nitinol has been researched along with Obesity* in 2 studies
2 other study(ies) available for nitinol and Obesity
Article | Year |
---|---|
A Novel Full Sense Device to Treat Obesity in a Porcine Model: Preliminary Results.
To evaluate the technical feasibility, safety, and efficacy of a novel full sense device (FSD) for the treatment of obesity in a porcine model.. The novel FSD comprised a self-expanding metallic esophageal stent connected to a star-shaped nitinol disk. Three types of FSD were used: fully covered (type A), fully covered with barbs (type B), and uncovered with barbs (type C). Nine juvenile pigs were divided into two groups: FSD (n = 6) and control (n = 3). FSD type A was placed in the FSD group. In case of migration, either FSD type B or type C was then randomly placed. Food intake was monitored daily. Weight changes and ghrelin hormone levels were monitored weekly for 12 weeks.. FSD placement was technically successful in all pigs. All FSDs except one migrated to the stomach within 1 week after placement. The pig in which the FSD was retained showed decreased food intake in the first week after FSD placement, and there was a difference in the final weight between the FSD pig and control pigs. The percentage of weight gain was 116.6% in the control group and 105.3% in the FSD pig.. FSD placement under fluoroscopic and endoscopic guidance is technically feasible and safe in a porcine model. The uncovered FSD appears to decrease food intake and reduce the rate of weight gain. However, the high FSD migration rate is not encouraging. Topics: Alloys; Animals; Eating; Endoscopy; Feasibility Studies; Fluoroscopy; Foreign-Body Migration; Obesity; Prosthesis Design; Prosthesis Failure; Prosthesis Implantation; Random Allocation; Satiation; Stents; Stomach; Swine; Treatment Outcome; Weight Gain | 2019 |
Thermoreactive clips do not reduce sternal infection: a propensity-matched comparison with sternal wires.
Sternal stability is essential to prevent serious infective complications after sternotomy. This paper examines whether nitinol thermoreactive clips reduce sternal wound infection rates in obese patients [body mass index (BMI) ≥30] compared with sternal wires.. All patients with BMI ≥30 undergoing cardiac surgery via median sternotomy between February 2008 and February 2013 in our institution were divided into two groups depending on sternal closure technique-sternal wires or thermoreactive clips. Comparison was made using propensity-matched analysis with sternal wound infection as the primary outcome.. Of 1371 patients, 826 (60%) had thermoreactive clips and 545 (40%) sternal wires. The sternal wires group was older (mean age 66.62 ± 10.1 vs 64.35 ± 9.8 years, P = 0.00) with a greater proportion of females (39 vs 26%, P = 0.00). In unmatched group comparison, both superficial sternal wound infection (thermoreactive clips 4% vs wires 3%) and deep infection (thermoreactive clips 3% vs wires 0.6%, P = 0.00) were more common in the thermoreactive clips group. More patients in the thermoreactive clips group required debridement and a larger number had vacuum-assisted closure [thermoreactive clips 10 patients (1%) vs sternal wires 2 (0.4%)]. Propensity-matching yielded two groups of 356 patients. There was no difference in sternal wound infection rates [thermoreactive clips 19 patients (5%) vs sternal wires 15 (4%), P = 0.58] or deep sternal infection rates [thermoreactive clips 9 patients (3%) vs sternal wires 3 (1%), P = 0.11].. Thermoreactive clips did not have an advantage in the prevention of superficial or deep sternal wound infection in obese patients undergoing sternotomy. Topics: Aged; Alloys; Biocompatible Materials; Bone Wires; Cardiovascular Diseases; Female; Humans; Male; Middle Aged; Obesity; Propensity Score; Reoperation; Sternotomy; Sternum; Surgical Instruments; Surgical Wound Infection; Treatment Outcome; Wound Closure Techniques | 2015 |