Page last updated: 2024-10-28

glutaral and Health Care Associated Infection

glutaral has been researched along with Health Care Associated Infection in 60 studies

Glutaral: One of the protein CROSS-LINKING REAGENTS that is used as a disinfectant for sterilization of heat-sensitive equipment and as a laboratory reagent, especially as a fixative.
glutaraldehyde : A dialdehyde comprised of pentane with aldehyde functions at C-1 and C-5.

Research Excerpts

ExcerptRelevanceReference
"Most bacteria that cause nosocomial infections can retain their viability even after exposure to disinfectants in routine practice."1.37[Investigation of the efficacy of some disinfectants against nosocomial Staphylococcus aureus and Enterococcus spp. isolates]. ( Akın, A; Arıkan Akan, O; Eryılmaz, M, 2011)
"Although outbreaks of Mycobacterium abscessus infection have been reported, none of these reports has identified the potential sources of infection and modes of transmission."1.36An outbreak of skin and soft tissue infection caused by Mycobacterium abscessus following acupuncture. ( Chang, KJ; Choi, JW; Chu, CS; Jeong, JG; Kang, YA; Kang, YH; Koh, SJ; Lee, JY; Song, MK; Song, T; Sung, HY; Yim, JJ, 2010)
"Nosocomial infections have occasionally been linked wih the use of unsterile inhalation devices; microbial contamination of sterile nasal hoods routinely occurs during administration of nitrous oxide; and in vitro experiments indicate that subsequent use of contaminated nasal masks may lead to aspiration of microorganisms."1.26Disinfection of nitrous oxide inhalation equipment. ( Hunt, DE; Hunt, LM; Yagiela, JA, 1979)

Research

Studies (60)

TimeframeStudies, this research(%)All Research%
pre-199015 (25.00)18.7374
1990's20 (33.33)18.2507
2000's13 (21.67)29.6817
2010's11 (18.33)24.3611
2020's1 (1.67)2.80

Authors

AuthorsStudies
Aranke, M1
Moheimani, R1
Phuphanich, M1
Kaye, AD1
Ngo, AL1
Viswanath, O1
Herman, J1
Bradford, BD1
Seiberling, KA1
Park, FE1
Hiebert, JC1
Chang, DF1
Gilling, PJ1
Reuther, RM1
Addidle, M1
Lockhart, MM1
Frampton, CM1
Fraundorfer, MR1
Baruque Villar, G1
de Mello Freitas, FT1
Pais Ramos, J1
Dias Campos, CE1
de Souza Caldas, PC1
Santos Bordalo, F1
Amorim Ramos, TC1
do Nascimento Pereira, V1
Cordeiro-Santos, M1
Abdalla Santos, JH1
Coelho Motta, G1
Gomes, SM1
Mendes de Souza, VM1
de Araujo, WN1
Rutala, WA3
Gergen, MF2
Bringhurst, J1
Weber, DJ2
Sehmi, SK1
Allan, E1
MacRobert, AJ1
Parkin, I1
Koh, SJ1
Song, T1
Kang, YA1
Choi, JW1
Chang, KJ1
Chu, CS1
Jeong, JG1
Lee, JY1
Song, MK1
Sung, HY1
Kang, YH1
Yim, JJ1
Pitombo, MB1
Lupi, O1
Duarte, RS1
Yousefshahi, F1
Khajavi, MR1
Anbarafshan, M1
Khashayar, P1
Najafi, A1
Orsi, IA1
Villabona, CA1
Kameoka, E1
Ferreira, MC1
Ito, IY1
Saravia, ME1
Eryılmaz, M1
Akın, A1
Arıkan Akan, O1
Tschudin-Sutter, S1
Frei, R1
Kampf, G1
Tamm, M1
Pflimlin, E1
Battegay, M1
Widmer, AF1
Casalegno, JS1
Le Bail Carval, K1
Eibach, D1
Valdeyron, ML1
Lamblin, G1
Jacquemoud, H1
Mellier, G1
Lina, B1
Gaucherand, P1
Mathevet, P1
Mekki, Y1
Hernández, A2
Martró, E2
Puzo, C1
Matas, L2
Burgués, C1
Vázquez, N1
Castella, J1
Ausina, V2
RITTENBURY, MS1
HENCH, ME1
Henoun Loukili, N1
Becker, H1
Harno, J1
Bientz, M1
Meunier, O1
Reynaldo, MB1
Flores, MB1
Viegas Caetano, JA1
Magariños, Mdel C1
Brown, LM1
Osato, M1
You, WC1
El-Zimaity, H1
Li, JY1
Zhang, L1
Gail, MH1
Muscarella, LF1
Crovatto, M1
Martelli, P1
Santini, GF1
Battistin, M1
Hopfer, RL1
Babb, JR1
Bradley, CR2
Mwaniki, DL1
Orange, G1
Courtney, JM1
Hutson, P1
Dodd, M1
Deva, AK1
Vickery, K1
Zou, J1
West, RH1
Harris, JP1
Cossart, YE1
Fraise, AP1
Bochet, G1
Budtz-Jørgensen, E1
Tadeusiak, B1
Meiller, TF1
Depaola, LG1
Kelley, JI1
Baqui, AA1
Turng, BF1
Falkler, WA1
Boucher, RM1
Cronmiller, JR1
Nelson, DK1
Jackson, DK1
Kim, CH1
Herruzo-Cabrera, R1
Uriarte, MC1
Rey-Calero, J1
Middleton, AM1
Chadwick, MV1
Sanderson, JL1
Gaya, H1
Dauendorffer, JN1
Laurain, C1
Weber, M1
Dailloux, M1
Kressel, AB1
Kidd, F1
Knieler, R1
Ruddy, M1
Kibbler, CC1
Davis, JP1
Gutman, LT1
Higgins, MV1
Katz, SL1
Welt, SI1
Wilfert, CM1
Yagiela, JA1
Hunt, LM1
Hunt, DE1
Starościak, BJ1
Szych, J1
Zajdel, J1
Dobrzański, WT1
Lumley, J1
Postic, D1
Loiseau-Marolleau, ML1
Gimbert, JL1
Foss, D1
Monagan, D1
Nolan, CM1
Hashisaki, PA1
Dundas, DF1
Fulford, MR1
Hanson, PJ1
Lugliè, PF1
Delogu, D1
Forteleoni, GP1
Delogu, PL1
Bossù, M1
Isenberg, HD1
Gurevich, I1
Axon, AT1
Phillips, I1
Cotton, PB1
Avery, SA1
Kaboth, U1
Junge, U1
Duncalf, D1
Kelsey, JC1
Mackinnon, IH1
Maurer, IM1

Reviews

4 reviews available for glutaral and Health Care Associated Infection

ArticleYear
Disinfectants In Interventional Practices.
    Current pain and headache reports, 2021, Mar-11, Volume: 25, Issue:4

    Topics: Chlorine Compounds; Cross Infection; Disinfectants; Ethanol; Formaldehyde; Glutaral; Humans; Hydroge

2021
Endoscopic decontamination: an audit and practical review.
    The Journal of hospital infection, 2002, Volume: 50, Issue:4

    Topics: Cross Infection; Decontamination; Disinfectants; Endoscopes; Equipment Contamination; Glutaral; Guid

2002
AIDS: practising safe endoscopy.
    Bailliere's clinical gastroenterology, 1990, Volume: 4, Issue:2

    Topics: Acquired Immunodeficiency Syndrome; Cross Infection; Disinfection; Endoscopy; Equipment Contaminatio

1990
Prophylaxis of viral hepatitis.
    Clinics in gastroenterology, 1974, Volume: 3, Issue:2

    Topics: Autopsy; Blood Donors; Blood Transfusion; Carrier State; Chronic Disease; Cross Infection; Ethylene

1974

Trials

2 trials available for glutaral and Health Care Associated Infection

ArticleYear
A randomised single-blind comparison of the effectiveness of Tristel Fuse (chlorine dioxide) as an office-based fluid soak, with Cidex OPA (ortho-phthaldehyde) using an automated endoscopic reprocessor (AER) as high-level disinfection for flexible cystosc
    BJU international, 2013, Volume: 112 Suppl 2

    Topics: Adult; Aged; Aged, 80 and over; Chlorine Compounds; Cross Infection; Cystoscopes; Disinfectants; Dis

2013
Sanosil, a more effective agent for preventing the hospital-acquired ventilator associated pneumonia.
    International journal of health care quality assurance, 2010, Volume: 23, Issue:6

    Topics: Cross Infection; Disinfectants; Fungi; Glutaral; Gram-Negative Bacteria; Gram-Positive Bacteria; Hum

2010

Other Studies

54 other studies available for glutaral and Health Care Associated Infection

ArticleYear
Disinfection of rigid nasal endoscopes following in vitro contamination with Staphylococcus aureus, Streptococcus pneumoniae, Pseudomonas aeruginosa, and Haemophilus influenzae.
    JAMA otolaryngology-- head & neck surgery, 2013, Volume: 139, Issue:6

    Topics: Cross Infection; Disinfectants; Disinfection; Endoscopes; Equipment Contamination; Glutaral; Haemoph

2013
Risk Factors for Mycobacterium abscessus subsp. bolletii infection after laparoscopic surgery during an outbreak in Brazil.
    Infection control and hospital epidemiology, 2015, Volume: 36, Issue:1

    Topics: Adult; Aged; Aged, 80 and over; Brazil; Cross Infection; Digestive System Surgical Procedures; Disea

2015
Effective High-Level Disinfection of Cystoscopes: Is Perfusion of Channels Required?
    Infection control and hospital epidemiology, 2016, Volume: 37, Issue:2

    Topics: Academic Medical Centers; Colony Count, Microbial; Cross Infection; Cystoscopes; Disinfectants; Disi

2016
The bactericidal activity of glutaraldehyde-impregnated polyurethane.
    MicrobiologyOpen, 2016, Volume: 5, Issue:5

    Topics: Anti-Bacterial Agents; Cross Infection; Disinfectants; Escherichia coli; Glutaral; Materials Testing

2016
An outbreak of skin and soft tissue infection caused by Mycobacterium abscessus following acupuncture.
    Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases, 2010, Volume: 16, Issue:7

    Topics: Acupuncture Therapy; Case-Control Studies; Cross Infection; Disease Outbreaks; Disinfection; Equipme

2010
[Infections by rapidly growing mycobacteria resistant to disinfectants: a national matter?].
    Revista brasileira de ginecologia e obstetricia : revista da Federacao Brasileira das Sociedades de Ginecologia e Obstetricia, 2009, Volume: 31, Issue:11

    Topics: Brazil; Cross Infection; Disinfectants; Glutaral; Humans; Mycobacterium; Mycobacterium Infections; P

2009
Antimicrobial efficacy of chemical disinfectants on contaminated full metal crowns.
    Brazilian dental journal, 2010, Volume: 21, Issue:3

    Topics: Anti-Infective Agents; Cross Infection; Crowns; Decontamination; Dental Alloys; Dental Disinfectants

2010
[Investigation of the efficacy of some disinfectants against nosocomial Staphylococcus aureus and Enterococcus spp. isolates].
    Mikrobiyoloji bulteni, 2011, Volume: 45, Issue:3

    Topics: 2-Propanol; Chlorhexidine; Cross Infection; Disinfectants; Drug Resistance, Bacterial; Enterococcus;

2011
Emergence of glutaraldehyde-resistant Pseudomonas aeruginosa.
    Infection control and hospital epidemiology, 2011, Volume: 32, Issue:12

    Topics: Cross Infection; Disease Outbreaks; Disinfectants; Drug Resistance, Bacterial; Electrophoresis, Gel,

2011
High risk HPV contamination of endocavity vaginal ultrasound probes: an underestimated route of nosocomial infection?
    PloS one, 2012, Volume: 7, Issue:10

    Topics: Anti-Infective Agents, Local; Cross Infection; Disinfectants; Disinfection; DNA, Viral; Equipment Co

2012
In-use evaluation of Perasafe compared with Cidex in fibreoptic bronchoscope disinfection.
    The Journal of hospital infection, 2003, Volume: 54, Issue:1

    Topics: Bronchoscopes; Cross Infection; Disinfectants; Equipment Contamination; Glutaral; Humans; Infection

2003
In-vitro evaluation of Perasafe compared with 2% alkaline glutaraldehyde against Mycobacterium spp.
    The Journal of hospital infection, 2003, Volume: 54, Issue:1

    Topics: Cross Infection; Disinfectants; Glutaral; Humans; Infection Control; Microbial Sensitivity Tests; My

2003
PRELIMINARY EVALUATION OF AN ACTIVATED GLUTARALDEHYDE SOLUTION FOR COLD STERILIZATION.
    Annals of surgery, 1965, Volume: 161

    Topics: Aldehydes; Bacteriological Techniques; Cold Temperature; Cross Infection; Equipment and Supplies, Ho

1965
Effect of peracetic acid and aldehyde disinfectants on biofilm.
    The Journal of hospital infection, 2004, Volume: 58, Issue:2

    Topics: Biofilms; Cross Infection; Disinfectants; Equipment Contamination; Escherichia coli; Glutaral; Human

2004
[Efficacy of biocides against hospital isolates of Staphylococcus sensitive and resistant to methicillin, in the province of Buenos Aires, Argentina].
    Revista panamericana de salud publica = Pan American journal of public health, 2004, Volume: 16, Issue:3

    Topics: Adolescent; Adult; Aged; Anti-Infective Agents, Local; Argentina; Benzalkonium Compounds; Child; Chl

2004
Disinfection of endoscopes from Helicobacter pylori-positive subjects: evaluation of the effectiveness of the Chinese Calijing disinfection kit.
    American journal of infection control, 2005, Volume: 33, Issue:4

    Topics: Cross Infection; Disinfection; Endoscopes, Gastrointestinal; Equipment Contamination; Glutaral; Heli

2005
The risk of disease transmission associated with inadequate disinfection of gastrointestinal endoscopes.
    The Journal of hospital infection, 2006, Volume: 63, Issue:3

    Topics: Bacterial Infections; Cross Infection; Disinfection; Endoscopes, Gastrointestinal; Equipment Contami

2006
Disinfection of a probe used in ultrasound-guided prostate biopsy.
    Infection control and hospital epidemiology, 2007, Volume: 28, Issue:8

    Topics: Colony Count, Microbial; Cross Infection; Disinfectants; Disinfection; Glutaral; Humans; Male; Pseud

2007
[Activity of glutaraldehyde solutions against various bacterial strains isolated in hospital].
    Bollettino chimico farmaceutico, 1984, Volume: 123, Issue:12

    Topics: Aldehydes; Bacteria; Cross Infection; Glutaral; Humans

1984
Acid glutaraldehyde performs differently.
    The Journal of the Operating Room Research Institute : JORRI, 1982, Volume: 2, Issue:12

    Topics: Aldehydes; Cross Infection; Disinfectants; Glutaral; Humans

1982
Endoscope decontamination: where do we go from here?
    The Journal of hospital infection, 1995, Volume: 30 Suppl

    Topics: Cross Infection; Disinfectants; Disinfection; Endoscopes; Equipment Contamination; Glutaral; Humans;

1995
Liquid disinfecting and sterilization reprocessors used for flexible endoscopes.
    Health devices, 1994, Volume: 23, Issue:6

    Topics: Bronchoscopes; Bronchoscopy; Cross Infection; Disinfection; Endoscopy, Digestive System; Equipment a

1994
Contamination of the modified olympus EW-10 and EW-20 automatic flexible endoscope reprocessors.
    Health devices, 1994, Volume: 23, Issue:4

    Topics: Cross Infection; Disinfection; Endoscopes; Equipment Contamination; Equipment Design; Glutaral; Huma

1994
Biocidal effects and residual glutaraldehyde in cellulosic and synthetic polymers.
    East African medical journal, 1993, Volume: 70, Issue:3

    Topics: Acrylic Resins; Acrylonitrile; Cellulose; Cross Infection; Dialysis; Drug Evaluation, Preclinical; E

1993
A cause for concern.
    The British journal of theatre nursing : NATNews : the official journal of the National Association of Theatre Nurses, 1993, Volume: 2, Issue:10

    Topics: Cross Infection; Endoscopes; Glutaral; Humans; Peroxides; Sterilization; Sulfuric Acids

1993
Establishment of an in-use testing method for evaluating disinfection of surgical instruments using the duck hepatitis B model.
    The Journal of hospital infection, 1996, Volume: 33, Issue:2

    Topics: Animals; Biopsy; Cross Infection; Disease Models, Animal; Disinfection; Drug Evaluation, Preclinical

1996
Reprocessing of flexible gastrointestinal endoscopes. American Society for Gastrointestinal Endoscopy.
    Gastrointestinal endoscopy, 1996, Volume: 43, Issue:5

    Topics: Bacteria; Cross Infection; Disinfection; Endoscopes, Gastrointestinal; Equipment Contamination; Gast

1996
Heat and chemical resistance of enterococci.
    The Journal of hospital infection, 1996, Volume: 34, Issue:3

    Topics: Alcohols; Chlorine; Cross Infection; Disinfectants; Disinfection; Drug Resistance, Microbial; Entero

1996
[The effect of a disinfecting solution on the technical quality of reversible hydrocolloid impressions].
    Schweizer Monatsschrift fur Zahnmedizin = Revue mensuelle suisse d'odonto-stomatologie = Rivista mensile svizzera di odontologia e stomatologia, 1996, Volume: 106, Issue:11

    Topics: Colloids; Cross Infection; Dental Impression Materials; Dental Impression Technique; Disinfectants;

1996
[Sensitivity to disinfectants of Candid albicans strains isolated from the hospital environment].
    Roczniki Panstwowego Zakladu Higieny, 1998, Volume: 49, Issue:1

    Topics: Candida albicans; Candidiasis; Chloramines; Cross Infection; Disinfectants; Formaldehyde; Glutaral;

1998
Failure of endoscopy disinfection in St George's Hospital, Tooting.
    Communicable disease report. CDR weekly, 1998, Aug-28, Volume: 8, Issue:35

    Topics: Cross Infection; Disinfection; Endoscopes; England; Equipment Contamination; Equipment Failure; Glut

1998
Dental unit waterlines: biofilms, disinfection and recurrence.
    Journal of the American Dental Association (1939), 1999, Volume: 130, Issue:1

    Topics: 2-Propanol; Anti-Bacterial Agents; Bacteria; Biofilms; Colony Count, Microbial; Cross Infection; Den

1999
Stability of glutaraldehyde disinfectants during storage and use in hospitals.
    Respiratory care, 1978, Volume: 23, Issue:11

    Topics: Aldehydes; Cross Infection; Disinfectants; Drug Stability; Drug Storage; Equipment and Supplies, Hos

1978
Efficacy of conventional endoscopic disinfection and sterilization methods against Helicobacter pylori contamination.
    Helicobacter, 1999, Volume: 4, Issue:3

    Topics: Cross Infection; Disinfection; Endoscopes; Equipment Contamination; Ethanol; Glutaral; Helicobacter

1999
Antimicrobial effectiveness of 2% glutaraldehyde versus other disinfectants for hospital equipment, in an in vitro test based on germ-carriers with a high microbial contamination.
    Revue de stomatologie et de chirurgie maxillo-faciale, 1999, Volume: 100, Issue:6

    Topics: Aldehydes; Chlorhexidine; Colony Count, Microbial; Cross Infection; Disinfectants; Equipment and Sup

1999
Comparison of a solution of super-oxidized water (Sterilox) with glutaraldehyde for the disinfection of bronchoscopes, contaminated.
    The Journal of hospital infection, 2000, Volume: 45, Issue:4

    Topics: Bronchoscopes; Cross Infection; Disinfectants; Equipment Contamination; Glutaral; Humans; Hydrogen P

2000
Evaluation of the bactericidal efficiency of a 2% alkaline glutaraldehyde solution on Mycobacterium xenopi.
    The Journal of hospital infection, 2000, Volume: 46, Issue:1

    Topics: Cross Infection; Disinfectants; France; Glutaral; Humans; Mycobacterium Infections, Nontuberculous;

2000
Pseudo-outbreak of Mycobacterium chelonae and Methylobacterium mesophilicum caused by contamination of an automated endoscopy washer.
    Infection control and hospital epidemiology, 2001, Volume: 22, Issue:7

    Topics: Academic Medical Centers; Bronchoscopes; Cross Infection; Disease Outbreaks; Disinfection; DNA Finge

2001
Manual cleaning and disinfection of flexible endoscopes--an approach to evaluating a combined procedure.
    The Journal of hospital infection, 2001, Volume: 48 Suppl A

    Topics: Bacillus subtilis; Cross Infection; Disinfectants; Disinfection; Drug Evaluation, Preclinical; Endos

2001
Nasal colonization of infants with group B Streptococcus associated with intrauterine pressure transducers.
    The Journal of infectious diseases, 1978, Volume: 138, Issue:6

    Topics: Cross Infection; Female; Fetal Monitoring; Glutaral; Humans; Infant; Infant, Newborn; Infant, Newbor

1978
Disinfection of nitrous oxide inhalation equipment.
    Journal of the American Dental Association (1939), 1979, Volume: 98, Issue:2

    Topics: Aldehydes; Alkalies; Anesthesia, Dental; Anesthesia, Inhalation; Bacteria; Cross Infection; Dental E

1979
[Sporicidal activity of Aldesan. Sterilization of hospital instruments with this preparation].
    Polski tygodnik lekarski (Warsaw, Poland : 1960), 1979, Jun-11, Volume: 34, Issue:24

    Topics: Aldehydes; Cross Infection; Glutaral; Humans; Spores, Bacterial; Sterilization

1979
Decontamination of anaesthetic equipment and ventilators.
    British journal of anaesthesia, 1976, Volume: 48, Issue:1

    Topics: Anesthesiology; Benzalkonium Compounds; Chlorhexidine; Cross Infection; Disinfection; Disposable Equ

1976
[Contamination of a bronchofibroscope by Pseudomonas aeruginosa].
    La Nouvelle presse medicale, 1978, Feb-04, Volume: 7, Issue:5

    Topics: Bronchoscopes; Cross Infection; Disinfection; Glutaral; Humans; Pseudomonas Infections

1978
A national survey of physicians' and nurses' attitudes toward endoscope cleaning and the potential for cross-infection.
    Gastroenterology nursing : the official journal of the Society of Gastroenterology Nurses and Associates, 1992, Volume: 15, Issue:2

    Topics: Attitude of Health Personnel; Cross Infection; Endoscopes, Gastrointestinal; Female; Glutaral; HIV I

1992
An outbreak of soft-tissue infections due to Mycobacterium fortuitum associated with electromyography.
    The Journal of infectious diseases, 1991, Volume: 163, Issue:5

    Topics: Adult; Cross Infection; Disease Outbreaks; Disinfection; Electrodes; Electromyography; Female; Gluta

1991
'Glutaraldehyde'.
    British dental journal, 1991, May-11, Volume: 170, Issue:9

    Topics: Cross Infection; Glutaral; Humans

1991
APIC guideline for selection and use of disinfectants.
    American journal of infection control, 1990, Volume: 18, Issue:2

    Topics: 1-Propanol; Chlorine; Cross Infection; Disinfectants; Ethanol; Formaldehyde; Glutaral; Humans; Hydro

1990
[The evaluation of the size variations in alginate subjected to the sterilizing action of glutaraldehyde].
    Minerva stomatologica, 1990, Volume: 39, Issue:12

    Topics: Alginates; Bacterial Infections; Cross Infection; Dental Impression Technique; Drug Interactions; Gl

1990
Clinical laboratory studies of disinfection with Sporicidin.
    Journal of clinical microbiology, 1985, Volume: 22, Issue:5

    Topics: Aldehydes; Cross Infection; Dose-Response Relationship, Drug; Glutaral; Humans; Microbial Sensitivit

1985
The disinfectant dilemma.
    Infection control : IC, 1985, Volume: 6, Issue:11

    Topics: Aldehydes; Cross Infection; Disinfection; Glutaral; Humans; Mycobacterium tuberculosis; Sterilizatio

1985
Disinfection of gastrointestinal fibre endoscopes.
    Lancet (London, England), 1974, Volume: 1, Issue:7859

    Topics: Aldehydes; Biopsy; Cross Infection; Endoscopes; Ethanol; Fiber Optic Technology; Glutaral; Hepatitis

1974
Care of anesthetic equipment and other devices.
    Archives of surgery (Chicago, Ill. : 1960), 1973, Volume: 107, Issue:4

    Topics: 1-Propanol; Anesthesiology; Cross Infection; Electronics, Medical; Ethylene Oxide; Glutaral; Hot Tem

1973
Sporicidal activity of hospital disinfectants.
    Journal of clinical pathology, 1974, Volume: 27, Issue:8

    Topics: Aldehydes; Bacillus subtilis; Cell Survival; Corrosion; Cross Infection; Disinfectants; Equipment an

1974