditions for two and three parallel stenting during endovascular aneurysm repair.
    Journal of vascular surgery, 2017, Volume: 66, Issue:4

    The aim of this study is to identify which endograft-parallel stent combinations and which degree of oversizing result in the most adequate fit in a juxtarenal abdominal aneurysmal neck, when using a double or triple parallel-stent (chimney) technique.. In vitro silicon, juxtarenal, abdominal aortic aneurysmal neck models of different diameters, with two and three side-branches (simulating both the renal and superior mesenteric arteries), were constructed. Two different endografts of three diameters each, with two or three parallel stents (of 6 mm and 6 mm; or 6 mm, 6 mm, and 8 mm) were tested (Endurant-II endograft [Medtronic Inc, Santa Rosa, Calif] with balloon-expandable BeGraft stent [Bentley InnoMed, Hechingen, Germany] and an Excluder endograft [W. L. Gore and Associates, Flagstaff, Ariz] with self-expanding Viabahn stent [W. L. Gore and Associates]), applying three endograft-oversizing degrees: recommended (15%), excessive (30%), and over-excessive (40%). After remodeling, using the kissing-balloon technique at 37°C (98.6°F), 36 endograft-stent-oversizing models were scanned by computed tomography. The area of the gutters, parallel-stent compression, and main endograft infolding were recorded.. Increasing oversizing (15%, 30%, and 40%) revealed a nonsignificant propensity toward smaller gutters and similar parallel-stent compression, but it significantly augmented infolding, more in three parallel-stent models (0%, 0%, 67% and 0%, 33%, 83% of cases; P = .015 and .018, for two and three parallel-stent models; n = 36) and mainly for the Excluder-Viabahn combination. The Excluder-Viabahn showed significantly smaller gutters, but with higher stent compression, than Endurant-BeGraft combinations for both two and three parallel stents (8.2 mm. Better endograft stent apposition was usually attained when using 30% oversizing during two and three parallel-stent techniques. Higher oversizing was related to nonsignificant smaller gutters but higher rates of infolding. Smaller gutters, but higher stent compression and risk of infolding, were achieved with the Excluder-Viabahn than with the Endurant-BeGraft combination.

    Topics: Aorta, Abdominal; Aortic Aneurysm, Abdominal; Aortography; Blood Vessel Prosthesis; Blood Vessel Prosthesis Implantation; Computed Tomography Angiography; Endovascular Procedures; Humans; Models, Anatomic; Models, Cardiovascular; Prosthesis Design; Silicon; Stents

2017
Balloon embolization of the internal iliac artery before aneurysm endograft deployment.
    Journal of vascular and interventional radiology : JVIR, 2001, Volume: 12, Issue:5

    Six patients, ranging from 69 to 81 years of age, underwent iliac artery embolization with use of Detachable Silicon Balloons (DSB) 11-14 days before stent-graft repair of aneurysms. Balloons of 8.8-mm, 9.4-mm, and 9.9-mm sizes were used with 20-30 g of release force. Deployment difficulty was experienced in three cases. Five of six cases were successful, with the iliac artery remaining occluded at the time of endografting; one case required subsequent coil replacement. The average operative time for balloon embolization (75 min +/- 28) was shorter than that in 18 cases of coil embolization performed within the same time period (111 min +/- 105), but the difference was not significant (P = .21). Postoperatively, one patient (17%) reported buttock claudication after the procedure. Use of the DSB represents an alternative to use of coils for embolization of large and tortuous iliac arteries.

    Topics: Aged; Aged, 80 and over; Aneurysm; Angiography, Digital Subtraction; Aortic Aneurysm, Abdominal; Balloon Occlusion; Blood Vessel Prosthesis; Humans; Iliac Artery; Male; Postoperative Complications; Silicon; Stents

2001