Page last updated: 2024-10-18

formaldehyde and Aneurysm, Aortic

formaldehyde has been researched along with Aneurysm, Aortic in 60 studies

paraform: polymerized formaldehyde; RN given refers to parent cpd; used in root canal therapy

Research Excerpts

ExcerptRelevanceReference
"Gelatin-resorcin-formaldehyde (GRF) glue has been widely applied during operations for acute aortic dissection (AAD)."7.73Late complications following surgery for type A acute aortic dissection using gelatin-resorcin-formaldehyde glue: report of two cases. ( Izumoto, H; Kamada, T; Kawazoe, K; Nakajima, T; Sugai, T; Yoshioka, K, 2005)
"Because an excessive use of activator (formaldehyde + glutaraldehyde) is supposed to be responsible for later adverse events after the use of gelatin resorcin formalin (GRF) glue in surgery for acute aortic dissection, we have tried to use a minimum dose of activator when the GRF glue was applied."3.74Recommendation for appropriate use of GRF glue in the operation for acute aortic dissection. ( Kunihara, T; Matsui, Y; Matsuzaki, K; Murashita, T; Shiiya, N, 2008)
"Gelatin-resorcin-formaldehyde (GRF) glue has been widely applied during operations for acute aortic dissection (AAD)."3.73Late complications following surgery for type A acute aortic dissection using gelatin-resorcin-formaldehyde glue: report of two cases. ( Izumoto, H; Kamada, T; Kawazoe, K; Nakajima, T; Sugai, T; Yoshioka, K, 2005)
"Gelatin-resorcin-formaldehyde-glutaraldehyde (GRF) biologic glue is an available adjunct to repair acute ascending aortic dissections."3.69Aortic dissection repair with GRF glue complicated by heart block. ( Brink, JG; Chimuka, D; Von Oppell, UO; Zilla, P, 1995)
"Between 1984 and 1988, 15 patients with type A aortic dissection were treated by direct suturing of the intimal tear and extensive sticking of the dissected aortic layers with surgical (gelatin-resorcin-formaldehyde) glue without prosthetic graft replacement."3.67Use of surgical glue without replacement in the treatment of type A aortic dissection. ( Carpentier, A; Deloche, A; Fabiani, JN; Jebara, VA; Stephan, Y, 1989)
"Type A aortic dissection is a life-threatening disease requiring immediate surgical treatment."1.43Type A aortic dissection model to improve endovascular research and technologies. ( Bombien, R; Carrel, T; Heinisch, PP; Khoynezhad, A; Klaws, R; Weidenhagen, R; Winkler, B, 2016)
"Aortic dissection is an evolving process that may require one or several reoperations after its initial repair."1.38Reoperation after surgical correction of acute type A aortic dissection: risk factor analysis. ( Casali, G; Concistrè, G; Dell'Aquila, A; Fiorani, B; Montalto, A; Musumeci, F; Santaniello, E, 2012)
"An echocardiogram showed severe aortic regurgitation associated with aortic root enlargement."1.38A case of ascending aortic pseudoaneurysm in a patient with aortic replacement. ( Aizawa, K; Ishida, Y; Misawa, Y; Muraoka, A; Ohki, S; Sakano, Y, 2012)
"Residual aortic regurgitation (AR) was evaluated, grading 0 to IV+ by echocardiography."1.34[Durability of aortic root preservation using gelatin-resorcin-formalin glue in acute type A aortic dissection]. ( Aoki, K; Kanazawa, H; Nakazawa, S; Takahashi, Y; Yamazaki, Y, 2007)
"Five patients developed an aortic pseudoaneurysm at the anastomotic site and underwent a late reoperation."1.34Late complications of gelatin-resorcin-formalin glue in the repair of acute type A aortic dissection. ( Fukushima, N; Hata, H; Kawaguchi, N; Matsumiya, G; Sawa, Y; Takano, H, 2007)
"We review cases of pseudoaneurysm formation of the graft anastomosis sites following repair of type A acute aortic dissection by our original leak-proof technique for dissected aortic wall reinforcement with xenopericardium and gelatin-resorcinol-formalin (GRF) glue."1.34Devastating late complication for repair of type A acute aortic dissection with usage of gelatin-resorcinol-formalin glue. ( Ishibashi, K; Izutani, H; Kawamoto, J; Nishikawa, D; Shibukawa, T, 2007)
"A 62-year-old man presenting with congestive heart failure due to a fistula between an aortic pseudoaneurysm and the right pulmonary artery is described."1.33Aortopulmonary fistula occurring 4 years after replacement of the ascending aorta. ( Blank, R; Genoni, M; Künzli, A; Maeder, MT; Rickli, H; Wolber, T, 2006)
"Coronary pseudoaneurysms are a known complication of the Bentall wrap-inclusion method of composite valve grafting."1.31A simple trick for repairing coronary pseudoaneurysm complicating a Bentall operation. ( Miller, DC; Schmoker, JD, 2002)
"The operative mortality for ascending aortic dissections was 24."1.31Dissected aortic sinuses repaired with gelatin-resorcin-formaldehyde (GRF) glue are not stable on follow up. ( Brink, J; Brooks, A; Karani, Z; von Oppell, UO, 2002)
"In operations for aortic dissection anastomotic bleeding or secondary anastomosis dehiscence are common problems."1.30Glue containment and anastomosis reinforcement in repair of aortic dissection. ( Capannini, G; Carone, E; Massetti, M; Neri, E; Sassi, C, 1999)
"In conclusion, aortic dissection is an evolving process that may require one or several reoperations after the initial repair."1.29Aortic dissection. Prevalence, cause, and results of late reoperations. ( Bachet, JE; Brodaty, D; Delentdecker, P; Dreyfus, G; Dubois, C; Goudot, B; Guilmet, D; Martinelli, L; Piquois, A; Termignon, JL, 1994)

Research

Studies (60)

TimeframeStudies, this research(%)All Research%
pre-19909 (15.00)18.7374
1990's21 (35.00)18.2507
2000's24 (40.00)29.6817
2010's6 (10.00)24.3611
2020's0 (0.00)2.80

Authors

AuthorsStudies
Ohno, N1
Minatoya, K1
Heinisch, PP1
Winkler, B1
Weidenhagen, R1
Klaws, R1
Carrel, T3
Khoynezhad, A1
Bombien, R1
Kazui, T1
Mitsunaga, Y1
Fukuhiro, Y1
Nakajima, T2
Okabayashi, H1
McLachlan, CS1
Lorraine, P1
Peter, M1
Imoto, K2
Martinca, T1
Jonák, M1
Tonar, Z1
Witter, K1
Matejka, VM1
Rokosný, S1
Concistrè, G1
Casali, G1
Santaniello, E1
Montalto, A1
Fiorani, B1
Dell'Aquila, A1
Musumeci, F1
Ishida, Y1
Sakano, Y1
Ohki, S1
Muraoka, A1
Aizawa, K1
Misawa, Y1
Schmoker, JD1
Miller, DC1
HENROTIN, E1
Yoshitatsu, M1
Nomura, F1
Katayama, A1
Tamura, K1
Katayama, K1
Ihara, K1
Nakashima, Y1
Takarabe, K1
Ohtsubo, S1
Itoh, T1
Rikitake, K1
Furukawa, K1
Okazaki, Y1
Natsuaki, M1
Hata, M2
Shiono, M2
Sezai, A2
Iida, M1
Negishi, N2
Sezai, Y1
Mastroroberto, P2
Chello, M2
Onorati, F1
Renzulli, A1
Murata, A1
Nishiya, Y1
Saito, N1
Konuma, T1
Yusa, H1
Hoshino, S1
Kamada, T1
Izumoto, H1
Sugai, T1
Yoshioka, K1
Kawazoe, K1
Maeder, MT1
Wolber, T1
Künzli, A1
Genoni, M1
Blank, R1
Rickli, H1
Niino, T1
Yagi, S1
Aoki, K1
Nakazawa, S1
Takahashi, Y1
Kanazawa, H1
Yamazaki, Y1
Hata, H1
Takano, H1
Matsumiya, G1
Fukushima, N1
Kawaguchi, N1
Sawa, Y1
LeMaire, SA1
Izutani, H1
Shibukawa, T1
Kawamoto, J1
Ishibashi, K1
Nishikawa, D1
Bachet, J6
Trivi, M1
Albertal, J1
Vaccarino, G1
Albertal, M1
Navia, D1
Hachimaru, T1
Kawaguchi, S1
Watanabe, M1
Nakahara, H1
Kunihara, T1
Shiiya, N1
Matsuzaki, K1
Murashita, T1
Matsui, Y1
Bical, O3
Donzeau-Gouge, P1
Neveux, JY1
Gigou, F3
Laurian, C3
Goudot, B6
Dubois, C4
Brodaty, D4
Guilmet, D8
Loisance, D1
Maurer, M1
Tkebuchava, T1
Niederhäuser, U1
Schneider, J1
Turina, MI1
Von Oppell, UO2
Chimuka, D1
Brink, JG1
Zilla, P1
Bachet, JE1
Termignon, JL1
Dreyfus, G3
Martinelli, L1
Piquois, A1
Delentdecker, P3
Martinelli, GL1
Uchida, K1
Kondo, J1
Tobe, M1
Sakamoto, A1
Sugiyama, M1
Westaby, S3
Katsumata, T3
Freitas, E1
Goossens, D1
Schepens, M1
Hamerlijnck, R1
Hartman, M1
Suttorp, MJ1
Koomen, E1
Vermeulen, F1
Houel, R1
Shinfeld, A1
Bassiony, AA1
Shad, SK1
Rosin, MD1
Machii, M1
Sugimoto, T1
Sasaki, K1
Harada, A1
Neri, E1
Massetti, M1
Capannini, G1
Carone, E1
Sassi, C1
Nguyen, B1
Müller, M1
Kipfer, B1
Berdat, P1
Walpoth, B1
Althaus, U1
Dreyfus, GD1
De Paulis, R1
Matteucci, SL1
Penta de Peppo, A1
Chiariello, L1
Nishimori, H1
Hata, A1
Sasaguri, S1
Teimouri, F1
Ahmed, AA1
Mahadevan, VS1
Webb, SW1
MacGowan, SW1
Saito, S1
Karani, Z1
Brooks, A1
Brink, J1
Zeplin, HE1
Matsuda, K2
Tamura, N1
Iwakura, A1
Weinschelbaum, EE1
Schamun, C1
Caramutti, V1
Tacchi, H1
Cors, J1
Favaloro, RG1
Fabiani, JN3
Jebara, VA2
DeLoche, A3
Carpentier, A3
Jebara, V1
Stephan, Y2
Chachques, JC1
Paulista, PP1
Arnoni, AS1
De Souza, LC1
Jatene, AD1
Fichino, MZ1
Sousa, JE1

Reviews

2 reviews available for formaldehyde and Aneurysm, Aortic

ArticleYear
Reinforcement and reapproximation of the aortic stump during surgery for acute aortic dissection.
    Surgery today, 2019, Volume: 49, Issue:8

    Topics: Acute Disease; Anastomosis, Surgical; Aorta; Aortic Aneurysm; Aortic Dissection; Drug Combinations;

2019
Aortic dissection: anatomic types and surgical approaches.
    The Journal of cardiovascular surgery, 1993, Volume: 34, Issue:1

    Topics: Acute Disease; Aged; Aortic Aneurysm; Aortic Aneurysm, Thoracic; Aortic Dissection; Blood Vessel Pro

1993

Trials

1 trial available for formaldehyde and Aneurysm, Aortic

ArticleYear
Simplification of the Bentall procedure with surgical and biological innovations.
    European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery, 1994, Volume: 8, Issue:11

    Topics: Adult; Aged; Aorta; Aortic Aneurysm; Aortic Dissection; Aprotinin; Cardiac Catheterization; Cardiopu

1994

Other Studies

57 other studies available for formaldehyde and Aneurysm, Aortic

ArticleYear
Type A aortic dissection model to improve endovascular research and technologies.
    Asian cardiovascular & thoracic annals, 2016, Volume: 24, Issue:4

    Topics: Anatomic Landmarks; Aorta; Aortic Aneurysm; Aortic Dissection; Aortography; Blood Vessel Prosthesis;

2016
Aortic root reimplantation using a Valsalva graft for postoperative pseudoaneurysm after acute aortic dissection.
    Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia, 2008, Volume: 14, Issue:5

    Topics: Aneurysm, False; Aortic Aneurysm; Aortic Dissection; Aortography; Blood Vessel Prosthesis; Blood Ves

2008
Potential for felt complications in surgical aortic dissection repair.
    Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia, 2009, Volume: 15, Issue:1

    Topics: Anastomosis, Surgical; Aortic Aneurysm; Aortic Dissection; Drug Combinations; Equipment Design; Form

2009
Recent status of gelatin-resorcin-formalin glue for acute type A aortic dissection.
    General thoracic and cardiovascular surgery, 2011, Volume: 59, Issue:5

    Topics: Acute Disease; Adhesiveness; Animals; Aortic Aneurysm; Aortic Dissection; Drug Combinations; Formald

2011
[Effect of biological glues on vascular wall in an experimental model of aortic dissection].
    Rozhledy v chirurgii : mesicnik Ceskoslovenske chirurgicke spolecnosti, 2011, Volume: 90, Issue:2

    Topics: Animals; Aorta; Aortic Aneurysm; Aortic Dissection; Drug Combinations; Fibrin Tissue Adhesive; Forma

2011
Reoperation after surgical correction of acute type A aortic dissection: risk factor analysis.
    The Annals of thoracic surgery, 2012, Volume: 93, Issue:2

    Topics: Adult; Aged; Aged, 80 and over; Aortic Aneurysm; Aortic Dissection; Aortic Valve; Cardiopulmonary By

2012
A case of ascending aortic pseudoaneurysm in a patient with aortic replacement.
    General thoracic and cardiovascular surgery, 2012, Volume: 60, Issue:7

    Topics: Aneurysm, False; Aortic Aneurysm; Aortic Dissection; Aortic Valve Insufficiency; Aortography; Blood

2012
A simple trick for repairing coronary pseudoaneurysm complicating a Bentall operation.
    The Annals of thoracic surgery, 2002, Volume: 74, Issue:1

    Topics: Adult; Anastomosis, Surgical; Aneurysm, False; Aortic Aneurysm; Aortic Dissection; Cardiac Surgical

2002
[Aneurysms of the abdominal aorta; formalin-treated grafts].
    Acta chirurgica Belgica, 1956, Volume: 55, Issue:9

    Topics: Aneurysm; Aorta, Abdominal; Aortic Aneurysm; Arteries; Formaldehyde; Humans

1956
Pathologic findings of aortic redissection after glue repair of proximal aorta.
    The Journal of thoracic and cardiovascular surgery, 2004, Volume: 127, Issue:2

    Topics: Anastomosis, Surgical; Aorta, Thoracic; Aortic Aneurysm; Aortic Dissection; Blood Vessel Prosthesis

2004
Improved survival of surgery for acute type A aortic dissection: impact of noninvasive diagnosis and hemostatic surgical management.
    The Japanese journal of thoracic and cardiovascular surgery : official publication of the Japanese Association for Thoracic Surgery = Nihon Kyobu Geka Gakkai zasshi, 2004, Volume: 52, Issue:2

    Topics: Adult; Aged; Aortic Aneurysm; Aortic Dissection; Drug Combinations; Female; Formaldehyde; Gelatin; H

2004
Type A acute aortic dissection: immediate and mid-term results of emergency aortic replacement with the aid of gelatin resorcin formalin glue.
    The Annals of thoracic surgery, 2004, Volume: 78, Issue:3

    Topics: Actuarial Analysis; Adult; Aged; Aged, 80 and over; Anastomosis, Surgical; Aortic Aneurysm; Aortic D

2004
Embolisation, inflammatory reaction and persistent patent false lumen: is biological glue really effective in repair of type A aortic dissection?
    European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery, 2005, Volume: 27, Issue:3

    Topics: Acute Disease; Aortic Aneurysm; Aortic Dissection; Drug Combinations; Formaldehyde; Gelatin; Humans;

2005
[De Bakey type I aortic dissection complicating systemic lupus erythematosus; report of a case].
    Kyobu geka. The Japanese journal of thoracic surgery, 2005, Volume: 58, Issue:10

    Topics: Adult; Aorta; Aortic Aneurysm; Aortic Dissection; Aortic Valve Insufficiency; Blood Vessel Prosthesi

2005
Late complications following surgery for type A acute aortic dissection using gelatin-resorcin-formaldehyde glue: report of two cases.
    Surgery today, 2005, Volume: 35, Issue:11

    Topics: Aged; Aneurysm, False; Aortic Aneurysm; Aortic Dissection; Drug Combinations; Female; Formaldehyde;

2005
Aortopulmonary fistula occurring 4 years after replacement of the ascending aorta.
    The Annals of thoracic surgery, 2006, Volume: 81, Issue:5

    Topics: Aneurysm, False; Aortic Aneurysm; Aortic Diseases; Aortic Dissection; Aortic Valve; Aortic Valve Ste

2006
Late results of gelatin-resorcin-formalin glue-aided repair in acute type A aortic dissection.
    Artificial organs, 2006, Volume: 30, Issue:12

    Topics: Adolescent; Adult; Aged; Aged, 80 and over; Aortic Aneurysm; Aortic Dissection; Drug Combinations; F

2006
[Durability of aortic root preservation using gelatin-resorcin-formalin glue in acute type A aortic dissection].
    Kyobu geka. The Japanese journal of thoracic surgery, 2007, Volume: 60, Issue:4

    Topics: Acute Disease; Adult; Aged; Aged, 80 and over; Aorta; Aortic Aneurysm; Aortic Aneurysm, Thoracic; Ao

2007
Late complications of gelatin-resorcin-formalin glue in the repair of acute type A aortic dissection.
    The Annals of thoracic surgery, 2007, Volume: 83, Issue:5

    Topics: Adult; Aged; Aged, 80 and over; Aneurysm, False; Aortic Aneurysm; Aortic Dissection; Blood Vessel Pr

2007
Invited commentary.
    The Annals of thoracic surgery, 2007, Volume: 83, Issue:5

    Topics: Aneurysm, False; Aortic Aneurysm; Aortic Dissection; Blood Vessel Prosthesis Implantation; Drug Comb

2007
Devastating late complication for repair of type A acute aortic dissection with usage of gelatin-resorcinol-formalin glue.
    Interactive cardiovascular and thoracic surgery, 2007, Volume: 6, Issue:2

    Topics: Acute Disease; Anastomosis, Surgical; Aneurysm, False; Aortic Aneurysm; Aortic Dissection; Bioprosth

2007
ICVTS on-line discussion A. It's better to let well alone.
    Interactive cardiovascular and thoracic surgery, 2007, Volume: 6, Issue:2

    Topics: Acute Disease; Anastomosis, Surgical; Aneurysm, False; Aortic Aneurysm; Aortic Dissection; Bioprosth

2007
Ostial stenosis after Bentall technique using glue: percutaneous stenting may be ineffective.
    Interactive cardiovascular and thoracic surgery, 2007, Volume: 6, Issue:4

    Topics: Aortic Aneurysm; Aortic Valve Stenosis; Blood Vessel Prosthesis Implantation; Coronary Stenosis; Cor

2007
[Proximal anastomotic pseudoaneurysm due to gelatin-resorcin-formalin (GRF) glue after replacement of ascending aorta for acute aortic dissection; report of a case].
    Kyobu geka. The Japanese journal of thoracic surgery, 2008, Volume: 61, Issue:3

    Topics: Acute Disease; Aged; Aneurysm, False; Aorta; Aortic Aneurysm; Aortic Dissection; Blood Vessel Prosth

2008
Recommendation for appropriate use of GRF glue in the operation for acute aortic dissection.
    Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia, 2008, Volume: 14, Issue:2

    Topics: Adult; Aged; Anastomosis, Surgical; Aortic Aneurysm; Aortic Dissection; Drug Combinations; Female; F

2008
[Surgery of aortic dissections. Value of Tissucol compared with GRF (gelatin, resorcinol and formaldehyde) adhesive].
    Presse medicale (Paris, France : 1983), 1983, Sep-24, Volume: 12, Issue:33

    Topics: Aortic Aneurysm; Aortic Dissection; Drug Combinations; Factor XIII; Fibrin Tissue Adhesive; Fibrinog

1983
[4-year clinical experience with gelatin-resorcinol-formol glue in acute dissections of the ascending aorta].
    Archives des maladies du coeur et des vaisseaux, 1983, Volume: 76, Issue:1

    Topics: Acute Disease; Aortic Aneurysm; Aortic Dissection; Drug Combinations; Formaldehyde; Gelatin; Humans;

1983
Four-year clinical experience with the gelatin-resorcine-formol biological glue in acute aortic dissection.
    The Journal of thoracic and cardiovascular surgery, 1982, Volume: 83, Issue:2

    Topics: Adult; Aged; Aorta; Aortic Aneurysm; Aortic Dissection; Aortic Valve; Blood Vessel Prosthesis; Coron

1982
Embolization of biologic glue during repair of aortic dissection.
    The Annals of thoracic surgery, 1995, Volume: 60, Issue:4

    Topics: Aged; Aortic Aneurysm; Aortic Dissection; Brain; Cerebral Infarction; Drug Combinations; Fatal Outco

1995
Aortic dissection repair with GRF glue complicated by heart block.
    The Annals of thoracic surgery, 1995, Volume: 59, Issue:3

    Topics: Acute Disease; Aortic Aneurysm; Aortic Dissection; Cardiopulmonary Bypass; Drug Combinations; Female

1995
Aortic dissection. Prevalence, cause, and results of late reoperations.
    The Journal of thoracic and cardiovascular surgery, 1994, Volume: 108, Issue:2

    Topics: Acute Disease; Adolescent; Adult; Aged; Aortic Aneurysm; Aortic Dissection; Blood Vessel Prosthesis;

1994
Embolization of biological glue after repair of acute aortic dissection.
    The Annals of thoracic surgery, 1996, Volume: 62, Issue:3

    Topics: Aortic Aneurysm; Aortic Dissection; Drug Combinations; Formaldehyde; Gelatin; Humans; Intracranial E

1996
[Surgery for acute aortic dissection extending to the aortic root using gelatine-resorcine-formol biological glue--a case report].
    [Zasshi] [Journal]. Nihon Kyobu Geka Gakkai, 1997, Volume: 45, Issue:7

    Topics: Acute Disease; Aged; Aorta; Aortic Aneurysm; Aortic Dissection; Blood Vessel Prosthesis; Drug Combin

1997
Aortic valve conservation in acute type A dissection.
    The Annals of thoracic surgery, 1997, Volume: 64, Issue:4

    Topics: Adult; Aged; Aged, 80 and over; Aortic Aneurysm; Aortic Dissection; Aortic Rupture; Aortic Valve; Ao

1997
Predictors of hospital mortality in type A aortic dissections: a retrospective analysis of 148 consecutive surgical patients.
    Cardiovascular surgery (London, England), 1998, Volume: 6, Issue:1

    Topics: Aorta; Aortic Aneurysm; Aortic Dissection; Blood Vessel Prosthesis Implantation; Drug Combinations;

1998
Stentless xenograft repair of the dissected aortic root.
    The Annals of thoracic surgery, 1998, Volume: 65, Issue:5

    Topics: Aged; Anastomosis, Surgical; Aortic Aneurysm; Aortic Dissection; Aortic Valve; Aortic Valve Stenosis

1998
Absence of GRF glue effect two years after aortic repair.
    The Annals of thoracic surgery, 1999, Volume: 67, Issue:4

    Topics: Aged; Aortic Aneurysm; Aortic Dissection; Drug Combinations; Female; Formaldehyde; Gelatin; Humans;

1999
Aortic stump tailoring with GRF glue and a felt strip.
    Surgery today, 1999, Volume: 29, Issue:5

    Topics: Aorta; Aortic Aneurysm; Aortic Dissection; Blood Vessel Prosthesis; Drug Combinations; Formaldehyde;

1999
Glue containment and anastomosis reinforcement in repair of aortic dissection.
    The Annals of thoracic surgery, 1999, Volume: 67, Issue:5

    Topics: Anastomosis, Surgical; Aortic Aneurysm; Aortic Dissection; Drug Combinations; Formaldehyde; Gelatin;

1999
Different techniques of distal aortic repair in acute type A dissection: impact on late aortic morphology and reoperation.
    European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery, 1999, Volume: 15, Issue:4

    Topics: Aorta, Thoracic; Aortic Aneurysm; Aortic Dissection; Cardiac Surgical Procedures; Cardiopulmonary By

1999
Surgery for acute type A aortic dissection: the Hopital Foch experience (1977-1998).
    The Annals of thoracic surgery, 1999, Volume: 67, Issue:6

    Topics: Adolescent; Adult; Aged; Aortic Aneurysm; Aortic Dissection; Drug Combinations; Female; Formaldehyde

1999
Cyanoacrylate glue as an alternative to an additional suture line in the repair of type A aortic dissection.
    Texas Heart Institute journal, 1999, Volume: 26, Issue:4

    Topics: Aortic Aneurysm; Aortic Dissection; Cyanoacrylates; Drug Combinations; Formaldehyde; Gelatin; Humans

1999
Optimal application of gelatin-resorcin-formaldehyde glue with special reference to the quality of mixing.
    The Annals of thoracic surgery, 2000, Volume: 69, Issue:4

    Topics: Aortic Aneurysm; Aortic Dissection; Drug Combinations; Formaldehyde; Gelatin; Humans; Resorcinols; T

2000
Surgery of acute type A dissection: what have we learned during the past 25 years?
    Zeitschrift fur Kardiologie, 2000, Volume: 89 Suppl 7

    Topics: Acute Disease; Adolescent; Adult; Aged; Aged, 80 and over; Aorta; Aortic Aneurysm; Aortic Dissection

2000
Glue aortoplasty repair of aortic dissection after coronary angioplasty.
    The Annals of thoracic surgery, 2001, Volume: 72, Issue:3

    Topics: Angioplasty, Balloon, Coronary; Aortic Aneurysm; Aortic Dissection; Coronary Disease; Drug Combinati

2001
Acute type A dissection: conservative methods provide consistently low mortality.
    The Annals of thoracic surgery, 2002, Volume: 73, Issue:3

    Topics: Adult; Aged; Aged, 80 and over; Aortic Aneurysm; Aortic Dissection; Blood Vessel Prosthesis Implanta

2002
Dissected aortic sinuses repaired with gelatin-resorcin-formaldehyde (GRF) glue are not stable on follow up.
    The Journal of heart valve disease, 2002, Volume: 11, Issue:2

    Topics: Acute Disease; Adult; Aged; Aorta; Aortic Aneurysm; Aortic Dissection; Aortic Valve; Chronic Disease

2002
[Gelatin resorcin formaldehyde glue in vascular surgery (author's transl)].
    La Nouvelle presse medicale, 1977, Oct-22, Volume: 6, Issue:35

    Topics: Animals; Aortic Aneurysm; Aortic Dissection; Dogs; Formaldehyde; Gelatin; Hemostasis, Surgical; Huma

1977
Surgery of aortic dissections with GRF glue.
    The Annals of thoracic surgery, 1992, Volume: 54, Issue:6

    Topics: Aortic Aneurysm; Aortic Dissection; Cardiac Surgical Procedures; Drug Combinations; Formaldehyde; Ge

1992
[Surgical treatment of dissecting aortic aneurysm using GRF glue].
    Kyobu geka. The Japanese journal of thoracic surgery, 1992, Volume: 45, Issue:10

    Topics: Anastomosis, Surgical; Aorta, Thoracic; Aortic Aneurysm; Aortic Dissection; Drug Combinations; Femal

1992
[Surgery of dissecting aortic aneurysm using GRF glue].
    Nihon geka hokan. Archiv fur japanische Chirurgie, 1992, Mar-01, Volume: 61, Issue:2

    Topics: Aortic Aneurysm; Aortic Dissection; Drug Combinations; Formaldehyde; Gelatin; Humans; Resorcinols

1992
Surgical treatment of acute type A dissecting aneurysm, with preservation of the native aortic valve and use of biologic glue. Follow-up to 6 years.
    The Journal of thoracic and cardiovascular surgery, 1992, Volume: 103, Issue:2

    Topics: Adolescent; Adult; Aged; Aortic Aneurysm; Aortic Dissection; Aortic Valve Insufficiency; Blood Vesse

1992
Use of glue without graft replacement for type A dissections: a new surgical technique.
    The Annals of thoracic surgery, 1990, Volume: 50, Issue:1

    Topics: Aorta; Aortic Aneurysm; Aortic Dissection; Drug Combinations; Formaldehyde; Gelatin; Humans; Resorci

1990
The use of surgical glue without replacement in the treatment of type A aortic dissection.
    [Zasshi] [Journal]. Nihon Kyobu Geka Gakkai, 1989, Volume: 37 Suppl

    Topics: Aortic Aneurysm; Aortic Dissection; Blood Vessel Prosthesis; Drug Combinations; Formaldehyde; Gelati

1989
Use of surgical glue without replacement in the treatment of type A aortic dissection.
    Circulation, 1989, Volume: 80, Issue:3 Pt 1

    Topics: Acute Disease; Adult; Aged; Aorta, Thoracic; Aortic Aneurysm; Aortic Dissection; Drug Combinations;

1989
[Use of biological glue in the surgical treatment of aortic dissection--report of 3 cases].
    Arquivos brasileiros de cardiologia, 1988, Volume: 50, Issue:4

    Topics: Aorta; Aortic Aneurysm; Aortic Dissection; Aortography; Drug Combinations; Female; Formaldehyde; Gel

1988
[Surgical treatment of acute aortic dissection].
    Annales de cardiologie et d'angeiologie, 1985, Volume: 34, Issue:1

    Topics: Adolescent; Adult; Aged; Aortic Aneurysm; Aortic Dissection; Drug Combinations; Emergencies; Formald

1985