kaolinite has been researched along with Heart-Defects--Congenital* in 3 studies
3 other study(ies) available for kaolinite and Heart-Defects--Congenital
Article | Year |
---|---|
Experience Using Kaolin-Impregnated Sponge to Minimize Perioperative Bleeding in Norwood Operation.
A kaolin-impregnated hemostatic sponge (QuikClot) is reported to reduce intraoperative blood loss in trauma and noncardiac surgery. The purpose of this study was to assess if this sponge was effective for hemostasis during Norwood operation.. We conducted a retrospective review of patients undergoing Norwood operation in infancy between 2011 and 2016 at our institution.. Of 31 identified Norwood operations, a kaolin-impregnated sponge was used intraoperatively in 15 (48%) patients. The preoperative profiles and cardiopulmonary bypass status were similar between the operations with or without kaolin-impregnated sponge. The comparison on each operative outcome between operations with or without kaolin-impregnated sponge showed that the intraoperative platelets, cryoprecipitate, and factor VII dosage were significantly less in the operations with kaolin-impregnated sponge (55 mL, 10 mL, 0 µg/kg vs 72 mL, 15 mL, 45 µg/kg; P = .03, .021, .019), as well as the incidence of perioperative bleeding complications (second cardiopulmonary bypass for hemostasis or postoperative mediastinal exploration, 0% vs 31%, P = .043). A logistic regression model showed that the nonuse of kaolin-impregnated sponge and longer aortic cross clamp time were associated with perioperative bleeding complication in univariable model ( P = .02 and .005).. Use of kaolin-impregnated hemostatic sponge was associated with reduced blood product use and perioperative bleeding complications in Norwood operation at a single institution. Topics: Aged; Blood Loss, Surgical; Female; Follow-Up Studies; Heart Defects, Congenital; Hemostatic Techniques; Humans; Infant; Infant, Newborn; Kaolin; Male; Middle Aged; Norwood Procedures; Retrospective Studies; Surgical Sponges; Treatment Outcome | 2017 |
Kaolin-activated thromboelastography and standard coagulation assays in cyanotic and acyanotic infants undergoing complex cardiac surgery: a prospective cohort study.
Several studies report the use of thromboelatography (TEG) to monitor coagulation in pediatric cardiac surgery. The aim of this study was to compare baseline and intraoperative TEG, TEG-functional fibrinogen, and standard coagulation assays in children with cyanotic and acyanotic congenital heart disease (CHD) undergoing cardiac surgery.. This is a prospective observational study of 63 children aged <24 months undergoing cardiac surgery with cardiopulmonary bypass (CPB). Exclusion criteria included preoperative anticoagulant therapy and hepatic failure. We collected blood at anesthesia induction (T1), at lowest temperature after CPB start (T2), and after heparin neutralization (T3). Coagulation was evaluated by TEG (reaction time [R]), k, alpha-angle, maximum amplitude (MA), MA-fibrinogen (MA-fib), and by standard coagulation assays (prothrombin time, activated partial thromboplastin time, fibrinogen level, platelet [PLT] count).. Sixty-three patients were enrolled (38 cyanotic and 25 acyanotic). Median age was 4 [IQR 2-6] months and median weight was 5 [IQR 3.7-6.5] kg. Most common surgeries were: ventricular septal defect repair (n = 13), Fallot correction (n = 11), and arterial switch operation (n = 10). Cyanotic and acyanotic children were well matched: R, k, MA, and MA-fib at T1, T2, and T3 were not significantly different between cyanotic and acyanotic children. At T2, significant correlations were showed between MA and PLT count (r = 0.4; P = 0.0008) and k and plasma fibrinogen level (r = -0.54; P < 0.0001). At T3, significant correlations were showed between MA and PLT count (r = 0.5; P < 0.0001), G and PLT count (r = 0.6; P < 0.0001), and MA-fib and plasma fibrinogen level (r = 0.5; P = 0.002).. According to our findings, cyanosis does not affect TEG parameters in children with CHD. PLT count and plasma fibrinogen significantly correlated (are significantly associated) with MA and MA-fib respectively, suggesting that use of TEG after protamine administration may be prompted for improved hemostatic monitoring in the perioperative phase. Topics: Blood Coagulation; Blood Coagulation Tests; Cardiac Surgical Procedures; Cohort Studies; Cyanosis; Female; Fibrinogen; Heart Defects, Congenital; Humans; Infant; Intraoperative Care; Kaolin; Male; Platelet Count; Prospective Studies; Thrombelastography | 2017 |
[THE COMPARATIVE CHARACTERISTIC OF KAOLIN-ACTIVATED THROMBOELASTOGRAPHY IN HEALTHY NEWBORNS AND NEWBORNS WITH HEART AILMENTS].
The study was carried out to diferentiate reference values for kaolin-activated thromboelastography in newborns with congenital heart disease. The study included two groups ofpatients. The first one consisted of 62 newborns with congenital heart disease and the second one consisted of 35 healthy newborns. The results of kaolin-activated thromboelastography implemented in groups are evaluated as condition of normal coagulation. The valuable diferences of homeostasis system in healthy newborns and newborns with congenital heart disease (without severe concomitant pathology) are not established. They have similar indicators of kaolin-activated thromboelastography. The derived results can be applied as standards in full-term newborns with congenital heart disease. Topics: Blood Coagulation; Case-Control Studies; Female; Heart Defects, Congenital; Humans; Infant, Newborn; Kaolin; Male; Partial Thromboplastin Time; Prothrombin Time; Reference Values; Thrombelastography; Thrombin Time; Whole Blood Coagulation Time | 2016 |