Page last updated: 2024-10-19

nickel and Prosthesis Durability

nickel has been researched along with Prosthesis Durability in 40 studies

Nickel: A trace element with the atomic symbol Ni, atomic number 28, and atomic weight 58.69. It is a cofactor of the enzyme UREASE.
nickel ion : A nickel atom having a net electric charge.
nickel atom : Chemical element (nickel group element atom) with atomic number 28.

Research Excerpts

ExcerptRelevanceReference
" Other delayed complications include nickel allergy, cardiac conduction abnormalities, valvular damage, and device endocarditis."4.93Long-term Complications After Transcatheter Atrial Septal Defect Closure: A Review of the Medical Literature. ( Baruteau, AE; Boudjemline, Y; Hascoet, S; Iriart, X; Jalal, Z; Kreitmann, B; Thambo, JB, 2016)
" A delayed hypersensitivity reaction type IV to nickel (Ni), chromium (Cr), or cobalt (Co) has been suggested to play a role in its aetiology."3.76Lymphocyte proliferation responses in patients with pseudotumors following metal-on-metal hip resurfacing arthroplasty. ( Beard, D; Gill, HS; Kwon, YM; Murray, DW; Pandit, H; Summer, B; Taylor, A; Thomas, P, 2010)
"Metal hypersensitivity is an uncommon complication of knee arthroplasty that can lead to significant functional impairment and aseptic prosthesis failure."1.48Failure of a Medial Unicompartmental Knee Replacement due to Metal Allergy. ( Apostolopoulos, AP; Balfousias, T; Khan, S; Srikanth, B; Tselentakis, G, 2018)
"Metal allergy is an uncommon and poorly understood cause of failure of orthopedic implants."1.46Metal Allergy as a Cause of Implant Failure in Shoulder Arthroplasty. ( Getz, C; Hoffler, CE; Ko, JK; Nicholson, TA; Williams, G, 2017)
"The major cause of ARMD was not type IV hypersensitivity in the remaining nine patients."1.43Immune response in adverse reactions to metal debris following metal-on-metal total hip arthroplasty. ( Hasegawa, M; Iino, T; Sudo, A, 2016)
"No chromium(VI) release was detected."1.40Failure of total hip implants: metals and metal release in 52 cases. ( Bregnbak, D; Jakobsen, SS; Jellesen, MS; Johansen, JD; Lidén, C; Lundgren, L; Menné, T; Møller, P; Søballe, K; Thyssen, JP, 2014)
"40."1.37Use of a segmental thermoexpandable metal alloy stent in the management of malignant ureteric obstruction: a single centre experience in the UK. ( Bach, C; Buchholz, N; Junaid, I; Masood, J; Moraitis, K; Poullis, C; Zaman, F, 2011)
"The clinical relevance of metal allergy in the differential diagnosis is often unclear and patients may even tolerate implants containing metals to which they are allergic."1.35Intolerance reactions to knee arthroplasty in patients with nickel/cobalt allergy and disappearance of symptoms after revision surgery with titanium-based endoprostheses. ( Dietrich, KA; Mazoochian, F; Reinert, M; Ruzicka, T; Summer, B; Thomas, P, 2009)

Research

Studies (40)

TimeframeStudies, this research(%)All Research%
pre-19901 (2.50)18.7374
1990's4 (10.00)18.2507
2000's14 (35.00)29.6817
2010's20 (50.00)24.3611
2020's1 (2.50)2.80

Authors

AuthorsStudies
Zmerly, H1
Moscato, M1
Mancuso, V1
Di Gregori, V1
Chen, L1
Zhang, Y1
Pacheco, K1
Dai, S1
Ko, JK1
Nicholson, TA1
Hoffler, CE1
Williams, G1
Getz, C1
Wolff, M1
Haasper, C1
Zahar, A1
Gauck, C1
Gehrke, T1
Citak, M1
Ayers, R1
Miller, M1
Schowinsky, J1
Burger, E1
Patel, V1
Kleck, C1
Sessa, G1
Testa, G1
Gioitta Iachino, S1
Costarella, L1
Puma Pagliarello, C1
Ferrante, M1
Grasso, A1
Pavone, V1
Delimar, D1
Bohaček, I1
Paštar, Z1
Lipozenčić, J1
Samelko, L1
Caicedo, MS2
Jacobs, J1
Hallab, NJ2
Apostolopoulos, AP1
Balfousias, T1
Khan, S1
Srikanth, B1
Tselentakis, G1
Lohmann, CH1
Meyer, H1
Nuechtern, JV1
Singh, G1
Junk-Jantsch, S1
Schmotzer, H1
Morlock, MM1
Pflüger, G1
Jakobsen, SS2
Lidén, C1
Søballe, K2
Johansen, JD2
Menné, T2
Lundgren, L1
Bregnbak, D1
Møller, P1
Jellesen, MS1
Thyssen, JP2
Novak, CC1
Hsu, AR1
Della Valle, CJ1
Skipor, AK1
Campbell, P1
Amstutz, HC1
Jiranek, WA1
Onyike, A1
Pombar, XF1
Jacobs, JJ2
Liu, J1
Shang, L1
Liu, JY1
Qin, CY1
Petrini, L1
Trotta, A1
Dordoni, E1
Migliavacca, F1
Dubini, G1
Lawford, PV1
Gosai, JN1
Ryan, DM1
Testi, D1
Pennati, G1
Nagaraja, S1
Di Prima, M1
Saylor, D1
Takai, E1
Jalal, Z1
Hascoet, S1
Baruteau, AE1
Iriart, X1
Kreitmann, B1
Boudjemline, Y1
Thambo, JB1
Hasegawa, M1
Iino, T1
Sudo, A1
Dahlstrand, H1
Stark, A1
Anissian, L1
Hailer, NP1
Desai, R1
McAllister, K1
Reddy, A1
Dietrich, KA2
Mazoochian, F2
Summer, B2
Reinert, M1
Ruzicka, T1
Thomas, P5
Kwon, YM1
Pandit, H1
Taylor, A1
Beard, D1
Murray, DW1
Gill, HS1
Engkilde, K1
Eben, R1
Nerz, C1
Schneider, S1
Schuh, A2
Banke, IJ1
Kromka-Szydek, M1
Jedrusik-Pawłowska, M1
Milewski, G1
Lekston, Z1
Cieślik, T1
Drugacz, J1
Zaman, F1
Poullis, C1
Bach, C1
Moraitis, K1
Junaid, I1
Buchholz, N1
Masood, J1
Williams, S1
Tipper, JL1
Ingham, E1
Stone, MH1
Fisher, J1
Kachler, W1
Göske, J1
Wagner, L1
Holzwarth, U1
Forst, R1
Peña, J1
Solano, E1
Mendoza, A1
Casals, J1
Planell, JA1
Gil, FJ1
Klarskov, P1
Nordling, J1
Nielsen, JB1
Kim, JW1
Ahn, SJ1
Chang, YI1
Cioffi, M1
Gilliland, D1
Ceccone, G1
Chiesa, R1
Cigada, A1
Yokoyama, K1
Ogawa, T1
Fujita, A1
Asaoka, K1
Sakai, J1
Anwar, HA1
Aldam, CH1
Visuvanathan, S1
Hart, AJ1
Rau, C1
Thomsen, M1
Gawkrodger, DJ1
Besimo, C1
Maurer, TB1
Ochsner, PE1
Schwarzer, G1
Schumacher, M1
Brien, WW1
Salvati, EA2
Betts, F2
Bullough, P1
Wright, T2
Rimnac, C1
Buly, R1
Garvin, K1
Boskey, A1
Bansal, M1
Wirz, J1
Jäger, K1
Schmidli, F1

Clinical Trials (1)

Trial Overview

TrialPhaseEnrollmentStudy TypeStart DateStatus
Study of Tolerance and Effectiveness of Ureteral Stents MEMOKATH ® 051 in the Treatment of Chronic Strictures of the Ureter[NCT00790686]Phase 213 participants (Actual)Interventional2008-11-30Completed
[information is prepared from clinicaltrials.gov, extracted Sep-2024]

Reviews

4 reviews available for nickel and Prosthesis Durability

ArticleYear
Orthopedic and Cutaneous Reactions to Nickel after Total Hip Replacement.
    Acta dermatovenerologica Croatica : ADC, 2018, Volume: 26, Issue:1

    Topics: Aged; Arthroplasty, Replacement, Hip; Dermatitis, Allergic Contact; Female; Humans; Hypersensitivity

2018
A Computational Approach for the Prediction of Fatigue Behaviour in Peripheral Stents: Application to a Clinical Case.
    Annals of biomedical engineering, 2016, Volume: 44, Issue:2

    Topics: Alloys; Computer Simulation; Equipment Failure Analysis; Humans; Male; Middle Aged; Models, Cardiova

2016
Long-term Complications After Transcatheter Atrial Septal Defect Closure: A Review of the Medical Literature.
    The Canadian journal of cardiology, 2016, Volume: 32, Issue:11

    Topics: Aortic Valve Insufficiency; Arrhythmias, Cardiac; Atrioventricular Block; Cardiac Catheterization; E

2016
Nickel sensitivity and the implantation of orthopaedic prostheses.
    Contact dermatitis, 1993, Volume: 28, Issue:5

    Topics: Dermatitis, Allergic Contact; Hip Prosthesis; Humans; Nickel; Prostheses and Implants; Prosthesis Fa

1993

Trials

1 trial available for nickel and Prosthesis Durability

ArticleYear
Elevated serum concentrations of cobalt, chromium, nickel, and manganese after metal-on-metal alloarthroplasty of the hip: a prospective randomized study.
    The Journal of arthroplasty, 2009, Volume: 24, Issue:6

    Topics: Adult; Aged; Arthroplasty, Replacement, Hip; Chromium; Cobalt; Female; Follow-Up Studies; Hip Joint;

2009

Other Studies

35 other studies available for nickel and Prosthesis Durability

ArticleYear
Two-Stage Revision Total Knee Arthroplasty for Suspected Periprosthetic Joint Infection and Metal and Bone Cement Hypersensitivity.
    Journal of population therapeutics and clinical pharmacology = Journal de la therapeutique des populations et de la pharmacologie clinique, 2019, Dec-23, Volume: 26, Issue:3

    Topics: Aged; Arthroplasty, Replacement, Knee; Bone Cements; Female; Humans; Hypersensitivity; Methylmethacr

2019
The T Cell Repertoires from Nickel Sensitized Joint Implant Failure Patients.
    International journal of molecular sciences, 2021, Feb-28, Volume: 22, Issue:5

    Topics: Female; Haptens; Humans; Hypersensitivity; Joint Prosthesis; Nickel; Prosthesis Failure; Receptors,

2021
Metal Allergy as a Cause of Implant Failure in Shoulder Arthroplasty.
    Orthopedics, 2017, Sep-01, Volume: 40, Issue:5

    Topics: Aged; Arthroplasty, Replacement, Shoulder; Chromium; Cobalt; Female; Humans; Hypersensitivity; Male;

2017
Severe metallosis and elevated chromium in serum following implantation of the joint unloading implant system.
    Archives of orthopaedic and trauma surgery, 2017, Volume: 137, Issue:12

    Topics: Arthroplasty, Replacement, Knee; Bone Screws; Chromium; Cobalt; Humans; Knee Joint; Knee Prosthesis;

2017
Three cases of metallosis associated with spine instrumentation.
    Journal of materials science. Materials in medicine, 2017, Dec-01, Volume: 29, Issue:1

    Topics: Aged; Calcium; Chromium; Cobalt; Corrosion; Female; Humans; Ions; Iron; Lumbar Vertebrae; Male; Mate

2017
Potential presence of metals in patients treated with metal-metal coupling prostheses for hip arthroplasty at 7 and 10 years of follow-up.
    European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2018, Volume: 28, Issue:4

    Topics: Adult; Aged; Aged, 80 and over; Arthroplasty, Replacement, Hip; Chromium; Cobalt; Female; Hip Prosth

2018
Transition from metal-DTH resistance to susceptibility is facilitated by NLRP3 inflammasome signaling induced Th17 reactivity: Implications for orthopedic implants.
    PloS one, 2019, Volume: 14, Issue:1

    Topics: Animals; Caspase 1; Cells, Cultured; Cytokines; Female; Humans; Hypersensitivity, Delayed; In Vitro

2019
Failure of a Medial Unicompartmental Knee Replacement due to Metal Allergy.
    Journal of long-term effects of medical implants, 2018, Volume: 28, Issue:4

    Topics: Aged; Arthroplasty, Replacement, Knee; Female; Humans; Hypersensitivity; Knee Prosthesis; Nickel; Pr

2018
Periprosthetic tissue metal content but not serum metal content predicts the type of tissue response in failed small-diameter metal-on-metal total hip arthroplasties.
    The Journal of bone and joint surgery. American volume, 2013, Sep-04, Volume: 95, Issue:17

    Topics: Aged; Arthroplasty, Replacement, Hip; Chromium; Cobalt; Female; Femur; Hip Joint; Hip Prosthesis; Hu

2013
Failure of total hip implants: metals and metal release in 52 cases.
    Contact dermatitis, 2014, Volume: 71, Issue:6

    Topics: Chromium; Cobalt; Corrosion; Hip Prosthesis; Humans; Nickel; Polyethylene; Prosthesis Design; Prosth

2014
Metal ion levels in maternal and placental blood after metal-on-metal total hip arthroplasty.
    American journal of orthopedics (Belle Mead, N.J.), 2014, Volume: 43, Issue:12

    Topics: Adult; Arthroplasty, Replacement, Hip; Chromium; Cobalt; Female; Fetal Blood; Hip Prosthesis; Humans

2014
Newly designed "pieced" stent in a rabbit model of benign esophageal stricture.
    World journal of gastroenterology, 2015, Jul-28, Volume: 21, Issue:28

    Topics: Alloys; Animals; Burns, Chemical; Device Removal; Dilatation; Disease Models, Animal; Esophageal Ste

2015
Current practices in corrosion, surface characterization, and nickel leach testing of cardiovascular metallic implants.
    Journal of biomedical materials research. Part B, Applied biomaterials, 2017, Volume: 105, Issue:6

    Topics: Corrosion; Education; Humans; Nickel; Prosthesis Failure; Stents; United States; United States Food

2017
Immune response in adverse reactions to metal debris following metal-on-metal total hip arthroplasty.
    BMC musculoskeletal disorders, 2016, 05-21, Volume: 17

    Topics: Aged; Aged, 80 and over; Arthroplasty, Replacement, Hip; Chromium; Cobalt; Female; Hip Prosthesis; H

2016
Soluble and particulate Co-Cr-Mo alloy implant metals activate the inflammasome danger signaling pathway in human macrophages: a novel mechanism for implant debris reactivity.
    Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 2009, Volume: 27, Issue:7

    Topics: Carrier Proteins; Caspase 1; Cells, Cultured; Chromium; Cobalt; Humans; Inflammation; Interleukin-1b

2009
Intolerance reactions to knee arthroplasty in patients with nickel/cobalt allergy and disappearance of symptoms after revision surgery with titanium-based endoprostheses.
    Journal der Deutschen Dermatologischen Gesellschaft = Journal of the German Society of Dermatology : JDDG, 2009, Volume: 7, Issue:5

    Topics: Aged; Cobalt; Erythema; Female; Humans; Hypersensitivity; Joint Diseases; Knee Prosthesis; Middle Ag

2009
Lymphocyte proliferation responses in patients with pseudotumors following metal-on-metal hip resurfacing arthroplasty.
    Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 2010, Volume: 28, Issue:4

    Topics: Adult; Aged; Arthroplasty, Replacement, Hip; Chromium; Cobalt; Female; Granuloma, Plasma Cell; Hip J

2010
The association between metal allergy, total hip arthroplasty, and revision.
    Acta orthopaedica, 2009, Volume: 80, Issue:6

    Topics: Adolescent; Adult; Arthroplasty, Replacement, Hip; Case-Control Studies; Child; Chromium; Cobalt; De

2009
[Contact allergy to metals and bone cement components in patients with intolerance of arthroplasty].
    Deutsche medizinische Wochenschrift (1946), 2010, Volume: 135, Issue:28-29

    Topics: Adult; Aged; Aged, 80 and over; Benzoyl Peroxide; Bone Cements; Chromium; Cobalt; Dermatitis, Allerg

2010
Numerical analysis of displacements of mandible bone parts using various elements for fixation of subcondylar fractures.
    Acta of bioengineering and biomechanics, 2010, Volume: 12, Issue:1

    Topics: Biomechanical Phenomena; Bone Plates; Computer Simulation; Fracture Fixation, Internal; Humans; Join

2010
Use of a segmental thermoexpandable metal alloy stent in the management of malignant ureteric obstruction: a single centre experience in the UK.
    Urologia internationalis, 2011, Volume: 87, Issue:4

    Topics: Adult; Aged; Aged, 80 and over; Constriction, Pathologic; Female; Foreign-Body Migration; Humans; Lo

2011
In vitro analysis of the wear, wear debris and biological activity of surface-engineered coatings for use in metal-on-metal total hip replacements.
    Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine, 2003, Volume: 217, Issue:3

    Topics: Cell Survival; Cells, Cultured; Chromium Alloys; Coated Materials, Biocompatible; Coculture Techniqu

2003
[Allergic potential of titanium implants].
    Der Orthopade, 2005, Volume: 34, Issue:4

    Topics: Biocompatible Materials; Humans; Hypersensitivity; Materials Testing; Nickel; Prostheses and Implant

2005
Effect of the M(s) transformation temperature on the wear behaviour of NiTi shape memory alloys for articular prosthesis.
    Bio-medical materials and engineering, 2005, Volume: 15, Issue:4

    Topics: Alloys; Biocompatible Materials; Elasticity; Equipment Failure Analysis; Hardness; Joint Prosthesis;

2005
Experience with Memokath 051 ureteral stent.
    Scandinavian journal of urology and nephrology, 2005, Volume: 39, Issue:2

    Topics: Adult; Aged; Aged, 80 and over; Denmark; Device Removal; Female; Follow-Up Studies; Foreign-Body Mig

2005
Histomorphometric and mechanical analyses of the drill-free screw as orthodontic anchorage.
    American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics, 2005, Volume: 128, Issue:2

    Topics: Animals; Bone Screws; Dental Alloys; Dogs; Male; Mandible; Maxilla; Nickel; Orthodontic Wires; Osseo

2005
Electrochemical release testing of nickel-titanium orthodontic wires in artificial saliva using thin layer activation.
    Acta biomaterialia, 2005, Volume: 1, Issue:6

    Topics: Biomimetic Materials; Corrosion; Diffusion; Electrochemistry; Equipment Failure Analysis; Fluorides;

2005
Fracture of Ni-Ti superelastic alloy under sustained tensile load in physiological saline solution containing hydrogen peroxide.
    Journal of biomedical materials research. Part A, 2007, Sep-01, Volume: 82, Issue:3

    Topics: Alloys; Biocompatible Materials; Corrosion; Hydrogen Peroxide; Materials Testing; Nickel; Prosthesis

2007
The effect of metal ions in solution on bacterial growth compared with wear particles from hip replacements.
    The Journal of bone and joint surgery. British volume, 2007, Volume: 89, Issue:12

    Topics: Arthroplasty, Replacement, Hip; Cobalt; Culture Media; Hip Prosthesis; Humans; Materials Testing; Me

2007
[Metal sensitivity in patients with joint replacement arthroplasties before and after surgery].
    Der Orthopade, 2008, Volume: 37, Issue:2

    Topics: Adult; Aged; Cobalt; Cross-Sectional Studies; Dermatitis, Allergic Contact; Female; Follow-Up Studie

2008
Resin-bonded fixed partial denture technique: results of a medium-term clinical follow-up investigation.
    The Journal of prosthetic dentistry, 1993, Volume: 69, Issue:2

    Topics: Acid Etching, Dental; Adolescent; Adult; Aged; Dental Abutments; Dental Alloys; Dental Cements; Dent

1993
Increased loosening of cemented straight stem prostheses made from titanium alloys. An analysis and comparison with prostheses made of cobalt-chromium-nickel alloy.
    International orthopaedics, 2001, Volume: 25, Issue:2

    Topics: Aged; Alloys; Bone Cements; Chromium; Cobalt; Confidence Intervals; Female; Follow-Up Studies; Hip P

2001
Metal levels in cemented total hip arthroplasty. A comparison of well-fixed and loose implants.
    Clinical orthopaedics and related research, 1992, Issue:276

    Topics: Alloys; Cementation; Chromium; Chromium Alloys; Cobalt; Hip Prosthesis; Humans; Metals; Nickel; Pros

1992
Cobalt-alloy metal debris in periarticular tissues from total hip revision arthroplasties. Metal contents and associated histologic findings.
    Clinical orthopaedics and related research, 1992, Issue:276

    Topics: Adult; Aged; Aged, 80 and over; Chromium; Chromium Alloys; Cobalt; Female; Hip Joint; Hip Prosthesis

1992
[Clinical corrosion. Effect of fissures on an incompatible nonprecious-metal crown alloy].
    Schweizer Monatsschrift fur Zahnmedizin = Revue mensuelle suisse d'odonto-stomatologie = Rivista mensile svizzera di odontologia e stomatologia, 1987, Volume: 97, Issue:9

    Topics: Adult; Corrosion; Crowns; Dental Alloys; Dental Caries; Dental Fissures; Female; Humans; Materials T

1987