iohexol has been researched along with Aortic Stenosis in 11 studies
Iohexol: An effective non-ionic, water-soluble contrast agent which is used in myelography, arthrography, nephroangiography, arteriography, and other radiographic procedures. Its low systemic toxicity is the combined result of low chemotoxicity and low osmolality.
iohexol : A benzenedicarboxamide compound having N-(2,3-dihydroxypropyl)carbamoyl groups at the 1- and 3-positions, iodo substituents at the 2-, 4- and 6-positions and an N-(2,3-dihydroxypropyl)acetamido group at the 5-position.
Excerpt | Relevance | Reference |
---|---|---|
"Iodine load was reduced by 44%." | 1.48 | 320-row CT transcatheter aortic valve replacement planning with a single reduced contrast media bolus injection. ( El Ghannudi, S; Jeung, MY; Labani, A; Mata-Mbemba, D; Ohana, M; Ohlmann, P; Roy, C, 2018) |
Timeframe | Studies, this research(%) | All Research% |
---|---|---|
pre-1990 | 0 (0.00) | 18.7374 |
1990's | 1 (9.09) | 18.2507 |
2000's | 3 (27.27) | 29.6817 |
2010's | 7 (63.64) | 24.3611 |
2020's | 0 (0.00) | 2.80 |
Authors | Studies |
---|---|
de Santis, A | 1 |
Tarasoutchi, F | 1 |
Araujo Filho, JAB | 1 |
Vieira, MC | 1 |
Nomura, CH | 1 |
Katz, M | 1 |
Spina, GS | 1 |
Sampaio, RO | 1 |
Accorsi, TAD | 1 |
Rosa, VEE | 1 |
Fernandes, JRC | 1 |
Brown, J | 1 |
Edelman, ER | 1 |
Lemos, PA | 1 |
Mata-Mbemba, D | 1 |
Labani, A | 1 |
El Ghannudi, S | 1 |
Jeung, MY | 1 |
Ohlmann, P | 1 |
Roy, C | 1 |
Ohana, M | 1 |
Çakal, B | 1 |
Deniz Çakal, S | 1 |
Yıldırım, A | 1 |
Bandula, S | 1 |
White, SK | 1 |
Flett, AS | 1 |
Lawrence, D | 1 |
Pugliese, F | 1 |
Ashworth, MT | 1 |
Punwani, S | 1 |
Taylor, SA | 1 |
Moon, JC | 1 |
Dubourg, B | 1 |
Caudron, J | 1 |
Lestrat, JP | 1 |
Bubenheim, M | 1 |
Lefebvre, V | 1 |
Godin, M | 1 |
Tron, C | 1 |
Eltchaninoff, H | 1 |
Bauer, F | 1 |
Dacher, JN | 1 |
Schmidkonz, C | 1 |
Marwan, M | 1 |
Klinghammer, L | 1 |
Mitschke, M | 1 |
Schuhbaeck, A | 1 |
Arnold, M | 1 |
Lell, M | 1 |
Achenbach, S | 1 |
Pflederer, T | 1 |
Rajani, R | 1 |
Haworth, P | 1 |
Hildick-Smith, D | 1 |
Lehmkuhl, LH | 1 |
von Aspern, K | 1 |
Foldyna, B | 1 |
Grothoff, M | 1 |
Nitzsche, S | 1 |
Kempfert, J | 1 |
Rastan, A | 1 |
Linke, A | 1 |
Mohr, FW | 1 |
Noettling, A | 1 |
Walther, T | 1 |
Gutberlet, M | 1 |
Willmann, JK | 1 |
Wildermuth, S | 1 |
Pfammatter, T | 1 |
Roos, JE | 1 |
Seifert, B | 1 |
Hilfiker, PR | 1 |
Marincek, B | 1 |
Weishaupt, D | 1 |
Mühlenbruch, G | 1 |
Wildberger, JE | 1 |
Koos, R | 1 |
Das, M | 1 |
Thomas, C | 1 |
Ruhl, K | 1 |
Niethammer, M | 1 |
Floh, TG | 1 |
Stanzel, S | 1 |
Günther, RW | 1 |
Mahnken, AH | 1 |
Bristedt, P | 1 |
Tylén, U | 1 |
11 other studies available for iohexol and Aortic Stenosis
Article | Year |
---|---|
Topographic Pattern of Valve Calcification: A New Determinant of Disease Severity in Aortic Valve Stenosis.
Topics: Aged; Aortic Valve; Aortic Valve Stenosis; Calcinosis; Contrast Media; Female; Humans; Iohexol; Male | 2018 |
320-row CT transcatheter aortic valve replacement planning with a single reduced contrast media bolus injection.
Topics: Aged; Aged, 80 and over; Aorta; Aortic Valve; Aortic Valve Stenosis; Computed Tomography Angiography | 2018 |
Ultra-low-dose left ventricular injection-guided computed tomographic angiography prior to transcatheter aortic valve implantation: A novel technique for imaging.
Topics: Aged, 80 and over; Aortic Valve Stenosis; Computed Tomography Angiography; Contrast Media; Heart Ven | 2019 |
Measurement of myocardial extracellular volume fraction by using equilibrium contrast-enhanced CT: validation against histologic findings.
Topics: Aged; Aortic Valve Stenosis; Biopsy; Contrast Media; Endomyocardial Fibrosis; Extracellular Matrix; | 2013 |
Single-source dual-energy CT angiography with reduced iodine load in patients referred for aortoiliofemoral evaluation before transcatheter aortic valve implantation: impact on image quality and radiation dose.
Topics: Aged, 80 and over; Angiography; Aorta, Abdominal; Aortic Valve Stenosis; Contrast Media; Female; Fem | 2014 |
Interobserver variability of CT angiography for evaluation of aortic annulus dimensions prior to transcatheter aortic valve implantation (TAVI).
Topics: Aged, 80 and over; Aortic Valve; Aortic Valve Stenosis; Body Weights and Measures; Contrast Media; F | 2014 |
The incidence of nephropathy in patients undergoing transcatheter aortic valve implantation.
Topics: Aortic Valve Stenosis; Cardiac Catheterization; Contrast Media; Glomerular Filtration Rate; Heart Va | 2009 |
Comparison of aortic root measurements in patients undergoing transapical aortic valve implantation (TA-AVI) using three-dimensional rotational angiography (3D-RA) and multislice computed tomography (MSCT): differences and variability.
Topics: Aged; Aged, 80 and over; Aorta, Thoracic; Aortic Valve; Aortic Valve Stenosis; Cardiac Catheterizati | 2013 |
Aortoiliac and renal arteries: prospective intraindividual comparison of contrast-enhanced three-dimensional MR angiography and multi-detector row CT angiography.
Topics: Aged; Aged, 80 and over; Angiography, Digital Subtraction; Aortic Aneurysm, Abdominal; Aortic Valve | 2003 |
Calcium scoring of aortic valve calcification in aortic valve stenosis with a multislice computed tomography scanner: non-enhanced versus contrast-enhanced studies.
Topics: Aortic Valve; Aortic Valve Stenosis; Calcinosis; Contrast Media; Electrocardiography; Female; Heart | 2005 |
Pulmonary edema following intravenous injection of nonionic low-osmolar contrast medium--appearance on HRCT. A case report.
Topics: Aged; Aortic Valve Stenosis; Contrast Media; Female; Follow-Up Studies; Humans; Image Enhancement; I | 1998 |