helium has been researched along with Pulmonary Embolism in 21 studies
Timeframe | Studies, this research(%) | All Research% |
---|---|---|
pre-1990 | 6 (28.57) | 18.7374 |
1990's | 2 (9.52) | 18.2507 |
2000's | 11 (52.38) | 29.6817 |
2010's | 2 (9.52) | 24.3611 |
2020's | 0 (0.00) | 2.80 |
Authors | Studies |
---|---|
Albert, MS; Gounis, MJ; Reno, AL; Roche, JP; Walvick, RP | 1 |
Bauman, G; de Oliveira, A; Friedrich, J; Puderbach, M; Rivoire, J; Scholz, A; Schreiber, LM; Semmler, W; Terekhov, M | 1 |
Dimitrov, IE; Gentile, TR; Hansen-Flaschen, J; Jones, G; Leigh, JS; Lipson, DA; Palevsky, HI; Rizi, RR; Roberts, DA; Schnall, M; Thompson, A | 1 |
BOGDONOFF, ML | 1 |
Baumgardner, JE; Edvinsson, JM; Guan, L; Ishii, M; Itkin, M; Jalali, A; Lipson, DA; Rizi, RR | 1 |
Blümler, P; Eberle, B; Gast, KK; Kauczor, HU; Lehmann, F; Markstaller, K; Schmiedeskamp, J; Schreiber, WG | 1 |
Kadlecek, S; Rizi, RR | 1 |
Bae, KT; Conradi, MS; Hong, C; Leawoods, JC; Leyendecker, JR; Pilgram, TK; Woodard, PK; Yablonskiy, DA; Zheng, J | 1 |
Altes, TA; Brookeman, JR; Hagspiel, KD; Mai, VM; Munger, TM | 1 |
Ho, HS; Mathiesen, KA; Roberts, MW; Wolfe, BM | 1 |
Albert, T; Berthezène, Y; Bourgeois, M; Briguet, A; Canet, E; Crémillieux, Y; Heil, W; Humblot, H; Viallon, M | 1 |
Frazer, D; Hlastala, MP; Tsang, JY | 1 |
Berthezène, Y; Bourgeois, M; Briguet, A; Callot, V; Crémillieux, Y; Décorps, M; Humblot, H; Viallon, M; Wiart, M | 1 |
Berthezène, Y; Briguet, A; Brochot, J; Callot, V; Canet, E; Crémillieux, Y; Humblot, H; Tournier, H; Viallon, M | 1 |
Briguet, A; Brochot, J; Callot, V; Canet, E; Crémillieux, Y; Humblot, H; Tournier, H; Viallon, M | 1 |
Conradi, MS; Gropler, RJ; Laub, G; Leawoods, JC; Nolte, M; Woodard, PK; Yablonskiy, DA; Zheng, J | 1 |
Bernards, JA; Kreuzer, AF; Verstappen, FT | 1 |
Chang, HK; Delaunois, L; Jasper, N; Martin, RR; Sergysels, R | 1 |
Balouet, G; Barthelemy, L; Le Chuiton, J; Leroy, JP; Michaud, A; Parc, J | 1 |
Alkalay, I; Khan, MA; Stein, M; Suetsugu, S | 1 |
Behnke, AR | 1 |
1 review(s) available for helium and Pulmonary Embolism
Article | Year |
---|---|
The Harry G. Armstrong Lecture. Decompression sickness: advances and interpretations.
Topics: Aerospace Medicine; Age Factors; Animals; Biological Transport; Blood Platelets; Blood Pressure; Body Weight; Bone Diseases; Decompression Sickness; Diving; Embolism, Air; Embolism, Fat; Fatigue; Heart; Helium; Humans; Hyperbaric Oxygenation; Lipid Metabolism; Nitrogen; Oxygen Inhalation Therapy; Pain; Pulmonary Circulation; Pulmonary Embolism; Respiration; Submarine Medicine | 1971 |
20 other study(ies) available for helium and Pulmonary Embolism
Article | Year |
---|---|
Evaluation of oxygen sensitivity of hyperpolarized helium imaging for the detection of pulmonary ischemia.
Topics: Animals; Helium; Image Processing, Computer-Assisted; Ischemia; Lung; Lung Diseases; Magnetic Resonance Imaging; Oxygen; Pulmonary Artery; Pulmonary Embolism; Rats; Rats, Sprague-Dawley | 2016 |
Lung ventilation- and perfusion-weighted Fourier decomposition magnetic resonance imaging: in vivo validation with hyperpolarized 3He and dynamic contrast-enhanced MRI.
Topics: Animals; Contrast Media; Fourier Analysis; Gadolinium DTPA; Helium; Isotopes; Lung; Magnetic Resonance Angiography; Magnetic Resonance Imaging; Male; Pulmonary Embolism; Pulmonary Ventilation; Sus scrofa; Ventilation-Perfusion Ratio | 2013 |
Pulmonary ventilation and perfusion scanning using hyperpolarized helium-3 MRI and arterial spin tagging in healthy normal subjects and in pulmonary embolism and orthotopic lung transplant patients.
Topics: Helium; Humans; Isotopes; Lung Transplantation; Magnetic Resonance Imaging; Pulmonary Embolism; Pulmonary Emphysema; Ventilation-Perfusion Ratio | 2002 |
COMPARATIVE STUDY OF PATIENTS WITH PNEUMONIA, ATELECTASIS, AND LUNG INFARCTION FOLLOWING INHALATION OF VARIOUS GAS MIXTURES.
Topics: Bronchoscopy; Cough; Diagnosis, Differential; Fever; Helium; Humans; Infarction; Oxygen; Pneumonia; Pulmonary Atelectasis; Pulmonary Embolism; Radiography, Thoracic; Respiration | 1964 |
Detection of simulated pulmonary embolism in a porcine model using hyperpolarized 3He MRI.
Topics: Animals; Disease Models, Animal; Helium; Isotopes; Magnetic Resonance Imaging; Pulmonary Embolism; Swine | 2004 |
[A software program for quantitative analysis of alveolar oxygen partial pressure (p(A)O(2)) with oxygen-sensitive (3)He-MRI].
Topics: Adult; Chronic Disease; Helium; Humans; Isotopes; Lung; Lung Diseases; Lung Diseases, Obstructive; Magnetic Resonance Imaging; Middle Aged; Models, Theoretical; Oxygen; Partial Pressure; Pulmonary Alveoli; Pulmonary Embolism; Respiration; Software | 2004 |
New diagnostic tests for pulmonary emboli.
Topics: Contrast Media; Gadolinium DTPA; Helium; Humans; Image Enhancement; Isotopes; Magnetic Resonance Angiography; Magnetic Resonance Imaging; Pulmonary Embolism | 2005 |
Feasibility of combining MR perfusion, angiography, and 3He ventilation imaging for evaluation of lung function in a porcine model.
Topics: Administration, Inhalation; Airway Obstruction; Animals; Contrast Media; Disease Models, Animal; Feasibility Studies; Gadolinium DTPA; Helium; Image Processing, Computer-Assisted; Imaging, Three-Dimensional; Isotopes; Magnetic Resonance Angiography; Magnetic Resonance Imaging; Observer Variation; Pulmonary Embolism; Reproducibility of Results; Sensitivity and Specificity; Swine | 2005 |
Pulmonary embolism: comprehensive evaluation with MR ventilation and perfusion scanning with hyperpolarized helium-3, arterial spin tagging, and contrast-enhanced MRA.
Topics: Animals; Disease Models, Animal; Helium; Isotopes; Lung; Magnetic Resonance Angiography; Magnetic Resonance Imaging; Pulmonary Embolism; Rabbits | 2005 |
Cardiopulmonary responses to intravenous infusion of soluble and relatively insoluble gases.
Topics: Animals; Argon; Carbon Dioxide; Embolism, Air; Female; Gases; Helium; Hemodynamics; Infusions, Intravenous; Male; Nitrogen; Nitrous Oxide; Pneumoperitoneum, Artificial; Pulmonary Embolism; Risk Factors; Swine | 1997 |
A combined 1H perfusion/3He ventilation NMR study in rat lungs.
Topics: Animals; Helium; Hydrogen; Isotopes; Magnetic Resonance Imaging; Male; Pulmonary Circulation; Pulmonary Embolism; Pulmonary Ventilation; Rats; Rats, Sprague-Dawley | 1999 |
Ventilation heterogeneity does not change following pulmonary microembolism.
Topics: Animals; Blood Gas Analysis; Blood Pressure; Carbon Dioxide; Dogs; Helium; Hemodynamics; Lung; Lung Volume Measurements; Oxygen; Partial Pressure; Pulmonary Embolism; Pulmonary Gas Exchange; Pulmonary Ventilation; Respiratory Mechanics | 2000 |
Laser-polarized (3)He as a probe for dynamic regional measurements of lung perfusion and ventilation using magnetic resonance imaging.
Topics: Animals; Contrast Media; Ferric Compounds; Helium; Isotopes; Magnetic Resonance Imaging; Male; Pulmonary Circulation; Pulmonary Embolism; Pulmonary Ventilation; Rats; Rats, Sprague-Dawley | 2000 |
Vascular and perfusion imaging using encapsulated laser-polarized helium.
Topics: Animals; Disease Models, Animal; Helium; Lasers; Lung; Magnetic Resonance Spectroscopy; Male; Pulmonary Circulation; Pulmonary Embolism; Pulmonary Ventilation; Rats; Rats, Sprague-Dawley; Ventilation-Perfusion Ratio; Xenon | 2001 |
MR perfusion imaging using encapsulated laser-polarized 3He.
Topics: Animals; Contrast Media; Helium; Image Enhancement; Isotopes; Lung; Magnetic Resonance Imaging; Magnetic Resonance Spectroscopy; Male; Phantoms, Imaging; Pulmonary Embolism; Rats; Rats, Sprague-Dawley; Regional Blood Flow | 2001 |
Combined MR proton lung perfusion/angiography and helium ventilation: potential for detecting pulmonary emboli and ventilation defects.
Topics: Airway Obstruction; Animals; Feasibility Studies; Helium; Imaging, Three-Dimensional; Isotopes; Magnetic Resonance Angiography; Magnetic Resonance Imaging; Pulmonary Embolism; Pulmonary Ventilation; Swine; Ventilation-Perfusion Ratio | 2002 |
Effects of pulmonary gas embolism on circulation and respiration in the dog. V. Effect of changing breathing gas composition on pulmonary gas embolization.
Topics: Animals; Blood Pressure; Dogs; Female; Helium; Infusions, Parenteral; Male; Nitrogen; Oxygen; Pulmonary Alveoli; Pulmonary Artery; Pulmonary Embolism; Respiration | 1978 |
Effect of ventilation with different gas mixtures on experimental lung air embolism.
Topics: Animals; Blood Pressure; Dogs; Embolism, Air; Fluorides; Gases; Helium; Nitrous Oxide; Oxygen; Pulmonary Embolism; Respiration; Sulfur | 1978 |
[Subclinical lesions in animals subjected to experimental deep diving].
Topics: Animals; Brain; Brain Edema; Decompression Sickness; Diving; Guinea Pigs; Helium; Hemorrhage; Hydrogen; Lung; Male; Oxygen; Pulmonary Embolism; Rabbits; Rats; Testis | 1974 |
Acute changes in lung mechanics following pulmonary emboli of various gases in dogs.
Topics: Animals; Argon; Carbon Dioxide; Disease Models, Animal; Dogs; Embolism, Air; Endotoxins; Gases; Helium; Heparin; Injections, Intravenous; Lung; Lung Compliance; Male; Neon; Nitrogen; Oxygen; Pulmonary Circulation; Pulmonary Embolism; Respiration; Serotonin Antagonists; Thrombocytopenia; Xenon | 1972 |