A novel device for atrial septal defect occlusion (GORE CARDIOFORM).
The GORE CARDIOFORM atrial septal defect (ASD) Occluder (GCA) is composed of a platinum-filled nitinol wire frame covered with expanded polytetrafluoroethylene, making it softer and more conformable compared with nitinol mesh devices. After the ASSURED clinical study confirmed the efficacy and safety of the device, it received U.S. Food and Drug Administration approval and a European conformity mark. Our aim was to understand the learning curve implicated in using the GCA for ASD closure in paediatric and adult patients as well as to study the early outcomes. To this end, a review of ASD device closures with GCA in 4 UK centres was conducted between January 2020 and January 2023. Implantation success was the primary outcome; the secondary outcomes were serious adverse events, including new onset arrhythmia. In all, 135 patients were included, and 128 (95%) had successful ASD device closure with GCA. The median patient age was 49 years, the median defect size was 18 mm, and the median device size was 37 mm. The median follow-up time was 6 months (interquartile range 1-14). One device embolisation occurred, and 15 patients (12% of GCA implantations) developed new onset arrhythmia - this was not related to patient age, defect diameter or device oversizing but was positively associated with device size. With growing experience using GCA, the device can be applied to a wide variety of ASD sizes and morphologies. Given the number of successful implantations with an absence of aortic erosion, as well as the ability to perforate through the device should procedures be required in the left atrium, the GCA device is an important addition for interventionists who close atrial septal defects. Topics: Adult; Arrhythmias, Cardiac; Cardiac Catheterization; Child; Heart Septal Defects, Atrial; Humans; Middle Aged; Prosthesis Design; Septal Occluder Device; Time Factors; Treatment Outcome | 2023 |
1 trial(s) available for nitinol and Arrhythmias--Cardiac
Article | Year |
---|---|
Transcatheter closure of perimembranous ventricular septal defect using a novel fully bioabsorbable occluder: multicenter randomized controlled trial.
Although the use of bioabsorbable occluder is expected to reduce the risk of metal occluder-related complications, it has not been approved due to incomplete degradation and new complications. Novel fully bioabsorbable occluders were designed to overcome such limitations. The aim of this study was to investigate the efficacy and safety of a fully biodegradable occluder in patients with ventricular septal defects. 125 patients with perimembranous ventricular septal defect (VSD) larger than 3 mm were screened from April 2019 to January 2020 in seven centers. 108 patients were enrolled and randomized into the bioabsorbable occluder group (n = 54 patients) and nitinol occluder group (n = 54). A non-inferiority design was utilized and all patients underwent transcatheter device occlusion. Outcomes were analyzed with a 24-month follow-up. All patients were successfully implanted and completed the trial. No residual shunt >2 mm was observed during follow-up. Transthoracic echocardiography showed a hyperechoic area corresponding to the bioabsorbable occluder which decreased primarily during the first year after implantation and disappeared within 24 months. Postprocedural arrhythmia was the only occluder-related complication with an incidence of 5.56% and 14.81% for the bioabsorbable and nitinol groups, respectively (P = 0.112). The incidence of sustained conduction block was lower in the bioabsorbable occluder group (0/54 vs. 6/54, P = 0.036) at 24-month follow-up. In conclusion, the novel fully bioabsorbable occluder can be successfully and safely implanted under echocardiography guidance and reduce the incidence of sustained postprocedural arrythmia. The efficacy and safety of this fully biodegradable occluder are non-inferior to that of a traditional nitinol one. Topics: Absorbable Implants; Arrhythmias, Cardiac; Cardiac Catheterization; Echocardiography; Heart Septal Defects, Ventricular; Humans | 2023 |
1 other study(ies) available for nitinol and Arrhythmias--Cardiac
Article | Year |
---|---|
Initial clinical experience with the GORE
To report the initial clinical experience with a novel atrial septal defect (ASD) closure device, the GORE. Transcatheter closure has become the treatment of choice for secundum ASD. A wide range of occluder devices are available, but concern has been raised about the risk of cardiac erosion associated with rigid devices and future access to the left atrium METHODS: Retrospective chart review of patients treated with the GCO at three Canadian centers. Primary outcomes were procedural success and residual shunting at follow-up, as well as 30-day major adverse events. Secondary outcomes included new onset atrial arrhythmias, wire frame fractures (WFF), and all cause mortality. Clinical, echocardiographic, procedural data, and follow-up outcome variables were collected in each participating hospital.. Between February and December 2015, 26 patients (5 children and 21 adults) underwent transcatheter ASD closure with the GCO and were included in the study cohort. Procedural success was achieved in 22 of 26 patients (85%) and no major procedural complications were observed. Two patients (8%) presented new onset atrial tachyarrhythmia during early follow-up (0-30 days). Follow-up echocardiography (median of 119 days [IQR: 92-146]) demonstrated no residual shunt in all implanted patients. After a median clinical follow-up of 174 days (IQR: 135-239), one patient died of an unrelated cause, there were no documented major adverse cardiovascular events. Fluoroscopic imaging of the device was performed in 20 patients (91%), and WFF was noted in five cases. No clinical consequence or device dysfunction was observed in these patients.. In this first-in-man multicenter study, the GCO was safe and effective for ASD closure, with no major adverse events or residual shunt at follow-up. © 2017 Wiley Periodicals, Inc. Topics: Adolescent; Adult; Alloys; Arrhythmias, Cardiac; Cardiac Catheterization; Child; Child, Preschool; Echocardiography, Doppler, Color; Echocardiography, Transesophageal; Female; Heart Septal Defects, Atrial; Humans; Male; Middle Aged; Ontario; Polytetrafluoroethylene; Prosthesis Design; Quebec; Retrospective Studies; Risk Factors; Septal Occluder Device; Time Factors; Treatment Outcome | 2017 |