exudates has been researched along with Sick-Building-Syndrome* in 3 studies
3 other study(ies) available for exudates and Sick-Building-Syndrome
Article | Year |
---|---|
Association between indoor microbiome exposure and sick building syndrome (SBS) in junior high schools of Johor Bahru, Malaysia.
Sick building syndrome (SBS) is a collection of nonspecific syndromes linked with the built environment. The occurrence of SBS is associated with humidity, ventilation, moulds and microbial compounds exposure. However, no study has reported the association between indoor microbiome and SBS. In this study, 308 students were surveyed for SBS symptoms from 21 classrooms of 7 junior high schools from Johor Bahru, Malaysia, and vacuum dust from floor, desks and chairs was collected. High throughput amplicon sequencing (16S rRNA gene and ITS region) and quantitative PCR were conducted to characterize the absolute concentration of bacteria and fungi taxa. In total, 326 bacterial and 255 fungal genera were detected in dust with large compositional variation among classrooms. Also, half of these samples showed low compositional similarity to microbiome data deposited in the public database. The number of observed OTUs in Gammaproteobacteria was positively associated with SBS (p = 0.004). Eight microbial genera were associated with SBS (p < 0.01). Bacterial genera, Rhodomicrobium, Scytonema and Microcoleus, were protectively (negatively) associated with ocular and throat symptoms and tiredness, and Izhakiella and an unclassified genus from Euzebyaceae were positively associated with the throat and ocular symptoms. Three fungal genera, Polychaeton, Gympopus and an unclassified genus from Microbotryaceae, were mainly positively associated with tiredness. The associations differed with our previous study in microbial compounds (endotoxin and ergosterol) and SBS in the same population, in which nasal and dermal symptoms were affected. A higher indoor relative humidity and visible dampness or mould in classrooms were associated with a higher concentration of potential risk bacteria and a lower concentration of potential protective bacteria (p < 0.01). This is the first study to characterize the SBS-associated microorganisms in the indoor environment, revealing complex interactions between microbiome, SBS symptoms and environmental characteristics. Topics: Air Pollution, Indoor; Humans; Malaysia; Microbiota; RNA, Ribosomal, 16S; Schools; Sick Building Syndrome | 2021 |
Endotoxin, ergosterol, muramic acid and fungal DNA in dust from schools in Johor Bahru, Malaysia--Associations with rhinitis and sick building syndrome (SBS) in junior high school students.
This paper studied associations between ocular symptoms, rhinitis, throat and dermal symptoms, headache and fatigue in students by ethnicity and in relation to exposure to chemical microbial markers and fungal DNA in vacuumed dust in schools in Malaysia. A total of 462 students from 8 randomly selected secondary schools in Johor Bahru, Malaysia, participated (96% response rate). Dust was vacuumed from 32 classrooms and analysed for levels of five types of endotoxin as 3-hydroxy fatty acids (C10, C12, C14, C16 and C18 3-OH), muramic acid, ergosterol and five sequences of fungal DNA. Multiple logistic regression was applied. Totally 11.9% reported weekly ocular symptoms, 18.8% rhinitis, 15.6% throat and 11.1% dermal symptoms, 20.6% headache and 22.1% tiredness. Totally 21.1% reported pollen or furry pet allergy (atopy) and 22.0% parental asthma or allergy. Chinese students had less headache than Malay and Indian had less rhinitis and less tiredness than Malay. Parental asthma/allergy was a risk factor for ocular (odds ratio=3.79) and rhinitis symptoms (OR=3.48). Atopy was a risk factor for throat symptoms (OR=2.66), headache (OR=2.13) and tiredness (OR=2.02). There were positive associations between amount of fine dust in the dust samples and ocular symptoms (p<0.001) and rhinitis (p=0.006). There were positive associations between C14 3-OH and rhinitis (p<0.001) and between C18 3-OH and dermal symptoms (p=0.007). There were negative (protective) associations between levels of total endotoxin (LPS) (p=0.004) and levels of ergosterol (p=0.03) and rhinitis and between C12 3-OH and throat symptoms (p=0.004). In conclusion, the amount of fine dust in the classroom was associated with rhinitis and other SBS symptoms and improved cleaning of the schools is important. Endotoxin in the school dust seems to be mainly protective for rhinitis and throat symptoms but different types of endotoxin could have different effects. The ethnic differences in symptoms among the students deserve further attention. Topics: Adolescent; Air Pollution, Indoor; Allergens; Asthma; DNA, Fungal; Dust; Endotoxins; Ergosterol; Humans; Hypersensitivity; Inhalation Exposure; Malaysia; Muramic Acids; Rhinitis; Schools; Sick Building Syndrome; Students | 2016 |
Sick building syndrome (SBS) among office workers in a Malaysian university--Associations with atopy, fractional exhaled nitric oxide (FeNO) and the office environment.
There are few studies on sick building syndrome (SBS) including clinical measurements for atopy and fractional exhaled nitric oxide (FeNO). Our aim was to study associations between SBS symptoms, selected personal factors, office characteristics and indoor office exposures among office workers from a university in Malaysia. Health data were collected by a questionnaire (n=695), skin prick test (SPT) (n=463) and FeNO test (n=460). Office settled dust was vacuumed and analyzed for endotoxin, (1,3)-β-glucan and house dust mites (HDM) allergens group 1 namely Dermatophagoides pteronyssinus (Der p 1) and Dermatophagoides farinae (Der f 1). Office indoor temperature, relative air humidity (RH), carbon monoxide (CO) and carbon dioxide (CO2) were measured by a direct reading instrument. Associations were studied by two-levels multiple logistic regression with mutual adjustment and stratified analysis. The prevalence of weekly dermal, mucosal and general symptoms was 11.9%, 16.0% and 23.0% respectively. A combination of SPT positivity (allergy to HDM or cat) and high FeNO level (≥25 ppb) was associated with dermal (p=0.002), mucosal (p<0.001) and general symptoms (p=0.05). Der f1 level in dust was associated with dermal (p<0.001), mucosal (p<0.001) and general (p=0.02) symptoms. Among those with allergy to D. farinae, associations were found between Der f 1 levels in dust and dermal (p=0.003), mucosal (p=0.001) and general symptoms (p=0.007). Office-related symptoms were associated with Der f 1 levels in dust (p=0.02), low relative air humidity (p=0.04) and high office temperature (p=0.05). In conclusion, a combination of allergy to cat or HDM and high FeNO is a risk factor for SBS symptoms. Der f 1 allergen in dust can be a risk factor for SBS in the office environment, particularly among those sensitized to Der f 1 allergen. Topics: Air Pollution, Indoor; Animals; Antigens, Dermatophagoides; Arthropod Proteins; Cysteine Endopeptidases; Humans; Malaysia; Nitric Oxide; Sick Building Syndrome; Skin Tests; Universities | 2015 |