nitinol and Hearing-Loss--Sensorineural

nitinol has been researched along with Hearing-Loss--Sensorineural* in 1 studies

Other Studies

1 other study(ies) available for nitinol and Hearing-Loss--Sensorineural

ArticleYear
Comparison of hearing results of nitinol SMART stapes piston prosthesis with conventional piston prostheses: postoperative results of nitinol stapes prosthesis.
    Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology, 2007, Volume: 28, Issue:5

    Recently, a new stapedotomy piston prosthesis, which is a composite metal alloy of nickel and titanium known as nitinol, has been introduced into medical use. This biocompatible alloy has the unique property of shape-memory, which permits tight self-crimping when heat is applied to the wire. To substantiate the favorable initial observations with the SMART piston, this study was undertaken to compare these results (n=26) with those obtained using conventional stainless steel or platinum ribbon prostheses (n=28).. Prospective consecutive case review: consecutive cases performed by the same surgeon were analyzed.. Tertiary referral center.. Fifty-four healthy patients with otosclerosis.. Stapedotomy using either SMART prosthesis or conventional prosthesis.. Hearing outcomes by audiological assessment.. The postoperative hearing mean pure-tone average was 24.81+/-16.20 dBHL for Group 1 (SMART prosthesis) and 27.46+/-15.57 dBHL for Group 2 (conventional prosthesis). Postoperative mean air-bone gap was 7.07+/-8.14 dBHL for Group 1 and 6.38+/-7.54 dBHL for Group 2 using 0.5-, 1-, 2-, and 4-kHz frequencies. When analyzed according to the American Academy of Otolaryngology-Head & Neck Surgery reporting criteria using an estimate of 3 kHz as a mean of the 2-and 4-kHz values, the postoperative mean air-bone gap was 5.42+/-5.4 dBHL for Group 1 SMART and 5.98+/-5.47 dBHL for Group 2 conventional prostheses. Postoperative speech discrimination scores were 96%+/-8.64% and 97%+/-5.9%, respectively. These differences were not shown to be statistically different.. Results demonstrate that experienced surgeons may achieve comparable results with both prostheses; however, the ease of self-crimping and the tightness of the crimp may provide advantages that may have long-term benefits. The potential issue of nickel allergy is important when considering patients for this prosthesis.

    Topics: Adult; Aged; Alloys; Audiometry, Pure-Tone; Cochlear Implants; Evoked Potentials, Auditory, Brain Stem; Female; Hearing Loss, Sensorineural; Humans; Male; Middle Aged; Otosclerosis; Postoperative Care; Prospective Studies; Prosthesis Design; Prosthesis Implantation; Severity of Illness Index; Stapes Surgery; Stents

2007