phosphatidylethanol has been researched along with Substance-Withdrawal-Syndrome* in 2 studies
2 other study(ies) available for phosphatidylethanol and Substance-Withdrawal-Syndrome
Article | Year |
---|---|
Alcohol Biomarker Phosphatidylethanol as a Predictor of the Severity of Alcohol Withdrawal Syndrome.
to investigate the relationship between phosphatidylethanol (PEth) and withdrawal severity in patients with alcohol use disorder (AUD).. in 34 patients with AUD admitted for treatment of acute alcohol withdrawal, data were available for initial blood PEth concentrations and scores throughout detoxification of symptoms of withdrawal assessed by trained medical staff using the alcohol withdrawal syndrome (AWS)-scale, a validated scale consisting of 11 items in the alcohol withdrawal syndrome (two subscales with seven physiological and five psychological symptoms).. a significant positive correlation between PEth and the severity of alcohol withdrawal was found. When the sample was divided into two groups, according to whether or not AWS score at some point in the treatment reached 6 or more, the median PEth score was higher in those whose peak score had been 6 or more (score of 6 being the suggested cutoff to start medicating the withdrawal syndrome). Although there was a trend for some aspects of the clinical history to be more 'severe' in those with higher AWS, no differences reached significance.. blood PEth on admission could have a role in identifying patients at risk of more severe AWS. Topics: Alcohol Drinking; Alcoholism; Biomarkers; Ethanol; Glycerophospholipids; Humans; Substance Withdrawal Syndrome | 2023 |
Quantification of phosphatidylethanol 16:0/18:1, 18:1/18:1, and 16:0/16:0 in venous blood and venous and capillary dried blood spots from patients in alcohol withdrawal and control volunteers.
Phosphatidylethanol species (PEths) are promising biomarkers of alcohol consumption. Here, we report on the set-up, validation, and application of a novel UHPLC-ESI-MS/MS method for the quantification of PEth 16:0/18:1, PEth 18:1/18:1, and PEth 16:0/16:0 in whole blood (30 μL) and in venous (V, 30 μL) or capillary (C, 3 punches (3 mm)) dried blood spots (DBS). The methods were linear from 10 (LLOQ) to 2000 ng/mL for PEth 16:0/18:1, from 10 (LLOQ) to 1940 ng/mL for PEth 18:1/18:1, and from 19 (LLOQ) to 3872 ng/mL for PEth 16:0/16:0. Extraction efficiencies were higher than 55% (RSD < 18%) and matrix effects compensated for by IS were between 77 and 125% (RSD < 10%). Accuracy, repeatability, and intermediate precision fulfilled acceptance criteria (bias and RSD below 13%). Validity of the procedure for determination of PEth 16:0/18:1 in blood was demonstrated by the successful participation in a proficiency test. The quantification of PEths in C-DBS was not significantly influenced by the hematocrit, punch localization, or spot volume. The stability of PEths in V-DBS stored at room temperature was demonstrated up to 6 months. The method was applied to authentic samples (whole blood, V-DBS, and C-DBS) from 50 inpatients in alcohol withdrawal and 50 control volunteers. Applying a cut-off value to detect inpatients at 221 ng/mL for PEth 16:0/18:1 provided no false positive results and a good sensitivity (86%). Comparison of quantitative results (Bland-Altman plot, Passing-Bablok regression, and Wilcoxon signed rank test) revealed that V-DBS and C-DBS were valid alternatives to venous blood for the detection of alcohol consumption. Topics: Adult; Aged; Alcohol Drinking; Biomarkers; Chromatography, High Pressure Liquid; Dried Blood Spot Testing; Female; Glycerophospholipids; Humans; Male; Middle Aged; Substance Withdrawal Syndrome; Tandem Mass Spectrometry; Volunteers | 2016 |