interleukin-8 and Chagas-Cardiomyopathy

interleukin-8 has been researched along with Chagas-Cardiomyopathy* in 2 studies

Other Studies

2 other study(ies) available for interleukin-8 and Chagas-Cardiomyopathy

ArticleYear
Genetic variants in the chemokines and chemokine receptors in Chagas disease.
    Human immunology, 2012, Volume: 73, Issue:8

    Clinical symptoms of Chagas' disease occur in 30% of the individuals infected with Trypanosoma cruzi and are characterised by heart inflammation and dysfunction. Chemokines and chemokine receptors control the migration of leukocytes during the inflammatory process and are involved in the modulation of Th1 or Th2 responses. To determine their influence, we investigated the possible role of CCL5/RANTES and CXCL8/IL8 chemokines, and CCR2 and CCR5 chemokines receptors cluster gene polymorphisms with the development of chagasic cardiomyopathy. Our study included 260 Chagas seropositive individuals (asymptomatic, n=130; cardiomyopathic, n=130) from an endemic area of Colombia. Genotyping was performed by polymerase chain reaction restriction fragment length polymorphism (PCR-RFLP) and TaqMan SNP genotyping assay. We found statistically significant differences in the distribution of the CCR5 human haplogroup (HH)-A (p=0.027; OR=3.78, 95% CI=1.04-13.72). Moreover, we found that the CCR5-2733 G and CCR5-2554 T alleles are associated, respectively, with a reduced risk of susceptibility and severity to develop chagasic cardiomyopathy. No other associations were found to be significant for the other polymorphisms analysed in the CCR5, CCR2, CCL5/RANTES and CXCL8/IL8 genes. Our data suggest that the analysed chemokines and chemokine receptor genetic variants have a weak but important association with the development of chagasic cardiomyopathy in the population under study.

    Topics: Adult; Alleles; Chagas Cardiomyopathy; Chemokine CCL5; Female; Gene Frequency; Genetic Predisposition to Disease; Humans; Interleukin-8; Male; Middle Aged; Polymorphism, Restriction Fragment Length; Polymorphism, Single Nucleotide; Receptors, CCR2; Receptors, CCR5; Trypanosoma cruzi

2012
Hemodynamic performance and inflammatory response during the use of VAD-InCor as a bridge to transplant.
    Arquivos brasileiros de cardiologia, 2008, Volume: 91, Issue:5

    Cardiac transplantation faces the serious problem of lack of donors and it is estimated that 20 to 40% of the patients die while waiting for heart transplantation. For these patients, the use of mechanical circulatory assist devices is the only choice of survival while waiting for a donor. In Brazil, the experience with mechanical circulatory support is limited and there is no regular program regarding the use of these devices as a bridge to heart transplantation.. To evaluate the hemodynamic performance and the systemic inflammatory response during the clinical use of the InCor-type ventricular assist device (VAD-InCor) as a bridge to heart transplantation.. Between October 2003 and April 2006, 11 patients in the waiting list for heart transplantation presented hemodynamic deterioration due to refractory cardiogenic shock. Seven of these patients were submitted to VAD-InCor implantation for left ventricular assistance. The etiologic diagnosis was Chagas' disease in 5 patients and idiopathic dilated cardiomyopathy in 2.. The duration of left ventricular assistance ranged from 14 to 42 days (mean 26.2 days). During this period, the hemodynamic performance of the DAV-InCor was adequate to support a normal hemodynamic state. There was normalization of central venous oxygen saturation and serum lactate. Two patients were submitted to heart transplantation, while the other 5 patients died under assistance due to infection and multiple organ failure.. The performance of the VAD-InCor, in the hemodynamic behavior of the studied patients, was adequate for the maintenance of a satisfactory circulatory state during the studied period. There was improvement in the tissue perfusion parameters and maintenance of systemic inflammatory response signs. There was a high incidence of complications; however, complications related to the device, which could compromise the safety of its use, were not demonstrated.

    Topics: Adult; Biomarkers; C-Reactive Protein; Cardiomyopathy, Dilated; Chagas Cardiomyopathy; Female; Heart Transplantation; Heart-Assist Devices; Hemodynamics; Humans; Inflammation Mediators; Interleukin-6; Interleukin-8; Male; Middle Aged; Statistics, Nonparametric; Tumor Necrosis Factor-alpha; Waiting Lists

2008