Page last updated: 2024-10-19

nickel and Tracheal Stenosis

nickel has been researched along with Tracheal Stenosis in 10 studies

Nickel: A trace element with the atomic symbol Ni, atomic number 28, and atomic weight 58.69. It is a cofactor of the enzyme UREASE.
nickel ion : A nickel atom having a net electric charge.
nickel atom : Chemical element (nickel group element atom) with atomic number 28.

Tracheal Stenosis: A pathological narrowing of the TRACHEA.

Research Excerpts

ExcerptRelevanceReference
"To investigate and treat the late complications of using nickel-titanium alloy stents in laryngotracheal, bronchial, and esophageal stenosis patients who developed severe laryngotracheal stenosis (SLS)."7.78Late complications of nickel-titanium alloy stent in tracheal stenosis. ( Chen, W; Ruan, Y, 2012)
"A new method used in treatment of tracheal stenosis by means of nitinol alloy intraluminal tracheal stent (Ni-Ti ITS) is introduced."7.68[Nitinol alloy endotracheal stent used in treatment of tracheal stenosis: experimental and clinical applications]. ( Liu, Y, 1993)
"To investigate and treat the late complications of using nickel-titanium alloy stents in laryngotracheal, bronchial, and esophageal stenosis patients who developed severe laryngotracheal stenosis (SLS)."3.78Late complications of nickel-titanium alloy stent in tracheal stenosis. ( Chen, W; Ruan, Y, 2012)
"To develop a new prosthesis for treating tracheal stenosis and tracheobronchomalacia, we examined the usefulness of an intratracheal stent made of shape memory alloy (SMA), a titanium-nickel alloy composed of 50% of each metal."3.69[Experimental study of an intratracheal stent made of shape memory alloy]. ( Tsubota, N; Tsugawa, C; Yoshimura, M, 1994)
"A new method used in treatment of tracheal stenosis by means of nitinol alloy intraluminal tracheal stent (Ni-Ti ITS) is introduced."3.68[Nitinol alloy endotracheal stent used in treatment of tracheal stenosis: experimental and clinical applications]. ( Liu, Y, 1993)

Research

Studies (10)

TimeframeStudies, this research(%)All Research%
pre-19900 (0.00)18.7374
1990's3 (30.00)18.2507
2000's4 (40.00)29.6817
2010's3 (30.00)24.3611
2020's0 (0.00)2.80

Authors

AuthorsStudies
Ma, G1
Wang, DF1
Su, QG1
Lou, N1
Zhu, ZW1
Fu, JH1
Xu, MX1
Chen, W2
Ruan, Y1
Knox, GW1
Peng, J1
Song, X1
Zheng, Y1
Hu, G1
Wei, L1
Sun, Y1
Zhu, J1
Zhou, J1
Yi, HJ1
Zhang, BQ1
Liu, W1
Peng, PH1
Shi, XZ1
Zhang, Y1
He, L1
Jiang, H1
Wei, BJ1
Qi, F1
Jiang, ZD1
Zhu, XL1
Ma, ZX1
Li, M1
Huang, YJ1
Gao, X1
Yoshimura, M1
Tsugawa, C1
Tsubota, N1
Liu, Y1

Other Studies

10 other studies available for nickel and Tracheal Stenosis

ArticleYear
[Tracheal stent implantation for the treatment of tumor-induced acute airway stenosis].
    Ai zheng = Aizheng = Chinese journal of cancer, 2008, Volume: 27, Issue:8

    Topics: Adult; Aged; Blood Gas Analysis; Bronchoscopy; Esophageal Neoplasms; Female; Humans; Lung Neoplasms;

2008
Late complications of nickel-titanium alloy stent in tracheal stenosis.
    The Laryngoscope, 2012, Volume: 122, Issue:4

    Topics: Adult; Alloys; Bronchoscopy; Female; Follow-Up Studies; Humans; Male; Middle Aged; Nickel; Plastic S

2012
In response to Late complications of nickel-titanium alloy stent in tracheal stenosis.
    The Laryngoscope, 2013, Volume: 123, Issue:2

    Topics: Female; Humans; Male; Nickel; Plastic Surgery Procedures; Stents; Titanium; Tracheal Stenosis; Trach

2013
In reference to late complications of nickel-titanium alloy stent in tracheal stenosis.
    The Laryngoscope, 2013, Volume: 123, Issue:2

    Topics: Female; Humans; Male; Nickel; Plastic Surgery Procedures; Stents; Titanium; Tracheal Stenosis; Trach

2013
[The treatment of stricture of larynx and trachea with Ni-Ti shape memory alloy stand].
    Zhonghua er bi yan hou ke za zhi, 1999, Volume: 34, Issue:6

    Topics: Adult; Aged; Female; Follow-Up Studies; Humans; Laryngostenosis; Male; Middle Aged; Nickel; Stents;

1999
[A study on the application of Nickle-Titanium alloys stent for prevention and treatment tracheostomal stenosis after total laryngectomy].
    Lin chuang er bi yan hou ke za zhi = Journal of clinical otorhinolaryngology, 2003, Volume: 17, Issue:8

    Topics: Adult; Aged; Female; Humans; Laryngectomy; Male; Middle Aged; Nickel; Postoperative Complications; S

2003
[Forty-three tracheal stricture with Ni-Ti shape memory alloy stent].
    Zhonghua er bi yan hou tou jing wai ke za zhi = Chinese journal of otorhinolaryngology head and neck surgery, 2005, Volume: 40, Issue:4

    Topics: Adult; Aged; Aged, 80 and over; Female; Humans; Male; Middle Aged; Neck; Nickel; Retrospective Studi

2005
[Treatment of serious tracheal and esophagus narrow with nickel-titanium stand].
    Zhonghua er bi yan hou tou jing wai ke za zhi = Chinese journal of otorhinolaryngology head and neck surgery, 2005, Volume: 40, Issue:2

    Topics: Adult; Aged; Esophageal Stenosis; Female; Humans; Male; Middle Aged; Nickel; Stents; Titanium; Trach

2005
[Experimental study of an intratracheal stent made of shape memory alloy].
    [Zasshi] [Journal]. Nihon Kyobu Geka Gakkai, 1994, Volume: 42, Issue:11

    Topics: Alloys; Animals; Nickel; Rabbits; Stents; Titanium; Tracheal Stenosis

1994
[Nitinol alloy endotracheal stent used in treatment of tracheal stenosis: experimental and clinical applications].
    Zhonghua wai ke za zhi [Chinese journal of surgery], 1993, Volume: 31, Issue:5

    Topics: Adult; Alloys; Animals; Dogs; Female; Humans; Male; Nickel; Stents; Titanium; Tracheal Stenosis

1993