ethylene oxide has been researched along with Prosthesis Durability in 11 studies
Timeframe | Studies, this research(%) | All Research% |
---|---|---|
pre-1990 | 0 (0.00) | 18.7374 |
1990's | 1 (9.09) | 18.2507 |
2000's | 6 (54.55) | 29.6817 |
2010's | 3 (27.27) | 24.3611 |
2020's | 1 (9.09) | 2.80 |
Authors | Studies |
---|---|
Baryeh, KW; Bennett, K; Sochart, DH | 1 |
Iwamoto, M; Kyomoto, M; Oonishi, H; Ueno, M | 1 |
Dybal, J; Fulín, P; Pokorný, D; Slouf, M; Sosna, A; Vacková, T | 1 |
Hansen, TB; Hengst, DM; Homilius, M; Stilling, M; Thomsen, PB | 1 |
Kim, HJ; Koo, KH; Nam, KW; Yoo, JJ; Yoon, KS | 1 |
Lewis, G | 1 |
Digas, G; Kärrholm, J; Nivbrant, B; Röhrl, S; Ström, H; Thanner, J | 1 |
Kondo, S; Kuroki, Y; Kusaba, A; Mori, Y | 1 |
Collier, JP; Mayor, MB; Williams, IR | 1 |
Barbour, PS; Barton, DC; Endo, MM; Fisher, J; Ingham, E; Stone, MH; Tipper, JL | 1 |
Barton, DC; Endo, M; Fisher, J; Ingham, E; Stone, MH; Tipper, JL | 1 |
11 other study(ies) available for ethylene oxide and Prosthesis Durability
Article | Year |
---|---|
The ethylene oxide sterilised Opera acetabular component demonstrates high rates of loosening and revision compared to the gamma irradiated Ogee cup: a cohort study demonstrating potential shortcomings of revision-based registry data.
Topics: Acetabulum; Arthroplasty, Replacement, Hip; Cohort Studies; Ethylene Oxide; Follow-Up Studies; Hip Prosthesis; Humans; Prosthesis Design; Prosthesis Failure; Reoperation; Routinely Collected Health Data | 2023 |
Radiographic and retrieval wear analyses of the first generation highly cross-linked polyethylene cup against a ceramic femoral head.
Topics: Adult; Aged; Aluminum Oxide; Arthroplasty, Replacement, Hip; Ceramics; Cross-Linking Reagents; Ethylene Oxide; Female; Femur Head; Hip Prosthesis; Humans; Male; Materials Testing; Middle Aged; Polyethylene; Prosthesis Design; Prosthesis Failure; Young Adult | 2013 |
[Effect of sterilisation with formaldehyde, gamma irradiation and ethylene oxide on the properties of polyethylene joint replacement components].
Topics: Arthroplasty, Replacement; Comparative Effectiveness Research; Ethylene Oxide; Formaldehyde; Gamma Rays; Humans; Joint Prosthesis; Materials Testing; Polyethylene; Prosthesis Failure; Spectrophotometry, Infrared; Sterilization | 2014 |
Higher wear-rate of third-generation metal-backed Reflection cups with eto-sterilised UHMWPE at a mean 13 years follow-up.
Topics: Adult; Aged; Chromium; Cobalt; Disinfectants; Ethylene Oxide; Female; Follow-Up Studies; Hip Prosthesis; Humans; Male; Middle Aged; Polyethylenes; Prosthesis Design; Prosthesis Failure; Retrospective Studies; Sterilization; Time Factors | 2014 |
Optimal sterilization method for the zirconia/alumina composites used for total hip replacements.
Topics: Aluminum; Arthroplasty, Replacement, Hip; Biocompatible Materials; Dose-Response Relationship, Radiation; Ethylene Oxide; Femur Head; Hip Joint; Humans; Materials Testing; Microbial Sensitivity Tests; Prosthesis Failure; Sterilization; Stress, Mechanical; Surface Properties; Zirconium | 2009 |
Effect of an accelerated aging protocol on viscoelastic properties of UHMWPE.
Topics: Biocompatible Materials; Bone Substitutes; Elasticity; Equipment Failure Analysis; Ethylene Oxide; Gamma Rays; Guidelines as Topic; Hot Temperature; Humans; Knee Prosthesis; Materials Testing; Polyethylenes; Prosthesis Failure; Reproducibility of Results; Sensitivity and Specificity; Sterilization; Stress, Mechanical; Tibia; Time Factors; Viscosity | 2002 |
Increase in early polyethylene wear after sterilization with ethylene oxide: radiostereometric analyses of 201 total hips.
Topics: Adult; Aged; Aged, 80 and over; Ethylene Oxide; Female; Hip Prosthesis; Humans; Male; Middle Aged; Prosthesis Failure; Sterilization | 2003 |
In vivo change of elastic property in polyethylene acetabular components.
Topics: Acetabulum; Arthroplasty, Replacement, Hip; Biocompatible Materials; Disinfectants; Elasticity; Ethylene Oxide; Gamma Rays; Hardness Tests; Hip Prosthesis; Humans; Polyethylene; Prosthesis Failure; Reoperation; Sterilization | 2008 |
The impact of sterilization method on wear in knee arthroplasty.
Topics: Biomechanical Phenomena; Ethylene Oxide; Gamma Rays; Humans; Knee Prosthesis; Oxidation-Reduction; Polyethylenes; Prosthesis Failure; Sterilization | 1998 |
Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene.
Topics: Acetylene; Biomechanical Phenomena; Cross-Linking Reagents; Disinfectants; Equipment Failure Analysis; Ethylene Oxide; Friction; Gamma Rays; Hip Prosthesis; Humans; Materials Testing; Osteolysis; Polyethylenes; Prosthesis Failure; Range of Motion, Articular; Surface Properties | 2001 |
Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses.
Topics: Acetylene; Chromium Alloys; Cobalt; Cross-Linking Reagents; Equipment Failure Analysis; Ethylene Oxide; Femur Head; Friction; Hip Prosthesis; Humans; Materials Testing; Models, Biological; Motion; Polyethylenes; Prosthesis Failure; Quantitative Structure-Activity Relationship; Range of Motion, Articular; Surface Properties; Weight-Bearing | 2002 |