phosphorus has been researched along with Prosthesis Durability in 17 studies
Timeframe | Studies, this research(%) | All Research% |
---|---|---|
pre-1990 | 0 (0.00) | 18.7374 |
1990's | 4 (23.53) | 18.2507 |
2000's | 7 (41.18) | 29.6817 |
2010's | 5 (29.41) | 24.3611 |
2020's | 1 (5.88) | 2.80 |
Authors | Studies |
---|---|
Furukawa, T; Go, S; Hiraoka, T; Mochizuki, S; Takahashi, S; Yamada, K | 1 |
Ayers, R; Burger, E; Kleck, C; Miller, M; Patel, V; Schowinsky, J | 1 |
Habib, NE; Moate, RM; Park, JC | 1 |
De Keizer, RJ; NĂ Dhubhghaill, S; Taal, M; Tassignon, MJ; Van Os, L; Zakaria, N | 1 |
Bhate, M; Bojja, S; Jalali, S; Pehere, NK; Samant, M; Vaddavalli, PK; Vemuganti, GK | 1 |
Matsumura, K; Nemoto, N; Shimizu, K; Takano, M | 1 |
Au Eong, KG; Heng, WJ; Lee, HM; Netto, PA; Ng, MM; Yap, EY; Yong, VK | 1 |
Lovekamp, JJ; Simionescu, DT; Vyavahare, NR | 1 |
Botton, G; Brownstein, S; Dorey, MW; El-Defrawy, S; Hill, VE; Kertes, PJ; Mathew, B | 1 |
Chen, KH; Hsu, WM; Lai, JY; Lee, TH; Lin, SY | 1 |
Dick, AD; Ferguson, DJ; Knox Cartwright, NE; Mayer, EJ; McDonald, BM; Salter, CJ; Skinner, A; Sparrow, JM; Tole, DM | 1 |
Apple, DJ; Assia, EI; de Borin, OA; Kleinmann, G; Laws, DE; Mamalis, N; Neuhann, IM; Pandey, SK; Werner, L | 1 |
Nakanome, S; Tanaka, K; Tochikubo, T; Watanabe, H | 1 |
Cambillau, M; Carpentier, A; Carpentier, S; Castaldo, F; Farge, D; Gardin, JP; Puaud, AC; Shen, M | 1 |
Carpentier, A; Carpentier, S; Chen, L; Daudon, M; Farge, D; Lacour, B; Martinet, B; Pellerin, M; Shen, M | 1 |
Aebi, U; Hefti, A; Morscher, EW | 1 |
Baba, HA; Deiwick, M; Glasmacher, B; Reul, H; Roeder, N; Scheld, HH; von Bally, G | 1 |
17 other study(ies) available for phosphorus and Prosthesis Durability
Article | Year |
---|---|
Strict control of phosphorus concentration of hemodialysis patients may decrease structural valve deterioration after aortic valve replacement.
Topics: Aortic Valve; Aortic Valve Stenosis; Bioprosthesis; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Humans; Phosphorus; Prosthesis Design; Prosthesis Failure; Renal Dialysis; Retrospective Studies; Treatment Outcome | 2022 |
Three cases of metallosis associated with spine instrumentation.
Topics: Aged; Calcium; Chromium; Cobalt; Corrosion; Female; Humans; Ions; Iron; Lumbar Vertebrae; Male; Materials Testing; Metals; Middle Aged; Nickel; Patient Readmission; Patient-Centered Care; Phosphorus; Prostheses and Implants; Prosthesis Failure; Reference Values; Spine; Titanium; Tomography, X-Ray Computed; Treatment Outcome | 2017 |
Intraocular lens opacification after corneal endothelial keratoplasty: electron microscopy and x-ray element spectroscopy analysis.
Topics: Aged; Aged, 80 and over; Calcium; Descemet Stripping Endothelial Keratoplasty; Device Removal; Electron Probe Microanalysis; Female; Humans; Lens Implantation, Intraocular; Lenses, Intraocular; Male; Microscopy, Electron, Scanning; Middle Aged; Phacoemulsification; Phosphorus; Prosthesis Failure; Retrospective Studies | 2015 |
Intraocular lens exchange technique for an opacified bag-in-the-lens.
Topics: Aged; Calcinosis; Calcium; Device Removal; Electron Probe Microanalysis; Female; Humans; Lens Implantation, Intraocular; Lenses, Intraocular; Microscopy, Electron, Scanning; Oxygen; Phacoemulsification; Phosphorus; Prosthesis Failure; Reoperation | 2015 |
Opacification of intraocular lenses implanted during infancy: a clinicopathologic study of 4 explanted intraocular lenses.
Topics: Acrylic Resins; Aqueous Humor; Calcium; Cataract; Cataract Extraction; Device Removal; Humans; Infant; Infant, Newborn; Lens Implantation, Intraocular; Lenses, Intraocular; Microscopy, Electron, Scanning; Phosphorus; Prosthesis Failure; Retinopathy of Prematurity; Spectrometry, X-Ray Emission | 2011 |
Silicone intraocular lens surface calcification in a patient with asteroid hyalosis.
Topics: Aged, 80 and over; Calcinosis; Calcium; Calcium Phosphates; Device Removal; Electron Probe Microanalysis; Eye Diseases; Humans; Lenses, Intraocular; Male; Microscopy, Electron, Scanning; Phosphorus; Prosthesis Failure; Reoperation; Silicone Elastomers; Vitreous Body | 2012 |
Visually significant opacification of hydrophilic acrylic intraocular lenses--a clinico-pathological analysis.
Topics: Acrylic Resins; Biocompatible Materials; Calcinosis; Calcium; Device Removal; Electron Probe Microanalysis; Humans; Lens Implantation, Intraocular; Lenses, Intraocular; Microscopy, Electron, Scanning; Phacoemulsification; Phosphorus; Prosthesis Failure; Retrospective Studies | 2003 |
Glycosaminoglycan-degrading enzymes in porcine aortic heart valves: implications for bioprosthetic heart valve degeneration.
Topics: Animals; Aortic Valve; Bioprosthesis; Calcinosis; Calcium; Chondroitinases and Chondroitin Lyases; Disease Models, Animal; Disease Susceptibility; Electrophoresis; Fixatives; Gelatinases; Glutaral; Glycosaminoglycans; Heart Valve Diseases; Heart Valve Prosthesis; Hyaluronoglucosaminidase; Male; Models, Cardiovascular; Phosphorus; Prosthesis Failure; Rats; Rats, Sprague-Dawley; Swine | 2003 |
Proposed pathogenesis for the delayed postoperative opacification of the hydroview hydrogel intraocular lens.
Topics: Aged; Aged, 80 and over; Biocompatible Materials; Calcinosis; Calcium; Device Removal; Electron Probe Microanalysis; Female; Humans; Lens Implantation, Intraocular; Lenses, Intraocular; Male; Microscopy, Electron; Middle Aged; Phacoemulsification; Phosphorus; Polyhydroxyethyl Methacrylate; Product Packaging; Prosthesis Failure; Reoperation; Silicones | 2003 |
Multiple elements in the deposits of opacified Hydroview intraocular lens.
Topics: Acrylic Resins; Calcium; Cations; Device Removal; Electron Probe Microanalysis; Female; Fluorine; Humans; Lenses, Intraocular; Magnesium; Male; Microscopy, Electron, Scanning; Phosphorus; Prosthesis Failure; Sodium | 2005 |
Ultrastructural evaluation of explanted opacified Hydroview (H60M) intraocular lenses.
Topics: Calcium; Device Removal; Humans; Lenses, Intraocular; Microscopy, Electron, Scanning; Phosphorus; Prosthesis Failure; Surface Properties | 2007 |
Postoperative surface deposits on intraocular lenses in children.
Topics: Anthraquinones; Biocompatible Materials; Calcinosis; Calcium; Child, Preschool; Device Removal; Electron Probe Microanalysis; Humans; Infant; Lenses, Intraocular; Male; Microscopy, Electron, Scanning; Phosphorus; Postoperative Complications; Prosthesis Failure; Reoperation; Staining and Labeling | 2006 |
Calcification of Hydroview H60M intraocular lenses: aqueous humor analysis and comparisons with other intraocular lens materials.
Topics: Acrylic Resins; Albumins; Aqueous Humor; Blood-Aqueous Barrier; Calcinosis; Calcium; Capillary Permeability; Diabetic Retinopathy; Electron Probe Microanalysis; Humans; Lens Implantation, Intraocular; Lenses, Intraocular; Microscopy, Electron, Scanning; Phacoemulsification; Phosphorus; Polymethyl Methacrylate; Prosthesis Failure; Reoperation; Silicone Elastomers | 2008 |
[Phosphocalcium metabolism in patients with calcified valvular bioprosthesis].
Topics: Aortic Valve; Bioprosthesis; Calcinosis; Calcium; Female; Heart Valve Prosthesis; Humans; Male; Middle Aged; Mitral Valve; Phosphorus; Prosthesis Failure | 1993 |
Proteins and bioprosthetic calcification in the rat model.
Topics: Animals; Bioprosthesis; Calcinosis; Calcium; Calcium-Binding Proteins; Female; Heart Valve Prosthesis; Male; Phosphorus; Prosthesis Failure; Rats; Rats, Wistar; Surface Properties | 1996 |
Severe osteolysis after third-body wear due to hydroxyapatite particles from acetabular cup coating.
Topics: Acetabulum; Aged; Aged, 80 and over; Arthroplasty, Replacement, Hip; Biocompatible Materials; Calcium; Carbon; Chromium Alloys; Durapatite; Electron Probe Microanalysis; Female; Femur; Femur Head; Follow-Up Studies; Foreign-Body Migration; Hip Prosthesis; Humans; Incidence; Male; Microscopy, Electron, Scanning; Middle Aged; Osteolysis; Oxygen; Phosphorus; Polyethylenes; Prosthesis Design; Prosthesis Failure; Radiography; Reoperation; Surface Properties | 1998 |
In vitro testing of bioprostheses: influence of mechanical stresses and lipids on calcification.
Topics: Aortic Valve; Barbital; Bioprosthesis; Buffers; Calcinosis; Calcium; Coloring Agents; Forecasting; Heart Valve Prosthesis; Holography; Humans; Interferometry; Light; Lipids; Materials Testing; Microradiography; Phosphorus; Prosthesis Design; Prosthesis Failure; Quality Control; Stress, Mechanical; Surface Properties | 1998 |