Page last updated: 2024-10-29

iopromide and Arteriosclerosis, Coronary

iopromide has been researched along with Arteriosclerosis, Coronary in 60 studies

iopromide: structure given in first source
iopromide : A dicarboxylic acid diamide that consists of N-methylisophthalamide bearing three iodo substituents at positions 2, 4 and 6, a methoxyacetyl substituent at position 5 and two 2,3-dihydroxypropyl groups attached to the amide nitrogens. A water soluble x-ray contrast agent for intravascular administration.

Research Excerpts

ExcerptRelevanceReference
"With current CT technology, iobitridol 350 mg iodine/ml is not inferior to contrast media with higher iodine concentrations in terms of image quality for coronary stenosis assessment."5.24Comparative assessment of image quality for coronary CT angiography with iobitridol and two contrast agents with higher iodine concentrations: iopromide and iomeprol. A multicentre randomized double-blind trial. ( Achenbach, S; Andreu, J; Becker, HC; Benea, G; Cabeza, B; Cademartiri, F; Caudron, J; Jacquier, A; Knobloch, G; Laurent, F; Leschka, S; Paul, JF; Qanadli, SD; Rengo, M; Revel, D; Schlosser, T; Souto, M; Vignaux, O, 2017)
" In 562 evaluable patients (of 592 recruited), the contrast volume, presence of diabetes mellitus, mean baseline SCr and estimated glomerular filtration rate (eGFR) were comparable between the iopromide- and iodixanol-treated groups."5.16Renal tolerability of iopromide and iodixanol in 562 renally impaired patients undergoing cardiac catheterisation: the DIRECT study. ( Chen, Y; Fu, G; Gao, C; Gao, W; He, B; He, Q; Hu, S; Liu, H; Liu, S; Liu, Y; Qi, X; Qiu, C; Su, X; Wang, J; Wang, L; Wang, M; Yang, P; Zhao, R; Zheng, X; Zheng, Y; Zhou, S, 2012)
"Forty consecutive patients (29 male, 11 female; mean age, 61+/-11 years) with suspected coronary artery disease were randomized to 2 groups to receive 100 mL of either iopromide 370 (group 1: Ultravist 370, 370 mg iodine/mL; Schering AG, Berlin, Germany) or iomeprol 400 (group 2: Iomeron 400, 400 mg iodine/mL; Bracco Imaging SpA, Milan, Italy)."5.12High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography: iopromide 370 versus iomeprol 400. ( Cademartiri, F; de Feyter, PJ; de Monye, C; Krestin, GP; Lagalla, R; Midiri, M; Mollet, NR; Pugliese, F; Runza, G; van der Lugt, A, 2006)
" 16 patients (12 male, age, 69 ± 8 years) with known or suspected coronary artery disease underwent invasive coronary angiography with fractional flow reserve (FFR) measurements using a pressure wire as well as a time-resolved CTP protocol under adenosine stress, performed on a dual-Source CT scanner over a period of 30 s."3.79Optimal timing for first-pass stress CT myocardial perfusion imaging. ( Bamberg, F; Becker, A; Becker, HC; Bischoff, B; Marcus, R; Nikolaou, K; Reiser, M; Schwarz, F, 2013)
"Fifty consecutive patients with coronary artery disease (CAD) and normal left ventricular ejection fraction were studied by coronary arteriography for a stable or unstable coronary syndrome by using iopromide."3.72Left ventricular diastolic impairment during coronary arteriography with a non-ionic contrast medium. ( Baglini, R; Capuano, C; Danzi, GB; Rosella, MG; Sardeo, C; Sesana, M, 2004)
"The IVUS studies revealed that atherosclerotic plaque burden, fibrous tissue, dense calcific tissue, and necrotic core ratios were significantly higher in the coronary segments with CL compared with adjacent normal segments."1.42Contrast layering: late clearance of contrast dye--a novel angiographic phenomenon of early atherosclerosis. ( Caglar, FN; Caglar, IM; Ciftci, S; Dasli, T; Demir, B; Gedikbasi, A; Karakaya, O; Ugurlucan, M; Ungan, I; Vural, A, 2015)
"Mean iodine loads were significantly reduced in the study group ((18."1.42[Application feasibility of low tube voltage and lower iodine concentration contrast medium as well as iterative reconstruction in coronary computed tomography angiography]. ( Han, L; Hou, Z; Jiang, S; Li, N; Lyu, B; Yin, W, 2015)
"In histology, percentage area of stenosis (BMS+PCB=29."1.39Stent healing response following delivery of paclitaxel via durable polymeric matrix versus iopromide-based balloon coating in the familial hypercholesterolaemic swine model of coronary injury. ( Afari, M; Buszman, PP; Cheng, Y; Conditt, GB; Granada, JF; Kaluza, GL; McGregor, JC; Milewski, K; Stenoien, M; Tellez, A, 2013)
"We report the case of a newborn with pulmonary atresia with intact ventricular septum and right ventricle-dependent coronary circulation."1.37Critical stenosis of a right ventricle to coronary artery fistula seen at dual-source CT in a newborn with pulmonary atresia and intact ventricular septum. ( Houyel, L; Loget, P; Paul, JF; Piot, JD; Séguéla, PE, 2011)
" So HR, gender, TCD and weight can be used to adjust flow rate and dosage of contrast media before administration of contrast media during coronary CT angiography."1.37Factors influencing delay time and coronary arterial density during coronary angiography with DSCT. ( Dogra, V; Tang, J; Tang, L; Wang, D; Xu, H; Xu, Y; Yu, T; Zhu, X, 2011)
"Homozygous familial hypercholesterolemia (HoFH) is a rare disorder characterized by the early onset of atherosclerosis and usually occurs at the ostia of coronary arteries."1.36Evaluation of coronary flow velocity reserve in homozygous familial hypercholesterolemia by transthoracic Doppler echocardiography and dual-source computed tomography. ( Li, R; Li, Z; Lin, J; Ren, H; Wang, L; Wang, Z; Yang, Y; Yu, W; Zhang, X; Zhang, Z, 2010)
"Ten patients with subclavian artery stenosis and upper limb ischemia underwent subclavian artery angioplasty and stenting and bypass surgery using LIMA."1.33Vascular profile of patients with multivessel coronary artery disease. ( Rigatelli, G, 2006)

Research

Studies (60)

TimeframeStudies, this research(%)All Research%
pre-19900 (0.00)18.7374
1990's0 (0.00)18.2507
2000's17 (28.33)29.6817
2010's43 (71.67)24.3611
2020's0 (0.00)2.80

Authors

AuthorsStudies
Yang, SF1
Chou, RH1
Li, SY1
Huang, SS1
Huang, PH1
Schröder, J1
Vogt, F1
Burgmaier, M1
Reith, S1
Almalla, M1
Rengo, M2
Dharampal, A1
Lubbers, M1
Kock, M1
Wildberger, JE2
Das, M2
Niezen, A1
van Tilborg, F1
Kofflard, M1
Laghi, A1
Krestin, G1
Nieman, K3
Pan, Y1
Huang, Q1
Zhu, Y3
Zou, X1
Chu, H1
Du, X2
Li, A1
Bu, S1
Oberoi, S2
Schoepf, UJ7
Meyer, M1
Henzler, T2
Rowe, GW2
Costello, P2
Nance, JW4
Mittal, TK1
Panicker, MG1
Mitchell, AG1
Banner, NR1
Sajeev, CG1
Mohanan, S1
Gopalakrishnapillai, A1
Muneer, K1
Buszman, PP1
Tellez, A1
Afari, M1
Cheng, Y1
Conditt, GB1
McGregor, JC1
Milewski, K1
Stenoien, M1
Kaluza, GL1
Granada, JF1
Zhu, X3
Xu, H3
Wan, Y1
Choo, KS2
Yang, G1
Tang, L3
Xu, Y3
Meinel, FG2
De Cecco, CN3
Silverman, JR3
Flowers, BA1
Caglar, IM1
Demir, B1
Caglar, FN1
Vural, A1
Ugurlucan, M1
Ciftci, S1
Ungan, I1
Gedikbasi, A1
Dasli, T1
Karakaya, O1
Secchi, F1
Spearman, JV2
Ebersberger, U2
Sardanelli, F1
Ko, SM1
Park, JH1
Hwang, HK1
Song, MG1
Zhang, LJ1
Qi, L1
Wang, J3
Tang, CX1
Zhou, CS1
Ji, XM1
Lu, GM1
Mariani, J1
Guedes, C1
Soares, P1
Zalc, S1
Campos, CM1
Lopes, AC1
Spadaro, AG1
Perin, MA1
Filho, AE1
Takimura, CK1
Ribeiro, E1
Kalil-Filho, R1
Edelman, ER1
Serruys, PW2
Lemos, PA1
Kim, JJ1
Hwang, BH1
Choi, IJ1
Choo, EH1
Lim, S1
Kim, JK1
Koh, YS1
Kim, DB1
Jang, SW1
Cho, EJ1
Lee, JM1
Kim, PJ1
Cho, JH1
Jung, JI1
Seung, KB1
Min, JK1
Chang, K1
Han, L1
Yin, W1
Lyu, B1
Li, N1
Hou, Z1
Jiang, S1
Pan, YN1
Li, AJ1
Chen, XM1
Ren, DW1
Huang, QL1
Achenbach, S3
Paul, JF3
Laurent, F1
Becker, HC2
Caudron, J1
Leschka, S1
Vignaux, O1
Knobloch, G1
Benea, G1
Schlosser, T1
Andreu, J1
Cabeza, B1
Jacquier, A1
Souto, M1
Revel, D1
Qanadli, SD1
Cademartiri, F2
Nie, B1
Cheng, WJ1
Li, YF1
Cao, Z1
Yang, Q1
Zhao, YX1
Guo, YH1
Zhou, YJ1
Seifarth, H1
Puesken, M1
Kalafut, JF1
Wienbeck, S1
Wessling, J1
Maintz, D1
Heindel, W1
Juergens, KU1
Stolzmann, P2
Alkadhi, H2
Scheffel, H2
Hennemuth, A1
Kuehnel, C1
Baumueller, S1
Kozerke, S2
Falk, V1
Marincek, B1
Donati, OF2
Rutten, A1
Meijs, MF1
de Vos, AM1
Seidensticker, PR1
Prokop, M1
Bamberg, F5
Klotz, E1
Flohr, T1
Becker, A2
Becker, CR1
Schmidt, B1
Wintersperger, BJ1
Reiser, MF1
Nikolaou, K3
Yang, Y1
Zhang, X1
Li, R1
Ren, H1
Wang, Z1
Li, Z1
Lin, J1
Wang, L2
Yu, W1
Zhang, Z1
Kim, EY1
Yeh, DW1
Choe, YH1
Lee, WJ1
Lim, HK1
Atar, E1
Kornowski, R1
Bachar, GN1
Desbiolles, L1
Hoffmann, U1
Sandgaard, NC1
Diederichsen, AC1
Petersen, H1
Høilund-Carlsen, PF1
Mickley, H1
Séguéla, PE1
Houyel, L1
Loget, P1
Piot, JD1
Cao, L1
Li, P1
Sun, Z1
Zhang, Q1
Li, K1
Yu, T1
Tang, J1
Dogra, V1
Wang, D2
Jeong, DW1
Baik, SK1
Kim, YW1
Jeon, UB1
Kim, JS1
Lim, SJ1
Laspas, F1
Tsantioti, D1
Roussakis, A1
Kritikos, N1
Efthimiadou, R1
Kehagias, D1
Andreou, J1
Kang, DK1
Barraza, JM2
Abro, JA1
Bastarrika, G1
Headden, GF2
Thilo, C1
Chen, W1
Li, M1
Papadopoulou, SL1
Brugaletta, S1
Garcia-Garcia, HM1
Rossi, A1
Girasis, C1
Dharampal, AS1
Neefjes, LA1
Ligthart, J1
Krestin, GP2
de Feyter, PJ2
Bischoff, B1
Marcus, R1
Schwarz, F1
Reiser, M1
Reinartz, SD1
Diefenbach, BS1
Allmendinger, T1
Kuhl, CK1
Mahnken, AH3
Schlett, CL1
Leisy, HB1
Rutsch, W1
Scheller, B1
Borges, AC1
Bräutigam, M1
Clever, Y1
Cremers, B1
Dietz, U1
Richter, W1
Speck, U1
Amato, A1
Rohnean, A1
Hou, ZH1
Lu, B1
Gao, Y2
Cao, HL1
Yu, FF1
Jing, N1
Chen, X1
Cong, XF1
Roy, SK1
Budoff, MJ2
Eilot, D1
Goldenberg, R1
Lev, A1
Spears, JR1
Gallagher, NY1
Halligan, WT1
Blanke, P1
Makowski, MR1
Krazinski, AW1
Leber, AW1
Hoffmann, E1
Chen, Y1
Hu, S1
Liu, Y1
Zhao, R1
Fu, G1
He, Q1
Su, X1
Zheng, Y1
Qi, X1
Liu, H1
Gao, W1
Wang, M1
Liu, S1
Zheng, X1
He, B1
Yang, P1
Zhou, S1
Gao, C1
Qiu, C1
Baglini, R2
Sesana, M1
Capuano, C1
Rosella, MG1
Sardeo, C1
Danzi, GB1
Mühlenbruch, G2
Koos, R1
Flohr, TG1
Niethammer, M1
Weiss, C1
Günther, RW2
Rigatelli, G2
Sandstede, JJ1
Stoffels, J1
Wendel, F1
Ritter, C1
Beer, M1
Hahn, D1
Ferencik, M1
de Monye, C1
Pugliese, F1
Mollet, NR1
Runza, G1
van der Lugt, A1
Midiri, M1
Lagalla, R1
Paijitprapaporn, P1
Jongjirasiri, S1
Tangpagasit, L1
Laothamatas, J1
Reungratanaamporn, O1
Mahanonda, N1
Gul, KM1
Mao, SS1
Oudiz, RJ1
Rasouli, ML1
Gopal, A1
Halliburton, SS1
Schoenhagen, P1
Nair, A1
Stillman, A1
Lieber, M1
Murat Tuzcu, E1
Geoffrey Vince, D1
White, RD1
Erdoğan, D1
Güllü, H1
Calişkan, M1
Ulus, T1
Müderrisoğlu, H1
Büther, F1
Stegger, L1
Dawood, M1
Range, F1
Schäfers, M1
Fischbach, R1
Wichter, T1
Schober, O1
Schäfers, KP1
Rubinshtein, R1
Halon, DA1
Gaspar, T1
Jaffe, R1
Goldstein, J1
Karkabi, B1
Flugelman, MY1
Kogan, A1
Shapira, R1
Peled, N1
Lewis, BS1
Schmid, M1
Ropers, D1
Komatsu, S1
Ropers, U1
Daniel, WG1
Pflederer, T1
Plumhans, C1
Rapaee, A1
Sim, KH1
Seyfarth, T1
Limbruno, U1
Petronio, AS1
Mariani, M1
De Caterina, R1

Clinical Trials (6)

Trial Overview

TrialPhaseEnrollmentStudy TypeStart DateStatus
Renal Insufficiency Following Contrast Media Administration Trial IV: Contrast Media Volume Control for Limiting Contrast-Induced Acute Kidney in Acute Coronary Syndrome.[NCT04714736]522 participants (Anticipated)Interventional2020-02-10Recruiting
Minimizing cOntrast utiliZAtion With IVUS Guidance in coRonary angioplasTy: The MOZART Study[NCT01947335]Phase 483 participants (Actual)Interventional2012-11-30Completed
IVUS Based Ultra-low Volume Contrast Media PCI to Reduce Contrast Induced Nephrology in Patient With Chronic Kidney disease-a Multi-center, Open Label, Randomized Trial (IVUS-CKD)[NCT05913362]320 participants (Anticipated)Interventional2023-10-01Not yet recruiting
The Safety, Feasibility and Accuracy of Dynamic Computed Tomography Myocardial Perfusion Imaging for Detection of Coronary Artery Disease[NCT03324308]10 participants (Actual)Interventional2018-03-30Active, not recruiting
Chinese People's Liberation Army General Hospital[NCT02718521]400 participants (Anticipated)Interventional2016-03-31Active, not recruiting
A Randomized, Double-blinded Comparison of Iopromide and Iodixanol in Renally Impaired Patients Undergoing Cardiac Catheterization[NCT00926562]Phase 4592 participants (Actual)Interventional2009-02-28Completed
[information is prepared from clinicaltrials.gov, extracted Sep-2024]

Trial Outcomes

Incidence of Contrast-induced Nephropathy

Increase >= 0.5 mg/dl in basal serum creatinine (NCT01947335)
Timeframe: 7 days

Interventionpercentage of participants (Number)
Angiography-guided PCI19
IVUS-guided PCI7.3

Total Volume of Iodine Contrast Used During Procedure

Total volume of iodine contrast administered during the index procedure. (NCT01947335)
Timeframe: Day 1

Interventionml (Median)
Angiography-guided PCI64.5
IVUS-guided PCI20.0

Major Adverse Cardiac Events

Composite of death, myocardial infarction or repeat revascularization (NCT01947335)
Timeframe: 30 days and 6 months

,
Interventionparticipants (Number)
30 days6-months
Angiography-guided PCI22
IVUS-guided PCI25

Reviews

1 review available for iopromide and Arteriosclerosis, Coronary

ArticleYear
Assessment of coronary vasomotor function: old and new tools.
    Italian heart journal : official journal of the Italian Federation of Cardiology, 2000, Volume: 1, Issue:4

    Topics: Blood Flow Velocity; Contrast Media; Coronary Angiography; Coronary Artery Disease; Coronary Vessels

2000

Trials

16 trials available for iopromide and Arteriosclerosis, Coronary

ArticleYear
Impact of iodine concentration and iodine delivery rate on contrast enhancement in coronary CT angiography: a randomized multicenter trial (CT-CON).
    European radiology, 2019, Volume: 29, Issue:11

    Topics: Computed Tomography Angiography; Contrast Media; Coronary Angiography; Coronary Artery Disease; Coro

2019
An individualized contrast material injection protocol with respect to patient-related factors for dual-source CT coronary angiography.
    Clinical radiology, 2014, Volume: 69, Issue:2

    Topics: Adult; Aged; Aged, 80 and over; Body Mass Index; Body Size; Body Weight; Contrast Media; Coronary An

2014
Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial.
    JACC. Cardiovascular interventions, 2014, Volume: 7, Issue:11

    Topics: Acute Kidney Injury; Aged; Biomarkers; Contrast Media; Coronary Angiography; Coronary Artery Disease

2014
Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial.
    JACC. Cardiovascular interventions, 2014, Volume: 7, Issue:11

    Topics: Acute Kidney Injury; Aged; Biomarkers; Contrast Media; Coronary Angiography; Coronary Artery Disease

2014
Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial.
    JACC. Cardiovascular interventions, 2014, Volume: 7, Issue:11

    Topics: Acute Kidney Injury; Aged; Biomarkers; Contrast Media; Coronary Angiography; Coronary Artery Disease

2014
Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial.
    JACC. Cardiovascular interventions, 2014, Volume: 7, Issue:11

    Topics: Acute Kidney Injury; Aged; Biomarkers; Contrast Media; Coronary Angiography; Coronary Artery Disease

2014
Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial.
    JACC. Cardiovascular interventions, 2014, Volume: 7, Issue:11

    Topics: Acute Kidney Injury; Aged; Biomarkers; Contrast Media; Coronary Angiography; Coronary Artery Disease

2014
Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial.
    JACC. Cardiovascular interventions, 2014, Volume: 7, Issue:11

    Topics: Acute Kidney Injury; Aged; Biomarkers; Contrast Media; Coronary Angiography; Coronary Artery Disease

2014
Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial.
    JACC. Cardiovascular interventions, 2014, Volume: 7, Issue:11

    Topics: Acute Kidney Injury; Aged; Biomarkers; Contrast Media; Coronary Angiography; Coronary Artery Disease

2014
Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial.
    JACC. Cardiovascular interventions, 2014, Volume: 7, Issue:11

    Topics: Acute Kidney Injury; Aged; Biomarkers; Contrast Media; Coronary Angiography; Coronary Artery Disease

2014
Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial.
    JACC. Cardiovascular interventions, 2014, Volume: 7, Issue:11

    Topics: Acute Kidney Injury; Aged; Biomarkers; Contrast Media; Coronary Angiography; Coronary Artery Disease

2014
Coronary Computed Tomographic Angiography at Low Concentration of Contrast Agent and Low Tube Voltage in Patients with Obesity:: A Feasibility Study.
    Academic radiology, 2016, Volume: 23, Issue:4

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Coronary Angiography; Coronary Artery Disease; Feasi

2016
Comparative assessment of image quality for coronary CT angiography with iobitridol and two contrast agents with higher iodine concentrations: iopromide and iomeprol. A multicentre randomized double-blind trial.
    European radiology, 2017, Volume: 27, Issue:2

    Topics: Adult; Aged; Calcinosis; Computed Tomography Angiography; Contrast Media; Coronary Angiography; Coro

2017
A prospective, double-blind, randomized, controlled trial on the efficacy and cardiorenal safety of iodixanol vs. iopromide in patients with chronic kidney disease undergoing coronary angiography with or without percutaneous coronary intervention.
    Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions, 2008, Dec-01, Volume: 72, Issue:7

    Topics: Acute Kidney Injury; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Diseases; Contrast Media;

2008
Introduction of an individually optimized protocol for the injection of contrast medium for coronary CT angiography.
    European radiology, 2009, Volume: 19, Issue:10

    Topics: Contrast Media; Coronary Artery Disease; Female; Humans; Injections, Intra-Arterial; Iohexol; Male;

2009
Biphasic contrast medium injection in cardiac CT: moderate versus high concentration contrast material at identical iodine flux and iodine dose.
    European radiology, 2010, Volume: 20, Issue:8

    Topics: Contrast Media; Coronary Angiography; Coronary Artery Disease; Dose-Response Relationship, Drug; Fem

2010
Image quality and attenuation values of multidetector CT coronary angiography using high iodine-concentration contrast material: a comparison of the use of iopromide 370 and iomeprol 400.
    Acta radiologica (Stockholm, Sweden : 1987), 2010, Volume: 51, Issue:9

    Topics: Adult; Aged; Contrast Media; Coronary Angiography; Coronary Artery Disease; Female; Humans; Iohexol;

2010
Optimization of contrast medium protocol in CT coronary arteriography: constant injection dose rate adapted to body weight.
    Acta radiologica (Stockholm, Sweden : 1987), 2011, Jul-01, Volume: 52, Issue:6

    Topics: Adult; Aged; Aorta, Thoracic; Body Weight; Contrast Media; Coronary Angiography; Coronary Artery Dis

2011
Contrast material injection protocol with the flow rate adjusted to the heart rate for dual source CT coronary angiography.
    The international journal of cardiovascular imaging, 2012, Volume: 28, Issue:6

    Topics: Adult; Aged; Aged, 80 and over; Cardiac Output; Cardiac-Gated Imaging Techniques; Chi-Square Distrib

2012
Intracoronary local paclitaxel delivery by X-ray contrast media for in-stent restenosis: a clinical pilot study to assess safety and tolerability.
    Minerva cardioangiologica, 2012, Volume: 60, Issue:4

    Topics: Aged; Algorithms; Cardiac Catheterization; Cardiovascular Agents; Contrast Media; Coronary Angiograp

2012
Renal tolerability of iopromide and iodixanol in 562 renally impaired patients undergoing cardiac catheterisation: the DIRECT study.
    EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 2012, Nov-22, Volume: 8, Issue:7

    Topics: Aged; Biomarkers; Cardiac Catheterization; China; Contrast Media; Coronary Angiography; Coronary Art

2012
Renal tolerability of iopromide and iodixanol in 562 renally impaired patients undergoing cardiac catheterisation: the DIRECT study.
    EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 2012, Nov-22, Volume: 8, Issue:7

    Topics: Aged; Biomarkers; Cardiac Catheterization; China; Contrast Media; Coronary Angiography; Coronary Art

2012
Renal tolerability of iopromide and iodixanol in 562 renally impaired patients undergoing cardiac catheterisation: the DIRECT study.
    EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 2012, Nov-22, Volume: 8, Issue:7

    Topics: Aged; Biomarkers; Cardiac Catheterization; China; Contrast Media; Coronary Angiography; Coronary Art

2012
Renal tolerability of iopromide and iodixanol in 562 renally impaired patients undergoing cardiac catheterisation: the DIRECT study.
    EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 2012, Nov-22, Volume: 8, Issue:7

    Topics: Aged; Biomarkers; Cardiac Catheterization; China; Contrast Media; Coronary Angiography; Coronary Art

2012
High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography: iopromide 370 versus iomeprol 400.
    Investigative radiology, 2006, Volume: 41, Issue:3

    Topics: Adult; Aged; Contrast Media; Coronary Angiography; Coronary Artery Disease; Female; Humans; Injectio

2006
Noninvasive gadolinium-enhanced three dimensional computed tomography coronary angiography.
    Academic radiology, 2006, Volume: 13, Issue:7

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Coronary Angiography; Coronary Artery Disease; Dose-

2006
Assessment of global right ventricular function on 64-MDCT compared with MRI.
    AJR. American journal of roentgenology, 2008, Volume: 190, Issue:5

    Topics: Contrast Media; Coronary Artery Disease; Electrocardiography; Female; Humans; Image Processing, Comp

2008

Other Studies

43 other studies available for iopromide and Arteriosclerosis, Coronary

ArticleYear
Serum Corin Level Is Associated With Subsequent Decline in Renal Function in Patients With Suspected Coronary Artery Disease.
    Journal of the American Heart Association, 2018, 05-04, Volume: 7, Issue:10

    Topics: Aged; Aged, 80 and over; Biomarkers; Contrast Media; Coronary Angiography; Coronary Artery Disease;

2018
Long-term clinical outcomes after treatment of stent restenosis with two drug-coated balloons.
    Coronary artery disease, 2018, Volume: 29, Issue:8

    Topics: Aged; Aged, 80 and over; Angioplasty, Balloon, Coronary; Butyrates; Cardiac Catheters; Cardiovascula

2018
Diagnosis of coronary artery disease in patients with atrial fibrillation using low tube voltage coronary CT angiography with isotonic low-concentration contrast agent.
    The international journal of cardiovascular imaging, 2019, Volume: 35, Issue:12

    Topics: Adult; Aged; Aged, 80 and over; Atrial Fibrillation; Computed Tomography Angiography; Contrast Media

2019
Progression of arterial stiffness and coronary atherosclerosis: longitudinal evaluation by cardiac CT.
    AJR. American journal of roentgenology, 2013, Volume: 200, Issue:4

    Topics: Cardiac-Gated Imaging Techniques; Contrast Media; Coronary Angiography; Coronary Artery Disease; Dis

2013
Cardiac allograft vasculopathy after heart transplantation: electrocardiographically gated cardiac CT angiography for assessment.
    Radiology, 2013, Volume: 268, Issue:2

    Topics: Adult; Aged; Aged, 80 and over; Cardiac-Gated Imaging Techniques; Chi-Square Distribution; Contrast

2013
A rare complication of coronary angiography: 'iodide mumps'.
    Heart (British Cardiac Society), 2013, Volume: 99, Issue:16

    Topics: Aged; Contrast Media; Coronary Angiography; Coronary Artery Disease; Humans; Iohexol; Male; Sialaden

2013
Stent healing response following delivery of paclitaxel via durable polymeric matrix versus iopromide-based balloon coating in the familial hypercholesterolaemic swine model of coronary injury.
    EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 2013, Aug-22, Volume: 9, Issue:4

    Topics: Angioplasty, Balloon, Coronary; Animals; Cardiovascular Agents; Constriction, Pathologic; Coronary A

2013
First-arterial-pass dual-energy CT for assessment of myocardial blood supply: do we need rest, stress, and delayed acquisition? Comparison with SPECT.
    Radiology, 2014, Volume: 270, Issue:3

    Topics: Adenosine; Contrast Media; Coronary Artery Disease; Exercise Test; Female; Humans; Iohexol; Male; Mi

2014
Contrast layering: late clearance of contrast dye--a novel angiographic phenomenon of early atherosclerosis.
    Angiology, 2015, Volume: 66, Issue:2

    Topics: Adult; Aged; Biomarkers; Case-Control Studies; Contrast Media; Coronary Angiography; Coronary Artery

2015
Monoenergetic extrapolation of cardiac dual energy CT for artifact reduction.
    Acta radiologica (Stockholm, Sweden : 1987), 2015, Volume: 56, Issue:4

    Topics: Artifacts; Contrast Media; Coronary Artery Disease; Female; Heart; Humans; Iohexol; Male; Middle Age

2015
Direct comparison of stress- and rest-dual-energy computed tomography for detection of myocardial perfusion defect.
    The international journal of cardiovascular imaging, 2014, Volume: 30 Suppl 1

    Topics: Adenosine; Contrast Media; Coronary Angiography; Coronary Artery Disease; Coronary Stenosis; Electro

2014
Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience.
    European radiology, 2014, Volume: 24, Issue:7

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Coronary Angiography; Coronary Artery Disease; Elect

2014
Impact of diabetes duration on the extent and severity of coronary atheroma burden and long-term clinical outcome in asymptomatic type 2 diabetic patients: evaluation by Coronary CT angiography.
    European heart journal. Cardiovascular Imaging, 2015, Volume: 16, Issue:10

    Topics: Aged; Cause of Death; Contrast Media; Coronary Angiography; Coronary Artery Disease; Diabetes Mellit

2015
[Application feasibility of low tube voltage and lower iodine concentration contrast medium as well as iterative reconstruction in coronary computed tomography angiography].
    Zhonghua xin xue guan bing za zhi, 2015, Volume: 43, Issue:3

    Topics: Algorithms; Aorta; Body Mass Index; Contrast Media; Coronary Angiography; Coronary Artery Disease; F

2015
Image fusion of coronary CT angiography and cardiac perfusion MRI: a pilot study.
    European radiology, 2010, Volume: 20, Issue:5

    Topics: Aged; Algorithms; Cardiac-Gated Imaging Techniques; Contrast Media; Coronary Angiography; Coronary A

2010
Dynamic myocardial stress perfusion imaging using fast dual-source CT with alternating table positions: initial experience.
    European radiology, 2010, Volume: 20, Issue:5

    Topics: Aged; Cardiac-Gated Imaging Techniques; Contrast Media; Coronary Angiography; Coronary Artery Diseas

2010
Evaluation of coronary flow velocity reserve in homozygous familial hypercholesterolemia by transthoracic Doppler echocardiography and dual-source computed tomography.
    Ultrasound in medicine & biology, 2010, Volume: 36, Issue:10

    Topics: Adolescent; Blood Flow Velocity; Cholesterol, LDL; Contrast Media; Coronary Artery Disease; Coronary

2010
Step-and-Shoot: a new low radiation coronary computed tomography angiography technology: our initial experience with 125 consecutive asymptomatic patients.
    The Israel Medical Association journal : IMAJ, 2010, Volume: 12, Issue:11

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Coronary Angiography; Coronary Artery Disease; Femal

2010
Coronary artery plaques and myocardial ischaemia.
    European radiology, 2011, Volume: 21, Issue:8

    Topics: Aged; Analysis of Variance; Area Under Curve; Calcinosis; Contrast Media; Coronary Angiography; Coro

2011
Patients' views of cardiac computed tomography angiography compared with conventional coronary angiography.
    Journal of thoracic imaging, 2012, Volume: 27, Issue:1

    Topics: Contrast Media; Coronary Angiography; Coronary Artery Disease; Female; Humans; Iohexol; Male; Middle

2012
Critical stenosis of a right ventricle to coronary artery fistula seen at dual-source CT in a newborn with pulmonary atresia and intact ventricular septum.
    Pediatric radiology, 2011, Volume: 41, Issue:8

    Topics: Blalock-Taussig Procedure; Constriction, Pathologic; Contrast Media; Coronary Angiography; Coronary

2011
Factors influencing delay time and coronary arterial density during coronary angiography with DSCT.
    Acta radiologica (Stockholm, Sweden : 1987), 2011, Feb-01, Volume: 52, Issue:1

    Topics: Adult; Aged; Aged, 80 and over; Body Weight; Body Weights and Measures; Cardiac Output; Contrast Med

2011
Step-and-shoot prospectively ECG-gated versus retrospectively ECG-gated with tube current modulation coronary CT angiography using the 128-slice MDCT: comparison of image quality and radiation dose.
    Acta radiologica (Stockholm, Sweden : 1987), 2011, Mar-01, Volume: 52, Issue:2

    Topics: Contrast Media; Coronary Angiography; Coronary Artery Disease; Electrocardiography; Female; Humans;

2011
Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography.
    Acta radiologica (Stockholm, Sweden : 1987), 2011, Apr-01, Volume: 52, Issue:3

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Coronary Angiography; Coronary Artery Disease; Elect

2011
Coronary atherosclerosis in African American and white patients with acute chest pain: characterization with coronary CT angiography.
    Radiology, 2011, Volume: 260, Issue:2

    Topics: Acute Disease; Black or African American; Chest Pain; Chi-Square Distribution; Contrast Media; Coron

2011
Assessment of atherosclerotic plaques at coronary bifurcations with multidetector computed tomography angiography and intravascular ultrasound-virtual histology.
    European heart journal. Cardiovascular Imaging, 2012, Volume: 13, Issue:8

    Topics: Cardiac-Gated Imaging Techniques; Contrast Media; Coronary Angiography; Coronary Artery Disease; Fem

2012
Optimal timing for first-pass stress CT myocardial perfusion imaging.
    The international journal of cardiovascular imaging, 2013, Volume: 29, Issue:2

    Topics: Adenosine; Aged; Cardiac Catheterization; Contrast Media; Coronary Angiography; Coronary Artery Dise

2013
Reconstructions with identical filling (RIF) of the heart: a physiological approach to image reconstruction in coronary CT angiography.
    European radiology, 2012, Volume: 22, Issue:12

    Topics: Aged; Algorithms; Cardiac-Gated Imaging Techniques; Chi-Square Distribution; Contrast Media; Coronar

2012
Incremental prognostic value of different components of coronary atherosclerotic plaque at cardiac CT angiography beyond coronary calcification in patients with acute chest pain.
    Radiology, 2012, Volume: 264, Issue:3

    Topics: Algorithms; Calcinosis; Cardiac-Gated Imaging Techniques; Chest Pain; Contrast Media; Coronary Angio

2012
Low-dose coronary-CT angiography using step and shoot at any heart rate: comparison of image quality at systole for high heart rate and diastole for low heart rate with a 128-slice dual-source machine.
    The international journal of cardiovascular imaging, 2013, Volume: 29, Issue:3

    Topics: Adolescent; Adult; Aged; Aged, 80 and over; Artifacts; Cardiac-Gated Imaging Techniques; Contrast Me

2013
Matrix metalloproteinase-9 (MMP-9) and myeloperoxidase (MPO) levels in patients with nonobstructive coronary artery disease detected by coronary computed tomographic angiography.
    Academic radiology, 2013, Volume: 20, Issue:1

    Topics: Biomarkers; Contrast Media; Coronary Angiography; Coronary Artery Disease; Female; Humans; Iohexol;

2013
Fully automated derivation of coronary artery calcium scores and cardiovascular risk assessment from contrast medium-enhanced coronary CT angiography studies.
    European radiology, 2013, Volume: 23, Issue:3

    Topics: Algorithms; Calcinosis; Contrast Media; Coronary Angiography; Coronary Artery Disease; Female; Human

2013
Left ventricular diastolic impairment during coronary arteriography with a non-ionic contrast medium.
    Minerva cardioangiologica, 2004, Volume: 52, Issue:4

    Topics: Adult; Aged; Aged, 80 and over; Algorithms; Contrast Media; Coronary Angiography; Coronary Artery Di

2004
Coronary calcium scoring using 16-row multislice computed tomography: nonenhanced versus contrast-enhanced studies in vitro and in vivo.
    Investigative radiology, 2005, Volume: 40, Issue:3

    Topics: Calcinosis; Calcium; Calibration; Cardiomyopathies; Contrast Media; Coronary Artery Disease; Humans;

2005
Vascular profile of patients with multivessel coronary artery disease.
    International journal of cardiology, 2006, Jan-04, Volume: 106, Issue:1

    Topics: Abdomen; Aged; Aneurysm; Angiography, Digital Subtraction; Contrast Media; Coronary Angiography; Cor

2006
Different reconstruction intervals for exclusion of coronary artery calcifications by retrospectively gated MDCT.
    AJR. American journal of roentgenology, 2006, Volume: 186, Issue:1

    Topics: Calcinosis; Contrast Media; Coronary Angiography; Coronary Artery Disease; Female; Humans; Image Pro

2006
Noncalcified and calcified coronary plaque detection by contrast-enhanced multi-detector computed tomography: a study of interobserver agreement.
    Journal of the American College of Cardiology, 2006, Jan-03, Volume: 47, Issue:1

    Topics: Calcinosis; Contrast Media; Coronary Angiography; Coronary Artery Disease; Female; Humans; Iohexol;

2006
Accuracy of sixteen-slice CT scanners in detected coronary artery disease.
    Journal of the Medical Association of Thailand = Chotmaihet thangphaet, 2006, Volume: 89, Issue:1

    Topics: Adult; Aged; Aged, 80 and over; Artifacts; Contrast Media; Coronary Angiography; Coronary Artery Dis

2006
Contrast enhancement of coronary atherosclerotic plaque: a high-resolution, multidetector-row computed tomography study of pressure-perfused, human ex-vivo coronary arteries.
    Coronary artery disease, 2006, Volume: 17, Issue:6

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Coronary Artery Disease; Humans; In Vitro Techniques

2006
Nonionic contrast media induced sialadenitis following coronary angiography.
    Anadolu kardiyoloji dergisi : AKD = the Anatolian journal of cardiology, 2006, Volume: 6, Issue:3

    Topics: Angina Pectoris; Contrast Media; Coronary Angiography; Coronary Artery Disease; Diagnosis, Different

2006
Effective methods to correct contrast agent-induced errors in PET quantification in cardiac PET/CT.
    Journal of nuclear medicine : official publication, Society of Nuclear Medicine, 2007, Volume: 48, Issue:7

    Topics: Artifacts; Contrast Media; Coronary Artery Disease; Fluorodeoxyglucose F18; Heart; Humans; Image Int

2007
Impact of 64-slice cardiac computed tomographic angiography on clinical decision-making in emergency department patients with chest pain of possible myocardial ischemic origin.
    The American journal of cardiology, 2007, Nov-15, Volume: 100, Issue:10

    Topics: Acute Coronary Syndrome; Chest Pain; Contrast Media; Coronary Angiography; Coronary Artery Disease;

2007
Assessment of changes in non-calcified atherosclerotic plaque volume in the left main and left anterior descending coronary arteries over time by 64-slice computed tomography.
    The American journal of cardiology, 2008, Mar-01, Volume: 101, Issue:5

    Topics: Adult; Aged; Cholesterol, LDL; Contrast Media; Coronary Angiography; Coronary Artery Disease; Diseas

2008