Page last updated: 2024-10-29

iomeprol and Sensitivity and Specificity

iomeprol has been researched along with Sensitivity and Specificity in 144 studies

iomeprol: structure given in first source
iomeprol : A benzenedicarboxamide compound having N-substituted carbamoyl groups at the 1- and 3-positions, iodo substituents at the 2-, 4- and 6-positions and a glycoloyl(methyl)amino group at the 5-position.

Sensitivity and Specificity: Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed)

Research Excerpts

ExcerptRelevanceReference
"To investigate the volumetric iodine-uptake (VIU) changes by dual-energy CT (DECT) in assessing the response to sorafenib treated hepatocellular carcinoma (HCC) patients, compared with AASLD (American Association for the Study of Liver Diseases) and Choi criteria."9.17Quantitative therapy response assessment by volumetric iodine-uptake measurement: initial experience in patients with advanced hepatocellular carcinoma treated with sorafenib. ( Dai, X; Ganten, MK; Ganten, TM; Höh, K; Schlemmer, HP; Schmidt, B; Xu, K, 2013)
"The aim of this study was to investigate the value of third-generation dual-source dual-energy computed tomography (DECT) iodine and fat quantification in differentiating adrenal gland adenomas from metastases."7.88Iodine and Fat Quantification for Differentiation of Adrenal Gland Adenomas From Metastases Using Third-Generation Dual-Source Dual-Energy Computed Tomography. ( Albrecht, MH; Czwikla, R; Kaltenbach, B; Lenga, L; Martin, SS; Vogl, TJ; Weidinger, S; Wichmann, JL, 2018)
"To investigate the volumetric iodine-uptake (VIU) changes by dual-energy CT (DECT) in assessing the response to sorafenib treated hepatocellular carcinoma (HCC) patients, compared with AASLD (American Association for the Study of Liver Diseases) and Choi criteria."5.17Quantitative therapy response assessment by volumetric iodine-uptake measurement: initial experience in patients with advanced hepatocellular carcinoma treated with sorafenib. ( Dai, X; Ganten, MK; Ganten, TM; Höh, K; Schlemmer, HP; Schmidt, B; Xu, K, 2013)
"A total of 100 consecutive patients referred for CTPA for the exclusion of pulmonary embolism were randomized into 1 of 4 contrast material injection protocols manipulating iodine concentration and iodine delivery rate (IDR, expressed as grams of iodine per second): Iomeprol 400 at 3 mL/s (IDR = 1."5.16Optimization of contrast material delivery for dual-energy computed tomography pulmonary angiography in patients with suspected pulmonary embolism. ( Apfaltrer, P; Braunagel, M; Fink, C; Henzler, T; Krissak, R; Meyer, M; Nance, JW; Schoenberg, SO; Schoepf, UJ, 2012)
"To compare iomeprol 400 and iodixanol 320 in pulmonary artery MDCTA in subjects with suspected pulmonary embolism."5.14MDCT angiography for detection of pulmonary emboli: comparison between equi-iodine doses of iomeprol 400 mgI/mL and iodixanol 320 mgI/mL. ( Friedrich, K; Herold, C; Langenberger, H; Matzek, W; Plank, C; Schaefer-Prokop, C; Storto, ML; Wolf, F, 2009)
"The aim of this study was to investigate the value of third-generation dual-source dual-energy computed tomography (DECT) iodine and fat quantification in differentiating adrenal gland adenomas from metastases."3.88Iodine and Fat Quantification for Differentiation of Adrenal Gland Adenomas From Metastases Using Third-Generation Dual-Source Dual-Energy Computed Tomography. ( Albrecht, MH; Czwikla, R; Kaltenbach, B; Lenga, L; Martin, SS; Vogl, TJ; Weidinger, S; Wichmann, JL, 2018)
"One-hundred nineteen consecutive patients undergoing pulmonary CTA for suspected pulmonary embolism were included and imaged on a 128-row computed tomography scanner at 100 kVp using highly concentrated contrast material (85 mL Iomeprol; 400 mg iodine/mL)."3.80Evaluation of a high iodine delivery rate in combination with low tube current for dose reduction in pulmonary computed tomography angiography. ( Aissa, J; Antoch, G; Heusch, P; Krix, M; Kröpil, P; Lanzman, RS; Schimmöller, L, 2014)
"To predict the T stage of nonrectal colon cancer using contrast-enhanced computed tomography colonography."2.78Contrast-enhanced computed tomography colonography in preoperative distinction between T1-T2 and T3-T4 staging of colon cancer. ( Bosari, S; Ceretti, AP; Cornalba, GP; Flor, N; Mezzanzanica, M; Peri, M; Rigamonti, P; Rocco, EG; Sardanelli, F; Soldi, S, 2013)
"Initial CT scans of 130 patients with abdominal aortic aneurysms (AAAs) were retrospectively reviewed."1.42Identification of predictive CT angiographic factors in the development of high-risk type 2 endoleaks after endovascular aneurysm repair in patients with infrarenal aortic aneurysms. ( Bulla, K; Dudeck, O; Halloul, Z; Herzog, L; Löwenthal, D; Meyer, F; Pech, M; Ricke, J; Rogits, B; Weston, S, 2015)
"Type of malignancy and metastases were reported for PE-positive patients."1.42Contrast enhanced chest-MDCT in oncologic patients. Prospective evaluation of the prevalence of incidental pulmonary embolism and added value of thin reconstructions. ( Colombo, B; Cornalba, G; Flor, N; Lombardi, MA; Luciani, A; Tresoldi, S, 2015)
"• Patients with no filling defect or thrombus in MDCT in the LA/LAA region are unlikely to have thrombus and may undergo PVI without TEE."1.40Split-bolus single-phase cardiac multidetector computed tomography for reliable detection of left atrial thrombus: comparison to transesophageal echocardiography. ( Hasenfuß, G; Lotz, J; Schneider, S; Schwarz, A; Sohns, C; Sohns, JM; Staab, W; Vollmann, D; Zabel, M; Zwaka, PA, 2014)
"Cerebral vasospasm (CV) following subarachnoid hemorrhage (SAH) implies high risk for secondary ischemia."1.40Volume perfusion CT (VPCT) for the differential diagnosis of patients with suspected cerebral vasospasm: qualitative and quantitative analysis of 3D parameter maps. ( Dolatowski, K; Frölich, AM; Haberland, U; Klotz, E; Knauth, M; Malinova, V; Mielke, D; Schramm, P; Schramm, R, 2014)
"Information given by CE-CTC concerning colorectal cancer location and synchronous colonic cancers and polyps changed the laparoscopic surgical strategy in almost 14 % of patients."1.39Impact of contrast-enhanced computed tomography colonography on laparoscopic surgical planning of colorectal cancer. ( Ceretti, AP; Cornalba, GP; Flor, N; Mangiavillano, B; Mezzanzanica, M; Peri, M; Rigamonti, P; Sardanelli, F; Soldi, S; Tresoldi, S, 2013)
"Endoleaks were detected visually in all scan phases; the magnitude of enhancement was assessed by using region-of-interest measurements in the aorta and the detectable endoleaks."1.39Dynamic CT angiography after abdominal aortic endovascular aneurysm repair: influence of enhancement patterns and optimal bolus timing on endoleak detection. ( Andres, C; Foldyna, B; Grothoff, M; Gutberlet, M; Hoffmann, J; Lehmkuhl, L; Lücke, C; Nitzsche, S; Scheinert, D; Schmidt, A; Ulrich, M, 2013)
"Iomeprol was administered with a continuous infusion protocol; the other agents as a bolus."1.39A comparative analysis of water-soluble and blood-pool contrast agents for in vivo vascular imaging with micro-CT. ( Kuhn, GA; Müller, R; Nebuloni, L, 2013)
"Acute cholecystitis is associated with myriad suggestive findings on 64-section helical CT."1.39Acute cholecystitis: quantitative and qualitative evaluation with 64-section helical CT. ( Boudiaf, M; Dohan, A; Eveno, C; Gayat, E; Hoeffel, C; Malgras, B; Pautrat, K; Soyer, P, 2013)
"In each patient, carotid artery stenosis was quantified using the mm-method."1.38Carotid artery stenosis at MSCT: is there a threshold in millimeters that determines clinical significance? ( Mallarini, G; Montisci, R; Saba, L; Sanfilippo, R, 2012)
"Forty patients with suspected carotid artery stenosis received head and neck dual-energy CT angiography as part of their pre-interventional workup."1.38Evaluation of computer-assisted quantification of carotid artery stenosis. ( Biermann, C; Claussen, CD; Heuschmid, M; Kasperek, B; Thomas, C; Tsiflikas, I, 2012)
"C-arm CT helps detection of hepatocellular carcinoma (HCC) during interventional (TACE) treatment."1.38Diagnostic accuracy of C-arm CT during selective transcatheter angiography for hepatocellular carcinoma: comparison with intravenous contrast-enhanced, biphasic, dynamic MDCT. ( Higashihara, H; Hori, M; Kim, T; Maeda, N; Nakamoto, A; Onishi, H; Osuga, K; Tomiyama, N; Tsuboyama, T, 2012)
"Noninvasive imaging of cerebral aneurysms is still considered inferior to conventional angiography."1.38Angiographic CT with intravenous contrast injection compared with conventional rotational angiography in the diagnostic work-up of cerebral aneurysms. ( Doerfler, A; Ganslandt, O; Gölitz, P; Knossalla, F; Ott, S; Saake, M; Struffert, T, 2012)
"Sensitivity and specificity were 94."1.36Role of 64-slice cardiac computed tomography in the evaluation of patients with non-ST-elevation acute coronary syndrome. ( Acampora, V; Arganini, C; Bazzocchi, G; De Angelis, B; Martuscelli, E; Patrei, A; Romagnoli, A; Romeo, F; Simonetti, G; Sperandio, M, 2010)
"In total, 32 patients with colorectal cancer and liver metastases were followed by an average of 2."1.36Suitability of semi-automated tumor response assessment of liver metastases using a dedicated software package. ( de Greiff, A; Forsting, M; Kalkmann, J; Ladd, SC; Stattaus, J, 2010)
"Thirty-nine patients with esophageal cancer proved by means of endoscopy, underwent preoperative TNM staging with dynamic CT of the chest and abdomen with the aid of 3D rendering."1.333D CT protocol in the assessment of the esophageal neoplastic lesions: can it improve TNM staging? ( Anzidei, M; Grazhdani, H; Iafrate, F; Laghi, A; Panebianco, V; Passariello, R; Petroni, M, 2006)
"Evaluation of solitary pulmonary nodules by analyzing combined wash-in and washout characteristics at dynamic contrast-enhanced multi-detector row CT showed 92% accuracy for distinguishing benign nodules from malignant nodules."1.33Solitary pulmonary nodule: characterization with combined wash-in and washout features at dynamic multi-detector row CT. ( Chung, MJ; Jeong, SY; Jeong, YJ; Kim, H; Kim, S; Kwon, OJ; Lee, KS; Shim, SS, 2005)
"The sensitivities for segmental pulmonary embolism were 86%, 83%, and 97%, respectively."1.33Acute pulmonary embolism to the subsegmental level: diagnostic accuracy of three MRI techniques compared with 16-MDCT. ( Bachmann, G; Kluge, A; Luboldt, W, 2006)
"One hundred thirty-one patients with solitary pulmonary nodules underwent unenhanced thin-section CT, followed by dynamic helical CT (throughout the nodule for 30 mm along the z-axis [13 images] and at 20-second intervals for 3 minutes [130 images total]) after intravenous injection of 120 mL of contrast medium."1.32Solitary pulmonary nodules: dynamic enhanced multi-detector row CT study and comparison with vascular endothelial growth factor and microvessel density. ( Han, J; Jeong, YJ; Kim, EA; Kim, H; Kim, S; Kwon, OJ; Lee, KS; Yi, CA, 2004)

Research

Studies (144)

TimeframeStudies, this research(%)All Research%
pre-19900 (0.00)18.7374
1990's1 (0.69)18.2507
2000's52 (36.11)29.6817
2010's90 (62.50)24.3611
2020's1 (0.69)2.80

Authors

AuthorsStudies
Muenzfeld, H1
Mahjoub, S1
Roehle, R1
Pelzer, U1
Bahra, M1
Boening, G1
Hamm, B1
Geisel, D1
Auer, TA1
Godt, JC1
Eken, T1
Schulz, A1
Øye, K1
Hagen, T1
Dormagen, JB1
Rösch, J1
Lang, S1
Gölitz, P2
Kallmünzer, B1
Rössler, K1
Doerfler, A2
Struffert, T3
Martin, SS1
Weidinger, S1
Czwikla, R1
Kaltenbach, B1
Albrecht, MH1
Lenga, L1
Vogl, TJ5
Wichmann, JL2
Schäfer, JC1
Haubenreisser, H1
Meyer, M5
Grüttner, J1
Walter, T1
Borggrefe, M1
Schoepf, JU1
Nance, JW3
Schönberg, SO2
Henzler, T5
Noda, Y1
Goshima, S1
Kawada, H1
Kawai, N1
Miyoshi, T1
Matsuo, M1
Bae, KT1
Infante, T2
Forte, E2
Punzo, B1
Cademartiri, F9
Cavaliere, C2
Soricelli, A2
Salvatore, M2
Napoli, C1
García Vicente, AM1
Domínguez Ferreras, E1
Sánchez Pérez, V1
Poblete García, VM1
Villa Guzmán, JC1
Jiménez Aragón, F1
Pineda Pineda, MD1
Molino Trinidad, C1
Soriano Castrejón, Á1
Flor, N3
Mezzanzanica, M2
Rigamonti, P2
Rocco, EG1
Bosari, S1
Ceretti, AP2
Soldi, S2
Peri, M2
Sardanelli, F2
Cornalba, GP2
Naulet, P1
Wassel, J1
Gervaise, A1
Blum, A1
Kim, JW1
Goo, HW1
Tresoldi, S2
Mangiavillano, B1
Maffione, AM1
Rampin, L1
Blickman, JG1
Rubello, D1
Lehmkuhl, L1
Andres, C1
Lücke, C1
Hoffmann, J1
Foldyna, B1
Grothoff, M1
Nitzsche, S1
Schmidt, A1
Ulrich, M1
Scheinert, D1
Gutberlet, M1
Huber, AM1
Leber, V1
Gramer, BM1
Muenzel, D1
Leber, A1
Rieber, J1
Schmidt, M1
Vembar, M1
Hoffmann, E1
Rummeny, E1
Vogler, N1
Fink, C4
Schoepf, UJ3
Bauer, RW3
Doss, M1
Stock, W1
Lehnert, T2
Bodelle, B1
Frellesen, C1
Kerl, JM3
Ba-Ssalamah, A2
Muin, D1
Schernthaner, R1
Kulinna-Cosentini, C1
Bastati, N1
Stift, J1
Gore, R1
Mayerhoefer, ME1
Nebuloni, L1
Kuhn, GA1
Müller, R1
Geffroy, Y1
Boulay-Coletta, I1
Jullès, MC1
Nakache, S1
Taourel, P1
Zins, M1
Yerramasu, A1
Lahiri, A1
Venuraju, S1
Dumo, A1
Lipkin, D1
Underwood, SR1
Rakhit, RD1
Patel, DJ1
Pontone, G3
Bertella, E2
Mushtaq, S2
Loguercio, M1
Cortinovis, S2
Baggiano, A1
Conte, E1
Annoni, A2
Formenti, A2
Beltrama, V1
Guaricci, AI1
Andreini, D3
Azzouz, M1
Rømsing, J1
Thomsen, HS2
Min, JH1
Kim, SM2
Lee, S1
Choi, JH2
Chang, SA1
Choe, YH2
Kim, EK1
Song, YB1
Hahn, JY1
Choi, SH1
Gwon, HC1
Lee, SH1
Oh, JK1
Staab, W1
Sohns, C1
Zwaka, PA1
Sohns, JM1
Schwarz, A1
Schneider, S1
Vollmann, D1
Zabel, M1
Hasenfuß, G1
Lotz, J1
Schabel, C1
Bongers, M1
Sedlmair, M1
Korn, A2
Grosse, U1
Mangold, S1
Claussen, CD7
Thomas, C3
Swanberg, J1
Nyman, R1
Magnusson, A1
Wanhainen, A1
Dolatowski, K1
Malinova, V1
Frölich, AM1
Schramm, R1
Haberland, U1
Klotz, E1
Mielke, D1
Knauth, M1
Schramm, P1
Heusch, P1
Lanzman, RS1
Aissa, J1
Schimmöller, L1
Antoch, G2
Krix, M1
Kröpil, P1
Löwenthal, D1
Herzog, L1
Rogits, B1
Bulla, K1
Weston, S1
Meyer, F1
Halloul, Z1
Pech, M1
Ricke, J1
Dudeck, O1
Mileto, A1
Ramirez-Giraldo, JC1
Marin, D2
Alfaro-Cordoba, M1
Eusemann, CD1
Scribano, E1
Blandino, A1
Mazziotti, S1
Ascenti, G1
Ramgren, B1
Siemund, R1
Nilsson, OG1
Höglund, P1
Larsson, EM1
Abul-Kasim, K1
Björkman-Burtscher, IM1
Gibaldi, A1
Barone, D1
Gavelli, G2
Malavasi, S1
Bevilacqua, A1
Hong, Y1
Shin, S1
Park, HB1
Lee, BK1
Arsanjani, R1
ó Hartaigh, B1
Ha, S1
Jang, Y1
Jeon, B1
Jung, S1
Park, SI1
Sung, JM1
Shim, H1
Chang, HJ1
Medjek, M1
Hackx, M1
Ghaye, B1
De Maertelaer, V1
Gevenois, PA1
Luciani, A1
Lombardi, MA1
Colombo, B1
Cornalba, G1
Anzidei, M3
Di Martino, M2
Sacconi, B1
Saba, L2
Boni, F1
Zaccagna, F2
Geiger, D2
Kirchin, MA2
Napoli, A4
Bezzi, M1
Catalano, C5
Wuest, W2
May, MS1
Brand, M1
Bayerl, N1
Krauss, A1
Uder, M3
Lell, M2
Ochtrop, TA1
Szynaka, M1
Kopp, AF6
Ko, BS1
Wong, DT1
Nørgaard, BL1
Leong, DP1
Cameron, JD1
Gaur, S1
Marwan, M2
Achenbach, S4
Kuribayashi, S1
Kimura, T1
Meredith, IT1
Seneviratne, SK1
Utano, K1
Nagata, K1
Honda, T1
Mitsushima, T1
Yasuda, T1
Kato, T1
Horita, S1
Asano, M1
Oda, N1
Majima, K1
Kawamura, Y1
Hirayama, M1
Watanabe, N1
Kanazawa, H1
Lefor, AK1
Sugimoto, H1
Aiello, M1
Inglese, M1
Tedeschi, C1
Utsunomiya, D2
Yamashita, Y2
Okumura, S1
Urata, J2
Heusner, TA1
Kuehl, H1
Veit-Haibach, P1
Hahn, S1
Boy, C1
Forsting, M2
Bockisch, A1
Mühlenbruch, G2
Behrendt, FF2
Eddahabi, MA1
Knackstedt, C1
Stanzel, S1
Das, M2
Seidensticker, P3
Günther, RW2
Wildberger, JE1
Mahnken, AH3
Chae, EJ1
Song, JW1
Seo, JB2
Krauss, B2
Jang, YM1
Song, KS1
Reimann, AJ2
Tsiflikas, I4
Brodoefel, H3
Scheuering, M1
Rinck, D1
Heuschmid, M6
Zunker, C2
Anders, K3
Ropers, D3
Bautz, W1
Kuettner, A3
Harieaswar, S1
Rajesh, A1
Griffin, Y1
Tyagi, R1
Morgan, B1
Balvay, D1
Troprès, I1
Billet, R1
Joubert, A1
Péoc'h, M1
Cuenod, CA1
Le Duc, G1
Plumhans, C1
Keil, S1
Mutscher, C1
Diederich, S1
Krug, KB1
Bovenschulte, H1
Geissler, HJ1
Flesch, M1
Schneider, T1
Brackrogge, D1
Reiter, H1
Heppelmann, I1
Christ, H1
Fischer, JH1
Lackner, KJ1
Wüst, W1
May, M1
Ohlmann, S1
Nowak, R1
Daliri, A1
Michulla, R1
Froelich, JJ1
Heye, S2
Maleux, G1
Claes, K1
Kuypers, D1
Oyen, R1
Baski, M1
Di Giorgio, A1
Sibio, S1
Passariello, R5
Bisdas, S2
Baghi, M1
Wagenblast, J1
Bisdas, T1
Thng, CH1
Mack, MG1
Koh, TS1
Ernemann, U2
Stagnaro, N1
Della Latta, D1
Chiappino, D1
Ketelsen, D1
Reimann, A2
Meier-Meitinger, M1
Alibek, S1
Baum, U1
Artmann, A1
Enayati, S1
Ratzenböck, M1
Schwarz, M3
Weber, T1
Eber, B1
Loewe, C1
Becker, CR2
Berletti, R1
Cametti, CA1
Caudron, J1
Coudyzer, W1
De Mey, J1
Favat, M1
Heautot, JF1
Hittinger, M1
Larralde, A1
Lestrat, JP1
Marangoni, R1
Nieboer, K1
Reimer, P1
Schernthaner, M1
Lammer, J2
Engelhorn, T1
Eyupoglu, IY1
Brünner, H1
Kalender, W1
Dörfler, A1
Nielsen, YW1
Eiberg, JP1
Løgager, VB1
Just, S1
Schroeder, TV1
Romagnoli, A1
Martuscelli, E1
Sperandio, M1
Arganini, C1
De Angelis, B1
Acampora, V1
Patrei, A1
Bazzocchi, G1
Romeo, F1
Simonetti, G1
Martini, C2
Maffei, E6
Palumbo, A4
Weustink, A1
Baks, T2
Moelker, A1
Dunker, D1
Emiliano, E1
Cuttone, A1
Mollet, N3
Krestin, G1
De Feyter, P1
Gahide, G1
Bommart, S1
Demaria, R1
Sportouch, C1
Dambia, H1
Albat, B1
Vernhet-Kovacsik, H1
Kalkmann, J1
Ladd, SC1
de Greiff, A1
Stattaus, J1
Holzapfel, K1
Reiser-Erkan, C1
Fingerle, AA2
Erkan, M1
Eiber, MJ1
Rummeny, EJ2
Friess, H1
Kleeff, J1
Gaa, J1
Reichert, M1
Krissak, R2
Haneder, S1
Schoenberg, SO3
De Cecco, CN1
Buffa, V1
Fedeli, S1
Luzietti, M1
Vallone, A1
Ruopoli, R1
Miele, V1
Rengo, M1
Paolantonio, P1
Maurizi Enrici, M1
Laghi, A2
David, V1
Tamura, Y1
Sakamoto, T1
Hirai, T1
Nishiharu, T1
Fischer, N1
Burkhard, T1
Larson, MC1
Ackermann, H2
Kraus, B1
Bernhardt, D1
Vega-Higuera, F1
Grassi, R1
Rambaldi, PF1
Di Grezia, G1
Mansi, L1
Cuccurullo, V1
Cirillo, A1
Riegler, G1
Cappabianca, S1
Rotondo, A1
Boussel, L1
Cakmak, S1
Wintermark, M1
Nighoghossian, N1
Loffroy, R1
Coulon, P1
Derex, L1
Cho, TH1
Douek, PC1
van der Bijl, N1
Joemai, RM1
Geleijns, J1
Bax, JJ1
Schuijf, JD1
de Roos, A1
Kroft, LJ1
Sanfilippo, R1
Montisci, R1
Mallarini, G1
Attinà, D1
Valentino, M1
Galiè, N1
Modolon, C1
Buia, F1
de Luca, F1
Bacchi-Reggiani, ML1
Zompatori, M1
Bartorelli, AL2
Trabattoni, D1
Ballerini, G2
Agostoni, P2
Fiorentini, C1
Pepi, M2
Koelblinger, C2
Goetzinger, P1
Puchner, S1
Weber, M2
Sahora, K1
Scharitzer, M1
Plank, C3
Schima, W2
Henes, FO1
Groth, M1
Begemann, PG1
Bley, T1
Adam, G1
Regier, M1
Apfaltrer, P2
Braunagel, M1
Ichikawa, T1
Motosugi, U1
Morisaka, H1
Sou, H1
Onohara, K1
Sano, K1
Araki, T1
Tanaka, J1
Kozawa, E1
Inoue, K1
Okamoto, Y1
Toya, M1
Sato, Y1
Biermann, C1
Kasperek, B1
Lembcke, A1
Durmus, T1
Westermann, Y1
Geigenmueller, A1
Claus, B1
Butler, C1
Thiele, H1
Meier, C1
Barraza, JM1
Dinter, DJ1
Hohenberger, P1
Perini, P1
Sediri, I1
Midulla, M1
Delsart, P1
Mouton, S1
Gautier, C1
Pruvo, JP1
Haulon, S1
Cavallo Marincola, B1
Zini, C1
Brachetti, G1
Cartocci, G1
Fanelli, F1
Rossi, A1
Lario, C1
Castiglione Morelli, M1
Clemente, A1
Gentile, G2
Arcadi, T1
Seitun, S1
Catalano, O1
Aldrovandi, A3
Higashihara, H1
Osuga, K1
Onishi, H1
Nakamoto, A1
Tsuboyama, T1
Maeda, N1
Hori, M1
Kim, T1
Tomiyama, N1
Giesel, FL1
Kratochwil, C1
Mehndiratta, A1
Wulfert, S1
Moltz, JH1
Zechmann, CM1
Kauczor, HU1
Haberkorn, U1
Ley, S1
Knossalla, F1
Saake, M1
Ott, S1
Ganslandt, O1
Stabile Ianora, AA1
Moschetta, M1
Pedote, P1
Scardapane, A1
Angelelli, G1
Jost, G1
Kuhl, C1
Pietsch, H1
Shimamoto, H1
Chindasombatjaroen, J1
Kakimoto, N1
Kishino, M1
Murakami, S1
Furukawa, S1
Bakhshi, S1
Radhakrishnan, V1
Sharma, P1
Kumar, R1
Thulkar, S1
Vishnubhatla, S1
Dhawan, D1
Malhotra, A1
Sommer, WH1
Haack, M1
Rubin, GD1
Weidenhagen, R1
Schwarz, F1
Nikolaou, K1
Reiser, MF1
Johnson, TR1
Clevert, DA1
Millon, D1
Derelle, AL1
Omoumi, P1
Tisserand, M1
Schmitt, E1
Foscolo, S1
Anxionnat, R1
Bracard, S1
Schuhbäck, A1
Gauss, S1
Muschiol, G1
Schneider, C1
Rixe, J1
Hamm, C1
Daniel, WG1
Noël, PB1
Bendik, E1
Münzel, D1
Schneider, A1
Goshen, L1
Gringauz, A1
Lamash, Y1
Vlassenbroek, A1
Dobritz, M1
Berger-Kulemann, V1
Wolf, F2
Dai, X1
Schlemmer, HP1
Schmidt, B1
Höh, K1
Xu, K1
Ganten, TM1
Ganten, MK1
La Grutta, L3
Galia, M3
Lo Re, G2
Grassedonio, E1
Coppolino, F1
Maresi, E1
Lo Casto, A1
Midiri, M7
Lacquaniti, A1
Buemi, F1
Lupica, R1
Giardina, C1
Murè, G1
Arena, A1
Visalli, C1
Baldari, S1
Aloisi, C1
Buemi, M1
Soyer, P1
Hoeffel, C1
Dohan, A1
Gayat, E1
Eveno, C1
Malgras, B1
Pautrat, K1
Boudiaf, M1
Yi, CA2
Lee, KS3
Kim, EA1
Han, J1
Kim, H2
Kwon, OJ2
Jeong, YJ2
Kim, S2
Marano, R1
Luccichenti, G1
Runza, G5
Belgrano, M1
Gualerzi, M1
Brambilla, L1
Coruzzi, P1
Panebianco, V1
Grazhdani, H2
Iafrate, F1
Petroni, M1
Jeong, SY1
Chung, MJ2
Shim, SS1
Mollet, NR4
McFadden, EP1
Flohr, TG1
Ohnesorge, B1
de Feyter, PJ2
Krestin, GP2
Pozzi Mucelli, RM1
Como, G1
Del Frate, C1
Iuri, D1
Furlan, A1
Al-Grhiw, E1
Bazzocchi, M1
Kluge, A1
Luboldt, W1
Bachmann, G1
Iezzi, R2
Cotroneo, AR2
Filippone, A1
Di Fabio, F1
Quinto, F1
Colosimo, C1
Bonomo, L1
Pilleul, F1
Penigaud, M1
Milot, L1
Saurin, JC1
Chayvialle, JA1
Valette, PJ1
Dikkers, R1
Willems, TP1
Tio, RA1
Anthonio, RL1
Zijlstra, F1
Oudkerk, M1
Bartolotta, TV2
Somers, P1
Knaapen, M1
Verheye, S1
Hamers, R1
Bruining, N1
Buhmann, S1
Herzog, P1
Liang, J1
Wolf, M1
Salganicoff, M1
Kirchhoff, C1
Reiser, M1
Becker, CH1
Magini, A1
Quaglia, C1
Nobili, E1
Stiller, W1
Kobayashi, M1
Koike, K1
Stampfl, U1
Richter, GM1
Semmler, W1
Kiessling, F1
Jeon, TY1
Lee, JH1
Kim, YK1
Mazzeo, S1
Cappelli, C1
Caramella, D1
Belcari, A1
Forasassi, F1
Battaglia, V1
Giannini, A1
Pasquariello, R1
Pallocci, S1
Caproni, G1
Marcocci, C1
Pinchera, A1
Miccoli, P1
Bartolozzi, C1
Pascali, D1
Merlino, B1
Storto, ML2
Silvennoinen, HM1
Hamberg, LM1
Valanne, L1
Hunter, GJ1
Klumpp, B1
Schumacher, F1
Teufel, M1
Beck, T1
Burgstahler, C2
Schröder, S1
Taibbi, A1
Lagalla, R1
De Maria, M1
Carbone, I2
Francone, M2
Algeri, E2
Granatelli, A1
Abada, HT1
Golzarian, J1
Malagò, R2
Alberghina, F1
Brambilla, V1
Menozzi, A2
Vignali, L2
Casolo, G1
Lezoche, R1
Mirabelli, F1
Gaudio, C1
Calabrese, FA1
Mangini, M1
Carrafiello, G1
Laganà, D1
Palma, L1
Novario, R1
Dionigi, G1
Neri, C1
Fugazzola, C1
Schroeder, S1
Langenberger, H1
Friedrich, K1
Matzek, W1
Schaefer-Prokop, C1
Herold, C1
Notarangelo, F1
Ugo, F1
Lina, D1
Solinas, E1
Reverberi, C1
Cervellin, G1
Ardissino, D1
Kitajima, K1
Murakami, K1
Yamasaki, E1
Domeki, Y1
Kaji, Y1
Fukasawa, I1
Inaba, N1
Suganuma, N1
Sugimura, K1
Surlan-Popovic, K1
Didanovic, V1
Bartalena, T1
Oboldi, D1
Guidalotti, PL1
Rinaldi, MF1
Bertaccini, P1
Napoli, G1
Körber, HJ1
Fischer, U1
Vosshenrich, R1
Loubeyre, P1
Debard, I1
Nemoz, C1
Minh, VA1
Hahn, U1
König, CW1
Miller, S1
Brehm, B1
Nieman, K1
Rensing, BJ1
van Geuns, RJ1
Munne, A1
Ligthart, JM1
Pattynama, PM1
Serruys, PW1

Clinical Trials (10)

Trial Overview

TrialPhaseEnrollmentStudy TypeStart DateStatus
Randomized Controlled Trial to Evaluate the Cost and Clinical Effectiveness of CT Coronary Angiography in Patients With Stable Angina Pectoris (RADICAL Trial)[NCT01464203]600 participants (Anticipated)Interventional2009-02-28Recruiting
Impact of Stress Cardiac Computed Tomography Myocardial Perfusion on Downstream Resources and PROgnosis in Patients With Suspected or Known Coronary Artery Disease: a Multicenter International Study[NCT03976921]2,000 participants (Anticipated)Interventional2019-06-01Not yet recruiting
Prospective Clinical Trial to Investigate Adverse Reactions to MR and CT-examinations (Enhanced and Unenhanced)[NCT01132339]1,467 participants (Actual)Observational2010-05-31Completed
HeartFlowNXT - HeartFlow Analysis of Coronary Blood Flow Using Coronary CT Angiography: NeXt sTeps[NCT01757678]276 participants (Actual)Interventional2012-09-30Completed
Optimized Response Assessment of Gastrointestinal Stromal Tumors Using Dual-Energy CT: Prospective Multicenter-Multinational Trial in Patients Undergoing Targeted Therapy With a TKI Inhibitor.[NCT03404076]93 participants (Actual)Observational2014-12-01Completed
"Evaluation of Multidetector Raw Computerized Tomography in the Etiological Analysis of Acute Ischemic Stroke: the COCASE Protocol."[NCT00708188]49 participants (Actual)Interventional2008-03-31Completed
Prospective Multicenters Clinical Cohort Study on Efficacy and Safety of Stratified Treatment for Chinese Children With Burkitt Lymphoma/Diffuse Large B-cell Lymphoma[NCT03958916]500 participants (Anticipated)Observational [Patient Registry]2017-05-05Recruiting
Intravenous vs. Oral Hydration to Reduce the Risk of Post-Contrast Acute Kidney Injury After Intravenous Contrast-Enhanced Computed Tomography in Patients With Severe Chronic Kidney Disease (ENRICH): A Randomized Controlled Trial[NCT05283512]254 participants (Anticipated)Interventional2022-04-20Recruiting
[NCT00172575]60 participants Observational2004-12-31Recruiting
Computer tomoGRaphy guidEd invasivE Coronary Angiography in patiEnts With a Previous Coronary Artery Bypass Graft Surgery Trial[NCT04631809]225 participants (Actual)Interventional2020-10-30Completed
[information is prepared from clinicaltrials.gov, extracted Sep-2024]

Trial Outcomes

AUC of FFRct Versus Coronary CTA for Demonstration of Ischemia (≤0.80) on a Per-patient Basis

The primary statistical measure will be the area under the receiver operating characteristic curve (AUC of ROC) of a patient-based model to detect hemodynamically significant obstruction. ROC graphs the change in sensitivity as the cut-point for positive/negative diagnosis moves from its lower to upper limit. FFR is used as the reference standard to determine the presence or absence of hemodynamic obstruction. For FFR, hemodynamically-significant obstruction of a coronary artery is defined as an FFR≤0.80 in any major epicardial coronary artery segment with diameter ≥2.0 mm during adenosine-mediated hyperemia. For cCTA, hemodynamically-significant obstruction of a coronary artery is defined as a stenosis >50% . FFRCT will be calculated for each patient as the minimum FFRCT in any coronary artery segment . cCTA stenosis will be calculated for each patient as the highest cCTA stenosis category for any vessel all measurements will take place only in segments with diameter ≥2.0 mm. (NCT01757678)
Timeframe: 1 day; Outcome measures were comparing FFRct to FFR. Incident time for FFR was dependent on the length of time on the cath procedure. FFRct was done remotely at HeartFlow's processing center in Redwood City with a turnaround time of 24 hours from CT scan.

Interventionprobablility (Number)
FFRct vs. FFR.90
cCTA vs. FFR.81

AUC of FFRct Versus Coronary CTA for Demonstration of Ischemia (≤0.80) on a Per-vessel Basis

(NCT01757678)
Timeframe: 1 day

Interventionprobability (Number)
FFRct vs. FFR.93
cCTA vs. FFR.79

Per Vessel Diagnostic Performance of FFRct, Coronary CTA, and ICA

(NCT01757678)
Timeframe: 1 day; Outcome measures were comparing FFRct to FFR. Incident time for FFR was dependent on the length of time on the cath procedure. FFRct was done remotely at HeartFlow's processing center in Redwood City with a turnaround time of 24 hours from CT scan.

Interventionpercentage of tests (Number)
Accuracy: ICA Stenosis >50%Accuracy: FFRct ≤ 0.80Accuracy: Coronary CTA Stenosis >50%Sensitivity: ICA Stenosis >50%Sensitivity: FFRct ≤ 0.80Sensitivity: Coronary CTA Stenosis >50%Specificity: ICA Stenosis >50%Specificity: FFRct ≤ 0.80Specificity: Coronary CTA Stenosis >50%Positive Predictive Value: ICA Stenosis >50%Positive Predictive Value: FFRct ≤ 0.80Positive Predictive Value: cCTA Stenosis >50%Negative Predictive Value: ICA Stenosis >50%Negative Predictive Value: FFRct ≤ 0.80Negative Predictive Value: cCTA Stenosis >50%
Standard of Care: FFR and ICA828665558483908660586133889592

Per-Patient Analysis: Diagnostic Performance of FFRct, Coronary CTA, and ICA

(NCT01757678)
Timeframe: 1 day; Outcome measures were comparing FFRct to FFR. Incident time for FFR was dependent on the length of time on the cath procedure. FFRct was done remotely at HeartFlow's processing center in Redwood City with a turnaround time of 24 hours from CT scan.

Interventionpercentage of tests (Number)
Accuracy: ICA Stenosis >50%Accuracy: FFRct ≤ 0.80Accuracy: Coronary CTA Stenosis >50%Sensitivity: ICA Stenosis >50%Sensitivity: FFRct ≤ 0.80Sensitivity: Coronary CTA Stenosis >50%Specificity: ICA Stenosis >50%Specificity: FFRct ≤ 0.80Specificity: Coronary CTA Stenosis >50%Positive Predictive Value: ICA Stenosis >50%Positive Predictive Value: FFRct ≤ 0.80Positive Predictive Value: cCTA Stenosis >50%Negative Predictive Value: ICA Stenosis >50%Negative Predictive Value: FFRct ≤ 0.80Negative Predictive Value: cCTA Stenosis >50%
Standard of Care: FFR and ICA778153648694837934636540839392

Per-Patient Diagnostic Performance of FFRct in Patients With Intermediate Stenosis Severity (30%-70%) According to Coronary CTA

(NCT01757678)
Timeframe: 1 day; Outcome measures were comparing FFRct to FFR. Incident time for FFR was dependent on the length of time on the cath procedure. FFRct was done remotely at HeartFlow's processing center in Redwood City with a turnaround time of 24 hours from CT scan.

Interventionpercentage of tests (Number)
Accuracy: FFRct ≤ 0.80Accuracy: Coronary CTA Stenosis > 50%Sensitivity: FFRct ≤ 0.80Sensitivity: Coronary CTA Stenosis >50%Specificity: FFRct ≤ 0.80Specificity: Coronary CTA Stenosis > 50%Positive Predictive Value: FFRct ≤ 0.80Positive Predictive Value: cCTA Stenosis > 50%Negative Predictive Value: FFRct ≤ 0.80Negative Predictive Value: cCTA Stenosis > 50%
Standard of Care: FFR and ICA80518593793263379291

Trials

22 trials available for iomeprol and Sensitivity and Specificity

ArticleYear
Response assessment of colorectal liver metastases with contrast enhanced CT/18F-FDG PET.
    European journal of radiology, 2013, Volume: 82, Issue:6

    Topics: Adult; Aged; Colorectal Neoplasms; Contrast Media; Female; Fluorodeoxyglucose F18; Humans; Image Enh

2013
Contrast-enhanced computed tomography colonography in preoperative distinction between T1-T2 and T3-T4 staging of colon cancer.
    Academic radiology, 2013, Volume: 20, Issue:5

    Topics: Adult; Aged; Aged, 80 and over; Colonic Neoplasms; Colonography, Computed Tomographic; Contrast Medi

2013
Coronary artery disease: diagnostic accuracy of CT coronary angiography--a comparison of high and standard spatial resolution scanning.
    Radiology, 2014, Volume: 271, Issue:3

    Topics: Algorithms; Artifacts; Contrast Media; Coronary Angiography; Coronary Artery Disease; Female; Humans

2014
Fluctuations in eGFR in relation to unenhanced and enhanced MRI and CT outpatients.
    European journal of radiology, 2014, Volume: 83, Issue:6

    Topics: Adolescent; Adult; Aged; Aged, 80 and over; Ambulatory Care; Artifacts; Contrast Media; Denmark; Fem

2014
Nonlinear image blending for dual-energy MDCT of the abdomen: can image quality be preserved if the contrast medium dose is reduced?
    AJR. American journal of roentgenology, 2014, Volume: 203, Issue:4

    Topics: Abdominal Neoplasms; Adult; Aged; Aged, 80 and over; Algorithms; Contrast Media; Dose-Response Relat

2014
Demonstration of the Adamkiewicz artery in patients with descending or thoracoabdominal aortic aneurysm: optimization of contrast-medium application for 64-detector-row CT angiography.
    European radiology, 2008, Volume: 18, Issue:11

    Topics: Adult; Aged; Aged, 80 and over; Angiography; Aortic Aneurysm, Thoracic; Contrast Media; Female; Huma

2008
Functional cardiac CT imaging: a new contrast application strategy for a better visualization of the cardiac chambers.
    European journal of radiology, 2008, Volume: 68, Issue:3

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Female; Heart Ventricles; Humans; Iopamidol; Male; M

2008
Contrast enhancement in chest multidetector computed tomography: intraindividual comparison of 300 mg/ml versus 400 mg/ml iodinated contrast medium.
    Academic radiology, 2009, Volume: 16, Issue:2

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Dose-Response Relationship, Drug; Female; Humans; Io

2009
[Septal delineation using a 20 % diluted contrast chaser bolus in coronary CT angiography: a comparison of 64-slice and dual source CT].
    RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 2009, Volume: 181, Issue:4

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Coronary Angiography; Female; Heart Septum; Humans;

2009
CT-guided biopsies of pancreatic lesions: impact of contrast application prior to versus following needle placement.
    Academic radiology, 2009, Volume: 16, Issue:11

    Topics: Biopsy, Needle; Contrast Media; Female; Humans; Injections, Intravenous; Iopamidol; Male; Middle Age

2009
64-Slice CT angiography of the abdominal aorta and abdominal arteries: comparison of the diagnostic efficacy of iobitridol 350 mgI/ml versus iomeprol 400 mgI/ml in a prospective, randomised, double-blind multi-centre trial.
    European radiology, 2010, Volume: 20, Issue:3

    Topics: Aged; Angiography; Aorta, Abdominal; Contrast Media; Dose-Response Relationship, Drug; Double-Blind

2010
Reduction of contrast material volume in 3D angiography of the brain using MDCT.
    AJR. American journal of roentgenology, 2010, Volume: 195, Issue:2

    Topics: Cerebral Angiography; Contrast Media; Dose-Response Relationship, Drug; Female; Humans; Intracranial

2010
Optimization of contrast material delivery for dual-energy computed tomography pulmonary angiography in patients with suspected pulmonary embolism.
    Investigative radiology, 2012, Volume: 47, Issue:1

    Topics: Angiography; Contrast Media; Female; Humans; Iopamidol; Male; Middle Aged; Pulmonary Artery; Pulmona

2012
Optimal iodine dose for 3-dimensional multidetector-row CT angiography of the liver.
    European journal of radiology, 2012, Volume: 81, Issue:9

    Topics: Contrast Media; Dose-Response Relationship, Drug; Female; Hepatic Veins; Humans; Imaging, Three-Dime

2012
Comparison of neuroendocrine tumor detection and characterization using DOTATOC-PET in correlation with contrast enhanced CT and delayed contrast enhanced MRI.
    European journal of radiology, 2012, Volume: 81, Issue:10

    Topics: Contrast Media; Female; Gadolinium DTPA; Humans; Indium Radioisotopes; Iopamidol; Magnetic Resonance

2012
Interobserver agreement for the detection of atherosclerotic plaque in coronary CT angiography: comparison of two low-dose image acquisition protocols with standard retrospectively ECG-gated reconstruction.
    European radiology, 2012, Volume: 22, Issue:7

    Topics: Cardiac-Gated Imaging Techniques; Contrast Media; Coronary Angiography; Coronary Artery Disease; Fem

2012
C-arm CT during hepatic arteriography tumour-to-liver contrast: intraindividual comparison of three different contrast media application protocols.
    European radiology, 2013, Volume: 23, Issue:4

    Topics: Angiography; Contrast Media; Female; Humans; Iopamidol; Liver Neoplasms; Male; Middle Aged; Reproduc

2013
Quantitative therapy response assessment by volumetric iodine-uptake measurement: initial experience in patients with advanced hepatocellular carcinoma treated with sorafenib.
    European journal of radiology, 2013, Volume: 82, Issue:2

    Topics: Aged; Aged, 80 and over; Antineoplastic Agents; Carcinoma, Hepatocellular; Contrast Media; Female; H

2013
Can neutrophil gelatinase-associated lipocalin help depict early contrast material-induced nephropathy?
    Radiology, 2013, Volume: 267, Issue:1

    Topics: Acetylcysteine; Adult; Aged; Aged, 80 and over; Chi-Square Distribution; Contrast Media; Creatinine;

2013
Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with dilated cardiomyopathy.
    Journal of the American College of Cardiology, 2007, May-22, Volume: 49, Issue:20

    Topics: Artifacts; Cardiomyopathy, Dilated; Contrast Media; Coronary Angiography; Coronary Artery Disease; C

2007
MDCT angiography for detection of pulmonary emboli: comparison between equi-iodine doses of iomeprol 400 mgI/mL and iodixanol 320 mgI/mL.
    European journal of radiology, 2009, Volume: 70, Issue:3

    Topics: Aged; Angiography; Contrast Media; Dose-Response Relationship, Drug; Female; Humans; Iopamidol; Male

2009
Using thoracic helical CT to assess iodine concentration in a small volume of nonionic contrast medium during vascular opacification: a prospective study.
    AJR. American journal of roentgenology, 2000, Volume: 174, Issue:3

    Topics: Adult; Aged; Angiography; Contrast Media; Dose-Response Relationship, Drug; Female; Humans; Iodine;

2000

Other Studies

122 other studies available for iomeprol and Sensitivity and Specificity

ArticleYear
Split-bolus vs. multiphasic contrast bolus protocol in patients with pancreatic cancer or cholangiocarcinoma.
    European journal of radiology, 2019, Volume: 119

    Topics: Aged; Bile Duct Neoplasms; Bile Ducts; Carcinoma, Pancreatic Ductal; Cholangiocarcinoma; Clinical Pr

2019
Do we really need the arterial phase on CT in pelvic trauma patients?
    Emergency radiology, 2021, Volume: 28, Issue:1

    Topics: Adolescent; Adult; Aged; Aged, 80 and over; Computed Tomography Angiography; Contrast Media; Female;

2021
Value of Flat-detector Computed Tomography Angiography with Intravenous Contrast Media Injection in the Evaluation and Treatment of Acutely Ruptured Aneurysms of the AcomA complex: A Single Center Experience in 15 Cases.
    Clinical neuroradiology, 2018, Volume: 28, Issue:4

    Topics: Acute Disease; Aged; Aneurysm, Ruptured; Angiography, Digital Subtraction; Computed Tomography Angio

2018
Iodine and Fat Quantification for Differentiation of Adrenal Gland Adenomas From Metastases Using Third-Generation Dual-Source Dual-Energy Computed Tomography.
    Investigative radiology, 2018, Volume: 53, Issue:3

    Topics: Adenoma; Adrenal Gland Neoplasms; Adrenal Glands; Aged; Aged, 80 and over; Contrast Media; Diagnosis

2018
Feasibility of a Single Contrast Bolus High-Pitch Pulmonary CT Angiography Protocol Followed by Low-Dose Retrospectively ECG-Gated Cardiac CT in Patients with Suspected Pulmonary Embolism.
    RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 2018, Volume: 190, Issue:6

    Topics: Adult; Aged; Aged, 80 and over; Cardiac-Gated Imaging Techniques; Computed Tomography Angiography; C

2018
Modified National Comprehensive Cancer Network Criteria for Assessing Resectability of Pancreatic Ductal Adenocarcinoma.
    AJR. American journal of roentgenology, 2018, Volume: 210, Issue:6

    Topics: Adenocarcinoma; Aged; Aged, 80 and over; Carcinoma, Pancreatic Ductal; Chemoradiotherapy; Contrast M

2018
Correlation of Circulating miR-765, miR-93-5p, and miR-433-3p to Obstructive Coronary Heart Disease Evaluated by Cardiac Computed Tomography.
    The American journal of cardiology, 2019, 07-15, Volume: 124, Issue:2

    Topics: Aged; Biomarkers; Cardiac-Gated Imaging Techniques; Contrast Media; Coronary Disease; Female; Humans

2019
Evaluation of the value of abdominopelvic acquisition without contrast injection when performing a whole body CT scan in a patient who may have multiple trauma.
    Diagnostic and interventional imaging, 2013, Volume: 94, Issue:4

    Topics: Abdominal Injuries; Adult; Contrast Media; Female; Hemoperitoneum; Hemorrhage; Humans; Image Enhance

2013
Coronary artery abnormalities in Kawasaki disease: comparison between CT and MR coronary angiography.
    Acta radiologica (Stockholm, Sweden : 1987), 2013, Mar-01, Volume: 54, Issue:2

    Topics: Adolescent; Cardiac-Gated Imaging Techniques; Child; Child, Preschool; Contrast Media; Coronary Aneu

2013
Impact of contrast-enhanced computed tomography colonography on laparoscopic surgical planning of colorectal cancer.
    Abdominal imaging, 2013, Volume: 38, Issue:5

    Topics: Adult; Aged; Aged, 80 and over; Colonography, Computed Tomographic; Colonoscopy; Colorectal Neoplasm

2013
Invited editorial: Response to therapy assessment of colorectal liver metastasis.
    European journal of radiology, 2013, Volume: 82, Issue:6

    Topics: Adult; Aged; Colorectal Neoplasms; Contrast Media; Female; Fluorodeoxyglucose F18; Humans; Image Enh

2013
Dynamic CT angiography after abdominal aortic endovascular aneurysm repair: influence of enhancement patterns and optimal bolus timing on endoleak detection.
    Radiology, 2013, Volume: 268, Issue:3

    Topics: Aged; Aged, 80 and over; Angiography; Aortic Aneurysm, Abdominal; Contrast Media; Endoleak; Female;

2013
Myocardium: dynamic versus single-shot CT perfusion imaging.
    Radiology, 2013, Volume: 269, Issue:2

    Topics: Aged; Comorbidity; Contrast Media; Coronary Angiography; Coronary Stenosis; Exercise Test; Female; F

2013
Predictive value of zero calcium score and low-end percentiles for the presence of significant coronary artery stenosis in stable patients with suspected coronary artery disease.
    RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 2013, Volume: 185, Issue:8

    Topics: Aged; Aged, 80 and over; Body Mass Index; Calcinosis; Cardiac Catheterization; Cardiac-Gated Imaging

2013
Diagnostic accuracy of late iodine-enhancement dual-energy computed tomography for the detection of chronic myocardial infarction compared with late gadolinium-enhancement 3-T magnetic resonance imaging.
    Investigative radiology, 2013, Volume: 48, Issue:12

    Topics: Aged; Algorithms; Chronic Disease; Contrast Media; Female; Humans; Image Enhancement; Image Interpre

2013
Texture-based classification of different gastric tumors at contrast-enhanced CT.
    European journal of radiology, 2013, Volume: 82, Issue:10

    Topics: Adult; Aged; Aged, 80 and over; Algorithms; Diagnosis, Differential; Female; Humans; Imaging, Three-

2013
A comparative analysis of water-soluble and blood-pool contrast agents for in vivo vascular imaging with micro-CT.
    Academic radiology, 2013, Volume: 20, Issue:10

    Topics: Angiography; Animals; Contrast Media; Female; Iopamidol; Metal Nanoparticles; Mice; Mice, Inbred C57

2013
Increased unenhanced bowel-wall attenuation at multidetector CT is highly specific of ischemia complicating small-bowel obstruction.
    Radiology, 2014, Volume: 270, Issue:1

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Female; Humans; Intestinal Obstruction; Intestine, S

2014
Diagnostic role of coronary calcium scoring in the rapid access chest pain clinic: prospective evaluation of NICE guidance.
    European heart journal. Cardiovascular Imaging, 2014, Volume: 15, Issue:8

    Topics: Algorithms; Calcinosis; Chest Pain; Contrast Media; Coronary Angiography; Coronary Artery Disease; E

2014
Diagnostic performance of algorithm for computer-assisted detection of significant coronary artery disease in patients with acute chest pain: comparison with invasive coronary angiography.
    AJR. American journal of roentgenology, 2014, Volume: 202, Issue:4

    Topics: Acute Disease; Algorithms; Chest Pain; Contrast Media; Coronary Angiography; Coronary Artery Disease

2014
Noninvasive evaluation of coronary collateral arterial flow by coronary computed tomographic angiography.
    Circulation. Cardiovascular imaging, 2014, Volume: 7, Issue:3

    Topics: Collateral Circulation; Contrast Media; Coronary Angiography; Coronary Circulation; Coronary Vessels

2014
Split-bolus single-phase cardiac multidetector computed tomography for reliable detection of left atrial thrombus: comparison to transesophageal echocardiography.
    RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 2014, Volume: 186, Issue:11

    Topics: Aged; Atrial Fibrillation; Catheter Ablation; Contrast Media; Echocardiography, Transesophageal; Fem

2014
Assessment of the hepatic veins in poor contrast conditions using dual energy CT: evaluation of a novel monoenergetic extrapolation software algorithm.
    RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 2014, Volume: 186, Issue:6

    Topics: Adult; Aged; Aged, 80 and over; Algorithms; Contrast Media; Female; Hepatic Veins; Humans; Image Enh

2014
Selective intra-arterial dual-energy CT angiography (s-CTA) in lower extremity arterial occlusive disease.
    European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery, 2014, Volume: 48, Issue:3

    Topics: Aged; Aged, 80 and over; Angiography; Angiography, Digital Subtraction; Arterial Occlusive Diseases;

2014
Volume perfusion CT (VPCT) for the differential diagnosis of patients with suspected cerebral vasospasm: qualitative and quantitative analysis of 3D parameter maps.
    European journal of radiology, 2014, Volume: 83, Issue:10

    Topics: Adult; Aged; Aged, 80 and over; Cerebral Angiography; Contrast Media; Diagnosis, Differential; Femal

2014
Evaluation of a high iodine delivery rate in combination with low tube current for dose reduction in pulmonary computed tomography angiography.
    Journal of thoracic imaging, 2014, Volume: 29, Issue:5

    Topics: Aged; Contrast Media; Female; Humans; Image Processing, Computer-Assisted; Iodine; Iopamidol; Male;

2014
Identification of predictive CT angiographic factors in the development of high-risk type 2 endoleaks after endovascular aneurysm repair in patients with infrarenal aortic aneurysms.
    RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 2015, Volume: 187, Issue:1

    Topics: Aged; Aged, 80 and over; Aortic Aneurysm, Abdominal; Aortography; Blood Vessel Prosthesis Implantati

2015
CT angiography in non-traumatic subarachnoid hemorrhage: the importance of arterial attenuation for the detection of intracranial aneurysms.
    Acta radiologica (Stockholm, Sweden : 1987), 2015, Volume: 56, Issue:10

    Topics: Adolescent; Adult; Aged; Aged, 80 and over; Aneurysm, Ruptured; Angiography, Digital Subtraction; Ce

2015
Effects of guided random sampling of TCCs on blood flow values in CT perfusion studies of lung tumors.
    Academic radiology, 2015, Volume: 22, Issue:1

    Topics: Adult; Aged; Aged, 80 and over; Angiography; Artifacts; Blood Flow Velocity; Computer Simulation; Co

2015
Feasibility of Selective Catheter-Directed Coronary Computed Tomography Angiography Using Ultralow-Dose Intracoronary Contrast Injection in a Swine Model.
    Investigative radiology, 2015, Volume: 50, Issue:7

    Topics: Animals; Cardiac Catheterization; Contrast Media; Coronary Angiography; Dose-Response Relationship,

2015
Value of the "spine sign" on lateral chest views.
    The British journal of radiology, 2015, Volume: 88, Issue:1050

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Female; Humans; Iopamidol; Male; Middle Aged; Predic

2015
Contrast enhanced chest-MDCT in oncologic patients. Prospective evaluation of the prevalence of incidental pulmonary embolism and added value of thin reconstructions.
    European radiology, 2015, Volume: 25, Issue:11

    Topics: Adult; Aged; Aged, 80 and over; Colonic Neoplasms; Contrast Media; False Negative Reactions; False P

2015
Evaluation of image quality, radiation dose and diagnostic performance of dual-energy CT datasets in patients with hepatocellular carcinoma.
    Clinical radiology, 2015, Volume: 70, Issue:9

    Topics: Adult; Aged; Aged, 80 and over; Carcinoma, Hepatocellular; Contrast Media; Female; Humans; Imaging,

2015
Improved Image Quality in Head and Neck CT Using a 3D Iterative Approach to Reduce Metal Artifact.
    AJNR. American journal of neuroradiology, 2015, Volume: 36, Issue:10

    Topics: Adult; Aged; Aged, 80 and over; Algorithms; Artifacts; Contrast Media; Dental Restoration, Permanent

2015
[Portal vein aneurysm - a rare incidental finding].
    RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 2016, Volume: 188, Issue:2

    Topics: Aged; Aneurysm; Arteriovenous Fistula; Contrast Media; Diagnosis, Differential; Humans; Hypertension

2016
Diagnostic Performance of Transluminal Attenuation Gradient and Noninvasive Fractional Flow Reserve Derived from 320-Detector Row CT Angiography to Diagnose Hemodynamically Significant Coronary Stenosis: An NXT Substudy.
    Radiology, 2016, Volume: 279, Issue:1

    Topics: Blood Flow Velocity; Cardiac-Gated Imaging Techniques; Contrast Media; Coronary Angiography; Coronar

2016
Diagnostic Performance and Patient Acceptance of Reduced-Laxative CT Colonography for the Detection of Polypoid and Non-Polypoid Neoplasms: A Multicenter Prospective Trial.
    Radiology, 2017, Volume: 282, Issue:2

    Topics: Aged; Cathartics; Colonic Polyps; Colonography, Computed Tomographic; Colorectal Neoplasms; Contrast

2017
Coronary artery aneurysms detected by computed tomography coronary angiography.
    European heart journal. Cardiovascular Imaging, 2017, Nov-01, Volume: 18, Issue:11

    Topics: Computed Tomography Angiography; Contrast Media; Coronary Aneurysm; Female; Humans; Incidental Findi

2017
Highly iodinated intravenous contrast material for PET/CT - a feasibility study.
    RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 2008, Volume: 180, Issue:8

    Topics: Adolescent; Adult; Aged; Artifacts; Dose-Response Relationship, Drug; Feasibility Studies; Female; H

2008
Which Iodine concentration in chest CT?--a prospective study in 300 patients.
    European radiology, 2008, Volume: 18, Issue:12

    Topics: Contrast Media; Dose-Response Relationship, Drug; Female; Humans; Iohexol; Iopamidol; Male; Middle A

2008
Clinical utility of dual-energy CT in the evaluation of solitary pulmonary nodules: initial experience.
    Radiology, 2008, Volume: 249, Issue:2

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Female; Humans; Iopamidol; Male; Middle Aged; Radiat

2008
Efficacy of computer aided analysis in detection of significant coronary artery stenosis in cardiac using dual source computed tomography.
    The international journal of cardiovascular imaging, 2009, Volume: 25, Issue:2

    Topics: Aged; Contrast Media; Coronary Angiography; Coronary Stenosis; Female; Humans; Imaging, Three-Dimens

2009
Routine use of positive oral contrast material is not required for oncology patients undergoing follow-up multidetector CT.
    Radiology, 2009, Volume: 250, Issue:1

    Topics: Administration, Oral; Adult; Aged; Aged, 80 and over; Barium Sulfate; Contrast Media; Digestive Syst

2009
Mapping the zonal organization of tumor perfusion and permeability in a rat glioma model by using dynamic contrast-enhanced synchrotron radiation CT.
    Radiology, 2009, Volume: 250, Issue:3

    Topics: Animals; Brain Neoplasms; Contrast Media; Disease Models, Animal; Glioma; Iopamidol; Male; Neovascul

2009
[Are oral contrast media required for follow-up assessments?].
    Der Radiologe, 2009, Volume: 49, Issue:4

    Topics: Administration, Oral; Adult; Aged; Aged, 80 and over; Barium Sulfate; Contrast Media; Digestive Syst

2009
In-vivo measurements of coronary blood flow using 16-slice multidetector spiral computed tomography (MDCT) in a porcine model.
    RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 2009, Volume: 181, Issue:3

    Topics: Animals; Blood Flow Velocity; Blood Volume; Contrast Media; Coronary Angiography; Coronary Circulati

2009
[Refined staging in Hilar bronchial neoplasms with ECG-gated multislice-CT---case report].
    Rontgenpraxis; Zeitschrift fur radiologische Technik, 2008, Volume: 56, Issue:5

    Topics: Aged; Bronchi; Carcinoma, Bronchogenic; Carcinoma, Small Cell; Carcinoma, Squamous Cell; Cardiac-Gat

2008
Stenosis detection in native hemodialysis fistulas with MDCT angiography.
    AJR. American journal of roentgenology, 2009, Volume: 192, Issue:4

    Topics: Adult; Aged; Aged, 80 and over; Angiography; Angiography, Digital Subtraction; Arteriovenous Shunt,

2009
64-Section multi-detector row CT in the preoperative diagnosis of peritoneal carcinomatosis: correlation with histopathological findings.
    Abdominal imaging, 2010, Volume: 35, Issue:6

    Topics: Adult; Aged; Carcinoma; Contrast Media; Diatrizoate Meglumine; Female; Humans; Iopamidol; Male; Midd

2010
Tracer kinetics analysis of dynamic contrast-enhanced CT and MR data in patients with squamous cell carcinoma of the upper aerodigestive tract: comparison of the results.
    Clinical physiology and functional imaging, 2009, Volume: 29, Issue:5

    Topics: Algorithms; Carcinoma, Squamous Cell; Computer Simulation; Contrast Media; Female; Gadolinium DTPA;

2009
Diagnostic accuracy of MDCT coronary angiography in patients referred for heart valve surgery.
    La Radiologia medica, 2009, Volume: 114, Issue:5

    Topics: Aged; Contrast Media; Coronary Angiography; Coronary Disease; Female; Heart Valve Diseases; Humans;

2009
Automatic bone and plaque removal using dual energy CT for head and neck angiography: feasibility and initial performance evaluation.
    European journal of radiology, 2010, Volume: 76, Issue:1

    Topics: Angiography, Digital Subtraction; Artifacts; Bone and Bones; Carotid Stenosis; Contrast Media; Feasi

2010
[Image quality of CT angiography of coronary arteries depending on the degree of coronary calcification using a dual source CT scanner].
    RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 2009, Volume: 181, Issue:9

    Topics: Aged; Angiography, Digital Subtraction; Artifacts; Calcinosis; Cardiac Catheterization; Contrast Med

2009
In vivo imaging of MSCT and micro-CT: a comparison.
    RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 2010, Volume: 182, Issue:4

    Topics: Animals; Basal Ganglia; Basal Ganglia Diseases; Brain Neoplasms; Cell Line, Tumor; Contrast Media; G

2010
Whole-body magnetic resonance angiography with additional steady-state acquisition of the infragenicular arteries in patients with peripheral arterial disease.
    Cardiovascular and interventional radiology, 2010, Volume: 33, Issue:3

    Topics: Aged; Angiography, Digital Subtraction; Contrast Media; Female; Gadolinium; Humans; Image Interpreta

2010
Role of 64-slice cardiac computed tomography in the evaluation of patients with non-ST-elevation acute coronary syndrome.
    La Radiologia medica, 2010, Volume: 115, Issue:3

    Topics: Acute Coronary Syndrome; Aged; Analysis of Variance; Chi-Square Distribution; Contrast Media; Corona

2010
Impact of contrast material volume on quantitative assessment of reperfused acute myocardial infarction using delayed-enhancement 64-slice CT: experience in a porcine model.
    La Radiologia medica, 2010, Volume: 115, Issue:1

    Topics: Animals; Contrast Media; Disease Models, Animal; Iopamidol; Myocardial Infarction; Myocardial Reperf

2010
Preoperative evaluation in aortic endocarditis: findings on cardiac CT.
    AJR. American journal of roentgenology, 2010, Volume: 194, Issue:3

    Topics: Aorta, Thoracic; Aortic Diseases; Contrast Media; Electrocardiography; Endocarditis; Feasibility Stu

2010
Suitability of semi-automated tumor response assessment of liver metastases using a dedicated software package.
    RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 2010, Volume: 182, Issue:7

    Topics: Adult; Aged; Antineoplastic Agents; Artificial Intelligence; Colorectal Neoplasms; Contrast Media; D

2010
Comparison of diffusion-weighted MR imaging and multidetector-row CT in the detection of liver metastases in patients operated for pancreatic cancer.
    Abdominal imaging, 2011, Volume: 36, Issue:2

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Diffusion Magnetic Resonance Imaging; Female; Humans

2011
Dual-energy CT angiography of the lungs: comparison of test bolus and bolus tracking techniques for the determination of scan delay.
    European journal of radiology, 2012, Volume: 81, Issue:1

    Topics: Algorithms; Computer Simulation; Contrast Media; Female; Humans; Iopamidol; Lung; Male; Metabolic Cl

2012
Dual energy CT (DECT) of the liver: conventional versus virtual unenhanced images.
    European radiology, 2010, Volume: 20, Issue:12

    Topics: Contrast Media; Humans; Iopamidol; Liver; Liver Neoplasms; Middle Aged; Radiation Dosage; Radiation

2010
Dual-energy CT for the assessment of chronic myocardial infarction in patients with chronic coronary artery disease: comparison with 3-T MRI.
    AJR. American journal of roentgenology, 2010, Volume: 195, Issue:3

    Topics: Adult; Aged; Artifacts; Chronic Disease; Contrast Media; Coronary Angiography; Coronary Artery Bypas

2010
Computer-based automated left atrium segmentation and volumetry from ECG-gated coronary CT angiography data: comparison with manual slice segmentation and ultrasound planimetric methods.
    RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 2010, Volume: 182, Issue:12

    Topics: Aged; Angiography; Cardiac-Gated Imaging Techniques; Contrast Media; Coronary Angiography; Diastole;

2010
Inflammatory bowel disease: value in diagnosis and management of MDCT-enteroclysis and 99mTc-HMPAO labeled leukocyte scintigraphy.
    Abdominal imaging, 2011, Volume: 36, Issue:4

    Topics: Adult; Biopsy; Chi-Square Distribution; Contrast Media; Female; Humans; Inflammatory Bowel Diseases;

2011
Ischemic stroke: etiologic work-up with multidetector CT of heart and extra- and intracranial arteries.
    Radiology, 2011, Volume: 258, Issue:1

    Topics: Adult; Aged; Aged, 80 and over; Brain Ischemia; Cerebral Arteries; Cerebrovascular Circulation; Cont

2011
Assessment of Agatston coronary artery calcium score using contrast-enhanced CT coronary angiography.
    AJR. American journal of roentgenology, 2010, Volume: 195, Issue:6

    Topics: Calcinosis; Contrast Media; Coronary Angiography; Coronary Stenosis; Electrocardiography; Female; Hu

2010
Carotid artery stenosis at MSCT: is there a threshold in millimeters that determines clinical significance?
    Cardiovascular and interventional radiology, 2012, Volume: 35, Issue:1

    Topics: Adult; Aged; Aged, 80 and over; Carotid Stenosis; Contrast Media; Female; Humans; Iopamidol; Logisti

2012
Application of a new pulmonary artery obstruction score in the prognostic evaluation of acute pulmonary embolism: comparison with clinical and haemodynamic parameters.
    La Radiologia medica, 2011, Volume: 116, Issue:2

    Topics: Acute Disease; Adult; Aged; Aged, 80 and over; Angiography; Chi-Square Distribution; Contrast Media;

2011
High diagnostic accuracy of prospective ECG-gating 64-slice computed tomography coronary angiography for the detection of in-stent restenosis: in-stent restenosis assessment by low-dose MDCT.
    European radiology, 2011, Volume: 21, Issue:7

    Topics: Chi-Square Distribution; Contrast Media; Coronary Angiography; Coronary Restenosis; Electrocardiogra

2011
Gadobenate dimeglumine-enhanced 3.0-T MR imaging versus multiphasic 64-detector row CT: prospective evaluation in patients suspected of having pancreatic cancer.
    Radiology, 2011, Volume: 259, Issue:3

    Topics: Aged; Aged, 80 and over; Contrast Media; Diagnosis, Differential; Female; Humans; Iopamidol; Logisti

2011
Impact of tube current-time and tube voltage reduction in 64-detector-row computed tomography pulmonary angiography for pulmonary embolism in a porcine model.
    Journal of thoracic imaging, 2012, Volume: 27, Issue:2

    Topics: Angiography; Animals; Contrast Media; Disease Models, Animal; Iopamidol; Predictive Value of Tests;

2012
Should the dose of contrast medium be determined solely on the basis of body weight regardless of the patient's sex?
    Japanese journal of radiology, 2011, Volume: 29, Issue:5

    Topics: Adolescent; Adult; Aged; Aged, 80 and over; Aorta; Body Weight; Contrast Media; Dose-Response Relati

2011
Evaluation of computer-assisted quantification of carotid artery stenosis.
    Journal of digital imaging, 2012, Volume: 25, Issue:2

    Topics: Angiography; Carotid Stenosis; Contrast Media; Humans; Imaging, Three-Dimensional; Iopamidol; Radiog

2012
Assessment of mitral valve stenosis by helical MDCT: comparison with transthoracic doppler echocardiography and cardiac catheterization.
    AJR. American journal of roentgenology, 2011, Volume: 197, Issue:3

    Topics: Aged; Aged, 80 and over; Cardiac Catheterization; Cardiac-Gated Imaging Techniques; Contrast Media;

2011
Contrast-enhanced dual-energy CT of gastrointestinal stromal tumors: is iodine-related attenuation a potential indicator of tumor response?
    Investigative radiology, 2012, Volume: 47, Issue:1

    Topics: Adult; Aged; Contrast Media; Female; Gastrointestinal Stromal Tumors; Humans; Iopamidol; Male; Middl

2012
Single-centre prospective comparison between contrast-enhanced ultrasound and computed tomography angiography after EVAR.
    European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery, 2011, Volume: 42, Issue:6

    Topics: Angioplasty; Aortic Aneurysm, Abdominal; Aortography; Blood Vessel Prosthesis Implantation; Contrast

2011
Peripheral arterial occlusive disease: diagnostic performance and effect on therapeutic management of 64-section CT angiography.
    Radiology, 2011, Volume: 261, Issue:3

    Topics: Aged; Angiography; Angiography, Digital Subtraction; Arterial Occlusive Diseases; Chi-Square Distrib

2011
Diagnostic accuracy of second-generation dual-source computed tomography coronary angiography with iterative reconstructions: a real-world experience.
    La Radiologia medica, 2012, Volume: 117, Issue:5

    Topics: Algorithms; Contrast Media; Coronary Angiography; Coronary Stenosis; Female; Humans; Iopamidol; Like

2012
Diagnostic accuracy of C-arm CT during selective transcatheter angiography for hepatocellular carcinoma: comparison with intravenous contrast-enhanced, biphasic, dynamic MDCT.
    European radiology, 2012, Volume: 22, Issue:4

    Topics: Aged; Aged, 80 and over; Angiography; Carcinoma, Hepatocellular; Catheterization; Contrast Media; Eq

2012
Angiographic CT with intravenous contrast injection compared with conventional rotational angiography in the diagnostic work-up of cerebral aneurysms.
    AJNR. American journal of neuroradiology, 2012, Volume: 33, Issue:5

    Topics: Adult; Aged; Cerebral Angiography; Contrast Media; Female; Humans; Injections, Intravenous; Intracra

2012
Preoperative local staging of colosigmoideal cancer: air versus water multidetector-row CT colonography.
    La Radiologia medica, 2012, Volume: 117, Issue:2

    Topics: Adult; Aged; Air; Colonic Neoplasms; Colonography, Computed Tomographic; Contrast Media; Female; Hum

2012
Contrast timing in computed tomography: effect of different contrast media concentrations on bolus geometry.
    European journal of radiology, 2012, Volume: 81, Issue:4

    Topics: Animals; Aortography; Contrast Media; Dogs; Dose-Response Relationship, Drug; Female; Iohexol; Iopam

2012
Perineural spread of adenoid cystic carcinoma in the oral and maxillofacial regions: evaluation with contrast-enhanced CT and MRI.
    Dento maxillo facial radiology, 2012, Volume: 41, Issue:2

    Topics: Adult; Aged; Carcinoma, Adenoid Cystic; Contrast Media; Facial Neoplasms; Female; Humans; Iopamidol;

2012
Pediatric nonlymphoblastic non-Hodgkin lymphoma: baseline, interim, and posttreatment PET/CT versus contrast-enhanced CT for evaluation--a prospective study.
    Radiology, 2012, Volume: 262, Issue:3

    Topics: Adolescent; Antineoplastic Combined Chemotherapy Protocols; Child; Child, Preschool; Contrast Media;

2012
Time-resolved CT angiography for the detection and classification of endoleaks.
    Radiology, 2012, Volume: 263, Issue:3

    Topics: Aged; Angiography; Aortic Aneurysm; Contrast Media; Endoleak; Endovascular Procedures; Feasibility S

2012
Nontraumatic subarachnoid hemorrhage management: evaluation with reduced iodine volume at CT angiography.
    Radiology, 2012, Volume: 264, Issue:1

    Topics: Adult; Aged; Aged, 80 and over; Cerebral Angiography; Contrast Media; Female; Humans; Imaging, Three

2012
A method for improving iodine contrast enhancement in abdominal computed tomography: experimental study in a pig model.
    European radiology, 2013, Volume: 23, Issue:4

    Topics: Animals; Contrast Media; Dose-Response Relationship, Drug; Iopamidol; Radiographic Image Enhancement

2013
Comparison of iodinated contrast media for the assessment of atherosclerotic plaque attenuation values by CT coronary angiography: observations in an ex vivo model.
    The British journal of radiology, 2013, Volume: 86, Issue:1021

    Topics: Contrast Media; Coronary Angiography; Coronary Artery Disease; Dose-Response Relationship, Drug; Fem

2013
Acute cholecystitis: quantitative and qualitative evaluation with 64-section helical CT.
    Acta radiologica (Stockholm, Sweden : 1987), 2013, Volume: 54, Issue:5

    Topics: Adult; Aged; Aged, 80 and over; Case-Control Studies; Cholecystitis, Acute; Contrast Media; Female;

2013
Solitary pulmonary nodules: dynamic enhanced multi-detector row CT study and comparison with vascular endothelial growth factor and microvessel density.
    Radiology, 2004, Volume: 233, Issue:1

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Female; Follow-Up Studies; Humans; Image Processing,

2004
Solitary pulmonary nodules: dynamic enhanced multi-detector row CT study and comparison with vascular endothelial growth factor and microvessel density.
    Radiology, 2004, Volume: 233, Issue:1

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Female; Follow-Up Studies; Humans; Image Processing,

2004
Solitary pulmonary nodules: dynamic enhanced multi-detector row CT study and comparison with vascular endothelial growth factor and microvessel density.
    Radiology, 2004, Volume: 233, Issue:1

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Female; Follow-Up Studies; Humans; Image Processing,

2004
Solitary pulmonary nodules: dynamic enhanced multi-detector row CT study and comparison with vascular endothelial growth factor and microvessel density.
    Radiology, 2004, Volume: 233, Issue:1

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Female; Follow-Up Studies; Humans; Image Processing,

2004
Image assessment with multislice CT coronary angiography.
    La Radiologia medica, 2005, Volume: 109, Issue:3

    Topics: Contrast Media; Coronary Angiography; Coronary Artery Disease; Coronary Stenosis; Female; Humans; Im

2005
3D CT protocol in the assessment of the esophageal neoplastic lesions: can it improve TNM staging?
    European radiology, 2006, Volume: 16, Issue:2

    Topics: Adenocarcinoma; Adult; Aged; Carcinoma, Squamous Cell; Contrast Media; Esophageal Neoplasms; Esophag

2006
Solitary pulmonary nodule: characterization with combined wash-in and washout features at dynamic multi-detector row CT.
    Radiology, 2005, Volume: 237, Issue:2

    Topics: Adult; Aged; Aged, 80 and over; Chi-Square Distribution; Contrast Media; Diagnosis, Differential; Fe

2005
Improving diagnostic accuracy of MDCT coronary angiography in patients with mild heart rhythm irregularities using ECG editing.
    AJR. American journal of roentgenology, 2006, Volume: 186, Issue:3

    Topics: Atrial Fibrillation; Bradycardia; Cardiac Complexes, Premature; Contrast Media; Coronary Angiography

2006
Multidetector CT with double arterial phase and high-iodine-concentration contrast agent in the detection of hepatocellular carcinoma.
    La Radiologia medica, 2006, Volume: 111, Issue:2

    Topics: Adult; Aged; Aged, 80 and over; Carcinoma, Hepatocellular; Contrast Media; Female; Follow-Up Studies

2006
Acute pulmonary embolism to the subsegmental level: diagnostic accuracy of three MRI techniques compared with 16-MDCT.
    AJR. American journal of roentgenology, 2006, Volume: 187, Issue:1

    Topics: Acute Disease; Contrast Media; Female; Humans; Iopamidol; Lung; Magnetic Resonance Angiography; Magn

2006
Multidetector CT in abdominal aortic aneurysm treated with endovascular repair: are unenhanced and delayed phase enhanced images effective for endoleak detection?
    Radiology, 2006, Volume: 241, Issue:3

    Topics: Aged; Aged, 80 and over; Aortic Aneurysm, Abdominal; Blood Vessel Prosthesis Implantation; Contrast

2006
Possible small-bowel neoplasms: contrast-enhanced and water-enhanced multidetector CT enteroclysis.
    Radiology, 2006, Volume: 241, Issue:3

    Topics: Adolescent; Adult; Aged; Aged, 80 and over; Contrast Media; Diagnosis, Differential; Endoscopy, Gast

2006
The benefit of 64-MDCT prior to invasive coronary angiography in symptomatic post-CABG patients.
    The international journal of cardiovascular imaging, 2007, Volume: 23, Issue:3

    Topics: Aged; Contrast Media; Coronary Angiography; Coronary Artery Bypass; Coronary Disease; Coronary Reste

2007
Influence of convolution filtering on coronary plaque attenuation values: observations in an ex vivo model of multislice computed tomography coronary angiography.
    European radiology, 2007, Volume: 17, Issue:7

    Topics: Aged; Contrast Media; Coronary Angiography; Coronary Artery Disease; Female; Humans; Image Enhanceme

2007
Clinical evaluation of a computer-aided diagnosis (CAD) prototype for the detection of pulmonary embolism.
    Academic radiology, 2007, Volume: 14, Issue:6

    Topics: Algorithms; Artificial Intelligence; Contrast Media; Diagnosis, Computer-Assisted; False Positive Re

2007
Initial Experience with a Novel Low-Dose Micro-CT System.
    RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 2007, Volume: 179, Issue:7

    Topics: Animals; Coated Materials, Biocompatible; Contrast Media; Coronary Angiography; Coronary Restenosis;

2007
3-T MRI: usefulness for evaluating primary lung cancer and small nodules in lobes not containing primary tumors.
    AJR. American journal of roentgenology, 2007, Volume: 189, Issue:2

    Topics: Adult; Aged; Aged, 80 and over; Biopsy, Needle; Carcinoma, Non-Small-Cell Lung; Contrast Media; Fema

2007
Multidetector CT in diagnostic work-up of patients with primary hyperparathyroidism.
    La Radiologia medica, 2007, Volume: 112, Issue:5

    Topics: Contrast Media; Diagnosis, Differential; Female; Humans; Hyperparathyroidism, Primary; Iopamidol; Ma

2007
Multi-slice CT (MSCT) angiography for assessment of traumatic lesions of lower limbs peripheral arteries.
    Emergency radiology, 2007, Volume: 14, Issue:6

    Topics: Adolescent; Adult; Aged; Angiography; Angiography, Digital Subtraction; Blood Vessels; Contrast Medi

2007
Increasing contrast agent concentration improves enhancement in first-pass CT perfusion.
    AJNR. American journal of neuroradiology, 2007, Volume: 28, Issue:7

    Topics: Aged; Contrast Media; Dose-Response Relationship, Drug; Female; Humans; Image Enhancement; Iohexol;

2007
Late enhancement using multidetector row computer tomography: a feasibility study with low dose 80 kV protocol.
    European journal of radiology, 2008, Volume: 66, Issue:1

    Topics: Adult; Aged; Contrast Media; Coronary Angiography; Coronary Stenosis; Feasibility Studies; Female; G

2008
Forty-slice MDCT enteroclysis: evaluation after oral administration of isotonic solution in Crohn's disease.
    La Radiologia medica, 2007, Volume: 112, Issue:6

    Topics: Administration, Oral; Adult; Cathartics; Contrast Media; Crohn Disease; Female; Humans; Intestine, S

2007
Non-invasive evaluation of coronary artery stent patency with retrospectively ECG-gated 64-slice CT angiography.
    European radiology, 2008, Volume: 18, Issue:2

    Topics: Aged; Aged, 80 and over; Blood Vessel Prosthesis; Contrast Media; Coronary Angiography; Coronary Res

2008
Multidetector CT in abdominal aortic aneurysm following endovascular repair: how to consider the value of a delayed phase.
    Radiology, 2007, Volume: 245, Issue:2

    Topics: Aged; Aged, 80 and over; Aortic Aneurysm, Abdominal; Blood Vessel Prosthesis Implantation; Contrast

2007
Diagnostic accuracy of 64-slice computed tomography coronary angiography in patients with low-to-intermediate risk.
    La Radiologia medica, 2007, Volume: 112, Issue:7

    Topics: Algorithms; Chest Pain; Contrast Media; Coronary Angiography; Coronary Disease; Coronary Stenosis; D

2007
Imaging of myocardial infarction using a 64-slice MDCT scanner: correlation between infarcted region and status of territory-dependent coronary artery.
    La Radiologia medica, 2007, Volume: 112, Issue:8

    Topics: Adult; Aged; Aged, 80 and over; Analysis of Variance; Contrast Media; Coronary Angiography; Female;

2007
Non-traumatic acute bowel disease: differential diagnosis with 64-row MDCT.
    Emergency radiology, 2008, Volume: 15, Issue:3

    Topics: Abdomen, Acute; Adult; Aged; Aged, 80 and over; Contrast Media; Diagnosis, Differential; Female; Hum

2008
Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy.
    Radiology, 2008, Volume: 247, Issue:2

    Topics: Algorithms; Calcinosis; Contrast Media; Coronary Angiography; Coronary Stenosis; Female; Heart Rate;

2008
64-slice computed tomography coronary angiography: diagnostic accuracy in the real world.
    La Radiologia medica, 2008, Volume: 113, Issue:2

    Topics: Aged; Contrast Media; Coronary Angiography; Coronary Artery Disease; Coronary Stenosis; Female; Huma

2008
Performance of integrated FDG-PET/contrast-enhanced CT in the diagnosis of recurrent ovarian cancer: comparison with integrated FDG-PET/non-contrast-enhanced CT and enhanced CT.
    European journal of nuclear medicine and molecular imaging, 2008, Volume: 35, Issue:8

    Topics: Adult; Aged; Contrast Media; Female; Fluorodeoxyglucose F18; Humans; Iopamidol; Male; Middle Aged; N

2008
Functional CT of squamous cell carcinoma in the head and neck: repeatability of tumor and muscle quantitative measurements, inter- and intra-observer agreement.
    European radiology, 2008, Volume: 18, Issue:10

    Topics: Carcinoma, Squamous Cell; Contrast Media; Female; Head and Neck Neoplasms; Humans; Iopamidol; Male;

2008
Lung perfusion in patients with pulmonary hypertension: comparison between MDCT pulmonary angiography with minIP reconstructions and 99mTc-MAA perfusion scan.
    Investigative radiology, 2008, Volume: 43, Issue:6

    Topics: Adult; Aged; Aged, 80 and over; Angiography; Female; Humans; Hypertension, Pulmonary; Iopamidol; Mal

2008
[Conventional pelvis-leg arteriography with iomeprol 400. Does higher concentration contrast medium have a diagnostic advantage?].
    Rontgenpraxis; Zeitschrift fur radiologische Technik, 1997, Volume: 50, Issue:3

    Topics: Aged; Angiography; Contrast Media; Dose-Response Relationship, Drug; Female; Humans; Iopamidol; Isch

1997
[Multidetector CT Angiography - is it a valuable screening tool to detect significant renal artery stenosis?].
    RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 2001, Volume: 173, Issue:12

    Topics: Aged; Angiography; Angiography, Digital Subtraction; Contrast Media; Female; Humans; Image Processin

2001
Usefulness of multislice computed tomography for detecting obstructive coronary artery disease.
    The American journal of cardiology, 2002, Apr-15, Volume: 89, Issue:8

    Topics: Contrast Media; Coronary Angiography; Coronary Artery Disease; Electrocardiography; Female; Humans;

2002