Page last updated: 2024-10-29

iohexol and Aortic Aneurysm

iohexol has been researched along with Aortic Aneurysm in 17 studies

Iohexol: An effective non-ionic, water-soluble contrast agent which is used in myelography, arthrography, nephroangiography, arteriography, and other radiographic procedures. Its low systemic toxicity is the combined result of low chemotoxicity and low osmolality.
iohexol : A benzenedicarboxamide compound having N-(2,3-dihydroxypropyl)carbamoyl groups at the 1- and 3-positions, iodo substituents at the 2-, 4- and 6-positions and an N-(2,3-dihydroxypropyl)acetamido group at the 5-position.

Aortic Aneurysm: An abnormal balloon- or sac-like dilatation in the wall of AORTA.

Research Excerpts

ExcerptRelevanceReference
"To evaluate whether MR angiography (MRA) is a useful tool for the follow-up of aortic aneurysms treated with nitinol endoluminal grafts."9.11MRA is useful as a follow-up technique after endovascular repair of aortic aneurysms with nitinol endoprostheses. ( Ayuso, C; Ayuso, JR; de Caralt, TM; Montaña, X; Pages, M; Real, MI; Riambau, V; Sanchez, M, 2004)
"To evaluate whether MR angiography (MRA) is a useful tool for the follow-up of aortic aneurysms treated with nitinol endoluminal grafts."5.11MRA is useful as a follow-up technique after endovascular repair of aortic aneurysms with nitinol endoprostheses. ( Ayuso, C; Ayuso, JR; de Caralt, TM; Montaña, X; Pages, M; Real, MI; Riambau, V; Sanchez, M, 2004)
"Acute aortic dissection (AAD) is a life-threatening condition making early diagnosis critical."1.48Variation in emergency department use of computed tomography for investigation of acute aortic dissection. ( Anjum, O; Bleeker, H; Ohle, R; Perry, JJ; Wells, G, 2018)
"120 patients with known or suspected aortic dissection underwent aortic CTA and were equally divided into 3 groups."1.46Iterative reconstruction in single-source dual-energy CT angiography: feasibility of low and ultra-low volume contrast medium protocols. ( Feng, X; Gao, J; Hou, P; Jiang, X; Jiang, Y; Liu, J; Zhou, Y, 2017)
"False lumen thrombosis after aortic dissection is a major predictor of prognosis."1.37A new method for quantification of false lumen thrombosis in aortic dissection using magnetic resonance imaging and a blood pool contrast agent. ( Clough, RE; Greil, GF; Hussain, T; Razavi, R; Schaeffter, T; Taylor, PR; Uribe, S; Waltham, M, 2011)

Research

Studies (17)

TimeframeStudies, this research(%)All Research%
pre-19900 (0.00)18.7374
1990's1 (5.88)18.2507
2000's7 (41.18)29.6817
2010's8 (47.06)24.3611
2020's1 (5.88)2.80

Authors

AuthorsStudies
Hsieh, CC1
Zeng, AB1
Chen, CH1
Jhou, ZY1
Wang, CH1
Yang, YL1
Hsieh, FC1
Lin, JK1
Yeh, JY1
Huang, CC1
Yeo, LLL1
Holmin, S1
Andersson, T1
Lundström, E1
Gopinathan, A1
Lim, EL1
Leong, BSH1
Kuan, WS1
Ting, E1
Tan, BYQ1
Eide, SE1
Tay, ELK1
Hou, P1
Feng, X1
Liu, J1
Zhou, Y1
Jiang, Y1
Jiang, X1
Gao, J1
Ohle, R1
Anjum, O1
Bleeker, H1
Wells, G1
Perry, JJ1
Guo, ZJ1
Lin, Q1
Zi, XR1
Xu, Q1
Liu, HT1
Lu, JY1
Chi, HW1
Wang, JX1
Cao, B1
Zhao, BH1
Zhang, YH1
Sueyoshi, E1
Onizuka, H1
Nagayama, H1
Sakamoto, I1
Uetani, M1
Shuman, WP1
O'Malley, RB1
Busey, JM1
Ramos, MM1
Koprowicz, KM1
Nakayama, Y1
Awai, K1
Yanaga, Y1
Nakaura, T1
Funama, Y1
Hirai, T1
Yamashita, Y1
Tsai, IC1
Fu, YC1
Lin, PC1
Lin, MC1
Jan, SL1
Behrendt, FF1
Schmidt, B1
Plumhans, C1
Keil, S1
Woodruff, SG1
Ackermann, D1
Mühlenbruch, G1
Flohr, T1
Günther, RW1
Mahnken, AH1
Kovács, A1
Schiller, W1
Gerhards, HM1
Welz, A1
Willinek, WA1
Schild, H1
Urbach, H1
Flacke, S1
Cornfeld, D1
Israel, G1
Detroy, E1
Bokhari, J1
Mojibian, H1
Clough, RE1
Hussain, T1
Uribe, S1
Greil, GF1
Razavi, R1
Taylor, PR1
Schaeffter, T1
Waltham, M1
Erley, CM1
Bader, BD1
Berger, ED1
Tuncel, N1
Winkler, S1
Tepe, G1
Risler, T1
Duda, S1
Ayuso, JR1
de Caralt, TM1
Pages, M1
Riambau, V1
Ayuso, C1
Sanchez, M1
Real, MI1
Montaña, X1
Hirai, N1
Imakita, S1
Tanaka, R1
Higashi, M1
Nishino, T1
Naito, H1
Ito, K1
Becker, C1
von Smekal, A1
Knez, A1
Wintersperger, BJ1
Behr, J1
Reiser, M1

Clinical Trials (1)

Trial Overview

TrialPhaseEnrollmentStudy TypeStart DateStatus
The Best Parameters for Imaging Agent Injection and Scanning Methods in Computed Tomography Angiography[NCT04832633]101 participants (Actual)Interventional2018-03-01Completed
[information is prepared from clinicaltrials.gov, extracted Sep-2024]

Trials

4 trials available for iohexol and Aortic Aneurysm

ArticleYear
Optimal contrast medium injection protocols for the depiction of the Adamkiewicz artery using 64-detector CT angiography.
    Clinical radiology, 2008, Volume: 63, Issue:8

    Topics: Adult; Aged; Aged, 80 and over; Angiography; Aortic Aneurysm; Aortography; Contrast Media; Drug Admi

2008
Gadolinium-based contrast media compared with iodinated media for digital subtraction angiography in azotaemic patients.
    Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association, 2004, Volume: 19, Issue:10

    Topics: Aged; Angiography, Digital Subtraction; Aortic Aneurysm; Contrast Media; Double-Blind Method; Female

2004
MRA is useful as a follow-up technique after endovascular repair of aortic aneurysms with nitinol endoprostheses.
    Journal of magnetic resonance imaging : JMRI, 2004, Volume: 20, Issue:5

    Topics: Alloys; Aortic Aneurysm; Blood Vessel Prosthesis; Contrast Media; Creatinine; Follow-Up Studies; Hum

2004
Multidetector CT angiography using a dual-head power injector and bolus tracking for the diagnosis of aortic aneurysms at reduced contrast material dosage.
    Academic radiology, 2006, Volume: 13, Issue:6

    Topics: Aged; Angiography; Aortic Aneurysm; Contrast Media; Dose-Response Relationship, Drug; Equipment Desi

2006

Other Studies

13 other studies available for iohexol and Aortic Aneurysm

ArticleYear
A practical biphasic contrast media injection protocol strongly enhances the aorta and pulmonary artery simultaneously using a single CT angiography scan.
    BMC medical imaging, 2021, 10-30, Volume: 21, Issue:1

    Topics: Aged; Aortic Aneurysm; Aortic Dissection; Computed Tomography Angiography; Contrast Media; Female; H

2021
Nongated Cardiac Computed Tomographic Angiograms for Detection of Embolic Sources in Acute Ischemic Stroke.
    Stroke, 2017, Volume: 48, Issue:5

    Topics: Aged; Aorta, Thoracic; Aortic Aneurysm; Aortic Dissection; Atrial Appendage; Brain Ischemia; Compute

2017
Iterative reconstruction in single-source dual-energy CT angiography: feasibility of low and ultra-low volume contrast medium protocols.
    The British journal of radiology, 2017, Volume: 90, Issue:1075

    Topics: Aortic Aneurysm; Aortic Dissection; Computed Tomography Angiography; Contrast Media; Feasibility Stu

2017
Variation in emergency department use of computed tomography for investigation of acute aortic dissection.
    Emergency radiology, 2018, Volume: 25, Issue:3

    Topics: Acute Disease; Adult; Aged; Aortic Aneurysm; Aortic Dissection; Contrast Media; Diagnosis, Different

2018
Correlation of computed tomography angiography parameters and shock index to assess the transportation risk in aortic dissection patients.
    La Radiologia medica, 2015, Volume: 120, Issue:4

    Topics: Adolescent; Adult; Aged; Aged, 80 and over; Angiography; Aortic Aneurysm; Aortic Dissection; Contras

2015
Clinical importance of minimal enhancement of type B intramural hematoma of the aorta on computed tomography imaging.
    Journal of vascular surgery, 2017, Volume: 65, Issue:1

    Topics: Adult; Aged; Aged, 80 and over; Aortic Aneurysm; Aortic Dissection; Aortography; Chi-Square Distribu

2017
Prospective comparison of dual-energy CT aortography using 70% reduced iodine dose versus single-energy CT aortography using standard iodine dose in the same patient.
    Abdominal radiology (New York), 2017, Volume: 42, Issue:3

    Topics: Aged; Aortic Aneurysm; Computed Tomography Angiography; Contrast Media; Female; Humans; Iohexol; Mal

2017
MDCT evaluation of congenital mitral-aortic intervalvular fibrosa aneurysm: implications for the aetiology and differential diagnosis.
    Pediatric radiology, 2009, Volume: 39, Issue:1

    Topics: Aortic Aneurysm; Aortic Valve; Contrast Media; Diagnosis, Differential; Echocardiography; Humans; In

2009
Image fusion in dual energy computed tomography: effect on contrast enhancement, signal-to-noise ratio and image quality in computed tomography angiography.
    Investigative radiology, 2009, Volume: 44, Issue:1

    Topics: Aged; Aged, 80 and over; Algorithms; Angiography; Aortic Aneurysm; Aortography; Contrast Media; Fema

2009
Visualization of the Adamkiewicz artery in patients with acute stanford a dissections: a prospective 64-row multi-detector CT study.
    RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 2009, Volume: 181, Issue:9

    Topics: Adult; Aged; Aortic Aneurysm; Aortic Dissection; Aortography; Arteries; Artifacts; Contrast Media; F

2009
Impact of Adaptive Statistical Iterative Reconstruction (ASIR) on radiation dose and image quality in aortic dissection studies: a qualitative and quantitative analysis.
    AJR. American journal of roentgenology, 2011, Volume: 196, Issue:3

    Topics: Adult; Aged; Aged, 80 and over; Angiography; Aortic Aneurysm; Aortic Dissection; Contrast Media; Fem

2011
A new method for quantification of false lumen thrombosis in aortic dissection using magnetic resonance imaging and a blood pool contrast agent.
    Journal of vascular surgery, 2011, Volume: 54, Issue:5

    Topics: Adult; Aged; Aged, 80 and over; Aortic Aneurysm; Aortic Dissection; Aortography; Chronic Disease; Co

2011
[Demonstration by spiral CT of an aneurysm of the left sinus of Valsalva].
    RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 1997, Volume: 167, Issue:4

    Topics: Aortic Aneurysm; Contrast Media; Echocardiography; Humans; Iohexol; Male; Middle Aged; Sinus of Vals

1997