indigo-carmine and Intestinal-Polyps

indigo-carmine has been researched along with Intestinal-Polyps* in 6 studies

Reviews

2 review(s) available for indigo-carmine and Intestinal-Polyps

ArticleYear
Chromoscopy versus conventional endoscopy for the detection of polyps in the colon and rectum.
    The Cochrane database of systematic reviews, 2016, Apr-07, Volume: 4

    Although conventional colonoscopy is the most accurate test available for the investigation of the colorectum for polyps, data exist that raise concerns about its sensitivity. Chromoscopy (spraying dye onto the surface of the colon to make polyps more visible) may be one way of enhancing the ability of colonoscopy to detect polyps, particularly diminutive flat lesions, which otherwise may be difficult to detect.. To determine whether the use of chromoscopy enhances the detection of polyps and neoplasia during endoscopic examination of the colon and rectum.. We searched the following databases: Cochrane Colorectal Cancer Group Specialised Register (October 2015), Cochrane Central Register of Controlled Trials (CENTRAL) (Cochrane Library; Issue 10, 2015), MEDLINE (January 1950 to October 2015), EMBASE (January 1974 to October 2015), and ClinicalTrials.gov and World Health Organization International Clinical Trials Registry Platform (both November 2015). We also handsearched abstracts from relevant meetings from 1980 to 2015. Search terms included 'randomised trials' containing combinations of the following: 'chromoscopy' 'colonoscopy' 'dye-spray' 'chromo-endoscopy' 'indigo-carmine' 'magnifying endoscopy'.. We included all prospective randomised trials comparing chromoscopic with conventional endoscopic examination of the whole of the colon and rectum. We excluded studies of people with inflammatory bowel disease or polyposis syndromes and any studies that combined chromoscopy with additional interventions (cap assistance, water-perfused, etc.).. Two review authors independently assessed the methodological quality of potentially eligible trials, and two review authors independently extracted data from the included trials. Outcome measures included the detection of polyps (neoplastic and non-neoplastic), the detection of diminutive lesions, the number of participants with multiple neoplastic lesions, and the extubation time.. We included seven trials (2727 participants) in this update. Five trials were of sufficiently similar design to allow for pooled results. Two trials differed substantially in design and were included in a subgroup analysis. All the trials had some methodological drawbacks. However, combining the results showed a significant difference in favour of chromoscopy for all detection outcomes. In particular, chromoscopy was likely to yield significantly more people with at least one neoplastic lesion (odds ratio (OR) 1.53, 95% confidence interval (CI) 1.31 to 1.79; 7 trials; 2727 participants), and at least one diminutive neoplastic lesion (OR 1.51, 95% CI 1.19 to 1.92; 4 trials; 1757 participants). Significantly more people with three or more neoplastic lesions were also detected, but only when studies that used high-definition colonoscopy in the control group were excluded (OR 4.63, 95% CI 1.99 to 10.80; 2 trials; 519 participants). None of the included studies reported any adverse events related to the use of the contrast dye.. There is strong evidence that chromoscopy enhances the detection of neoplasia in the colon and rectum. People with neoplastic polyps, particularly those with multiple polyps, are at increased risk of developing colorectal cancer. Such lesions, which presumably would be missed with conventional colonoscopy, could contribute to the interval cancer numbers on any surveillance programme.

    Topics: Colonic Polyps; Colonoscopy; Humans; Indicators and Reagents; Indigo Carmine; Intestinal Polyps; Precancerous Conditions; Randomized Controlled Trials as Topic; Rectal Diseases

2016
Chromoscopy versus conventional endoscopy for the detection of polyps in the colon and rectum.
    The Cochrane database of systematic reviews, 2010, Oct-06, Issue:10

    Although conventional colonoscopy is the most sensitive test available for the investigation of the colorectum for polyps, there are data that raise concerns about its sensitivity. Chromoscopy may be one way of enhancing the ability for colonoscopy to detect polyps particularly diminutive flat lesions that may be otherwise difficult to detect.. To determine whether the use of chromoscopy enhances detection of polyps and neoplasia during endoscopic examination of the colon and rectum.. MEDLINE, EMBASE and the Cochrane Library databases were searched (April 2010) along with a hand search of abstracts from relevant meetings. Search terms included randomised trials containing combinations of the following: 'chromoscopy' 'colonoscopy' 'dye-spray' 'chromo-endoscopy' 'indigo-carmine' 'magnifying endoscopy'.. All prospective randomised trials comparing chromoscopic with conventional endoscopic examination of the lower gastrointestinal tract were included. Patients with inflammatory bowel disease or polyposis syndromes were excluded.. Two reviewers assessed the methodological quality of potentially eligible trials and independently extracted data from the included trials. Outcome measures included the detection of polyps (neoplastic and non-neoplastic), the detection of diminutive lesions, the number of patients with multiple neoplastic lesions and the extubation time.. Five trials were included in this update, and although there were some methodological drawbacks and differences in study design, combining the results showed a significant difference in favour of chromoscopy for all detection outcomes. In particular, chromoscopy is likely to yield significantly more patients with at least one neoplastic lesion (OR 1.67 (CI 1.29-2.15)) and significantly more patients with three or more neoplastic lesions (OR 2.55 (CI 1.49-4.36)). Not surprisingly the withdrawal times were significantly slower for the chromoscopy group.. There appears to be strong evidence that chromoscopy enhances the detection of neoplasia in the colon and rectum. Patients with neoplastic polyps, particularly those with multiple polyps, are at increased risk of developing colorectal cancer. Such lesions, which presumably would be missed with conventional colonoscopy, could contribute to the interval cancer numbers on any surveillance programme.

    Topics: Colonic Polyps; Colonoscopy; Humans; Indicators and Reagents; Indigo Carmine; Intestinal Polyps; Precancerous Conditions; Randomized Controlled Trials as Topic; Rectal Diseases

2010

Trials

3 trial(s) available for indigo-carmine and Intestinal-Polyps

ArticleYear
Endoscopic mucosal resection in high- and low-volume centers: a prospective multicentric study.
    Surgical endoscopy, 2013, Volume: 27, Issue:10

    Endoscopic mucosal resection (EMR) is an effective therapeutic technique well-standardized worldwide for the treatment of gastrointestinal neoplasm limited to the mucosal layer. To date, no study has compared technical and clinical differences based on the number of EMRs performed per year. This study aimed to compare EMR technical success, complications, and clinical outcome between low-volume centers (LVCs) and high-volume centers (HVCs). A total of nine endoscopic centers were included in the study.. This prospective study investigated consecutive patients with sessile polyps or flat colorectal lesions 1 cm or larger referred for EMR.. A total of 427 lesions were resected in 384 patients at nine endoscopic centers. Males accounted for 60.4% and females for 39.6% of the patients. Most of the EMRs (84.8%) were performed in HVCs and only 15.2% in LVCs. All the lesions were resected in only one session. Argon plasma coagulation was performed on the margins of piecemeal resection in 15.7% of the patients in HVCs only. Complete excision was achieved for 98.6% of the lesions in HVCs and 98.8% of the lesions in LVCs. The complication rate was 4.4% in HVCs and 4.6% in LVCs (p = 0.94). Delayed bleeding occurred in 2.5% of the HVC cases and 3.1% of the LVC cases. Perforation occurred in 1.9% of the HVC cases and 1.5% of the LVC cases (p = 1.00). Recurrences were experienced with 15% of the lesions: 15.5% in HVCs and 14% in LVCs (p = 0.79).. The study showed that EMR can be performed also in LVC.

    Topics: Adenocarcinoma; Adenoma; Aged; Colonic Polyps; Colonoscopy; Colorectal Neoplasms; Coloring Agents; Female; Gastrointestinal Hemorrhage; Humans; Indigo Carmine; Intestinal Mucosa; Intestinal Polyps; Italy; Lymphoma, B-Cell, Marginal Zone; Male; Middle Aged; Neoplasm Recurrence, Local; Postoperative Hemorrhage; Prospective Studies; Surgicenters; Workload

2013
Computerized virtual chromoendoscopy versus indigo carmine chromoendoscopy combined with magnification for diagnosis of small colorectal lesions: a randomized and prospective study.
    European journal of gastroenterology & hepatology, 2010, Volume: 22, Issue:11

    Magnifying colonoscopy with indigo carmine dye and the analysis of the capillary and the pit patterns by computed virtual chromoendoscopy (Fujinon Intelligent Color Enhancement, FICE) with magnification are effective for the differential diagnosis of neoplastic and non-neoplastic lesions. This study aimed to compare the accuracy of virtual and real chromoendoscopy in differentiating neoplastic and non-neoplastic colorectal lesions.. A prospective randomized trial of magnification colonoscopy with targeted FICE (Group I - 72 patients/111 lesions) versus magnification colonoscopy with targeted indigo carmine dye (Group II - 72 patients/137 lesions) was performed in consecutive patients with lesions 1 cm or less. Histopathology of the specimens was regarded as the gold standard.. In group I, 86 (77.5%) lesions showed an intense vascular pattern (positive capillary meshwork), of which 80 (93%) were histologically confirmed as adenomas. From 25 lesions with negative capillary meshwork, 23 (92%) were non-neoplastic. Sensitivity, specificity, accuracy, positive and negative predictive values of the capillary meshwork for the differential diagnosis of these lesions was 97.8, 79.3, 92.8, 93 and 92%, respectively. The same parameters for pit pattern analysis by FICE were 92.7, 82.3, 90.1, 93.8 and 80%, respectively. Indigo carmine magnified chromoscopy showed sensitivity, specificity, accuracy, positive and negative predictive values of 97, 88.9, 94.9, 96.1 and 91.4%, respectively in the discrimination between neoplastic and non-neoplastic lesions.. Magnified virtual chromoendoscopy is as accurate as indigo carmine magnified chromoendoscopy in distinguishing between neoplastic from non-neoplastic small colorectal lesions.

    Topics: Adenoma; Brazil; Chi-Square Distribution; Colonic Polyps; Colorectal Neoplasms; Coloring Agents; Diagnosis, Differential; Endoscopy, Gastrointestinal; Female; Humans; Image Enhancement; Indigo Carmine; Intestinal Polyps; Male; Middle Aged; Predictive Value of Tests; Prospective Studies; Rectum; Sensitivity and Specificity

2010
Further validation of magnifying chromocolonoscopy for differentiating colorectal neoplastic polyps in a health screening center.
    Journal of gastroenterology and hepatology, 2007, Volume: 22, Issue:11

    The accuracy of conventional colonoscopy to differentiate neoplastic and non-neoplastic polyps is limited, justifying a biopsy for histologic analysis. Magnifying chromocolonoscopy has emerged as the best tool available for differentiating adenomatous and hyperplastic polyps during colonoscopy; however, magnifying endoscopes are rarely used in endoscopy units. This study aimed to further validate the effectiveness of magnifying chromocolonoscopy in the diagnosis of neoplastic colorectal polyps in a screening center.. Five hundred average-risk subjects were randomly divided into two groups: a magnifying chromocolonoscopy group and a conventional chromocolonoscopy group, each of 250 subjects. Lesions were analyzed according to Kudo's classification of pit pattern (types I-V) and additionally subdivided into non-neoplastic (types I-II) and neoplastic (types III-V). Lesions judged as neoplastic were resected and those judged as non-neoplastic were left in situ. Only lesions < or =10 mm were included in the study. Resected lesions were analyzed with histopathological examination.. The overall accuracy of magnifying chromocolonoscopy for differentiating neoplastic lesions (95%, 135 of 142), was significantly higher than that of conventional chromocolonoscopy (84%, 102 of 122; P < 0.01). The accuracy of magnifying chromocolonoscopy for differentiating neoplastic lesions < or =5 mm was 94% (135 of 142), whereas that of conventional chromocolonoscopy was only 78% (69 of 89; P < 0.001). Results were not affected by the macroscopic types.. Magnifying chromocolonoscopy is superior to conventional chromocolonoscopy for the diagnosis of colorectal neoplastic lesions in the setting of a health testing center.

    Topics: Adenomatous Polyps; Colonic Polyps; Colonoscopy; Colorectal Neoplasms; Coloring Agents; Diagnosis, Differential; Female; Humans; Hyperplasia; Indigo Carmine; Intestinal Polyps; Male; Mass Screening; Middle Aged; Predictive Value of Tests; Prospective Studies; Rectal Diseases; Reproducibility of Results

2007

Other Studies

1 other study(ies) available for indigo-carmine and Intestinal-Polyps

ArticleYear
Magnifying chromoendoscopy: effective diagnostic tool for screening colonoscopy.
    Journal of gastroenterology and hepatology, 2007, Volume: 22, Issue:11

    Topics: Adenomatous Polyps; Colonic Polyps; Colonoscopy; Colorectal Neoplasms; Coloring Agents; Diagnosis, Differential; Humans; Hyperplasia; Indigo Carmine; Intestinal Polyps; Mass Screening; Predictive Value of Tests; Rectal Diseases; Reproducibility of Results; Research Design

2007