shu-508 and Thyroid-Nodule

shu-508 has been researched along with Thyroid-Nodule* in 2 studies

Other Studies

2 other study(ies) available for shu-508 and Thyroid-Nodule

ArticleYear
Ultrasonographic contrast agent: evaluation of time-intensity curves in the characterisation of solitary thyroid nodules.
    La Radiologia medica, 2002, Volume: 103, Issue:4

    To evaluate whether the time-intensity curve can improve characterisation of solitary thyroid nodules.. From June to December 2000 we studied 61 patients (16 men and 45 women, mean age 46 years) with solitary thyroid nodules that were not associated with any important hormonal alteration and that showed poor tracer uptake at scintigraphy. We evaluated the Power Doppler vascular pattern before and after a 60" intravenous injection of 2.5 g of Levovist (diluted in 7 ml). The study lasted 5 minutes from the beginning of the infusion. Finally, the time-intensity curves were processed. All the nodules underwent fine needle aspiration biopsy (FNAB) and excision biopsy.. Histology revealed 43 benign lesions and 18 malignant lesions. At contrast-enhanced Power Doppler 83.4% (15/18) of the malignant nodules were found to be hypervascularized, while 16.6% (3/18) were hypovascularized. Of the benign lesions, 90.7% (39/43) were hypervascularized, 9.3% (4/43) were hypovascularized. All the nodules, both hyper- and hypovascularized, displayed rapid and intense wash-in curves. By contrast, the wash-out curves were regular and monophasic in 40/43 (93%) benign lesions (36 hypervascularized and 4 hypovascularized lesions) and irregular and polyphasic in 16/18 (89%) malignant lesions (13 hypervascularized and 3 hypovascularized lesions); 3/43 (7%) benign nodules showed polyphasic wash-out and 2/18 malignant lesions (11%) showed monophasic wash-out.. Time-intensity curves, and particularly wash-out curves, provide useful information for the characterisation of solitary thyroid nodules. 93% of benign nodules (with regular vascularization) showed a monophasic pattern of the wash-out curve, while 89% of malignant nodules ("anarchical" vascularization) had polyphasic wash-out curves. This behaviour was observed in both hypervascularized and hypovascularized lesions. Our method proved to have a sensitivity of 88% and a specificity of 93%. The study of time-intensity curves could therefore enable us to differentiate between benign and malignant lesions and characterise hypovascularized malignant nodules which would not be observed without contrast agent.

    Topics: Adult; Aged; Biopsy, Needle; Contrast Media; Diagnosis, Differential; Female; Humans; Male; Middle Aged; Polysaccharides; Sensitivity and Specificity; Thyroid Nodule; Ultrasonography, Doppler

2002
Analysis of color Doppler signal intensity variation after levovist injection: a new approach to the diagnosis of thyroid nodules.
    Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine, 2001, Volume: 20, Issue:3

    The objective of this study was to evaluate the usefulness of a galactose-based ultrasonographic contrast agent, Levovist (Schering AG, Berlin, Germany), in differentiating benign from malignant thyroid nodules by analysis of the time-intensity curves correlating the variation of the intensity signal value during the contrast transit time. Fifty-four patients scheduled for surgical removal of a nodule or the thyroid gland or both after cytologic examination were enrolled in this study; all of the nodules underwent a baseline color and power Doppler evaluation and then to a color Doppler examination after an intravenous bolus injection of Levovist. The time-intensity curves were analyzed with respect to the histologic results. Carcinomas showed a significantly earlier arrival time of Levovist than nodular hyperplastic benign nodules and adenomas (8.1 +/- 1.41 versus 19.6 +/- 2.2 and 16.1 +/- 2.8 seconds; P < .0001), although no significant difference occurred between hyperplastic benign nodules and adenomas; carcinomas and adenomas showed an earlier time to peak than hyperplastic benign nodules (14.6 +/- 1.2 and 23.1 +/- 3.8 versus 33.0 +/- 3.0 seconds; P < .0001). No significant difference was found in baseline, peak, final intensity signal, and percent variation of intensity signal among hyperplastic benign nodules, adenomas, and carcinomas. Although cytologic examination still remains the standard of reference for the presurgical diagnosis of thyroid nodules, the preliminary data of this pilot study demonstrate that the analysis of time-intensity curves after Levovist injection might provide useful, complementary, and quantitative information to differentiate benign from malignant thyroid nodules.

    Topics: Adult; Aged; Analysis of Variance; Contrast Media; Diagnosis, Differential; Female; Humans; Injections, Intravenous; Male; Middle Aged; Pilot Projects; Polysaccharides; Thyroid Neoplasms; Thyroid Nodule; Ultrasonography, Doppler, Color

2001