jwh-073 and Marijuana-Abuse

jwh-073 has been researched along with Marijuana-Abuse* in 2 studies

Other Studies

2 other study(ies) available for jwh-073 and Marijuana-Abuse

ArticleYear
JWH-018 and JWH-073: Δ⁹-tetrahydrocannabinol-like discriminative stimulus effects in monkeys.
    The Journal of pharmacology and experimental therapeutics, 2012, Volume: 340, Issue:1

    Products containing naphthalen-1-yl-(1-pentylindol-3-yl) methanone (JWH-018) and naphthalen-1-yl-(1-butylindol-3-yl) methanone (JWH-073) are emerging drugs of abuse. Here, the behavioral effects of JWH-018 and JWH-073 were examined in one behavioral assay selective for cannabinoid agonism, rhesus monkeys (n = 4) discriminating Δ⁹-tetrahydrocannabinol (Δ⁹-THC; 0.1 mg/kg i.v.), and another assay sensitive to cannabinoid withdrawal, i.e., monkeys (n = 3) discriminating the cannabinoid antagonist rimonabant (1 mg/kg i.v.) during chronic Δ⁹-THC (1 mg/kg s.c. 12 h) treatment. Δ⁹-THC, JWH-018, and JWH-073 increased drug-lever responding in monkeys discriminating Δ⁹-THC; the ED₅₀ values were 0.044, 0.013, and 0.058 mg/kg, respectively and the duration of action was 4, 2, and 1 h, respectively. Rimonabant (0.32-3.2 mg/kg) produced surmountable antagonism of Δ⁹-THC, JWH-018, and JWH-073. Schild analyses and single-dose apparent affinity estimates yielded apparent pA₂/pK(B) values of 6.65, 6.68, and 6.79 in the presence of Δ⁹-THC, JWH-018, and JWH-073, respectively. In Δ⁹-THC-treated monkeys discriminating rimonabant, the training drug increased responding on the rimonabant lever; the ED₅₀ value of rimonabant was 0.20 mg/kg. Δ⁹-THC (1-10 mg/kg), JWH-018 (0.32-3.2 mg/kg), and JWH-073 (3.2-32 mg/kg) dose-dependently attenuated the rimonabant-discriminative stimulus (i.e., withdrawal). These results suggest that Δ⁹-THC, JWH-018, and JWH-073 act through the same receptors to produce Δ⁹-THC-like subjective effects and attenuate Δ⁹-THC withdrawal. The relatively short duration of action of JWH-018 and JWH-073 might lead to more frequent use, which could strengthen habitual use by increasing the frequency of stimulus-outcome pairings. This coupled with the possible greater efficacy of JWH-018 at cannabinoid 1 receptors could be associated with greater dependence liability than Δ⁹-THC.

    Topics: Animals; Behavior, Animal; Conditioning, Operant; Data Interpretation, Statistical; Discrimination Learning; Discrimination, Psychological; Dose-Response Relationship, Drug; Dronabinol; Female; Hallucinogens; Illicit Drugs; Indoles; Macaca mulatta; Male; Marijuana Abuse; Naphthalenes; Piperidines; Pyrazoles; Receptor, Cannabinoid, CB1; Rimonabant; Substance Withdrawal Syndrome

2012
Detection of JWH-018 and JWH-073 by UPLC-MS-MS in postmortem whole blood casework.
    Journal of analytical toxicology, 2012, Volume: 36, Issue:3

    Synthetic cannabinoids have been detected in various herbal blends sold legally in convenience stores, smoke shops, and on the Internet. Many of these compounds have extreme forensic significance. We developed and validated a rapid ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of trace concentrations of two of these compounds, JWH-018 and JWH-073, in human blood. Samples underwent liquid-liquid extraction at pH 10.2 into ethyl ether. Tandem mass spectrometry was performed in positive electrospray ionization mode with multiple reaction monitoring using two transitions and one calculated ion transition ratio for each analyte. Deuterated analogs were used as internal standards. Total run time was 2.6 min. The linear dynamic range was 0.05-50 ng/mL with a limit of detection of 0.01 ng/mL for each analyte. Intra-run imprecision (at two different concentration levels, 2 and 8 ng/mL) was 3.9-10.3% for JWH-018 and 3.5-6.2% for JWH-073. Inter-run imprecision was 6.5-7.2% for JWH-018 and 4.8-5.5% for JWH-073. Intra-run accuracy was 95.9-112.7% for JWH-018 and 92.6-104.7% for JWH-073. Inter-run accuracy was 99.1-107.0% for JWH-018 and 97.7-102.0% for JWH-073. Carryover, exogenous drug interferences, ion suppression and matrix selectivity were also assessed. The method has been applied to postmortem forensic casework received by the laboratory and has proven to be robust and reliable. Concentrations of authentic samples have ranged from 0.1-199 ng/mL for JWH-018 and 0.1-68.3 ng/mL for JWH-073.

    Topics: Adult; Chromatography, High Pressure Liquid; Forensic Toxicology; Humans; Indoles; Male; Marijuana Abuse; Middle Aged; Naphthalenes; Reproducibility of Results; Spectrometry, Mass, Electrospray Ionization; Substance Abuse Detection; Tandem Mass Spectrometry

2012