nitinol and Ventricular-Fibrillation

nitinol has been researched along with Ventricular-Fibrillation* in 3 studies

Other Studies

3 other study(ies) available for nitinol and Ventricular-Fibrillation

ArticleYear
Early complication after hybrid thoracic aortic aneurysm repair.
    Interactive cardiovascular and thoracic surgery, 2008, Volume: 7, Issue:3

    This brief report describes an unusual hybrid approach complication of aortic arch disease. An acute stent kinking in the first post-operative day promoted ventricular fibrillation and death. Adequate oversizing was achieved and intraoperative angiogram showed no proximal or distal leaks. Unfavorable outcomes are highly under-reported and describing complications are a key instrument to improve this technique.

    Topics: Alloys; Anastomosis, Surgical; Aortic Aneurysm, Thoracic; Blood Vessel Prosthesis; Blood Vessel Prosthesis Implantation; Fatal Outcome; Foreign-Body Migration; Humans; Male; Middle Aged; Polyethylene Terephthalates; Prosthesis Design; Prosthesis Failure; Stents; Sternum; Time Factors; Tomography, X-Ray Computed; Treatment Outcome; Ventricular Fibrillation

2008
Ventricular fibrillation after insertion of a self-expanding metallic stent for malignant dysphagia.
    The American journal of gastroenterology, 2000, Volume: 95, Issue:3

    Topics: Adenocarcinoma; Aged; Alloys; Deglutition Disorders; Equipment Failure Analysis; Esophageal Neoplasms; Esophageal Stenosis; Fatal Outcome; Humans; Male; Palliative Care; Stents; Ventricular Fibrillation

2000
Transvenous closure of secundum atrial septal defects: preliminary results with a new self-expanding nitinol prosthesis in a swine model.
    Circulation, 1997, Apr-15, Volume: 95, Issue:8

    Our purpose was to evaluate a new prosthesis for percutaneous closure of secundum atrial septal defects (ASDs).. Percutaneous closure of surgically created fossa ovalis ASD was attempted in 15 minipigs. The mean balloon-stretched ASD diameter was 12.3+/-2.3 mm (range, 10 to 16 mm). The self-expanding prosthesis was braided from 0.005-in Nitinol wires in the shape of two flat buttons with a short connecting waist with a diameter corresponding to that of the defect to be closed. Polyester filling was added to enhance thrombogenicity. Pulmonary arteriography with levo-phase was obtained before placement; immediately after placement; and at 1-week, 1-month, and 3-month follow-ups. Four animals were killed at 1 week, 1 month, and 3 months for histopathological correlation. Three deaths resulted from ventricular fibrillation (one during anesthesia and two during the placement procedure). Successful placement of the prosthesis was achieved in the remaining 12 animals. Overall immediate ASD closure on angiography occurred in 7 of 12 animals (all polyester-filled prostheses). Absent or trace shunt by angiography was present in 11 of 12 devices at 1 week, with the remaining one demonstrating a small shunt. All septal defects were completely closed at 1 month with the exception of one case in which delayed partial dislodgment of an undersized prosthesis into the right atrium had developed. Closure rate at 3 months was 100%. Neoendothelialization and fibrous incorporation of the prosthesis were completed within 1 to 3 months.. Effective and permanent occlusion of secundum ASDs is feasible with a device that offers the advantages of easy placement, self-centering, and repositionability.

    Topics: Alloys; Animals; Cardiac Catheterization; Endocardium; Femoral Vein; Foreign-Body Migration; Heart Septal Defects, Atrial; Jugular Veins; Postoperative Complications; Prostheses and Implants; Prosthesis Design; Swine; Swine, Miniature; Ventricular Fibrillation; Wound Healing

1997