nitinol has been researched along with Emergencies* in 2 studies
2 other study(ies) available for nitinol and Emergencies
Article | Year |
---|---|
Curved nitinol stent-graft placement for treating blunt thoracic aortic injury: an early experience.
Blunt trauma-induced aortic injury traditionally has been treated with early open surgical repair. However, recently endovascular stent-graft technology is considered a less-invasive therapeutic alternative, and flexible stent-grafts, such as the Matsui-Kitamura stent-graft (MKSG), are being used widely. We report our experience with the curved MKSG in treating thoracic aortic injuries.. Nine patients with traumatic thoracic aortic injury underwent endovascular surgery (8, emergency; 1, elective) with curved MKSG. The study variables were Injury Severity Score, endovascular surgery duration, aortic and stent-graft diameter, stay in the intensive care unit, follow-up period, and mortality. An MKSG was constructed using the Matsui-Kitamura stent and a polyester fabric graft. The stent-graft was placed using the transfemoral approach and the wire-tug technique.. The mean Injury Severity Score was 42.3; 5 patients required 6 emergency procedures before the endovascular procedure (pneumothorax or hemothorax drainage, 5; transarterial embolization, 1). In 8 patients (88.9%), we achieved complete pseudoaneurysm exclusion or hemostasis in the injured portion. There were no postoperative complications; blood loss was minimal, and the intensive care unit stay was 13.4 days. The overall hospital mortality was 22.2% (n = 2; causes of death were unrelated to MKSG placement). Neither intervention-related mortality during follow-up (mean, 237.7 days) nor late endovascular graft-related complications (endoleak or graft migration) were noted.. Although this study is limited by a small sample size and short follow-up period, no collapse or stent-graft fractures were noted. Thus, MKSG placement for traumatic thoracic aortic injury appears a safe and effective therapy. Topics: Adult; Aged; Alloys; Aneurysm, False; Aorta, Thoracic; Blood Vessel Prosthesis; Elective Surgical Procedures; Emergencies; Equipment Design; Hemostasis, Endoscopic; Humans; Middle Aged; Prosthesis Design; Stents; Wounds, Nonpenetrating | 2008 |
Surgical interventions after emergency endovascular stent-grafting for acute type B aortic dissections.
In this retrospective study we reviewed our results of secondary surgery for complications after emergency placement of aortic stents for acute type B dissection. From October 2000 to June 2006, endovascular stent-grafting (ESG) was performed in 13 patients as an emergency procedure for acute type B dissection. Self-expanding nitinol stents (mean diameter 39.8+/-4.7 mm) were placed into the descending aorta distal to the left subclavian artery. In-hospital mortality was 15.4% (2/13) and related to persistent visceral malperfusion. Three patients (23%) required consecutive open surgery of the thoracic aorta after emergency endovascular stent-grafting for acute type B dissection. Indications for surgery included acute development of retrograde type A aortic dissection and acute stent dislocation by fractured wires and secondary leakage. Elective surgery was necessary in one patient 6 months after stent-grafting for late formation of an aneurysm of the descending aorta. There were no deaths or major morbidity after surgery of the thoracic aorta early or during follow-up. Mean follow-up was 38.0+/-13.9 months (range 1-70 months) and complete. We conclude from our study that stent-grafting of the descending aorta is a feasible, relatively safe and effective approach even in the emergency treatment of patients with complicated acute type B dissection. However, in a relevant number of patients emergency stent-grafting for acute type B aortic dissection results in complications that require secondary surgical treatment. Topics: Aged; Alloys; Aortic Aneurysm, Thoracic; Aortic Dissection; Blood Vessel Prosthesis Implantation; Emergencies; Female; Follow-Up Studies; Humans; Male; Middle Aged; Retrospective Studies; Stents; Tomography, X-Ray Computed; Treatment Outcome | 2007 |