iohexol has been researched along with Electrolytes in 16 studies
Iohexol: An effective non-ionic, water-soluble contrast agent which is used in myelography, arthrography, nephroangiography, arteriography, and other radiographic procedures. Its low systemic toxicity is the combined result of low chemotoxicity and low osmolality.
iohexol : A benzenedicarboxamide compound having N-(2,3-dihydroxypropyl)carbamoyl groups at the 1- and 3-positions, iodo substituents at the 2-, 4- and 6-positions and an N-(2,3-dihydroxypropyl)acetamido group at the 5-position.
Electrolytes: Substances that dissociate into two or more ions, to some extent, in water. Solutions of electrolytes thus conduct an electric current and can be decomposed by it (ELECTROLYSIS). (Grant & Hackh's Chemical Dictionary, 5th ed)
Excerpt | Relevance | Reference |
---|---|---|
"The influence of the nonionic contrast agent iohexol on blood pH and the cation electrolytes Ca, Na, K and Mg was studied in vivo in humans during the intravenous pyelography." | 7.71 | Iohexol does not influence the levels of blood serum cation electrolytes during intravenous pyelography. ( Christopoulos, S; Kaitatzis, C; Karamanos, G; Katsimba, D; Kokkas, B; Mironidou, M, 2001) |
"We investigated whether addition of a balanced electrolyte supplement and oxygen to the nonionic contrast medium iohexol reduces the risk of ventricular fibrillation (VF), and studied regional electrophysiology prior to the VF event." | 7.69 | Cardiac effects of adding electrolytes and oxygen to iohexol in a dog model of contrast media-induced ventricular fibrillation. ( Jacobsen, EA; Kløw, NE; Pedersen, HK; Refsum, H, 1995) |
"1 mM MgCl2 to iohexol on cardiac electrophysiology and hemodynamics (iohexol+electrolytes = IPE)." | 3.69 | Cardiac effects of coronary arteriography with electrolyte addition to iohexol. A study in dogs with and without heart failure. ( Jacobsen, EA; Kløw, NE; Pedersen, HK; Refsum, H, 1994) |
" Iohexol supplemented with electrolytes (iohexol + electrolytes = IPE), oxygenated IPE (IPE+O), Ringer acetate, and oxygenated Ringer acetate were injected into the left coronary artery." | 3.69 | Coronary arteriography with an oxygenated contrast medium: cardiac effects in dogs with and without acute ischemic heart failure. ( Jacobsen, EA; Pedersen, HK; Refsum, H, 1996) |
"We investigated the cardiac effects of single and repeated contrast media injections in dogs with heart failure and compared the effects of iohexol with iohexol supplemented with electrolytes (30 mmol/l NaCl, 0." | 3.69 | Additive hemodynamic and electrophysiologic effects of repeated intracoronary contrast media injections in dogs with heart failure. ( Jacobsen, EA; Mortensen, E; Pedersen, HK; Refsum, H, 1995) |
"The effect of addition of calcium, potassium and magnesium to iohexol (350 mg I/ml) enriched with 30 mM sodium was investigated with regard to ventricular fibrillation (VF) in isolated rabbit hearts." | 3.68 | Reduced risk of ventricular fibrillation by balancing sodium, calcium, potassium and magnesium added to nonionic contrast media. An investigation in the isolated rabbit heart. ( Almén, T; Bååth, L; Besjakov, J; Oksendal, AN, 1993) |
"A prospective study was done on 20 adult patients to determine changes in the serum electrolytes and proteins produced by bolus administration of 100 ml of the nonionic contrast medium iohexol (Omnipaque 300) for intravenous urography." | 3.67 | The effect of nonionic radiographic contrast medium on serum electrolytes and proteins during intravenous urography. ( Brunet, WG; Henderson, AR; Hutton, LC, 1989) |
Timeframe | Studies, this research(%) | All Research% |
---|---|---|
pre-1990 | 3 (18.75) | 18.7374 |
1990's | 9 (56.25) | 18.2507 |
2000's | 4 (25.00) | 29.6817 |
2010's | 0 (0.00) | 24.3611 |
2020's | 0 (0.00) | 2.80 |
Authors | Studies |
---|---|
Budhiraja, P | 1 |
Chen, Z | 1 |
Popovtzer, M | 1 |
Izci, C | 1 |
Ogurtan, Z | 1 |
Ceylan, C | 1 |
Chai, CM | 2 |
Karlsson, JO | 1 |
Almén, T | 3 |
Levorstad, K | 1 |
Kolbenstvedt, A | 1 |
Sommerfelt, SC | 1 |
Zachrisson, BE | 1 |
Jagenburg, R | 1 |
Egeblad, M | 1 |
Thrane Nielsen, N | 1 |
Sjöberg, S | 1 |
Oldbring, J | 1 |
Sveen, K | 1 |
Maly, P | 1 |
Fex, G | 1 |
Jynge, P | 1 |
Blankson, H | 1 |
Schjøtt, J | 1 |
Holten, T | 1 |
Oksendal, AN | 2 |
Jacobsen, EA | 4 |
Pedersen, HK | 5 |
Kløw, NE | 2 |
Refsum, H | 4 |
Besjakov, J | 2 |
Bååth, L | 2 |
Karlsen, SJ | 1 |
Smevik, B | 1 |
Berg, KJ | 1 |
Mortensen, E | 1 |
Kokkas, B | 1 |
Mironidou, M | 1 |
Katsimba, D | 1 |
Kaitatzis, C | 1 |
Karamanos, G | 1 |
Christopoulos, S | 1 |
Brunet, WG | 1 |
Hutton, LC | 1 |
Henderson, AR | 1 |
2 trials available for iohexol and Electrolytes
Article | Year |
---|---|
Effects of hyperosmolar ionic and low osmolar non-ionic contrast media on acid base, blood gas and electrolyte status in dogs.
Topics: Animals; Blood Gas Analysis; Contrast Media; Diatrizoate; Dog Diseases; Dogs; Electrolytes; Female; | 2004 |
Tolerability and diagnostic usefulness of iohexol in urography. An open multicentre clinical trial.
Topics: Adult; Aged; Blood Cell Count; Clinical Trials as Topic; Contrast Media; Electrolytes; Enzymes; Fema | 1982 |
14 other studies available for iohexol and Electrolytes
Article | Year |
---|---|
Sodium bicarbonate versus normal saline for protection against contrast nephropathy.
Topics: Aged; Cardiac Catheterization; Contrast Media; Coronary Angiography; Creatinine; Electrolytes; Glome | 2009 |
Incidence of ventricular fibrillation during left coronary arteriography in pigs: comparison of a solution of the nonionic dimer iodixanol with solutions of five different nonionic monomers.
Topics: Animals; Catheterization; Contrast Media; Coronary Angiography; Coronary Vessels; Electrolytes; Fema | 2008 |
CSF cation changes following subarachnoid injection of iohexol and metrizamide in rabbits.
Topics: Animals; Blood-Brain Barrier; Body Water; Contrast Media; Electrolytes; Injections, Spinal; Iodobenz | 1984 |
Contractile responses to electrolyte changes during coronary bolus perfusion. A comparative study in isolated rat, guinea pig, and rabbit hearts.
Topics: Analysis of Variance; Animals; Coronary Vessels; Electric Stimulation; Electrolytes; Guinea Pigs; Io | 1995 |
Cardiac effects of adding electrolytes and oxygen to iohexol in a dog model of contrast media-induced ventricular fibrillation.
Topics: Action Potentials; Animals; Dogs; Electrocardiography; Electrolytes; Female; Heart; Iohexol; Male; O | 1995 |
Comparison between oxygenated iohexol solution enriched with electrolytes and other low-osmotic contrast media. Electrophysiologic and hemodynamic effects during perfusion of the left coronary artery in the pig.
Topics: Animals; Contrast Media; Coronary Vessels; Electrocardiography; Electrolytes; Heart; Injections, Int | 1994 |
Cardiac effects of coronary arteriography with electrolyte addition to iohexol. A study in dogs with and without heart failure.
Topics: Animals; Blood Pressure; Calcium Chloride; Cardiac Output; Cardiac Output, Low; Coronary Angiography | 1994 |
Reduced risk of ventricular fibrillation by balancing sodium, calcium, potassium and magnesium added to nonionic contrast media. An investigation in the isolated rabbit heart.
Topics: Animals; Calcium; Electrolytes; Female; Heart; In Vitro Techniques; Iohexol; Magnesium; Male; Potass | 1993 |
Does the administration of systemic radiographic contrast media influence the acute changes in renal physiology following exposure to extracorporeal shock waves in dogs?
Topics: Acetylglucosaminidase; Aldosterone; Animals; Creatinine; Dogs; Electrolytes; Glomerular Filtration R | 1993 |
Electrolyte addition to nonionic contrast media. Cardiac effects during experimental coronary arteriography.
Topics: Animals; Anti-Arrhythmia Agents; Contrast Media; Coronary Angiography; Dogs; Electrolytes; Heart; He | 1996 |
Coronary arteriography with an oxygenated contrast medium: cardiac effects in dogs with and without acute ischemic heart failure.
Topics: Animals; Contrast Media; Coronary Angiography; Coronary Disease; Dogs; Electrolytes; Heart Failure; | 1996 |
Additive hemodynamic and electrophysiologic effects of repeated intracoronary contrast media injections in dogs with heart failure.
Topics: Animals; Contrast Media; Coronary Vessels; Dogs; Electrocardiography; Electrolytes; Heart Failure; H | 1995 |
Iohexol does not influence the levels of blood serum cation electrolytes during intravenous pyelography.
Topics: Adult; Aged; Cations; Contrast Media; Electrolytes; Female; Humans; Injections, Intravenous; Iohexol | 2001 |
The effect of nonionic radiographic contrast medium on serum electrolytes and proteins during intravenous urography.
Topics: Adult; Aged; Aged, 80 and over; Blood Proteins; Calcium; Contrast Media; Electrolytes; Female; Human | 1989 |