Page last updated: 2024-10-29

iodixanol and Sensitivity and Specificity

iodixanol has been researched along with Sensitivity and Specificity in 69 studies

iodixanol: dimeric contrast media; structure given in first source
iodixanol : A dimeric, non-ionic, water-soluble, radiographic contrast agent, used particularly in coronary angiography.

Sensitivity and Specificity: Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed)

Research Excerpts

ExcerptRelevanceReference
" This double blind, comparative, randomized, parallel trial compared the efficacy of iodixanol (non-ionic dimer) and iopromide (non-ionic monomer) in 100 patients with mild to moderate renal insufficiency (serum creatinine of 135 to 265 mumol l-1) who underwent i."9.08Comparison between the efficacy of dimeric and monomeric non-ionic contrast media (iodixanol vs iopromide) in urography in patients with mild to moderate renal insufficiency. ( Assante, M; Cova, M; Haider, T; Hougens Grynne, B; Stacul, F, 1998)
"To compare iomeprol 400 and iodixanol 320 in pulmonary artery MDCTA in subjects with suspected pulmonary embolism."5.14MDCT angiography for detection of pulmonary emboli: comparison between equi-iodine doses of iomeprol 400 mgI/mL and iodixanol 320 mgI/mL. ( Friedrich, K; Herold, C; Langenberger, H; Matzek, W; Plank, C; Schaefer-Prokop, C; Storto, ML; Wolf, F, 2009)
" This double blind, comparative, randomized, parallel trial compared the efficacy of iodixanol (non-ionic dimer) and iopromide (non-ionic monomer) in 100 patients with mild to moderate renal insufficiency (serum creatinine of 135 to 265 mumol l-1) who underwent i."5.08Comparison between the efficacy of dimeric and monomeric non-ionic contrast media (iodixanol vs iopromide) in urography in patients with mild to moderate renal insufficiency. ( Assante, M; Cova, M; Haider, T; Hougens Grynne, B; Stacul, F, 1998)
"Atrio-oesophageal fistula is a rare but often fatal complication of catheter ablation for atrial fibrillation (AF)."2.79Assessment of oesophageal position by direct visualization with luminal contrast compared with segmentation from pre-acquired computed tomography scan-implications for ablation strategy. ( Gavin, AR; McGavigan, AD; Singleton, CB, 2014)
"Iodixanol at both doses was diagnostic in over 90% of cases."2.69A comparison of a non-ionic dimer, iodixanol with a non-ionic monomer, iohexol in low dose intravenous urography. ( Bjartveit, K; Carlsen, SD; Gibney, RG; Greaney, T; Kampenes, VB; Lindequist, S; Masterson, J; Moller-Nielsen, S; Rasmussen, F; Skehan, SJ; Svaland, MG, 1998)
"Iodixanol is a new nonionic dimer, isotonic with blood at all clinically relevant concentrations."2.69Iodixanol in cerebral computed tomography: a randomized, double-blind, phase-III, parallel study with iodixanol and iohexol. ( Doerfler, A; Fiebach, J; Forsting, M; Henseke, P; Sartor, K; Wanke, I, 1999)
"51 females clinically suspected for ovarian cancer recurrence underwent 3-T WB-DWI/MRI in addition to contrast-enhanced CT."1.43Whole-body diffusion-weighted magnetic resonance imaging in the diagnosis of recurrent ovarian cancer: a clinical feasibility study. ( Amant, F; De Keyzer, F; Dresen, R; Fieuws, S; Leunen, K; Michielsen, KL; Moerman, P; Op de Beeck, K; Vandecaveye, V; Vanslembrouck, R; Vergote, I, 2016)
"CTTA software was used to analyze 20 clear cell renal cell carcinomas (RCCs), 20 papillary RCCs, 20 oncocytomas, and 20 renal cysts."1.40CT texture analysis of renal masses: pilot study using random forest classification for prediction of pathology. ( Chen, Y; Fishman, EK; Huang, P; Raman, SP; Schroeder, JL, 2014)
"To assess the feasibility of colorectal cancer detection using dual-energy computed tomography with iodine mapping and without bowel preparation or bowel distension."1.39The feasibility of colorectal cancer detection using dual-energy computed tomography with iodine mapping. ( Boellaard, TN; Henneman, OD; Nio, CY; Stoker, J; Streekstra, GJ; van Dorth-Rombouts, MC; Venema, HW, 2013)
"For detection of bladder tumors, there was higher sensitivity for the UP than the EP (89."1.38Detection of urothelial tumors: comparison of urothelial phase with excretory phase CT urography--a prospective study. ( Chawla, TP; Fleshner, NE; Goldstein, MA; Jacks, LM; Metser, U; O'Malley, ME, 2012)
"Once presence of a colorectal cancer has been diagnosed, a key factor for patient's prognosis in view of surgical intervention is the correct segmental localization and resection of the tumor."1.36Comparison of CT colonography vs. conventional colonoscopy in mapping the segmental location of colon cancer before surgery. ( Bartolozzi, C; Cerri, F; Faggioni, L; Naldini, G; Neri, E; Turini, F; Vagli, P, 2010)
"When cecal volvulus is suspected, the absence of distal colonic decompression on CT topograms makes the diagnosis very unlikely."1.36Findings of cecal volvulus at CT. ( Den, EI; DuBrow, RA; Levsky, JM; Rosenblat, JM; Rozenblit, AM; Wolf, EL, 2010)
"Five ruptured aneurysms in patients with a nonperimesencephalic SAH were negative on CTA, and four of these were also false-negative on IA-DSA."1.34Multislice CT angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling. ( Fiore, D; Gravendeel, J; Groen, RJ; Metzemaekers, JD; Mooij, JJ; Oudkerk, M; Westerlaan, HE, 2007)

Research

Studies (69)

TimeframeStudies, this research(%)All Research%
pre-19900 (0.00)18.7374
1990's7 (10.14)18.2507
2000's21 (30.43)29.6817
2010's41 (59.42)24.3611
2020's0 (0.00)2.80

Authors

AuthorsStudies
Helyar, VG1
Gupta, Y1
Blakeway, L1
Charles-Edwards, G1
Katsanos, K2
Karunanithy, N1
Huang, G1
Lebovic, G1
Vlachou, PA1
Di Piazza, A1
Mamone, G1
Caruso, S1
Marrone, G1
Tuzzolino, F1
Vitulo, P1
Bertani, A1
Miraglia, R1
Lovy, AJ1
Rosenblum, JK1
Levsky, JM3
Godelman, A2
Zalta, B1
Jain, VR2
Haramati, LB2
Choudhri, AF1
Norton, PT1
Carr, TM1
Stone, JR1
Hagspiel, KD1
Dake, MD1
Boellaard, TN1
Henneman, OD1
Streekstra, GJ1
Venema, HW1
Nio, CY1
van Dorth-Rombouts, MC1
Stoker, J1
Frick, K1
Michael, TT1
Alomar, M1
Mohammed, A1
Rangan, BV1
Abdullah, S1
Grodin, J1
Hastings, JL1
Banerjee, S1
Brilakis, ES1
Jang, HJ1
Kim, TK1
Khalili, K1
Yazdi, L1
Menezes, R1
Park, SH1
Sherman, M1
Ba-Ssalamah, A1
Muin, D1
Schernthaner, R1
Kulinna-Cosentini, C1
Bastati, N1
Stift, J1
Gore, R1
Mayerhoefer, ME1
Caroff, J1
Jittapiromsak, P1
Ruijters, D1
Benachour, N1
Mihalea, C1
Rouchaud, A1
Neki, H1
Ikka, L1
Moret, J1
Spelle, L1
Gavin, AR1
Singleton, CB1
McGavigan, AD1
Raman, SP1
Chen, Y1
Schroeder, JL1
Huang, P1
Fishman, EK1
Zheng, M1
Wu, Y1
Wei, M1
Liu, Y1
Zhao, H1
Li, J1
Stehli, J1
Fuchs, TA1
Singer, A1
Bull, S1
Clerc, OF1
Possner, M1
Gaemperli, O2
Buechel, RR1
Kaufmann, PA2
Budoff, MJ2
Bloom, SA1
Chow, BJ1
Chandler, AB1
Cole, JH1
Andersen, MB1
Harders, SW1
Ganeshan, B1
Thygesen, J1
Torp Madsen, HH1
Rasmussen, F2
Spagnoli, V1
Amabile, N1
Dillinger, JG1
Veugeois, A1
Logeart, D1
Henry, P1
Caussin, C1
Slama, MS1
Valero, E1
Rodríguez, JC1
Moyano, P1
Miñana, G1
Sanchis, J1
Núñez, J1
Nakazato, R1
Arsanjani, R1
Shalev, A1
Leipsic, JA1
Gransar, H1
Lin, FY2
Gomez, M1
Berman, DS1
Min, JK2
Michielsen, KL1
Vergote, I1
Dresen, R1
Op de Beeck, K1
Vanslembrouck, R1
Amant, F1
Leunen, K1
Moerman, P1
Fieuws, S1
De Keyzer, F1
Vandecaveye, V1
Li, D1
Kazerooni, EA1
Thomas, GS1
Mieres, JH1
Shaw, LJ1
Hwang, JY1
Choo, KS1
Choi, YY1
Kim, JH1
Ryu, H1
Han, J1
Kim, YW1
Jeon, UB1
Nam, KJ1
De Filippo, M1
Bertellini, A1
Sverzellati, N1
Pogliacomi, F1
Costantino, C1
Vitale, M1
Zappia, M1
Corradi, D1
Garlaschi, G1
Zompatori, M1
Cury, RC1
Nieman, K2
Shapiro, MD1
Butler, J1
Nomura, CH1
Ferencik, M1
Hoffmann, U1
Abbara, S1
Jassal, DS1
Yasuda, T1
Gold, HK1
Jang, IK1
Brady, TJ1
Stolzmann, P1
Frauenfelder, T2
Pfammatter, T1
Peter, N1
Scheffel, H3
Lachat, M1
Schmidt, B1
Marincek, B2
Alkadhi, H2
Schertler, T1
Ulimoen, GR1
Gjønnaess, E1
Atar, D1
Dahl, T1
Stranden, E1
Sandbaek, G1
Fisichella, VA1
Jäderling, F1
Horvath, S1
Stotzer, PO1
Kilander, A1
Hellström, M1
Loewe, C1
Neri, E1
Turini, F1
Cerri, F1
Faggioni, L1
Vagli, P1
Naldini, G1
Bartolozzi, C1
LaBounty, TM1
Glasofer, S1
Devereux, RB1
Weinsaft, JW1
Jaskolka, JD1
Kwok, RP1
Gray, SH1
Mojibian, HR1
Maheshwari, E1
O'Malley, ME2
Ghai, S1
Staunton, M1
Massey, C1
Shah, RG1
Novaro, GM1
Blandon, RJ1
Wilkinson, L1
Asher, CR1
Kirsch, J1
Deschamps, F1
Solomon, SB1
Thornton, RH1
Rao, P1
Hakime, A1
Kuoch, V1
de Baere, T1
Rosenblat, JM1
Rozenblit, AM1
Wolf, EL1
DuBrow, RA1
Den, EI1
Krauss, T1
Strebel, RT1
Birzele, J1
Seifert, B1
Goerres, GW1
Salati, U1
McNeill, G1
Torreggiani, WC1
Antunez, C1
Barbaud, A1
Gomez, E1
Audonnet, S1
Lopez, S1
Guéant-Rodriguez, RM1
Aimone-Gastin, I1
Gomez, F1
Blanca, M1
Guéant, JL1
Shankar, JJ1
Tan, IY1
Krings, T1
Terbrugge, K1
Agid, R1
Bellemain-Appaix, A1
Beygui, F1
Lesty, C1
Gupta, S1
Silvain, J1
Le Feuvre, C1
Cayla, G1
Allali, Y1
Montalescot, G1
Collet, JP1
Steinwender, G1
Szolar, D1
Preidler, K1
Tillich, M1
Zweiker, R1
Watzinger, N1
Carrafiello, G1
Fontana, F1
Mangini, M1
Ierardi, AM1
Cotta, E1
Piacentino, F1
De Chiara, M1
Floridi, C1
Di Massa, A1
Marconi, AM1
Fugazzola, C1
Haneder, S1
Augustin, J1
Jost, G1
Pietsch, H1
Lengsfeld, P1
Krämer, BK1
Schoenberg, SO1
Meyer, M1
Attenberger, UI1
Michaely, HJ1
Hur, J1
Kim, YJ1
Lee, HJ1
Nam, JE1
Hong, YJ1
Kim, HY1
Lee, JW1
Choi, BW1
Metser, U1
Goldstein, MA1
Chawla, TP1
Fleshner, NE1
Jacks, LM1
Baron, KT1
Arleo, EK1
Robinson, C1
Sanelli, PC1
La Grutta, L1
Galia, M1
Gentile, G1
Lo Re, G1
Grassedonio, E1
Coppolino, F1
Maffei, E1
Maresi, E1
Lo Casto, A1
Cademartiri, F2
Midiri, M1
Spiro, AJ1
Travin, MI1
Mollet, N1
van der Lugt, A1
Pattynama, PM1
de Feyter, PJ1
Krestin, GP1
Sabharwal, R1
Vladica, P1
Chou, R1
Law, WP1
Kolnes, K1
Velle, OH1
Hareide, S1
Hegbom, K1
Wiseth, R1
Cheng, PM1
Van Allan, RJ1
Kagadis, GC1
Spyridonos, P1
Karnabatidis, D1
Diamantopoulos, A1
Athanasiadis, E1
Daskalakis, A1
Cavouras, D1
Mihailidis, D1
Siablis, D1
Nikiforidis, GC1
Westerlaan, HE1
Gravendeel, J1
Fiore, D1
Metzemaekers, JD1
Groen, RJ1
Mooij, JJ1
Oudkerk, M1
Brisman, JL1
Jilani, M1
McKinney, JS1
Larsen, LP1
Rosenkilde, M1
Christensen, H1
Bang, N1
Bolvig, L1
Christiansen, T1
Laurberg, S1
Valenta, I1
Schepis, T1
Husmann, L1
Desbiolles, L1
Leschka, S1
Sauer, B1
Flocquet, M1
Batch, T1
Blum, A1
Hubert, J1
Akram, K1
Voros, S1
Takaki, MT1
Dubinsky, TJ1
Warren, BH1
Mitsumori, L1
Shuman, WP1
Langenberger, H1
Friedrich, K1
Plank, C1
Matzek, W1
Wolf, F1
Storto, ML1
Schaefer-Prokop, C1
Herold, C1
Sapoval, MR1
Beyssen, BM1
Girardot, C1
Musset, MA1
Legmann, P1
Brekke, O1
Gaux, JC1
Leander, P1
Golman, K1
Harnish, P1
Fountaine, H1
Carlier, RY1
Akeson, P1
Morvan, G1
Kristoffersen, DT1
Amar, C1
Vallée, C1
Skehan, SJ1
Gibney, RG1
Lindequist, S1
Moller-Nielsen, S1
Svaland, MG1
Kampenes, VB1
Bjartveit, K1
Greaney, T1
Carlsen, SD1
Masterson, J1
Stacul, F1
Cova, M1
Assante, M1
Hougens Grynne, B1
Haider, T1
Doerfler, A1
Fiebach, J1
Wanke, I1
Forsting, M1
Henseke, P1
Sartor, K1
Jacobsen, PB1

Clinical Trials (2)

Trial Overview

TrialPhaseEnrollmentStudy TypeStart DateStatus
Acute Chest Pain Imaging in Emergency Department With Combined Approach of Coronary CT Angiography and CT Myocardial Perfusion[NCT02538861]250 participants (Actual)Observational2015-09-30Completed
Interobserver Agreement of Determination of Hepatocellular Carcinoma Feeding Vessels : Multi-Detector CT Angiography With 3D Reconstruction Versus Digital Subtraction Angiography[NCT05304572]70 participants (Actual)Observational2022-05-01Completed
[information is prepared from clinicaltrials.gov, extracted Sep-2024]

Trials

16 trials available for iodixanol and Sensitivity and Specificity

ArticleYear
Use of time attenuation curves to determine steady-state characteristics before C-arm CT measurement of cerebral blood volume.
    Neuroradiology, 2014, Volume: 56, Issue:3

    Topics: Adolescent; Adult; Aged; Aged, 80 and over; Blood Flow Velocity; Blood Volume; Blood Volume Determin

2014
Assessment of oesophageal position by direct visualization with luminal contrast compared with segmentation from pre-acquired computed tomography scan-implications for ablation strategy.
    Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 2014, Volume: 16, Issue:9

    Topics: Atrial Fibrillation; Catheter Ablation; Contrast Media; Esophageal Fistula; Esophagus; Fluoroscopy;

2014
Low-concentration contrast medium for 128-slice dual-source CT coronary angiography at a very low radiation dose using prospectively ECG-triggered high-pitch spiral acquisition.
    Academic radiology, 2015, Volume: 22, Issue:2

    Topics: Adult; Cardiac-Gated Imaging Techniques; Contrast Media; Coronary Angiography; Coronary Artery Disea

2015
Diagnostic Accuracy, Image Quality, and Patient Comfort for Coronary CT Angiography Performed Using Iso-Osmolar versus Low-Osmolar Iodinated Contrast: A Prospective International Multicenter Randomized Controlled Trial.
    Academic radiology, 2016, Volume: 23, Issue:6

    Topics: Computed Tomography Angiography; Contrast Media; Coronary Angiography; Coronary Artery Disease; Fema

2016
Multidetector computed tomography arthrography of the shoulder: diagnostic accuracy and indications.
    Acta radiologica (Stockholm, Sweden : 1987), 2008, Volume: 49, Issue:5

    Topics: Adult; Arthralgia; Arthrography; Arthroscopy; Contraindications; Contrast Media; Female; Humans; Ima

2008
Noninvasive coronary angiography with 64-channel multidetector computed tomography in patients with acute coronary syndrome.
    Acta radiologica (Stockholm, Sweden : 1987), 2008, Volume: 49, Issue:10

    Topics: Acute Coronary Syndrome; Adult; Aged; Aged, 80 and over; Angina, Unstable; Contrast Media; Coronary

2008
Impact of anticoagulation on ionic and nonionic contrast media effect on thrombogenesis and fibrinolysis: The PEPCIT study.
    Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions, 2012, Apr-01, Volume: 79, Issue:5

    Topics: Aged; Angioplasty, Balloon, Coronary; Anticoagulants; Contrast Media; Coronary Angiography; Coronary

2012
Impact of iso- and low-osmolar iodinated contrast agents on BOLD and diffusion MRI in swine kidneys.
    Investigative radiology, 2012, Volume: 47, Issue:5

    Topics: Animals; Contrast Media; Diffusion Magnetic Resonance Imaging; Female; Iohexol; Kidney; Osmolar Conc

2012
Non-invasive 16-row multislice CT coronary angiography: usefulness of saline chaser.
    European radiology, 2004, Volume: 14, Issue:2

    Topics: Adult; Aged; Aortography; Contrast Media; Coronary Angiography; Coronary Artery Disease; Dose-Respon

2004
Helical CT in the diagnosis of acute lower gastrointestinal haemorrhage.
    European journal of radiology, 2006, Volume: 58, Issue:2

    Topics: Acute Disease; Aged; Aged, 80 and over; Angiography, Digital Subtraction; Colonoscopy; Contrast Medi

2006
MDCT angiography for detection of pulmonary emboli: comparison between equi-iodine doses of iomeprol 400 mgI/mL and iodixanol 320 mgI/mL.
    European journal of radiology, 2009, Volume: 70, Issue:3

    Topics: Aged; Angiography; Contrast Media; Dose-Response Relationship, Drug; Female; Humans; Iopamidol; Male

2009
Iodixanol in leg phlebography: a randomized, double-blind parallel group phase III trial comparing iodixanol to ioxaglate.
    Clinical radiology, 1996, Volume: 51, Issue:3

    Topics: Adult; Aged; Contrast Media; Double-Blind Method; Female; Humans; Ioxaglic Acid; Leg; Male; Middle A

1996
Time dependence of iopamidol and iodixanol in arthrography of the knee.
    Acta radiologica (Stockholm, Sweden : 1987), 1999, Volume: 40, Issue:1

    Topics: Arthrography; Contrast Media; Double-Blind Method; Humans; Image Enhancement; Iopamidol; Knee Joint;

1999
A comparison of a non-ionic dimer, iodixanol with a non-ionic monomer, iohexol in low dose intravenous urography.
    The British journal of radiology, 1998, Volume: 71, Issue:849

    Topics: Adult; Aged; Contrast Media; Double-Blind Method; Humans; Iohexol; Middle Aged; Prospective Studies;

1998
Comparison between the efficacy of dimeric and monomeric non-ionic contrast media (iodixanol vs iopromide) in urography in patients with mild to moderate renal insufficiency.
    The British journal of radiology, 1998, Volume: 71, Issue:849

    Topics: Adult; Aged; Contrast Media; Double-Blind Method; Female; Humans; Iohexol; Male; Middle Aged; Observ

1998
Iodixanol in cerebral computed tomography: a randomized, double-blind, phase-III, parallel study with iodixanol and iohexol.
    European radiology, 1999, Volume: 9, Issue:7

    Topics: Adult; Aged; Aged, 80 and over; Brain; Contrast Media; Dose-Response Relationship, Drug; Double-Blin

1999

Other Studies

53 other studies available for iodixanol and Sensitivity and Specificity

ArticleYear
Depiction of lower limb venous anatomy in patients undergoing interventional deep venous reconstruction-the role of balanced steady state free precession MRI.
    The British journal of radiology, 2018, Volume: 91, Issue:1082

    Topics: Adolescent; Adult; Aged; Angiography, Digital Subtraction; Contrast Media; Female; Humans; Iohexol;

2018
Diagnostic Value of CT in Detecting Peripheral Zone Prostate Cancer.
    AJR. American journal of roentgenology, 2019, Volume: 213, Issue:4

    Topics: Adenocarcinoma; Aged; Biopsy; Contrast Media; Humans; Male; Middle Aged; Neoplasm Staging; Predictiv

2019
Acute rejection after lung transplantation: association between histopathological and CT findings.
    La Radiologia medica, 2019, Volume: 124, Issue:10

    Topics: Acute Disease; Adult; Biopsy; Bronchoalveolar Lavage; Contrast Media; Female; Graft Rejection; Human

2019
Acute aortic syndromes: a second look at dual-phase CT.
    AJR. American journal of roentgenology, 2013, Volume: 200, Issue:4

    Topics: Acute Disease; Aged; Aged, 80 and over; Aortic Diseases; Aortography; Case-Control Studies; Chi-Squa

2013
Diagnosis and treatment planning of acute aortic emergencies using a handheld DICOM viewer.
    Emergency radiology, 2013, Volume: 20, Issue:4

    Topics: Acute Disease; Adult; Aged; Angiography; Aortic Diseases; Cell Phone; Computers, Handheld; Contrast

2013
The feasibility of colorectal cancer detection using dual-energy computed tomography with iodine mapping.
    Clinical radiology, 2013, Volume: 68, Issue:8

    Topics: Adenocarcinoma; Aged; Aged, 80 and over; Colonoscopy; Colorectal Neoplasms; Contrast Media; Feasibil

2013
Low molecular weight dextran provides similar optical coherence tomography coronary imaging compared to radiographic contrast media.
    Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions, 2014, Nov-01, Volume: 84, Issue:5

    Topics: Aged; Cohort Studies; Contrast Media; Coronary Angiography; Coronary Artery Disease; Dextrans; Human

2014
Characterization of 1-to 2-cm liver nodules detected on hcc surveillance ultrasound according to the criteria of the American Association for the Study of Liver Disease: is quadriphasic CT necessary?
    AJR. American journal of roentgenology, 2013, Volume: 201, Issue:2

    Topics: Adult; Aged; Carcinoma, Hepatocellular; Contrast Media; Female; Humans; Liver Neoplasms; Logistic Mo

2013
Texture-based classification of different gastric tumors at contrast-enhanced CT.
    European journal of radiology, 2013, Volume: 82, Issue:10

    Topics: Adult; Aged; Aged, 80 and over; Algorithms; Diagnosis, Differential; Female; Humans; Imaging, Three-

2013
CT texture analysis of renal masses: pilot study using random forest classification for prediction of pathology.
    Academic radiology, 2014, Volume: 21, Issue:12

    Topics: Adenoma, Oxyphilic; Aged; Carcinoma, Renal Cell; Contrast Media; Female; Humans; Iohexol; Kidney Dis

2014
First experience with single-source, dual-energy CCTA for monochromatic stent imaging.
    European heart journal. Cardiovascular Imaging, 2015, Volume: 16, Issue:5

    Topics: Adult; Aged; Aged, 80 and over; Artifacts; Cardiac-Gated Imaging Techniques; Contrast Media; Coronar

2015
Coronary computed tomography angiography predicts subsequent cardiac outcome events: results of the Visipaque CCTA registry study.
    Coronary artery disease, 2015, Volume: 26, Issue:4

    Topics: Contrast Media; Coronary Angiography; Coronary Artery Disease; Coronary Stenosis; False Negative Rea

2015
CT texture analysis can help differentiate between malignant and benign lymph nodes in the mediastinum in patients suspected for lung cancer.
    Acta radiologica (Stockholm, Sweden : 1987), 2016, Volume: 57, Issue:6

    Topics: Adult; Carcinoma, Non-Small-Cell Lung; Contrast Media; Denmark; Diagnosis, Differential; Female; Hum

2016
Myocardial Fractional Flow Reserve Measurement Using Contrast Media as a First-Line Assessment of Coronary Lesions in Current Practice.
    The Canadian journal of cardiology, 2016, Volume: 32, Issue:6

    Topics: Adenosine; Aged; Body Mass Index; Contrast Media; Coronary Angiography; Coronary Stenosis; Female; F

2016
Role of Neutrophil Gelatinase-associated Lipocalin in the Detection of Contrast-induced Nephropathy in Patients Undergoing a Coronary Angiography.
    Revista espanola de cardiologia (English ed.), 2016, Volume: 69, Issue:5

    Topics: Acute Coronary Syndrome; Acute Kidney Injury; Aged; Contrast Media; Coronary Angiography; Creatinine

2016
Whole-body diffusion-weighted magnetic resonance imaging in the diagnosis of recurrent ovarian cancer: a clinical feasibility study.
    The British journal of radiology, 2016, Volume: 89, Issue:1067

    Topics: Adult; Aged; Aged, 80 and over; Biopsy; Contrast Media; Diffusion Magnetic Resonance Imaging; Feasib

2016
Diagnostic Accuracy of Noninvasive 64-row Computed Tomographic Coronary Angiography (CCTA) Compared with Myocardial Perfusion Imaging (MPI): The PICTURE Study, A Prospective Multicenter Trial.
    Academic radiology, 2017, Volume: 24, Issue:1

    Topics: Angina Pectoris; Computed Tomography Angiography; Contrast Media; Coronary Angiography; Coronary Art

2017
Subjective and objective image differences in pediatric computed tomography cardiac angiography using lower iodine concentration.
    Pediatric radiology, 2017, Volume: 47, Issue:6

    Topics: Artifacts; Computed Tomography Angiography; Contrast Media; Coronary Angiography; Feasibility Studie

2017
Comprehensive assessment of myocardial perfusion defects, regional wall motion, and left ventricular function by using 64-section multidetector CT.
    Radiology, 2008, Volume: 248, Issue:2

    Topics: Biomarkers; Chi-Square Distribution; Contrast Media; Echocardiography; Female; Humans; Male; Middle

2008
Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT.
    Radiology, 2008, Volume: 249, Issue:2

    Topics: Adult; Aged; Aged, 80 and over; Aortic Aneurysm, Abdominal; Contrast Media; Female; Humans; Male; Mi

2008
Primary three-dimensional analysis with perspective-filet view versus primary two-dimensional analysis: evaluation of lesion detection by inexperienced readers at computed tomographic colonography in symptomatic patients.
    Acta radiologica (Stockholm, Sweden : 1987), 2009, Volume: 50, Issue:3

    Topics: Adenocarcinoma; Adenoma; Aged; Aged, 80 and over; Clinical Competence; Colonic Polyps; Colonography,

2009
[Cardiac imaging].
    Der Radiologe, 2009, Volume: 49, Issue:4

    Topics: Biomarkers; Chi-Square Distribution; Contrast Media; Echocardiography; Female; Humans; Male; Middle

2009
Comparison of CT colonography vs. conventional colonoscopy in mapping the segmental location of colon cancer before surgery.
    Abdominal imaging, 2010, Volume: 35, Issue:5

    Topics: Colonography, Computed Tomographic; Colonoscopy; Colorectal Neoplasms; Contrast Media; Female; Human

2010
Comparison of cardiac computed tomographic angiography to transesophageal echocardiography for evaluation of patients with native valvular heart disease.
    The American journal of cardiology, 2009, Nov-15, Volume: 104, Issue:10

    Topics: Contrast Media; Coronary Angiography; Echocardiography, Transesophageal; Electrocardiography; Female

2009
The value of preprocedure computed tomography for planning insertion of inferior vena cava filters.
    Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes, 2010, Volume: 61, Issue:4

    Topics: Adolescent; Adult; Aged; Aged, 80 and over; Contrast Media; Female; Humans; Male; Middle Aged; Preop

2010
Split-bolus MDCT urography: Upper tract opacification and performance for upper tract tumors in patients with hematuria.
    AJR. American journal of roentgenology, 2010, Volume: 194, Issue:2

    Topics: Adolescent; Adult; Aged; Aged, 80 and over; Contrast Media; Female; Hematuria; Humans; Male; Middle

2010
Mitral valve prolapse: evaluation with ECG-gated cardiac CT angiography.
    AJR. American journal of roentgenology, 2010, Volume: 194, Issue:3

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Coronary Angiography; Echocardiography; Electrocardi

2010
Computed analysis of three-dimensional cone-beam computed tomography angiography for determination of tumor-feeding vessels during chemoembolization of liver tumor: a pilot study.
    Cardiovascular and interventional radiology, 2010, Volume: 33, Issue:6

    Topics: Adult; Aged; Angiography; Carcinoma, Hepatocellular; Chemoembolization, Therapeutic; Cone-Beam Compu

2010
Findings of cecal volvulus at CT.
    Radiology, 2010, Volume: 256, Issue:1

    Topics: Adult; Aged; Aged, 80 and over; Cecum; Contrast Media; Diatrizoate Meglumine; Female; Humans; Intest

2010
Unenhanced versus multiphase MDCT in patients with hematuria, flank pain, and a negative ultrasound.
    European journal of radiology, 2012, Volume: 81, Issue:3

    Topics: Contrast Media; Female; Flank Pain; Hematuria; Humans; Logistic Models; Male; Middle Aged; Radiograp

2012
The coffee bean sign in sigmoid volvulus.
    Radiology, 2011, Volume: 258, Issue:2

    Topics: Cecum; Contrast Media; Diagnosis, Differential; Diatrizoate Meglumine; Humans; Intestinal Volvulus;

2011
Recognition of iodixanol by dendritic cells increases the cellular response in delayed allergic reactions to contrast media.
    Clinical and experimental allergy : journal of the British Society for Allergy and Clinical Immunology, 2011, Volume: 41, Issue:5

    Topics: Aged, 80 and over; Cell Proliferation; Contrast Media; Cytokines; Dendritic Cells; Humans; Hypersens

2011
CT angiography for evaluation of cerebral vasospasm following acute subarachnoid haemorrhage.
    Neuroradiology, 2012, Volume: 54, Issue:3

    Topics: Adult; Aged; Angiography, Digital Subtraction; Cerebral Angiography; Chi-Square Distribution; Contra

2012
[Diagnostic accuracy of contrast-enhanced 64-row MSCT coronary angiography in patients with severe coronary calcification in the clinical routine].
    RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 2011, Volume: 183, Issue:12

    Topics: Aged; Aged, 80 and over; Artifacts; Calcinosis; Cardiac-Gated Imaging Techniques; Contrast Media; Co

2011
Upper urinary tract biopsy: an old device for a new approach.
    La Radiologia medica, 2012, Volume: 117, Issue:7

    Topics: Adult; Aged; Aged, 80 and over; Biopsy; Contrast Media; Feasibility Studies; Female; Humans; Male; M

2012
Cardioembolic stroke: dual-energy cardiac CT for differentiation of left atrial appendage thrombus and circulatory stasis.
    Radiology, 2012, Volume: 263, Issue:3

    Topics: Adult; Aged; Aged, 80 and over; Atrial Appendage; Case-Control Studies; Chi-Square Distribution; Con

2012
Detection of urothelial tumors: comparison of urothelial phase with excretory phase CT urography--a prospective study.
    Radiology, 2012, Volume: 264, Issue:1

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Diuretics; Female; Humans; Logistic Models; Male; Mi

2012
Comparing the diagnostic performance of MRI versus CT in the evaluation of acute nontraumatic abdominal pain during pregnancy.
    Emergency radiology, 2012, Volume: 19, Issue:6

    Topics: Abdominal Pain; Adult; Contrast Media; Diagnosis, Differential; Diatrizoate Meglumine; Female; Human

2012
Comparison of iodinated contrast media for the assessment of atherosclerotic plaque attenuation values by CT coronary angiography: observations in an ex vivo model.
    The British journal of radiology, 2013, Volume: 86, Issue:1021

    Topics: Contrast Media; Coronary Angiography; Coronary Artery Disease; Dose-Response Relationship, Drug; Fem

2013
Resting cardiac 64-MDCT does not reliably detect myocardial ischemia identified by radionuclide imaging.
    AJR. American journal of roentgenology, 2013, Volume: 200, Issue:2

    Topics: Adolescent; Adult; Aged; Cardiac-Gated Imaging Techniques; Contrast Media; Coronary Angiography; Fem

2013
Multislice computed tomography coronary angiography at a local hospital: Pitfalls and potential.
    Acta radiologica (Stockholm, Sweden : 1987), 2006, Volume: 47, Issue:7

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Coronary Angiography; Coronary Stenosis; Female; Hos

2006
Superior sensitivity of angiographic detection of arteriovenous fistula after biopsy in a renal allograft with CO2 compared with iodinated contrast medium.
    Journal of vascular and interventional radiology : JVIR, 2006, Volume: 17, Issue:12

    Topics: Adult; Angiography, Digital Subtraction; Arteriovenous Fistula; Biopsy; Carbon Dioxide; Contrast Med

2006
Computerized analysis of digital subtraction angiography: a tool for quantitative in-vivo vascular imaging.
    Journal of digital imaging, 2008, Volume: 21, Issue:4

    Topics: Angiography, Digital Subtraction; Animals; Contrast Media; Disease Models, Animal; False Negative Re

2008
Multislice CT angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling.
    Neuroradiology, 2007, Volume: 49, Issue:12

    Topics: Adult; Aged; Aneurysm, Ruptured; Angiography, Digital Subtraction; Cerebral Angiography; Contrast Me

2007
Contrast enhancement hyperdensity after endovascular coiling of intracranial aneurysms.
    AJNR. American journal of neuroradiology, 2008, Volume: 29, Issue:3

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Embolization, Therapeutic; Female; Humans; Image Enh

2008
Can contrast-enhanced ultrasonography replace multidetector-computed tomography in the detection of liver metastases from colorectal cancer?
    European journal of radiology, 2009, Volume: 69, Issue:2

    Topics: Adult; Aged; Aged, 80 and over; Colorectal Neoplasms; Contrast Media; Humans; Liver Neoplasms; Middl

2009
Coronary 64-slice CT angiography predicts outcome in patients with known or suspected coronary artery disease.
    European radiology, 2008, Volume: 18, Issue:6

    Topics: Chi-Square Distribution; Contrast Media; Coronary Angiography; Coronary Disease; Female; Humans; Mal

2008
Vascular renal anatomy and the ureteropelvic junction: preoperative multidetector CT scanning with split-bolus injection as a predictor of laparoscopic findings.
    Journal of endourology, 2008, Volume: 22, Issue:1

    Topics: Adolescent; Adult; Aged; Contrast Media; Humans; Kidney Pelvis; Laparoscopy; Middle Aged; Renal Arte

2008
Absolute coronary artery calcium scores are superior to MESA percentile rank in predicting obstructive coronary artery disease.
    The international journal of cardiovascular imaging, 2008, Volume: 24, Issue:7

    Topics: Area Under Curve; Calcinosis; Cohort Studies; Contrast Media; Coronary Angiography; Coronary Artery

2008
Nonatherosclerotic cardiovascular findings on MDCT coronary angiography: a selection of abnormalities.
    AJR. American journal of roentgenology, 2008, Volume: 190, Issue:4

    Topics: Adult; Aged; Contrast Media; Coronary Aneurysm; Coronary Angiography; Coronary Artery Disease; Coron

2008
Liver-specific contrast media for magnetic resonance imaging and computed tomography scanning: importance of contrast media for tumor detection in an experimental liver tumor model.
    Academic radiology, 1996, Volume: 3 Suppl 2

    Topics: Animals; Contrast Media; Ferric Compounds; Image Enhancement; Iron; Liver; Liver Neoplasms, Experime

1996
Iodixanol and the heart.
    Academic radiology, 1996, Volume: 3 Suppl 2

    Topics: Adult; Aged; Aged, 80 and over; Angiocardiography; Contrast Media; Electrocardiography; Female; Hear

1996
On-line dialysis and quantitative high-performance liquid chromatography analysis of iodixanol in human, rat and monkey plasma.
    Journal of chromatography. B, Biomedical sciences and applications, 2000, Nov-10, Volume: 749, Issue:1

    Topics: Animals; Chromatography, High Pressure Liquid; Contrast Media; Dialysis; Haplorhini; Humans; Rats; R

2000