deuterium has been researched along with Water-Electrolyte Imbalance in 4 studies
Timeframe | Studies, this research(%) | All Research% |
---|---|---|
pre-1990 | 0 (0.00) | 18.7374 |
1990's | 0 (0.00) | 18.2507 |
2000's | 2 (50.00) | 29.6817 |
2010's | 2 (50.00) | 24.3611 |
2020's | 0 (0.00) | 2.80 |
Authors | Studies |
---|---|
Bosy-Westphal, A; Chamney, P; Dahlgren, J; Dasgupta, I; Fors, H; Keane, D; Lindley, E; Moissl, U; Müller, MJ; Schaefer, F; Shaheen, I; Tyerman, K; Wabel, P; Wühl, E | 1 |
Agostoni, C; Consolo, S; Consonni, D; Edefonti, A; Fossali, EF; Groothoff, JW; Milani, GP; Oosterveld, MJS; Paglialonga, F; Schierbeek, H; van Goudoever, JB; van Harskamp, D; Vianello, FA | 1 |
Chan, C; Davies, SJ; McIntyre, C; Smith, D; Spanel, P | 1 |
Chan, C; Davies, SJ; McIntyre, CW; Smith, D; Spanel, P | 1 |
1 trial(s) available for deuterium and Water-Electrolyte Imbalance
Article | Year |
---|---|
Combining near-subject absolute and relative measures of longitudinal hydration in hemodialysis.
Topics: Adult; Aged; Body Composition; Breath Tests; Comorbidity; Deuterium; Drinking; Electric Impedance; Feasibility Studies; Female; Humans; Kidney Failure, Chronic; Longitudinal Studies; Male; Mass Spectrometry; Middle Aged; Prospective Studies; Renal Dialysis; Water-Electrolyte Imbalance | 2009 |
3 other study(ies) available for deuterium and Water-Electrolyte Imbalance
Article | Year |
---|---|
Validating the use of bioimpedance spectroscopy for assessment of fluid status in children.
Topics: Adolescent; Body Composition; Body Water; Child; Child, Preschool; Deuterium; Electric Impedance; Female; Healthy Volunteers; Humans; Kidney Failure, Chronic; Male; Monitoring, Physiologic; Renal Dialysis; Water-Electrolyte Imbalance | 2018 |
Bioimpedance Spectroscopy Imprecisely Assesses Lean Body Mass in Pediatric Dialysis Patients.
Topics: Adolescent; Body Composition; Body Weight; Child; Child, Preschool; Deuterium; Electric Impedance; Female; Humans; Male; Nutritional Status; Renal Dialysis; Renal Insufficiency, Chronic; Reproducibility of Results; Saliva; Spectrum Analysis; Water-Electrolyte Imbalance | 2018 |
A non-invasive, on-line deuterium dilution technique for the measurement of total body water in haemodialysis patients.
Topics: Aged; Body Water; Breath Tests; Deuterium; Electric Impedance; Female; Humans; Indicator Dilution Techniques; Kidney Failure, Chronic; Male; Mass Spectrometry; Middle Aged; Renal Dialysis; Reproducibility of Results; Sampling Studies; Sensitivity and Specificity; Water-Electrolyte Imbalance | 2008 |