metoclopramide has been researched along with Sensitivity and Specificity in 18 studies
Metoclopramide: A dopamine D2 antagonist that is used as an antiemetic.
metoclopramide : A member of the class of benzamides resulting from the formal condensation of 4-amino-5-chloro-2-methoxybenzoic acid with the primary amino group of N,N-diethylethane-1,2-diamine.
Sensitivity and Specificity: Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed)
Excerpt | Relevance | Reference |
---|---|---|
" In this study, we compared the results of noninvasive tests including (1) assay of urinary catecholamines and their metabolites, (2) a provocative pharmacologic test using metoclopramide (MCP test), and (3) 131I-metaiodobenzylguanidine (MIBG) scintigraphy to screen for pheochromocytoma in 10 consecutive patients with an incidentally discovered adrenal mass (6 pheochromocytomas and 4 non-functioning adrenocortical adenomas)." | 9.09 | [Noninvasive screening for pheochromocytoma in patients with an incidentally discovered adrenal mass: usefulness of provocative test with metoclopramide and 131I-metaiodobenzylguanidine scintigraphy]. ( Tsuji, Y; Yokoyama, H, 1999) |
" In this study, we compared the results of noninvasive tests including (1) assay of urinary catecholamines and their metabolites, (2) a provocative pharmacologic test using metoclopramide (MCP test), and (3) 131I-metaiodobenzylguanidine (MIBG) scintigraphy to screen for pheochromocytoma in 10 consecutive patients with an incidentally discovered adrenal mass (6 pheochromocytomas and 4 non-functioning adrenocortical adenomas)." | 5.09 | [Noninvasive screening for pheochromocytoma in patients with an incidentally discovered adrenal mass: usefulness of provocative test with metoclopramide and 131I-metaiodobenzylguanidine scintigraphy]. ( Tsuji, Y; Yokoyama, H, 1999) |
"A feasibility study was conducted to evaluate two biphasic computed tomographic (CT) enterography protocols, a noninvasive CT technique with water administered perorally and CT enteroclysis with methylcellulose administered through a nasojejunal tube, in 23 patients known or suspected to have Crohn disease." | 3.72 | Assessment of small bowel Crohn disease: noninvasive peroral CT enterography compared with other imaging methods and endoscopy--feasibility study. ( Fletcher, JG; Johnson, CD; Sandborn, WJ; Wold, PB, 2003) |
"Metoclopramide has been suggested to relieve this, but two previous studies have shown conflicting results." | 2.72 | Can administration of metoclopramide reduce artefacts related to abdominal activity in myocardial perfusion SPECT? ( Brogsitter, C; Burchert, W; GrĂ¼ning, T; Jones, IW; Khonsari, M; Nevin, SM, 2006) |
"Metoclopramide was helpful to reduce the gastric transit time of patients referred for capsule endoscopy." | 1.36 | [Evaluation of capsule endoscopy on the diagnosis of gastrointestinal diseases]. ( Gu, F; Li, J; Lin, SR; Song, ZQ; Yao, W; Zhou, LY, 2010) |
"A simple, reliable and selective square wave anodic stripping (SWAS) voltammetric method at carbon paste electrode (CPE) of metoclopramide hydrochloride (MCP) in pharmaceutical dosage forms (tablet) and in biological fluids (spiked and real urine samples) has been developed and evaluated." | 1.33 | Square wave anodic stripping voltammetric determination of metoclopramide in tablet and urine at carbon paste electrode. ( El-Sayed, AY; Farghaly, OA; Naggar, AH; Taher, MA, 2005) |
"Acetyl acetone is introduced as a new coupling agent for the spectrophotometric determination of some chemotherapeutic agents, such as metoclopramide, dapsone, p-aminobenzoic acid, and cisapride in both pure and dosage forms." | 1.31 | Spectrophotometric determination of some chemotherapeutic agents using acetyl acetone. ( Manju, B; Revanasiddappa, HD, 2002) |
Timeframe | Studies, this research(%) | All Research% |
---|---|---|
pre-1990 | 0 (0.00) | 18.7374 |
1990's | 7 (38.89) | 18.2507 |
2000's | 7 (38.89) | 29.6817 |
2010's | 4 (22.22) | 24.3611 |
2020's | 0 (0.00) | 2.80 |
Authors | Studies |
---|---|
Jacob, VY | 1 |
Stallmach, A | 1 |
Felber, J | 1 |
Hoshino, T | 1 |
Oikawa, T | 1 |
Endo, M | 1 |
Hanawa, T | 1 |
Song, ZQ | 1 |
Gu, F | 1 |
Yao, W | 1 |
Li, J | 1 |
Zhou, LY | 1 |
Lin, SR | 1 |
Ragab, MA | 1 |
Hamamoto, K | 1 |
Mizuno, Y | 1 |
Kato, M | 1 |
Yamagishi, N | 1 |
Furuhama, K | 1 |
Wold, PB | 1 |
Fletcher, JG | 1 |
Johnson, CD | 1 |
Sandborn, WJ | 1 |
Hansen, WF | 1 |
McAndrew, S | 1 |
Harris, K | 1 |
Zimmerman, MB | 1 |
Farghaly, OA | 1 |
Taher, MA | 1 |
Naggar, AH | 1 |
El-Sayed, AY | 1 |
GrĂ¼ning, T | 1 |
Brogsitter, C | 1 |
Khonsari, M | 1 |
Jones, IW | 1 |
Nevin, SM | 1 |
Burchert, W | 1 |
Hun, X | 1 |
Zhang, Z | 1 |
Rubenstein, EB | 1 |
Elting, LS | 1 |
Chaudhuri, L | 1 |
Ganguly, DK | 1 |
Frighetto, L | 1 |
Loewen, PS | 1 |
Dolman, J | 1 |
Marra, CA | 1 |
Yokoyama, H | 1 |
Tsuji, Y | 1 |
Revanasiddappa, HD | 1 |
Manju, B | 1 |
Kuo, BS | 3 |
Poole, JC | 2 |
Hwang, KK | 3 |
Mandagere, AK | 1 |
Osborne, DR | 1 |
Vaughn, V | 1 |
Thompson, TN | 1 |
Chang, J | 1 |
Battor, JL | 1 |
Geary, JI | 1 |
Mandagere, A | 1 |
Trial | Phase | Enrollment | Study Type | Start Date | Status | ||
---|---|---|---|---|---|---|---|
Metoclopramide to Improve Lactogenesis II in Diabetic Women: a Randomized Controlled Trial[NCT00477776] | Phase 3 | 160 participants (Anticipated) | Interventional | 2006-04-30 | Completed | ||
[information is prepared from clinicaltrials.gov, extracted Sep-2024] |
4 trials available for metoclopramide and Sensitivity and Specificity
Article | Year |
---|---|
[Controlled evaluation of a high-resolution three-dimensional magnetic detector system (3D-MAGMA) as a proof of concept - examination of healthy volunteers before and after application of Metoclopramide (MCP)].
Topics: Adult; Antiemetics; Equipment Design; Equipment Failure Analysis; Feasibility Studies; Female; Fiduc | 2016 |
Metoclopramide effect on breastfeeding the preterm infant: a randomized trial.
Topics: Adult; Breast Feeding; Dose-Response Relationship, Drug; Double-Blind Method; Drug Administration Sc | 2005 |
Can administration of metoclopramide reduce artefacts related to abdominal activity in myocardial perfusion SPECT?
Topics: Abdomen; Adenosine; Administration, Oral; Aged; Antiemetics; Artifacts; Exercise Test; Female; Human | 2006 |
[Noninvasive screening for pheochromocytoma in patients with an incidentally discovered adrenal mass: usefulness of provocative test with metoclopramide and 131I-metaiodobenzylguanidine scintigraphy].
Topics: 3-Iodobenzylguanidine; Adenoma; Adrenal Gland Neoplasms; Adult; Biomarkers; Catecholamines; Diagnosi | 1999 |
14 other studies available for metoclopramide and Sensitivity and Specificity
Article | Year |
---|---|
The utility of noninvasive (13)C-acetate breath test using a new solid test meal to measure gastric emptying in mice.
Topics: Acetic Acid; Animal Feed; Animals; Atropine; Breath Tests; Carbon Dioxide; Carbon Isotopes; Gastric | 2008 |
[Evaluation of capsule endoscopy on the diagnosis of gastrointestinal diseases].
Topics: Adolescent; Adult; Aged; Aged, 80 and over; Capsule Endoscopy; Evaluation Studies as Topic; Female; | 2010 |
Effect of metoclopramide on the excretion rate of paracetamol using HPLC-DAD.
Topics: Acetaminophen; Chromatography, High Pressure Liquid; Drug Interactions; Drug Stability; Humans; Line | 2013 |
Simple and sensitive method for measurement of metoclopramide in cattle plasma by LC-MS/MS using a multimode chromatography.
Topics: Animals; Cattle; Chromatography, Liquid; Dopamine Antagonists; Limit of Detection; Metoclopramide; R | 2013 |
Assessment of small bowel Crohn disease: noninvasive peroral CT enterography compared with other imaging methods and endoscopy--feasibility study.
Topics: Administration, Oral; Adult; Barium Sulfate; Contrast Media; Crohn Disease; Endoscopy, Gastrointesti | 2003 |
Square wave anodic stripping voltammetric determination of metoclopramide in tablet and urine at carbon paste electrode.
Topics: Antiemetics; Artifacts; Buffers; Carbon; Electrochemistry; Electrodes; Electrolytes; Humans; Hydroge | 2005 |
Electrogenerated chemiluminescence sensor for metoclopramide determination based on Ru(bpy)3 2+-doped silica nanoparticles dispersed in Nafion on glassy carbon electrode.
Topics: Carbon; Dopamine Antagonists; Electrochemistry; Electrodes; Fluorocarbon Polymers; Glass; Humans; Lu | 2008 |
Re-examination of clinical aspects of pharmacoeconomic analysis.
Topics: Antineoplastic Agents; Economics, Pharmaceutical; Humans; Metoclopramide; Ondansetron; Pharmacology, | 1994 |
Involvement of gamma-aminobutyric acid in the stimulatory effect of metoclopramide on gastrointestinal motility.
Topics: Aminobutyrates; Animals; Arecoline; Bicuculline; Drug Interactions; Ethylenediamines; gamma-Aminobut | 1994 |
Cost-effectiveness of prophylactic dolasetron or droperidol vs rescue therapy in the prevention of PONV in ambulatory gynecologic surgery.
Topics: Ambulatory Surgical Procedures; Antiemetics; Canada; Cost-Benefit Analysis; Decision Support Techniq | 1999 |
Spectrophotometric determination of some chemotherapeutic agents using acetyl acetone.
Topics: 4-Aminobenzoic Acid; Cisapride; Dapsone; Excipients; Hydrogen-Ion Concentration; Indicators and Reag | 2002 |
Validation of a column-switching high-performance liquid chromatographic (HPLC) method for determination of ML-1035 and its five metabolites in plasma.
Topics: Automation; Benzamides; Calibration; Chromatography, High Pressure Liquid; Metoclopramide; Reproduci | 1992 |
Determination of ML-1035 enantiomers in plasma by chiral high-performance liquid chromatography.
Topics: Animals; Chromatography, High Pressure Liquid; Dogs; Metoclopramide; Reproducibility of Results; Sen | 1991 |
Column-switching liquid chromatographic determination of ML-1035 sulphoxide and its sulphone and sulphide metabolites in rat urine.
Topics: Animals; Chromatography, Liquid; Drug Stability; Metoclopramide; Molecular Structure; Rats; Reproduc | 1991 |